Kennel Specification.pdf
PDF 2 MB Posted
- Attached to
- Adoption Room Renovation
- Solicitation number
- 82071
- Issued by
- Hanover County, Arlington CDP, Virginia
About this file
This document appears to be a set of technical specifications for a kennel system for the Hanover County Animal Control project. The specifications outline the detailed design and dimensions of the kennel room, including wall-to-wall measurements, gutter dimensions, and required accessories such as support posts, rest benches, and top covers. The project number is A236616 and the document is in Phase 01, Revision 7. The kennel system is to be provided by Midmark, with the dimensions and finishes clearly specified. No information is provided on the procurement process, timeline, pricing, or funding source for this project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Adoption Room Renovation.pdf | ||
| Kennel Specification.pdf | ||
| Adoption Room Renovation.pdf | ||
| Kennel Specification.pdf | ||
| Adoption Room Renovation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
4/16Drawing Template: - Revision: - Change Order: -
Signed Drawings Required To Process Order
(Signature) (Date)
WALL TO WALL 378" [31'-6"]
W
AL
L
TO
W
AL
L
[2 9'
-2
40"
38"
150"
PLAN
DIRECTIONS
W E N
S
WALL TO GUTTER 15'-6" WALL TO GUTTER 15'-6"
GUTTER 6"
VERIFY SLOPEVERIFY SLOPE
Version: 1
Field Measurements Approved
Floor Plan View
Kennel Room
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
5/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Signed Drawings Required To Process Order
(Signature) (Date)
72.25"
60.25"73.00" 72.25"
Version: 1
Room Plan View
RBXX00000-XXX | Rest Bench QTY: 8
TCXX-XX00000-XXX | Top Cover QTY: 8
6/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Kennel Room
Signed Drawings Required To Process Order
(Signature) (Date)
FRP
SG37-RNNDNYW-245
FRP
SG37-RNNDNYP-245
FRP
SG37-RNNDNYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYW-245
34.75"
36.50"
34.75"
37.00"
34.75"
37.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
47.50"
76.38"
350.00"
Version: 1
Accessories:
245-Sky, 929-Stainless Steel
350" x 73" x 75"
Finish:
Dimensions:
Threshold:
Note: Field Measurement Approved
Not Included www.midmark.com
Phone: 1-800-MIDMARK
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
Kennel Room 7/16Drawing Template: - Revision: - Change Order: -
Signed Drawings Required To Process Order
(Signature) (Date)
Kennel 3D View
Signed Drawings Required To Process Order
(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Kennel Room
GPSK-8164000-XXX | Support Post QTY: 1
RBXX00000-XXX | Rest Bench QTY: 6
TCXX-XX00000-XXX | Top Cover QTY: 6
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
8/16Drawing Template: - Revision: - Change Order: -
FRP FRP
SF48-LRNDSYW-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
45.75" [30.25" Gate]
47.63"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
50.88"
76.38"
290.50"
Threshold: Not Included
290.5" x 73" x 75"
Version: 1
Dimensions:
Finish:
Field Measurement ApprovedNote:
245-Sky, 929-Stainless Steel
Accessories:
GPSK-8164000-XXX | Support Post QTY: 1
RBXX00000-XXX | Rest Bench QTY: 6
TCXX-XX00000-XXX | Top Cover QTY: 6
Kennel Room
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
9/16Drawing Template: - Revision: - Change Order: -
Signed Drawings Required To Process Order
(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
FRPFRP
SF48-RLNDSYW-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
FRPFRP
SF48-RLNDSYP-245
45.75" [30.25" Gate]
47.63"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
50.88"
76.38"
290.50"
Finish:
Not Included
Field Measurement Approved
Dimensions:
245-Sky, 929-Stainless Steel
Threshold:
Version: 1
Note:
Accessories:290.5" x 72.25" x 75"
(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
10/16Drawing Template: - Revision: - Change Order: -
Kennel Room
(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
11/16Drawing Template: - Revision: - Change Order: -
GPSK-8164000-XXX | Support Post QTY: 2
RBXX00000-XXX | Rest Bench QTY: 5
TCXX-XX00000-XXX | Top Cover QTY: 5
Kennel Room
Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
FRP FRP
SF48-LRNDSYP-245
45.75" [30.25" Gate]
50.88"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
48.00"
45.75" [30.25" Gate]
50.88"
76.38"
245.75"
Dimensions:
Not Included
Version: 1
Finish:
Field Measurement Approved
245.75" x 61" x 75"
Note:
Accessories:
Threshold:
245-Sky, 929-Stainless Steel
Kennel Room www.midmark.com design@midmark.com Phone: 1-800-MIDMARK
Signed Drawings Required To Process Order
(Signature) (Date)
12/16Drawing Template: - Revision: - Change Order: -
14/16Drawing Template: - Revision: - Change Order: -
Sani-Kennel Details
* The slope information is for kennel systems using Midmark Sani-T or Sani-L systems only.
* Customization will be required if the flooring exceeds the 2” slope maximum panel allowance.
* Midmark is not responsbile for replacing products modified in the field.
Disclaimers www.midmark.com design@midmark.com
Phone: 1-800-MIDMARK
Floor Slope Wall/Floor Coving
15/16Drawing Template: - Revision: - Change Order: -
Stainless Steel
Stainless Steel
Back Panel
Stainless Steel
Side Panel
75.00"
47.25"
75.00"
60.00"
Version: 1
CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.
Sani-Kennel Panel Views www.midmark.com
16/16Drawing Template: - Revision: - Change Order: -
Stainless Steel
Side Panel
75.00"
72.00"
Version: 1
CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.
www.midmark.com design@midmark.com
Sani-Kennel Panel Views
File details come from the government source that posted it. Updated .