About this file
The document is a photometric plan for the Kellogg Park Nature Center, prepared by AAA Lighting for LC (Lighting Consultants), detailing the illumination design for an outdoor area. The plan includes a site layout with Garden Lane Drive and Nursery Road, featuring an existing pond and a central structure. The luminaire schedule indicates two types of light fixtures: 2 BL3 units and 6 PL3 units, with specific model numbers, lumen outputs, and light loss factors. The photometric analysis provides detailed illuminance calculations for drive and sidewalk areas, showing average, maximum, and minimum foot-candle measurements.
The photometric plan demonstrates precise lighting coverage, with green overlay circles indicating the light distribution patterns across the site. The luminaire schedule reveals technical specifications such as LED configuration (24LED and 36LED), color temperature (40K), and voltage requirements. The calculations show careful consideration of lighting uniformity, with drive illuminance ranging from 0.2 to 2.6 foot-candles and sidewalk illuminance between 2.5 and 6.2 foot-candles. The comprehensive approach suggests a professional-grade lighting design intended to provide consistent, functional illumination for the park's pedestrian and vehicular areas.
View the file
Other files for this state and local contract opportunity
Show all 46
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D ra w n
B y
C h e c k e d B y
S c a le
Page M of 1
D a te :1
/3
/2
G L
R D
−K el lo g P ar k−
C −O p t2
−1
.A
G I
R o b e rt
D e W e e s e L C
I E
S
R o b e rt
D e W e e s e L C
I E
S
Robert DeWeese, LC, IES
K e llo g P a rk
-O p ti o n
Luminaire Schedule
Symbol Qty Label Arrangement
Calculation Summary
Label
Description Tag LLF Luminaire
Lumens
Luminaire
Watts
Total
Watts
CalcType Units Avg Max Min Avg/Min Max/Min
Drive-Pkg Illuminance
2 BL3 Single USA # BDAR5-AR-FR2-24LED-NW-
350mA-40K VOLT-FINISH
0.890 1451 26.4 52.8
Fc 1.5 2.6 0.2 7.55 13.00
Sidewalk Illuminance Fc 4.0 6.2 2.5 1.61
6 PL3 Single USA # DS6S-PLED-III-M-36LED-
700mA-40K-UNV-1-FINISH
0.890 10154 82.6 495.6
2.48
PL3 PL3
PL3
PL3
PL3
BL3
BL3
PL3
2.5 2.7 3.0 3.4 4.0 4.4 5.4 6.0 4.7
2.5 2.7 3.0 3.4 3.9 4.4 5.5 6.2 4.7
2.0 2.5 2.5 2.2 1.9 1.7
2.6 2.4 2.3 2.0 1.8 1.7
2.1 2.5 2.4 2.3 2.1 2.0 2.0
1.4 2.1 2.2 2.2 2.1 2.1 2.1
0.8 1.6 1.9 2.0 2.0 2.0 2.1
0.6 1.3 1.7 1.8 1.8 1.9 1.9
0.9 1.0 1.0 0.8
1.3 1.3
1.8 1.6
2.1 1.8
2.2 2.0
1.9 2.4 2.3 2.1
1.3 2.2 2.2 2.1 1.7
1.4 2.2 2.3 2.2 1.8
0.6 1.2 1.6 1.7 1.7 1.7 1.6
0.6 1.3 1.6 1.7 1.6 1.5 1.4
0.9 1.6 1.7 1.7 1.6 1.4 1.2
1.5 2.0 1.9 1.8 1.5
1.9 1.7 1.4
1.8 1.6
1.8 1.6 1.4
0.2 0.4 1.0 1.8 1.5 0.8 0.4 0.3 0.4 0.6 1.2 1.0 1.4 1.3 1.2
0.6 1.0 1.5 2.0 2.0 1.5 1.1 1.0 1.1 1.3 1.8 1.3 1.2 1.3 1.3 1.2
0.8 1.1 1.4 1.8 1.8 1.9 1.5 1.4 1.3 1.3 1.5 1.7 1.9 1.8 1.7 1.2 1.2 1.2 1.2
0.8 1.0 1.2 1.4 1.5 1.6 1.5 1.3 1.3 1.3 1.4 1.6 1.6 1.5 1.4 1.1 1.1 1.1
0.6 0.8 0.9 1.1 1.2 1.2 1.2 1.1
0.5 0.6 0.7 0.8 0.8 0.9