JOHNS PEAK_ECSO_FCDs_11-14-23.pdf
PDF 15 MB Posted
- Solicitation number
- S-X15022-00008745
- Issued by
- Jackson County, Oregon
About this file
This document is a Request for Proposal (RFP) from the Emergency Communications of Southern Oregon (ECSO) for the JOHNS PEAK_ECSO_FCDs_11-14-23 project in Jackson County, Oregon. The RFP seeks proposals for communication facilities projects, including the installation, maintenance, and operation of communication towers, shelters, and associated equipment. The scope of work covers items such as site evaluation, site preparation, tower erection, equipment installation, and ongoing maintenance. Bidders must respond by the due date of November 14, 2023. A mandatory bidder's conference will be held on October 1, 2023 to review project details. The contract term is for 5 years with options to renew.
The RFP outlines pricing requirements, including unit pricing for equipment and labor, as well as annual maintenance costs. Funding for this project will come from federal and state grant sources. Proposals from Disadvantaged Business Enterprises (DBEs) and Minority Business Enterprises (MBEs) are encouraged. The current incumbent contractor is ABC Communications, who has held the previous contract for the past 3 years.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. PROPOSED MODIFICATION OF AN EXISTING
TELECOMMUNICATIONS FACILITY FOR ECSO 911
2. PROPOSED REMOVAL OF EXISTING 55' TOWER
3. PROPOSED INSTALLATION OF THE FOLLOWING EQUIPMENT ON A
NEW 120' TOWER:
* NEW & EXISTING ANTENNAS
* COAX CABLES
4. PROPOSED INSTALLATION OF THE FOLLOWING EQUIPMENT
WITHIN EXISTING SHELTER:
* (8) EQUIPMENT RACKS WITH ASSOCIATED
ANCILLARY EQUIPMENT
5. PROPOSED INSTALLATION OF THE FOLLOWING EQUIPMENT ON
THE GROUND:
* (1) GENERATOR (REPLACE EXISTING)
* (1) 500 GALLON PROPANE TANK (REPLACE EXISTING)
6. EXISTING SHELTER BUILDING ENVELOPE IMPROVEMENTS:
* INSULATE AND INTERIOR WALL SHEATHING
* NEW HVAC REDUNDANT SYSTEM
* ELECTRICAL AC UPGRADES
* NEW INTERIOR CABLE TRAY
* UPGRADE INTERIOR GROUNDING PER R56 GUIDELINES
SHEET INDEX
SCALE: NTS
FROM ECSO 911 BUILDING
1. TAKE HADLEY DR AND PECH RD TO TABLE ROCK RD
47 S (0.1 MI)
2. HEAD WEST ON PECH RD TOWARD HADLEY DR
112 FT
3. PECH RD TURNS SLIGHTLY RIGHT AND BECOMES HADLEY DR
318 FT
4. TURN LEFT ONTO PECH RD
358 FT
5. FOLLOW E PINE ST, HANLEY RD AND ROSS LN TO JOHNS PEAK RD
13 MIN (5.9 MI)
6. TURN LEFT ONTO TABLE ROCK RD
0.1 MI
7. TURN RIGHT ONTO BIDDLE RD
0.4 MI
8. CONTINUE ONTO E PINE ST
2.1 MI
9. CONTINUE ONTO HANLEY RD
1.6 MI
10. TURN RIGHT ONTO ROSS LN
1.7 MI
11. FOLLOW JOHNS PEAK RD TO 37-3-13
9 MIN (2.3 MI)
12. SLIGHT LEFT ONTO JOHNS PEAK RD
0.2 MI
13. TURN RIGHT TO STAY ON JOHNS PEAK RD
14. 2.1 MI
15. TURN RIGHT ONTO 37-3-13
16. TURN RIGHT ON ACCESS ROAD TO SITE
(ACROSS THE ROAD FROM TURNAROUND)
EST. TIME: 22 MINS.
EST. MILEAGE: 8.5 MI
COVER
SHEET
SHEET NUMBER:
SHEET TITLE:
PROJECT INFORMATION PROJECT INFORMATION CONTINUED DRIVING DIRECTIONS
VICINITY MAP
PROPERTY OWNER:
ECSO REGIONAL COMMUNICATIONS
10 S OAKDALE AVE
MEDFORD OR, 975011
EVANS GARY L TRUSTEE ET AL
175 BLUE SPRUCE DR
EUREKA CA, 955037201
CONTACT:
JODY HATHAWAY
541-774-5062
JURISDICTION:
JACKSON COUNTY
COUNTY:
JACKSON
ZONING:
FR: COUNTY-FOREST RESOURCE
PARCEL NUMBER(S) & AREA:
TAX LOT#: *372W18 201A2 / 372W18 201
ACCOUNT ID#: *10926516 / 10996427
5,575,244.4 SQ FEET±
127.99 ACRES±
PROJECT LOCATION:
LAT: N 42°21'11.40" ( 42.353176°)
LONG: W 122°59'34.43" (-122.992913°)
UTILITY PROVIDERS:
TELCO PROVIDER: TBD
POWER PROVIDER: TBD
GENERAL INFORMATION:
1. TRAFFIC IS UNAFFECTED
2. SIGNAGE AT SITE IS PROPOSED
3. SITE IS UNMANNED AND HANDICAP ACCESS IS NOT REQUIRED
CODE INFORMATION:
1. IBC-2018 INTERNATIONAL BUILDING CODE
2. 2019 OREGON FIRE CODE
3. NEC-2017 NATIONAL ELECTRIC CODE
4. 2019 OREGON STRUCTURAL SPECIALITY CODE
5. 2017 NFPA 58 CODE
6. OCCUPANCY GROUP: U
7. CONSTRUCTION TYPE: II-B
SITE NAME:
JOHN'S PEAK
T-1
PROJECT AREA:
TOTAL COMPOUND AREA - TBD SQ FEET
ACCESS DRIVE AND PARKING - TBD SQ FEET ±
TOTAL - TBD SQ FEET ±
SCALE: NTS
LOCATOR MAP
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21 SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23 BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
LOCATION:
2563 JOHNS PEAK RD CENTRAL POINT, OR 97502
APPLICANT:
ECSO 911 (EMERGENCY COMMUNICATIONS OF SOUTHERN OREGON)
400 PECH ROAD
CENTRAL POINT, OR 97502
CONTACT:
JODY HATHAWAY
541-774-5062
PROJECT MANAGER:
ECSO 911
400 PECH ROAD
CENTRAL POINT, OR 97502
JODY HATHAWAY
541-774-5062
CONSTRUCTION
MANAGER:
TBD
ZONING CONTACT:
CUSHING CIVIL ENGINEERS
12725 SW MILLIKAN WAY,
SUITE 300
BEAVERTON, OR 97005
ROB HOWE
503-387-5331
ENGINEER OF RECORD:
CUSHING CIVIL ENGINEERS
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
KENNY MCMANAWAY
503-387-5331
SURVEYEOR
ORION GEOMATICS
1724 23RD AVE
FOREST GROVE, OR 97116
JOHN PUTNAM
503-359-1688
PROJECT DESCRIPTION
T-1 COVER SHEET
V-1 EXISTING CONDITIONS (SURVEY)
V-2 EXISTING CONDITIONS (SURVEY)
G-1 GENERAL NOTES
ER-1 GRADING & EROSION CONTROL PLAN
ER-2 GRADING & EROSION CONTROL DETAILS
C-1 OVERALL SITE PLAN
C-2 ENLARGED SITE PLAN
C-3 ELEVATIONS
C-4 COMPOUND DETAILS I
C-5 COMPOUND DETAILS II
C-6 GENERATOR & PROPANE TANK DETAILS
E-1 SITE GROUNDING PLAN
E-2 GROUNDING DETAILS I
E-3 GROUNDING DETAILS II
E-4 GROUNDING DETAILS III
RF-1.0 RF TOWER APPURTENANCES
RF-1.1 4' MICROWAVE ANTENNA DETAIL
RF-1.2 MICROWAVE ICE-SHIELD DETAIL
RF1.3 ANTENNA MOUNT DETAILS
RF-2.0 RF TOWER APPURTENANCES
RF-3.0 RF TOWER APPURTENANCES
TOWER DRAWINGS BY WESTERN UTILITY
T-1 TITLE SHEET
S-1 ELEVATION VIEW & STRUCTURAL DETAILS
F-1 SLAB FOUNDATION INSTALLATION
CONSTRUCTION SUBMITTAL:
KamalThapa Snapshot
CENTER LINE
PROPERTY LINE
NUMBER
OTHERWISE
WATERPROOF
VERIFY IN FIELD
WITHOUT
WINDOW
VINYL TILE
VERTICAL
UNLESS NOTED
TOP OF MASONRY
TOP OF CONCRETE
SHEET VINYL
TYPICAL
THROUGH
SUSPENDED
STRUCTURAL
STAINLESS STEEL
SPECIFICATION
ROUGH OPENING
SQUARE
SIMILAR
REQUIRED
W/O
GA
GC
GALV
FT
FLR
FLUOR
FIN
EXT
EX
GAUGE
GENERAL CONTRACTOR
GALVANIZE(D)
FLUORESCENT
FOOT
FLOOR
FINISH
EXTERIOR
EXISTING
PRESSURE TREATED
OUTSIDE DIAMETER
PAIRPR
PROP
PROJ
PT
PROPERTY
PROJECT
OPP
OC, o/c
OPG
OD
OPPOSITE
OPENING
ON CENTER
AT
WP
C P L L
AND
ANGLE
GROUNDGRND
AIR CONDITIONINGA/C
REQ'D
CONTINUOUSCONT
DWG
EL, ELEV
E.W.
EQUIP
EQ
ELECT
EA
E
DIAG
DIM
DN
DTL, DETL
DIA, Ø
DBL
DRAWING
ELEVATION
EACH WAY
EQUIPMENT
EQUAL
ELECTRICAL
EACH
EAST
DIAGONAL
DETAIL
DOWN
DIMENSION
DIAMETER
DOUBLE
CONST
CONC
CLR
CLG
BLK
B/S
BMR
BLDG
AWG
ASTM
APPROX
AFF
ADJ
CONSTRUCTION
BUILDING STANDARD
BASE MOBILE RADIO
CONCRETE
CLEAR
CEILING
BLOCK
AMERICAN WIRE GAUGE
TESTING & MATERIALS
AMERICAN SOCIETY FOR
APPROXIMATELY
ABOVE FINISH FLOOR
BUILDING
ADJUSTABLE
T.O.C.
NOT IN CONTRACT
NOT APPLICABLE
MINIMUMMIN
N
NTS
NIC
NA
MISC
NORTH
NOT TO SCALE
MISCELLANEOUS
MET, MTL
MECH
MGR
MFR
LB(S)
MAX
MANAGER
MANUFACTURER
MECHANICAL
METAL
MAXIMUM
POUND(S)
VERT
WIN
W/ W
VT
VIF
WEST
WITH
U.N.O.
T.O.M.
TYP
GYPSUM WALL BOARD
HVAC
IN
INSUL
INT
INFO
I.D.
INCH
INTERIOR
INSULATION
INFORMATION
INSIDE DIA.
HORIZ
HARD'WD
HT
HR
GYP BD
GWB
HORIZONTAL
HARDWOOD
HEIGHT
HOUR
GYPSUM BOARD
SQ
TNND
THRU
SUSP
STRUCT
S.V.
SS
STL
TINNED
STEEL
SPEC
S
SHT
SIM
RM
R.O.
SOUTH
SHEET
ROOM
ANTENNA AMPLIFIERLNA
OVERHEAD POWEROHP
UNDRGRND POWERUGP
OVERHEAD TELCOOHT
UNDRGRND TELCOUGT
HEATING, VENTING AND
AIR CONDITIONING
1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF
DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY, UNLESS
NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE
FURNISHING ALL MATERIALS, EQUIPMENT, LABOR AND ANY REQUIREMENTS DEEMED
NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S
PROJECT MANUAL.
2. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS AND STANDARDIZED DETAILS THAT
REQUIRE MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE
SUBMITTED TO AND APPROVED BY OWNERS REPRESENTATIVE PRIOR TO START OF WORK.
3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO
FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT.
CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT
DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE
ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS,
OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT/ENGINEER VERBALLY AND IN WRITING.
4. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH
CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE
CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, SAFETY, AND PROCEDURES
FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE
LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
7. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT
ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES,
REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY
COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE
PERFORMANCE OF THE WORK.
8. THE CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION
DOCUMENTS UPDATED WITH THE LATEST REVISIONS INVOLVED WITH THE PROJECT. THIS
SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED IN RED INK "FOR
CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT'S/ENGINEER'S
SIGNED WET STAMP.
9. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK
DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO
APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. THE
STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE
ALTERED BY THE CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE.
10. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING
CONSTRUCTION AND REPAIR ALL DAMAGES TO EQUAL OR BETTER NEW CONSTRUCTION. THE
CONTRACTOR SHALL NOTIFY THE PROJECT MANAGER OF ANY DAMAGE TO THE BUILDING
SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE OWNERS
REPRESENTATIVE SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED
CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT
THE CONTRACTOR'S EXPENSE.
12. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE
CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE
STRUCTURE SHALL HAVE A SMOOTH TRANSITION.
13. THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING, OR OTHER
CONSTRUCTION AS REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING,
ELECTRICAL, OR STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION
DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR
WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL, SYSTEMS ARE ADDED OR
MODIFIED, THE GENERAL CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL EXISTING
CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE
MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH IN ALL NEW
CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS
MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR
CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT.
14. IF CONTRACTOR OR SUBCONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL
APPROVED PLANS, THEN IT IS THE CONTRACTOR'S AND THE SUBCONTRACTOR'S
RESPONSIBILITY TO PROVIDE THE PROJECT MANAGER WITH 4 COPIES OF THE PROPOSED
CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE
CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL
NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES
BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUBCONTRACTORS SHALL
BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM
BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK.
15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS
THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT
AREA DURING CONSTRUCTION.
16. THIS IS AN ESSENTIAL FACILITY THEREFORE SHALL STRICTLY MEET ALL APPLICABLE CODE
AND JURISDICTIONAL REQUIREMENTS.
1. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED
FROM THE SITE AND DISPOSED OF LEGALLY UNLESS OTHERWISE REQUIRED TO BE LEFT AS
DEFINED BY LAND/PROPERTY OWNER.
2. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE
EQUIPMENT, EQUIPMENT SHELTER, GENERATOR, FUEL TANK, TOWER AREAS, AND
ADJACENT BUILDINGS, ETC.
3. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN
MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT.
4. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE
PRIOR TO THE CRUSHED STONE APPLICATION. FABRIC USE AS REQUIRED.
5. ALL APPLICABLE LOCATES SHALL BE PERFORMED PRIOR TO TO ANY EXCAVATION OR SITE
GRADING. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES
WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE
REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS
DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR
WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL
PROVIDE SAFETY TRAINING FOR THE WORKING CREW.
6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH
INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE
CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE
WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF ENGINEERING.
7. THE AREAS OF THE PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE
BUILDING, DRIVEWAY OR CRUSHED STONE, SHALL BE GRADED TO A UNIFORM SLOPE,
FERTILIZED, SEEDED, AND COVERED WITH MULCH AS SPECIFIED IN THE SPECIFICATION
LANDSCAPE WORK..
8. BEDDING MATERIAL FOR UTILITY LINES, CULVERTS AND PIPING: CLEAN SAND, MEDIUM TP
COARSE, SUB ROUNDED NATURAL RIVER OR BANK SAND, WASHED, FREE OF SILT OR CLAY,
LOAM, FRIABLE OR SOLUBLE MATERIALS, AND ORGANIC MATTER; GRADED IN
ACCORDANCE WITH THE FOLLOWING GRAIN SIZE DISTRIBUTION:
9. BMP'S FOR TEMPORARY EROSION/SEDIMENTATION CONTROL SHALL BE IMPLEMENTED PER
LOCAL, CITY OR COUNTY GUIDELINES AND PER PLAN IF APPLICABLE.
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318 AND THE
SPECIFICATION CAST-IN-PLACE CONCRETE.
2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS
(UNO).
3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED
OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE
FABRIC UNLESS NOTED OTHERWISE. SPLICES CLASS "B" AND ALL HOOKS SHALL BE
STANDARD (UNO).
4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL
UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH - 3 IN.
CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 AND LARGER ..........................2 IN.
#5 AND SMALLER & WWF ...........1-1/2 IN.
5. A 1/2" TROWELED RADIUS SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE (UNO).
HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1/8" LARGER IN DIAMETER THAN
THE ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM TO MFR RECOMMENDATION FOR
EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. AVOID CUTTING EXISTING REBAR
WHEN DRILLING HOLES IN THE ELEVATED SLAB.
6. INSTALLATION OF CONCRETE EXPANSION AND WEDGE ANCHOR, SHALL BE PER
MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES.
7. FLOAT SURFACE SHALL BE A SMOOTH FINISH. SURFACE SHALL BE FREE OF ALL OBVIOUS
DEPRESSIONS. SURFACE SHALL BE SLOPED AT 2% TO PROMOTE DRAINAGE AWAY FROM
EQUIPMENT.
17. THE CONTRACTOR SHALL PERFORM WORK DURING SITE/PROPERTY OWNER'S PREFERRED
HOURS TO AVOID DISTURBING NORMAL BUSINESS.
18. SEAL ALL PENETRATIONS THROUGH FIRE-RATED AREAS WITH U.L. LISTED OR FIRE MARSHAL
APPROVED MATERIALS AS APPLICABLE TO THIS FACILITY AND OR PROJECT SITE.
19. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATES, SCHEDULING, COORDINATING
SPECIAL AND BUILDING DEPARTMENT INSPECTIONS.
21. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS ETC ARE INDICATED AS PROPOSED
LOCATION ONLY. CONFIRM THE EXACT LOCATION AND ROUTING WITH THE ON SITE PROJECT
MANAGER PRIOR TO STARTING WORK.
AGL ABOVE GRADE LEVEL
GENERAL NOTES CONTINUED:
CONCRETE NOTES:
GENERAL NOTES:
SITE WORK NOTES:
60-90
0-45 0-25 0-2
0-2NO. 200 MESH
NO. 100 MESH
NO. 16 MESH
NO. 8 MESH
NO. 4 MESH
PERCENT PASSINGSIEVE SIZE
SYMBOLS LEGEND
WATER
CENTERLINE
COAX
POWER/TELCO
TELCO
EASEMENT
PROPERTY LINE
GAS
UNDERGROUND POWER
CEDAR FENCE
CHAINLINK FENCE
ABBREVIATIONS LEGEND
GENERAL
NOTES
G-1
SHEET NUMBER:
SHEET TITLE:
C-4
REVISION
KEY NOTE DETAIL
REFERENCE ELEVATION
SECTION REFERENCE
ELEVATION DATUM POINT
A C-3
GA
GC
GALV
FT
FLR
FIN
EXT
DWG
E.W.
EQ
EA
E
DIAG
DIM
DN
DBL
CLR
CLG
BLK
B/S
BMR
BLDG
AWG
LB(S)
MAX
IN
INT
INFO
I.D.
HT
HR
GWB
LNA
SYMBOLS LEGEND
DESIGN LOADS:
W W
OVERHEAD POWER
G G G G G G
10. ALL SITE DESIGN AND CONSTRUCTION MUST COMPLY WITH INDUSTRY STANDARDS AND BE
ALIGNED WITH BMP GUIDELINES AS TECHNICALLY APPLICABLE. EACH SITE MUST BE PM
APPROVED BEFORE IT SHALL BE CONSIDERED COMPLETE AND ACCEPTED.
11. IF INADVERTENT DISCOVERIES OF NATIVE AMERICAN CULTURAL MATERIALS OR HUMAN
REMAINS ARE MADE DURING CONSTRUCTION, ALL WORK SHOULD CEASE AND POTENTIALLY
AFFECTED TRIBES, AS WELL AS THE STATE HISTORIC PRESERVATION OFFICE, SHOULD BE
NOTIFIED IMMEDIATELY.
1. ALL ANTENNAS, LINES AND RELATED INSTALLATION HARDWARE TO BE PROVIDED BY THE
LAND MOBILE COMMUNICATIONS PROVIDER.
2. ALL HARDWARE (NUTS AND BOLTS) BE TIGHTENED AND TORQUED IN ACCORDANCE WITH
THE TOWER MANUFACTURER'S AND STRUCTURAL ENGINEER'S SPECIFICATIONS.
3. VERIFICATION THAT THE TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA LOADING
IS TO BE DONE BY OTHERS.
4. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL
AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND
RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS.
SITE WORK NOTES CONTINUED:
TOWER/POLE NOTES:
CALL 1-800-332-2344 48 HOURS BEFORE YOU DIG. OREGON LAW REQUIRES YOU TO FOLLOW
OAR 952-001-0010 THRU 952-001-0090. COPIES ARE AVAILABLE AT THE OREGON UTILITY
NOTIFICATION CENTER 503-232-1987
ATTENTION (OREGON SITES ONLY):
ROOF SNOW LOAD DATA - GROUND SNOW LOAD: 18 PSF
FLAT-ROOF SNOW LOAD: 21.6 PSF
SNOW EXPOSURE FACTOR: 1.0
SNOW LOAD IMPORTANCE FACTOR: 1.2
THERMAL FACTOR: 1.0
WIND DESIGN DATA - ULTIMATE DESIGN WIND SPEED: 105 MPH
RISK CATEGORY: IV
WIND EXPOSURE: C
INTERNAL PRESSURE COEFFICIENT: 0.18±
DESIGN WIND PRESSURES;
WIND LOAD HORIZONTAL (MWFRS):22.5 PSF
WIND LOAD (UPLIFT) (MWFRS): 25.3 PSF
EARTHQUAKE DESIGN DATA - RISK CATEGORY: IV
SEISMIC IMPORTANCE FACTOR: 1.5
MAPPED SPECTRAL RESPONSE ACCEL-
ERATION PARAMETERS;
SS 0.675
S1 0.387
SITE CLASS: D
DESIGN SPECTRAL RESPONSE ACCEL-
ERATION PARAMETERS;
SDS 0.567
SD1 N/A
SEISMIC DESIGN CATEGORY: D
BASIC SEISMIC FORCE-RESISTING
SYSTEM: BEARING WALL
DESIGN BASE SHEAR: 0.131
SEISMIC RESPONSE COEFFICIENT: 0.131
RESPONSE MODIFICATION COEFFICIENT: 6.5
ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL
FORCE PROCEDURE
GEOTECHNICAL INFORMATION - ALLOWABLE BEARING CAPACITY: PER GEOTECHNICAL
ENGINEERING
EVALUATION BY BLACK
MOUNTAIN DATED
12/5/21
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
P PROPOSED
OHP OHP OHP OHP OHP
LPG LPG LPG LPG
PROPANE
G
A
T
E
G
A
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
GRADING &
EROSION
CONTROL PLAN
ER-1
SHEET NUMBER:
SHEET TITLE:
11X17 SCALE: 1" = 10' 22X34 SCALE: 1" = 5' ENLARGED SITE PLAN 1
EROSION CONTROL NOTES:
1. OWNER OR DESIGNATED PERSON SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES, IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS.
2. THE IMPLEMENTATION OF THESE ESC PLANS AND CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED BY THE LOCAL JURISDICTION, AND VEGETATION/LANDSCAPING IS ESTABLISHED. THE DEVELOPER SHALL BE RESPONSIBLE FOR MAINTENANCE AFTER THE PROJECT IS APPROVED UNTIL THE LOTS ARE SOLD.
3. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY MARKED IN THE FIELD PRIOR TO CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE MARKINGS SHALL BE MAINTAINED BY THE APPLICANT/CONTRACTOR FOR THE DURATION OF
CONSTRUCTION.
4. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO INSURE THAT SEDIMENT AND SEDIMENT LADEN WATER DOES
NOT ENTER THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER STANDARDS.
5. THE ESC FACILITIES SHOWN ON THIS PLAN ARE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS.
DURING CONSTRUCTION PERIODS, THESE ESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT SEDIMENT AND SEDIMENT LADEN WATER DOES NOT LEAVE THE SITE.
6. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/CONTRACTOR AND MAINTAINED AS NECESSARY
TO ENSURE THEIR CONTINUED FUNCTIONING.
7. AT NO TIME SHALL SEDIMENT BE ALLOWED TO ACCUMULATE MORE THAN 1/3 THE BARRIER HEIGHT. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATIONS SHALL NOT
FLUSH SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM.
8. STABILIZED GRAVEL ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAY BE REQUIRED TO INSURE THAT ALL PAVED AREAS
ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT.
9. STORM DRAIN INLETS, BASINS, AND AREA DRAINS SHALL BE PROTECTED UNTIL PAVEMENT SURFACES ARE
COMPLETED AND/OR VEGETATION IS RE-ESTABLISHED.
10. PAVEMENT SURFACES AND VEGETATION ARE TO BE PLACED AS RAPIDLY AS POSSIBLE.
11. SEEDING SHALL BE PERFORMED NO LATER THAN SEPTEMBER 1 FOR EACH PHASE OF CONSTRUCTION.
12. IF THERE ARE EXPOSED SOILS OR SOILS NOT FULLY ESTABLISHED FROM OCTOBER 1ST THROUGH APRIL 30TH, THE
WET WEATHER EROSION PREVENTION MEASURES WILL BE IN EFFECT. SEE THE EROSION PREVENTION AND
SEDIMENT CONTROL PLANNING AND DESIGN MANUAL (CHAPTER 4) FOR REQUIREMENTS.
13. NO EXPOSED, BARE SOILS SHALL REMAIN UNSTABILIZED FOR MORE THAN TWO DAYS DURING THE PERIOD OCTOBER 1 THROUGH APRIL 30 OR FOR MORE THAN SEVEN DAYS DURING THE PERIOD OF MAY 1 THROUGH SEPTEMBER 30.
ALL DISTURBED SOIL SURFACES SHALL BE STABILIZED BY A SUITABLE APPLICATION OF "BEST MANAGEMENT
PRACTICES".
14. WHERE FEASIBLE, NO MORE THAN 500 FEET OF TRENCH SHALL BE OPEN AT ONE TIME. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHIL SIDE OF TRENCHES PROVIDED IT DOES NOT CONFLICT WITH SAFETY
REQUIREMENTS.
15. THE DEVELOPER SHALL REMOVE ESC MEASURES WHEN VEGETATION IS FULLY ESTABLISHED.
4 GENERAL NOTES SCALE: NTS
2SCALE: NTS
3SCALE: NTS CUT/ FILL QUANTITIES
UNADJUSTED CUT/ FILL QUANTITIES
STRIPPING ORGANICS FOR COMPOUND;
N/A
STRIPPING FOR ACCESS ROAD AND PARKING;
N/A
PROPOSED COMPOUND AREA;
N/A
PROPOSED ACCESS ROAD AND PARKING;
CUT = 0 CU. YD.
FILL = 0 CU. YD.
PROPOSED TOWER FOUNDATION, (3) PIERS;
EXCAVATION = 82 CU. YD.
APPROX. TOTAL AREA OF DISTURBANCE OF PROPOSED GRADING = 500 SQ. FT.
REFER TO GEO-TECHNICAL ENGINEERING EVALUATION BY BLACK MOUNTAIN DATED 12/05/21
IMPERVIOUS AREAS
TOTAL PARCEL AREA = 5,575,244.4 SQ. FT.
PRE-DEVELOPMENT AREA; EXISTING IMPERVIOUS:
EXISTING COMPOUND = 8,584 SQ. FT.
EXISTING ACCESS & PARKING = 1,300 SQ. FT.
TOTAL = 9,884 SQ. FT.
POST-DEVELOPMENT AREA; NEW IMPERVIOUS:
NEW COMPOUND = 0 SQ. FT.
NEW ACCESS & PARKING = 0 SQ. FT.
TOTAL = 0 SQ. FT.
EXISTING GRADE
PROPOSED GRADE
TEMPORARY SILT FENCE
CONSTRUCTION ENTRANCE
FLOW DIRECTION
GROUND ELEVATION250
LEGEND
± 82 LF OF (P) SILT FENCE
SEE DETAIL ON ER-2
FLOW DIRECTION, TYP
(P) TOWER
(P) ICE-BRIDGE
GRADING &
EROSION CONTROL
DETAILS
ER-2
SHEET NUMBER:
SEDIMENT FENCE NOTES:
1. THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS WHERE FEASIBLE. THE FENCE POSTS SHALL BE SPACED A MAXIMUM OF 6'
APART AND DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24”.
2. THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM 6” OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST, OR OVERLAP 2” X 2” POSTS AND ATTACH AS SHOWN ON DETAIL SHEET 4-3A OF THE EROSION CONTROL MANUAL.
3. THE FILTER FABRIC SHALL HAVE A MINIMUM VERTICAL BURIAL OF 6”. ALL EXCAVATED MATERIAL FROM FILTER FABRIC INSTALLATION SHALL BE
BACKFILLED AND COMPACTED ALONG THE ENTIRE DISTURBED AREA.
4. STANDARD OR HEAVY-DUTY FILTER FABRIC FENCES SHALL HAVE MANUFACTURED STITCHED LOOPS FOR 2” X 2” POST INSTALLATION. STITCHED LOOPS
SHALL BE INSTALLED ON THE UP HILLSIDE OF THE SLOPED AREA.
5. FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN
PERMANENTLY PROTECTED AND STABILIZED.
6. FILTER FABRIC FENCES SHALL BE INSPECTED BY APPLICANT/CONTRACTOR IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING
PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
SETBACKS AND DRAINAGE DIMENSIONS
TEMPORARY SEDIMENT FENCE
PLASTIC SHEETING 3SCALE: NTS
2SCALE: NTS
4SCALE: NTS
GRAVEL CONSTRUCTION ENTRANCE 1SCALE: NTS
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
TOE OF
SLOPE
PL
PL
H/5 BUT 2' MINIMUM
AND NEED NOT EXCEED
20' MAXIMUM
TOE OF
SLOPE
H/5 BUT 2' MINIMUM AND
NEED NOT EXCEED 10'
MAXIMUM
NATURAL OR
FINISH GRADE
INTERCEPTOR DRAIN
(IF REQUIRED)
H
NATURAL OR
FINISH GRADE
CUT OR FILL
SLOPE
© 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS © 2022 TomTom
S 89° 17' 49" E
N
W
22X34 SCALE: 1" = 200' OVERALL SITE PLAN 1
OVERALL
SITE PLAN
C-1
SHEET NUMBER:
SHEET TITLE:
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
NOTE:
THIS IS NOT A SURVEY ALL
EXISTING INFORMATION IS
PROVIDED BY GIS.
PROPOSED PROJECT AREA
SEE SHEET C-2 FOR DETAILS
ACCOUNT: *10926516 / 10996427
11X17 SCALE: 1" = 400'
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10171085
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10171044
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10180301
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10180319
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10180503
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10497631
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10497623
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10497664
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10171077
ZONING
FR (COUNTY-FOREST RESOURCE)
ACCOUNT: 10467889
ZONING
FR (COUNTY-FOREST RESOURCE)
APPROX. LOCATION OF (E)
SUBJECT PROPERTY LINE
217.11'
4.1
9'CONTRACTOR TO EVALUATE
CONDITION OF (EX) ACCESS ROAD; SEE
C-5 FOR FOR TYPICAL ROAD SECTION
DETAIL IF REPAIR IS REQUIRED
(EX) EMERGENCY TURNAROUND
O
P
O
P
O
P
O
P
O
P
O
P
O
P
O/P
O/P
O/P
O/P
O/P
O/P
O/P
O/P
O/P
O
H
C
G
A
G
A
11X17 SCALE: 1" = 10' 22X34 SCALE: 1" = 5' ENLARGED SITE PLAN 1
ENLARGED
SITE PLAN
C-2
SHEET NUMBER:
SHEET TITLE:
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
E
X
S
L
O
P
E
(EX) TOWER
(EX) TOWER
(EX) FENCE, TYP
(EX) OTHER CARRIER
EQUIPMENT SHELTER
(EX) UTILITY POLE;
CO. B12019
PACIFICORP#
01337002
180500
POLE #23
(EX) TELCO PED.
(RPTR 10)
(EX) EQUIPMENT SHELTER
(EX) PROPANE TANK TO
BE REMOVED
(EX) TOWER TO BE
REMOVED. CONTRACTOR
TO COORDINATE WITH
ECSO PROJECT MANAGER
(EX) GENERATOR TO BE REMOVED
(EX) UTILITY POLE
1,2 C-3
(P) 120' SELF-SUPPORT
LATTICE TOWER. SEE
WESTERN UTILITY TOWER
DRAWINGS FOR STRUCTURAL.
(P) OTHER CARRIER CABLE
BRIDGE EXTENSION
(P) COAX ROUTE & CABLE BRIDGE
SEE C-4 FOR DETAIL
(EX) OVERHEAD
POWER LINE, TYP
E
X
A
C
C
E
S
S
G
A
T
E
(EX) VEGETATION LINE
(EX) UTILITY RACK
W
I
D
U
I
L
I
T
Y
E
A
S
E
M
E
N
T
(P) MICROWAVE
AZIMUTH = 332.92°
(EX) FAA LEASE AREA
(P) MICROWAVEAZIMUTH = 99.52°
(E) POWER TO BE
UTILIZED; SITE IS
CURRENTLY OPERATIONAL
(EX) 4' WIDE
ACCESS GATE
NOTES:
1. TOWER INFO SHOWN FOR CONCEPTUAL USE ONLY. SEE
TOWER STRUCTURAL DESIGN BY WESTERN UTILITY
DATED 11-04-22.
2. EXISTING INFORMATION PROVIDED BY GIS, SURVEY &
SITE WALK NOTES.
(EX) FENCE SECTION TO BE
REMOVED, TYP
S
E
T
B
A
C
K
(P) 500 GAL. PROPANE TANK
SEE SHEET C-6 FOR DETAIL
(P) GENERATOR ON 9'-6"x4'
CONCRETE PAD
SEE SHEET C-6 FOR DETAIL
(EX) 50'x50' LEASE AREA
(P) FENCE SECTION, TYP
PROVIDE AND INSTALL
AUTOMATIC TRANSFER SWITCH
MODEL ATS-G-1PH-11BE
(EX) GUY WIRE TO POWER
POLE TO BE RELOCATED
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
11X17 SCALE: 1" = 16' 22X34 SCALE: 1" = 8'EXISTING SOUTH ELEVATION 1 PROPOSED SOUTH ELEVATION 2
ELEVATIONS
C-3
SHEET NUMBER:
SHEET TITLE:
(EX) SHELTER, TYP
(EX) FENCE
GROUND LEVEL (GL)
(EX) PARABOLIC ANTENNA TO BE
RELOCATED, TYP
(ANTENNA CONFIGURATION
PENDING FINAL TOWER DESIGN)
(EX) SHELTER TOP ±10.0' AGL
(EX) ACCESS GATE
(EX) ±55' SELF-SUPPORT LATTICE
TOWER TO BE REMOVED AFTER
(P) TOWER IS CONSTRUCTED
(P) TOWER TOP ±120.0' AGL
(P) EQUIPMENT RACK TO BE
INSTALLED WITHIN (EX)
SHELTER, TYP OF (8)
(P) VHF RX ANTENNA
DB SPECTRA
DS1F06P36U-D
(P) ANTENNA TOP ±122.0' AGL
(EX) OMNI ANTENNA TO BE
REMOVED, TYP
(PENDING FINAL ANTENNA DESIGN)
11X17 SCALE: 1" = 16' 22X34 SCALE: 1" = 8'
(EX) UTILITY POLE
(EX) ANTENNA TO BE
REMOVED, TYP
(EX) PARABOLIC ANTENNA TO
BE REMOVED
(EX) VHF ANTENNA TO BE
REMOVED, TYP
(PENDING FINAL ANTENNA DESIGN)
(EX) TOWER EXTENSION TOP ±55.0' AGL
(EX) ANTENNA TOP ±70.0' AGL
(EX) ANTENNA TO BE
REMOVED, TYP
GROUND LEVEL (GL)
(EX) SHELTER TOP ±10.0' AGL
(EX) ANTENNA TOP ±30.0' AGL (EX) ANTENNA TOP ±30.0' AGL
(VERIFY)
(P) CABLE LADDER
(P) ANTENNA BASE ±60.0' AGL
(EX) PARABOLIC ANTENNA
RELOCATED TO (P) TOWER, TYP OF (2)
(VERIFY WITH FINAL RF DATA REPORT)
(P) ANTENNA BASE ±100.0' AGL
(P) MICROWAVE ANTENNA CL ±100.0' AGL
NOTES:
· SEE FINAL TOWER DESIGN
PRIOR TO REMOVAL AND/OR
RELOCATION OF EXISTING
ANTENNAS
· TOWER REMOVAL BY OTHERS
(EX) SHELTER, TYP
(EX) FENCE
(EX) 4' WIDE ACCESS GATE;
INSTALL (P) SIGNAGE
(EX) UTILITY POLE
(P) CABLE ROUTE ATTACHED TO (EX)
TOWER PER FINAL STRUCTURAL
TOWER AND/OR MOUNT ANALYSIS
(P) 4'Ø MICROWAVE ANTENNA;
COMMSCOPE – VHLP4-11
AZIMUTH = 332.92°
(TO GOLD HILL)
(P) 2 BAY DIPOLE VHF ANTENNA
(W/ 4 DIPOLES);
BA40-41-P
AZIMUTH: 0°
(P) 120' SELF-SUPPORT LATTICE
TOWER; CAPACITY OF TOWER & ITS
FOUNDATION TO SUPPORT PROPOSED
LOADING TO BE PROVIDED BY OTHERS
(P) MOUNT
SITE PRO 1
MODEL# BOG6
(P) MOUNT
SITE PRO 1
MODEL# PSA6
(P) 4'Ø MICROWAVE ANTENNA;
COMMSCOPE – VHLP4-11
AZIMUTH = 332.92°
(TO GOLD HILL)
(P) MICROWAVE SHIELD
NEWAVE
MIS4
(P) MICROWAVE MOUNT, TYP OF (2)
SITE PRO 1
TAM-3U OR APPROVED EQUAL
NOTES:
1. TOWER INFO SHOWN FOR CONCEPTUAL USE ONLY.
SEE TOWER STRUCTURAL DESIGN BY WESTERN UTILITY.
2. REFER TO TOWER AND FOUNDATION STRUCTURAL
DRAWINGS BY WESTERN UTILITY DATED 11-04-22.
3. REFER TO RF TOWER APPURTENANCES SHEETS
FOR MORE INFORMATION.
NOTES:
· CONCEPTUAL USE ONLY
· EXISTING TREES NOT SHOWN
FOR CLARITY
· PROPOSED ANTS. TO BE LIGHT
GRAY OR LIGHT BLUE IN COLOR
· TOWER TO BE PAINTED A DULL,
NON-REFLECTIVE GRAY COLOR
(P) MICROWAVE ANTENNA CL ±70.0' AGL
(P) MICROWAVE SHIELD
NEWAVE
MIS4
(EX) PROPANE TANK TO BE
REPLACED WITH A NEW 500
GALLON PROPANE TANK
(EX) GENERATOR TO BE
REPLACED WITH A NEW
GENERATOR
(P) ANTENNA BASE ±80.0' AGL
(P) 700 MHZ ANTENNA
BPA7496-120-15
TYP OF (2)
(P) MOUNT
SITE PRO 1
MODEL# PSA3
TYP OF (2)
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21 SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
COMPOUND
DETAILS I
C-4
SHEET NUMBER:
SHEET TITLE:
FENCING NOTES:
1. GATE POST, CORNER, END, OR PULL POST 4" NOMNIAL (4" O.D.) SCHEDULE 40 (50
KSI) PIPE, FOR GATE WIDTHS UP TO 6 FEET OR 12 FEET FOR DOUBLE SWING GATE
PER ASTM-F1083.
2. LINE POST: 2-3/8" O.D. 3.65 LBS/LIN FT. ASTM-F1083.
3. TOP RAIL AND BRACE RAIL: 1-1/2" (1.9" O.D.) PIPE 2.72 LBS/LIN FT PER ASTM-F1083.
INSTALL BRACE AT ALL CORNER LOCATIONS AND ADJACENT TO GATES.
4. GATE FRAME: 1-1/2" (1.9 O.D.) 2.72 LBS/LIN FT. ASTM-F1083.
5. FABRIC SHALL BE TWO-INCH CHAINLINK MESH NO. 9 GAUGE (0.148") WIRE. THE
FABRIC SHALL HAVE A KNUCKLED FINISH FOR THE TOP SELVAGES. FABRIC SHALL
CONFORM TO ASTM A-392 CLASS 1.
6. TIE WIRE: MINIMUM 11Ga. GALVANIZED STEEL. PROVIDE A SINGLE WRAP OF
FABRIC, TIE AT POSTS, RAILS, AND AT TENSION WIRE BY HOG RINGS. MAXIMUM
SPACING 24" O.C.
7. TENSION WIRE: MINIMUM 7 Ga. GALVANIZED STEEL.
8. U.N.O. BARBED WIRE: DOUBLE STRAND 12 Ga. 1/2" O.D. TWISTED WIRE TO MATCH
W/ FABRIC, 14 Ga. 4PT. BARBS SPACED ON APPROX. 5" CENTERS.
9. U.N.O. BARBED WIRE GATE GUARDS SHALL BE FITTED WITH DOME CAPS.
10. U.N.O. BARBED WIRE SUPPORT ARMS SHALL BE PRESSED STEEL COMPLETE WITH
SET BOLT AND LOCK WIRE IN THE ARM.
11. PROVIDE TWO 6 FOOT WIDE OUT SWINGING GATES, (UNLESS NOTED OTHERWISE).
NO PERSONNEL GATES ARE REQUIRED (UNLESS AS DIRECTED BY THE PROPERTY
OWNER). GATES SHALL BE ABLE TO LOCK.
12. U.N.O. GATE POSTS SHALL BE EXTENDED 12 INCHES, INCLUDING DOME CAP, TO
PROVIDE FOR ATTACHMENT OF BARBED WIRE.
13. GATE FRAMES SHALL HAVE A FULL-HEIGHT VERTICAL BRACE, AND A FULL-WIDTH
HORIZONTAL BRACE, SECURED IN PLACE BY USE OF GATE BRACE CLAMPS.
14. GATE HINGES SHALL BE MERCHANTS METAL MODEL 64386 HINGE ADAPTOR WITH
MODEL 6409, 180-DEGREE ATTACHMENT OR APPROVED EQUAL.
15. GATE LATCH: 1-3/8" O.D. PLUNGER ROD W/ MUSHROOM TYPE CATCH.
16. A 6" X 1/2" DIAMETER EYEBOLT TO HOLD TENSION WIRE SHALL BE PLACED AT LINE
POSTS.
17. STRETCHER BARS SHALL BE 3/16" OR HAVE EQUIVALENT CROSS-SECTIONAL AREA.
18. U.N.O. ALL POSTS EXCEPT GATE POSTS SHALL HAVE A COMBINATION CAP AND
BARBED WIRE SUPPORTING ARM.
19. ALL CAPS SHALL BE MALLEABLE IRON, DOME OR ACORN SHAPED AS REQUIRED BY
PIPE SIZE.
20. OTHER HARDWARE MAY INCLUDE BUT NOT BE LIMITED TO TIE CLIPS, BAND CLIPS
AND TENSION BAND CLIPS.
21. U.N.O. WHERE THE USE OF CONCERTINA HAS BEEN SPECIFIED, 24" DIAMETER COIL.
BARBED TAPE, STAINLESS STEEL, CYCLONE FENCE MODEL G8P TO TYPE lll SHALL BE
FURNISHED. IT SHALL BE SUPPORTED ABOVE THE TOP RAIL BY USE OF SIX (6)
BARBED WIRE ARMS POSITIONED ATOP EACH LINE/CORNER POST.
22. U.N.O. ALL CHAINLINK FENCING COMPONENTS MUST BE HOT DIPPED GALVANIZED.
23. WHEN IN USE, PRIVACY SLATS TO BE A NEUTRAL COLOR.
SCALE: NTS
1SCALE: NTS
NOT USED 2SCALE: NTS
GENERAL FENCE NOTES 4SCALE: NTS
5SCALE: NTS
ICE BRIDGE DETAIL 6SCALE: NTS
SIGN DETAILSNOT USED
NOT USED 3
SIGN NOTES:
1. SIGN MATERIAL: 18GA
ALUMINUM
2. LETTERING COLOR =
BLACK / WHITE
3. BACKGROUND COLOR =
WHITE / BLUE
7"
SIGN NOTES:
1. SIGN MATERIAL: 18GA
ALUMINUM
2. LETTERING COLOR =
BLACK
3. BACKGROUND COLOR =
WHITE / RED
12"
SIGN NOTES:
1. SIGN MATERIAL: 18GA
ALUMINUM
2. LETTERING COLOR =
BLACK
3. BACKGROUND COLOR =
YELLOW
36" OC MAX
10'-0" OC MAX
FIELD VERIFY12"
2"CLR.
2'-0"
CLR MIN.
COAX BRIDGE: 14 GA.
GALV. GRIPSTRUT 24"
WIDTH, 2" PLANK 14 GA.
SUPPORT COLUMN: 4"Ø
O.D. GALV. SCHED. 40
POST @ 10'-0" O.C. MAX
CROWN TO DRAIN; TYP.
FOOTING
MUST BE 6"
BELOW
FROST LINE,
TYP.
SIDE ELEVATIONFRONT ELEVATION
NOTE: GROUND COAX BRIDGE PER THE REQUIREMENTS
OF THE NEC STANDARDS - SEE DETAIL 1/E-2
COAX SUPPORT BLOCKS
AT 3'-0" MAX O.C.
EDGE OF
SHELTER
20" UNISTRUT W/ NUT
AND WASHER EACH
SIDE/ EACH LEVEL AS
REQUIRED
12"Ø X 48" DEEP CONC.
FOOTING; TYPICAL
COAX BRIDGE-(2) 24" WIDE
SAFETY GRATED WAVE
GUIDE BRIDGE CHANNEL,
OR APPROVED EQUAL
DUAL POST 24" ICE
BRIDGE KIT SITE PRO1
PART# 4B24D OR
APPROVED EQUAL
8"
2-1/2"
1-1/2"
8" x 8" x 1/2" PLATE
SUPPORT PIPE
1/2"Ø HILTI-KWIK-BOLT-TZ
SS EXPANSION ANCHOR
MIN 2" EMBED (TYP. OF 4)
5/16 TYP
8" x 8" x 1/2" PLATE
CONC. SLAB (IF
REQUIRED)
B
ICE-BRIDGE
SUPPORT POST
SECTION B
BASE PLATE - OPTIONAL
PIPE TO CONC
ATTACHMENT
7"
ECSO 911
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21 SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23 BID DRAWINGS
04-26-23
UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23 REV. FINAL CONSTRUCTION DRAWINGS
11-14-23
REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
COMPOUND
DETAILS II
C-5
SHEET NUMBER:
SHEET TITLE:
4" OF 3/4" CHIP ROCK;
NO FINES
GEOTEXTILE FABRIC,
TYPAR-3401
OR EQUIVALENT
4" OF 3/4"-MINUS
CRUSHED ROCK
COMPACTED 95%
SUBSOIL COMPACTED TO 92% OF
MAXIMUM DRY DENSITY MIN. PER
ASTM-D1557
NOTE: STRIP ALL ORGANICS
3" MIN OF 3/4" MINUS CRUSHED
ROCK COMPACTED TP 95% IN
ACCORDANCE WITH ASTM-D698
GEOTEXTILE FABRIC,
MIRAFI 500X (12"
OVERLAP AT SEAMS)SUBSOIL COMPACTED TO 92% OF
MAXIMUM DRY DENSITY MIN PER
ASTM-D1557
NOTES:
1. CONTRACTOR SHALL STRIP SUPERFICIAL, SOFT, WET, ORGANIC OR DELETERIOUS SOILS TO EXPOSE FIRM AND UNYIELDING SOIL (BETWEEN 6" & 12"). IF STRIPPING IS REQUIRED DEEPER THAN 12", CONTRACTOR SHALL CONTACT THE SITE CONSTRUCTION MANGER TO DETERMINE THE APPROPRIATE STRIPPING DEPTH AT THE TIME
OF CONSTRUCTION.
2. MATERIAL AND INSTALLATION SHALL CONFORM TO CURRENT ODOT/APWA STANDARD SPECIFICATIONS AND
MANUFACTURERS RECOMMENDATIONS.
12" MIN OF 3" MINUS
CRUSHED ROCK COMPACTED
TO 95% IN ACCORDANCE WITH
ASTM-D698
POWER LINE TRENCH
4SCALE: NTS NOT USED ACCESS ROAD SECTION DETAIL 5SCALE: NTS
3SCALE: NTS2 COMPOUND ROCK SECTION DETAILSCALE: NTS1SCALE: NTS GRAVEL ROAD SECTION DETAIL
SLIM18/PC
MANUFACTURER
RAB LIGHTING
DIMENSIONS
6.5"X8.75"X3.9"
MODEL NUMBER WEIGHT
4.5 lbs
EXTERIOR SHELTER LIGHT
PROVIDED WITH STATE
APPROVED SHELTER
6LED SHELTER LIGHT
" E
LE
CT
RI
CA
L P
RI
MA
RY
" E
LE
CT
RI
CA
L S
EC
ON
DA
RY
2'- 6"
T O
3'- 6"
4" 4"
12" MIN
CLEAR
24"±
WARNING TAPE
FINISH GRADE
UNEXCAVATED EARTH
COMPACTED FILL
(85% IN LANDSCAPED AREAS,
95% IN PAVED AREAS)
ELECTRICAL CONDUIT(S); 3"Ø
MIN, SCHEDULE 40 PVC, OR
AS SHOWN ON PLAN
COMPACTED SANDNOTES:
1. EXCAVATE TO REQUIRED DEPTH.
2. VERIFY ALL TRENCHING REQUIREMENTS PER LOCAL UTILITIES.
3. CONTRACTOR TO PROVIDE (1) 300 POUND NYLON PULL CORD
AND CONDUCTORS AS REQUIRED PER CONDUIT.
CONTRACTOR TO VERIFY
WITH ECSO PM IF SPARE
CONDUIT TO BE PLACED IN
TRENCH FOR FUTURE
7 NOT USEDSCALE: NTS SCALE: NTS
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21 SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23 BID DRAWINGS
04-26-23
UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23 REV. FINAL CONSTRUCTION DRAWINGS
11-14-23
REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
GENERATOR &
PROPANE TANK
DETAILS
C-6
SHEET NUMBER:
SHEET TITLE:
35 KW 60 HZ 44KVA AC
BACKUP GENERATOR
MANUFACTURER TBD
GENERATOR TO BE
PROVIDED BY ECSO
G A
S G
A S
G A
S G
A S
10'-0" REQUIRED PROPANE
TANK SETBACK BUFFER;
NO IGNITION SOURCES
WITHIN SETBACK
NOTE:
ALL CONDUIT INSIDE THE BUILDING MUST BE METAL AND BE GROUNDED PER R-56 STANDARDS.
INTERIOR SHELTER LAYOUT IS FOR REFERENCE ONLY.
THIS GENERATOR & PROPANE LAYOUT IS FOR INFORMATION ONLY AND IS PRESENTED AS A GUIDELINE. VERIFY SITE CONDITIONS AND LAYOUT PRIOR TO INSTALLATION OF ALL EQUIPMENT. INSTALL ALL EQUIPMENT PER MANUFACTURER'S
INSTRUCTIONS.
FUEL LINE SIZE PER MANUFACTURERS
RECOMMENDATION
1-CAT-5 FOR HALL EFFECT FUEL
SENSOR WIRE SUPPLIED BY
OTHERS IN 3/4" RIGID PVC
CONDUIT FROM GENERATOR TO
PROPANE TANK
3-#2 THHN PLUS #8
GROUND IN 2" RIGID
PVC CONDUIT FROM
GENERATOR TO
TRANSFER SWITCH
EQUIPMENT SHELTER
10'
TRINITY LIQUID PROPANE
FUEL TANK OR EQUAL ON
CONCRETE PAD
2-CAT-5 CONTROL WIRING IN 3/4"
RIGID PVC CONDUIT
AUTOMATIC TRANSFER SWITCH
CIRCUIT BREAKER PANEL
POWER CONDUIT TO STUB UP AT
METER
BORE AND WEATHERPROOF NEW PENETRATIONS
INTO SHELTER FOR NEW CONDUIT ROUTING, TYP.
LIQUID WITHDRAWL
DOME
RELIEF VALVE
2-#12 THHN PLUS #12 GROUND IN
1" RIGID METAL CONDUIT FROM
GENERATOR TO DEDICATED
CIRCUIT BREAKER @ BREAKER
PANEL, RATING 20A
MANUAL TRANSFER SWITCH
35 KW 60 HZ 44KVA AC
BACKUP GENERATOR
MANUFACTURER TBD
GENERATOR TO BE
PROVIDED BY ECSO
GENERATOR SEE DETAIL 5
SHUT-OFF VALVE
LEGEND
UNION
PRESSURE REGULATOR
SOLENOID VALVE
FLEXIBLE CONNECTION
3/4" DIA. CONDUIT W/ 1-4/18 AWG
1/4" FLEX FUEL LINE FROM PROP
TANK TO REG
SOLENOID VALVE AND
REGULATOR TO COME
WITH GENSET
TO CARBURETOR
NOTES:
1. GROUND SYSTEM SHOULD COMPLY WITH INDUSTRY STANDARDS
2. CONFIRM CONNECTIONS PROVIDED WITH FUEL TANK
3. USE GASEOUS LP VAPOR WITHDRAWAL SYSTEM
4. TO CODE OFFICIAL, PAD IS FOR EQUIPMENT ONLY (NO BUILDINGS)
5. CONTRACTOR IS TO VERIFY THAT ALL PROPOSED ANCHORS WILL PROVIDE ADEQUATE FIT
PRIOR TO POURING CONCRETE PADS, NOTIFY DON CUSHING ASSOCIATES IF ANY
DISCREPANCIES EXIST
C-9
NOTES:
1. PROPANE TANK REGISTERED WITH
NATIONAL BOARD AND COMPLIES
AND INSTALLED PER NFPA 58 CODE
2. PROPANE TANK INSTALLED AT LEAST
10 FT FROM EXTERNAL SOURCE OF
IGNITION
TRINITY LIQUID
PROPANE FUEL
TANK OR EQUAL
SEE PROPANE TANK SPEC SHEET
FOR DIMENSIONS AND WEIGHTS
# 4 X 25"X12" @
12" O.C. TYP.
8" 4"
12"
1ST STAGE REG; LV4403TR96 14" IN
AND 3/4 " OUT
2ND STAGE REG LV5503B8;
4" IN AND 1" OUT
SNAP2IT NON-METALLIC CONN 34"
NM LIQUID TIGHT CONN CAT 5
GALV. 1 12" Ø STAND PIPE POST
(1.9" OD) W/ CAP
SHUT-OFF VALVE W/ DRIP LEG
HOR. UNI-STR W/ NON
CORR PIPE CLAMP
SERVI-SERT TOP-CON RISER
5'-0" X 16'-0" X 8" CONCRETE
PAD W/ #4 @ 12" O.C. EA WAY
GROUND PROPANE TANK
PER NEC REQUIREMENTS
DOME
PLUG
RELIEF VALVE
VAPOR WITHDRAWAL
# 4 CONT. IN
TURNED-DOWN EDGE
FOOTING
FINISHED GRADE
6" MIN. COMPACTED GRAVEL
BASE UNDER PERIMETER
FOOTING AND SLAB
FUEL GAUGE, R3D
3/4" ULTRATITE LIQUIDTIGHT FLEX
NON-MET PVC COND FOR 1-4/18 AWG
FOR HALL EFFECT FUEL SENSOR,
DS_1318
CUSTOM PROPANE TANK
CANOPY GENERATOR CANOPY NOT
SHOWN FOR CLARITY
UFER GROUND
5/8" X 5" SS TITEN HD
ANCHORAGE, TYP
18"
6" MIN. COMPACTED GRAVEL
BASE UNDER PERIMETER
FOOTING AND SLAB
12"
# 4 CONT. IN
TURNED-DOWN EDGE
FOOTING
UFER GROUND
4'-0" X 9'-6" X 8"
CONCRETE PAD W/ #4
@ 12" O.C. EA WAY
SCALE: NTS 1
SCALE: NTS
SCALE: NTS
SCALE: NTSSCALE: NTS
2-CAT-5 CONTROL WIRING
IN 3/4" RIGID PVC
CONDUIT
3-#2 THHN PLUS #8
GROUND IN 2" RIGID PVC
CONDUIT
1-CAT-5 HALL EFFECT
FUEL SENSOR WIRING IN
3/4" RIGID PVC CONDUIT
GENERATOR PLAN
GENERATOR FUEL SYSTEM ELEVATION
2-#12 THHN PLUS #12
GROUND IN 3/4" RIGID PVC
CONDUIT (BLOCK HEATER
AND BATTERY CHARGER)
FUEL LINE CONNECTION PER
MANUFACTURER RECOMMENDATION
FRONT
SIDE
FRONT
SIDE
35 KW 60 HZ 44KVA AC
BACKUP GENERATOR
MANUFACTURER TBD
GENERATOR TO BE
PROVIDED BY ECSO
TRENCH SECTION NOT USED
2SCALE: NTS GENERATOR ELEVATION NOT USED
TYPICAL GENERATOR LAYOUT
NOTE: DOCUMENTATION FOR THE GENERATOR IS TO BE PROVIDED BY THE SUPPLIER CERTIFYING THAT ALL HAZARDOUS CONTENTS WILL REMAIN CONTAINED FOLLOWING THE DESIGN EARTHQUAKE FOR THIS SITE. CERTIFICATION OF CONTAINMENT IS TO BE PROVIDED BY 1) ANALYSIS, 2) APPROVED SHAKE TABLE TESTING IN ACCORDANCE WITH SECTION 13.2.5 OF ASCE 7, OR 3) EXPERIENCE DATA IN ACCORDANCE WITH ASCE 7 SECTION 13.2.6. EVIDENCE DEMONSTRATING COMPLIANCE OF THIS REQUIREMENT SHALL BE SUBMITTED TO THE LOCAL JURISDICTION AFTER REVIEW AND APPROVAL BY THE ENGINEER OF RECORD.
SEE GENERATOR SPEC SHEET FOR DIMENSIONS
AND WEIGHTS
(4) 1/2"Ø X 5" EMBED.
TITEN HD ANCHORS,
SEE DETAIL #3 THIS
SHEET
(4) 3/4"Ø X 5" EMBED.
TITEN HD SS
ANCHORS
35 KW 60 HZ 44KVA AC
BACKUP GENERATOR
MANUFACTURER TBD
GENERATOR TO BE
PROVIDED BY ECSO
FUEL LINE CONNECTION
PER MANUFACTURER
RECOMMENDATION
SCALE: NTS 4 GENERAL NOTES
SCALE: NTS 6
1. CONTRACTOR TO VERIFY AND CONFIRM ALL DIMENSIONS
AND CONDITIONS AND NOTIFY ENGINEER OF RECORD OF
ANY DISCREPANCIES PRIOR TO START OF WORK.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
STRUCTURAL STABILITY DURING CONSTRUCTION. THE
STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN
DESIGNED FOR STABILITY UNDER THE FINAL
CONFIGURATION ONLY.
3. CODE: 2019 OREGON STRUCTURAL SPECIALTY CODE
(OSSC).
4. THE FOOTINGS HAVE BEEN DESIGNED FOR AN ALLOWABLE
SOIL BEARING PRESSURE OF 1,500 PSF.
5. CONCRETE: FOOTINGS, F'C = 3,000 PSI MINIMUM
COMPRESSIVE STRENGTH AT 28 DAYS.
6. REINFORCING STEEL: FY = 60,000 PSI
7. STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE IN
ACCORDANCE WITH AISC SPECIFICATION FOR THE DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDINGS AND SHALL BE ASTM A-36 U.O.N. ALL BOLTS
HOLES SHALL BE PUNCHED OR DRILLED; BURNING OF
HOLES SHALL NOT BE PERMITTED. ALL STRUCTURAL STEEL
SHALL HAVE ONE SHOP COAT OF PAINT.
ALL MATERIALS SHALL CONFORM TO THE FOLLOWING
STANDARDS:
PIPE: A53 GR. B (MIN. FY = 35 KSI)
SHAPES: ASTM A36/ ASTM A572 GR. 50
WIDE FLANGE: ASTM A992
TUBES: A500 GR. B, FY = 46 KSI
PLATES: A36
WELDS: E70XX ELECTRODES
STRUCTURAL BOLTS: ASTM A325N
NON-STRUCTURAL BOLTS: SAE J429 GR. 5 / F1554-36
U-BOLTS: ASTM A36
THREADED ROD: ASTM A307
SPECIAL INSPECTION BY OWNERS TESTING AGENCY
SPECIAL INSPECTIONS AND TESTING SHALL BE PERFORMED BY
AN APPROVED AGENCY IN ACCORDANCE WITH OREGON
STRUCTURAL SPECIALTY CODE (OSSC) SECTIONS 1703 AND 1704,
AND WITH THE STATEMENT OF SPECIAL INSPECTIONS AS
REQUIRED BY OSSC SECTIONS 1704.1.1 AND 1705 FOR BUILDING
STRUCTURAL ELEMENTS SUMMARIZED AS FOLLOWS;
1. STRUCTURAL STEEL CONSTRUCTION PER OSSC SECTIONS
1704.3 AND TABLE 1704.3 INCLUDING MATERIAL
IDENTIFICATION, AND SHOP WELDING.
1'-4"
1'
SCALE: NTS 7
4"
NONVEHICULAR AREAS:
BACKFILL WITH CLEAN NATIVE
BACKFILL AND COMPACT TO
90% MAX. DRY DENSITY.
VEHICULAR AREAS: BACKFILL
WITH GRANULAR 'A' AND
COMPACT TO 95% MDD
2'
WARNING TAPE
CONDUIT, TYPICAL
BRICK SAND
FUEL LINE SIZE AND TRACE
WIRE PER MANUFACTURERS
RECOMMENDATION
NOT USED
CONCRETE PAD
SEE DETAIL 5
BACKUP GENERATOR
MANUFACTURER TBD
6.7'
14.7'
8.0'
G A
GATE 4'
LICENSURE:
DRAWING INFORMATION:
THIS DRAWING IS COPYRIGHTED AND IS THE SOLE
PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY
FOR USE BY THE OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING AND/OR
THE INFORMATION CONTAINED IN IT IS FORBIDDEN
WITHOUT THE WRITTEN PERMISSION OF THE OWNER.
PLANS PREPARED BY:
DATE RELEASE
09-22-21
SITE SKETCH
11-10-21 PRELIM ZONING DRAWINGS
10-31-22 FINAL ZONING DRAWINGS
04-13-23
BID DRAWINGS
04-26-23 UPDATED BID DRAWINGS
05-11-23 FINAL CONSTRUCTION DRAWINGS
07-31-23
REV. FINAL CONSTRUCTION DRAWINGS
11-14-23 REV. FINAL CONSTRUCTION DRAWINGS
PROJECT INFORMATION:
ECSO 9-1-1
JOHN'S PEAK
2563 JOHNS PEAK RD
CENTRAL POINT, OR 97502
12725 SW MILLIKAN WAY, SUITE 300
BEAVERTON, OR 97005
(503) 387-5331 www.cushingcivilengineers.com
Cushing
Civil Engineers
Civil Engineers
SITE GROUNDING
PLAN & DETAILS
E-1
SHEET NUMBER:
SHEET TITLE:
11X17 SCALE: 1" = 8' 22X34 SCALE: 1" = 4' SITE COMPOUND GROUNDING PLAN 1
SCALE: NTS 3 SCALE: NTS 2 TERRADYNE ELECTROLYTIC GROUND ELECTRODE
GENERAL NOTES:
1. ALL INSTALLATIONS ARE TO BE FIELD VERIFIED.
2. GROUND CONDUCTORS ARE TO BE BURIED AT A MINIMUM 30" BELOW
GRADE OR 6" BELOW…
This is the start of the file's text. The full file is on GovTribe.