The document is a set of technical drawings for a Base Pavements Indefinite Delivery/Indefinite Quantity (IDIQ) Basic Contract for Grand Forks Air Force Base (Project Number JFSD240005). The drawings provide detailed specifications for various pavement and infrastructure improvements, including:
Pavement sections with multiple configurations (concrete and asphalt), including typical sections for 5" and 6" pavements with details on aggregate base, subgrade, and surface courses. The drawings include technical specifications for curb and gutter installations, roadway and sidewalk details, trench backfill, manhole and inlet designs, handrail dimensions, and street light pole foundations. Additional technical details cover joint types, aggregate specifications, and installation requirements for various infrastructure elements. The drawings are comprehensive engineering plans intended to guide construction and renovation of base infrastructure, with a focus on precise dimensional and material specifications for pavement and related civil engineering components.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE PAVEMENTS IDIQ BASIC CONTRACT
BA
SE
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
CIVIL
GENERAL
C C C C C E
PR
OJ
EC
T
NU
MB
ER
JF
SD
JFSD240005
SE
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
C
PR
OJ
EC
T
NU
MB
ER
JF
SD
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
C
PR
OJ
EC
T
NU
MB
ER
JF
SD
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
C
PR
OJ
EC
T
NU
MB
ER
JF
SD
BA
SE
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
C
PR
OJ
EC
T
NU
MB
ER
JF
SD
Typical Handrail Cross Section
SE
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
C
TYPICAL HANDRAIL DIMENSIONS
PR
OJ
EC
T
NU
MB
ER
JF
SD
P
AV
EM
EN
TS
B
AS
IC
C
ON
TR
AC
T
DE
TA
ILS
E
SCREW IN BASE DETAIL
SCALE: NTS
1. SEE SITE PLAN FOR LOCATIONS AND
QUANTITY.
2. CUT CONDUIT FLUSH WITH TOP SURFACE OF
CONCRETE BASE.
3. PROVIDE 6’-0” OF COILED WIRE AT TOP OF
EACH BASE.
4. PROVIDE SPARE 1-1/2” PVC FROM EACH
LIGHT BASE.
5. SEE LUMINAIRES, GROUNDING AND
BONDING SPECIFICATION SECTIONS.
6. PROVIDE VIBRATION DAMPENERS FOR ALL
POLES/POSTS.
7. ALL POLE/POSTS SHALL HAVE HANDHOLES
NEAR BASE
8. EITHER BASE DETAIL SHALL BE ACCEPTABLE.
LIGHT POLE BASE DETAIL NOTES: ELECTRICAL SHEET NOTES:
INSTALL EXISTING FIXTURE HEAD ON NEW POLE.
PROVIDE NEW WIRE TO EXISTING FIXTURE WITH
TIE IN AT BASE.
PROVIDE HAND HOLD TO TIE NEW CIRCUIT INTO
EXISTING CIRCUIT.
RECONNECT EXISTING CIRCUIT AT NEW POLE BASE.
PR
OJ
EC
T
NU
MB
ER
JF
SD
| JFSD201705 - G001 Title Sheet |
| JFSD201705 - G002 Site Plan |
| JFSD201705 - A110 Demo |
| JFSD201705 - A111 Area Plan |
| JFSD201705 - A112 - Reflected Cieling Plan |
| JFSD201705 - A400 - Enlarged Plans |
| JFSD201705 - A401 Interior Elevations |
| JFSD201705 - A402 Details |
File details come from the government source that posted it. Updated .