This document is a Sole Source (Including Brand Name) Justification for Simplified Procedures for Certain Commercial Items, prepared by the 6th Contracting Squadron at MacDill Air Force Base. The document seeks to procure bi-annual maintenance for two C30 Capstone Micro Turbines and related components located inside the High-Altitude Electromagnetic Pulse (HEMP) Shelter. The maintenance will be performed twice annually by E-Finity Distributed Generation, the sole authorized distributor for Capstone Turbine equipment in the Mid-Atlantic and Southeastern United States.
The maintenance scope includes comprehensive system checks such as general cleaning, fuel system component inspection, leak checks, software verification and updates, electrical component assessments, and air filter inspections. E-Finity will provide one replacement engine and electronic filter annually, along with full service reports detailing work completed and system status. The contract justifies the sole source selection based on E-Finity being the only authorized service provider with factory-authorized components, and market research confirming no alternative vendors in the region can fulfill the specific maintenance requirements for these specialized micro turbines.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Statement of Work.pdf | ||
| Notice of Intent.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sole Source (Including Brand Name) Justification - Simplified Procedures for Certain Commercial Items
CONTROLLED UNCLASSIFIED INFORMATION
March 2023 CONTROLLED UNCLASSIFIED INFORMATION Page 2 of 3
This action is being processed as a Sole Source. The 6th Communication Squadron is seeking to procure a bi-annual maintenance for two (2) C30 Capstone Micro Turbines and its related components inside the High- Altitude Electromagnetic Pulse (HEMP) Shelter, located northeast of building #570 MacDill AFB 7115 South Boundary Blvd. Tampa, FL 33621. Bi annual maintenance will be performed twice per annual contract period.
These site visits provide Dual Mode Operation testing, verifying proper operation and function of the turbine generator.
General overall cleaning and inspection of the installation is to be completed during each site visit. Inspection of the fuel system components and leak check on all fittings to be performed. System software to be verified, and updated if necessary, per manufacturer's recommendation. Electrical components to be checked for corrosion and proper voltages, including battery system and power electronics modules. Inspect and clean as necessary the engine air and electronic air filters, E-Finity to provide up to one (1) replacement engine and electronic filter annually, as necessary per manufactures recommendation. Provide full service report after site visit detailing work completed, system status, and any recommended maintenance. Provide necessary costs for travel and per diem for each site visit included in this scope of work. Any emergency or unscheduled site visits will incur necessary travel and per diem costs accordingly.
Sole Source (Including Brand Name) Justification - Simplified Procedures for Certain Commercial Items
CONTROLLED UNCLASSIFIED INFORMATION
March 2023 CONTROLLED UNCLASSIFIED INFORMATION Page 3 of 3