This document is a Reflected Ceiling Plan (RCP) for Level 1 of Building 1 for the Lewis County Site Development project, prepared by KMB Architects for the Lewis County Facilities Department located in Chehalis, Washington. The architectural drawing provides detailed specifications for ceiling types, heights, and installations, including various ceiling materials such as acoustical panels (ACT-1 and ACT-2), wood soffits (WD-1), gypsum board (GWB), and areas marked as open to structure (OTS). The plan includes multiple ceiling height notations ranging from 8' to 9' 4", with typical ceiling height set at 9' 0", and indicates locations for mechanical grilles, lighting fixtures, exit signs, and ceiling access panels.
The drawing includes comprehensive general notes specifying ceiling installation requirements, such as painting exposed structures, aligning soffits with adjacent walls, coordinating ceiling access doors with mechanical and electrical contractors, and providing additional support for ceiling-mounted items. The plan uses a 1/8" = 1'-0" scale for the main reflected ceiling plan and a 1/4" = 1'-0" scale for the vestibule area. The document is part of a bid set dated 03-10-2023, prepared for the Lewis County Facilities Department's site development project, with the architectural sheet number A-152 and the project number J2037C.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6 107 8 9
A
B
C
D
E
8' - 0"
9' - 0"
9' - 4"
8' - 0"
9' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
9' - 0"
9' - 0"
9' - 0"
8' - 0"
8' - 0"
8' - 0"
R E
F E
R T
O A
-1
R E
F E
R T
O A
-1
DS
DS
DS DS
DS
DS
DSDSDSDS
A-152
OTS
10'-10"
10'-10"
8'-6"
9'-10"
9'-10"
9'-10"
9'-10"
OTS
9' - 0"
8' - 5"
9' - 10 1/4"
9' - 0"
9' - 6"
9' - 6"
9' - 6"
9' - 0"
OTS
9' - 0"
CEILING TYPES: XX TYPE
X' - X" HEIGHT
OPEN TO STRUCTURE- R-49 RIGID INSULATION APPLIED TO
UNDERSIDE OF ROOF DECK PAINTED BLACK
ACT-1 -2x4 SUSPENDED ACOUSTICAL CEILING PANEL AND
CONCEALED GRID SYSTEM
WD-1- 3/4" T & G WOOD SOFFIT OVER 1/2" PLYWOOD SHEATHING
ACT-2 -2x2 SUSPENDED ACOUSTICAL CEILING PANEL AND
CONCEALED GRID SYSTEM- BASIS OF DESIGN ARMSTRONG
WORDWORKS VECTOR
GWB OVER STEEL STUD FRAMING
MOLD/ MOISTURE RESISTANT GYPSUM BOARD OVER STEEL
STUD FRAMING
FULL HEIGHT WALL UP TO BOTTOM OF METAL DECKING AT ROOF ABOVE.
LOCATION OF EXTERIOR WALL ABOVE, BETWEEN LOWER AND UPPER ROOFS.
1. THESE GENERAL NOTES APPLY TO ALL REFLECTED CEILING PLANS.
2. CEILING HEIGHTS ARE FROM FINISH FLOOR UNO.
3. TYPICAL CEILING HEIGHT TO BE 9' - 0", UNO.
4. ALIGN SOFFITS WITH FACE OF ADJACENT WALL, UNO
5. NOT ALL LIGHTING, INCLUDING PENDANT AND WALL MOUNTED LIGHT FIXTURES,
SHOWN. SEE ELECTRICAL.
6. OTS = OPEN TO STRUCTURE. PAINT ALL EXPOSED CEILING/ROOF STRUCTURE, UNO.
7. U.N.O. - PAINT ALL GWB CEILINGS & SOFFITS PT-1 ( SEE FINISH SCHEDULE)
8. SEE DETAIL FOR TYP SUSPENDED GRID DETAIL..
9. INTERIOR WALLS ARE TYPICALLY 6" ABOVE CEILING HEIGHT SHOWN UNLESS NOTED
OTHERWISE ON ARCHITECTURAL OR STRUCTURAL DRAWINGS (i.e. SHEAR WALLS, SMOKE BARRIER WALLS, SOUND BARRIER WALLS, MECHANICAL ZONE WALLS).
10. COORDINATE LOCATION OF CEILING ACCESS DOORS WITH MECHANICAL &
ELECTRICAL CONTRACTORS.
11. PROVIDE ADDITIONAL EDGE BLOCKING, CROSS BRACING & SUSPENDED SUPPORT
WIRES OR ADDITIONAL FURRING FOR CEILING MOUNTED ITEMS (LIGHTING, ACCESS
PANELS, GRILLES, CAMERAS, ETC.)
FLAG NOTES TO REFLECTED CEILING PLAN:
OTS
MECHANICAL SUPPLY AIR GRILLE - REFER TO
MECH. FOR SIZE AND TYPE
MECHANICAL SUPPLY AIR GRILLE W/ 24"X24"
CEILING GRID SHROUD - REFER TO MECH. FOR
SIZE AND TYPE
MECHANICAL RETURN AIR GRILLE - REFER TO
MECH. FOR SIZE AND TYPE
MECHANICAL RETURN AIR GRILLE W/ 24"X24"
CEILING GRID SHROUD - REFER TO MECH. FOR
SIZE AND TYPE
MECHANICAL RETURN AIR GRILLE - REFER TO
MECH. FOR SIZE AND TYPE
24"X24" RECESSED CEILING
TROFFER - REFER TO ELECT.
24"X24" RECESSED CEILING TROFFER
W/ BATTERY BACK-UP POWER - REFER
TO ELECT
12"X48" RECESSED CEILING
TROFFER - REFER TO ELECT.
12"X48" RECESSED CEILING TROFFER W/
BATTERY BACK-UP POWER - REFER TO
ELECT.
12"X48" PENDANT LIGHTING -
REFER TO ELECT.
RECESSED CAN LIGHT -
REFER TO ELECT.
RECESSED CAN LIGHT W/ BATTERY
BACK-UP - REFER TO ELECT.
RECESSED SKYLITE TUBE W/
TAMPER PROOF
CEILING ACCESS PANEL
CEILING MOUNTED ILLUMINATED
EXIT SIGN
A
17' - 2"
17' - 2"
8' - 0"
9' - 0"
906 Columbia Street SW, Suite 400
Olympia, Washington 98501
360.352.8883 architects
KMB Project #
SHEET NO.
REVISIONS:
DATE:
ORIGINAL SHEET SIZE = 24 x 36
HALF SIZE REDUCTIONS = 11 x 17
P
LO
T D
A T
E
ARCHITECT
STATE OF WASHINGTON
REGISTERED
JAMES HILL
10347
/6 /2
0:
:0
A
M
03-10-2023
BID SET
A-152
LEVEL 1 - ENLARGED
REFLECTED CEILING PLAN
- BLDG 1
LE
W
IS
C
O U
N
TY
S
IT
E D
EV
EL
O P
M
EN
T
LE
W
IS
C O
U N
TY
F
A C
IL
IT
IE
S
D
EP
A R
TM
EN
T
N W
N O
R
TH
S
TR
EE
T, C H
EH
A
LI
S
, W A
Fa ci lit ie s D ep ar tm en t
J2037C
1/8" = 1'-0"1
LEVEL 1- ENLARGED REFLECTIVE CEILING PLAN - BLDG 1
REFLECTED CEILING PLAN NOTES
1/4" = 1'-0"2
LEVEL 1 - ENLARGED RCP - -VESTIBULE
| Sheets |
| A-152 - LEVEL 1 - ENLARGED REFLECTED CEILING PLAN - BLDG 1 |
File details come from the government source that posted it. Updated .