W

W

W

W

W

W

W

W

W

W

W

S

S

S

S

W

284TH

ST. N

W (W

AH

L R

D

EXISTING

SEWER MAIN

8" PVC

PROPOSED SEWER

SERVICE LINE

4"PVC

PROPOSED WATER

SERVICE LINE

1.5" HDPE

EXISTING

WATER MAIN

8" DUCTILE IRON

INSTALL CITY-PROVIDED

WATER METER IN

EXISTING METER BOX

EXISTING

SEWER

MAN HOLE

PROPOSED

SEWER

CLEANOUTS

ABANDON EXISTING

SEPTIC TANK

M

W

S

L

W S

L W

S L

W S

L W

S L

W S

L W

S L

W S

L W

S L

W S

L W

S L

W S

L W

S L

S

S

L

S

S

L

S

S

L

S

S

L

S S

L S

S L

S S

L S

S L

S S

L S

S L

S S

L

S S

L

S

S

L

S S

L

ABANDON

EXISTING

WELL

CONNECT PROPOSED SEWER

SERVICE LINE TO SEWER MAIN

JUST WEST OF OF MANHOLE

GARAGE

HOME

EXISTING DRAINFIELD

PROPERTY LINE

RIGHT-OF-WAY

EXISTING CLEANOUT, PROTECT

IN PLACE. CONNECT SSL JUST

AFTER CLEANOUT.

PATIO

U.S. PUBLIC HEALTH SERVICE

4060 WHEATON WAY - SUITE E

BREMERTON, WA 98310

(360) 792-1235

DATE REVISIONS INIT.

OLYMPIC DISTRICT OFFICE

CHECKED BY:

PROJ ENG:

DRAWN BY:

S H

E E

T

O F

S:\_ODO Projects\_Participants\Snoqualmie\Johnson, Mary Ellen\2 - Design\DWGS\Plans-Johnson-ServiceConn.dwg - Jun 23, 2020 - 3:32pm

APPROVED BY:

INDIAN HEALTH SERVICE

SANITATION FACILITIES CONSTRUCTION

PROJECT NO:

WATER AND SEWER SERVICE CONNECTIONS

7410 284TH ST. NW, STANWOOD, WA 98292

MARY ELLEN JOHNSON

SNOQUALMIE TRIBE

S. SCHATZ

IHS PROJECT NO. PO-19-C42M

H. ANDINA

C

NOTES:

1. PROPOSED WATER AND SEWER

SERVICE LINES SHALL BE

INSTALLED IN TRENCHES

ALONGSIDE THE DRIVEWAY.

CONTRACTOR SHALL POTHOLE AS

NEEDED TO LOCATE EXISTING

UTILITIES.

2. WATER SERVICE LINE TO BE

CONNECTED TO EXISTING

STUB-OUT ON HOME.

3. NO SINGLE SEWER SERVICE LINE

BEND SHALL EXCEED 45 DEG.

4. SEWER SERVICE LINE SHALL HAVE

A MINIMUM 2% DOWNHILL SLOPE.

5. SEPTIC TANK, DRAINFIELD, AND

EXISTING CLEANOUT LOCATIONS

ARE APPROXIMATE.

ALL PROPERTY LINES AND DIMENSIONS AS SHOWN ARE FROM INFORMATION

SUPPLIED BY THE CLIENT. THE DESIGNERS ASSUME NO LIABILITY FOR

VARIATIONS ASCERTAINED BY ACTUAL SURVEY. ALL ELEVATIONS ARE

APPROXIMATE AND SHOULD NOT BE USED FOR DESIGN PURPOSES.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1 INCH = 50 FEET

AutoCAD SHX Text n

AutoCAD SHX Text

NOTE: THIS IS NOT A SURVEY

U S

P

U B

L I C

H

E A

L T

H

S

E R

V I C

E

W

H E

A T

O N

A Y

S

U I T

E

E

B R

E M

E R

T O

N

A

D A

T E

R E

V I S

I O

N S

I N

I T

O L Y

M P

D

S

T R

I C

T

O

F F

I C

E

C H

E C

K E

D

B

Y

P R

O J

E

N G

R

A W

N

B

SHEET

OF

S O

P r o j e c t s P a r t i c i p a n t s S n o q u a l m i e J o h n s o n

M a r y

E l l e n

D e s i g n D

W G

S P l a n s J o h n s o n S e r v i c e C o n n d w g

J u n p m

A P

P R

O V

B

I N

D I A

N

H

E A

L T

H

S

E R

V I C

E

S A

N I T

A T

I O

N

F

A C

I L I T

I E

S

C

O N

S T

R U

C T

I O

N

P R

O J E

T

D E

T A

I L S

T

H

S

T

N

W

S

T A

N W

O O

D

W

A

M A

L L E

N

J O

H N

S O

N

S N

O Q

U A

L M

I B

E

S

S

C H

A T

Z

I H

S

P

R O

J E

P

O

-H

A

N D

I N

A

C-501

2 2

AutoCAD SHX Text

DOUBLE SWEEP SEWER SERVICE CLEANOUT NOT TO SCALE

AutoCAD SHX Text

4" DOUBLE SWEEP C/O

AutoCAD SHX Text

4" DIAMETER PVC PIPE

AutoCAD SHX Text

4" PVC PIPE

AutoCAD SHX Text

12" X 12" X 3" CONCRETE PAD

AutoCAD SHX Text

SCHEDULE 40 PVC ADAPTER AND THREADED PLUG

AutoCAD SHX Text

3' LIFT OF SAND

Sheets and Views
Plans-Johnson-ServiceConn-SITE PLAN
Plans-Johnson-ServiceConn-DETAILS

File details come from the government source that posted it. Updated .