This document contains draft asbestos reports for building 51424 along with details of a related federal contract opportunity for the renovation of buildings 51424 and 51428. The asbestos reports analyze 14 bulk samples from building 51424 using polarized light microscopy to identify and quantify any asbestos present in each sample layer according to EPA methods. Any layer containing over 1% asbestos is considered positive. The contract opportunity is a pre-solicitation notice from the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground for renovations to the two buildings but does not provide specifics on required products or services, pricing terms, or response dates.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFT
Client Job: 1-1563204 PO Number: 51424
JobNumber: 201300607
Routing Number: -
# Samples: 14
PLMn
PLM The "New" Method; see below
Client:
Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample
Method and Analysis Information:
Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.
Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."
The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40CFT Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US
EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are <= 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0- 5%. This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or
"negative". For this reason, Fiberquant refers to results where asbestos was detected but <= 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.
Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope (TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.
The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that
Method: EPA 600/R-93/116Rec: 1/17/2013
Report Date: 1/23/2013 Date Analyzed: 1/23/2013
Fiberquant Internal SOP:
EMCOR GOVERNMENT SVCS
CLARKSTON RD BLDG 30033
FT HUACHUCA, AZ
Office Phone: (520) 533-5906
FAX: (520) 533-3699
85613-0000
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 1 of 8
PLM Analysis Summary: Job Number: 201300607 1-1563204 analysts can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab
#101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical Services.
Job Analysis Notes:
Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.
Sample Number Lab Number Apparent Sample Type * Positive Layer Yes or No
Layer Color Apparent Layer Type * Asbestos Results
Flooring2013-00607- 151424-01 Positive Layer? YesSample # 5-10% chrysotile asbestosfloor tileoff-whiteLayer # 1 no asbestos detectedmasticbrownLayer # 2
Adhesive/caulk2013-00607- 251424-02 Positive Layer? NoSample # <=1% chrysotile asbestosputtygrayLayer # 1
Adhesive/caulk2013-00607- 351424-03 Positive Layer? NoSample # no asbestos detectedpaintblackLayer # 1 no asbestos detectedsealantoff-whiteLayer # 2
Adhesive/caulk2013-00607- 451424-04 Positive Layer? NoSample # no asbestos detectedpaintblackLayer # 1 no asbestos detectedsealantoff-whiteLayer # 2
Adhesive/caulk2013-00607- 551424-05 Positive Layer? NoSample # no asbestos detectedputtygrayLayer # 1
Cementitious2013-00607- 651424-06 Positive Layer? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedgroutgrayLayer # 2
Adhesive/caulk2013-00607- 751424-07 Positive Layer? NoSample # no asbestos detectedpaintoff-whiteLayer # 1
<=1% chrysotile asbestosputtyoff-whiteLayer # 2
Miscellaneous2013-00607- 851424-08 Positive Layer? NoSample # no asbestos detectedbase coveblackLayer # 1 no asbestos detectedmasticoff-whiteLayer # 2
Flooring2013-00607- 951424-09 Positive Layer? NoSample # no asbestos detectedfloor tileblackLayer # 1 no asbestos detectedmastictanLayer # 2
Insulation2013-00607- 1051424-10 Positive Layer? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedinsulation wrapoff-whiteLayer # 2
Flooring2013-00607- 1151424-11 Positive Layer? NoSample # no asbestos detectedfloor tileblackLayer # 1 no asbestos detectedmastictanLayer # 2
Adhesive/caulk2013-00607- 1251424-12 Positive Layer? YesSample # 2-5% chrysotile asbestoscaulkblackLayer # 1 no asbestos detectedbitumenblackLayer # 2
Adhesive/caulk2013-00607- 1351424-13 Positive Layer? YesSample # no asbestos detectedbitumenblackLayer # 1
5-10% chrysotile asbestoscaulkblackLayer # 2
Adhesive/caulk2013-00607- 1451424-14 Positive Layer? NoSample # no asbestos detectedbitumenblackLayer # 1 no asbestos detectedroof plyblackLayer # 2 no asbestos detectedroof plyblackLayer # 3 no asbestos detectedroof ply/bitumenblackLayer # 4 no asbestos detectedroof ply/bitumenblackLayer # 5 no asbestos detectedroof ply/bitumenblackLayer # 6 no asbestos detectedroof ply/bitumenblackLayer # 7 no asbestos detectedroof ply/bitumenblackLayer # 8 no asbestos detectedroof plyblackLayer # 9 no asbestos detectedfoamyellowLayer # 10
* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the apparent type of material may not be the actual type of material.
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 2 of 8
PLM Analysis Details Job Number: 201300607 1-1563204
2013-00607- 151424-01 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Flooring
No
Non-fibrous SolidOKAn?
2# Layers YesPos Layer?
Apparent Smp Type chrysotile asbestos Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of floor tile matrix and mastic using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
1.561 1.553chrysotile asbestos
1.550 db/ly sb/oW A N N L + P
Non-Fibrous Components (in approx. decreasing order): polymer, filler, 6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 92 5-10% - - - - -floor tile off-white 1
2 8 n.d. - - - - -mastic brown 1
100Total % 5-10% - - - - -Overall %
2013-00607- 251424-02 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
Yes
Non-fibrous SolidOKAn?
1# Layers NoPos Layer?
Apparent Smp Type chrysotile asbestosFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
1.561 1.553chrysotile asbestos 1.550 db/ly sb/oW A N N L + P
Non-Fibrous Components (in approx. decreasing order): filler, binder, 3# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 100 <=1% - - - - -putty gray 1
100Total % <=1% - - - - -Overall %
2013-00607- 351424-03 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
RubberyOKAn?
2# Layers NoPos Layer?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
5# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. - - - - -paint black 1
2 98 n.d. - - - - -sealant off-white 1
100Total % n.d. - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 3 of 8
2013-00607- 451424-04 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
RubberyOKAn?
2# Layers NoPos Layer?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
4# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 0.5 n.d. - - - - -paint black 1
2 99.5 n.d. - - - - -sealant off-white 1
100Total % n.d. - - - - -Overall %
2013-00607- 551424-05 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
Yes
Non-fibrous SolidOKAn?
1# Layers NoPos Layer?
Apparent Smp Type noneFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
Non-Fibrous Components (in approx. decreasing order): filler, binder, 3# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 100 n.d. - - - - -putty gray 1
100Total % n.d. - - - - -Overall %
2013-00607- 651424-06 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Cementitious
No
Non-fibrous SolidOKAn?
2# Layers NoPos Layer?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
Non-Fibrous Components (in approx. decreasing order): powder, rock, polymer
6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 45 n.d. - - - - -paint off-white 1
2 55 n.d. - - - - -grout gray 2
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 4 of 8
2013-00607- 751424-07 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
Non-fibrous SolidOKAn?
2# Layers NoPos Layer?
Apparent Smp Type chrysotile asbestos Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
1.561 1.553chrysotile asbestos
1.550 db/ly sb/oW A N N L + P
5# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 10 n.d. - - - - -paint off-white 1
2 90 <=1% - - - - -putty off-white 1
100Total % <=1% - - - - -Overall %
2013-00607- 851424-08 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Miscellaneous
No
RubberyOKAn?
2# Layers NoPos Layer?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent. Minor adhering wall paint and/or texture, etc. not analyzed.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
5# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 95 n.d. - - - - -base cove black 1
2 5 n.d. - - - - -mastic off-white 1
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 5 of 8
2013-00607- 951424-09 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Flooring
No
Non-fibrous SolidOKAn?
2# Layers NoPos Layer?
Apparent Smp Type cellulose fiber Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of floor tile matrix and mastic using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber
W F N N H + U
Non-Fibrous Components (in approx. decreasing order): filler, polymer, 6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 92 n.d. - - - - -floor tile black 1
2 8 <=1% - - - - -mastic tan 1
100Total % <=1% - - - - -Overall %
2013-00607- 1051424-10 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Insulation
No
Fibrous SolidOKAn?
2# Layers NoPos Layer?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): polymer, metal, binder
5# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 50 n.d. n.d. - - - -paint off-white 1
2 50 30-40% 10-20% - - - -insulation wrap off-white 2
100Total % 10-20% 5-10% - - - -Overall %
2013-00607- 1151424-11 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Flooring
No
Non-fibrous SolidOKAn?
2# Layers NoPos Layer?
Apparent Smp Type cellulose fiber Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of floor tile matrix and mastic using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber
W F N N H + U
6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 95 n.d. - - - - -floor tile black 1
2 5 <=1% - - - - -mastic tan 1
100Total % <=1% - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 6 of 8
2013-00607- 1251424-12 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
Non-fibrous SolidOKAn?
2# Layers YesPos Layer?
Apparent Smp Type chrysotile asbestosFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
1.561 1.553chrysotile asbestos 1.550 db/ly sb/oW A N N L + P
Non-Fibrous Components (in approx. decreasing order): bitumen, filler, rock
6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 80 2-5% - - - - -caulk black 1
2 20 n.d. - - - - -bitumen black 1
100Total % 2-5% - - - - -Overall %
2013-00607- 1351424-13 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
Non-fibrous SolidOKAn?
2# Layers YesPos Layer?
Apparent Smp Type chrysotile asbestosFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
1.561 1.553chrysotile asbestos 1.550 db/ly sb/oW A N N L + P
Non-Fibrous Components (in approx. decreasing order): bitumen, filler, 6# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 20 n.d. - - - - -bitumen black 1
2 80 5-10% - - - - -caulk black 1
100Total % 5-10% - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 7 of 8
2013-00607- 1451424-14 Lab Number Sample Sampled:
MACAnalyzed By 1/23/2013
Homogeneous
Adhesive/caulk
No
Fibrous SolidOKAn?
10# Layers NoPos Layer?
Apparent Smp Type cellulose fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. Note: due to damaged condition, unable to accurately determine number or sequence of layers.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber W F N N H + U
Non-Fibrous Components (in approx. decreasing order): bitumen, filler, 20# Sub-Samples
Condition: acceptable
Layers
# Layer Type % Color Friability
Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 10 n.d. - - - - -bitumen black 1
2 2 50-60% - - - - -roof ply black 1
3 4 50-60% - - - - -roof ply black 1
4 7 40-50% - - - - -roof ply/bitumen black 1
5 7 40-50% - - - - -roof ply/bitumen black 1
6 8 50-60% - - - - -roof ply/bitumen black 1
7 8 50-60% - - - - -roof ply/bitumen black 1
8 12 50-60% - - - - -roof ply/bitumen black 1
9 12 50-60% - - - - -roof ply black 1
10 30 n.d. - - - - -foam yellow 3
100Total % 30-40% - - - - -Overall %
Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable
Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various
Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;
D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper
Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High
Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining
Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow;
vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.
RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber
23-Jan-13Analyst: MICHAEL A. COOK
Larry S. Pierce, Approved Accreditation Signatory
Printed:
23-Jan-13Original Print Date:
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 8 of 8
| 201300607-51424-interior-and-Roof |
| 51424-SP-ACM-LBP-Int-Roof |
File details come from the government source that posted it. Updated .