J.3 Project Location.Drawings.Maps (5 Pages).pdf

PDF 3 MB Posted

Attached to
Forest Wide HVAC and Piping Federal contract opportunity
Solicitation number
1240LT25Q0024
Issued by
Department of Agriculture Forest Service

About this file

This file is a set of project location drawings and maps for a Forest Wide HVAC and Piping project in the Dixie National Forest, Garfield County, Utah. The five-page document includes site plans and HVAC details for three dwellings in Panguitch (North, Middle, and South Dwellings) and two locations in Escalante (Dwelling #2 and a 10-Person Bunkhouse). The project scope involves replacing existing galvanized steel piping with PEX piping, replacing associated fixtures, repairing finishes, and retrofitting these buildings with central cooling systems. Each location has specific HVAC and plumbing fixture replacement schedules, detailing the equipment to be installed, such as 3-ton high-efficiency heat pumps, indoor coils, and various plumbing fixtures like kitchen sink faucets and shower valves. The project is estimated to cost between $100,000 and $250,000, with performance and payment bonds required depending on the final contract value.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOREST LOCATION MAP

PROJECT LOCATION MAP

TRAVEL DIRECTIONS:

SHEET OF

United States Department of Agriculture Forest Service

FOREST WIDE HVAC AND PIPING

PANGUITCH NORTH DWELLING: 33 NORTH 425 WEST, PANGUITCH, UTAH 84759

PANGUITCH MIDDLE DWELLING: 19 NORTH 425 WEST, PANGUITCH, UTAH 84759

PANGUITCH SOUTH DWELLING: 1 NORTH 425 WEST, PANGUITCH, UTAH 84759

ESCALANTE DWELLING #2: 87 EAST 200 NORTH, ESCALANTE, UTAH 84726

ESCALANTE 10 PERSON BUNKHOUSE: 750 WEST MAIN STREET, ESCALANTE, UTAH 84726

RECOMMENDED BY:

APPROVED:

FOREST ENGINEER

DISTRICT RANGER DATE

DATE

FOREST SUPERVISOR DATE

DISTRICT RANGER DATE

1/6 /25

:4

6 J

DO

DD

S

C:

\U

SE

RS

\JD

OD

DS

\O

NE

DR

IV

E

- U

SD

A\

DO

CU

ME

NT

S\

PR

OJ

EC

TS

\F

OR

ES

T

W

ID

E\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G.

DW

G;

UTAH

GARFIELD COUNTY

(R04) INTERMOUNTAIN REGION

DIXIE NATIONAL FOREST

POWELL AND ESCALANTE RANGER DISTRICTS

INDEX OF SHEETS

SHEET SHEET TITLE DATE

G-01 COVERSHEET 1/20/2025

C-01 SITE PLAN - PANGUITCH 1/20/2025

C-02 SITE PLAN - ESCALANTE 1/20/2025

D-01 HVAC AND PLUMBING DETAILS - PANGUITCH 1/20/2025

D-02 HVAC DETAILS - ESCALANTE 1/20/2025

CEDAR CITY

PANGUITCH

ESCALANTE

W CENTER STREET

N 425 W

PP

PP

PP

PP

PP

PP

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

1/4 /25

:5

4 J

DO

DD

S

C:

\U

SE

RS

\JD

OD

DS

\O

NE

DR

IV

E

- U

SD

A\

DO

CU

ME

NT

S\

PR

OJ

EC

TS

\F

OR

ES

T

W

ID

E\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G.

DW

G;

R04

INTERMOUNTAIN REGION

FOREST WIDE

HVAC AND PIPING

DIXIE NATIONAL FOREST

ESCALANTE AND POWELL RANGER

DISTRICTS

SITE PLAN - PANGUITCH

01/20/2025

J. DODDS

J. DODDS

K. LOUCKS

C-01 2 5

PANGUITCH NORTH DWELLING

MAIN FLOOR 1200 SQUARE FEET

LEGEND

EXISTING BUILDING

CONCRETE

EXISTING FENCE

ROADS

PANGUITCH MIDDLE DWELLING

MAIN FLOOR 1050 SQUARE FEET

PANGUITCH SOUTH DWELLING

MAIN FLOOR 1200 SQUARE FEET

PANGUITCH ADMIN SITE PLAN

425 WEST CENTER STREET, PANGUITCH UTAH

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

SCALE IN FEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING

PICNIC

AREA

WAREHOUSE

RETENTION

POND

TREE COOLER AND

WRAPPING SHED

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

1/4 /25

:5

4 J

DO

DD

S

C:

\U

SE

RS

\JD

OD

DS

\O

NE

DR

IV

E

- U

SD

A\

DO

CU

ME

NT

S\

PR

OJ

EC

TS

\F

OR

ES

T

W

ID

E\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G.

DW

G;

R04

INTERMOUNTAIN REGION

FOREST WIDE

HVAC AND PIPING

DIXIE NATIONAL FOREST

ESCALANTE AND POWELL RANGER

DISTRICTS

SITE PLAN - ESCALANTE

ADMIN

01/20/2025

J. DODDS

J. DODDS

K. LOUCKS

C-02 3 5

LEGEND

EXISTING BUILDING

CONCRETE

EXISTING FENCE

ROADS

WAREHOUSE SITE PLAN

165 N 700 W, ESCALANTE UT

10 PERSON BUNKHOUSE

SEE SHEET 5 FOR HVAC WORK DETAILS

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

SCALE IN FEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

1/4 /25

:5

4 J

DO

DD

S

C:

\U

SE

RS

\JD

OD

DS

\O

NE

DR

IV

E

- U

SD

A\

DO

CU

ME

NT

S\

PR

OJ

EC

TS

\F

OR

ES

T

W

ID

E\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G.

DW

G;

R04

INTERMOUNTAIN REGION

FOREST WIDE

HVAC AND PIPING

DIXIE NATIONAL FOREST

ESCALANTE AND POWELL RANGER

DISTRICTS

HVAC AND PLUMBING

DETAILS - PANGUITCH

01/20/2025

J. DODDS

J. DODDS

K. LOUCKS

D-01 4 5

PANGUITCH NORTH DWELLING

PANGUITCH MIDDLE DWELLING

PANGUITCH SOUTH DWELLING

ITEM

TUB/SHOWER

LAVATORY FAUCET

KITCHEN SINK FAUCET

NO. REQ'D DESCRIPTION - SEE NOTE BELOW

INSTALL NEW ROUGH IN MOEN POSI TEMP VALVE. FAUCET WILL NOT BE REPLACED.

REPLACE WITH CHROME SINGLE HANDLE MOEN BUILDER GRADE.

REPLACE WITH CHROME SINGLE HANDLE MOEN BUILDER GRADE.

PLUMBING FIXTURE REPLACEMENT SCHEDULE

ITEM

NORTH DWELLING

MAIN FLOOR

NORTH DWELLING

BASEMENT

MIDDLE DWELLING

MAIN FLOOR

KITCHEN FAUCET

R

EXISTING PLUMBING FIXTURES

WATER CLOSET TUB / SHOWER LAVATORY FAUCET WASHING MACHINE WATER HEATER

MIDDLE DWELLING

BASEMENT

SOUTH DWELLING

MAIN FLOOR

SOUTH DWELLING

BASEMENT

R

R

X X R

X

WASH SINK

X XX R

X X R

X X

X X R X

X

ITEM

3 TON HIGH EFFICIENCY

HEAT PUMP

24K BTU INDOOR COIL

HEAT PUMP STAND 12"

EQUIPMENT PAD

COPPER INSULATED LINE

SET

2 STAGE HEAT COOLING

THERMOSTAT

NO. REQ'D DESCRIPTION - SEE NOTE BELOW

OUTDOOR UNIT M# FLEXX36HP230V1AO

COIL AND ENCLOSURE M# FLEXX24C

50'

WITH INTEGRATION FOR THE SECOND STAGE BEING THE EXISTING FURNACE

HVAC SCHEDULE

NOTE: MANUFATURES NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH REQUIRED FUNCTION AND ACCEPTABLE QUALITY.

EQUIVALENT PRODECT OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.

NOTES:

1. PIPING NOTES

1.1. ABANDON GALVANIZED AND COPPER WATER SUPPLY LINES THROUGHOUT THE HOUSE AND REPLACE WITH PEX.

1.1.A. EXISTING PLUMBING FIXTURES ARE SHOWN AS A REFERENCE TO ESTIMATE NUMBER OF CONNECTIONS.

1.2. ADAPT FROM GALVANIZED PIPE TO PEX AT MAINLINE ENTRANCE TO INTERIOR OF HOME IN THE BASEMENT.

1.2.A. INSTALL NEW SHUTOFF VALVE AND PRESSURE REDUCING VALVE.

1.3. REPLACE THOSE FIXTURES / VALVES LISTED IN THE PLUMBING FIXTURE REPLACEMENT SCHEDULE.

1.4. CONTRACTOR RESPONSIBLE FOR PIPE AND ALL NEEDED SUPPLIES

1.5. REPAIR ALL INTERIOR FINISHES TO MATCH ORIGINAL

1.6. ABANDON WATER LINES TO INCOMPLETE BASEMENT BATHROOM IN SOUTH DWELLING.

2. HVAC NOTES

2.1. PROVIDE ALL LABOR AND MATERIALS TO RETROFIT EXISTING HVAC SYSTEM WITH CENTRAL COOLING.

2.1.A. ANTICIPATED EQUIPMENT IS SHOWN IN THE HVAC SCHEDULE.

NOTE: ITEMS MARKED AS "R" SHALL BE REPLACED. ITEMS MARKED AS "X" ARE FOR REFERENCE ONLY.

NOTE: MANUFATURES NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH REQUIRED FUNCTION AND ACCEPTABLE QUALITY.

EQUIVALENT PRODECT OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

E

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

1/6 /25

:4

6 J

DO

DD

S

C:

\U

SE

RS

\JD

OD

DS

\O

NE

DR

IV

E

- U

SD

A\

DO

CU

ME

NT

S\

PR

OJ

EC

TS

\F

OR

ES

T

W

ID

E\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G\

FO

RE

ST

W

ID

E

HV

AC

A

ND

P

IP

IN

G.

DW

G;

R04

INTERMOUNTAIN REGION

FOREST WIDE

HVAC AND PIPING

DIXIE NATIONAL FOREST

ESCALANTE AND POWELL RANGER

DISTRICTS

HVAC DETAILS -

ESCALANTE

01/20/2025

J. DODDS

J. DODDS

K. LOUCKS

D-02 5 5

10 PERSON BUNKHOUSE

750 WEST MAIN STREET, ESCALANTE, UTAH

ESCALANTE DWELLING #2

87 EAST 200 NORTH, ESCALANTE, UTAH

ITEM

3 TON HIGH EFFICIENCY

HEAT PUMP

24K BTU INDOOR COIL

HEAT PUMP STAND 12"

EQUIPMENT PAD

COPPER INSULATED LINE

SET

2 STAGE HEAT COOLING

THERMOSTAT

NO. REQ'D DESCRIPTION - SEE NOTE BELOW

OUTDOOR UNIT M# FLEXX36HP230V1AO

COIL AND ENCLOSURE M# FLEXX24C

50'

WITH INTEGRATION FOR THE SECOND STAGE BEING THE EXISTING FURNACE

HVAC SCHEDULE - ESCALANTE DWELLING #2

NOTE: MANUFATURES NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH REQUIRED FUNCTION AND ACCEPTABLE QUALITY.

EQUIVALENT PRODECT OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.

NOTES:

1. HVAC NOTES

1.1. PROVIDE ALL LABOR AND MATERIALS TO RETROFIT EXISTING HVAC SYSTEMS WITH CENTRAL COOLING.

1.1.A. ANTICIPATED EQUIPMENT IS SHOWN IN THE HVAC SCHEDULE.

ITEM

42K BTU HIGH HEAT, HIGH

EFFICIENCY HEAT PUMP

18K BTU CEILING

MOUNTED CASSETTE

CASSETTE GRILL

12K BTU HIGH WALL

MOUNT UNIT

COPPER INSULATED LINE

SET 14 X1

CRIMP-ON FLARES FOR

INDOOR AND OUTDOOR

UNITS

HEAT PUMP STAND 12"

EQUIPMENT PAD

ELECTRICAL SUPPLIES

AND CONNECTORS

NO. REQ'D DESCRIPTION - SEE NOTE BELOW

MULTI42HP230V1EO MULTIGEN2

GREE CAS18HP230V1BC

GREE 3V1R12HP230V1AH

4" 12" CRIMP FLARE PAIRS

POWER DISCONNECT 2 INCLUDES POWER LEAD

COMMUNICATION CABLE POWER CABLE FOR HEADS

PLASTIC PAD

NOTE: MANUFATURES NAMES AND MODEL NUMBERS ARE GIVEN TO ESTABLISH REQUIRED FUNCTION AND ACCEPTABLE QUALITY.

EQUIVALENT PRODECT OF OTHER MANUFACTURERS MAY BE SUBMITTED FOR REVIEW AND APPROVAL.

HVAC SCHEDULE - 10 PERSON BUNKHOUSE

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

E

FOREST WIDE HVAC AND PIPING-1
Sheets and Views
FOREST WIDE HVAC AND PIPING-1
OLE1
FOREST WIDE HVAC AND PIPING-2
Sheets and Views
FOREST WIDE HVAC AND PIPING-2
OLE1
FOREST WIDE HVAC AND PIPING-3
Sheets and Views
FOREST WIDE HVAC AND PIPING-3
OLE1
FOREST WIDE HVAC AND PIPING-4
Sheets and Views
FOREST WIDE HVAC AND PIPING-4
FOREST WIDE HVAC AND PIPING-5
Sheets and Views
FOREST WIDE HVAC AND PIPING-5
2025-01-06T15:02:49-0700
STEVEN ONEIL
2025-01-06T13:07:50-0700
CHRISTOPHER WEHRLI
2025-01-06T15:32:05-0700
RICHARD STEWART
2025-01-06T15:10:52-0700
KEVIN WRIGHT

File details come from the government source that posted it. Updated .