About this file
This document is a chain of custody and asbestos analysis order form for bulk building materials collected at the U.S. Government Publishing Office (USGPO) located at 732 North Capitol Street NW, Washington, DC. The order was issued by EMSL Analytical, Inc. on April 12, 2022, with analysis completed on April 13, 2022. The primary contact is Daryl Kosturock at the USGPO Safety Branch.
A single sample (2022041208) of red/black brick flooring from room B-543/Floor was analyzed using polarized light microscopy (PLM) per EPA 600/R-93/116 methodology. The analysis detected no asbestos content. The sample composition consisted of 25% quartz, 30% gypsum, and 45% non-fibrous other materials. The document also includes supplementary environmental survey reports dated August 26, 2021, documenting a limited asbestos survey of rooms T251, B543, and B542 conducted by Arc Environmental, LLC. That survey collected 17 bulk samples from six suspect homogeneous areas, with all samples testing negative for asbestos. Additionally, baseline carbon black surface sampling and lead-in-paint analysis were performed on July 14, 2021, identifying lead concentrations ranging from 0.041% to 13% by weight across various painted surfaces and components within the three rooms. The survey recommended that any additional suspect materials uncovered during renovation activities be assumed to contain asbestos and sampled accordingly.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| J.1 Adhesive Room Conceptual Drawings.pdf | ||
| J.2 Adhesive Room Layout.pdf | ||
| J.9 Image.pdf | ||
| J.10 Image.pdf | ||
| 040ADV-26-R-0012.pdf | ||
| J.4 Wage Determination.pdf | ||
| J.6 Creating Adobe PDF Porfolio.pdf | ||
| J.5 Past Performance Questionnaire.pdf | ||
| J.7 Image.pdf | ||
| J.8 Image.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OrderID: 192202592
EMSL Analytical, Inc.
10752 Baltimore Avenue Beltsville, MD 20705
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
192202592EMSL Order:
Customer ID: USGPO80
Customer PO:
Project ID:
Attention: Phone:Daryl Kosturock (202) 512-1626
Fax:US Govt Publishing Office Safety Branch (202) 512-1034
Received Date:732 North Capitol Street NW 04/13/2022 10:00 AM
Analysis Date:Washington, DC 20401 04/13/2022
Collected Date: 04/12/2022
Project: 20220412B543
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
2022041208
192202592-0001
None DetectedQuartz
Gypsum
Non-fibrous (Other)
25%
30%
45%
Red/Black
Non-Fibrous
Homogeneous
B-543/ FLOOR/ RED/
BLACK BRICK
FLOORING
Analyst(s)
Camryn Collette (1) Joe Centifonti, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Beltsville, MD NVLAP Lab Code 200293-0
Initial report from: 04/13/2022 11:40:02
Page 1 of 1ASB_PLM_0008_0001 - 1.78 Printed: 4/13/2022 11:40 AM