View the file

Other files

File Type Posted
Amendment 0001_2022-06-03_RFQ N66604-22-Q-0395 B447 Painting and Abatement_Conformed.pdf PDF
J-3. B447 Surface Areas Calculations Chart_Revised-2022-06-02.pdf PDF
Amendment 0001_2022-06-03_RFQ N66604-22-Q-0395 B447 Painting and Abatement_Summary Changes.pdf PDF
J-17. B447 Lead Sample Results - 2019.pdf PDF
J-10. Wage Determination RI20220001_Mod 6_2022-05-27.pdf PDF
J-3. B447 Surface Areas Calculations Chart.pdf PDF
J-10. Wage Determination RI20220001_Mod 5_2022-05-06.pdf PDF
J-17. Indication of Interest_Optional.docx DOCX document
J-11. List of Key Personnel.docx DOCX document
J-12. Visitor Request Instructions and Information Needed_2021-08.pdf PDF
J-6. Lead Paint Training ECATTS Guide 2021.pdf PDF
J-13. SECNAV Form 5512_NSNPT_2019-07.pdf PDF
J-14. Consolidated DoD COVID-19 Guidance.PDF PDF
J-8. B447 Section 02 83 00 Lead Remediation.pdf PDF
RFQ N66604-22-Q-0395 B447 Painting and Lead Abatement.pdf PDF
J-9. Naval Station Newport Instruction 5090.9C Lead Paint Program.pdf PDF
J-16. COVID-19 Questionnaire.pdf PDF
J-5. B447 Lead and Asbestos Results - 2022.pdf PDF
J-2. B447 Reference Photos.pdf PDF
J-15. DD Form 3150 - Certification of Vaccination - v2 - BLANK.pdf PDF
J-7. Asbestos Training ECATTS Guide 2021.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINAL ASBESTOS-CONTAINING MATERIALS SURVEY

BUILDING 447 - NAVY GATEWAY INNS AND SUITES (NGIS)

NAVAL STATION NEWPORT

NEWPORT, NEWPORT COUNTY, RHODE ISLAND

CDM-AECOM MULTIMEDIA JOINT VENTURE

CONTRACT NUMBER: N62470-14-D-9016

TASK ORDER: WE45

PREPARED FOR:

CDM Federal Programs Corporation 10560 Arrowhead Drive, Suite 500

Fairfax, Virginia 22030

(703) 691-6500

And

Naval Facilities Engineering Command Mid-Atlantic Naval Station Newport

PREPARED BY:

Aerostar SES LLC 11181 St. Johns Industrial Parkway North

Jacksonville, Florida 32246

(904) 565-2820

Aerostar Project # M3010.1567.0001.17

September 28, 2018

SIGNATURE OF ENVIRONMENTAL PROFESSIONALS

This is to certify that the Final Report for the Asbestos-Containing Materials Survey of Building 447, Navy Gateway Inns and Suites (NGIS), located at Naval Station Newport, Newport, Newport County, Rhode Island, has been examined by the undersigned.

DATE: September 28, 2018 SIGNATURE:

Miles Eckert Aerostar SES LLC RIDH Asbestos Inspector Certification No. AAC-1004

DATE: September 28, 2018 SIGNATURE:

John H. Hubbard Jr., CSP, LAC Aerostar SES LLC Senior Project Manager RIDH Asbestos Inspector Certification No. AAC-1001

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page i

TABLE OF CONTENTS

SIGNATURE OF ENVIRONMENTAL PROFESSIONALS

LIST OF ABBREVIATIONS ..................................................................................................... iii

1.0 EXECUTIVE SUMMARY

1.1 Site Name

1.2 Name and Certifications of Inspector(s)

1.3 Site Description and Activities

1.4 Findings and Results

2.0 INTRODUCTION

2.1 Building Description

2.2 Historical Research

3.0 REGULATORY SUMMARY

3.1 Environmental Protection Agency

3.2 Occupational Safety and Health Administration

3.3 State of Rhode Island

4.0 METHODS OF INVESTIGATION

5.0 RESULTS

6.0 LIMITATIONS

7.0 CONCLUSIONS AND RECOMMENDATIONS

TABLE

TABLE 1 Summary of Asbestos Survey

FIGURES

FIGURE 1 Homogeneous Area Sample Locations – Basement FIGURE 2 Homogeneous Area Sample Locations – First Floor FIGURE 3 Homogeneous Area Sample Locations – Second Floor FIGURE 4 Homogeneous Area Sample Locations – Third Floor FIGURE 5 Homogeneous Area Sample Locations – Fourth Floor FIGURE 6 Homogeneous Area Sample Locations – Roof FIGURE 7 Asbestos-Containing Materials Locations – Basement FIGURE 8 Asbestos-Containing Materials Locations – First Floor FIGURE 9 Asbestos-Containing Materials Locations – Second Floor FIGURE 10 Asbestos-Containing Materials Locations – Third Floor FIGURE 11 Asbestos-Containing Materials Locations – Fourth Floor FIGURE 12 Asbestos-Containing Materials Locations – Roof

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page ii

APPENDICES

APPENDIX A Certifications APPENDIX B Laboratory Analytical Results APPENDIX C Photographic Documentation

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page iii

LIST OF ABBREVIATIONS

ACM Asbestos-Containing Materials Aerostar Aerostar SES LLC CFR Code of Federal Regulations DOT Department of Transportation EMSL EMSL Analytical, Inc.

EPA Environmental Protection Agency EPDM Ethylene Propylene Diene Monomer HAs Homogeneous Areas HVAC Heating, Ventilation, and Air Conditioning NAVSTA Newport Naval Station Newport NESHAP National Emission Standards for Hazardous Air Pollutants NGIS Navy Gateway Inns and Suites NIST National Institute of Standards and Technology NOB Non-friable Organically Bound NVLAP National Voluntary Laboratory Accreditation Program OSHA Occupational Safety and Health Administration PLM Polarized Light Microscopy RACM Regulated Asbestos-Containing Material RIDH State of Rhode Island and Providence Plantations Department of Health TEM Transmission Electron Microscopy TSI Thermal System Insulation VFT Vinyl Floor Tile

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 1

1.0 EXECUTIVE SUMMARY

1.1 Site Name

Building 447 Navy Gateway Inns and Suites (NGIS) Naval Station Newport Newport, Newport County, Rhode Island

1.2 Name and Certifications of Inspector(s)

Miles Eckert Dylan Hales RIDH Asbestos Inspector RIDH Asbestos Inspector Certification No. AAC-1004 Certification No. AAC-1032

Christopher Sweetman RIDH Asbestos Inspector Certification No. AAC-1033

1.3 Site Description and Activities

On January 16 and 17, and June 12, 2018; Aerostar SES LLC (Aerostar) conducted an Asbestos- Containing Materials (ACM) Survey of Building 447, located at Naval Station Newport (NAVSTA Newport), Newport, Newport County, Rhode Island. The survey included all accessible areas throughout the building’s exterior and interior.

1.4 Findings and Results

The following summarizes the findings throughout the building and identifies classifications of material requiring special handling:

Building Friable ACM Non-friable Category I

ACM

Non-friable Category II

ACM

Material Containing <1%

Asbestos

447 - NGIS No Yes* Yes* Yes*

* Materials must be handled in accordance with 40 CFR 61 Subpart M and 29 CFR 1926.1101

State of Rhode Island and Providence Plantations Department of Health (RIDH)-licensed Asbestos Inspectors conducted an asbestos survey of Building 447 to identify the locations, quantities, and conditions of ACMs. The asbestos survey was performed throughout all accessible areas of the building’s exterior and interior.

Prior to initiation of the building assessment, Aerostar conducted a review of historical facility records to determine if information was available regarding previous asbestos surveys, asbestos abatement, or major renovations. According to information provided by NAVSTA Newport, a previous asbestos survey was conducted in 1992 by H+GCL. Aerostar was provided with a copy of this report, which was used for informational purposes only. A memorandum of an asbestos

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 2 inspection, dated March 1995, was included with the previous asbestos survey report. No records of major renovations were found or provided to Aerostar during the historical research phase.

A total of 50 homogeneous areas (HAs) were identified in Building 447. Two HAs were not sampled due to the systems being energized and operational or being encased within doors and are assumed to contain asbestos until sampled, which includes gaskets and fire doors. A total of 162 samples were collected and submitted to EMSL Analytical, Inc. (EMSL) in Cinnaminson, New Jersey, for analysis by Polarized Light Microscopy (PLM). In accordance with the ASTM International Standard E2356-14, Non-friable Organically Bound (NOB) materials containing 1% or less asbestos by PLM were reanalyzed by Transmission Electron Microscopy (TEM) analysis to verify asbestos content. A total of 34 samples were reanalyzed by TEM analysis. A total of seven samples of skim coat were also analyzed by Environmental Protection Agency (EPA) Point Count (400 points) Method to further assess and quantify the asbestos content. Analytical results of the samples revealed that four HAs identified and sampled were found to contain greater than 1% asbestos by PLM or TEM, which includes Vinyl Floor Tile (VFT) mastics and caulk. Two HAs identified and sampled were found to contain less than 1% asbestos by PLM or TEM, which includes skim coat and expansion joint.

Removal and handling of ACMs should be conducted in accordance with the Occupational Safety and Health Administration’s (OSHA) Construction Standard for Asbestos 29 Code of Federal Regulations (CFR) 1926.1101 and the EPA’s Standard 40 CFR 61 Subpart M, and transportation of ACM should be conducted in accordance with the Department of Transportation (DOT) regulations outlined in 49 CFR 173.216. ACM must be disposed of at a facility permitted by the EPA and RIDH to accept asbestos.

Suspect ACMs encountered during renovation/demolition activities that are not identified in this survey should be assumed to contain asbestos or be sampled by a RIDH-licensed asbestos inspector and analyzed by an accredited laboratory.

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 3

2.0 INTRODUCTION

On January 16 and 17, and June 12, 2018; Aerostar conducted an ACM survey of Building 447, NGIS, located at NAVSTA Newport, Newport, Newport County, Rhode Island. The survey included all accessible areas throughout the building’s exterior and interior. The ACM survey was performed by RIDH-licensed Asbestos Inspectors. Copies of licenses are included in Appendix A.

2.1 Building Description

Building 447 is a four-story structure, including a basement. The 67,736-square foot building was constructed in 1969 and is currently used as a lodging facility. The building construction is on a basement foundation. Exterior finishes include brick and concrete, aluminum windows, and an Ethylene Propylene Diene Monomer (EPDM) membrane roof. Interior finishes include drywall, concrete, and concrete block walls; drywall, concrete and suspended ceilings; and wood, carpet, floor tile, ceramic tile, and concrete floors. The building is concrete frame construction insulated with fiberglass batting. Each unit contains an individual Heating, Ventilation, and Air Conditioning (HVAC) window system. Former central HVAC ductwork remains in the building and contains metal ducting. Pipe runs and elbows were insulated with fiberglass lagging.

2.2 Historical Research

Prior to initiation of the building assessment, Aerostar conducted a review of historical facility records to determine if information was available regarding previous asbestos surveys, asbestos abatement, or major renovations. According to information provided by NAVSTA Newport, a previous asbestos survey was conducted in 1992 by H+GCL. Aerostar was provided with a copy of this report, which was used for informational purposes only. A memorandum of an asbestos inspection, dated March 1995, was included with the previous asbestos survey report. No records of major renovations were found or provided to Aerostar during the historical research phase.

3.0 REGULATORY SUMMARY

3.1 Environmental Protection Agency

The EPA has published a list of hazardous air pollutants and promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. Since asbestos presents a significant risk to human health as a result of air emissions from one or more source categories, it is therefore considered a hazardous air pollutant. The Asbestos NESHAP Regulation (40 CFR 61, Subpart M) addresses milling, manufacturing and fabricating operations, demolition and renovation activities, waste disposal issues, active and inactive waste disposal sites and asbestos conversion processes.

Friable ACM is defined by the Asbestos NESHAP regulations as any material containing greater than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM, that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure (Sec. 61.141).

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 4

Non-friable ACM is any material containing greater than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM, that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure (Sec. 61.141).

The EPA also defines two categories of non-friable ACM: Category I and Category II non-friable

ACM.

• Category I non-friable ACM is any asbestos-containing packing, gasket, mastic, resilient floor covering or asphalt roofing product which contains greater than 1% asbestos as determined using PLM according to the method specified in Appendix E, Subpart E, 40 CFR Part 763 (Sec. 61.141).

• Category II non-friable ACM is any material, excluding Category I non-friable ACM, containing greater than 1% asbestos as determined using PLM according to the methods specified in Appendix E, Subpart E, 40 CFR Part 763 (Sec. 61.141), that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Regulated Asbestos-Containing Material (RACM) is: (a) friable ACM, (b) Category I non-friable ACM that has become friable, (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations.

Category I non-friable ACM must be inspected and tested for friability if it is in poor condition prior to demolition to determine whether or not it is subject to NESHAP. If the ACM is friable, it must be handled in accordance with NESHAP. Asbestos-containing packings, gaskets, resilient floor coverings and asphalt roofing materials must be removed prior to demolition only if they are in poor condition and are friable.

The NESHAP further requires that if a facility is demolished by intentional burning, all of the facility's ACM, including Category I and II non-friable ACM, must be removed prior to burning (Sec. 61.145(c)(10)).

If Category I or Category II non-friable ACM is to be sanded, ground, cut, or abraded, the material is considered RACM and the owner or operator must abide by the following (Sec. 61.145(c)(1)):

(i) Adequately wet the material during the sanding, grinding, cutting or abrading operations;

(ii) Comply with the requirements of 61.145(c)(3)(i) if wetting would unavoidably damage equipment or present a safety hazard; and

(iii) Handle asbestos material produced by the sanding, grinding, cutting, or abrading, as asbestos-containing waste material subject to the waste handling and collection provisions of Section 61.150.

Except for the following, Section 61.145(c) of the Asbestos NESHAP regulation requires that each owner or operator of a demolition or renovation activity involving RACM remove all such material from a facility being demolished or renovated before any activity begins that would break up, Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 5 dislodge, or similarly disturb the material or preclude access to the material for subsequent removal.

ACM need not be removed before demolition or renovation if it:

(i) Is a Category I non-friable ACM that has not become friable;

(ii) Is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition or renovation;

(iii) Was not accessible for testing and therefore was not discovered until after demolition or renovation began and, as a result of the demolition or renovation, cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestos-containing waste material and kept adequately wet at all times until disposed of; or

(iv) Is a Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition or renovation.

3.2 Occupational Safety and Health Administration

OSHA regulates asbestos exposure during all construction work including, but not limited to, the following:

• Demolition or salvage of structures where asbestos is present;

• Removal or encapsulation of materials containing asbestos;

• Construction, alteration, repair, maintenance, or renovation of structures, substrates, or portions thereof, that contain asbestos;

• Installation of products containing asbestos;

• Asbestos spill/emergency cleanup; and

• Transportation, disposal, storage, containment of and housekeeping activities involving asbestos or products containing asbestos, on the site or location at which construction activities are performed.

The OSHA Standard 29 CFR 1926.1101 requires the use of engineering controls, work practices, and personal protective equipment to reduce or eliminate employee exposure to asbestos. The OSHA standard does not apply to asbestos-containing asphalt roof coatings, cements and mastics.

3.3 State of Rhode Island

The RIDH Rules and Regulations for Asbestos Control, R23-24.5-ASB, cover all asbestos-related activities including, but not limited to, the following: Definitions, General Provisions, Asbestos Exposure Standard and Submission of Asbestos Abatement Plans, Asbestos Contractors, Abatement Plans and Owner Responsibilities, Certification of Training Courses, Competent Persons, Analytical Services and Consultants, Hazard Assessment Criteria, and NESHAP Requirements.

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 6

4.0 METHODS OF INVESTIGATION

Sampling protocols set forth by the EPA under 40 CFR 763.86 and ASTM E2356-14, Standard Practice for Comprehensive Building Asbestos Surveys, were generally followed during the inspection. The asbestos survey was performed by observing, touching, and sampling accessible suspect building materials throughout the interior and exterior of the building. The purpose of this survey was to locate and identify suspect ACMs, to quantify the material, and to separate it into unique areas for further assessment. The condition and location of representative suspect materials were defined throughout the building. Based on location, material type, and functional space use, the potential for disturbance by maintenance personnel and building occupants was evaluated and reported.

Bulk asbestos sampling procedures utilized for the collection of suspect ACMs first required the establishment of a homogeneous sampling area. A homogeneous sampling area is defined as an area of material of the same type (texture and color) which was applied during the same general time period. Each individual sampling area was then examined and representative samples of suspect materials were collected. The EPA has published guidelines and recommendations pertaining to surveying and sampling for friable ACMs. The guidelines were followed during the survey where appropriate. EPA publications and current regulations mainly address friable materials, such as surface finishes and structural fireproofing. Bulk samples were collected by a RIDH-certified Asbestos Inspector and analyzed by a laboratory that maintains accreditation by the National Institute of Science and Technology (NIST) through the National Voluntary Laboratory Accreditation Program (NVLAP). The samples were analyzed by PLM with dispersion staining according to EPA Method 600/R-93/116. The PLM test is an EPA-approved analytical method for asbestos identification. The test uses the unique optical properties of mineral forms in the samples to specifically identify the various asbestos types.

In accordance with EPA regulations, if friable materials which are analyzed by PLM contain less than 10% asbestos: a) the material may be assumed to contain greater than 1% asbestos and treated as an ACM, or b) the samples may be reanalyzed by the 400 Point Count Method to further characterize the concentration of asbestos fibers, as recommended by the EPA.

In accordance with the ASTM Standard E2356-14, NOB materials found to contain 1% or less asbestos by PLM were reanalyzed by TEM analysis to verify asbestos content.

Where distinct layers were present, bulk samples were collected to represent each individual layer of the suspect material. Mastic and/or other adhesive substances were included when possible. At the time of sample collection, the inspector noted material type, approximate amount, sampling locations, and condition of the materials.

Samples were labeled with a unique alphanumeric identification system (xxx-yy-zz). The first set of numbers (xxx) indicates the building number assigned by the facility. The second set of numbers (yy) indicates the homogeneous area designation assigned by the asbestos inspector. The third set of numbers (zz) is the individual sample identification number. Where distinct layers were separated, a letter (A, B, C) was assigned for each additional layer analyzed by the laboratory.

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 7

The surface area of the samples was adequately wetted prior to sample collection. No visible emissions were allowed. Following sample collection, sample locations were sealed to prevent subsequent fiber release. Samples were submitted to EMSL for analysis by PLM and TEM, as appropriate. A copy of the laboratory analytical results and appropriate Chain of Custody Records is included as Appendix B.

5.0 RESULTS

RIDH-licensed Asbestos Inspectors conducted an asbestos survey of Building 447 to identify the locations, quantities, and conditions of ACMs. The asbestos survey was performed throughout all areas of the building’s exterior and interior.

The following 50 HAs were identified in Building 447:

• Gypsum Wallboard

• Joint Compound

• Cove Base (5 types)

• Mastic Associated with Cove Base (6 types)

• Caulk Associated with Cove Base

• Carpet Mastic

• VFT (5 types)

• Mastic Associated with VFT (6 types)

• Floor Tile (2 types)

• Mastic Associated with Floor Tile

• Caulk (3 types)

• Skim Coat (3 types)

• Base Coat (2 types)

• Sink Mastic

• HVAC Duct Mastic

• Tread

• Mastic Associated with Tread

• Acoustic Ceiling Tiles

• Leveler

• Fiberglass TSI Wrap Mastic

• Concrete

• Expansion Joint

• EPDM Membrane Roof

• Foam

• Gaskets

• Fire Doors

Two HAs were not sampled due to the systems being energized and operational or being encased within doors and are assumed to contain asbestos until sampled. A total of 162 samples were collected and submitted to EMSL for analysis by PLM. NOB materials found to contain 1% or less asbestos by PLM analysis were reanalyzed by TEM analysis to verify asbestos content. A

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 8 total of 34 samples were reanalyzed by TEM analysis. A total of seven samples of skim coat were also analyzed by EPA Point Count (400 points) Method to further assess and quantify the asbestos content. Analytical results of the samples revealed that four HAs identified and sampled were found to contain greater than 1% asbestos by PLM or TEM. Two HAs identified and sampled were found to contain less than 1% asbestos by PLM or TEM.

A summary of materials found to contain asbestos is as follows:

Material Description

Homogeneous Area ID Location Approximate

Amount Asbestos Type %

NESHAP

Category

Black Mastic Associated with

12”x12” VFT - Gray 447-6A

Throughout Portions of the

Interior

4,500 Square Feet 4% Chrysotile

Non- Friable

Category I Black Mastic

Associated with VFT – Blue

447-9C Kitchens and

Bathrooms in all Units

7,500 Square Feet 4% Chrysotile

Non- Friable

Category I

Black Mastic Associated with VFT -

Blue 447-15C

Kitchen in Unit 108, and Kitchens and Bathrooms in

Units 202, 402, and

365 Square Feet 4% Chrysotile

Non- Friable

Category I

Door Caulk - Brown 447-22 Around Northern Exterior Entrance

45 Linear Feet 4% Chrysotile

Non- Friable

Category II

A summary of materials assumed to contain asbestos is as follows:

Homogeneous Area ID Location Approximate

Amount Asbestos Type %

NESHAP

Category

Gaskets 447-25 Throughout Mechanical Piping 56 Fittings Assumed

Non- Friable

Category I

Fire Doors 447-26 Throughout Building 146 Doors Assumed

Non- Friable

Category II

A summary of materials found to contain less than 1% asbestos is as follows:

Homogeneous Area ID Location Approximate

Amount Asbestos Type %

NESHAP

Category

Concrete Ceiling Skim Coat 447-13 Throughout Interior 56,000

Square Feet

<0.25% Chrysotile by Point Count

Expansion Joint - Beige 447-23 Seams Between the Brick Walls Near

Exterior Doors

135 Linear Feet

<0.1% Tremolite -

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 9

The results of the asbestos survey are detailed in Table 1. Homogeneous area sample locations are shown on Figures 1 through 6. The ACM locations are shown on Figures 7 through 12.

Inspector and laboratory credentials are provided in Appendix A. Copies of the laboratory analytical results and appropriate Chain of Custody Records are included in Appendix B.

Photographic Documentation is included as Appendix C.

6.0 LIMITATIONS

Aerostar has prepared this Final ACM Survey Report for CDM-AECOM Multimedia Joint Venture and NAVSTA Newport, hereafter referred to as the Clients. No ACM survey can eliminate all uncertainty. Professional judgment and interpretation are inherent in the process and uncertainty is inevitable. Even when sampling is executed with an appropriate site-specific standard of care, certain conditions present especially difficult detection problems. Such conditions may include, but are not limited to, physical limitations imposed by the location and accessibility of possible ACMs, and the limitations of assessment technologies. Only reasonably accessible areas were surveyed as part of this investigation. Aerostar is not responsible for possible ACMs that were inaccessible and/or not located, or any consequential damages as a result thereof.

Measurements and sampling data only represent the site conditions at the time of the data collection. Aerostar makes no legal representations whatsoever concerning any matter including, but not limited to, ownership of any property or the interpretation of any law. Aerostar further disclaims any obligations to update the report for events taking place after the time during which the assessment was conducted.

This report is not a comprehensive site characterization and should not be construed as such. The opinions presented in this report are based upon the findings derived from the samples collected.

The scope of work performed herein was limited to asbestos sample collection and laboratory analysis of only the samples collected at the time of inspection and identification of materials containing asbestos. Aerostar has endeavored to meet what it believes is the applicable standard of care, and, in doing so, is obliged to advise the Clients of the limitations. Aerostar believes that providing information about limitations is essential to help the Clients identify and thereby manage its risks. Through additional testing, these risks can be mitigated - but they cannot be eliminated.

Aerostar will, upon request, advise the Clients of the additional research opportunities available, their impact, and their cost.

As noted above, the ACM survey conducted at the referenced site and this report was prepared for the use solely by the Clients. This report shall not be relied upon by or transferred to any other party without the express written authorization of Aerostar; however, this report may be made available for informational and bidding purposes.

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 10

7.0 CONCLUSIONS AND RECOMMENDATIONS

The following summarizes the findings throughout the building and identifies classifications of material requiring special handling:

Building Friable ACM Non-friable Category I

ACM

Non-friable Category II

ACM

Material Containing <1%

Asbestos 447 – NGIS No Yes* Yes* Yes*

* Materials must be handled in accordance with 40 CFR 61 Subpart M and 29 CFR 1926.1101

A total of 50 HAs were identified in Building 447. Two HAs were not sampled due to the systems being energized and operational or being encased within doors and are assumed to contain asbestos until sampled, which includes gaskets and fire doors. A total of 162 samples were collected and submitted to EMSL for analysis by PLM. NOB materials found to contain 1% or less asbestos by PLM analysis were reanalyzed by TEM analysis to verify asbestos content. A total of 34 samples were reanalyzed by TEM analysis. A total of seven samples of skim coat were also analyzed by EPA Point Count (400 points) Method to further assess and quantify the asbestos content.

Analytical results of the samples revealed that four HAs identified and sampled were found to contain greater than 1% asbestos by PLM or TEM, which includes VFT mastics and caulk. Two HAs identified and sampled were found to contain less than 1% asbestos by PLM or TEM, which includes skim coat and expansion joint.

VFT mastics and gaskets are NESHAP Category I non-friable ACMs. NESHAP Category I non-friable ACMs are not required to be removed prior to demolition or renovation of the building, provided that wet-demolition practices are implemented and resulting debris from the building is properly transported to a landfill permitted for disposal of ACMs. If NESHAP Category I non-friable ACMs are in poor condition or become friable during demolition, the material must be treated as a RACM and be removed by a licensed asbestos abatement contractor and disposed of at a class one landfill prior to renovation, remodeling, or demolition of the building.

Caulk and fire doors are NESHAP Category II non-friable ACMs. NESHAP Category II non-friable ACMs should be removed by a licensed asbestos abatement contractor following OSHA Class II work activities and disposed of at a class one landfill prior to renovation, remodeling, or demolition of the building. If proper precautions and work practices are to be utilized, accompanied by wet demolition, to prevent Category II non-friable ACMs from becoming crumbled, pulverized, or reduced to powder during demolition activities, the material is not required to be removed prior to demolition.

Skim coat and expansion joints with less than 1% asbestos are not categorized by the NESHAP regulation; however, precautions must be taken when handling the material to prevent worker exposure to asbestos in accordance with OSHA standards.

Due to the presence of asbestos, OSHA’s Asbestos Standard for the Construction Industry (29 CFR 1926.1101) must be followed. The Rhode Island Department of Health Division of Occupational and Radiological Health should be notified in writing before a local building permit is granted for any building demolition or renovation which would disturb asbestos material.

Building 447, Navy Gateway Inns and Suites (NGIS), NAVSTA Newport, Newport, Newport County, Rhode Island September 28, 2018 Final ACM Survey Report, Aerostar Project Number M3010.1567.0001.17 Page 11

Transportation of ACM should be conducted in accordance with DOT regulations outlined in 49 CFR 173.216. ACM must be disposed of at a facility permitted by the EPA and RIDH to accept asbestos.

In accordance with the OSHA Asbestos Standard for the Construction Industry (29 CFR 1926.1101), demolition of a building with ACM left in place falls under the definition of removal of installed ACM. The removal of installed ACM is either Class I or Class II asbestos work, and all applicable requirements of this standard apply. Whether such demolition is Class I asbestos work or Class II asbestos work is determined by the type of ACM left in place. If any asbestos-containing thermal system insulation or surfacing material is left installed in the building, then the work being performed is Class I asbestos work. If the ACM left installed in the building does not include any thermal system insulation or surfacing material, then the work being performed is Class II asbestos work.

Suspect ACMs encountered during renovation/demolition activities that are not identified in this survey should be assumed to contain asbestos or be sampled by a RIDH-licensed asbestos inspector and analyzed by an accredited laboratory.

APPENDIX A

CERTIFICATIONS

APPENDIX B

LABORATORY ANALYTICAL RESULTS

APPENDIX C

PHOTOGRAPHIC DOCUMENTATION

TABLE 1

SUMMARY OF ASBESTOS SURVEY

Building 447 - Navy Gateway Inns and Suites (NGIS) Naval Station Newport

Newport, Newport County, Rhode Island

Maintenance Personnel

Building Occupants

447-1-1, 447-1-2, 447-1-3, 447-1-4, 447-1-5, 447-1-6, 447-1-7, 447-1-8, 447-1-9

Gypsum Wallboard Throughout Interior 220,000 SF 9 None Detected (ND) - Good - -

447-2-1, 447-2-2, 447-2-3, 447-2-4, 447-2-5, 447-2-6, 447-2-7, 447-2-8, 447-2-9

Joint Compound Throughout Interior 220,000 SF 9 ND - Good - -

447-3-1*, 447-3-2, 447-3-3 6" Cove Base - Brown

Portions of Main Entrance Lobby and Northeastern

Portion of First Floor Corridor

140 SF 3

ND

*Verified by

Transmission Electron Microscopy (TEM)

- Good - -

447-3-1A*, 447-3- 2A, 447-3-3A

Tan Mastic Associated with 6" Cove Base -

Brown

Portions of Main Entrance Lobby and Northeastern

Portion of First Floor Corridor

140 SF 3 ND

*Verified by TEM - Good - -

447-3-1B*, 447-3- 2B

Brown Mastic Associated with 6" Cove Base -

Brown

Portions of Main Entrance Lobby and Northeastern

Portion of First Floor Corridor

140 SF 2 ND

*Verified by TEM - Good - -

447-4-1*, 447-4-2, 447-4-3 Carpet Mastic - Tan Throughout Interior 40,000 SF 3 ND

*Verified by TEM - Good - -

447-5-1*, 447-5-2, 447-5-3 4" Cove Base - Gray Throughout Portions of the

Interior 780 SF 3 ND *Verified by TEM - Good - -

447-5-1A*, 447-5- 2A, 447-5-3A

Tan/Yellow Mastic Associated with 4" Cove

Base - Gray

Throughout Portions of the Interior 780 SF 3 ND

*Verified by TEM - Good - -

447-5-2B* Tan Caulk Associated with 4" Cove Base - Gray

Throughout Portions of the Interior 780 SF 1 ND

*Verified by TEM - Good - -

447-6-1*, 447-6-2, 447-6-3

12"x12" Vinyl Floor Tile (VFT) - Gray

Throughout Portions of the Interior 4,500 SF 3 ND

*Verified by TEM - Fair - -

447-6-1A, 447-6- 2A, 447-6-3A

Black Mastic Associated with 12"x12" VFT - Gray

Throughout Portions of the Interior 4,500 SF 3 4% Chrysotile Non-Friable Category

(NF Cat.) I Fair Low Low

447-6-1B*, 447-6- 2B, 447-6-3B

Yellow Mastic Associated with 12"x12" VFT - Gray

Throughout Portions of the Interior 4,500 SF 3 ND

*Verified by TEM - Fair - -

LocationMaterial DescriptionHomogeneous Area Sample ID

Potential for Disturbance Condition

National Emission Standards for Hazardous Air

Pollutants Category

% Asbestos Type Number of

Samples Collected

Approximate Amount

Square Feet (SF) Linear Feet (LF)

Building 447 - Navy Gateway Inns and Suites (NGIS) Naval Station Newport

Newport, Newport County, Rhode Island

Maintenance Personnel

Building Occupants

LocationMaterial DescriptionHomogeneous Area Sample ID

Potential for Disturbance Condition

National Emission Standards for Hazardous Air

Pollutants Category

% Asbestos Type Number of

Samples Collected

Approximate Amount

Square Feet (SF) Linear Feet (LF)

447-7-1*, 447-7-2, 447-7-3 Window Caulk - Beige Throughout Interior

Windows 3,600 LF 3 ND *Verified by TEM - Fair - -

447-8-1, 447-8-2, 447-8-3, 447-8-4, 447-8-5, 447-8-6, 447-8-7, 447-8-8, 447-8-9

Concrete Masonry Unit (CMU) Skim Coat

Throughout Corridors on the First Through Fourth

Floors 25,000 SF 9 ND - Good - -

447-8-2A CMU Base Coat Throughout Corridors on the First Through Fourth

Floors 25,000 SF 1 ND - Good - -

447-9-1*, 447-9-2, 447-9-3

12"x12" VFT - Gray Speckled

Kitchens and Bathrooms in all Units 7,500 SF 3 ND

*Verified by TEM - Good - -

447-9-1A*, 447-9- 2A, 447-9-3A

Yellow Mastic Associated with 12"x12" VFT - Gray

Speckled

Kitchens and Bathrooms in all Units 7,500 SF 3 ND

*Verified by TEM - Good - -

447-9-1B*, 447-9- 2B, 447-9-3B* VFT - Blue Kitchens and Bathrooms in all Units 7,500 SF 3 ND *Verified by TEM - Good - -

447-9-3C Black Mastic Associated with VFT - Blue

Kitchens and Bathrooms in all Units 7,500 SF 1 4% Chrysotile NF Cat. I Good Low Low

447-10-1*, 447-10- 2, 447-10-3 4" Cove Base - Beige

Kitchens and Bathrooms in the Southwestern Units on the First Through Fourth

Floors

315 SF 3 ND

*Verified by TEM - Good - -

447-10-1A*, 447-10- 2A, 447-10-3A

Tan/Yellow Mastic Associated with 4" Cove

Base - Beige

Kitchens and Bathrooms in the Southwestern Units on the First Through Fourth

Floors

315 SF 3 ND

*Verified by TEM - Good - -

447-11-1*, 447-11- 2, 447-11-3 Sink Mastic - White

Kitchens in all Units and Fourth Floor Kitchen adjacent to Lounge

320 SF 3 ND

*Verified by TEM - Good - -

447-12-1*, 447-12- 2, 447-12-3

Heating, Ventilation, and Air Conditioning

(HVAC) Duct Mastic - Gray

On Metal HVAC Ductwork in General Storage 1 4 SF 3 ND

*Verified by TEM - Fair - -

447-13-1, 447-13-2, 447-13-3, 447-13-4, 447-13-5, 447-13-6, 447-13-7, 447-13-8, 447-13-9

Concrete Ceiling Skim Coat Throughout Interior 56,000 SF 9 <0.25% Chrysotile by

Point Count - Fair Medium Low

Building 447 - Navy Gateway Inns and Suites (NGIS) Naval Station Newport

Newport, Newport County, Rhode Island

Maintenance Personnel

Building Occupants

LocationMaterial DescriptionHomogeneous Area Sample ID

Potential for Disturbance Condition

National Emission Standards for Hazardous Air

Pollutants Category

% Asbestos Type Number of

Samples Collected

Approximate Amount

Square Feet (SF) Linear Feet (LF)

447-13-2A Concrete Ceiling Base Coat Throughout Interior 56,000 SF 1 ND - Fair - -

447-14-1*, 447-14- 2, 447-14-3 Tread Mastic - Yellow Elevator 40 SF 3 ND

*Verified by TEM - Good - -

447-14-1A*, 447-14- 2A, 447-14-3A Tread - Red Elevator 40 SF 3 ND

*Verified by TEM - Good - -

447-14-1B*, 447-14- 2B, 447-14-3B Gray Floor Tile Elevator 40 SF 3 ND

*Verified by TEM - Good - -

447-14-1C*, 447-14- 2C, 447-14-3C Tan/White Floor Tile Elevator 40 SF 3 ND

*Verified by TEM - Good - -

447-14-1D*, 447-14- 2D, 447-14-3D

Yellow Mastic Associated with Tan/White Floor Tile Elevator 40 SF 3 ND

*Verified by TEM - Good - -

447-15-1*, 447-15- 2, 447-15-3

12"x12" VFT - Gray Mottled

Kitchen in Unit 108, and Kitchens and Bathrooms in

Units 202, 402, and 403

365 SF 3 ND

*Verified by TEM - Good - -

447-15-1A*, 447-15- 2A, 447-15-3A

Yellow Mastic Associated with 12"x12" VFT - Gray

Mottled

Kitchen in Unit 108, and Kitchens and Bathrooms in

Units 202, 402, and 403

365 SF 3 ND

*Verified by TEM - Good - -

447-15-1B*, 447-15- 2B, 447-15-3B VFT - Blue

Kitchen in Unit 108, and Kitchens and Bathrooms in

Units 202, 402, and 403

365 SF 3 ND

*Verified by TEM - Good - -

447-15-1C, 447-15- 2C, 447-15-3C

Black Mastic Associated with VFT - Blue

Kitchen in Unit 108, and Kitchens and Bathrooms in

Units 202, 402, and 403 365 SF 3 4% Chrysotile NF Cat. I Good Low Low

447-16-1, 447-16-2, 447-16-3

1'x1' Acoustic Ceiling Tile (ACT) - Fissures

First Floor Womens Restroom, General Storage

1A, and Fourth Floor Restrooms and Lounge

800 SF 3 ND - Fair - -

447-17-1*, 447-17- 2, 447-17-3 4" Cove Base - Black Storage 002 and Storage

003 40 SF 3 ND

*Verified by TEM - Good - -

447-17-1A*, 447-17- 2A, 447-17-3A

White Mastic Associated with 4" Cove Base - Black

Storage 002 and Storage

003 40 SF 3 ND

*Verified by TEM - Good - -

Building 447 - Navy Gateway Inns and Suites (NGIS) Naval Station Newport

Newport, Newport County, Rhode Island

Maintenance Personnel

Building Occupants

LocationMaterial DescriptionHomogeneous Area Sample ID

Potential for Disturbance Condition

National Emission Standards for Hazardous Air

Pollutants Category

% Asbestos Type Number of

Samples Collected

Approximate Amount

Square Feet (SF) Linear Feet (LF)

447-18-1*, 447-18- 2, 447-18-3

4" Cove Base - Light Gray

Kitchens and Bathrooms in the Northeastern Units on the First Through Fourth Floors and Fourth Floor

Kitchen adjacent to Lounge

420 SF 3 ND

*Verified by TEM - Good - -

447-18-1A*, 447-18- 2A, 447-18-3A

Tan Mastic Associated with 4" Cove Base - Light

Gray

Kitchens and Bathrooms in the Northeastern Units on the First Through Fourth Floors and Fourth Floor

Kitchen adjacent to Lounge

420 SF 3 ND

*Verified by TEM - Good - -

447-18-2B, 447-18- 3B Leveler

Kitchens and Bathrooms in the Northeastern Units on the First Through Fourth Floors and Fourth Floor

Kitchen adjacent to Lounge

420 SF 2 ND - Good - -

447-19-1*, 447-19- 2, 447-19-3

Fiberglass Thermal System Insulation (TSI)

Wrap Mastic - White

Throughout Fiberglass Insulated Piping in the Basement Mechanical

Rooms

250 SF 3 ND

*Verified by TEM - Fair - -

447-20-1, 447-20-2, 447-20-3, 447-20-4, 447-20-5 Concrete Skim Coat

Northwestern Exterior Entrance and Basement

Exterior Ceiling 2,400 SF 5 ND - Good - -

447-20-1A, 447-20- 2A, 447-20-3A, 447- 20-4A, 447-20-5A

Concrete Northwestern Exterior

Entrance and Basement Exterior Ceiling

2,400 SF 5 ND - Good - -

447-21-1*, 447-21- 2, 447-21-3 Window Caulk - Beige Throughout Exterior

Windows 3,600 LF 3 ND *Verified by TEM - Fair - -

447-22-1, 447-22-2, 447-22-3 Door Caulk - Brown Around Northern Exterior

Entrance 45 LF 3 4% Chrysotile NF Cat. II Fair Low Low

447-23-1*, 447-23- 2, 447-23-3 Expansion Joint - Beige Seams Between the Brick

Walls Near Exterior Doors 135 LF 3 <0.1% Tremolite *Verified by TEM - Fair Low Low

447-24-1*, 447-24- 2, 447-24-3

Ethylene Propylene Diene Monomer (EPDM)

Membrane Roof Throughout Roof 15,300 SF 3 ND

*Verified by TEM - Good - -

447-24-1A, 447-24- 2A, 447-24-3A Foam Throughout Roof 15,300 SF 3 ND - Good - -

Building 447 - Navy Gateway Inns and Suites (NGIS) Naval Station Newport

Newport, Newport County, Rhode Island

Maintenance Personnel

Building Occupants

LocationMaterial DescriptionHomogeneous Area Sample ID

Potential for Disturbance Condition

National Emission Standards for Hazardous Air

Pollutants Category

% Asbestos Type Number of

Samples Collected

Approximate Amount

Square Feet (SF) Linear Feet (LF)

447-25 Gaskets Throughout Mechanical Piping 56 Fittings 0 Assumed NF Cat. I Good Medium Low

447-26 Fire Doors Throughout Building 146 Doors 0 Assumed NF Cat. II Good Medium Low

APPENDIX A

CERTIFICATIONS

SSttaattee ooff RRhhooddee IIssllaanndd aanndd PPrroovviiddeennccee PPllaannttaattiioonnss

DDEEPPAARRTTMMEENNTT OOFF HHEEAALLTTHH

HHEEAALLTTHHYY EENNVVIIRROONNMMEENNTT TTEEAAMM –– AASSBBEESSTTOOSS PPRROOGGRRAAMM

CCEERRTTIIFFIICCAATTIIOONN

Pursuant to the Asbestos Abatement Act, Chapter 24.5 of Title 23 of the General Laws entitled "Health and Safety" as amended, and the Rules and Regulations for Asbestos Control, this Certificate is hereby issued as designated below. This Certificate is subject to all applicable rules, regulations, orders and notices of the Department of Health now or hereafter in effect and to any conditions specified below.

Certificate Holder: DYLAN HALES

Address: AEROSTAR

3749 N CAUSWAY BLVD STE A

METAIRIE LA 70002

Certification Number: AAC-1032 Type of Certification: Asbestos Inspector

Expiration Date: 11/08/2018

Except as specifically provided otherwise in this Certificate, Certificate holders shall conduct their program in accordance with statements, procedures and representations contained in the documents, including any enclosures, listed below. The Rhode Island Rules and Regulations for Asbestos Control shall govern unless the statements, representations and procedures in the Certificate Holder's application and correspondence are more restrictive than the regulations.

Raquel Barrera Sr. Community Program Liaison Worker Healthy Homes and Environment

SSttaattee ooff RRhhooddee IIssllaanndd aanndd PPrroovviiddeennccee PPllaannttaattiioonnss

DDEEPPAARRTTMMEENNTT OOFF HHEEAALLTTHH

HHEEAALLTTHHYY EENNVVIIRROONNMMEENNTT TTEEAAMM –– AASSBBEESSTTOOSS PPRROOGGRRAAMM

CCEERRTTIIFFIICCAATTIIOONN

Pursuant to the Asbestos Abatement Act, Chapter 24.5 of Title 23 of the General Laws entitled "Health and Safety" as amended, and the Rules and Regulations for Asbestos Control, this Certificate is hereby issued as designated below. This Certificate is subject to all applicable rules, regulations, orders and notices of the Department of Health now or hereafter in effect and to any conditions specified below.

Certificate Holder: CHRISTOPHER SWEETMAN

Address: AEROSTAR SES LLC

11181 STJOHN INDUSTRIAL PKY N

JACKSONVILLE FL 32246

Certification Number: AAC-1033 Type of Certification: Asbestos Inspector

Expiration Date: 11/08/2018

Except as specifically provided otherwise in this Certificate, Certificate holders shall conduct their program in accordance with statements, procedures and representations contained in the documents, including any enclosures, listed below. The Rhode Island Rules and Regulations for Asbestos Control shall govern unless the statements, representations and procedures in the Certificate Holder's application and correspondence are more restrictive than the regulations.

Raquel Barrera Sr. Community Program Liaison Worker Healthy Homes and Environment

APPENDIX C

PHOTOGRAPHIC DOCUMENTATION

EMSL Analytical, Inc.

200 Route 130 North Cinnaminson, NJ 08077

Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

AERO54

041802129EMSL Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: M3010.1567.0001.17 / BLDG 447

Phone: (904) 565-2820

Fax: (904) 565-2830

Collected: 1/16/2018

Received: 1/22/2018

Analyzed: 2/21/2018

Matt Minard

Aerostar SES LLC

11181 St. Johns Industrial Parkway North

Jacksonville, FL 32246

Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0001447-1-1

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 12% 88%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0002447-1-2

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 12% 88%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0003447-1-3

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 12% 88%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0004447-1-4

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 12% 88%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0005447-1-5

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 17% 83%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0006447-1-6

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0007447-1-7

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 14% 86%PLM White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/16/2018 08:34AM Page 1 of 21

Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

AERO54

041802129EMSL Order ID:

Customer ID:

Customer PO:

Project ID:

Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0008447-1-8

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 12% 88%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0009447-1-9

Gypsum Wallboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 20% 80%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0010447-2-1

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0011447-2-2

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0012447-2-3

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0013447-2-4

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0014447-2-5

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0015447-2-6

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/16/2018 08:34AM Page 2 of 21

Phone/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

AERO54

041802129EMSL Order ID:

Customer ID:

Customer PO:

Project ID:

Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0016447-2-7

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0017447-2-8

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/30/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0018447-2-9

Joint Compound

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/30/2018 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 041802129-0019447-3-1

6" Cove Base - Brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

1/29/2018 0% 100%PLM Brown None Detected

2/06/2018 0.0% 100%TEM…