ITN_GRM260685_Development__Affordable_Housing__NW_7thAvenue_Subdivision_Section_4__Exhibit_E__Conceptual_Subdivision_Plans_3.pdf
PDF 4 MB Posted
- Solicitation number
- ITN# GRM/260685
- Issued by
- Marion County, Orlando City, Florida
About this file
This is a set of conceptual subdivision plans and construction documents prepared by Kimley-Horn and Associates, Inc. for the City of Ocala, Florida, detailing the NW 7th Avenue Subdivision development project. The project encompasses 1.48 acres of property in Section 18, Township 15 South, Range 22 East, comprising 13 parcels identified by Marion County parcel numbers. The proposed development calls for reducing the existing 12 residential home sites to 7 dwelling units, with construction specifications including 18-foot asphalt roadways, concrete sidewalks with maximum 5% running slope, and ADA-compliant accessibility features. The site is zoned R-2 (Residential) with Future Land Use designated as Neighborhood, located in FEMA Flood Zone X (minimal flooding risk). The plans include utilities infrastructure for potable water and wastewater service provided by the City of Ocala, with a total potable water demand of 2,100 gallons per day and sewer demand of 1,925 gallons per day. All construction must comply with City of Ocala Land Development Code and the City's Standard Specifications for Water and Sewer Construction, with mandatory pre-construction meetings required with the City's Development Coordinator at (352) 629-8421 prior to any site work commencement.
The traffic impact analysis, utilizing Institute of Transportation Engineers data, projects 90 daily trips from the 7-unit development with 10 AM peak-hour trips (2 entering, 8 exiting) and 8 PM peak-hour trips (5 entering, 3 exiting). The project includes installation of 273 linear feet of 8-inch SDR 26 PVC sanitary sewer line at 0.45% slope, 4-inch and 8-inch water main extensions with gate valves and concrete thrust blocks, and utility details complying with FDEP water/sewer separation requirements. A solid waste impact fee of $265 per buildable lot is due at final plat issuance. The City of Ocala will provide perpetual maintenance for drainage systems and common areas. Key utility contacts include City of Ocala Fiber Technicians (352-401-3999), Water and Sewer Department (352-351-6775), Ocala Electric Utility (352-351-6650), CenturyLink Dispatch (855-742-6062), and TECO Peoples Gas (813-228-4025). The contractor is responsible for all erosion and sediment control measures, as-built documentation prepared by a Florida-licensed surveyor, bacteriological testing, and obtaining necessary permits from regulatory agencies. The survey was performed by JCH Consulting Group, Inc. on August 13, 2019, with topographic data referenced to NAVD 88 datum.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N W
7T H
AV
EN
U E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
FO
R
TH
E
C
IT
Y O
F O
C
AL
A C
O
VE
R
SH
EE
T
C-01
CITY OF OCALA, FLORIDA
MAY 2020
NW 7TH AVENUE SUBDIVISION
CONCEPTUAL SUBDIVISION PLANS
FOR
SECTION 18, TOWNSHIP 15 SOUTH, RANGE 22 EAST
DRAWING INDEX
SHEET - TITLE
C-01 - COVER SHEET
C-02 - GENERAL NOTES
C-03 - SITE PLAN
C-04 - GRADING PLAN
C-05 - UTILITY PLAN
C-06 - CONSTRUCTION DETAILS
C-07 - UTILITY DETAILS
1 OF 2 TOPOGRAPHIC SURVEY (JCH CONSULTING GROUP, INC.)
2 OF 2 TOPOGRAPHIC SURVEY (JCH CONSULTING GROUP, INC.)
PROJECT
LOCATION
NORTH
Project Location
LOCATION MAP
FIBER:
CITY OF OCALA TELECOMMUNICATIONS
FIBER TECHNICIANS
(352) 401-3999
TELEPHONE:
CENTURY LINK
DISPATCH
(855) 742-6062
WATER & SEWER:
CITY OF OCALA
VICKI SCHOOLEY
(352) 351-6775
GAS:
TECO PEOPLES GAS
PHILLIS BRIDGES
(813) 228-4025
UTILITY PROVIDERS
SURVEYOR:
JCH CONSULTING GROUP, INC.
426 SW 15TH ST
OCALA, FLORIDA 34471
(352) 405-1482
OWNER/APPLICANT:
CITY OF OCALA
110 SE WATULA AVE
OCALA, FL 34471
(352) 629-2489
CIVIL ENGINEERING CONSULTANT:
KIMLEY-HORN AND ASSOCIATES, INC.
101 E SILVER SPRINGS BLVD, SUITE 400
OCALA, FLORIDA 34470
(352) 438-3000
PROJECT OWNER AND CONSULTANTS
GENERAL NOTES
PARCEL ID:
2840-017-001, 2840-017-002, 2840-017-003, 2840-017-004, 2840-017-005, 2840-017-006, 2840-017-007, 2840-017-101, 2840-017-102, 2840-017-202, 28509-000-00, 28511-000-00, AND 28512-000-00
PROJECT AREA:
1.48 AC
EXISTING ZONING:
R-2
FUTURE LAND USE:
NEIGHBORHOOD
EASEMENTS:
ALL EASEMENTS ARE DESIGNATED ON THE PLANS.
TREE LOCATION:
THE PROPOSED PROJECT AND ITS ORIENTATION TO EXISTING TREES WERE PROVIDED BY JCH CONSULTING GROUP INC.
FEMA DESIGNATION:
THE PROJECT AREA LIES IN FLOOD ZONE 'X' - AN AREA OF MINIMAL FLOODING, ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP. COMMUNITY-PANEL NUMBER 12083C0509E, EFFECTIVE DATE APRIL 19, 2017.
WATER:
POTABLE WATER SERVICE WILL BE PROVIDED BY CITY OF OCALA
SEWER:
WASTEWATER SERVICE WILL BE PROVIDED BY CITY OF OCALA
DRAINAGE:
SEE NOTE, THIS SHEET.
SOLID WASTE:
A SOLID WASTE IMPACT FEE IS DUE AND PAYABLE FOR EACH RESIDENTIAL UNIT AT THE TIME OF FINAL PLAT. THE COST IS $265.00
PER BUILDABLE LOT.
CONTOURS:
TOPOGRAPHIC INFORMATION PROVIDED BY A SURVEY FROM JCH CONSULTING GROUP INC., DATED AUGUST 13, 2019.
ELEVATIONS ARE IN NAVD 88 DATUM.
LOCAL BENCH MARK:
REFER TO TOPOGRAPHIC SURVEY (JCH CONSULTING GROUP, INC. DATED AUGUST 13, 2019)
MAINTENANCE:
THE CITY OF OCALA SHALL PROVIDE PERPETUAL MAINTENANCE FOR THE DRAINAGE SYSTEMS AND COMMON AREAS OF THE
DEVELOPMENT.
PERMITS:
CITY OF OCALA SITE CONCEPTUAL SUBDIVISION PLAN NO. SUB19-0014
TRAFFIC IMPACT STATEMENT:
TRIP GENERATION RATES WERE OBTAINED FROM THE INSTITUTE OF TRANSPORTATION ENGINEERS (ITE) TRIP GENERATION 10TH EDITION FOR LAND USE CODE 210, AS OUTLINED BELOW. BASED ON A DEVELOPMENT PROGRAM OF 7 DWELLING UNITS, THE SITE WILL GENERATE 90 DAILY, 10 AM PEAK HOUR (2 ENTERING, 8 EXITING), AND 8 PM PEAK HOUR (5 ENTERING, 3 EXITING) PROJECT
TRIPS.
DAILY TRIP GENERATION FORMULA: LN(T) =0.92LN(X) +2.71 (X IS THE NUMBER OF DWELLING UNITS) AM PEAK HOUR TRIP GENERATION FORMULA: T = 0.71*(X)+4.80; (X IS NUMBER OF DWELLING UNITS); (25% IN/75% OUT) PM PEAK HOUR TRIP GENERATION FORMULA: LN(T) = 0.96*LN(X)+0.2; (X IS NUMBER OF DWELLING UNITS); (63% IN/37% OUT)
CONSTRUCTION:
1. ALL CONSTRUCTION COVERED BY THESE PLANS SHALL COMPLY WITH THE MATERIAL REQUIREMENTS AND QUALITY CONTROL
STANDARDS CONTAINED IN THE CITY OF OCALA LAND DEVELOPMENT CODE AND THE CITY OF OCALA WATER AND SEWER
CONSTRUCTION MANUAL.
2. PRIOR TO THE START OF CONSTRUCTION, THE PROJECT ENGINEER SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE DEVELOPMENT COORDINATOR, (352) 629-8421. MEETING WILL TAKE PLACE AT THE GROWTH MANAGEMENT DEPARTMENT WITH ENGINEER, CONTRACTOR AND STAFF. NO SITE WORK SHALL COMMENCE PRIOR TO THIS MEETING TAKING PLACE.
3. ALL MATERIALS, MACHINERY, AND VEHICLES SHALL BE STORED ON-SITE IN AN ORDERLY FASHION.
4. ALL STORMWATER MANAGEMENT SYSTEMS SHALL BE COMPLETED PRIOR TO THE CONSTRUCTION OF IMPERVIOUS AREAS.
ELECTRIC:
CITY OF OCALA ELECTRIC
OEU LOCATOR
(352) 351-6650
DRAINAGE NOTE:
THIS PROJECT WILL REDUCE THE NUMBER OF EXISTING
RESIDENTIAL HOME SITES (12 EXISTING, 7 PROPOSED).
THEREFORE, NO STORMWATER DESIGN OR IMPROVEMENTS
ARE PROPOSED OR REQUIRED.
W
7T H
AV
EN
U E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
FO
R
TH
E
C
IT
Y O
F O
C
AL
A G
EN
ER
AL
N
O
TE
S
C-02
SIGNAGE AND PAVEMENT MARKING NOTES:
1. ALL SIGNS MUST MEET THE CITY OF OCALA'S STANDARDS FOR SIGN FACES IN REFLECTIVITY.
2. ALL FINAL PAVEMENT MARKINGS WITHIN THE STATE AND PUBLIC RIGHT-OF-WAYS SHALL BE THERMOPLASTIC.
3. ALL STOP SIGNS (R1-1) SHOULD BE 30" AND FABRICATED USING 3M DIAMOND GRADE VIP REFLECTIVE SHEETING.
4. STOP AND STREET NAME SIGNS SHALL BE MOUNTED ONTO THE SAME POLE.
5. STOP LINES SHALL BE TWENTY-FOUR INCHES (24") WIDE AND LANE WIDTH.
6. ALL SIGNS SHALL BE SIZED IN ACCORDANCE WITH MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)
STANDARDS.
7. STREET NAME SIGN SPECIFICATIONS WILL BE PER CITY OF OCALA STANDARDS.
PAVING AND DRAINAGE NOTES CONTINUED:
9. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PERMITTED CONSTRUCTION DOCUMENTS. ANY DEVIATION FROM THE APPROVED CONSTRUCTION DOCUMENTS SHALL BE THE SOLE RESPONSIBILITY OF THE ORGANIZATION AND/OR ENTITY RESPONSIBLE FOR THE INSTALLATION TO UPDATE/REPLACE ANY DEFICIENT MATERIAL/EQUIPMENT NECESSARY TO BRING THE FINAL PRODUCT TO THE STANDARDS OF THE PERMITTED CONSTRUCTION DOCUMENTS.
10. THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF SEDIMENT AND EROSION CONTROL
MEASURES DURING CONSTRUCTION. REFER TO THE STORMWATER POLLUTION PREVENTION PLAN.
11. COMPACTION DENSITIES FOR ALL ROADWAY CROSSINGS ARE TO BE TAKEN IN ONE-FOOT (1') LIFTS.
12. LIMEROCK BERING RATIOS FOR SUBGRADE AT FORTY (40) AND LIMEROCK OR ALTERNATIVE BASE COURSE AT ONE
HUNDRED (100). THERE WILL BE NO UNDER TOLERANCE.
13. ALL MATERIAL USED FOR BACKFILL SHALL BE A3 FREE DRAINING SAND.
14. THERE ARE TO BE NO OPEN TRENCHES AT THE DAY'S END.
15. THE CONTRACTOR SHALL ADHERE TO ALL NOTES PROVIDED IN THESE CONSTRUCTION DRAWINGS.
16. ALL CONSTRUCTION LINES & GRADES SHALL BE ESTABLISHED AND MAINTAINED BY THE CONTRACTOR.
17. CONTRACTOR WILL CLEAR, GRUB AND DISPOSE OF ALL DEBRIS AND SURFACE ORGANICS IN ALL EASEMENTS, ROAD
RIGHT-OF-WAYS AND DETENTION AREAS. DISPOSAL SHALL BE INCLUDED IN THE CONTRACT.
18. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PREVENTION OF DOWNSTREAM TURBIDITY/ SILTATION THROUGH THE USE OF HAY BALES, SCREENS, SILTATION BASINS, AND/OR ANY OTHER SUITABLE MEANS REQUIRED TO MEET FLORIDA STREAM STANDARDS. SEED AND MULCH ALL DISTURBED AREAS, SOD AS REQUIRED TO CONTROL EROSION THROUGH
FINAL INSPECTION AND TO PRODUCE A UNIFORM STAND OF GRASS THROUGHOUT.
19. CONTRACTOR SHALL BE RESPONSIBLE FOR BRICKING UP CURB INLETS TO FINISHED GRADE AND FURNISHING AND
MAINTAINING ALL HARDWARE.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTING CURB TRANSITIONS TO FINISH GRADE.
21. UNDERDRAINS SHALL BE INSTALLED, BY THE CONTRACTOR, IN ALL CASES WHERE THE GROUNDWATER TABLE IS CLOSER THAN 24 INCHES BELOW THE PROPOSED CENTERLINE GRADE OF ANY ROAD. CONTACT ENGINEER IF ISSUE IS
ENCOUNTERED.
22. ALL DISTURBED AREAS SHALL RECEIVE GRASS SEED, FERTILIZER, AND MULCH. AREAS SHALL HAVE BEEN FILLED AND GRADED AS NECESSARY TO PROVIDE PROPER DRAINAGE. SLOPES STEEPER THAN 4:1 SHALL BE PINNED OR PEGGED
SOD.
23. FILTER WRAP SHALL BE USED ON ALL DRAINAGE JOINTS AS REQUIRED BY FDOT SPECIFICATIONS.
24. A 2' STRIP OF SOD IS REQUIRED AROUND ALL DITCH BOTTOM INLETS.
25. ALL POND SIDE SLOPES SHALL BE STABILIZED WITH ESTABLISHED GRASS AT TIME OF FINAL INSPECTION.
26. HANDICAP RAMPS SHALL BE INSTALLED WHEREVER THE SIDEWALK MEETS THE CURB, AND SHALL COMPLY WITH ALL
ADA REQUIREMENTS.
DEMOLITION NOTES:
1. CODES
ALL CODES REGULATING DEMOLITION WORK SHALL BE COMPLIED BY THE CONTRACTOR. THE CONTRACTOR SHALL PUT
UP AND MAINTAIN SUCH BARRIERS AND WARNING LIGHTS, AS MAY BE NECESSARY OR REQUIRED BY CODE, TO PROTECT AND PREVENT UNAUTHORIZED PERSONNEL FROM ENTERING THE DEMOLITION WORK AREA. ALL DEMOLITION OPERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) INSOFAR AS THEY APPLY TO DEMOLITION WORK TO BE PERFORMED UNDER THIS CONTRACT.
2. PROTECTION OF BUILDINGS & EQUIPMENT
TEMPORARY PROTECTIVE DEVICES, AS REQUIRED SHALL BE INSTALLED ADJACENT TO THE DEMOLITION WORK FOR
PROTECTION PERSONNEL, EXISTING ADJACENT BUILDINGS, STRUCTURES AND EQUIPMENT AGAINST DUST, FALLING OR FLYING DEBRIS. ANY DAMAGE TO EXISTING STRUCTURES, FACILITIES AND/OR EQUIPMENT RESULTING FROM
DEMOLITION WORK SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE OWNER.
3. DISPOSAL OF EXISTING EQUIPMENT & DEBRIS
ALL DEBRIS AND EXISTING MATERIALS AND EQUIPMENT SHALL BE HAULED AWAY AND DISPOSED OF BY THE
CONTRACTOR. THE CONTRACTOR SHALL MAKE HIS OWN ARRANGEMENTS FOR OBTAINING DISPOSAL AREAS. THE CONTRACTOR SHALL TAKE EVERY PRECAUTION TO PREVENT SPILLAGE OF MATERIALS BEING HAULED IN PUBLIC STREETS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY CLEAN UP ANY SPILLAGE WHICH MAY
ACCIDENTALLY OCCUR.
4. CLEAN-UP
THE CONTRACTOR SHALL MAINTAIN AN ORDER OF NEATNESS AND GOOD HOUSEKEEPING. TOOLS, SCAFFOLDING AND
OTHER DEMOLITION EQUIPMENT MUST AT ALL TIMES BE KEPT IN A NEAT AND ORDERLY ARRANGEMENT. AT THE CONCLUSION OF THE DEMOLITION OPERATIONS, THE ENTIRE WORK AREA SHALL BE LEFT IN A CLEAN CONDITION AS
REQUIRED FOR SUBSEQUENT NEW WORK.
GENERAL NOTES:
1. ALL CONSTRUCTION COVERED BY THESE PLANS SHALL COMPLY WITH THE MATERIAL REQUIREMENTS AND QUALITY CONTROL STANDARDS CONTAINED IN THE OCALA LAND DEVELOPMENT CODE AND CURRENT CITY OF OCALA "WATER
AND SEWER CONSTRUCTION MANUAL" FOR UTILITIES.
2. ELEVATIONS BASED ON SURVEY PROVIDED BY JCH CONSULTING GROUP, INC., DATED AUGUST 13, 2019.
3. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING THE SITE PRIOR TO CONSTRUCTION.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL/DISPOSAL OF ANY UNSUITABLE MATERIAL FROM THEIR OPERATION, FURNISHING AND COMPACTING SUITABLE REPLACEMENT BACKFILL MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REGULATIONS.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS REQUIRED FOR THE PROJECT.
6. THE LOCATION OF ALL UTILITIES SHOWN ON THE DRAWINGS ARE FROM INFORMATION PROVIDED BY FIELD
OBSERVATIONS.
7. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM, IN THE FIELD, THE LOCATIONS AND ELEVATIONS
SHOWN PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
8. THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION AND BUILDING PLACEMENT WITH ALL OTHER UTILITIES
CONSTRUCTION.
9. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PRODUCE, SUBMIT AND OBTAIN APPROVAL OF REPRODUCIBLE
"AS-BUILT" DRAWINGS FROM JURISDICTIONAL AGENCIES AS MAY BE REQUIRED.
10. "AS-BUILT" INFORMATION SHALL BE MAINTAINED BY THE CONTRACTOR. CONTRACTOR SHALL EMPLOY THE SERVICES OF A SURVEYOR REGISTERED IN THE STATE OF FLORIDA TO DETERMINE ALL "AS-BUILT" INFORMATION. UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL PROVIDE UP TO SIX COPIES AND THE CAD FILE OF AS-BUILT DRAWINGS TO THE ENGINEER. ALL UNDERGROUND FITTINGS MUST BE REFERENCED TO AT LEAST TWO VISIBLE REFERENCE POINTS ON THE AS-BUILT DRAWINGS. AS-BUILT PLANS ARE REQUIRED PRIOR TO ISSUANCE OF THE
CERTIFICATE OF OCCUPANCY.
11. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE EROSION AND TURBIDITY CONTROLS DURING AND FOLLOWING CONSTRUCTION UNTIL ALL DISTURBED AREAS HAVE BEEN STABILIZED TO AVOID ADVERSE
ENVIRONMENTAL IMPACTS TO OFF-SITE PROPERTY AND DRAINAGE SYSTEMS.
12. ALL SEDIMENT AND EROSION CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH
CONSTRUCTION POLLUTION PREVENTION PLAN INCLUDED HEREIN.
13. THE CONTRACTOR SHALL PROVIDE A TEMPORARY WATER SERVICE OR WATER TRUCK FOR WASH-DOWN OF VEHICLES
LEAVING THE PROJECT SITE IF NECESSARY.
14. ALL UNDERGROUND UTILITIES TO BE INSTALLED SHALL BE IN ACCORDANCE WITH THE CITY OF OCALA UTILITIES
SPECIFICATIONS AND THE APPROVED SITE PLANS.
15. THE CONTRACTOR(S) SHALL NOTIFY ALL APPLICABLE UTILITIES COMPANIES, THE ENGINEER OF RECORD, AND THE PROPERTY OWNER 48 HOURS PRIOR TO INITIATING ANY EXCAVATION ACTIVITIES, OR AS SPECIFIED BY THE UTILITIES
COMPANIES AND THE PERMITS OBTAINED FOR THE WORK.
16. THE ENGINEER OF RECORD SHALL BE GIVEN FORTY EIGHT HOURS (48-HR) NOTICE OF ALL MEETINGS AND OR TESTING
MEASURES RELATED TO SAID PROJECT.
17. CONSTRUCTION WARNING SIGNS ARE TO BE MOUNTED AND ERECTED BEFORE CONSTRUCTION CAN COMMENCE.
THESE AND ALL TRAFFIC CONTROL DEVICES SHALL FOLLOW THE STANDARDS SET FORTH BY THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AS WELL AS FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) STANDARD
INDEX.
18. THE CONTRACTOR IS RESPONSIBLE FOR CLEARLY IDENTIFYING THE AREA OF CONSTRUCTION AND SAFELY ROUTING ALL VEHICULAR AND PEDESTRIAN TRAFFIC AROUND THE CONSTRUCTION AREA. THE CONSTRUCTION AREA SHALL BE
CLEARLY MARKED AT ALL TIMES.
19. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SODDED ACCORDING TO LOCAL REGULATIONS.
20. THE CONTRACTOR(S) SHALL LOCATE, VERIFY, AND IDENTIFY ALL EXISTING UNDERGROUND UTILITIES SHOWN OR NOT
SHOWN ON THE PLANS PRIOR TO ANY EXCAVATING ACTIVITIES.
21. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO EXCAVATION AND TAKE ALL MEASURES NECESSARY TO PROTECT UTILITIES DURING CONSTRUCTION. SHOULD ANY UTILITY LINE OR COMPONENT BECOME DAMAGED OR REQUIRE RELOCATION THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE RESPONSIBLE UTILITY
COMPANY, THE ENGINEER OF RECORD, AND THE CITY/COUNTY.
22. THE CONTRACTOR SHALL PROTECT EXISTING UTILITIES, SURVEY MARKERS, MONUMENTS, ETC. DURING CONSTRUCTION. THE CONTRACTOR SHALL RESTORE/REPLACE ANY DAMAGE DONE BY CONSTRUCTION ACTIVITIES.
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES CAUSED BY HIS OPERATIONS.
24. THERE SHALL BE A MINIMUM THREE (3) DAYS NOTICE GIVEN FOR SCHEDULING THE FINAL INSPECTION.
25. A PERMIT MUST BE OBTAINED FROM THE CITY OF OCALA PRIOR TO COMMENCEMENT OF ANY WORK WITHIN THE CITY
RIGHT OF WAY.
WATER/SEWER SEPARATION REQUIREMENTS (FDEP) CONTINUED:
(C) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST (6) SIX FEET, AND PREFERABLY (10) TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY- OR PRESSURE-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610 F.A.C. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND GRAVITY-TYPE SANITARY SEWERS SHALL BE REDUCED TO (3) THREE FEET WHERE THE BOTTOM OF THE WATER MAIN IS LAID AT LEAST (6)
SIX INCHES ABOVE THE TOP OF THE SEWER.
(D) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST (10) TEN FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED "ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM" AS DEFINED IN SECTION 381.0065(2). F.S. AND
RULE 64E-6.002. F.A.C.
(2) VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR
STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES:
(A) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED GRAVITY- OR VACUUM-TYPE SANITARY SEWER OR STORM SEWER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST (6) SIX INCHES, AND PREFERABLY 12 INCHES ABOVE OR AT LEAST 12 INCHES BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE.
(B) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE.
(C) AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST (3) THREE FEET FROM ALL JOINTS IN VACUUM-TYPE SANITARY SEWERS, STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C., AND AT LEAST (6) SIX FEET FROM ALL JOINTS IN GRAVITY- OR PRESSURE-TYPE SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED
WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.
(3) SEPARATION BETWEEN WATER MAINS AND SANITARY OR STORM SEWER MANHOLES:
(A) NO WATER MAIN SHALL PASS THROUGH, OR COME INTO CONTACT WITH, ANY PART OF A SANITARY MANHOLE OR A
STORM SEWER MANHOLE.
(4) SEPARATION BETWEEN FIRE HYDRANT DRAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. NEW OR RELOCATED FIRE HYDRANTS WITH UNDERGROUND DRAINS SHALL BE LOCATED SO THAT THE DRAINS ARE AT LEAST THREE FEET FROM ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AT LEAST THREE FEET, AND PREFERABLY TEN FEET, FROM ANY EXISTING OR PROPOSED VACUUM-TYPE SANITARY SEWER; AT LEAST SIX FEET, AND PREFERABLY TEN FEET, FROM ANY EXISTING OR PROPOSED GRAVITY- OR PRESSURE-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AND AT LEAST TEN FEET FROM ANY EXISTING OR PROPOSED “ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM” AS DEFINED IN SECTION 381.0065(2), F.S., AND RULE 64E-6.002, F.A.C.
EXCEPTIONS/MITIGATION:
WHERE IT IS NOT TECHNICALLY FEASIBLE OR ECONOMICALLY SENSIBLE TO COMPLY WITH THE REQUIREMENTS IN ITEMS (1) THROUGH (4) ABOVE, THE CONTRACTOR SHALL STOP WORK AND IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, WHO WILL DETERMINE THE APPROPRIATE SOLUTION. IF A SUBSTANTIAL DEVIATION FROM THE PERMITTED DESIGN IS REQUIRED, A REQUEST FOR PERMIT REVISION WILL BE SUBMITTED TO THE DEPARTMENT OF
ENVIRONMENTAL PROTECTION (FDEP) FOR APPROVAL PRIOR TO CONSTRUCTION.
SANITARY SEWER SYSTEM NOTES:
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS OR WATER
AND SEWER CONSTRUCTION.
2. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES AND CONNECTION POINTS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ALL DISCREPANCIES WITH THESE PLANS SHALL BE REPORTED TO THE
ENGINEER IMMEDIATELY FOR RESOLUTION.
3. ALL EQUIPMENT AND MATERIALS SHALL COMPLY WITH THE CITY OF OCALA STANDARDS FOR WATER AND SEWER CONSTRUCTION, SECTION 499. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIAL FOR APPROVAL BY THE ENGINEER AND THE CITY OF OCALA UTILITIES DEPARTMENT PRIOR TO THE PURCHASE OR
INSTALLATION OF ANY EQUIPMENT OR MATERIAL.
4. GRAVITY SANITARY SEWER LINE SHALL CONFORM TO ASTM D-3034, SDR-26, COLOR GREEN AND CLEARLY MARKED AND
CODED.
5. SANITARY SEWER FORCE MAIN SHALL BE PVC, C-900, DR 18, 200 PSI PRESSURE PIPE CONFORMING TO ASTM D1784 AND D1785 SDR 18. SANITARY FORCE MAIN SHALL BE COLOR CODED GREEN AND CLEARLY MARKED. PVC FORCE MAINS SHALL HAVE LOCATING WIRES ON THE TOP AND BOTTOM OF THE FORCE MAIN IN ACCORDANCE WITH THE CITY OF OCALA SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. MEGALUGS ARE NOT PERMITTED ON PVC
FORCE MAINS. (NOTE DOES NOT PERTAIN TO THIS SITE)
6. CONCRETE THRUST BLOCKS SHALL BE USED ON ALL PVC PRESSURE PIPING.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING OF ALL SANITARY PIPE AND APPURTENANCES IN ACCORDANCE WITH THE CITY OF OCALA SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. TESTING SHALL BE PERFORMED
IN THE PRESENCE OF THE CITY ENGINEER OR A DESIGNATED REPRESENTATIVE.
8. CONTRACTOR SHALL SUBMIT TO THE ENGINEER AND CITY OF OCALA WATER RESOURCES DEPARTMENT ALL VIDEO
LOGS AND DEFLECTION TEST RESULTS FOR REVIEW AND APPROVAL.
9. CONTRACTOR SHALL INSURE THAT THE MINIMUM HORIZONTAL AND VERTICAL CLEARANCE IS MAINTAINED TO ALL OTHER WET UTILITIES IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (FDEP)
REQUIREMENTS.
10. ALL MANHOLE COVERS IN TRAFFIC AREAS SHALL BE HINGED AND LOCKABLE PER CITY OF OCALA SPECIFICATIONS FOR
WATER AND SEWER CONSTRUCTION.
POTABLE WATER SYSTEM NOTES CONTINUED:
10. ALL PVC PRESSURE PIPING SHALL USE CONCRETE THRUST BLOCKING AT ALL BENDS AND TERMINATIONS. THRUST BLOCK SIZING SHALL BE IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. PVC WATER MAINS SHALL HAVE TWO LOCATING WIRES INSTALLED (ON THE TOP AND BOTTOM) ALONG THE
PIPE.
11. ALL WATER MAIN FITTINGS SHALL BE DIP FOR PVC AND DIP WATER MAINS 3" AND ABOVE AND USED AT LOCATIONS INDICATED ON THE PLANS, UNLESS OTHERWISE APPROVED BY THE ENGINEER. PIPE DEFLECTIONS AT JOINTS SHALL NOT EXCEED THE
MANUFACTURER'S RECOMMENDED DEFLECTION.
12. ALL UNDERGROUND VALVES SHALL BE INSTALLED WITH AN ADJUSTABLE CAST IRON VALVE BOX WITH THE TOP SET TO FINAL GRADE IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. VALVE BOXES IN TRAFFIC AREAS SHALL BE LOCKABLE OR NON-POP LIDS IN ACCORDANCE WITH STANDARD DETAIL 478-4.1A OF THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. VALVES DEEPER THAN 5' SHALL HAVE VALVE
NUT EXTENSIONS WHICH SHALL BE WELDED AS ONE PIECE.
13. ALL HYDRANTS, GATE VALVES AND TAPPING GATE VALVES SHALL HAVE STAINLESS STEEL STEMS.
14. FIRE HYDRANTS ARE TO BE FACTORY PAINTED RED. (VERIFY GPM FOR CAP COLORS)
15. FIRE HYDRANTS ARE TO BE INSTALLED WITH THE STEAMER CONNECTION FACING THE ROADWAY.
16. SITE CONTRACTOR SHALL PROVIDE ALL CHAINS, LOCKS AND KEYS FOR DDCVA'S AS REQUIRED BY THE LOCAL FIRE DEPARTMENT.
17. ALL NEW AND RELOCATED WATER MAINS SHALL BE PRESSURE AND LEAK TESTED IN ACCORDANCE WITH AWWA STANDARD C600, LATEST EDITION. PRESSURE TESTING SHALL BE IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION, SECTION 481.5.2. PRESSURE TESTING SHALL BE AT A PRESSURE OF AT LEAST 150 PSI FOR A MINIMUM DURATION OF 2 HOURS. ALLOWABLE LEAKAGE SHALL BE WITHIN THE PARAMETERS OF THE CITY OF OCALA
STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION, SECTION 481.5.2.6.
18. ALL NEW AND RELOCATED WATER MAINS SHALL BE DISINFECTED IN ACCORDANCE WITH AWWA STANDARD C651 AND RULE 62-555.345, F.A.C.
19. ALL PIPE AND PIPE FITTINGS FOR NEW AND RELOCATED WATER SERVICES SHALL COMPLY WITH THE LATEST FDEP AND AWWA STANDARDS FOR LEAD CONTENT. ALL SOLDERS AND FLUX FOR NEW AND RELOCATED WATER SERVICES SHALL COMPLY WITH
THE LATEST FDEP AND AWWA STANDARDS FOR LEAD CONTENT.
20. CONTRACTOR'S SURVEYOR SHALL PROVIDE AS-BUILT DRAWINGS, INCLUDING ALL UNDERGROUND UTILITIES, IN CAD FORMAT TO THE ENGINEER USING THE DRAFTING STANDARDS REQUIRED BY THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER
AND SEWER CONSTRUCTION.
21. SITE CONTRACTOR SHALL SUPPLY AND INSTALL ALL BACKFLOWS, METERS AND METER BOXES NOT PROVIDED BY THE LOCAL
WATER PROVIDER.
PROCEDURES:
22. CONTRACTOR SHALL ARRANGE A PRE-CONSTRUCTION CONFERENCE WITH THE CITY OF OCALA UTILITIES
DEPARTMENT AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
23. ALL WATER AND SEWER TAPS SHALL BE SCHEDULED AT LEAST 48 HOURS IN ADVANCE WITH THE CITY OF OCALA UTILITIES
DEPARTMENT.
24. ALL ON-SITE WATER AND SEWER CONSTRUCTION REQUIRES A PLUMBING PERMIT WITH A SCHEDULED INSPECTION BY THE CITY OF OCALA UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ARRANGING ALL
INSPECTIONS.
25. CONNECTION TO EXISTING POTABLE WATER SYSTEMS SHALL NOT BE ALLOWED UNTIL ALL PROPOSED WATER LINES HAVE BEEN PRESSURE TESTED, DISINFECTED, CLEARED FOR SERVICE AND ACCEPTED FOR MAINTENANCE BY THE CITY OF OCALA UTILITIES
DEPARTMENT AND FDEP.
26. JUMPER CONNECTIONS MAY BE USED TO FILL OR FLUSH WATER MAINS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION, STANDARD DETAIL 488-5.1. A PERMIT MUST BE OBTAINED FROM THE CITY OF OCALA WATER RESOURCES DEPARTMENT PRIOR TO THE CONSTRUCTION OF THE
TEMPORARY JUMPER CONNECTION.
27. ALL COMMERCIAL BUILDING PERMITS AND METERS SHALL BE PROCESSED THROUGH THE CITY OF OCALA UTILITIES, WATER AND SEWER CUSTOMER SERVICE DEPARTMENT AND SHALL BE ACCOMPANIED BY A SET OF APPROVED SET OF CIVIL DESIGN PLANS.
28. THE CONTRACTOR SHALL OBTAIN A LETTER OF RELEASE TO PLACE THE CONSTRUCTION INTO SERVICE FROM THE CITY OF OCALA UTILITIES DEPARTMENT. THE CONTRACTOR SHALL PRESENT A SET OF AS-BUILT PLANS WITH THE LOCATIONS OF THE BACTERIOLOGICAL SAMPLING INDICATED IN RED OR PINK. THE SAMPLE NUMBERS SHALL CORRESPOND TO THOSE ON THE
BACTERIOLOGICAL SAMPLE LAB SHEETS.
29. SITE CONTRACTOR IS RESPONSIBLE FOR ALL BACTERIOLOGICAL TESTING AND CHLORINATION.
CITY OF OCALA REGULATORY STATEMENTS:
1. CONTRACTOR SHALL PROVIDE THE CITY OF OCALA ENGINEERING DEPARTMENT WITH A COPY OF ALL PERMITS
OBTAINED FROM REGULATORY AGENCIES AND WATER MANAGEMENT DISTRICTS.
2. CONTRACTOR SHALL PROVIDE CERTIFIED AS-BUILT PLANS PRIOR TO THE CLEARANCE OF THE UTILITY LINES.
3. CONTRACTOR SHALL INSTALL LOCATOR WIRE ON ALL UNDERGROUND UTILITIES CONSTRUCTED OF NON-CONDUCTIVE
MATERIALS.
4. CONTRACTOR SHALL CONTACT THE CITY OF OCALA WATER AND SEWER DEPARTMENT 72 HOURS IN ADVANCE OF
MAKING ANY CONNECTIONS TO THE CITY WATER OR SEWER SYSTEM.
5. ALL EXISTING OR PROPOSED WATER, SEWER, OR REUSE APPURTENANCES AFFECTED BY THE DEVELOPMENT OF THIS
SITE ARE TO BE RAISED TO THE FINAL GRADE PRIOR TO ISSUANCE OF THE C.O.
6. ASBUILTS, MEETING THE CITY OF OCALA WATER AND SEWER CONSTRUCTION MANUAL REQUIREMENTS ARE TO BE
SUPPLIED TO THE CITY PRIOR TO ISSUANCE OF THE C.O.
GEOTECHNICAL NOTES:
1. IF CLAYEY SOILS ARE ENCOUNTERED DURING CONSTRUCTION THE CONTRACTOR SHALL COORDINATE WITH THE PROJECT ENGINEER FOR RECOMMENDATIONS ON HOW TO PROCEED WITH THE PLACEMENT AND USE OF THESE SOILS.
2. BECAUSE OF THE LOCATION OF THE PROJECT, IT CAN BE EXPECTED THAT LIMESTONE WILL BE ENCOUNTERED DURING CONSTRUCTION. LIMESTONE DEPOSITS IN THIS PART OF MARION COUNTY CAN RANGE FROM SCATTERED SOFT DEPOSITS TO LARGE ROCK BOULDERS. IT IS ANTICIPATED THAT MOST OF THE LIMESTONE ENCOUNTERED DURING CONSTRUCTION CAN BE EXCAVATED USING NORMAL EARTH MOVING EQUIPMENT. HOWEVER, HARDER DEPOSITS MAY REQUIRE ROCK BREAKERS OR RIPPING EQUIPMENT. ANY LIMESTONE REMOVAL SHALL BE INCLUDED IN THE
CONTRACTOR'S BID FOR EARTH MOVING ACTIVITIES.
3. SHOULD ANY SINKHOLE ACTIVITY BE OBSERVED DURING CONSTRUCTION THE CONTRACTOR SHALL CONTACT THE
PROJECT ENGINEER IMMEDIATELY FOR GUIDANCE ON REPAIRING THE SINKHOLE.
ELECTRICAL NOTES:
1. CUSTOMER MUST SUBMIT THE CITY OF OCALA ELECTRIC UTILITY (OEU) COMMERCIAL LOAD DATA SHEET AND THE OEU GENERAL INFORMATION SHEET TO THE ZONING DEPARTMENT PRIOR TO ANY SITE PERMITS BEING ISSUED.
DATA SHEETS MUST BE APPROVED BY OEU ENGINEERING PRIOR TO ANY SITE PERMITS BEING ISSUED. MATERIAL LEAD TIMES MAY CAUSE A DELAY IN OBTAINING SERVICE, IF LOAD DATA IS NOT SUBMITTED AS SOON AS POSSIBLE.
2. CUSTOMER MUST CONTACT THE CITY OF OCALA ELECTRIC UTILITY ENGINEERING DIVISION AT (352) 351-6620 AT LEAST SIX (6) WEEKS PRIOR TO THE START OF CONSTRUCTION TO DISCUSS PERMANENT SERVICE REQUIREMENTS, TEMPORARY CONSTRUCTION POWER, TRANSFORMER LOCATION, AND METER LOCATION. REFERENCE CITY PROJECT
#TBD.
3. TREES CANNOT BE PLANTED AROUND, OVER, OR UNDER ANY EXISTING OR PROPOSED POWER LINES. THIS INCLUDES ANY LINES DESIGNED AFTER FINAL SITE PLAN APPROVAL. NO NEW SHADE TREES WILL BE PERMITTED WITHIN 30 FEET OF OVERHEAD POWER LINES. ALL PLANS WILL REQUIRE A (20) FOOT WIDE UTILITY EASEMENT AND TREE TRIMMING
EASEMENTS FOR EXISTING AND PROPOSED OVERHEAD ELECTRIC LINES.
4. FOR ALL UNDERGROUND ELECTRIC POWER LINES ON PRIVATE PROPERTY, A TEN (10) FOOT ELECTRIC DISTRIBUTION EASEMENT WILL BE REQUIRED. FOR OVERHEAD CONSTRUCTION, A TWENTY (20) FOOT EASEMENT WILL BE REQUIRED. ALSO, FOR ANY OVERHEAD POWER LINES, BOTH EXISTING AND PROPOSED, A TEN (10) FOOT
TREE-TRIMMING EASEMENT WILL BE REQUIRED (SEC.70-585 AND SEC. 70-602).
5. UNDERGROUND ELECTRICAL SERVICE WILL BE AT THE CUSTOMER'S EXPENSE (SEC. 70-584 AND SEC. 70-603).
6. ALL ELECTRIC UTILITY FACILITIES SHALL BE INCLUDED ON THE SITE PLAN PRIOR TO SITE PLAN APPROVAL (INCLUDE
YELLOW AND BLACK FACILITY I.D. NUMBER).
7. METER LOCATION WILL BE DESIGNATED BY OCALA ELECTRIC UTILITY (SEC. 70-587). HOWEVER, DESIRED LOCATION
MAY BE NOTED ON SITE PLAN.
8. THE REQUESTED SERVICE VOLTAGE IS 120/208 VOLT, 3 PHASE. REQUESTED SERVICE VOLTAGE IS NOT GUARANTEED TO BE SUPPLIED, HOWEVER, OEU WILL TRY TO ACCOMMODATE THE REQUEST WHEN POSSIBLE (SEC. 70-585 AND SEC.
70-587).
9. STREETLIGHTS, IF REQUIRED, WILL BE ADDED AT A ONE TIME CHARGE TO THE CUSTOMER. ESTIMATED COST WILL BE PROVIDED AS PART OF THE ACTUAL ELECTRICAL SERVICE DESIGN (SEC. 70-621). STREETLIGHT DESIGN FOR ALL
PRIVATE ROADS MUST BE SHOWN ON SITE PLANS AND APPROVED BY OEU.
10. CONSTRUCTION FOR TEMPORARY SERVICE LOCATION TO BE DETERMINED BY OCALA ELECTRIC UTILITY.
11. THE FINAL APPROVED SITE PLAN IS TO BE EMAILED TO USING THE ABOVE MENTIONED OEU SITE PLAN REFERENCE NUMBER. ELECTRIC ENGINEERING WORK WILL NOT BEGIN UNTIL APPROVED ELECTRONIC SITE PLAN HAS BEEN
SUBMITTED.
12. ADDITIONAL REQUIREMENTS ARE CONTAINED IN CHAPTER 70, ARTICLE VI AND ARTICLE VII OF THE OCALA CODE OF
ORDINANCES.
POTABLE WATER SYSTEM NOTES:
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR THE PROPER NOTIFICATION OF INSPECTING
AUTHORITIES BEFORE AND DURING CONSTRUCTION.
2. ALL WATER AND SEWER CONSTRUCTION SHALL BE ACCOMPLISHED BY AN UNDERGROUND UTILITY CONTRACTOR WITH
A CLASS 5 LICENSE UNDER THE PROVISIONS OF CHAPTER 489, FLORIDA STATUTES.
3. ALL MATERIALS AND CONSTRUCTION PROCEDURES AND TECHNIQUES SHALL BE IN ACCORDANCE WITH THE CITY OF
OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION.
WATER & SEWER SYSTEM CONSTRUCTION AND MAINTENANCE NOTE:
THE UNDERGROUND WATER AND SEWER SYSTEMS CONSTRUCTED ON THIS SITE SHALL BE CONSTRUCTED, TESTED AND INSPECTED
IN ACCORDANCE WITH THE FOLLOWING:
SEWER SYSTEM:
CITY OF OCALA “STANDARD SPECIFICATIONS FOR CONSTRUCTION OF STREETS, STORMWATER, TRAFFIC, WATER AND SEWER
INFRASTRUCTURE”.
CONSTRUCT ALL GRAVITY SEWERS 8” AND ABOVE INCLUDING MANHOLES AND ALL SEWER SERVICES 6” OR LESS TO THE FIRST CLEANOUT UPSTREAM FROM THE 8” OR ABOVE SEWER MAIN TO CITY STANDARDS. INSPECTION WILL BE PERFORMED
BY THE CITY WATER & SEWER DEPARTMENT.
STATE OF FLORIDA “STANDARD PLUMBING CODE”.
ALL GRAVITY SEWER SERVICES 6” OR LESS FROM THE FIRST CLEANOUT UPSTREAM FROM THE 8” OR ABOVE GRAVITY SEWER MAIN WILL BE CONSTRUCTED TO FLORIDA STANDARD PLUMBING CODE REQUIREMENTS. INSPECTION AND TESTING WILL BE PERFORMED BY THE CITY BUILDING DEPARTMENT. THESE FACILITIES WILL BE MAINTAINED BY THE DEVELOPMENT.
WATER SYSTEM:
CITY OF OCALA “STANDARD SPECIFICATIONS FOR CONSTRUCTION OF STREETS, STORMWATER, TRAFFIC, WATER AND SEWER
INFRASTRUCTURE”.
CONSTRUCT ALL POTABLE WATER MAINS AND SERVICES, UP TO THE POINT OF METERING, TO CITY STANDARDS. INSPECTION
WILL BE PERFORMED BY THE CITY WATER & SEWER DEPARTMENT.
ALL FIRE MAINS AND HYDRANTS, FROM THE CITY WATER MAIN TO WITHIN FIVE FEET (5') OF THE BUILDING, SHALL BE CONSTRUCTED TO CITY STANDARDS OR NFPA 24 AS REQUIRED. INSPECTION AND TESTING WILL BE PERFORMED BY THE CITY WATER & SEWER DEPARTMENT. CITY OF OCALA WILL MAINTAIN THESE FACILITIES UP TO DDC LOCATIONS.
STATE OF FLORIDA “STANDARD PLUMBING CODE”.
ALL WATER SERVICES DOWNSTREAM FROM THE POINT OF METERING SHALL BE CONSTRUCTED TO FLORIDA STANDARD PLUMBING CODE REQUIREMENTS. INSPECTION AND TESTING WILL BE PERFORMED BY THE CITY BUILDING DEPARTMENT.
THESE FACILITIES WILL BE MAINTAINED BY THE DEVELOPMENT.
REUSE SYSTEM:
CITY OF OCALA “STANDARD SPECIFICATIONS FOR CONSTRUCTION OF STREETS, STORMWATER, TRAFFIC, WATER AND SEWER
INFRASTRUCTURE”.
CONSTRUCT ALL REUSE MAINS AND SERVICES, UP TO THE POINT OF METERING, TO CITY STANDARDS. INSPECTION WILL BE
PERFORMED BY THE CITY WATER & SEWER DEPARTMENT.
STATE OF FLORIDA “STANDARD PLUMBING CODE”.
ALL REUSE SERVICES DOWNSTREAM FROM THE POINT OF METERING SHALL BE CONSTRUCTED TO FLORIDA STANDARD PLUMBING CODE REQUIREMENTS. INSPECTION AND TESTING WILL BE PERFORMED BY THE CITY BUILDING DEPARTMENT.
THESE FACILITIES WILL BE MAINTAINED BY THE DEVELOPMENT.
PRE-CONSTRUCTION MEETING REQUIRED:
PRIOR TO ANY UNDERGROUND WATER, SEWER, OR REUSE CONSTRUCTION ON THIS SITE THE CONTRACTOR SHALL SET UP AN ON-SITE MEETING WITH THE CITY OF OCALA PROJECT INSPECTORS (352) 401-6935 OR (352) 351-6712 TO DISCUSS SHOP
DRAWINGS, INSTALLATION, INSPECTION, TESTING AND AS-BUILT REQUIREMENTS.
PAVING AND DRAINAGE NOTES:
1. ALL GRADING, PLACEMENT OF FILL, AND COMPACTION SHALL BE IN ACCORDANCE WITH CITY OF OCALA STANDARD SPECIFICATIONS AND THE FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) STANDARD SPECIFICATIONS FOR ROAD
AND BRIDGE CONSTRUCTION, LATEST EDITION AND ALL APPLICABLE ADA SPECIFICATIONS.
2. THE CONTRACTOR SHALL CONSTRUCT ALL DRAINAGE STRUCTURES TO THE DESIGN ELEVATIONS SHOWN AND IN
COMPLIANCE WITH TYPICAL CONSTRUCTION DETAILS.
3. ALL PIPE LENGTHS SHOWN HEREIN ARE APPROXIMATE LENGTHS FROM CENTER TO CENTER OF THE RELATED
STRUCTURES.
4. ALL PIPE LENGTHS ARE SCALED AND MAY REQUIRE SLIGHT FIELD ADJUSTMENTS TO FIT CONDITIONS. ALL PIPE
CROSSINGS SHALL BE COMPACTED TO 95% MAX. DENSITY AT 1' LIFTS.
5. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF THE PAVING AND DRAINAGE FACILITIES WITH ALL
OTHER CONSTRUCTION.
6. ALL PIPE JOINTS SHALL BE PROPERLY FITTED AND SEALED PER PRODUCT MANUFACTURERS SPECIFICATIONS.
7. THE CONTRACTOR SHALL COORDINATE ALL NOTIFICATIONS AND UTILITY LOCATION EFFORTS WITH THE UTILITY
OWNERS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
8. THE CONTRACTOR SHALL SUBMIT SEVEN (7) SETS OF SHOP DRAWINGS OF ALL STRUCTURES, EQUIPMENT, MATERIAL SPECIFICATIONS TO THE CONSTRUCTION MANAGER AND ENGINEER OF RECORD FOR REVIEW PRIOR TO THE
PURCHASE AND/OR INSTALLATION OF ANY STRUCTURES, EQUIPMENT, AND/OR MATERIAL.
WATER/SEWER SEPARATION REQUIREMENTS (FDEP):
62-555.314 LOCATION OF PUBLIC WATER SYSTEM MAINS: FOR THE PURPOSE OF THIS SECTION, THE PHRASE "WATER MAINS" SHALL MEAN MAINS, INCLUDING TREATMENT PLANT PROCESS PIPING, CONVEYING EITHER RAW, PARTIALLY TREATED, OR FINISHED DRINKING WATER; FIRE HYDRANT LEADS; AND SERVICE LINES THAT ARE UNDER THE CONTROL OF A PUBLIC
WATER SYSTEM AND THAT HAVE AN INSIDE DIAMETER OF THREE (3") INCHES OR GREATER.
(1) HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL
SYSTEMS:
(A) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST (3) THREE FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER
REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.
(B) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST (3) THREE FEET, AND PREFERABLY (10) TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE
OUTSIDE OF ANY EXISTING OR PROPOSED VACUUM-TYPE SANITARY SEWER.
POTABLE WATER SYSTEM NOTES CONTINUED:
1. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIAL FOR APPROVAL BY THE ENGINEER AND THE CITY OF OCALA UTILITIES DEPARTMENT PRIOR TO THE PURCHASE OR INSTALLATION OF ANY
EQUIPMENT OR MATERIAL.
2. TWO INCH (2”) TO TWELVE INCH (12”) WATER MAINS SHALL BE POLYVINYL CHLORIDE (PVC) OR DUCTILE IRON PIPE (DIP) BASED ON PRESSURE. WATER MAIN SIZES LARGER THAN 12” SHALL BE DUCTILE IRON PIPE (DIP). ALL PVC PIPE SHALL BE POTABLE WATER BLUE, HAVE IDENTIFYING TAPE AND LOCATING WIRE ON TOP AND BOTTOM. PVC PIPE SHALL MEET
THE REQUIREMENTS OF ANSI/AWWA C-900, DR14 AND DR18.
3. EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN SHOWN, BASED ON THE BEST INFORMATION AVAILABLE, WITHOUT EXPLORATORY EXCAVATIONS. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ANY AND ALL DISCREPANCIES WITH THE PLANS SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
4. THE VERTICAL LOCATIONS OF ALL EXISTING UTILITIES SHOWN ON THE PLAN AND PROFILE SHEETS HAVE BEEN ASSUMED. THE CONTRACTOR SHALL EXERCISE CAUTION DURING EXCAVATION NEAR EXISTING UTILITIES SHOWN ON THE PLANS AND NOTIFY THE ENGINEER IF THE LOCATION DIFFERS FROM THAT SHOWN ON THE PLANS BEFORE
CONTINUING WITH CONSTRUCTION.
5. SHOULD ANY CONDITIONS VARY FROM THOSE SHOWN ON THESE PLANS, THE CONTRACTOR SHALL IMMEDIATELY
NOTIFY THE ENGINEER FOR RESOLUTION PRIOR TO CONTINUING CONSTRUCTION.
6. UNSUITABLE SOIL MATERIALS UNDER WATER AND SEWER MAINS SHALL BE REMOVED AND REPLACED WITH SELECT BACKFILL IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER
CONSTRUCTION.
7. ALL ROCK AND UNSUITABLE SIZED STONES (AS DESCRIBED IN THE APPLICABLE AWWA AND THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION AND/OR THE PIPE MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES) FOUND IN THE TRENCHES FOR NEW AND RELOCATED WATER MAIN PIPE SHALL BE REMOVED TO A DEPTH OF AT LEAST SIX (6) INCHES BELOW THE BOTTOM OF THE PIPE. AN APPROVED BACKFILL MATERIAL SHALL BE PROVIDED AND SHAPED TO PROVIDE A CONTINUOUS AND UNIFORM BEDDING. THE BEDDING MATERIAL SHALL BE COMPACTED IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS
FOR WATER AND SEWER CONSTRUCTION, BASED ON ITS LOCATION.
8. COMPACTION OF PIPE TRENCHES SHALL BE IN ACCORDANCE WITH THE CITY OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER CONSTRUCTION. COMPACTION SHALL BE 95% OF AASHTO T-180 IN NON-TRAFFIC AREAS AND
98% OF AASHTO T-180 IN TRAFFIC AREAS.
9. WATER MAINS SHALL HAVE A MINIMUM OF 48” COVER FROM FINISHED GRADE.
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
SSMH #3486
SSMH #3367 SSMH #3366 SSMH #3365
8" C
LA
Y
6" CLAY
C L A
Y
8" CLAY
8" CLAY
8" CLAY
LIMEROCK/SLAG
PARCEL NO. 2840-017-007
PARCEL NO. 2840-017-006
PARCEL NO.
2840-017-002
PARCEL NO.
2840-017-202
PARCEL NO.
2840-017-102
PARCEL NO.
28511-000-00
PARCEL NO. 2840-017-003
B L O C K 1 7
N.
W
. 7
TH
A
VE
NU
E
(S
IG
N)
N.
W
. 8
TH
A
VE
NU
E
(S
IG
N)
PARCEL NO.
2840-017-004
N.W. 5TH ST. (SIGN)
PARCEL NO.
2840-017-005
PARCEL NO.
2840-017-001
PARCEL NO.
2840-017-101
PORTION OF
PARCEL NO.
28512-000-00
PARCEL NO.
28509-000-00
CSX RAILROAD
N.W. 6TH STREET (SIGN)
18' ASPHALT
' A
S P
H A
LT
' A
S P
H A
LT
18' ASPHALT
\A1;35.3'
\A1;36.5'
\A1 ;14
.8'
\A 1;4
0.0
\A 1;2
5.0
NO PARCEL NUMBER
PARCEL NO.
28507-000-00
PARCEL NO.
28505-000-00
B L O C K 2 0
PARCEL NO. 2840-020-001
PARCEL NO. 2840-020-201
PARCEL NO. 2840-020-101
PARCEL NO. 2840-020-104
PARCEL NO. 2840-020-004
PARCEL NO. 2840-020-204
\pxqc;NORTHERLY RIGHT OF WAY OF CSX RAILROAD
\pxqc;SOUTHERLY RIGHT OF WAY OF CSX RAILROAD
C
C
\pxqc;TREE DRIPLINE
\pxqc;TREE DRIPLINE
\pxqc;TREE DRIPLINE
2 3
PARK
N
0°
'5 8"
E
.8 8'
N 0°
'5
8" E
.9
9'
11,515.75
8,087.76 S.F.
7,425.37 S.F.
8,007.91 S.F.
7,155.10 S.F.
7,576.62 S.F.
N 0°
'5
8" E
.8
1'
7,439.18 S.F.
7,344.12 S.F.
S87°58'26"W 74.24'
S0 °0
7'
"E
.9 3'
S0 °1
1'
"W
.9 9'
S87°58'26"W 80.06'
S0 °1
1'
"W
.8 8'
S87°58'26"W 72.29'
N89°48'02"W 92.77'
N89°48'02"W 87.82'
S0 °1
1'
"W
.0 0'
N89°48'02"W 5.00'
S86°29'05"E 78.41'
N 0°
'5
8" E
.0
0'
N89°48'02"W 92.82' S0
°1 1'
"W
2.
S0 °1
1'
"W
.5 4'
S86°29'05"E 77.08'
N89°48'02"W 88.21' N89°48'02"W
5.00'
N 0°
'5
8" E
.0
0'
S0 °0
7'
"E
.0 0'
S0 °0
7'
"E
.0 6'
N 0°
'5
8" E
.4
8'
N89°48'02"W 70.00'
S86°29'05"E 70.12'
N 0°
'5
8" E
6.
C1
C2
C3
C4
N 0°
'5
8" E
.0
2'
HC
HC
HC
HC
ZONING: R-2
ZONING: R-2 ZONING: R-2
ZONING: INST
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: R-2
ZONING: INST
1 2
{\f
Ar ia l|b 0| i0 |c0
|p
} 2
KI
M
LE
Y-
HO
RN
A
ND
A
SS
O
CI
AT
ES
, I
NC
BY
R E
V
IS
IO
N
S No
DATE
T h is d o cu m e n t, t o g e th e r w ith t h e c o n ce p ts a n d d e si g n s p re se n te d h e re in a s a n in st ru m e n t o f se rv ic e is in te n d e d o n ly f o r th e s p e ci fic p u rp o se a n d c lie n t fo r w h ic h it w a s p re p a re d R e u se o f a n d im p ro p e r re lia n ce o n t h is d o cu m e n t w ith o u t w ri tt e n a u th o ri za tio n a n d a d a p ta tio n b y K im le y- H o rn a n d A ss o ci a te s, I n c.
s h a ll b e w ith o u t lia b ili ty t o K im le y- H o rn a n d A ss o ci a te s, I n c.
D A T E
A S
S H
O W
N
SHEET NUMBER
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
K H
A P
R O
JE
C
T
D A
T E
L
IC
E N
S E
D P
R O
F E
S S
IO
N
A L
W W
W .K
IM
L E
Y -H
O R
N .C
O M
R
E G
IS
T
R Y
E
A S
T S
IL
V
E R
S P
R
IN
G S
B L
V D
S
U
IT
E
O
C A
L A
F
L
P H
O N
E -4
-3
TA
H
R
VB
KH
A
N W
TH
A
VE
N U
E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
F
O R
TH
E
C
IT
Y O
F O
C
AL
A F
LO
R
ID
A C
IT
Y
O F
O C
A L A
J U
N E
N O
T F
O R
C O
N S
T R
U C
T
IO
N
{\W 0.7
5;R
IC
HA
RD
V . B
US
CH
E, P
.E
{\W 0.
;F
LO
RI
DA
L
IC
EN
SE
N
UM
BE
R}
SI
TE
P
LA
N
C-03
NORTH
GRAPHIC SCALE IN FEET
10 20 40
\A1;70' MIN. LOT WIDTH
7,000 SQ. FT.
MIN. LOT SIZE
TYPICAL LOT SETBACKS DETAIL
N.T.S.
*1
REAR
F R
O N
T
*8'
SIDE
*8'
SIDE
\A 1;
VA
RI
ES
\A1;* STREET SIDE YARD AND STREET REAR YARD SETBACKS SHALL BE 20'
1 - 24" WHITE THERMOPLASTIC STOP BAR
HC - ACCESSIBLE CURB RAMP (PER FDOT
STANDARD PLANS INDEX 522-002)
2 - RELOCATE EXISTING STOP SIGNS WITH STREET PADDLES
NOTES:
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY REGULATIONS AND CODES AND O.S.H.A.
STANDARDS.
2. PRIOR TO CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, THE CONTRACTOR SHALL
OBTAIN ALL NECESSARY PERMITS FROM THE AUTHORITY HAVING JURISDICTION.
3. SITE BOUNDARY, TOPOGRAPHY, UTILITY AND ROAD INFORMATION PER SURVEY DATED AUGUST 13, 2019 JCH CONSULTING GROUP, INC.
4. THE SITE CONSTRUCTION STAKEOUT SHALL BE PERFORMED UNDER THE DIRECTION OF A FLORIDA SURVEYOR. AUTOCAD FILES WILL BE FURNISHED TO AID IN THE SITE CONSTRUCTION STAKEOUT. ANY DISCREPANCIES FOUND BETWEEN AUTOCAD FILES AND THE SITE CONSTRUCTION PLANS SHALL BE
BROUGHT TO THE ENGINEER'S ATTENTION FOR CLARIFICATION PRIOR TO THAT STAKEOUT.
PARCEL IDENTIFICATION NUMBERS
TOTAL SITE BOUNDARY
SITE DATA TABLE
2840-017-001, 2840-017-002, 2840-017-003, 2840-017-004, 2840-017-005, 2840-017-006, 2840-017-007, 2840-017-101, 2840-017-102, 2840-017-202, 28509-000-00, 28511-000-000 AND 28512-000-000
1.48 ACRES
FLOOD ZONE X
FEMA PANEL 12083C05O9E
BUILDING SETBACKS
INTERIOR SIDE YARD
MAXIMUM BUILDING HEIGHT
20 FEET
35 FEET
FRONT YARD 20 FEET
STREET SIDE YARD
8 FEET
ZONING
LAND USE NEIGHBORHOOD
R-2
15 FEETINTERIOR REAR YARD
20 FEETSTREET REAR YARD
MINIMUM LOT WIDTH 70 FEET
MINIMUM LOT AREA 7,000 SQUARE FEET
LEGEND
- ASPHALT PAVEMENT
(SEE DETAIL SHEET C-06)
- CONCRETE SIDEWALK
(SEE DETAIL SHEET C-06)
3 - RELOCATE EXISTING GRADE CROSSING ADVANCE WARNING SIGN
4 - REPLACE HIGHWAY-RAIL GRADE CROSSING PAVEMENT MARKING
- TREES TO BE PRESERVED
- TREES TO BE REMOVED
- BUILDING SETBACK LINES
http://WWW.KIMLEY-HORN.COM
F.F.E. = 72.80
F.F.E. = 71.50
F.F.E. = 70.50 F.F.E. = 70.00
F.F.E. = 70.70
F.F.E. = 72.801
PARK
F.F.E. = 72.70
N W
7T H
AV
EN
U E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
FO
R
TH
E
C
IT
Y O
F O
C
AL
A G
R
AD
IN
G
PL
AN
C-04
NORTH
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
LEGEND
PAVEMENT LEGEND
- ASPHALT PAVEMENT
(SEE DETAIL SHEET C-06)
NOTES:
1. MAXIMUM RUNNING SLOPE ON SIDEWALKS SHALL NOT EXCEED 5.00%
(1:20).
2. MAXIMUM CROSS SLOPE ON SIDEWALKS SHALL NOT EXCEED 2.00% (1:48).
3. SEE TYPICAL LOT GRADING DETAILS ON SHEET C-06
- TREES TO BE PRESERVED
- TREES TO BE REMOVED
- PROPOSED SPOT ELEVATION (ALL POINTS ARE LOCATED
AT EDGE OF PAVEMENT, UNLESS OTHERWISE NOTED)
- PROPOSED SPOT ELEVATION AT LOT CORNERS
- PROPOSED CONTOURS
- EXISTING CONTOURS
- PROPOSED FLOW DIRECTION ARROWS
- CONCRETE PAVEMENT
(SEE DETAIL SHEET C-06)
- BUILDING SETBACK LINES
SSMH #3486
SSMH #3367 SSMH #3366 SSMH #3365
8" C
LA
Y
6" CLAY
C L A
Y
8" CLAY
8" CLAY
8" CLAY
N.
W
. 7
TH
A
VE
NU
E
(S
IG
N)
N.
W
. 8
TH
A
VE
NU
E
(S
IG
N)
N.W. 5TH ST. (SIGN)
N.W. 6TH STREET (SIGN)
18' ASPHALT
' A
S P
H A
LT
' A
S P
H A
LT
18' ASPHALT
\A1;35.3'
\A1;36.5'
\A1 ;14
.8'
\A 1;4
0.0
\A1 ;25
.0' \A
1;2 5.0
\pxqc;NORTHERLY RIGHT OF WAY OF CSX RAILROAD
C
C
\pxqc;TREE DRIPLINE
\pxqc;TREE DRIPLINE
\pxqc;TREE DRIPLINE
EXISTING R/W
EXISTING R/WEXISTING R/W
EXISTING R/W
EXISTING 8"
WATER MAIN
EXISTING 8"
WATER MAIN
OPEN CUT EXISTING ROADWAY PER CITY
OF OCALA TRENCH WIDTH PAVEMENT
REPLACEMENT DETAIL #478-6.1 (TYP.)
2 3
PARK
CONNECT TO EXISTING
SANITARY MAIN PER
CITY OF OCALA
SANITARY SERVICE
DETAIL #498-2.1 (TYP.)
SINGLE SEWER SERVICE (TYP.)
DOUBLE WATER SERVICE (TYP.)
EXISTING FIRE
HYDRANT
EXISTING
FIRE
HYDRANT
CONNECT TO EXISTING
WATER MAIN PER CITY OF
OCALA WATER MAIN TAP
DETAIL #488-3.2B (TYP.)
400 LF FIRE HYDRANT PATH
400 LF FIRE HYDRANT PATH
400 LF FIRE HYDRANT PATH
SINGLE WATER SERVICE (TYP.)
OCALA ELECTRIC TO
ADJUST EXISTING
POLES/OTHERS
273 LF OF
8" SDR 26 @ 0.45%
INSTALL: 2"X2" PVC TEE
AND 2"X4" REDUCER
INSTALL: 4" GATE VALVE
WITH CONCRETE PAD
INSTALL: 4"X8" REDUCER
INSTALL: 8" PVC
WATER MAIN
INSTALL: 8"X8" SADDLE
TAP WITH 8" GATE VALVE
WITH CONCRETE PAD
INSTALL: 4" PVC
WATER MAIN
DOUBLE WATER SERVICE (TYP.)
C.O. (TYP)
C.O. (TYP)
EXISTING 2"
WATER MAIN
{\f
Ar ia l|b 0| i0 |c0
|p
} 2
KI
M
LE
Y-
HO
RN
A
ND
A
SS
O
CI
AT
ES
, I
NC
BY
R E
V
IS
IO
N
S No
DATE
T h is d o cu m e n t, t o g e th e r w ith t h e c o n ce p ts a n d d e si g n s p re se n te d h e re in a s a n in st ru m e n t o f se rv ic e is in te n d e d o n ly f o r th e s p e ci fic p u rp o se a n d c lie n t fo r w h ic h it w a s p re p a re d R e u se o f a n d im p ro p e r re lia n ce o n t h is d o cu m e n t w ith o u t w ri tt e n a u th o ri za tio n a n d a d a p ta tio n b y K im le y- H o rn a n d A ss o ci a te s, I n c.
s h a ll b e w ith o u t lia b ili ty t o K im le y- H o rn a n d A ss o ci a te s, I n c.
D A T E
A S
S H
O W
N
SHEET NUMBER
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
K H
A P
R O
JE
C
T
D A
T E
L
IC
E N
S E
D P
R O
F E
S S
IO
N
A L
W W
W .K
IM
L E
Y -H
O R
N .C
G
IS
T
R Y
E
A S
T S
IL
V
E R
S P
R
IN
G S
B L
V D
S
U
IT
E
O
C A
L A
F
L
P H
O N
E -4
-3
TA
H
R
VB
KH
A
N W
TH
A
VE
N U
E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
F
O R
TH
E
C
IT
Y O
F O
C
AL
A F
LO
R
ID
A C
IT
Y
O F
O C
A L A
J U
N E
N O
T F
O R
C O
N S
T R
U C
T
IO
N
{\W 0.7
5;R
IC
HA
RD
V . B
US
CH
E, P
.E
{\W 0.
;F
LO
RI
DA
L
IC
EN
SE
N
UM
BE
R}
U
TI
LI
TY
P
LA
N
C-05
NORTH
GRAPHIC SCALE IN FEET
10 20 40
Know what's below.
Call before you dig.
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
SS-XX - SANITARY MANHOLE LABEL
- GATE VALVE
- TEE
- BENDS
- PROPOSED SANITARY MANHOLE
- FIRE HYDRANT ASSEMBLY
- PROPOSED SANITARY SEWER PIPE
- PROPOSED WATER LINE
LEGEND
BT-1
- BACT. SAMPLE POINT
NOTES:
1. ALL UTILITY CONSTRUCTION SHALL CONFORM WITH THE CITY
OF OCALA STANDARD SPECIFICATIONS FOR WATER AND SEWER
CONSTRUCTION, LATEST EDITION. THE CONTRACTOR IS
RESPONSIBLE FOR BECOMING FAMILIAR WITH ALL RULES AND
STANDARDS CONTAINED THEREIN.
2. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER
NOTIFICATION OF INSPECTING AUTHORITIES BEFORE AND
DURING CONSTRUCTION.
3. SEE SHEET C-07 FOR UTILITY DETAILS.
4. ALL POTABLE WATER MAINS SHALL BE POLYVINYL CHLORIDE
(PVC), ANSI/AWWA C-900, DR18, 150 PSI PRESSURE RATING,
UNLESS OTHERWISE NOTED. PROVIDE A MINIMUM 48" COVER
FROM FINISHED GRADE.
5. ALL SANITARY SEWER MAINS SHALL BE POLYVINYL CHLORIDE
(PVC), ASTM D-3034, SDR-26, UNLESS OTHERWISE NOTED.
6. UTILITY AS-BUILT DRAWINGS, MEETING THE CITY OF OCALA
WATER AND SEWER CONSTRUCTION MANUAL REQUIREMENTS,
ARE TO BE SUPPLIED TO THE CITY PRIOR TO ISSUANCE OF THE
C.O..
7. POTABLE WATER DEMANDS:
2,100 GAL/DAY
SEWER DEMANDS:
1,925 GAL/DAY
IRRIGATION DEMANDS:
0 GAL/DAY
8. ANY WATER MAIN OR WATER SERVICE 2 INCH OR ABOVE IN SIZE
ARE TO HAVE GATE VALVES INSTALLED. ANY 2 INCH OR LARGER
VALVE IS REQUIRED TO HAVE A VALVE TIE SHEET SUPPLIED
WITH THE UTILITY AS-BUILT DRAWINGS.
SSMH #3365
RIM = 70.58'
N INV. = 62.49'
E INV. = 62.18'
W INV. = 62.26'
SSMH #3364
RIM = 70.79'
E INV. = 61.08'
W INV. = 61.08'
SSMH #3486
RIM = 68.95'
N INV. = 64.70'
S INV. = 64.75'
W INV. = 64.80'
SSMH #3367
RIM = 70.66'
E INV. = 63.15'
S INV. = 63.18'
W INV. = 63.28'
SSMH #3366
RIM = 71.06'
N INV. = PLUGGED
E INV. = 62.87'
S INV. = 65.50'
W INV. = 62.88'
EXISTING MANHOLE STRUCTURES
PROPOSED MANHOLE STRUCTURES
SS-01
SANITARY SEWER DOGHOUSE MANHOLE
CITY OF OCALA DETAIL 498-1.1A & 498-1.2G
N: 1766236.4336 E: 609838.1279
RIM: 70.05
INV IN: 61.81, (S) 8" PVC SDR 26
INV IN: 61.81, (W) 8" CLAY, EXISTING
INV OUT: 61.81, (E) 8" CLAY, EXISTING
SS-02
SANITARY SEWER MANHOLE
CITY OF OCALA DETAIL 498-1.1A
N:1765963.1894 E: 609836.5531
RIM: 67.22
INV OUT: 63.04, (N) 8" PVC SDR 26
W
7T H
AV
EN
U E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
FO
R
TH
E
C
IT
Y O
F O
C
AL
A
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
C-06
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
SIDEWALK CONSTRUCTION
SIDEWALK JOINTS
PLAN
SECTION VIEW
NEW ASPHALT PAVEMENT
TIE-IN TYPICAL SECTION
LOT GRADING DETAIL - TYPE "A"
(DRAINAGE TO STREET)
LOT GRADING DETAIL - TYPE "B"
(DRAINAGE TO BOTH STREET AND REAR LOT LINE)
3 TYPICAL ROAD SECTION
4 3
5 5
{\f
Ar ia l|b 0| i0 |c0
|p
} 2
KI
M
LE
Y-
HO
RN
A
ND
A
SS
O
CI
AT
ES
, I
NC
BY
R E
V
IS
IO
N
S No
DATE
T h is d o cu m e n t, t o g e th e r w ith t h e c o n ce p ts a n d d e si g n s p re se n te d h e re in a s a n in st ru m e n t o f se rv ic e is in te n d e d o n ly f o r th e s p e ci fic p u rp o se a n d c lie n t fo r w h ic h it w a s p re p a re d R e u se o f a n d im p ro p e r re lia n ce o n t h is d o cu m e n t w ith o u t w ri tt e n a u th o ri za tio n a n d a d a p ta tio n b y K im le y- H o rn a n d A ss o ci a te s, I n c.
s h a ll b e w ith o u t lia b ili ty t o K im le y- H o rn a n d A ss o ci a te s, I n c.
D A T E
A S
S H
O W
N
SHEET NUMBER
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
K H
A P
R O
JE
C
T
D A
T E
L
IC
E N
S E
D P
R O
F E
S S
IO
N
A L
W W
W .K
IM
L
E Y
-H O
R N
.C
G
IS
T R
Y
E
A S
T S
IL
V
E R
S P
R
IN
G S
B L
V D
S
U
IT
E
O
C A
L A
F
L
P H
O N
E -4
-3
TA
H
R
VB
KH
A
N W
TH
A
VE
N U
E
SU
BD
IV
IS
IO
N
PR
EP
AR
ED
F
O R
TH
E
C
IT
Y O
F O
C
AL
A F
LO
R
ID
A C
IT
Y
O F
O C
A L A
J U
N E
N O
T F
O R
C O
N S
T R
U C
T
IO
N
{\W 0.7
5;R
IC
HA
RD
V . B
US
CH
E, P
.E
{\W 0.
;F
LO
RI
DA
L
IC
EN
SE
N
UM
BE
R}
U
TI
LI
TY
D
ET
AI
LS
C-07
TA
H
R
VB
Know what's below.
Call before you dig.
CALL 2 BUSINESS
DAYS BEFORE
YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
VICINITY MAP:
SHEET 1 OF 2
ONE IS NOT COMPLETE WITHOUT THE OTHER
SEE SHEET 2 OF 2 TOPOGRAPHIC DATA
TO
PO
G
RA
PH
IC
S
UR
VE
Y
-F O
R- C
ITY
O
F O
C A
LA
SUBJECT
AREA
C O
N S
U L
T I N
G
G
R O
U P
I N
C
J
C
H
L A
D
D
V
E L
O P
M E
N T
S
U R
V E
Y I N
G
A P
P I N
G
P L
A N
N I N
V I R
O N
M E
N T
I S
C E
R T
I F
I C
A T
E
O
F
A
U T
H O
R I Z
A T
I O
N
N
B
C H
R I S
T O
P H
J
H
O W
S O
N
P
S
M
C
F
M
L
S
W
B
L I T
C H
T O
N
R
O A
D
O
C A
L A
F
L O
R I D
A
P H
O N
E
F
X w w w
J C
H c g c o m
RECORD DESCRIPTION:
UTILITY CONTACTS:
FLOOD CERTIFICATION:
NOTES:
SURVEYOR'S CERTIFICATION:
TREE LEGEND:
LEGEND AND ABBREVIATIONS:
AutoCAD SHX Text I HEREBY CERTIFY THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF HEREBY CERTIFY THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF HEREBY CERTIFY THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF CERTIFY THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF CERTIFY THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF THIS SURVEY MEETS THE APPLICABLE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF THIS SURVEY MEETS THE APPLICABLE STANDARDS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .