ITB_CDS260622_Residential_Rehabilitation_-_Wiggington_123_SW_11th_Avenue_Ocala_-_EXHIBIT_D_-_Asbestos_Survey_Report.pdf

PDF 4 MB Posted

Attached to
Residential Rehabilitation - Wiggington (123 SW 11th Avenue, Ocala)
Solicitation number
ITB# CDS/260622
Issued by
Marion County, Orlando City, Florida

About this file

This is an Asbestos Survey Report prepared by Pb3 Environmental Monitoring, LLC for the City of Ocala Community Development Services Department regarding residential rehabilitation work at 123 SW 11th Avenue, Ocala, Florida. The survey was conducted on December 16, 2025, by EPA/AHERA-trained professional inspectors holding Florida Asbestos Business Organization License No. ZA527 and U.S. EPA Certification for Lead-Based Paint Activities (Firm No. NAT-F178890). The report documents the identification and classification of asbestos-containing materials (ACM) found throughout the subject property that would be disturbed during the proposed demolition and renovation activities. The inspection followed EPA protocols, with suspect homogeneous materials categorized as surfacing materials, thermal system insulation (TSI), or miscellaneous materials, and bulk samples were collected and analyzed using Polarized Light Microscopy (PLM) by NVLAP-accredited laboratories to determine asbestos content and friability classification.

The report emphasizes significant inspection limitations inherent to visual surveys, noting that concealed locations of asbestos may exist within wall voids, under flooring, behind finished surfaces, and within mechanical equipment that were not accessible during the assessment. The survey assumes that certain materials such as roofing material, vinyl flooring, floor mastic, fire doors, and cloth-jacketed electrical wiring contain asbestos unless specifically sampled and verified otherwise. The report specifies that suspect materials encountered during demolition activities that were not previously identified should be assumed to contain asbestos until laboratory analysis proves otherwise. As an unofficial report signed electronically on December 17, 2025, by Peter C. Swarr, PE (License #44159FL, LAC #63), this document serves as a program-planning tool for the City of Ocala's rehabilitation project and is intended exclusively for the client's use in planning renovation and demolition activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pb 3 Environmental Monitoring, LLC.

Asbestos, Lead Paint and Construction Air Monitoring Consulting Bulk Sampling for Laboratory Analysis

(352) 203-4081 email: robpbo3@gmail.com or rrasmussen72@gmail.com

FL Licensed Asbestos Business Organization No. ZA527 U.S. EPA Certified Lead-Based Paint Activities Firm No. NAT-F178890

6548 SW 131st Place Ocala, FL 34473 352.203.4081

December 16, 2025

Project:

Asbestos Survey for Renovation-House

Mae Etta Green Wigington 123 SW 11th Ave.

Ocala, FL 34471

Client:

City of Ocala

Community Development Services Department 201 SE 3rd St.

Ocala, FL 34471

Unofficial without seal Peter Swarr, PE #44159FL

LAC #63

Signed electronically 12/17/2025 by Peter C. Swarr, PE

Exhibit D - Asbestos Survey Report Contract# CDS/260622

D - 1

Asbestos Survey for Renovation-House Mae Etta Green Wigington 123 SW 11th Ave.

Ocala, FL 34471

PbO3 ENVIRONMENTAL MONITORING, LLC. 352.203.4081

ASBESTOS LICENSE # ZA527

According to your instructions PbO3 Environmental Monitoring, LLC., Inc. has completed an asbestos survey at the subject property (Project). The following pages of this report contain the results of this Inspection. This limited asbestos inspection report presents data that describes the location of asbestos-containing material (ACM) identified in the subject property. This report is to be used as a program-planning tool for the proposed demolition, renovation, construction and/or maintenance activities scheduled at this facility. This survey was conducted on site by EPA/AHERA trained professional inspector(s).

Suspect materials not previously identified in this report may be encountered during any renovation or demolition.

These materials should be assumed asbestos containing material until sample collection and subsequent analysis prove otherwise.

This report is intended for the exclusive use of our client. The findings are relevant to the conditions observed during the physical process of performing the Inspection. These findings should not be treated as absolute, nor should they be relied upon to represent conditions at significantly later dates.

PbO3 Environmental Monitoring, LLC.

Robert Rasmussen Building Inspector Asbestos License # ZA527

D - 2

ASBESTOS LICENSE # ZA527

1.0 INTRODUCTION

PbO3 was contracted by our client to conduct an Asbestos Survey of suspect asbestos containing materials found in the subject property.

1) Identify suspect asbestos-containing materials that would be disturbed during demolition and/or select renovations to this structure.

1.1 INSPECTION AND SAMPLING PROCEDURE

PbO3 inspection and sample collection procedures are based on the Environmental Protection Agency (EPA) protocols.

An initial facility walk through is conducted to familiarize the inspector with the facility layout. The facility is then divided into functional available spaces that can be accessed. The suspect homogeneous materials are selected for bulk sampling. Samples are collected and placed into separate, sealed plastic bags. Each sample is individually numbered, and sample information is entered onto a Field Data Sheet. Sample tools are decontaminated after each sample collection. The samples are delivered to an accredited laboratory for analysis, accompanied by a completed Chain of Custody Form.

Suspect materials are divided into three categories: surfacing materials (such as plaster and surface coatings), thermal system insulation (TSI) (such as mudded TSI fittings, duct insulation, and pipe insulation), and miscellaneous material (such as floor tile, drywall, and mastic). Asbestos-containing materials are classified according to:

Friability * Friable

* Non-friable

Friable asbestos-containing material (ACM), is defined as any material containing more than one percent (1%) asbestos as determined using the method specified in Appendix A, Subpart F, 40 CFR Part 763, Section 1, Polarized Light Microscopy (PLM), that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. (Sec. 61.141)

Nonfriable ACM is any material containing more than one percent (1%) asbestos as determined using the method specified in Appendix A, Subpart F, 40 CFR Part 763, Section 1, Polarized Light Microscopy (PLM), that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. EPA also defines two categories of nonfriable ACM, Category I and Category II nonfriable ACM, which are described later in this guidance.

"Regulated Asbestos-Containing Material" (RACM) is (a) friable asbestos material, (b) Category I nonfriable ACM that has become friable, (c) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or (d) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations.

A particular suspect material may be found in several different locations within a facility. The EPA does not require that these materials be sampled in each location, provided the materials are of the same type, age, appearance, have the same date of installation, and are sampled in accordance with EPA requirements to provide statistically reliable data that can be extrapolated onto all remaining non-sampled areas.

D - 3

ASBESTOS LICENSE # ZA527

Accredited inspectors determine the number of samples of each material to be collected, depending on the material's category and the amount of material present.

The EPA’s National Emission Standard for Hazardous Air Pollutants (NESHAP) regulations and the Florida Department of Environmental Protection (FDEP) Asbestos program regulate the removal and disposal of asbestos-containing building materials (any material containing more than 1% asbestos).

Asbestos NESHAP regulations must be followed for demolitions and/or renovations of facilities with at least 80 linear meters (260 linear feet) of regulated asbestos-containing materials (RACM) on pipes, 15 square meters (160 square feet) of regulated asbestos-containing materials on other facility components, or at least one cubic meter (35 cubic feet) of facility components where the amount of RACM previously removed from pipes and other facility components could not be measured before stripping.

1.2 METHODS OF LABORATORY ANALYSIS

Samples are analyzed in accordance with AHERA requirements using the following reference methods:

EPA Interim Method for the Detection of Asbestos in Bulk Insulation Samples (EPA 600/M4-82020, December 1982).

McCrone Research Institute's The Asbestos Particle Atlas.

All bulk samples are analyzed using PLM visual area estimate (VAE). Friable materials containing asbestos estimated at less than ten percent by PLM-VAE may be reanalyzed by PLM point counting. Additional treatment and tests may be used as required to accurately define composition (i.e., ashing, extractions, and TEM). All bulk sample laboratory reports are verified through an established quality assurance (QA) procedure.

1.3 QUALITY CONTROL PROCEEDURES

Laboratories accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) analyze all samples. These laboratories participate in the NVLAP, as well as the American Industrial Hygiene Association (AIHA) Bulk Asbestos Sample Quality Assurance Program. PbO3 verifies all sample data for accuracy by cross-referencing Field Data Sheets, Chain of Custody Forms, and field notes.

1.4 DETERMINATION OF ACM CLASSIFICATION

The positive identification of asbestos in a material or product can only be made through laboratory analysis.

Visual inspection or common knowledge is not a positive test. The asbestos content of a suspect material is determined by collecting a bulk sample and having it analyzed by PLM. The PLM technique determines the specific type of asbestos present in the bulk sample and VAE provides an estimate of the percentage of asbestos.

The EPA National Emission Standards for Hazardous Air Pollutants (NESHAP) - National Emission Standard for Asbestos (40 CFR Part 61, subpart M) defines a non-friable asbestos-containing material as any material with an asbestos content greater than one percent as determined by PLM analysis. A friable material estimated to

D - 4

ASBESTOS LICENSE # ZA527

contain less than ten percent asbestos as determined by PLM-VAE must be analyzed by PLM point counting and determined to contain less than one-percent asbestos in order to be considered a non-regulated ACM.

A clarification memorandum issued by the EPA regarding the NESHAP regulation included the following statement:

The parties legally responsible for a building (owner or operator) may take a conservative approach to being regulated by the NESHAP. The responsible party - may choose to act as though the building material is an asbestos-containing material (greater than 1%) at any level of asbestos content (even less than 1% asbestos).

Thus, if the analyst detects asbestos in the sample and estimates the amount to be less than 10% by visual estimation, the parties legally responsible (owner or operator) of the building may elect to assume the amount to be greater than 1% and treat the material as regulated asbestos containing material or require verification of the amount by point counting.

1.5 INSPECTION LIMITS

PbO3 has performed the Client requested tasks in a thorough and professional manner consistent with commonly accepted standard industry practices, using state of the art practices and best available known technology, as of the date of the assessment. PbO3 cannot guarantee and does not warrant that this Asbestos Survey has identified all adverse environmental factors and/or conditions affecting the subject properties on the date of the Assessment.

PbO3 cannot and will not warrant that this Asbestos Survey that was requested by the client will satisfy the dictates of, or provide a legal defense in connection with, any environmental laws or regulations. It is the responsibility of the client to know and abide by all applicable laws, regulations, and standards. The results reported and conclusions reached by PbO3 are solely for the benefit of the client. The results and opinions in this report, based solely upon the conditions found on the property as of the date of the Assessment, will be valid only as of the date of the Assessment. Please note that the test results relate only to those homogeneous materials tested. If conditions, or materials, other than those addressed in this report are encountered during the planned demolition activities, PbO3 should be contacted to assess the potential impact of these materials or conditions relative to the findings or recommendations included herein. The survey was performed by observing suspect materials throughout the structure where accessible. We must emphasize that it is not possible to look within every location of a building.

The visual survey documents only general locations of suspect materials but does not determine exact boundaries.

Concealed locations of asbestos may exist at the subject property, and the levels may vary from those stated in this report. There may be variations in the composition of materials which appear similar. Materials may be hidden from view and not accessible. Hypothetical examples include floor tile hidden under carpeting, and not detected by our typical examination of the area under the carpet at a corner(s) or existing hole(s), an abandoned length of insulated pipe hidden within a finished wall, an asbestos-cement sewer vent pipe in the wall behind a toilet, asbestos paper/felt between hardwood flooring and the sub-floor or old vinyl floor tile covered over with plywood and newer flooring materials. No attempt was made to disassemble equipment or demolish structural elements and finishes as this is beyond the scope of our authorized services. Visual observations were made only at convenient locations, due to these limitations, wall voids, flooring under carpet, building cavities and mechanical equipment, and other areas may contain unreported asbestos-containing materials. Suspect materials not previously identified in this report may be encountered during any demolition activity. These materials should be assumed asbestos containing material until sample collection and subsequent analysis prove otherwise.

D - 5

ASBESTOS LICENSE # ZA527

All fire doors should be assumed asbestos containing material since disassembly of locks and/or other work to access the door insulation is not possible.

We generally assume that roofing material, vinyl flooring and floor mastic contains asbestos, as asbestos roofing material, asbestos vinyl flooring and asbestos floor mastic are very common unless noted as sampled. Location and sampling of underground items, such as asbestos-cement pipes, would have been outside of the scope of the survey. Cloth jacketed electrical wiring if present, should be assumed asbestos containing material. Electrical wiring is typically not sampled unless the electrical system has been verified by our client as de-energized.

Electrical wiring is typically not sampled unless the electrical system has been verified by our client as de-energized. Swimming pools are not tested unless they are accessible and drained. Swimming pools should be assumed an asbestos containing material.

EPA 6001R-93/116 is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1 % or "None Detected" for these materials is recommended.

Quantities shown in this survey are estimates, actual quantities may vary. Field verification is the responsibility of the contractor. Contractors are responsible for their own verification of quantities prior to bid submittal.

Suspect materials not previously identified in this report may be encountered during any demolition, renovation and/or maintenance activities. These materials should be assumed asbestos containing material until sample collection and subsequent analysis prove otherwise.

1.6 INSPECTION DATE AND INSPECTOR INFORMATION:

PbO3 employee Julian Spadt inspected the structure on December 10, 2025.

2.0 FACILITY CONSTRUCTION INFORMATION:

The structure is a single-story wood framed single family house on CMU block piers with an asphalt shingle roof.

2.1 FACILITY MAINTENANCE AND/OR RENOVATION HISTORY

Unknown

D - 6

2.2 SUSPECT MATERIAL SUMMARY

Drywall with Joint Compound Ceiling Texture Rolled Vinyl Flooring (Tan) Exterior Caulking Asphalt Shingle Roofing CMU Block

2.3 RESULTS

There was a total of Seventeen (17) samples (including sub-samples) were analyzed by EPA Method 600/M4/82/020R-93/116. Based upon our visual observations, bulk sampling of suspect materials and subsequent microscopic analysis, we have determined that No Asbestos Containing Material was detected.

2.4 RECOMMENDATIONS

Suspect materials not previously identified in this report may be encountered during any demolition, renovation and/or maintenance activities. These materials should be assumed asbestos containing material until sample collection and subsequent analysis prove otherwise.

That this survey be used to identify asbestos containing material and components prior to any planned demolition, renovation, construction and/or maintenance activities scheduled at this facility.

Controlled “Wet” demolition of all materials in place is recommended. Provided the demolition activities do not subject presumed non-friable asbestos containing material (if present) to cutting, sanding, grinding, abrading, or otherwise rendering them friable during demolition.

29 CFR 1926.1101- OSHA's Asbestos Standard for the Construction Industry does apply to the demolition of all buildings identified with Asbestos Containing Material (ACM) and/or presumed ACM. The contractor will need to comply with the specific training, duties and responsibilities outlined in this CFR.

D - 7

ASBESTOS LICENSE # ZA527

General Recommendations

The EPA’s National Emission Standard for Hazardous Air Pollutants (NESHAP) regulations and the Florida Department of Environmental Protection (DEP) Asbestos program regulate the removal and disposal of asbestos-containing building materials. The Florida Department of Environmental Protection (DEP) administers an asbestos removal program under Chapter 62-257, Florida Administrative Code. The Asbestos NESHAP has been adopted by reference in section 62-204.800, Florida Administrative Code. The program’s intent is to minimize the release of asbestos fibers during activities involving the processing, handling, and disposal of asbestos-containing material.

The regulations of these agencies require the removal of friable asbestos-containing materials prior to extensive renovation or demolition projects, and the removal of non-friable asbestos-containing materials that may be rendered friable in the course of renovation or demolition projects. Only a Florida licensed asbestos contractor using properly trained, certified, and licensed asbestos workers can perform asbestos removal projects in Florida.

Air monitoring during and after abatement activities is also recommended to document the fiber levels inside and outside the abatement work area.

The asbestos NESHAP requires that an asbestos trained person be on site i.e. 40 CFR 61.145 (c) (8) states in part “no RACM shall be stripped, removed, or otherwise handled or disturbed at a facility regulated by this section unless at least one on-site representative, such as a foreman or management level person or other authorized person, trained in the provisions of this regulation and the means of complying with them is present.”

DEP recommends that this “trained person” be on site when non-friable ACM is present so that developing problems can be caught early and corrected without delay. In addition, the regulations require the owner of the building and/or the operator to notify the applicable DEP District Office or Local Pollution Control Agency before any demolition, or before renovations of buildings that contain a certain threshold amount of asbestos or asbestos containing materials.

Florida requires the submission of a 10-Day Notification for all renovations and demolitions of facilities with at least 260 linear feet of regulated asbestos-containing materials (RACM), 160 square feet of regulated asbestos containing materials on other facility components, or at least one cubic meter (35 cubic feet) off facility components. Asbestos waste requires disposal at an approved solid waste disposal facility.

Local agencies may also have specific requirements for demolition/renovation projects involving asbestos-containing building materials.

OSHA 29 CFR 1910.1001 requires the communication of information concerning asbestos hazards. Employees engaged in work activities with installed ACM may be exposed to asbestos fibers. The owner or operator should take the necessary steps to reduce the potential for disturbance.

29 CFR 1926.1101- OSHA's Asbestos Standard for the Construction Industry does apply to the abatement, renovation and/or demolition of all buildings identified with asbestos containing material. The contractor will need to comply with the specific training, duties and responsibilities outlined in this CFR.

D - 8

Dear Customer:

PbO3 Environmental Monitoring Company would like to thank you for allowing us the opportunity to be of service to you.

We value our customers and therefore PbO3 prides itself on making sure every customer is fully satisfied.

If there is ever another opportunity that we can be of service to you, we would appreciate the call. The services we provide for future reference are as follows.

Lead Testing and Consulting, Paint, Soil, Water and Dust.

Asbestos Testing, Consulting and Monitoring.

Indoor Air Quality Testing.

Mold Assessments and Clearances.

And various other environmental issues.

If you should have any questions, comments, or concerns please contact us at (352) 203-4081. Once again, thank you for using PbO3.

Sincerely, PbO3 Environmental Monitoring, LLC

D - 9

APPENDIX A

LABORATORY RESULTS

D - 10

Asbestos Bulk Analysis Report

Client:

Report Number:

Project/Test Address:

Client Number:

Reported Date:

Received Date:

Analyzed Date:

PbO3 Environmental Monitoring, LLC 12/15/2025

201413

12/16/2025

25-12-02885

Renovation; 123 SW 11th Ave; Ocala, FL 34471

Laboratory Results Fax Number:

321-507-4914

6548 SW 131st Place Ocala, FL 34473

12/16/2025

Layer Type AsbestosClient Sample Number

Other Materials

Lab Gross DescriptionLab Sample Number

7469 Whitepine Rd

Telephone: 800.347.4010

North Chesterfield, VA 23237

Gray Powdery; Brown Fibrous; Inhomogeneous

25-12-02885-001A 123-01 15% Cellulose 85% Non-Fibrous

Drywall NAD

White Chalky;

Homogeneous

25-12-02885-001B 123-01 100% Non-FibrousJoint Comp.

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

25-12-02885-002A 123-02 15% Cellulose 85% Non-Fibrous

Drywall NAD

White Chalky;

Homogeneous

25-12-02885-002B 123-02 100% Non-FibrousJoint Comp.

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

25-12-02885-003A 123-03 15% Cellulose 85% Non-Fibrous

Drywall NAD

1 of 4Page

D - 11

White Chalky;

Homogeneous

25-12-02885-003B 123-03 100% Non-FibrousJoint Comp.

NAD

White Textured; White Paint-Like;

Inhomogeneous

25-12-02885-004 123-04 100% Non-FibrousNAD

White Textured; White Paint-Like;

Inhomogeneous

25-12-02885-005 123-05 100% Non-FibrousNAD

White Textured; White Paint-Like;

Inhomogeneous

25-12-02885-006 123-06 100% Non-FibrousNAD

Tan Vinyl; White Foam;

Inhomogeneous

25-12-02885-007 123-07 5% Fibrous Glass 95% Non-Fibrous

NAD

Tan Vinyl; White Foam;

Inhomogeneous

25-12-02885-008 123-08 5% Fibrous Glass 95% Non-Fibrous

NAD

Tan Vinyl; White Foam;

Inhomogeneous

25-12-02885-009 123-09 5% Fibrous Glass 95% Non-Fibrous

NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201413 25-12-02885

Renovation; 123 SW 11th Ave; Ocala, FL 34471

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

2 of 4Page

D - 12

White Pliable; White Granular; Pink Paint-Like;

Inhomogeneous

25-12-02885-010 123-10 100% Non-FibrousNAD

White Pliable; White Granular; Pink Paint-Like;

Inhomogeneous

25-12-02885-011 123-11 100% Non-FibrousNAD

White Pliable; White Granular; Pink Paint-Like;

Inhomogeneous

25-12-02885-012 123-12 100% Non-FibrousNAD

Black Tar-Like;

Brown/White Aggregate;

Inhomogeneous

25-12-02885-013 123-13 15% Fibrous Glass 85% Non-Fibrous

NAD

Gray Granular;

Homogeneous

25-12-02885-014 123-14 100% Non-FibrousNAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201413 25-12-02885

Renovation; 123 SW 11th Ave; Ocala, FL 34471

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

3 of 4Page

D - 13

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201413 25-12-02885

Renovation; 123 SW 11th Ave; Ocala, FL 34471

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

Melissa Kanode

1% Asbestos

Analyst:

Reporting Limit:

Method:

QC Blank:

QC Sample:

Kathy Fletcher

EPA Method 600/R-93/116, EPA Method 600/M4-82-020

QA/QC Clerk

Reviewed By Authorized Signatory:

102-M12022-4

SRM 1866 Fiberglass

NAD = no asbestos detectedLEGEND:

These results are based on a comparative visual estimate. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite.

Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection. . NVLAP #101882-0 VELAP 460172

Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy

(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.

400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.

4 of 4Page

D - 14

ACCOUNT No.201413 Pb.3 ENVIRONMENTAL MONTTORING' LLC.

6548 SW 131" Place Ocala, FL 34473 (352) 203'4081rrasmtrssenT2(4grnail.com

CHAIN OF CUSTODY DOCUMENT PAGE

ilililrililtililililililrilillrilllilllllllllilllillilllil Due Date:

1211812025

Lab Name :

Address:

Environmental [Iazar, 7469 Vhitepine Road N. Chesterfield, \rA 23237

Turnaround:

Phone: 1-800-347-4010 cxt 11"

Same Dal'- 24 Hts- 48Hrs

3 Days J

Other

Analysis Tlpe:

Asbestos Bdk-X- Positive Stop--E- Lead

OTHE

(rhursda\il\./ Proiect Number:

Pro ject Name: ( .7,,o7,1,,i.1 ProjectAddresse3 Se. Uh Aw. OcalarFL. S4<?l

Client Name: (it1 o( ocala Inspector: ), fr*t+

Comments/MeaeutementsIrcatiooDescriptionDate Sample Number

Ae)roomt21- 6t ileu*ll -ith L,ht Gma*tlrdrcy'atr I I I

I

II I| -02 _I

LIIL I-o7 Thb..ha,+hclro"r,/e lLs. Tcrh,n- otl I t tLLL-ar II I

T ILL8"lA**,,-06 IL kll/*t-o7 Lt---.)

I I I-69 _T _TL

6.llo.n"o? ILT

Aoonr.2rpl),** ?(.6.*ti^.-lD lnin)n t (eulKin. 'll I I ItI I

I I I-( TI L-(e LLL

-t? I ril"ll (-l;^n Lf LJ}iu 9l-,<r -t(

**^,t, cLu e,"..t bllr.tl f at\ltnt

*;l{r u*h .olnt.t n4;^..r

J

TimcDater lJRelinquished Br Timc 1 r -,t41)-Daten. . t -.-'

25-12-02885

L Aodur.2to o.ll

Received Byy'

D - 15 w w w w w w w 4 w c 7 w w w 2 w w w w w w

Sample Key

Positive

Negative

Porch

123 SW 11th Ave.

Ocala, FL 34471

Porch w c c c c

01 10 05 06 09 04 02

D - 16

ASBESTOS LICENSE # ZA527

Sample 123-01 Sample 123-04 Sample 123-07 Typical Drywall & Joint Compound Typical Ceiling Texture Sample Typical Rolled Vinyl Flooring Sample Sample

Sample 123-10 Sample 123-13 Sample 123-14 Typical Exterior Caulking Sample Asphalt Shingle Roofing Sample CMU Block Sample

D - 17

APPENDIX B

CERTIFICATIONS

D - 18

Robert Rasmussen

July 18, 2025

ON-188748-7395-071825

18-Jul-2025

18-Jul-2026

Powered by TCPDF (www.tcpdf.org)

D - 19

Julian Spadt

April 23, 2025

ON-188748-9815-042325

23-Apr-2025

23-Apr-2026

Powered by TCPDF (www.tcpdf.org)

D - 20

Melanie S. Griffin, SecretaryRon DeSantis, Governor

STATE OF FLORIDA

DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION

ASBESTOS LICENSING UNIT

THE ASBESTOS BUSINESS ORGANIZATION HEREIN IS LICENSED UNDER THE

PROVISIONS OF CHAPTER 469, FLORIDA STATUTES

PBO3 ENVIRONMENTAL MONITORING, LLC

Do not alter this document in any form.

PETER C SWARR

LICENSE NUMBER: ZA527

EXPIRATION DATE: NOVEMBER 30, 2027

This is your license. It is unlawful for anyone other than the licensee to use this document.

6548 SW 131ST PLACE

OCALA FL 34473

Always verify licenses online at MyFloridaLicense.com

ISSUED: 09/05/2025

D - 21

United States Department of Commerce

National Institute of Standards and Technology

R

NVLAD ac M

Certificate of Accreditation to ISO/IEC 17025:2017

NVLAP LAB CODE: 101882-0

Environmental Hazards Services, L.L.C.

North Chesterfield, VA is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:

Asbestos Fiber Analysis

This laboratory is accredited in accordance with the recognized International Standard ISO/EC 17025:2017.

This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique on ISO/IEЕС 17025).

2025-01-01 through 2025-12-31

Effective Dates

O F

AM

ER

IC

A

C R E

MOC FO TNEMTRAPED

* UNITED

TES

T A

T amn For the National Voluntary Laboratory Accreditation Program

D - 22

National Voluntary Laboratory Accreditation Program NVLAP jlac-MRA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

Environmental Hazards Services, L.L.C.

7469 Whitepine Road

North Chesterfield, VA 23237-2261

Ms. Julie Dickerson

Phone: 804-275-4788 Fax: 804-275-4907

Email: jdickerson@leadlab.com http://www.leadlab.com

ASBESTOS FIBER ANALYSIS NVLAP LAB CODE 101882-0

Bulk Asbestos Analysis

Code

18/A01

18/A03

Description ЕРА -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples

EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials

Effective 2025-01-01 through 2025-12-31

Ttare Lamn For the National Voluntary Laboratory Accreditation Program

D - 23