ITB-25-006-RS_Attachment_B_-_Drawings_Final.pdf
PDF 6 MB Posted
- Attached to
- EASTMONTE PARK RESTROOM FACILITY (RE-BID) State and local contract opportunity
- Solicitation number
- ITB-25-006-RS
- Issued by
- Seminole County, Florida
About this file
The provided file is a comprehensive set of architectural and engineering drawings for the Eastmonte Park Restroom Facility project, prepared by Bentley Architects + Engineers for the City of Altamonte Springs, Florida. The drawings, marked as Attachment B for ITB-25-006-RS, detail a turn-key prefabricated precast modular restroom building located at 830 Magnolia Drive. The project includes a 720 square foot facility with separate men's and women's restrooms, an office, storage area, and plumbing chase, designed to accommodate up to 320 occupants. The plans specify a Type II-B unsprinklered construction with exterior finishes including brick, stucco, and concrete, and include detailed architectural, structural, mechanical, electrical, and plumbing specifications.
The drawings provide extensive technical details, including accessibility compliance, fixture layouts, electrical and mechanical systems, and construction methodologies. The facility will feature wall-mounted water closets and urinals, ADA-compliant fixtures, interior finishes with fiberglass reinforced panels and paint, and exterior paint in various shades including brick red, guild grey, and light French grey. Mechanical systems include a split system heat pump with ceiling-mounted cassette unit and outdoor condensing unit, while electrical systems will provide 200A service, LED lighting, receptacles, and exhaust ventilation. The project appears to be funded through municipal capital improvement resources, with a focus on creating a functional, durable, and accessible public restroom facility that meets current building codes and accessibility standards.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| ITB-25-006-RS__Notice_of_Intended_Action_Reject_-_Cancel_Bid.pdf | ||
| ITB-25-006-RS_Solicitation_Document_Final.pdf | ||
| VendorLink_Online_Submittal_Instructions_(as_of_03-30-2020).pdf | ||
| ITB-25-006-RS_Attachment_A-_Technical_Specifications_Rev._Final.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INVITATION TO BID
DOCUMENTS
ITB-25-006-RS
EASTMONTE PARK RESTROOM FACILITY
ATTACHMENT B-
DRAWINGS
CITY OF ALTAMONTE SPRINGS
City Hall, Suite 1030 Procurement Division
225 Newburyport Avenue Altamonte Springs FL 32701-3697
For Contract Information & Updates go to https://www.myvendorlink.com/cityofaltamontesprings/searchcontracts.aspx https://www.myvendorlink.com/cityofaltamontesprings/searchcontracts.aspx
** THIS PAGE LEFT INTENTIONALLY BLANK **
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:00 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-001
C O
V E
R S
H E
E T
EASTMONTE PARK RESTROOM
830 MAGNOLIA DRIVE
ALTAMONTE SPRINGS, FLORIDA
ARCHITECTS & ENGINEERS OF RECORD
651 WEST WARREN AVENUE, SUITE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
VENDOR NO. 59-3045321
BPE CA NO. 5898
BPA & ID CA NO. AAC002023
KEY PLAN PROJECT CONTACTS
ARCHITECTURE, STRUCTURAL:
BENTLEY ARCHITECTS + ENGINEERS, INC.
651 W. WARREN AVE. SUITE 200
LONGWOOD, FLORIDA 32750
(407) 331-6116 http://www.bentleygroupinc.com
BPA & ID CA NO. - AAC002023
GARY KRANSTON, R.A. 11541
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ENGINEERS:
SALAS O'BRIEN
3501 QUADRANGLE BLVD, SUITE 100
ORLANDO, FLORIDA 32817
(407) 380-0400 FAX
(407) 380-5900
FL. CERT. OF AUTH. NO. 6106
KYLE J. CARTIER, P.E. 53269
SITE LOCATION
VICTOR DIAZ, P.E. 55919
BRENTON DAILY, P.E. 81028
THE RESPONSIBLE PROFESSIONALS HEREBY CERTIFY THAT THIS DRAWING SET IS PROPERLY PREPARED AND ACCURATE TO THEIR BEST KNOWLEDGE AT THE
TIME OF SIGNATURE AND SEAL. THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY THE INDICATED ARCHITECT OR PROFESSIONAL
ENGINEER ON THE DATE INDICATED USING A DIGITAL SIGNATURE. PRINTED COPIES OF THE DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
X
DRAWING INDEX
Sheet # SHEET NAME 1 2 3 4
1. ARCHITECTURAL
AA-001 COVER SHEET
AA-002 GENERAL NOTES, SYMBOLS & ABBREVIATIONS
AA-004 LIFE SAFETY PLAN
AA-101 OVERALL FLOOR PLAN
AA-103 OVERALL REFLECTED CEILING PLAN
AA-104 OVERALL ROOF PLAN
AA-201 EXTERIOR ELEVATIONS
AA-301 BUILDING SECTIONS
AA-401 RESTROOM ACCESSIBLE DETAILS, ACCESSORIES
AND SIGNAGE DETAILS
AA-402 INTERIOR ELEVATIONS
AA-601 DOOR SCHEDULE, FINISH SCHEDULE, AND DETAILS
2. PLUMBING
AP-101 OVERALL FLOOR PLAN - PLUMBING
3. MECHANICAL
AM-101 OVERALL FLOOR PLAN MECHANICAL
4. ELECTRICAL
AE-101 OVERALL FLOOR PLAN - ELECTRICAL
A
A.A.R. AUTOMATIC AIR RELEASE
A/C AIR-CONDITIONING UNIT
ACOUS. ACOUSTIC
ADJ. ADJUSTABLE
A.F.F. ABOVE FINISH FLOOR
ALT. ALTERNATE
ALUM. ALUMINUM
ANT. ANTENNA
ARCHT. ARCHITECTURAL
B
BD. BOARD
B.U.R. BUILT-UP ROOFING
BLDG. BUILDING
BLKG. BLOCKING
BM. BEAM
BOT. BOTTOM
BRKT. BRACKET
C
C.C. CENTER TO CENTER
C.F. COUNTERFLASHING
CAP. CAPACITY
CEM. CEMENT
CLG. CEILING
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CTSK. COUNTERSINK
D
D.F. DRINKING FOUNTAIN
D.L. DEAD LOAD
D.S. DOWNSPOUT
DET. DETAIL
DFR. DEFLECTOR
DIA. DIAMETER
DIM. DIMENSION
DWG. DRAWING
E
E.A. EACH
E.C. ELECTRICAL CONDUIT
E.F. EXHAUST FAN
E.J. EXPANSION JOINT
ELEV. ELEVATION
EWC. ELECTRIC WATER COOLER
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
F
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.O. FRAMED OPENING
F.S. FLUE STACK
FIN. FL. FINISH FLOOR
FTG. FOOTING
G
G.S. GRAVEL STOP
GA. GAUGE
GALV. GALVANIZED
GL GLASS
GTR. GUTTER
G.W.B. GYPSUM WALL BOARD
H
H.B. HOSE BIB
H.M. HOLLOW METAL
H.P. HIGH POINT
HD. HEAD
HGT. HEIGHT
L
L.G. LONG
L.L. LIVE LOAD
L.P. LOW POINT
LAB. LABELED
LAV. LAVATORY
LBS. POUNDS
M
M.B. MODIFIED BITUMEN
M.O. MASONRY OPENING
M.T. METAL THRESHOLD
MIN. MINIMUM
N
N.I.C. NOT IN CONTRACT
NO. NUMBER
O
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.S. OVERFLOW SCUPPER
OBS. OBSCURE
OPNG. OPENING
P
PART. PARTITION
PBLG. PLUMBING
P.I.T. PITCH PAN
PL. PLATE
PLAS. PLASTER
PNLS. PANELS
P.P. PIPE PENETRATION
PRELIM. PRELIMINARY
PT. POINT
R
R. RISER
R.D. ROOF DRAIN
R.H. ROOF HATCH
R.V. ROOF VENT
R.W.L. RAIN WATER LEADER
RAD. RADIUS
REINF. REINFORCING
REQ. REQUIRED
RM. ROOM
S
S.B. SPLASH BLOCK
S.F. SUPPLY FAN
S.O. SPILL-OUT
S.S. STAINLESS STEEL
SH. SHOWER
SECT. SECTION
SHT. SHEET
SKY. SKYLIGHT
SL. SLOPE
SP.LT. SPOT LIGHT
SQ. SQUARE
STD. STANDARD
STL. STEEL
T
T. TREAD
TRANS. TRANSOM
TYP. TYPICAL
V
V. VINYL
V.I.F. VERIFY IN FIELD
V.T.R. VENT THRU ROOF
VERT. VERTICAL
VEST. VESTIBULE
W
W.S. WORKING SCUPPER
WD. WOOD
WDW. WINDOW
1. WORK SHALL COMPLY WITH APPLICABLE CODES INCLUDING
LOCAL CODE ORDINANCES AND MODIFICATIONS, AND THE
FLORIDA BUILDING CODE (FBC) CURRENT ADDITION.
2. MEASUREMENTS DERIVED BY THE GENERAL CONTRACTOR
BY MANUALLY SCALING THE DRAWINGS IS NOT AN
ACCEPTABLE MEANS OF DETERMINING MEASUREMENTS. ALL
MEASUREMENTS ARE TO BE DERIVED USING THE PRINTED
DIMENSIONS. WHERE PRINTED DIMENSIONS ARE INSUFFICIENT
OR IN CONFLICT, THE GENERAL CONTRACTOR MUST REQUEST
CLARIFICATION OF THE DIMENSIONS IN QUESTION FROM THE
ARCHITECT.
3. FIELD VERIFY THE ACCURACY OF ALL DIMENSIONS WITH
FIELD LAYOUT PRIOR TO PROCEEDING WITH THE WORK. IF
NECESSARY, REQUEST CLARIFICATION PRIOR TO
PROCEEDING WITH INSTALLATION. WHERE THE DRAWINGS
SPECIFICALLY INDICATE DIMENSIONS TO BE FIELD VERIFIED,
DO SO PRIOR TO INSTALLATION OF THE WORK AND
COORDINATE IF REQUIRED WITH THE ARCHITECT.
4. WHERE ENLARGED PLANS ARE REFERENCED, ADDITIONAL
DIMENSIONAL INFORMATION AND DETAIL INFORMATION ARE
PROVIDED IN THE ENLARGED PLANS. NOTIFY THE ARCHITECT
OF ANY CONFLICTS FOR CLARIFICATION PRIOR TO
PROCEEDING WITH THE WORK.
5. WHERE REQUIRED, FIELD VERIFY DIMENSIONS AS
REQUIRED PRIOR TO FABRICATION AND INSTALLATION OF
BUILT-IN ITEMS, IN ADDITION TO COMPLYING WITH THE
APPLICABLE CODES AND ACCEPTED TRADE PRACTICES AND
STANDARDS, MUST BE INSTALLED PER THE MANUFACTURER'S
RECOMMENDATIONS AND REQUIREMENTS TO INSURE FULL
WARRANTY AND OPERATIONAL FUNCTION.
6. THE GENERAL CONTRACTOR SHALL ISSUE HIS
SUBCONTRACTORS COMPLETE SETS OF CONSTRUCTION
DOCUMENTS TO INSURE THAT THE ENTIRE SCOPE OF WORK
NECESSARY TO COMPLETE THE PROJECT IS BID. WHETHER
THE GENERAL CONTRACTOR ELECTS TO ISSUE COMPLETE
SETS OR ONLY SELECTED DRAWINGS TO HIS
SUBCONTRACTORS, THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR COMPLETING THE ENTIRE SCOPE OF
WORK.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE
LATEST SET OF DRAWINGS THAT INCLUDES ANY ADDENDUM
OR REVISION TO HIS STAFF ON SITE AND HIS
SUBCONTRACTOR'S.
8. IF THERE ARE CONFLICTS IN THE CONSTRUCTION
DOCUMENTS AFFECTING QUALITY OF WORK, QUANTITY OF
WORK OR MATERIAL, SCOPE OF WORK, OR ANY OTHER
ASPECT OF THE WORK, THE GENERAL CONTRACTOR MUST
NOTIFY THE ARCHITECT FOR CLARIFICATION OF THE CONFLICT
DURING THE BID PHASE OF THE PROJECT. ABSENT WRITTEN
CLARIFICATION OF THE CONFLICT FROM THE ARCHITECT, THE
MOST STRINGENT INTERPRETATION OF THE CONFLICT SHALL
APPLY, AND UNDER NO CIRCUMSTANCES WILL THERE BE
ADDITIONAL COST TO THE OWNER PURSUANT TO THE
ARCHITECTS REVIEW AND INTERPRETATION OF THE
CONFLICT.
9. ANY DAMAGES TO THE BUILDING OR GROUNDS SHOULD BE
REPAIRED TO LIKE NEW CONDITION. ANY EXISTING
WARRANTIES TO BE MAINTAINED.
10. AS-BUILT DRAWINGS ARE TO BE PROVIDED THAT CLEARLY
INDICATES LOCATION OF ALL UNDERGROUND WORK
(SANITARY, ELECTRICAL, ETC.). DIMENSIONS SHOULD BE
INCLUDED FOR FUTURE REFERENCE AND USE.
GENERAL NOTES:
1t
H8 View Name 1/8" = 1'-0"
SYMBOL KEY:
DOOR
SYMBOL
WINDOW
SYMBOL
GRID LINE
TARGET
TITLE
ELEVATION
REFERENCES
NUMBERED BY TYPE
REFER TO SCHEDULE
NUMBERED BY TYPE
REFER TO SCHEDULE
A,B,C, ETC. IN ONE DIRECTION
1,2,3, ETC. IN THE OTHER
SCALE
DRAWING NUMBER
XX
XX
XX
W4 a-b
SECTION
REFERENCES
W4 a-bWALL TAG
WALL TYPE
SIM
A102A108
SIM
A102A108
SHEET NUMBER
DIRECTION
OF VIEW
SHEET NUMBER
DIRECTION
OF VIEW
LEVEL
REFERENCE
ROOF SLOPE
ARROW
SLOPE
DIRECTION
SLOPE
ROOF SLOPE
6 SLOPE
REVISION
MARK
ACCESSORY
TAG
NOTE TAG
XX
XX
LOCATION OF NOTE
APPLICATION
NOTE NUMBER
LOCATION OF NOTE
APPLICATION
LEVEL
CHANGE
XX
DETAIL
REFERENCES
SHEET NUMBER
DETAIL
AREA
INTERIOR
ELEVATIONS
SHEET NUMBER
DIRECTION
OF VIEW
VIEW
NUMBER
X
XX
X
X
XX
X
ROOM TAG
Room name
Room name
101 ROOM NUMBER
REV.
NUMBER
REV. LOCATION
XX CHANGE IN LEVEL
Name
Elevation
6:12
SIM
A102 A103
SIM
A102 A103
1 Ref
A101
1 Ref
A101
NOTE NUMBER
MATERIAL SYMBOLS:
EARTHWORK
CONCRETE
MASONRY
WOOD
GLASS
INSULATION
FINISHES
PLYWOOD
METAL
EARTH/COMPACT FILL
CONCRETE
BRICK
CONCRETE MASONRY
FINISH
ROUGH
BLOCKING
GLASS
BATT/LOOSE FILL
COMPOSITE RIGID
MINERAL WOOL
GYPSUM WALLBOARD
PLYWOOD
STEEL/OTHER METALS
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:01 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-002
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
B B
R E
V
IA
T
IO
N
ABBREVIATIONS
LIFE SAFETY INFORMATION
APPLICABLE CODES:
FLORIDA EXISTING BUILDING CODE, 2020
FLORIDA MECHANICAL CODE, 2020
FLORIDA PLUMBING CODE, 2020
NFPA 70, NATIONAL ELECTRICAL CODE, 2017
FLORIDA FIRE PREVENTION CODE, 2020 (7TH ED.)
FLORIDA ACCESSIBILITY CODE, 2020
FLORIDA ENERGY CONSERVATION CODE, 2020
LIFE SAFETY LEGEND
GROUP (A5) - ASSEMBLY - OUTDOOR
SPORTING EVENTS AND ACTIVITIES
OCC. AREA
#FT
1 FUNCTION
2 OCCUPANCY GROUP
3 AREA (SQ. FT)
4 OCCUPANCY FACTOR
5 OCCUPANCY LOAD
XXX
XXX
XXX
OCC. LOAD AT THIS EXIT
REQ. EXIT WIDTH
PROVIDED EXIT WIDTH
FE FIRE EXTINGUISHER (BRACKET MOUNTED),
PLACED EVERY 75' OF TRAVEL DIST.,
LOCATION TO BE APPROVED & VERIFIED BY
AHJ
PATH OF TRAVEL (EXIT ACCESS)
EXIT REQUIREMENTS
OCCUPANT LOAD CALCULATIONS
(TYPE II B UNPROTECTED, UNSPRINKLERED)
AREA TYPE PARK AREA OCCUPANTS OCC. LOAD
ASSEMBLY (A5) 320 MAXIMUM 320
TOTAL OCC. LOAD 320
MAX. TRAVEL DISTANCE TO EXIT
(FBC 1017.2):
COMMON PATH OF TRAVEL
(FBC 1006.2.1):
MAX. DEAD-END CORRIDOR
(FBC 1020.4):
MIN. EGRESS CORRIDOR WIDTH
(FBC 1020.2):
EGRESS WIDTH PER PERSON - DOOR:
MIN. CLEAR OPENING OF EXIT DOOR:
MIN. NUMBER OF EXITS REQUIRED BY FBC
*PER TABLE 1006.2.1 MAX. OCCUPANT
WITH ONE EXIT OR EXIT ACCESS
DOORWAY = 49
200 FT
75 FT
20 FT
44 IN
0.2 IN. X # OF OCC.
36 IN. (FBC ACCESSIBLE)
1*
EXIT CALCULATIONS
TOTAL OCC. LOAD
MIN. EGRESS WIDTH OF DOOR REQ.
TOTAL EXIT DOOR WIDTH PROVIDED
MIN. CLEAR WIDTH EXIT DOOR PROVIDED
BUILDING CODE SUMMARY
USE & OCC CLASSIFICATION:
CONSTRUCTION TYPE:
SPRINKLERED:
ASSEMBLY, GROUP A5 (FBC 303.6)
II-B (FBC CHAPTER 6; TABLE 601)
NO (NFPA 101, 2018)
32 INCHES
36 INCHES
36 INCHES
FLOOR AREA
TOTAL GROSS BUILDING AREA = 720 S.F.
NOTE: DESIGN IS BASED ON A MAXIMUM OF 320 OCCUPANTS FOR
PARK EVENTS. EVENTS EXCEEDING 320 OCCUPANTS REQUIRE
PORTABLE RESTROOM ACCOMMODATIONS.
PLUMBING FIXTURES:
WATER CLOSETS URINALS LAVATORIES
DRINKING
FOUNTAIN
1 REQD.
1 PROV.
0 REQD.
TABLE 403.1 MINIMUM NUMBER OF REQ. PLUMBING FIXTURES
GROUP (A5) - ASSEMBLY (A5)
OCCUPANT LOAD = 320
OCCUPANCY
GROUP
TOTAL REQUIRED
ASSEMBLY FEMALE
4 REQD.
MALE
4 PROV.TOTAL PROVIDED 2 PROV.
FEMALE MALE
3 REQD.
2 PROV.
2 REQD.
2 PROV.
2 REQD.
2 PROV.
SERVICE
SINK
1 REQD.
1 PROV.
NOTE: FBC, PLUMBING, SECTION 424.2: URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT
OF THE REQUIRED WATER CLOSETS IN ASSEMBLY OCCUPANCIES.
OFFICE
WOMEN'S
MEN'S
STORAGE
25'-0" TRAVEL DISTANCE
F E
PLUMBING
CHASE
15'-0" TRAVEL DISTANCE
T R
A V
E L D
IS
T
A N
C E
25'-0" TRAVEL DISTANCE
SERVICE
ACCESS ONLY
AA-301
THIS TABLE HAS A LOAD FACTOR OF 0.60*WIND
APPLIED. POSITIVE (+) & NEGATIVE (-) VALUES
SIGNIFY
PRESSURES ACTING TOWARD & AWAY FROM THE
SURFACE, RESPECTIVELY.
> 500
50 -26.5 -31.9
10 8.6 -21.1 -35.5 -53.4
POS (+) NEG (-) POS (+) NEG (-) POS (+) NEG (-)
AREA
(SQ.
FT)
INTERIOR
ZONE 1 (PSF)
EDGE ZONE 2
(PSF)
CORNER ZONE
3 (PSF)
NOMINAL COMPONENTS & CLADDING ROOF
PRESSURES
POSITIVE (+) & NEGATIVE (-) VALUES SIGNIFY
PRESSURES ACTING TOWARD & AWAY FROM THE
SURFACE, RESPECTIVELY.
> 500
50 -44.2 -53.1
10 14.3 -35.2 -59.1 -89.0
POS (+) NEG (-) POS (+) NEG (-) POS (+) NEG (-)
AREA
(SQ.
FT)
INTERIOR
ZONE 1 (PSF)
EDGE ZONE 2
(PSF)
CORNER ZONE
3 (PSF)
ULTIMATE COMPONENTS & CLADDING ROOF
PRESSURES
13.4 -34.3
12.2 -33.1
11.3 -32.2
-53.1 -74.0
-38.2 -38.2 -22.9 -22.9
8.1 -20.6 -31.9 -44.4
7.3 -19.9
6.8 -19.3
6.8
6.8
POSITIVE (+) & NEGATIVE (-) VALUES
SIGNIFY PRESSURES ACTING
TOWARD
& AWAY FROM THE SURFACE,
RESPECTIVELY.
> 500
50 -36.5
10 32.2 -34.9 -43.0
POS (+) NEG (-) POS (+) NEG (-)
AREA
(SQ.
FT)
INTERIOR
ZONE 4 (PSF)
CORNER
ZONE 5 (PSF)
ULTIMATE COMPONENTS &
CLADDING WALL PRESSURES
30.9 -33.6
29.3 -31.7
27.4 -30.1
26.1 -28.5
24.2 -26.9
-40.3
-33.6
-30.6
-26.9
11.3
11.3
-32.2
-32.2
14.3
13.4
12.2
11.3
11.3
11.3
14.3
13.4
12.2
11.3
11.3
11.3
-38.2
-38.2
-38.2
-38.2
8.6
8.1
7.3
6.8
6.8
6.8
8.6
8.1
7.3
6.8
6.8
6.8
-19.3
-19.3
-22.9
-22.9
-22.9
-22.9
THIS TABLE HAS A LOAD FACTOR OF
0.60*WIND APPLIED. POSITIVE (+) &
NEGATIVE (-) VALUES SIGNIFY
PRESSURES ACTING TOWARD & AWAY
FROM THE SURFACE, RESPECTIVELY.
> 500
50 -21.9
10 19.3 -21.0 -25.8
POS (+) NEG (-) POS (+) NEG (-)
AREA
(SQ.
FT)
INTERIOR
ZONE 4 (PSF)
CORNER
ZONE 5 (PSF)
NOMINAL COMPONENTS &
CLADDING WALL PRESSURES
18.5 -20.2
17.6 -19.0
16.4 -18.1
15.6 -17.1
14.5 -16.1
-24.2
-20.2
-18.4
-16.1
32.2
30.9
29.3
27.4
26.1
24.2
19.3
18.5
17.6
16.4
15.6
14.5
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:03 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-004
L
IF
E S
A F
E T
Y P
L A
N
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
1/2" = 1'-0"1
OVERALL LIFE SAFETY PLAN
WIND PRESSURE DIAGRAMS
OFFICE
WOMEN'S
MEN'S
STORAGE
MODULE 1
10' - 0"
MODULE 2
10' - 0"
MODULE 3
10' - 0"
6' - 4"1' - 11"
MIN.
1' - 6"3' - 4"5' - 2"
2' - 3 1/8"3' - 10"3' - 1"3' - 1"5' - 8"1' - 5"
10' - 0"
CLCLCLCL
CL
CL
CLCLCLCL
C L
C L
AA-402
AA-402
PLUMBING
CHASE
103B
10.004
22.013
10.004
T-3
T-7
22.002
T-7
T-3
22.002
T-2
T-1
T-2
T-1
T-1
T-2
22.002
T-3 T-7
T-4
T-6
22.008
T-5
22.006
22.007
22.009
T-6
T-5
T-4
T-6
T-7
T-3
TYP.
TYP.
T-1
T-2
22.002
TYP.
10.010
10.009
10.009
TYP.
TYP.
TYP.
ADA
ADA
ADA
AA-201
AA-201 2
AA-201
AA-2013
AA-301
3' - 0"
AA-4024
AA-4022
TYPICAL FLOOR JOINT
(SHOWN DASHED)
G.3
TYP.
G.1
TYP.
G.2
FD FD
FDFD
AA-301
T Y
P
/2
T Y
P
5' - 6" 3' - 0" 3' - 0" 3' - 0"
T Y
P
3' - 0"5' - 6" 3' - 0"
T Y
P
CL
22.025
22.028
BELOW7 3/4"
2' - 2"
/2
26.023
26.006
26.022
3.008
23.010
TYP.
22.008
22.009
22.014
10.004
10.004
30' - 0"
UNO
32.013 32.014
32.013
32.013
32.014
32.014
AA-301
T-9T-9
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:05 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-101
O V
E R
A L
L F
L O
O R
P L A
N
1/2" = 1'-0"1
OVERALL FLOOR PLAN
GENERAL NOTES
1. REFER TO AA-002 FOR GENERAL NOTES NOT FOUND ON
THIS SHEET.
2. REFER TO AA-601 FOR DOOR TYPES, SCHEDULE AND
DETAILS.
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.008 CONCRETE EQUIPMENT PAD, TYP.
10.004 ROOM SIGNAGE
10.009 TOILET PARTITIONS
10.010 URINAL PARTITIONS
22.002 LAVATORY AT ADA HEIGHT - REFER TO
PLUMBING
22.006 URINAL AT ADA HEIGHT - REFER TO
PLUMBING
22.007 URINAL - REFER TO PLUMBING
22.008 WATER CLOSET AT ADA HEIGHT -
REFER TO PLUMBING
22.009 WATER CLOSET - REFER TO PLUMBING
22.013 DRINKING FOUNTAIN - REFER TO
PLUMBING
22.014 SERVICE SINK - REFER TO PLUBMING
22.025 WATER HEATER - REFER TO PLUMBING
22.028 WALL HYDRANT - REFER TO PLUMBING
23.010 CONDENSING UNIT - REFER TO
MECHANICAL
26.006 ELECTRICAL PANEL - REFER TO
ELECTRICAL
26.022 CONTROL PANEL - REFER TO
ELECTRICAL
26.023 DISCONNECT SWITCH - REFER TO
ELECTRICAL
32.013 GUARDRAIL - REFER TO CIVIL PLANS
32.014 CONCRETE SIDEWALK AND STAIRS -
REFER TO CIVIL PLANS
G.1 30" X 48" CLEAR FLOOR SPACE PER
FLORIDA ACCESSIBILITY CODE 2020
SECTION 305.3
G.2 56" X 60" CLEAR FLOOR SPACE PER
FLORIDA ACCESSIBILITY CODE 2020
SECTION 604.3.1
G.3 60" DIAMETER TURNING SPACE PER
FLORIDA ACCESSIBILITY CODE 2020
SECTION 304.3.1
T-1 STAINLESS STEEL FRAMELESS MIRROR
T-2 WALL-MOUNTED SOAP DISPENSER
T-3 WALL-MOUNTED HAND DRYER
T-4 42" GRAB BAR
T-5 36" GRAB BAR
T-6 SURFACE-MOUNTED JUMBO ROLL
TOILET TISSUE DISPENSER
T-7 WALL-MOUNTED WASTE RECEPTACLE
T-9 18" VERTICAL GRAB BAR
MEN'S
CHASE
WOMEN'S
STORAGE
OFFICE
AA-301
AA-301
3"
TYP.
ALL SIDES
26.001
TYP.
23.004
23.013
8' - 10 1/4"VARIES
8' - 10 1/4"VARIES
8' - 10 1/4"
8' - 10 1/4"
8' - 10 1/4"
VARIES
VARIES
VARIES
3.019
TYP.
S T
R U
C T
U R
L
O
P E
S T
R U
C T
U R
O
P E
TYPICAL FLOOR JOINT
(SHOWN DASHED) SEAL
WATER/WEATHER TIGHT
AA-301
RCP LEGEND
NOTE: RCP DIMS ARE FROM FINISH FACE OF WALL
SOLATUBE 160 DS 10" SKYLIGHT OR EQUAL
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:06 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-103
O V
E R
A L
L R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
1/2" = 1'-0"1
OVERALL REFLECTED CEILING PLAN
GENERAL NOTES
1. REFER TO AA-002 FOR GENERAL NOTES NOT FOUND ON THIS
SHEET.
2. REFER TO AA-601 FOR DOOR TYPES, SCHEDULE AND
DETAILS.
3. REFER TO ELECTRICAL PLAN SHEET AE-101 FOR
ILLUMINATION LEVEL INFORMATION.
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.019 LINE OF PRE-CAST ROOF AND BEAMS -
TO BE PROVIDED BY PRE-ENGINEERED
BUILDING MANUFACTURER
23.004 AHU - REFER TO MECHANICAL
23.013 DUCTWORK - REFER TO MECHANICAL
26.001 EXTERIOR LED WALL PACK - REFER TO
ELECTRICAL
O
P E
S L O
P E
LINE OF EXTERIOR WALL BELOW
(SHOWN DASHED)
9' - 0"
CL
CL
CL
/8
WALL MOUNTED EXTERIOR
WALL PACK, REFER TO
ELECTRICAL, TYP. BELOW
SKYLIGHT, TYP.
TYPICAL FLOOR JOINT
(SHOWN DASHED) SEAL
WATER/WEATHER TIGHT
TYP.
1' - 0"
C L
PREFINISHED
METAL GUTTER
AND DOWNSPOUT,
TYP.
AA-104
AA-104
AA-104
AA-104
7.129
7.130
7.131
7.132
7.133
7.134
7.136
7.135
7.137
M
IN
3.072
MIN.
4"
NOTE: REFER TO MECHANICAL PLANS FOR LOCATIONS
MIN.
4"
7.138
7.146
7.144
7.145
7.142
7.135
7.141
7.137
3.072
7.143
7.154
7.155
7.156
7.157
7.140
7.153
7.158
7.135
7.141
7.137
3.072
7.137
7.141
7.135
3.072
7.140
7.135
7.141
7.137
3.072
7.147
7.148
7.138
7.152
4"
7.140
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:08 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-104
O V
E R
A L
L R
O O
F P
L A
N
1/2" = 1'-0"1
OVERALL ROOF PLAN
GENERAL NOTES
1. REFER TO AA-002 FOR GENERAL NOTES NOT FOUND ON THIS
SHEET.
2. SEE SHEET AA-002 FOR SYMBOLS LEGEND.
3. COORDINATE DIMENSIONAL REQUIREMENTS WITH ALL
EQUIPMENT AND BUILT-IN ITEMS PRIOR TO CONSTRUCTION.
4. ROOF PANELS ARE TO BE 5" THICK AND POST TENSIONED.
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION
NOT FOUND ON THIS SHEET.
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
3" = 1'-0"
ROOF PENETRATION DETAIL
3" = 1'-0"4
ROOF EDGE DETAIL WITH GUTTER
3" = 1'-0"5
SKYLIGHT DETAIL
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.072 PRECAST STRUCTURE
7.129 ROLL DOWN LED FLASHING 1" MIN.
DOWN INTO PIPE
7.130 PLUMBING VENT STACK
7.131 RUBBERIZED ASPHALT SEALANT
7.132 HPR MODIFIED MEMBRANE FLASHING
PLY 12" MIN. ON FIELD
7.133 BASE FLASHING PLY 8" MIN. ON FIELD
7.134 TORCH BASE SHEET
7.135 HPR TORCH MODIFIED MEMBRANE
7.136 SET LEAD FLANGE IN MASTIC, PRIME
FLANGE BEFORE STRIPPING
7.137 INSULATION, STAGGER ALL JOINTS,
FASTEN PER SPECIFICATION
7.138 CONTINUOUS CLEAT FASTENED 6" O.C.
7.140 HPR MODIFIED MEMBRANE FLASHING
PLY 9" MIN. ON FIELD
7.141 TORCH BASE SHEET
7.142 GUTTER FASTENED 6" O.C.
7.143 EXTEND ONE PLY OVER BLOCKING
7.144 GUTTER STRAP
7.145 GUTTER BRACKET
7.146 RUBBERIZED ASPHALT SEALANT
7.147 FASCIA COVER
7.148 CONCEALED SPLICE PLATE BETWEEN
10' SECTIONS
7.152 EXTEND PLY OVER BLOCKING FASTEN
8" O.C.
7.153 BASE FLASHING PLY 6" MIN. ON FIELD
7.154 SKYLIGHT
7.155 EXTRUDED ALUM FRAME WITH WEEP
HOLES
7.156 2"X10" MINIMUM
7.157 METAL CONTERFLASHING FASTENED 8"
O.C. WITH NEOPRENE WASHERS
7.158 CANT FASTENED TO NAILER
3" = 1'-0"6
ROOF APEX DETAIL
3" = 1'-0"3
ROOF EDGE DETAIL
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
T.O. REVEAL 1
3' - 4"
EF-2
EF-1
EF-3
22.013
PT-3
(BEYOND)
7.001
CL CL
CL
23.001
TYP.
T.O. REVEAL 2
3' - 10"
/8
5' - 0"10' - 0"
8.020
CL
CL
26.001
TYP.
26.001
AA-301
CENTER OF DOOR
ALIGN LIGHT WITH
10.004
TYPICAL PRECASTJOINT
(SHOWN DASHED) SEAL
WATER/WEATHER TIGHT
AA-201
7.073
7.038
TYP.
TYP.
MODULE 3
10' - 0"
MODULE 2
10' - 0"
MODULE 1
10' - 0"
PT-4
PT-4
7.039
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
103B
1:12 MIN. SLOPE
AA-301
T.O. REVEAL 1
3' - 4"
1:12 MIN. SLOPE
PT-3
EF-2
EF-3
EF-1
7.001
T.O. REVEAL 2
3' - 10"
26.001
TYP.
26.001
CL
CL
CENTER OF DOOR
ALIGN LIGHT WITH
AA-201
7.039 TYP.
7.039 TYP.
AA-301
PT-4
7.073
PT-4
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
T.O. REVEAL 1
3' - 4"
T.O. REVEAL 2
3' - 10"
CL
/8
10' - 0"4' - 11 5/8"
CL
7.001
EF-2
EF-3
EF-1
PT-323.001
TYP.
8.020
22.013
26.001
TYP.
26.001
AA-301
CL
CL
CENTER OF DOOR
ALIGN LIGHT WITH
10.004
TYPICAL PRECAST JOINT
(SHOWN DASHED) SEAL
WATER/WEATHER TIGHT
AA-201
7.039 TYP.
7.038 TYP.
MODULE 1
10' - 0"
MODULE 2
10' - 0"
MODULE 3
10' - 0"
PT-4
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
101 102
1:12 MIN. SLOPE
AA-301
T.O. REVEAL 1
3' - 4"
1:12 MIN. SLOPE
PT-3
22.013 10.003 PT-3
7.001
EF-2
EF-3
EF-1
CL CL
CENTER OF DOOR
ALIGN LIGHT WITH 4' - 1" 8' - 2"
T.O. REVEAL 2
3' - 10"
26.001
TYP.
23.001
TYP.
26.001
CL
CL
22.028
CENTER OF DOOR
ALIGN LIGHT WITH
10.003
AA-201
7.039 TYP.
7.038 TYP.
AA-301
PT-4
EXTERIOR FINISH MATERIALS
MANUFACTURER:
FINISH TYPE:
PRIMER:
PAINT:
COLOR:
NOTES:
EASI-SET BUILDINGS
EASI-BRICK
SHERWIN-WILLIAMS, LOXON CONDITIONER/PRIMER
SHERWIN-WILLIAMS, SUPERPAINT
SW 3061 BRICK (VERIFY TO MATCH CONCESSION STAND)
TO BE INSTALLED AS SHOWN IN ELEVATION VIEWS. REFER
TO SPECIFICATION FOR ADDITIONAL INFORMATION.
EXTERIOR FINISH 1 (EF-1)
MANUFACTURER:
FINISH TYPE:
PRIMER:
PAINT:
COLOR:
NOTES:
EASI-SET BUILDINGS
STUCCO - MATCH ADJACENT EXISTING BUILDING PATTERN
SHERWIN-WILLIAMS, LOXON CONDITIONER/PRIMER
SHERWIN-WILLIAMS, SUPERPAINT
SW 9561 GUILD GREY
TO BE INSTALLED AS SHOWN IN ELEVATION VIEWS. REFER
TO SPECIFICATION FOR ADDITIONAL INFORMATION.
EXTERIOR FINISH 2 (EF-2)
MANUFACTURER:
FINISH TYPE:
PRIMER:
PAINT:
COLOR:
NOTES:
EASI-SET BUILDINGS
CONCRETE - MATCH ADJACENT EXISTING BUILDING PATTERN
SHERWIN-WILLIAMS, LOXON CONDITIONER/PRIMER
SHERWIN-WILLIAMS, SUPERPAINT
SW 0055 LIGHT FRENCH GREY
TO BE INSTALLED AS SHOWN IN ELEVATION VIEWS. REFER TO
SPECIFICATION FOR ADDITIONAL INFORMATION.
EXTERIOR FINISH 3 (EF-3)
MANUFACTURER:
TYPE:
SHEEN:
COLOR:
NOTES:
SHERWIN-WILLIAMS
ARCHITECTURAL EXTERIOR LATEX
SATIN
SW 9624 WINSOME GREY
PAINT FOR ALL BUILDING DOORS.
EXTERIOR PAINT (PT-3)
MANUFACTURER:
TYPE:
SHEEN:
COLOR:
NOTES:
SHERWIN-WILLIAMS
ARCHITECTURAL EXTERIOR LATEX
SATIN
SW 7659 GRIS
PAINT FOR ALL BUILDING DOORS.
EXTERIOR PAINT (PT-4)
F
IN
IS
H
F L O
O R
B O
T T
O M
O F
C E
IL
IN
G
TYP.
3/8"
E F
-1
E F
-3
E F
-2
T Y
P
/8
C L C L
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:09 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-201
E X
T E
R
IO
R E
L E
V A
T
IO
N S
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
7.001 POST-TENSIONED CONCRETE ROOF
PANEL, TYPICAL
7.038 PRE-FINISHED DOWNSPOUT
7.039 PRE-FINISHED METAL GUTTER
7.073 DRIP EDGE FASCIA
8.020 TUBULAR SKYLIGHT, TYPICAL -
PROVIDED AND INSTALLED BY
PRE-ENGINEERED BUILDING
MANUFACTURER
10.003 SIGNAGE
10.004 ROOM SIGNAGE
22.013 DRINKING FOUNTAIN - REFER TO
PLUMBING
22.028 WALL HYDRANT - REFER TO PLUMBING
23.001 BRICK VENT - REFER TO MECHANICAL
26.001 EXTERIOR LED WALL PACK - REFER TO
ELECTRICAL
EF-1 BRICK EXTERIOR FINISH - REFER TO
FINISH SCHEDULE
EF-2 STUCCO EXTERIOR FINISH - REFER TO
FINISH SCHEDULE
EF-3 CONCRETE EXTERIOR FINISH - REFER
TO FINISH SCHEDULE
PT-3 WATER BASED CONCRETE STAIN-
REFER TO FINISH SCHEDULE
PT-4 EXTERIOR LATEX PAINT - REFER TO
FINISH SCHEDULE
1/2" = 1'-0"1
SOUTH EXTERIOR ELEVATION
1/2" = 1'-0"2
WEST EXTERIOR ELEVATION
1/2" = 1'-0"4
NORTH EXTERIOR ELEVATION
1/2" = 1'-0"3
EAST EXTERIOR ELEVATION
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
3" = 1'-0"6
TYPICAL EXTERIOR FINISH DETAIL
0' 2" 4"
GRAPHIC SCALE
SCALE 3" = 1'-0"
ROOF BEARING
9' - 0"
T.O. REVEAL 1
3' - 4"
T.O. REVEAL 2
3' - 10"
AA-301
10.009
T-3
22.010
T-7
8.002
3.004
3.003
TYP.
TYP.
3.002
TYP.
AA-601
AA-601
AA-601
GRADE VARIES - REFER TO
CIVIL FOR GRADING PLAN
3.005
26.021
NOTE: THE CONCRETE FLOOR, THE STEM WALLS AND
FOOTINGS ARE FOR ILLUSTRATION PURPOSES ONLY. FLOR,
STEM WALLS, AND FOOTINGS ARE DELEGATED DESIGN BY
PRE-CAST MANUFACTURER. REFER TO SPECIFICATIONS.
22.018
TYPICAL FLOOR JOINT
(SHOWN DASHED) SEAL
WATER/WEATHER TIGHT
TYPICAL MODULAR PRECAST
JOINT BY MANUFACTURER.
SEAL WATER/WEATHER TIGHT
MEN'S
STORAGE
MODULE 1
10' - 0"
MODULE 2
10' - 0"
MODULE 3
10' - 0"
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
AA-301
T.O. REVEAL 1
3' - 4"
T.O. REVEAL 2
3' - 10"102
8.002
T-3
T-2
T-7
22.010
T-3
22.007
T-7
22.008
8.002
3.002
3.004
3.003
TYP.
TYP.
GRADE VARIES - REFER TO CIVIL
FOR GRADING PLAN
26.021
26.018
TYP. NOTE: THE CONCRETE FLOOR, THE STEM WALLS AND
FOOTINGS ARE FOR ILLUSTRATION PURPOSES ONLY.
FLOOR, STEM WALLS, AND FOOTINGS ARE DELEGATED
DESIGN BY PRE-CAST MANUFACTURER. REFER TO
SPECIFICATIONS.
TYP.
AA-104
AA-104
WOMEN'S
PLUMBING
CHASE
MEN'S
23.00323.003
7.093
3.020
PT-1
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
3.020
3.002
3.004
7.002
6.305
OFFICE
7.093
3.072
7.002
9.0419.0419.041
6.305
FRP-2
FRP-1
9.074
9.041
6.3056.305
6.305
EXTERIOR INTERIOR
7.050
6.305
7.029
7.002
3.072
7.159 7.029
NOTE: REFER TO MECHANICAL PLANS FOR PENETRATION LOCATIONS.
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:12 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-301
B U
IL
D
IN
G
S E
C T
IO
N
S
1/2" = 1'-0"1
BUILDING SECTION 1
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.002 6" CONCRETE SLAB - TO BE PROVIDED
BY PRE-ENGINEERED BUILDING
MANUFACTURER
3.003 CONCRETE FOOTING - TO BE
PROVIDED BY PRE-ENGINEERED
BUILDING MANUFACTURER
3.004 CONCRETE STEM WALL - TO BE
PROVIDED BY PRE-ENGINEERED
BUILDING MANUFACTURER
3.005 CONCRETE SIDEWALK - REFER TO CIVIL
3.020 UNDERSLAB VAPOR BARRIER
3.072 PRECAST STRUCTURE
6.305 5/8" PLYWOOD SHEATHING WITH FRP
REFER TO INTERIOR FINISH SCHEDULE
7.002 RIGID INSULATION WITH INTEGRAL
VAPOR BARRIER
7.029 BACKER ROD AND SEALANT
7.050 CONDUIT OR PIPE PENETRATION, SIZE
VARIES, REFER TO ELECTRICAL AND
MECHANICAL FOR LOCATIONS OF
PENETRATIONS
7.093 1/2" PRE-MOLDED FILLER
7.159 GALVANIZED WALL PENETRATION
SLEEVE
8.002 HOLLOW METAL DOORS AND FRAMES
9.041 METAL CHANNEL FURRING
9.074 CORNER TRIM
10.009 TOILET PARTITIONS
22.007 URINAL - REFER TO PLUMBING
22.008 WATER CLOSET AT ADA HEIGHT -
REFER TO PLUMBING
22.010 SINK AT ADA HEIGHT - REFER TO
PLUMBING
22.018 MOP SINK - REFER TO PLUMBING
23.003 EXHAUST FAN -REFER TO MECHANICAL
26.018 RECEPTACLE - REFER TO ELECTRICAL
26.021 SWITCH - REFER TO ELECTRICAL
FRP-1 FIBERGLASS REINFORCED PANELS -
SOFT BEIGE
FRP-2 FIBERGLASS REINFORCED PANELS -
WHITE
PT-1 LATEX PAINT - REFER TO FINISH
SCHEDULE
T-2 WALL-MOUNTED SOAP DISPENSER
T-3 WALL-MOUNTED HAND DRYER
T-7 WALL-MOUNTED WASTE RECEPTACLE
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
1/2" = 1'-0"2
BUILDING SECTION 2
GENERAL NOTES
1. REFER TO AA-002 FOR GENERAL NOTES NOT FOUND ON THIS
SHEET.
2. ALL CONDUIT AND PIPING SHALL RUN TIGHT TO WALLS AND
CEILINGS. CONDUIT AND PIPING SHALL BE GROUPED AND
RAN TOGETHER AS EFFICIENTLY AS POSSIBLE. CONTRACTOR
IS TO SUBMIT PROPOSED CONDUIT AND PIPING RUNS TO
ENGINEER/OWNER FOR REVIEW AND APPROVAL PRIOR TO
INSTALLATION.
1/2" = 1'-0"3
WALL SECTION @ OFFICE
3" = 1'-0"5
WALL PENETRATION DETAIL
M
IN
M
A X
PAPER TOWEL
DISPENSER
RECEPTACLE SOAP
DISPENSER
(LIQUID)
WATER CLOSET/
GRAB BAR/TOILET
PAPER DISPENSER
WATER CLOSET/
GRAB BAR
LAVATORY/MIRROR
LINE OF WALL
MAX.
12" 42"
7"-9"
CL
M
IN
M
A X
36"
LINE OF WALL
6"
16"-18"CL
M
A X
M A
X
M A
X
M A
X
M A
X
M
IN
6" MAX
M
IN
11" MIN.
FINISH
FACE
OF WALL
M A
X
ELECTRIC HAND DRYER
FINISH
FACE
OF WALL
UTILITY SHELF
18"
M A
X
MIRROR DRINKING FOUNTAIN
M
IN
M A
X
M
IN
17"-19"
MIN.
8"
MAX.
6"
M A
X
SURFACE-MOUNTED WASTE
RECEPTACLE
M
IN
M
A X
M
IN
M
A X
/2
M
IN
M
IN
M
A X
TOILET ROOM ACCESSORIES SCHEDULE MANUF. MODEL# DESCRIPTION
T-1 STAINLESS STEEL MIRROR 17-1/2" X 23-1/2" FRAMELESS MIRROR
T-2 SOAP DISPENSER WALL-MOUNTED
T-4 GRAB BAR 42" B-5806.99 x 42
STAINLESS STEEL HORIZONTAL 42"
GRAB BAR WITH SNAP FLANGE
T-5 GRAB BAR 36" B-5806.99 x 36
T-6 TWIN JUMBO-ROLL TOILET TISSUE
DISPENSER
SURFACE-MOUNTED
STAINLESS STEEL HORIZONTAL 36"
GRAB BAR WITH SNAP FLANGE
BOBRICK
BOBRICK
B-2892
B-2112
B-1556
BOBRICK
BOBRICK
T-3 HAND DRYER WALL-MOUNTEDXLERATOR
BOBRICK
GENERAL ACCESSORY NOTES:
1. FIXTURES SHOWN ON THIS SHEET ARE FOR MOUNTING PURPOSES ONLY. REFER TO PLUMBING DRAWINGS FOR FIXTURE TYPES.
2. COORDINATE PLUMBING FIXTURES, WATER SUPPLY, SANITARY AND FLOOR DRAINS WITH PLUMBING PLANS & SPECIFICATIONS, TYPICAL.
3. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
4. REFER TO SHEET AA-401 FOR ACCESSORY MOUNTING HEIGHTS.
T-7 WALL-MOUNTEDB-279BOBRICKWASTE RECEPTACLE
XL-SB
T-8 SURFACE-MOUNTEDB-270BOBRICKSANITARY NAPKIN DISPOSAL
T-9 GRAB BAR 18" B-5806.99 x 18
STAINLESS STEEL VERTICAL 18"
GRAB BAR WITH SNAP FLANGE
BOBRICK
T-10 MOP AND BROOM HOLDERS AND HOOKS B-239 x 34
CLASSIC SERIES SHELF WITH MOP
AND BROOM HOLDERS AND HOOKS
BOBRICK
TYPICAL ACCESSIBILITY SIGNAGE LOCATION
CENTER OF
DOOR
SIGNAGE ON
LATCH SIDE OF
DOOR
CLEAR FLOOR SPACE
1' - 6" MIN.
SIGN CENTERED
ON TACTILE
CHARACTERS
1' - 6"
ACCESSIBILITY SIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
ACCESSIBILITY CODE 2020; CHAPTER 7; SECTION 703: SIGNS.
1) LOCATE SIGN AT SINGLE DOORS
ALONGSIDE THE DOOR AT THE LATCH
SIDE.
2) LOCATE SIGN AT DOUBLE DOORS
WITH ONE ACTIVE LEAF ON THE
INACTIVE LEAF SIDE.
3) LOCATE SIGN AT DOUBLE DOORS
WITH TWO ACTIVE LEAFS TO THE RIGHT
OF THE RIGHT HAND DOOR.
9" 9"
CL
ROOM NAME
SIGNAGE ON
LATCH SIDE
OF DOOR
RASTERIZED
BRAILLE
T A
C T
IL
E
C H
A R
A C
T E
R L
O C
A T
IO
N
H E
IG
H
T
ROOM NAME, BRAILLE AND
SYMBOLS TO BE STANDARD
WHITE AND CENTERED ON
PANEL. SYMBOLS, TEXT
AND BRAILLE TO BE RAISED
1/32"
9"
/8
/4
/8
1/16" THICK PANEL TO BE
STANDARD BLACK
ROOM NAME, BRAILLE AND
SYMBOLS TO BE STANDARD
WHITE AND CENTERED ON
PANEL. SYMBOLS, TEXT AND
BRAILLE TO BE RAISED 1/32"
9"
/8
/4
/8
1/16" THICK PANEL TO BE
STANDARD BLACK
ROOM NAME, BRAILLE AND
SYMBOLS TO BE STANDARD
WHITE AND CENTERED ON
PANEL. SYMBOLS, TEXT
AND BRAILLE TO BE RAISED
1/32"
/4
/4
/2
/4
1/16" THICK PANEL TO BE
STANDARD BLACK
8"
/2
"NO ADMITTANCE" SIGN
ROOM NAME, BRAILLE AND
SYMBOLS TO BE STANDARD
WHITE AND CENTERED ON
PANEL. SYMBOLS, TEXT
AND BRAILLE TO BE RAISED
1/32"
/4
/4
/2
/4
" 1/16" THICK PANEL TO BE
STANDARD BLACK2
8"
/2
"NO ADMITTANCE" SIGN
ROOM NAME, BRAILLE AND
SYMBOLS TO BE STANDARD
WHITE AND CENTERED ON
PANEL. SYMBOLS, TEXT
AND BRAILLE TO BE RAISED
1/32"
1/16" THICK PANEL TO BE
STANDARD BLACK
/4
8"
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:14 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-401
R E
S T
R O
O M
A C
C E
S S
IB
L E
D E
T A
IL
S
A
C C
E S
S O
R
IE
S A
N D
S
IG
N A
G E
D E
T A
IL
S
3/8" = 1'-0"3
TYPICAL FIXTURE MOUNTING HEIGHTS
3/8" = 1'-0"1
TOILET CLEARANCES
3/8" = 1'-0"2
LAVATORY CLEARANCES
1" = 1'-0"
ACCESSIBILITY SIGNAGE STANDARDS
SIGN SCHEDULE
DOOR NO. ROOM NAME SIGN
101 MEN'S MEN'S RESTROOM SIGN (A/AA-401)
102 WOMEN'S WOMEN'S RESTROOM SIGN (B/AA-401)
103 OFFICE OFFICE SIGN (C/AA-401), NO ADMITTANCE SIGN (E/AA-401)
103B PLUMBING CHASE NO ADMITTANCE SIGN (E/AA-401)
104 STORAGE STORAGE SIGN (D/AA-401), NO ADMITTANCE SIGN (E/AA-401)
3" = 1'-0"
MENS RR SIGN
3" = 1'-0"
WOMENS RR SIGN
A B
3" = 1'-0"
OFFICE SIGN
C D 3" = 1'-0"
STORAGE SIGN
3" = 1'-0"
NO ADMITTANCE SIGN
E
ROOF BEARING
9' - 0"
T-1
T-3
T-7
22.002
T-2
T-4
T-6
T-8
T-5
22.008
PT-1
22.035
AA-104
AA-301
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
T-3
T-1
T-2
22.002
T-7
10.00910.009
T-1
T-3
22.002
22.035
10.00910.009
TYP.
TYP.
TYP.
T-5
22.008
AA-301
ADA WATER
CLOSET
3.019
TYP.
22.009
T-6
T-8
PT-1
22.035
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
T-1
T-3
22.002
T-2
T-7
T-4
T-6
T-5
22.008
22.035
FIN. FLR.
0' - 0"
ROOF BEARING
9' - 0"
T-5
22.008
T-4
T-6
TYP.
10.00910.009
TYP.
ADA URINAL
22.006
10.010
22.007
TYP.
T-2
T-1
T-3
T-7
22.002
22.009
AA-301
ADA WATER
CLOSET
3.019
TYP.
PT-1
22.035
T-9
T-9
6" 6"
M
IN
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:16 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-402
IN
T
E R
IO
R
E L
E V
A T
IO
N
S
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.019 LINE OF PRE-CAST ROOF AND BEAMS -
TO BE PROVIDED BY PRE-ENGINEERED
BUILDING MANUFACTURER
10.009 TOILET PARTITIONS
10.010 URINAL PARTITIONS
22.002 LAVATORY AT ADA HEIGHT - REFER TO
PLUMBING
22.006 URINAL AT ADA HEIGHT - REFER TO
PLUMBING
22.007 URINAL - REFER TO PLUMBING
22.008 WATER CLOSET AT ADA HEIGHT -
REFER TO PLUMBING
22.009 WATER CLOSET - REFER TO PLUMBING
22.035 SCALD PROTECTION - REFER TO
SPECIFICATIONS
PT-1 LATEX PAINT - REFER TO FINISH
SCHEDULE
T-1 STAINLESS STEEL FRAMELESS MIRROR
T-2 WALL-MOUNTED SOAP DISPENSER
T-3 WALL-MOUNTED HAND DRYER
T-4 42" GRAB BAR
T-5 36" GRAB BAR
T-6 SURFACE-MOUNTED JUMBO ROLL
TOILET TISSUE DISPENSER
T-7 WALL-MOUNTED WASTE RECEPTACLE
T-8 SURFACE-MOUNTED SANITARY NAPKIN
DISPOSAL
T-9 18" VERTICAL GRAB BAR
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
1/2" = 1'-0"2
WOMEN'S RESTROOM - INTERIOR ELEVATION
1/2" = 1'-0"1
WOMEN'S RESTROOM - INTERIOR ELEVATION
1/2" = 1'-0"4
MEN'S RESTROOM - INTERIOR ELEVATION
1/2" = 1'-0"3
MEN'S RESTROOM - INTERIOR ELEVATION
AA BB CC
A S
S C
H E
D U
L E
D
AS SCHEDULED
6"
T Y
P
A S
S C
H E
D U
L E
D
AS SCHEDULED
A S
S C
H E
D U
L E
D
EQ. EQ.
AS SCHEDULED
DD
A S
S C
H E
D U
L E
D
AS SCHEDULED
EQ. 1' - 6" EQ.
KICKPLATE, REFER TO
HARDWARE SPECS
KICKPLATE, REFER TO
HARDWARE SPECS
KICKPLATE, REFER TO
HARDWARE SPECS
LOUVER
1/4" LAMINATE GLASS,
TYP
6"
3.001
7.0557.055
8.005
8.011
3.001
7.055
7.055
8.005
8.011
EXTERIOR INTERIOR
3.005
7.093
7.029
3.002
8.045
8.013
8.011
8.005
(BEYOND)
M A
X
/2
M A
X
/4
FINISH MATERIALS
PAINT
PT-1
MANUFACTURER:
SERIES:
TYPE
COLOR:
FINISH:
NOTES:
SHERWIN-WILLIAMS
DURACRAFT
ACRYLIC LATEX
WHITE
SATIN
USED FOR THE INTERIOR WALLS
PT-2
MANUFACTURER:
SERIES:
TYPE
COLOR:
FINISH:
NOTES:
SHERWIN-WILLIAMS
DURACRAFT
ACRYLIC LATEX
WHITE
SATIN
USED FOR THE INTERIOR CEILINGS AND BEAMS
PT-3
MANUFACTURER:
SERIES:
TYPE
COLOR:
FINISH:
SEALER
NOTES:
SHERWIN-WILLIAMS
H&C COLORTOP WATER-BASED SOLID COLOR CONCRETE STAIN
WATER-BASED CONCRETE STAIN
#124 - SILVER GRAY
LOW LUSTER
H&C COLORTOP SOLVENT-BASED SOLID COLOR CONCRETE SEALER
USED FOR THE INTERIOR CONCRETE FLOORS
3.001
7.0557.055
8.005
8.011
6.305
7.002
FRP-1
3.001
7.055
7.055
8.005
8.011
7.002
6.305
FRP-1
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
A G
/S C
G K
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
4/16/2024 1:20:19 PM
C
U s e rs
\s c o rn w e ll\
D o c u m e n ts
\2 .0
.H
E a s tm o n te
P a rk
T ra in in g C e n te r_ s c o rn w e llG
X
Z .r v t
AA-601
D O
O R
S C
H E
D U
L E
F
IN
IS
H S
C H
E D
U L E
A
N D
D E
T A
IL
S
DOOR SCHEDULE
DOOR FRAME HARDWARE
SET REMARKSMARK TYPE WIDTH HEIGHT THICKNESS MATERIAL MATERIAL HEAD JAMB THRESHOLD
101 DD 3' - 0" 7' - 0" 1 3/4" HM HM 1/AA-601 2/AA-601 3/AA-601 3.0
102 DD 3' - 0" 7' - 0" 1 3/4" HM HM 1/AA-601 2/AA-601 3/AA-601 3.0
103 AA 3' - 0" 7' - 0" 1 3/4" HM HM 4/AA-601 5/AA-601 3/AA-601 1.0
103B BB 2' - 0" 7' - 0" 1 3/4" HM HM 1/AA-601 2/AA-601 3/AA-601 2.0
104 CC 6' - 0" 7' - 0" 1 3/4" HM HM 1/AA-601 2/AA-601 3/AA-601 4.0
1/2" = 1'-0"
DOOR TYPES
GENERAL NOTES
1. CAULK ALL JOINTS WHERE DOOR AND WINDOW
FRAMES COME IN CONTACT WITH ADJACENT WALL
FINISHES.
2. PROVIDE ACOUSTIC SEALS AT ALL DOORS EXCEPT
FOR JANITOR. PROVIDE JANITOR DOOR WITH
SILENCERS.
3. ALL DOOR FRAMES TO BE INSTALLED AT 4" FROM
FACE OF FINISHED PARTITION.
HARDWARE SETS:
SET: 1.0
DESCRIPTION: OFFICE
3 HINGE, FULL MORTISE, HVY WT T4A3386XNRP 4-1/2" X 4-1/2" US32D MK
1 DORMITORY LOCK AUR 8867FL 630 YA
1 MORTISE CYLINDER AS REQUIRED - MATCH EXISTING 626 BE
1 SURFACE CLOSER UNI3501 TBGN 689 YA
1 KICK PLATE K1050 8" LAR CSK BEV US32D RO
1 OFFSET SADDLE THRESHOLD 2727A PE
1 THRESHOLD 290ASSTOP PE
1 GASKET S88D PE
1 SWEEP 29326CNB PE
1 RAIN GUARD 346C 40" PE
NOTES: EXTERIOR DOORS SHALL MEET FBC STANDARDS FOR WINDSTORM. THE HARDWARE SPECIFIED IS LISTED AS A BASIS OF DESIGN. IF ALTERNATE HARDWARE IS PROPOSED, PLEASE PROVIDE THIRD-PARTY TEST RESULTS AND COMPLIANCE INFORMATION TO
ARCHITECT. FLORIDA APPROVAL # FL16353.
SET: 2.0
DESCRIPTION: PLUMBING CHASE
3 HINGE, FULL MORTISE T4A2314XNRP 4-1/2" X 4-1/2" US32D MK
1 STOREROOM DEADBOLT LOCK AUR 8840FL 630 YA
1 MORTISE CYLINDER AS REQUIRED - MATCH EXISTING 626 BE
1 SUR OVERHEAD STOP 9-X36 689 YA
1 KICK PLATE K1050 8" LAR CSK BEV US32D RO
1 OFFSET SADDLE THRESHOLD 2727A PE
1 THRESHOLD 290ASSTOP PE
1 GASKET S88D PE
1 SWEEP 29326CNB PE
1 RAIN GUARD 346C 28" PE
NOTES: EXTERIOR DOORS SHALL MEET FBC STANDARDS FOR WINDSTORM. THE HARDWARE SPECIFIED IS LISTED AS A BASIS OF DESIGN. IF ALTERNATE HARDWARE IS PROPOSED, PLEASE PROVIDE THIRD-PARTY TEST RESULTS AND COMPLIANCE INFORMATION TO
ARCHITECT. FLORIDA APPROVAL # FL16353.
SET: 3.0
DESCRIPTION: RESTROOM
3 HINGE, FULL MORTISE, HVY WT T4A3386XNRP 4-1/2" X 4-1/2" US32D MK
1 DORMITORY LOCK AUR 8818-2FL 630 YA
1 MAGNETIC LOCK M680EBDX *** 630 SU
2 MORTISE CYLINDER AS REQUIRED - MATCH EXISTING 626 BE
1 SURFACE CLOSER UNI3501 TBGN 689 YA
1 KICK PLATE K1050 8" LAR CSK BEV US32D RO
1 OFFSET SADDLE THRESHOLD 2727A PE
1 THRESHOLD 290ASSTOP PE
1 GASKET S88D PE
1 SWEEP 29326CNB PE
1 RAIN GUARD 346C 40" PE
1 TIMER DT-7 *** SU
1 POWER SUPPLY BPS-24-1 *** SU
NOTES: EXTERIOR DOORS SHALL MEET FBC STANDARDS FOR WINDSTORM. THE HARDWARE SPECIFIED IS LISTED AS A BASIS OF DESIGN. IF ALTERNATE HARDWARE IS PROPOSED, PLEASE PROVIDE THIRD-PARTY TEST RESULTS AND COMPLIANCE INFORMATION TO
ARCHITECT. FLORIDA APPROVAL # FL16353.
*** PROVIDE AS ALTERNATE BID
SET: 4.0
DESCRIPTION: STORAGE PAIR
6 HINGE, FULL MORTISE, HVY WT T4A3386XNRP 4-1/2" X 4-1/2" US32D MK
2 FLUSH BOLT 556WS US26D RO
1 STOREROOM DEADBOLT LOCK AUR 8840 630 YA
2 MORTISE CYLINDER AS REQUIRED - MATCH EXISTING 626 BE
1 SUR OVERHEAD STOP 9-X36 689 YA
1 KICK PLATE K1050 8" LAR CSK BEV US32D RO
1 OFFSET SADDLE THRESHOLD 2727A PE
1 THRESHOLD 290ASSTOP PE
1 GASKET S88D PE
1 SWEEP 29326CNB PE
1 RAIN GUARD 346C 76" PE
NOTES: EXTERIOR DOORS SHALL MEET FBC STANDARDS FOR WINDSTORM. THE HARDWARE SPECIFIED IS LISTED AS A BASIS OF DESIGN. IF ALTERNATE HARDWARE IS PROPOSED, PLEASE PROVIDE THIRD-PARTY TEST RESULTS AND COMPLIANCE INFORMATION TO
ARCHITECT. FLORIDA APPROVAL # FL16353.
ASTRAGAL TO BE INCLUDED BY DOOR MANUFACTURER.
DOOR REMARKS
1. PROVIDE 1/4" CLEAR LAMINATED GLASS SIDE VISION
PANEL.
2. PROVIDE LED OCCUPANCY LIGHT ABOVE DOOR.
REFER TO ELECTRICAL, TYPICAL.
3. PROVIDE 18" X 18" FIXED LOUVER GRILL. REFER TO
DOOR ELEVATIONS.
4. HARDWARE SETS SHALL BE CHROME FINISH.
3" = 1'-0"1
TYPICAL EXTERIOR DOOR HEAD DETAIL
3" = 1'-0"2
TYPICAL EXTERIOR DOOR JAMB DETAIL
REFERENCE KEYNOTES
DIVISION AND
KEYNOTE NO. DESCRIPTION
3.001 4" PRECAST CONCRETE WALL
PANEL
3.002 6" CONCRETE SLAB - TO BE
PROVIDED BY PRE-ENGINEERED
BUILDING MANUFACTURER
3.005 CONCRETE SIDEWALK - REFER
TO CIVIL
6.305 5/8" PLYWOOD SHEATHING WITH
FRP REFER TO INTERIOR FINISH
SCHEDULE
7.002 RIGID INSULATION WITH
INTEGRAL VAPOR BARRIER
7.029 BACKER ROD AND SEALANT
7.055 CONTINUIOUS BEAD OF SEALANT
7.093 1/2" PRE-MOLDED FILLER
8.005 HOLLOW METAL FRAME
8.011 HOLLOW METAL DOOR
8.013 DOOR SWEEP
8.045 ALUMINUM THRESHOLD
FRP-1 FIBERGLASS REINFORCED
PANELS - SOFT BEIGE
3" = 1'-0"3
EXTERIOR DOOR THRESHOLD DETAIL
FINISH SCHEDULE
ROOM NUMBER ROOM NAME FLOOR FINISH WALL FINISH (ALL SIDES) CEILING FINISH REMARKS
101 MEN'S PT-3 PT-1 PT-2
102 WOMEN'S PT-3 PT-1 PT-2
103 OFFICE PT-3 FRP-1 FRP-2
104 STORAGE PT-3 PT-1 PT-2
105 PLUMBING CHASE PT-3 PT-1 PT-2
0' 2" 4"
GRAPHIC SCALE
SCALE 3" = 1'-0"
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
3" = 1'-0"4
TYPICAL EXTERIOR DOOR HEAD DETAIL @ FRP
3" = 1'-0"5
TYPICAL EXTERIOR DOOR JAMB DETAIL @ FRP
OFFICE
WOMEN'S
MEN'S
STORAGE
PLUMBING
CHASE
2 (TYP 4)
3 (TYP ALL)
3 (TYP ALL)
(TYP
ALL)
HB
(TYP
ALL)
SALAS O'BRIEN
GARY A. WILKERSON, P.E. 43167
KYLE J. CARTIER, P.E. 53269
JEFF A. KIRKMAN, P.E. 65629
ADAM S. LEVINE, P.E. 77010
21-04822 e x p e c t a d i f f e r e n c e
3501 Quadrangle Boulevard, Suite 100 Orlando, FL 32817
(407) 380-0400
CERT. OF AUTH. NO. 6106
VICTOR M. DIAZ, P.E. 55919
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
S O
F
V M
D
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
4/17/2024 11:59:28 AM
C
U s e rs
\t re s a .c ro c k e r\
D o c u m e n ts
\R e v it L o c a l F ile s \2
-0
M
E P
E a s tm o n te
P a rk
C e n tr a l F ile tr e s a .c ro c k e r.
rv t
AP-101
O V
E R
A L
L F
L O
O R
P L A
N
P L
U M
B
IN
G
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
GENERAL NOTES
1. REFER TO SPECIFICATION SECTION 130460 PREFABRICATED MODULAR BUILDING FOR
ADDITIONAL INFORMATION.
2. ALL PIPING SHALL BE INSTALLED TIGHT TO WALLS, CEILINGS, FLOORS, ETC. AND ALIGNED
WITH BUILDING STRUCTURE. THE PIPING RUNS SHALL BE INDICATED ON SHOP DRAWINGS
FOR REVIEW AND APPROVAL BEFORE INSTALLATION.
REFERENCE NOTES
PROVIDE NEW MINIMUM 20 GALLON TANK TYPE WATER HEATER IN THIS GENERAL LOCATION.
PROVIDE HOT WATER TO ALL SINKS AND LAVATORIES.
APPROXIMATE LOCATION OF 3-INCH DIAMETER FLOOR DRAIN. PROVIDE BLOCK OUT IN
CONCRETE SLAB TO ALLOW FOR CONNECTION TO UNDERGROUND SANITARY PIPING.
PROVIDE WALL MOUNTED WATER CLOSETS AND URINALS. PROVIDE WALL CARRIERS FOR
EACH PLUMBING FIXTURE LOCATED IN THE CHASE. WATER CLOSETS AND URINALS SHALL
UTILIZE MANUAL FLUSH VALVES.
PROVIDE 2-INCH WATER LINE INTO THE BUILDING IN THIS LOCATION. PROVIDE 2-INCH SHUT
OFF VALVE IN WATER LINE RISER AT 48 INCHES ABOVE FINISHED FLOOR. PROVIDE ACCESS
PANEL IN BUMP OUT FOR VALVE ACCESS.
PROVIDE 4-INCH SANITARY LINE LEAVING THE BUILDING IN THIS GENERAL LOCATION.
ALL PIPING IN THE CHASE SHALL BE ABOVE THE FLOOR WITH THE EXCEPTION OF THE
SANITARY PIPING LOCATED IN THE MIDDLE OF THE CHASE, WHICH SHALL BE UNDERGROUND.
PROVIDE FREEZE PROTECTED WALL HYDRANT IN THIS GENERAL LOCATION.
PROVIDE JANITOR’S MOP SINK IN THIS GENERAL LOCATION.
1/2" = 1'-0"AP-101
1 OVERALL FLOOR PLAN - PLUMBING
(2) #14 SMS AT EACH STRAP
END TO UNDERSIDE OF I-BEAM
1"x22 GA CONTINUOUS
STAINLESS STEEL STRAP
SHALL PASS OVER UNIT TO
I-BEAM ON OPPOSITE SIDE
(MIN 2 PER UNIT). STRAPS
SHALL BE SECURELY
TIGHTENED SNUG AGAINST
UNIT.
A/C HOUSING
(MIN 22 GA STEEL)
4"x1-1/2"x14 GA 6063-T6
ALUMINUM CLIP W/ (4) #14 SS TEK
SCREWS TO I-BEAM (MIN 4
ANGLES PER UNIT, 1 PER
CORNER)
A/C HOUSING
I-BEAM
(4) #14 TEKS PER ANGLE TO
MIN 22 GA STEEL HOUSING
-OR-
CONDENSING UNIT EQUIPMENT
STAND EQUIVALENT TO
PRECISION ALUMINUM PRODUCTS,
MODEL ALUMA STAND COASTAL
VERSION, MINIMUM 24 INCHES
HIGH AS MEASURED FROM THE
CONCRETE EQUIPMENT PAD TO
BOTTOM OF CONDENSING UNIT -
INSTALL IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS 2
M
IN
CONCRETE EQUIPMENT PAD
CONTRACTOR'S
CHOICE FOR
ATTACHMENT
NEOPRENE PAD AT ALL CONTACT POINTS
I-BEAM
ISOLATOR PADS BEYOND
(MIN 4 PER UNIT)
ISOLATOR PADS BEYOND
(MIN 4 PER UNIT)
INSTALL STAINLESS
STEEL HARDWARE
INTO CONCRETE PAD
PER MANUFACTURER'S
INSTRUCTIONS.
OFFICE
WOMEN'S
MEN'S
STORAGE
PLUMBING
CHASE
T 1
CD
R
SALAS O'BRIEN
GARY A. WILKERSON, P.E. 43167
KYLE J. CARTIER, P.E. 53269
JEFF A. KIRKMAN, P.E. 65629
ADAM S. LEVINE, P.E. 77010
21-04822 e x p e c t a d i f f e r e n c e
3501 Quadrangle Boulevard, Suite 100 Orlando, FL 32817
(407) 380-0400
CERT. OF AUTH. NO. 6106
VICTOR M. DIAZ, P.E. 55919
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
S O
F
V M
D
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
4/17/2024 11:59:27 AM
C
U s e rs
\t re s a .c ro c k e r\
D o c u m e n ts
\R e v it L o c a l F ile s \2
-0
M
E P
E a s tm o n te
P a rk
C e n tr a l F ile tr e s a .c ro c k e r.
rv t
AM-101
O V
E R
A L
L F
L O
O R
P L
A N
M
E C
H A
N
IC
A L
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
REFERENCE NOTES
PROVIDE CASSETTE TYPE CEILING MOUNTED SPLIT SYSTEM HEAT PUMP AIR HANDLING UNIT
IN CENTER OF ROOM. PROVIDE PROGRAMMABLE THERMOSTAT WITH WALL CRADLE ON
OFFICE ROOM WALL.
PROVIDE NEW SPLIT SYSTEM HEAT PUMP CONDENSING UNIT. PROVIDE 4-INCH THICK, 6-INCH
BORDER ALL AROUND CONCRETE EQUIPMENT PAD AND PLACE CONDENSING UNIT ON
EQUIPMENT STAND ON PAD. SECURE UNIT TO STAND AND STAND TO PAD TO WITHSTAND
HIGH WIND PRESSURES. REFER TO DETAIL THIS SHEET.
PROVIDE WALL MOUNTED LOUVER FOR OUTSIDE AIR INTAKE TO CEILING MOUNTED SPLIT
SYSTEM AIR HANDLING UNIT. PROVIDE 6-INCH DIAMETER GALVANIZED STEEL OUTSIDE AIR
DUCT FROM LOUVER TO CEILING MOUNTED AIR HANDLING UNIT. PROVIDE MOTORIZED
DAMPER IN OUTSIDE AIR DUCT THAT OPENS WHEN THE OUTDOOR CONDENSING UNIT
COMPRESSOR STARTS AND CLOSES WHEN THE OUTSIDE CONDENSING UNIT COMPRESSOR
STOPS.
PROVIDE REFRIGERANT AND CONDENSATE PIPING FROM CEILING MOUNTED SPLIT SYSTEM
AIR HANDLING UNIT TO GRADE MOUNTED CONDENSING UNIT AND TO GRADE. MOUNT PIPING
AS HIGH IN THE SPACE AS POSSIBLE TO MAXIMIZE HEADROOM. PROVIDE GALVANIZED STEEL
PIPE SHROUD ON OUTSIDE OF BUILDING TO HIDE PIPING. PRIME AND PAINT PIPE SHROUD TO
MATCH BUILDING COLOR. CONNECT REFRIGERANT PIPING FROM AIR HANDLING UNIT TO
CONDENSING UNIT AND MAKE UNIT FULLY OPERATIONAL. PROVIDE SCHEDULE 80 6-INCH PVC
PIPING SLEEVE UNDERGROUND FROM EDGE OF BUILDING TO CONDENSING UNIT FOR
REFRIGERANT PIPING ROUTING. DISCHARGE CONDENSATE TO GRASSY AREA AT GRADE.
PROVIDE 300 CFM IN-LINE EXHAUST FAN TO SERVE THE RESTROOM IN THIS GENERAL
LOCATION. MAKE-UP AIR FOR EXHAUST FAN SHALL BE THROUGH LOUVERS IN THE ENTRY
DOOR(S). PROVIDE GALVANIZED STEEL EXHAUST DUCTWORK SIZED FOR AN AIR VELOCITY
NO GREATER THAN 400 FEET PER MINUTE UP TO ROOF MOUNTED EXHAUST DISCHARGE.
DISCHARGE SHALL BE A GALVANIZED STEEL HOOD WITH ROOF CURB, WITH CURB EXTENDING
A MINIMUM OF 8 INCHES ABOVE THE ROOF DECK FOR FUTURE RE-ROOFING
CONSIDERATIONS. CONTROL FAN FROM LIGHTING CIRCUIT CONTROLLED BY OCCUPANCY
SENSOR.
1/2" = 1'-0"AM-101
1 OVERALL FLOOR PLAN - MECHANICAL
GENERAL NOTES
1. REFER TO SPECIFICATION SECTION 130460 PREFABRICATED MODULAR BUILDING FOR
ADDITIONAL INFORMATION.
2. ALL DUCTWORK AND PIPING SHALL BE INSTALLED TIGHT TO WALLS AND CEILINGS AND
ALIGNED WITH BUILDING STRUCTURE. THE PIPING RUNS SHALL BE INDICATED ON SHOP
DRAWINGS FOR REVIEW AND APPROVAL BEFORE INSTALLATION.
NOT TO SCALEAM-101
2 EQUIPMENT SUPPORT STAND
J J
J J
VS
VS
J
J
J
J
J
J
J
J
OFFICE
WOMEN'S
MEN'S
STORAGE
PLUMBING
CHASE
G
G
WP
WP
WP
WP
G
VS
VS
WP
SALAS O'BRIEN
GARY A. WILKERSON, P.E. 43167
KYLE J. CARTIER, P.E. 53269
JEFF A. KIRKMAN, P.E. 65629
ADAM S. LEVINE, P.E. 77010
21-04822 e x p e c t a d i f f e r e n c e
3501 Quadrangle Boulevard, Suite 100 Orlando, FL 32817
(407) 380-0400
CERT. OF AUTH. NO. 6106
VICTOR M. DIAZ, P.E. 55919
S C
A L E
1 2 3 4 5 6 7 8 9 10 11 12 13
A B
C D
E F
G H
J
E A
S T
M O
N T
E P
A R
K R
E S
T R
O O
M D
R A
W N
B Y
P R
O J E
C T
M N
G E
R
P R
O J
D A
T E
IS
S
U E
D F
O R
P
R E
L
IM
IN
A
R Y
R E V I S I O N S
S H E E T
N O
M
A G
N O
L
IA
D R
IV
E
A L
T A
M O
N T
E S
P R
IN
G
S
F L
O R
ID
A
N O
D
A T
E D
E S
C R
IP
T
IO
N
B Y
A S
N O
T E
D
S O
F
V M
D
.0
.H
/2
/2
P E
R M
IT
T
IN
G
B
ID
D
IN
G F
IN
A
L C
O N
S T
R U
C T
IO
N
C O
N S
T R
U C
T
IO
N R
E C
O R
D D
W G
BPE CA NO.: 00005898
BPA&ID CA NO.: AAC002023
651 WEST WARREN AVENUE,
STE 200
LONGWOOD, FLORIDA 32750
T 407.331.6116
WWW.BENTLEYGROUPINC.COM
4/17/2024 12:01:44 PM
C
U s e rs
\t re s a .c ro c k e r\
D o c u m e n ts
\R e v it L o c a l F ile s \2
-0
M
E P
E a s tm o n te
P a rk
C e n tr a l F ile tr e s a .c ro c k e r.
rv t
AE-101
O V
E R
A L
L F
L O
O R
P L A
N
E L
E C
T R
IC
A
L
0' 1' 2'
GRAPHIC SCALE
SCALE 1/2" = 1'-0"
GEN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .