Irrigation_Plans_.pdf

PDF 6 MB Posted

Attached to
90 North Park Irrigation
Solicitation number
2023-IFB-066
Issued by
Cook County, Illinois

About this file

The provided document is a comprehensive set of irrigation plans for the Schaumburg 90 NDW Urban Park project located in Schaumburg, Illinois, prepared by site design group, ltd. (Landscape Architect) and V3 Companies (Engineer). The plans include detailed irrigation system design across multiple sheets, covering enlargement areas such as the main irrigation plan, shared street irrigation, hammock grove, and two-wire schematic plans. The documents specify intricate irrigation infrastructure including mainline pipes, lateral pipes, valve boxes, controllers (Baseline BL-3200 and BL-Sub Station), rain gauges, soil moisture sensors, and two booster pump stations (Stations #1 and #2). The plans outline precise pipe sizing, valve locations, wire routing, and installation specifications for a comprehensive irrigation system spanning the urban park development.

The irrigation system design incorporates sophisticated technical elements like a two-wire decoder system, electric valves, backflow preventers, and detailed grounding requirements. The project includes multiple irrigation controllers (labeled C-1 and C-2) with specific mounting and installation instructions, and provisions for future expansion. The booster pump stations are detailed with specific power requirements, connection specifications, and concrete anchoring details. The plans demonstrate a high-level of engineering precision, including specifications for pipe sleeves, wire trenches, valve boxes, and comprehensive grounding schematics. The irrigation system is designed to support various landscape zones with different pipe sizes ranging from 1" to 15", and includes provisions for soil moisture sensing and rain gauge integration to optimize water usage efficiency.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2"

2"

3" 3"

3"

3"

3"

3"

3"

3"

3"3"

3"

2"

4"

3"

3"

4"

3"

2"

2"

2"

2"

1"

2"

2"

1"

1"

1"

2"

2"

2"

2"

1"

1"

2"

2"

2"

1"

2"

2"

1"

2"

2"

2"

1"

2"

2"

2"

1"

1"

2"

2"

2"

1"

2"

2"

2"

1"

2"

2"

2"

2"

1"

2"

2"

2"

2"

1"

2"

2"

2"

2"

1" 1"

2"

1"

2"

2"

1"2"

2"

1"

2"

2"

1"

1"

1"

2"

2"

2"

2"

1"

2"

1" 11 2"

1"

2"

2"

2"

1"

2"

2" 11 2"

2" 2"

2"

2"

2"

1"

2"

2"

2"

2"

1"

2"

2"

1"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

1"

1"

2"

2"

2"11

2"

2"

2"

2"

2"

2"

2"

2"

2" 2"

2"

2"

2"

2"

2"

2"

1"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

1" 1"

1"

2"

2"

2" 11

2"11 2"1"

2"

2"

2" 11

2" 1"

2"

2" 1" 1"

2"

2"

2"

2"

2"

2"

1"

2"

2"

2" 11 2"

2"

2"

2" 11 2"

1"

2"

2"

2"

2"

1"

2"

2"11

2"

2"

2"11 2"11

2"

1"

1"

1"

1"

1"1"

2"

1" 1"

2"

2"

2"

2"

1"

2"

2" 11

2"

1"

2"

2" 1"

1"

2"

1"

2"

2"

2"

1"

1" 1"

2"

2"

2"

2"

1"

1" 1"

1"

1"

2"

2"

2"11

2"

2"

2"

2"

1"

1"

1"

1" 1"

1"

1"

1"

1"

2"1"

2"

1"

1" 1"

1" 1"

1"

2"

2"

2"

2"

1"

1"

2"

1"

2"

2"

1"

1"

1"

1"

1"

1"

1"

1"

1"

1"

1" 11 2"

2"

2"

2"

2"

2"

2"

2"

1"

2"

2"

2"

2"

1"

1"

1"

2"

2"

2"

2"

2"

2"

1"

2"

2"

2"

2"

2"

2"

2"

1"

2"

1"

2"

1" 2"

2"

2"

2"

2-1 39112"

2-2 10.71"

2-3 28.3112"

2-4 34.6112"

2-5 51.5112"

2-6 18.91"

2-7 151"

2-8 36112"

2-9 42112"

2-10 26.5112"

2-11 31.4112"

2-12 36.6112"

2-13 36112"

2-14 30112"

2-15 36112"

2-16 28.5112"

2-17 31.5112"

2-18 42112"

2-19 36112" 2-20

36112"

2-21 36112"

2-22 28112"

2-24 27.4112"

2-25 38.0112"

2-26 34.4112"

2-27 11.51"

2-28 45.2112"

2-29 27.5112"

2-30 37.1112"

2-31 30112"

2-36 42112"

2-37 34.5112"

2-38 48112"

2-39 48112"

2-40 42112"

2-41 42112"

2-42 42112"

2-43 24.01"

2-44 42112"

2-45 30112"

2-46 36112"

2-47 42112"

2-48 10.51"

2-49 42112"

2-50 44.5112"

2-51 42112"

2-52 36112"

2-53 42112"

2-23 28.0112"

2-54 29.8112" 2-55

38.8112"

C-2

POC-2

BFPP2

Wx

B

A

736 735

734734

733 732

733734

8 73

PR

O G R

ESS PAR

KW

AY (TW

O W

AY)

PARK

SIDE

DRIV

E (TW

O WAY)

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

3.0

3.0

3.0

3.0

3.0

3.0

1.5

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0 6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

3.0

3.0

3.0

2.5

1.5

1.5

3.0

3.0

3.0

3.0

3.0

1.5

1.5 3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

2.5

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

6.0

6.0

6.0

6.06.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5 1.5

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

3.0

3.0

3.0

3.0 3.0

2.0

1.5

2.0

3.0

3.0

3.0 3.0

3.0 3.0

3.0

3.0

3.0

4.0

1.5

1.5

6.0 3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

3.0

3.0

3.0

1.5

1.5

3.0

3.0

2.5

1.5

2.0

3.0

3.0

3.0

3.0

3.0 3.0

3.0

3.0

2.0

1.5

K

K

B

B

B

B

B

B

B

B

B

B

B

B

R

R

1.5

3.0

3.0

3.0

3.0

2.0

3.0

3.0

1.53.03.03.03.03.01.5

1.5

1.5

3.0 3.0

3.0

3.0

6.0

3"sl

01 21

01 01

8 8

8 8

21 21

21 21

01 01

E

E

3"sl

6"/2"sl

51 51

51 51

51 51

51 51

5151 51

8 8

8 8

8 8

8 8

8 8

8 8

8 8 8

8 8

51 51

8 8

8 8

51 51

51 51

51 51

51 51

5151 51

51 51

51 51

51 51

3"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

3"sl

6"/2"sl

6" /2

"s l

6"/2"sl

3"sl

6"/2"sl

3"sl

4"sl

3"sl 3"sl

6"/2"sl

3" sl

3"sl

8" /2

"s l

8"/2"sl

4" sl

3" sl

6" /2

"s l

3"sl

4"sl

4"sl

3"sl 3"sl

4"sl

4"sl

3"sl

6"/2"sl

6"/2"sl

6"/2"sl

3"/1"sl

4"sl 4"sl

2000 30002000

POC-1

POC-2

1-X

2-X

Wx

LEGEND

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

5' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

8' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

10' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

12' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

15' Series

HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD

Full/Part Circle Nozzles, Noted

HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD

with HUNTER MP ROTATOR NOZZLE - AS NOTED

HUNTER I-20-PRB 6" ROTOR

Full/Part Circle - Nozzles As Noted

RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan

BUCKNER 34" QUICK COUPLER VALVE

Provide Owner with Valve Keys and Hose Swivels

(2) Keys; (2) Hose Swivels

ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe

Class 200 PVC Mainline Pipe - Size per Plan

HDPE DR 15 Lateral Pipe - Size per Plan

SLEEVE - (BORING REQUIRED) - Size per plan

SLEEVE - Size per Plan

POINT OF CONNECTION - 2"

Labeled as POC-1.

Design Pressure - 55 psig prior to RPZ.

POINT OF CONNECTION - 3"

Labeled as POC-2.

Design Pressure -55 psig prior to RPZ.

IRRIGATION CONTROLLER

Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-PLUS-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.

Install Bird Spikes on upper edge of gauge (4"Ø)

BASELINE SOIL MOISTURE SENSOR

IRRIGATION CONTROLLER - SUBSTATION

Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL

CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-SUBSTN-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

2" WINTERIZATION PORT on pump station discharge pipe.

IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)

PUMP 1 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64

205V 3 PHASE 60HZ - 18 FULL LOAD AMPS

50 GPM @ 25 PSI BOOST - See Pump Details

PUMP 2 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60

208V 3 PHASE 60HZ - 21 FULL LOAD AMPS

100 GPM @ 25 PSI BOOST - See Pump Details

4" / 2"sl Sleeve / Bore

Wire Sleeve Size Pipe Sleeve Size

Station Number Controller Number

351" 1-24

Zone GPM Valve Size

P2

P1

ES CS SSRCSLCS

Q H F

FHTQ

FHTQ

ES CS SSRCSLCS

E L R C S

4 6 8 01 21 51 71

1.5 2.0 2.5

3.0 4.0 5.0 6.0

BFP

Q T H TT TQ F

Q T H TT TQ F

K BR

SMS

LI-400

IRRIGATION PLAN

ENLARGEMENT A

SEE ENLARGEMENT - SHEET LI-410

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park

Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

IRRIGATION PLAN ENLARGEMENT A

1" = 30'-0"1

M

AT

C H L

IN

E

LI

-4

M

AT

C H L

IN

E

LI

-4

0 30 60'10 20 40 50

3"

3"

3"

2"

2"

2"

2"

2"

3"

3"

STUB MAINLINE FOR FUTURE

IRRIGATION SYSTEM EXPANSION

WITH DECODER WIRE. SEE

TWO-WIRE PLANS.

1"

1"

2"

2"

1"

1"

2"

2"

1"

1"

2"

2"

1"

2"

1"

1"

1"

1"

1"1"

2"

1"

2"

2"

2"

2"

2"

1"

2"

2"

2"

2"

2"11

2"

2"

1"

1"

2"

2"

2"

2"

2"

2" 11

2"

1"1"

1" 1"

2"

1"1"

2"

2"

1"11 2"

2"

1"

2"

1"

1"

2"

2"

2"

1"

2"

2"

2"

2"

1"

1"

2"

2"

2"

2"11

2"

2" 1"

2"

1"

2"

2"

2"

2" 1"

1"

1"

1"

2"

2"

2"

2"

2"2"

2"

1"1"

2"

2"

2"

1"11 2"

1"1"

1"

2" 2"

1" 1"

2"

1"

2"

2"

2"

2"

2"

2"

2"

2"

1-4 26.5112"

1-3 31.5112"

1-1 7.021"

1-10 40112"

1-11 30112"

1-13 24112"

1-12 36112"

1-9 33112"

1-8 42112"

1-2 42112"

1-5 32112"

1-6 30112"

1-14 36112"

1-7 29.5112"

2-32 36112"

2-33 30.5112"

2-34 42112"2-35

25.9112"

2-36

2-56 38.8112"

2-57 38.8112"

POC-1

C-1

BFPP1

Wx

732 732

PAR

KSID

E DR

IVE (

TWO W

AY)

LANDM

ARK DRIVE (TW

O W

AY)

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

1.5

2.0

2.03.0 3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

1.5

1.5 3.0

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0

1.5

3.0

2.0

6.0

6.0 6.0 6.0 6.0

6.06.06.06.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5 1.5

2.0 2.0

3.0

3.0

1.5 3.0

3.0

2.0

3.0 3.0

3.0

3.03.0 3.0

3.0

3.0 3.0

2.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

3.0

3.0

3.0

3.0

3.0

2.0

1.5

2.0

3.0

3.0

3.0

2.0

1.5

3.0

1.5

2.0

3.0

3.0

3.0

3.0

3.0

6.0

6.0

6.0

6.0 6.0

6.0

6.0

6.0

6.0

6.0 6.0

5.0 2.5

51 51

515 51

51 51

51 51

5151 51

5151 51 51

51 51

51 51

4"sl

3"sl

3"sl

4"sl

4"sl

3"sl

4" /2

"s l

3"sl

4"sl

3"sl

6" /2

"s l

3"sl

3"sl

4"/4"sl

2000 30002000

POC-1

POC-2

1-X

2-X

Wx

LEGEND

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

5' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

8' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

10' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

12' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

15' Series

HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD

Full/Part Circle Nozzles, Noted

HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD

with HUNTER MP ROTATOR NOZZLE - AS NOTED

HUNTER I-20-PRB 6" ROTOR

Full/Part Circle - Nozzles As Noted

RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan

BUCKNER 34" QUICK COUPLER VALVE

Provide Owner with Valve Keys and Hose Swivels

(2) Keys; (2) Hose Swivels

ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe

Class 200 PVC Mainline Pipe - Size per Plan

HDPE DR 15 Lateral Pipe - Size per Plan

SLEEVE - (BORING REQUIRED) - Size per plan

SLEEVE - Size per Plan

POINT OF CONNECTION - 2"

Labeled as POC-1.

Design Pressure - 55 psig prior to RPZ.

POINT OF CONNECTION - 3"

Labeled as POC-2.

Design Pressure -55 psig prior to RPZ.

IRRIGATION CONTROLLER

Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-PLUS-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.

Install Bird Spikes on upper edge of gauge (4"Ø)

BASELINE SOIL MOISTURE SENSOR

IRRIGATION CONTROLLER - SUBSTATION

Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL

CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-SUBSTN-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

2" WINTERIZATION PORT on pump station discharge pipe.

IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)

PUMP 1 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64

205V 3 PHASE 60HZ - 18 FULL LOAD AMPS

50 GPM @ 25 PSI BOOST - See Pump Details

PUMP 2 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60

208V 3 PHASE 60HZ - 21 FULL LOAD AMPS

100 GPM @ 25 PSI BOOST - See Pump Details

4" / 2"sl Sleeve / Bore

Wire Sleeve Size Pipe Sleeve Size

Station Number Controller Number

351" 1-24

Zone GPM Valve Size

P2

P1

ES CS SSRCSLCS

Q H F

FHTQ

FHTQ

ES CS SSRCSLCS

E L R C S

4 6 8 01 21 51 71

1.5 2.0 2.5

3.0 4.0 5.0 6.0

BFP

Q T H TT TQ F

Q T H TT TQ F

K BR

SMS

LI-401

IRRIGATION PLAN

ENLARGEMENT B

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park

Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

IRRIGATION PLAN ENLARGEMENT B

1" = 30'-0"1

0 30 60'10 20 40 50

M

AT

C H L

IN

E

LI

-4

M

AT

C H L

IN

E

LI

-4

M

AT

C H L

IN

E

LI

-4

M

AT

C H L

IN

E

LI

-4

2"

2"

2"

2"

2"

2"

1"

1"

2"

2"

2"

2"

2"

1"

2"

1"

2"

1"

2"

2"

2"

2" 11

2" 1"11 2"

1"

2" 11 2"

1"

1"

2"

2"

2"

1-16 31.5112"

1-15 31.5112"

1-17 39.5112"

1-18 33112"

1-19 151"

1-20 24.51"

729 728

AR

BO

R D R

IVE (TW

O W

AY)

PARKSIDE DRIVE (TWO WAY)

3.0 3.0

3.0 3.0 3.0 3.0 3.0 1.5

3.0

3.0

1.51.5

4.0

3.0 1.5

3.0

1.5

1.5

3.0

3.0

3.0

3.0

3.0

3.0 3.0

2.0 2.0

3.0

2.0

3.0

3.0

3.0

2.5

3.0 3.0 3.0 3.0 3.0

3.0 2.0

2.0

1.5

2.0

3.0 3.0

3.0

3.0

3.0

1.5

3.0

6.0 4.0

2.0

3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 1.5

1.5

2.0 2.0

2.02.02.03.03.0 3.0 3.0 3.0 3.03.0

3" sl

3" sl

4" /2

"s l

3" sl

2000 30002000

POC-1

POC-2

1-X

2-X

Wx

LEGEND

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

5' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

8' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

10' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

12' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

15' Series

HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD

Full/Part Circle Nozzles, Noted

HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD

with HUNTER MP ROTATOR NOZZLE - AS NOTED

HUNTER I-20-PRB 6" ROTOR

Full/Part Circle - Nozzles As Noted

RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan

BUCKNER 34" QUICK COUPLER VALVE

Provide Owner with Valve Keys and Hose Swivels

(2) Keys; (2) Hose Swivels

ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe

Class 200 PVC Mainline Pipe - Size per Plan

HDPE DR 15 Lateral Pipe - Size per Plan

SLEEVE - (BORING REQUIRED) - Size per plan

SLEEVE - Size per Plan

POINT OF CONNECTION - 2"

Labeled as POC-1.

Design Pressure - 55 psig prior to RPZ.

POINT OF CONNECTION - 3"

Labeled as POC-2.

Design Pressure -55 psig prior to RPZ.

IRRIGATION CONTROLLER

Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-PLUS-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.

Install Bird Spikes on upper edge of gauge (4"Ø)

BASELINE SOIL MOISTURE SENSOR

IRRIGATION CONTROLLER - SUBSTATION

Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL

CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-SUBSTN-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

2" WINTERIZATION PORT on pump station discharge pipe.

IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)

PUMP 1 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64

205V 3 PHASE 60HZ - 18 FULL LOAD AMPS

50 GPM @ 25 PSI BOOST - See Pump Details

PUMP 2 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60

208V 3 PHASE 60HZ - 21 FULL LOAD AMPS

100 GPM @ 25 PSI BOOST - See Pump Details

4" / 2"sl Sleeve / Bore

Wire Sleeve Size Pipe Sleeve Size

Station Number Controller Number

351" 1-24

Zone GPM Valve Size

P2

P1

ES CS SSRCSLCS

Q H F

FHTQ

FHTQ

ES CS SSRCSLCS

E L R C S

4 6 8 01 21 51 71

1.5 2.0 2.5

3.0 4.0 5.0 6.0

BFP

Q T H TT TQ F

Q T H TT TQ F

K BR

SMS

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

M

AT

C H L

IN

E

LI

-4

M

AT

C H L

IN

E

LI

-4

LI-402

IRRIGATION PLAN

ENLARGEMENT C

IRRIGATION PLAN ENLARGEMENT C

1" = 30'-0"1

2"

2"

2"

2"

2"

2"

2"11

2"

2"

2" 2" 2"2"

2"11 2"

2"

2"

2" 11

2" 1"

2"

2" 1" 1"

2"

111 " 1" 1"

2" 11

2"

1"

2"

2" 1"

1"

2"

1"

2"

2"

2"

1"

1" 1"

2"

2"

2"

2"

1"

1" 1"

1"

1"

1"

1"

1" 11 2"

2"

2"

2"

1"

2"

2"

2"

2"

2"

1"

2"

2-16 28.5112"

2-17 31.5112"

2-18 42112"

2-19 36112" 2-20

36112"

2-21 36112"

2-22 28112"

2-54 29.8112" 2-55

38.8112"

2-56

6.0

6.0 6.0

6.0

3.0

1.5 1.5

3.0

3.0 3.0

3.0 3.0

3.0

1.5

1.5

6.0 3.0

3"sl

01 01

8 8

8 8

21 21

21 21

01 01

3"sl

6"/2"sl

51 51

51 51

51 51

51 51

5151 51

8 8

8 8

8 8

8 8

8 8

8 8

8 8 8

8 8

51 51

8 8

8 8

51 51

51 51

51 51

51 51

5151 51

51 51

51 51

51 51

3"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

3"sl

6"/2"sl

6" /2

"s l

6"/2"sl

3"sl

6"/2"sl

3"sl

4"sl

3"sl 3"sl

6"/2"sl

4"sl

2000 30002000

POC-1

POC-2

1-X

2-X

Wx

LEGEND

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

5' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

8' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

10' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

12' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

15' Series

HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD

Full/Part Circle Nozzles, Noted

HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD

with HUNTER MP ROTATOR NOZZLE - AS NOTED

HUNTER I-20-PRB 6" ROTOR

Full/Part Circle - Nozzles As Noted

RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan

BUCKNER 34" QUICK COUPLER VALVE

Provide Owner with Valve Keys and Hose Swivels

(2) Keys; (2) Hose Swivels

ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe

Class 200 PVC Mainline Pipe - Size per Plan

HDPE DR 15 Lateral Pipe - Size per Plan

SLEEVE - (BORING REQUIRED) - Size per plan

SLEEVE - Size per Plan

POINT OF CONNECTION - 2"

Labeled as POC-1.

Design Pressure - 55 psig prior to RPZ.

POINT OF CONNECTION - 3"

Labeled as POC-2.

Design Pressure -55 psig prior to RPZ.

IRRIGATION CONTROLLER

Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-PLUS-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.

Install Bird Spikes on upper edge of gauge (4"Ø)

BASELINE SOIL MOISTURE SENSOR

IRRIGATION CONTROLLER - SUBSTATION

Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL

CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-SUBSTN-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

2" WINTERIZATION PORT on pump station discharge pipe.

IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)

PUMP 1 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64

205V 3 PHASE 60HZ - 18 FULL LOAD AMPS

50 GPM @ 25 PSI BOOST - See Pump Details

PUMP 2 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60

208V 3 PHASE 60HZ - 21 FULL LOAD AMPS

100 GPM @ 25 PSI BOOST - See Pump Details

4" / 2"sl Sleeve / Bore

Wire Sleeve Size Pipe Sleeve Size

Station Number Controller Number

351" 1-24

Zone GPM Valve Size

P2

P1

ES CS SSRCSLCS

Q H F

FHTQ

FHTQ

ES CS SSRCSLCS

E L R C S

4 6 8 01 21 51 71

1.5 2.0 2.5

3.0 4.0 5.0 6.0

BFP

Q T H TT TQ F

Q T H TT TQ F

K BR

2"

2"2"

2"

1"1"

2"

2"

2"

1"11 2"

1"1"

1"

2" 2"

1" 1"

2"

2"

2"

2"

2"

2-56 38.8112"

2-57 38.8112"

51 51

51 51

51 51

5151 51

5151 51 51

51 51

51 51

4"sl

3"sl

3"sl

4"sl

4"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

4"sl

3"sl

3"sl

4"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

3"sl

6"/2"sl

6" /2

"s l

6"/2"sl

3"sl

6"/2"sl

3"sl

4"sl

4"sl

3"sl 3"sl

6"/2"sl

4"sl

G

S2 G

G

SMS

Wx

LEGEND

TWO-WIRE PATH ROUTE

WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow

TWO-WIRE PATH ROUTE

WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red

SLEEVE - (BORING REQUIRED) - Size per Plan

SLEEVE - Size per Plan

PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE

PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE

MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN

OPEN SKY ON THE PUMP ENCLOSURE.

INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)

BASELINE SOIL MOISTURE SENSOR

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

LI-403

SHARED STREET IRRIGATION

IRRIGATION PLAN ENLARGEMENT SHARED STREET

1" = 30'-0"1

0 30 60'10 20 40 50

M

AT

C H L

IN

E

SE

E

BE

LO

W

M

AT

C H L

IN

E

SE

E

AB

O

VE

TWO-WIRE SCHEMATIC PLAN SHARED STREET

1" = 50'-0"1

0 50 100'

3"

3"

2"

2"

2"

2"

1"

2"

1"

2"

1"

1"

11 "

1"

2"

1"

1"

1"

2"

2"

1"

1"

1"

2"

2"

2"

2"

1"

2"

2"

2"11

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2" 11

2" 1"

2"

2" 1" 1"

2"

2"

2"

2"

2"

2"

1"

2"

2"

2"11 2"11

2"

1"

1"

1"

1"

1"1"

2"

1" 1"

2"

2"

2"

2"

1"

2"

2" 11

2"

1"

2"

2" 1"

1"

2"

2"

2"

2"

1"

2"

1"

2"

1"

1"

1"

1"

1"

1"

1"

1" 11 2"

2"

2"

2"

2"

2"

2"

2"

2"

1"

2"

1" 2"

2"

2"

2"

2-20 36112"

2-21 36112"

2-22 28112"

2-24 27.4112"

2-25 38.0112"

2-26 34.4112"

2-27 11.51"

2-28 45.2112"

2-29 27.5112"

2-30 37.1112"

2-52 36112"

2-53 42112"

2-23 28.0112"

2-54 29.8112" 2-55

38.8112"

736 735

734734

733 732

733734

8 73

3.0

3.0

3.0

3.0

3.0

3.0

3.0

1.5

3.0

3.0

3.0

3.0

3.0

3.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

3.0 3.0

3.0

3.0

3.0

4.0

1.5

6.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0

3.0 3.0

3.0

3.0

2.0

1.5

3"sl

01 21

01 01

8 8

8 8

21 21

21 21

01 01

E

E

3"sl

8 8

8 8

51 51

8 8

51 51

51 51

5151 51

51 51

51 51

51 51

3"sl

3"sl

6"/2"sl

6"/2"sl

3"sl

3"sl

3"sl

6"/2"sl

6" /2

"s l

3"sl

6"/2"sl

3"sl

4"sl

3"sl

6"/2"sl

6" /2

"s l

3"sl

4"sl

4"sl

3"sl 3"sl

6"/2"sl

6"/2"sl

3"/1"sl

2000 30002000

POC-1

POC-2

1-X

2-X

Wx

LEGEND

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

5' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

8' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

10' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

12' Series

HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD

15' Series

HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD

F Strip Series

HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD

Full/Part Circle Nozzles, Noted

HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD

with HUNTER MP ROTATOR NOZZLE - AS NOTED

HUNTER I-20-PRB 6" ROTOR

Full/Part Circle - Nozzles As Noted

RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan

BUCKNER 34" QUICK COUPLER VALVE

Provide Owner with Valve Keys and Hose Swivels

(2) Keys; (2) Hose Swivels

ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe

Class 200 PVC Mainline Pipe - Size per Plan

HDPE DR 15 Lateral Pipe - Size per Plan

SLEEVE - (BORING REQUIRED) - Size per plan

SLEEVE - Size per Plan

POINT OF CONNECTION - 2"

Labeled as POC-1.

Design Pressure - 55 psig prior to RPZ.

POINT OF CONNECTION - 3"

Labeled as POC-2.

Design Pressure -55 psig prior to RPZ.

IRRIGATION CONTROLLER

Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-PLUS-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.

Install Bird Spikes on upper edge of gauge (4"Ø)

BASELINE SOIL MOISTURE SENSOR

IRRIGATION CONTROLLER - SUBSTATION

Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL

CONTROLLER

W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ

W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL

#BL-BMW2-SUBSTN-5YR

Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.

2" WINTERIZATION PORT on pump station discharge pipe.

IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)

PUMP 1 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64

205V 3 PHASE 60HZ - 18 FULL LOAD AMPS

50 GPM @ 25 PSI BOOST - See Pump Details

PUMP 2 - WATERTRONICS BOOSTER PUMP STATION

WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60

208V 3 PHASE 60HZ - 21 FULL LOAD AMPS

100 GPM @ 25 PSI BOOST - See Pump Details

4" / 2"sl Sleeve / Bore

Wire Sleeve Size Pipe Sleeve Size

Station Number Controller Number

351" 1-24

Zone GPM Valve Size

P2

P1

ES CS SSRCSLCS

Q H F

FHTQ

FHTQ

ES CS SSRCSLCS

E L R C S

4 6 8 01 21 51 71

1.5 2.0 2.5

3.0 4.0 5.0 6.0

BFP

Q T H TT TQ F

Q T H TT TQ F

K BR

SMS

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

HAMMOCK GROVE IRRIGATION PLAN ENLARGEMENT

1" = 20'-0"1

0 10 20 30 40' LI-410

HAMMOCK GROVE IRRIGATION

PLAN ENLARGEMENT

LI-500

IRRIGATION DETAILS

ISOLATION VALVE - 2" and 3"

NTS6

PUSH-ON GATE VALVE - 4" and LARGER

NTS7

QUICK COUPLER VALVE

NTS2

12" SPRAY HEAD

NTS

4" SPRAY HEAD

NTS54

WIRE TRENCH

NTS14 ELECTRIC VALVE with biCoder

NTS15ELECTRIC VALVE

NTS13

SLEEVING

NTS3

DECODER CABLE FUSE DEVICE

NTS

GROUNDING SCHEMATIC

NTS11

SOIL SENSOR

NTS1

I-20 4" ROTOR - GENERAL TURF

NTS12

DIAGRAM - THRUST BLOCKS

NTS

DIAGRAM - IRRIGATION CONTROLLER MOUNTING

NTS8

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

FINISH GRADE

GROWING MEDIA

10" ROUND VALVE BOX

8" CORRUGATED PE PIPE

LENGTH AS REQD.

IRRIGATION LINE

UNDISTURBED SOIL

HDPE STIFFENERS and RESTRAINTS

CONTINUOUS TRACER WIRE

LEEMCO LGV-X00BB VALVE

(SIZE TO IRRIGATION PIPE)

MAINLINE TRACER WIRE

LOOP 3-FEET OF WIRE &

LABEL

FINISH GRADE

GROWING MEDIA

10" ROUND VALVE BOX

8" CORRUGATED PE PIPE

LENGTH AS REQD.

UNDISTURBED SOIL

JOINT RESTRAINTS

CONTINUOUS TRACER WIRE

MAINLINE TRACER WIRE

LOOP 3-FEET OF WIRE &

LABEL

CUT TILE TO

CREATE FLAPS

IRRIGATION LINE

LEEMCO LMV-BBHDSS GATE VALVE

WITH RESTRAINTS AND STIFFENERS

(SIZE TO IRRIGATION PIPE)

MAINLINE PIPE

FINISH GRADE OF GROWING MEDIA

10" ROUND VALVE BOX

FILL TOP PORTION OF VALVE BOX

WITH CLEAN 3/8" CHIP GRAVEL

LASCO SNAPLOK with PVC PIPE

EXTEND 18" FROM VALVE

SWING JOINT - MINIMUM 12" LAY LENGTH

LASCO - BRASS MALE 90 ELL OUTLET

COMPACTED

GROWING MEDIA

TRACER WIRE

12" SPRAY HEAD

TOP OF BED

TOP 6" SHALL BE SOIL

SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS

SERVICE TEE / SADDLE

4" / 6" SPRAY HEAD

TOP OF BED

SERVICE TEE / SADDLE

SWING JOINT

MAXIMUM LENGTH

OF FLEX PIPE - 18"

LATERAL LINE

TOP 6" SHALL BE SOIL

SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS

18" MIN

TOP OF PIPE

18" MIN

TOP OF PIPE

SWING JOINT

MAXIMUM LENGTH

OF FLEX PIPE - 18"

LATERAL LINE

MAINLINE PIPE

TWO-WIRE

CONTROL CABLE

METALLIC TRACER TAPE

PLACE IN TOP 6"

TOP 6" SHALL BE GROWING MEDIA

TRACER WIRE

18" MIN

TOP OF PIPE

DECODER - SINGLE STATION

ZIP TIE TO 36" LENGTH OF

1" PVC PIPE

BURY 12" OF PIPE TO SUPPORT

DECODER OR ZIP TIE TO VALVE BOX

DBR/Y-6 WIRE CONNECTOR

TWO-WIRE PATH

DBR/Y-6 WIRE CONNECTOR

TWO-WIRE PATH

FROM CONTROLLER.

ALLOW 5-FEET SLACK

PER DECODER

ELECTRIC VALVE

LATERAL PE PIPING

MALE INSERT FITTING

2 STAINLESS STEEL CLAMPS on 1.5" and LARGER.

1 STAINLESS STEEL HOSE CLAMP ON 1" PIPE.

6" EXTENTION VALVE BOX - IF REQUIRED

12" RECTANGULAR VALVE BOX

S-80 NIPPLE

MAINLINE PIPE

ID TAG

SUBGRADE

BASE COURSE

SUBGRADE

BASE COURSE

PAVEMENT

TYP.

SLEEVE FOR MAINLINE PIPE

SLEEVE FOR IRRIGATION WIRE

SLEEVE FOR LATERAL PIPE

24" MIN

TOP OF PIPE

24" MIN

TOP OF PIPE

SIDEWALK

EXTEND SLEEVES

2' BEYOND PAVEMENT

MAINLINE SLEEVE

CURB LINE

TYP.

EXTEND SLEEVES

2' BEYOND PAVEMENT

LATERAL SLEEVE

PAVEMENT

TYP.

VALVE BOX

DECODER CABLE FUSE DEVICE

(INLINE, TWO-WAY, THREE-WAY)

2" PVC PIPE USED AS RISER

RE-ENTERABLE CONNECTOR

FOR GROUNDING

LEADS FROM GROUND ROD

AND PLATE

TWO-WIRE CABLES OUT

WIRE SPLICES WITH DBR/Y-6 CONNECTORS

INCOMING TWO-WIRE CABLE

TWO-WIRE CABLE MARKING TAG

NOTCH FOR DCFD LEADS

BRING TOP OF DCFD TO JUST BELOW

BOTTOM OF VALVE BOX LID

12" BURY DEPTH MIN.

6" MIN.

3" MIN.

D 8'

10'

10'

30"

10" ROUND VALVE BOX w/ LID

WELDED CONDUCTOR

TO ROD

BARE #6 SOLID COPPER WIRE

FROM GROUND LUG INSIDE

SATELLITE CONTROLLER OR DECODER

MAXIMUM 12' IN LENGTH.

UNDISTURBED EARTH

5/8" x 8' COPPER CLAD GROUND ROD w/ WELDED CONDUCTOR

DO NOT CUT!

GROUND ROD

(SEE DETAIL)

GROUND ENHANCEMENT MATERIAL

50#s ON TOP OF PLATE and 50#s

ON BOTTOM OF PLATECOPPER GROUND PLATE

4" x 36"

10 AWG SOLID BARE

COPPER WIRES

RE-ENTERABLE TERMINAL

STRIP FOR ALL GROUNDING

CONNECTIONS

VALVE BOX PRE-WELDED CONNECTOR

6" MIN.

GROUND ROD

(SEE DETAIL)

COPPER GROUND PLATE

6 AWG SOLID

COPPER WIRES

TOP VIEW

SIDE VIEWNOTE: GROUNDING PLATE AND ALL OTHER

RELATED MATERIALS BY PAIGE ELECTRIC

CO. OR APPROVED EQUAL.NOT TO SCALE

EARTH GROUNDING

IT IS THE RESPONSIBILITY OF THE INSTALLER TO CONNECT

ALL ELECTRONIC IRRIGATION EQUIPMENT FOR WHICH THEY

ARE RESPONSIBLE TO EARTH GROUND. GROUNDING

COMPONENTS WILL INCLUDE THE ITEMS DESCRIBED IN THE

FOLLOWING PARAGRAPH, AT A MINIMUM.

AT THE VERY MINIMUM, THE GROUNDING CIRCUIT WILL

INCLUDE A COPPER CLAD STEEL GROUND ROD, A SOLID

COPPER GROUND PLATE, AND 100 POUNDS OF GEM EARTH

CONTACT MATERIAL AS DEFINED PER THE FOLLOWING DETAIL.

CONTRACTOR TO PROVIDE WRITTEN VERIFICATION FROM THE

PRODUCT DISTRIBUTOR THAT THE GROUND WAS "MEGGED"

AND THE OHMs ARE WITHIN THE ACCEPTABLE LIMITS.

PLANTING MEDIA

SURVEY RED-TOP MARKER

MARKING SENSOR LOCATION

SOIL SENSOR

WIRE RUN FROM SENSOR TO CONTROLLER

LEAD WIRES FROM SOIL SENSOR

1" PVC SLEEVE

3M DBY WIRE CONNECTOR

#14 AWG DIRECT BURY TRACER WIRE, LABEL END IN VALVE BOX

6" ROUND VALVE BOX

BED GRADE

ROTOR

TOP OF BED

SERVICE TEE / SADDLE

SWING JOINT

MAXIMUM LENGTH

OF FLEX PIPE - 18"

LATERAL LINE

TOP 6" SHALL BE SOIL

SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS

18" MIN

TOP OF PIPE

USE NO PIPE DOPE

USE TEFLON TAPE ONLY ON NPT THREADS

DIAGRAM - THRUST BLOCKS

NTS

NOTE:

ALL PIPING IS TO BE INSTALLED AND TESTED ACCORDING TO

THE MANUFACTURER'S INSTALLATION GUIDELINES.

THRUST BLOCK ALL GASKETED FITTINGS WERE CHANGE OF

DIRECTION OR SOILS REQUIRE BLOCKING.

CONCRETE BLOCKS WILL NOT BE ALLOWED.

ALL THRUST BLOCKS ARE TO BE POURED IN PLACE WITH

CONCRETE TO UNDISTURBED SOILS.

NOTE:

ALL PIPING IS TO BE INSTALLED AND TESTED ACCORDING TO

THE MANUFACTURER'S INSTALLATION GUIDELINES.

THRUST BLOCK ALL GASKETED FITTINGS WERE CHANGE OF

DIRECTION OR SOILS REQUIRE BLOCKING.

CONCRETE BLOCKS WILL NOT BE ALLOWED.

ALL THRUST BLOCKS ARE TO BE POURED IN PLACE WITH

CONCRETE TO UNDISTURBED SOILS.

CONCRETE SLAB

LONG SWEEP ELL

GROUND CONTROLLER PER MANUFACTURERS RECOMMENDATIONS

INCOMING SIGNAL WIRES

LOOP AND BUNDLE

FINISH GRADE

12" RECTANGULAR VALVE BOX

PUMP ENCLOSURE

FRONT OF ENCLOSURE

CONTROLLER MOUNT

POWER FROM INSIDE OF ENCLOSURE

ELECTRICAL CONDUIT FOR CONTROL WIRE

24"

BURY

STATION COMPONENTS:

A PUMP AND MOTOR

B CHECK VALVE

C PRESSURE TRANSDUCER WITH GAUGE

D BY-PASS VALVE

E FLOW SENSOR

F TEMP SENSOR

G MARINE GRADE ALUMINUM BASE (UNPAINTED)

H PUMP INTAKE ISOLATION VALVE

I PUMP DISCHARGE ISOLATION VALVE

J NORMALLY OPEN BFV MASTER VALVE

K MARINE GRADE ALUMINUM ENCLOSURE (UNPAINTED)

L STATION FAN HOOD MOUNTED

M RPZ FEBCO 825 - 2"

N 120V OUTLET FOR IRRIGATION CONTROLLER

O 2" BLOWOUT, WITH THREADED PLUG

P DEAD-FRONT DISCONNECT PANEL

Q OVAL FLANGES FOR NEPTUNE T-10 2" METER

R WYE STRAINER (REQUIRED DOWNSTREAM OF METER)

S EXTRA 1/4 " PORT FOR PSI SENSOR (IRR CONTROLLER)

T BASELINE DECODERS IN PANEL (FLOW DECODER, MV DECODER)

U VFD

NEC CLEARANCE

SEE LOCAL CODES

H

D C

J

E

G

L

K

DETAIL A

F

O

A

B

I

J

M

POWER

DISCONNECT

ENCLOSURE

ENCLOSURE FRONT

P,T

DESCRIPTION OF OPERATION

PUMP STATION WILL START ON A PRESSURE DROP SENSED IN

IRRIGATION MAINLINE. PUMP WILL REGULATE A CONSTANT

DISCHARGE PRESSURE AT VARIABLE FLOW RATE. PUMP WILL

RETIRE BASED UPON A SUSTAIN REGULATE PRESSURE OVER

TIME, AND REDUCTION IN FLOW.

IF IRRIGATION CONTROLLER SENSES UN-SCHEDULED FLOW OR

HIGH FLOW, IRRIGATION CONTROLLER WILL SHUT DOWN PUMP,

AND CLOSE MASTER VALVE.

PUMP STATION SHALL HAVE THE FOLLOWING ALARMS

LOW PRESSURE ALARM

HIGH PRESSURE ALARM

HIGH PUMP VOLUTE TEMP

MOTOR OVERLOAD SHUT DOWN

PHASE LOSS (3-PHZ SYSTEMS ONLY)

VFD FAULT SHUT DOWN

PUMP STATION SPECIFICATIONS:

NAME: 90 NORTH PUMP STATION #1

PUMP STATION TO BE MANUFACTURED BY WATERTRONICS,

PRECISION PUMPING, OR APPROVED EQUAL.

BASIS OF DESIGN: WATERTRONICS WATERMAX 5000

CONTACT ERIC PIFER @ 262-224-3263 FOR PRICING

STATION MODEL: WMBV-5000-7A-3-208-3-50-64

STATION TOTAL PERFORMANCE: 50 GPM @ 25 PSI BOOST

STATIC INLET PRESSURE: 55 PSI

DYNAMIC INLET PRESSURE: 39 PSI

DISCHARGE REGULATE PRESSURE: 64 PSI

PUMP NO.1 3HP (3600 RPM)

PUMP STATION INTAKE CONNECTION SIZE: 2"

PUMP STATION DISCHARGE CONNECTION SIZE:2"

POWER REQUIREMENTS

208V - 3PHZ - 60HZ - 18 FULL LOAD AMPS 17" METER

20" min 10" min

48"

SLAB

ENCLOSURE FRONT

17" METER

12" 52" BASE39"6" 6"

115" SLAB

13"

26"

BASE

9"

48"

SLAB

7"

35"

BASE

6"

FLOW

FLOW

2" FLANGE

CONNECTION TO IRRIGATION

2" RPZ DRAIN

TO GROUND SURFACE OR DRAIN

IRRIGATION CONTROLLER

MOUNTED BY CONTRACTOR

N

K

G

Q

R 4938"

U

S

24"

FLOW

CONNECTION BY CIVIL

CONTRACTOR

CONTINUED BY IRRIGATION

CONTRACTOR

24"O

DETAIL "A"

CONCRETE ANCHOR

TYPICAL

POWER

CONDUIT

FROM

UTILITY

REAR of ENCLOSURE

FLOW

IRRIGATION CONTROLLER

1-1/2"

CONDUIT

LI-501

IRRIGATION BOOSTER PUMP

STATION #1

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

K

Q

BC

N

PRESSURE

0 160

VFD

J IJ

A

E

F

E

D

G

R

VFD

RPZ DRAIN LINE TO

GROUND SURFACE OR DRAIN BY OTHERS

3" FLG

STATION COMPONENTS:

A PUMP AND MOTOR

B CHECK VALVE

C RPZ FEBCO MODEL# 880V-3"

D PRESSURE TRANSDUCER WITH GAUGE

E PRESSURE GAUGE LIQUID FILLED

F FLOW SENSOR

G NORMALLY OPEN BFV MASTER VALVE

H MARINE GRADE ALUMINUM BASE (UNPAINTED)

I STATION FAN HOOD MOUNTED

J MARINE GRADE ALUMINUM ENCLOSURE (UNPAINTED)

K DISCHARGE DROP PIPE W/ 3" FLG CONNECTION

L 120V OUTLET FOR IRRIGATION CONTROLLER

M OVAL FLANGES FOR NEPTUNE T-10 2" METER

N BY PASS VALVE

O BLOWOUT WITH PLUG

P DEAD FRONT DISCONNECT BOX

Q PUMP INTAKE ISOLATION VALVE

R PUMP DISCHARGE ISOLATION VALVE

S BASELINE DECODERS IN PANEL (FLOW DECODER, MV DECODER)

T 3" WYE STRAINER (REQUIRED DOWNSTREAM OF METER)

U EXTRA 1/4 " PORT FOR PSI SENSOR (IRR CONTROLLER)

DETAIL A

POWER

DISCONNECT

ENCLOSURE

STATION ENCLOSURE FRONTSTATION ENCLOSURE FRONT

NEC CLEARANCE

SEE LOCAL CODES

HH

P

17" METER

20" min

ENCLOSURE FRONT

26"

BASE

10" min

17" METER

FLOW

49 316"

IRRIGATION CONTROLLER

MOUNTED BY CONTRACTOR

6"52" BASE17"52" BASE12"39" BASE6"

184" SLAB

H

J

L

M

S

T

U

6"

3" FLANGE

CONNECTION TO IRRIGATION

PUMP STATION SPECIFICATIONS:

NAME: 90 NORTH PUMP STATION #2

PUMP STATION TO BE MANUFACTURED BY WATERTRONICS,

PRECISION PUMPING, OR APPROVED EQUAL.

BASIS OF DESIGN: WATERTRONICS WATERMAX 5000

CONTACT ERIC PIFER @ 262-224-3263 FOR PRICING

STATION MODEL: WMBV-5000-7A-5-208-3-100-60

STATION TOTAL PERFORMANCE: 100 GPM @ 25 PSI BOOST

STATIC INLET PRESSURE: 55 PSI

DYNAMIC INLET PRESSURE: 35 PSI

DISCHARGE REGULATE PRESSURE: 60 PSI

PUMP NO.1 5HP (3600 RPM)

PUMP STATION INTAKE CONNECTION SIZE: 2"

PUMP STATION DISCHARGE CONNECTION SIZE:2"

POWER REQUIREMENTS

208V - 3PHZ - 60HZ - 21 FULL LOAD AMPS

48"

SLAB35"

BASE

DESCRIPTION OF OPERATION

PUMP STATION WILL START ON A PRESSURE DROP SENSED IN

IRRIGATION MAINLINE. PUMP WILL REGULATE A CONSTANT

DISCHARGE PRESSURE AT VARIABLE FLOW RATE. PUMP WILL

RETIRE BASED UPON A SUSTAIN REGULATE PRESSURE OVER

TIME, AND REDUCTION IN FLOW.

IF IRRIGATION CONTROLLER SENSES UN-SCHEDULED FLOW OR

HIGH FLOW, IRRIGATION CONTROLLER WILL SHUT DOWN PUMP,

AND CLOSE MASTER VALVE.

PUMP STATION SHALL HAVE THE FOLLOWING ALARMS

LOW PRESSURE ALARM

HIGH PRESSURE ALARM

HIGH PUMP VOLUTE TEMP

MOTOR OVERLOAD SHUT DOWN

PHASE LOSS (3-PHZ SYSTEMS ONLY)

VFD FAULT SHUT DOWN

DETAIL "A"

CONCRETE ANCHOR

TYPICAL

POWER

CONDUIT

FROM

UTILITY

REAR of ENCLOSURE

FLOW

15"

CONNECTION BY CIVIL

CONTRACTOR

CONTINUED BY IRRIGATION

CONTRACTOR

24"24"O

IRRIGATION CONTROLLER

1-1/2"

CONDUIT

LI-502

IRRIGATION BOOSTER PUMP

STATION #2

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

ISSUANCES

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

C-2

POC-2

BFPP2

Wx

B

A

736 735

734734

733 732

733734

8 73

PR

O G R

ESS PAR

KW

AY (TW

O W

AY)

PARK

SIDE

DRIV

E (TW

O WAY)

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

6"/2"sl

3"sl

3"sl

3"sl

3"sl

6"/2"sl

6" /2

"s l

6"/2"sl

3"sl

6"/2"sl

3"sl

4"sl

3"sl 3"sl

6"/2"sl

3" sl

3"sl

8" /2

"s l

8"/2"sl

4" sl

3" sl

6" /2

"s l

3"sl

4"sl

4"sl

3"sl 3"sl

4"sl

4"sl

3"sl

6"/2"sl

6"/2"sl

6"/2"sl

3"/1"sl

G

S2

S2

S2

S2

S2

G

G

G

G

G

G

4"sl 4"sl

SMS

SMS

G

Wx

LEGEND

TWO-WIRE PATH ROUTE

WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow

TWO-WIRE PATH ROUTE

WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red

SLEEVE - (BORING REQUIRED) - Size per Plan

SLEEVE - Size per Plan

PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE

PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE

MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN

OPEN SKY ON THE PUMP ENCLOSURE.

INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)

BASELINE SOIL MOISTURE SENSOR

S2

S1

SMS

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park

Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

M

AT

C H L

IN

E

LI

-7

M

AT

C H L

IN

E

LI

-7

LI-700

TWO-WIRE SCHEMATIC

ENLARGEMENT A

TWO-WIRE SCHEMATIC ENLARGEMENT A

POC-1

C-1

BFPP1

Wx

732 732

S2

S2

PAR

KSID

E DR

IVE (

TWO W

AY)

LANDM

ARK DRIVE (TW

O W

AY)

4"sl

3"sl

3"sl

4"sl

4"sl

3"sl

4" /2

"s l

3"sl

4"sl

3"sl

6" /2

"s l

3"sl

3"sl

G

G

G

G

G

INSTALL 2ND TWO-WIRE DECODER

WIRE IN A 10" VALVE BOX FOR

FUTURE USE. PROTECT ENDS.

G

SMS

4"/4"sl

Wx

LEGEND

TWO-WIRE PATH ROUTE

WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow

TWO-WIRE PATH ROUTE

WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red

SLEEVE - (BORING REQUIRED) - Size per Plan

SLEEVE - Size per Plan

PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE

PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE

MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN

OPEN SKY ON THE PUMP ENCLOSURE.

INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)

BASELINE SOIL MOISTURE SENSOR

S2

S1

SMS

LI-701

TWO-WIRE SCHEMATIC

ENLARGEMENT B

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park

Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

M

AT

C H L

IN

E

LI

-7

M

AT

C H L

IN

E

LI

-7

M

AT

C H L

IN

E

LI

-7

M

AT

C H L

IN

E

LI

-7

TWO-WIRE SCHEMATIC ENLARGEMENT B

729 728

S2

AR

BO

R D R

IVE (TW

O W

AY)

PARKSIDE DRIVE (TWO WAY)

3" sl

3" sl

4" /2

"s l

G

G

3" sl

Wx

LEGEND

TWO-WIRE PATH ROUTE

WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow

TWO-WIRE PATH ROUTE

WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red

SLEEVE - (BORING REQUIRED) - Size per Plan

SLEEVE - Size per Plan

PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE

PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY

PRECIPITATION SENSOR --

PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE

MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN

OPEN SKY ON THE PUMP ENCLOSURE.

INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)

BASELINE SOIL MOISTURE SENSOR

S2

S1

SMS

LI-702

TWO-WIRE SCHEMATIC

ENLARGEMENT C

Date Issued

Sheet Title:

Drawing Number:

Progress Parkway, Schaumburg, IL 60173

Schaumburg 90 NDW Urban Park

Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605

p. 312.427.7240 w. www.site-design.com

V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517

p. 630.724.9200 w. www.v3co.com

Rev. #

File :

Approved :

Drawn :

Project No :

Scale : AS NOTEDChecked :

90N Park Irrigation.dwg

08/04/202301 Phase 2 External Irrigation

DF

MZ

DF

Description

M

AT

C H L

IN

E

LI

-7

M

AT

C H L

IN

E

LI

-7

TWO-WIRE SCHEMATIC ENLARGEMENT C

File details come from the government source that posted it. Updated .