Irrigation_Plans_.pdf
PDF 6 MB Posted
- Attached to
- 90 North Park Irrigation
- Solicitation number
- 2023-IFB-066
- Issued by
- Cook County, Illinois
About this file
The provided document is a comprehensive set of irrigation plans for the Schaumburg 90 NDW Urban Park project located in Schaumburg, Illinois, prepared by site design group, ltd. (Landscape Architect) and V3 Companies (Engineer). The plans include detailed irrigation system design across multiple sheets, covering enlargement areas such as the main irrigation plan, shared street irrigation, hammock grove, and two-wire schematic plans. The documents specify intricate irrigation infrastructure including mainline pipes, lateral pipes, valve boxes, controllers (Baseline BL-3200 and BL-Sub Station), rain gauges, soil moisture sensors, and two booster pump stations (Stations #1 and #2). The plans outline precise pipe sizing, valve locations, wire routing, and installation specifications for a comprehensive irrigation system spanning the urban park development.
The irrigation system design incorporates sophisticated technical elements like a two-wire decoder system, electric valves, backflow preventers, and detailed grounding requirements. The project includes multiple irrigation controllers (labeled C-1 and C-2) with specific mounting and installation instructions, and provisions for future expansion. The booster pump stations are detailed with specific power requirements, connection specifications, and concrete anchoring details. The plans demonstrate a high-level of engineering precision, including specifications for pipe sleeves, wire trenches, valve boxes, and comprehensive grounding schematics. The irrigation system is designed to support various landscape zones with different pipe sizes ranging from 1" to 15", and includes provisions for soil moisture sensing and rain gauge integration to optimize water usage efficiency.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2"
2"
3" 3"
3"
3"
3"
3"
3"
3"
3"3"
3"
2"
4"
3"
3"
4"
3"
2"
2"
2"
2"
1"
2"
2"
1"
1"
1"
2"
2"
2"
2"
1"
1"
2"
2"
2"
1"
2"
2"
1"
2"
2"
2"
1"
2"
2"
2"
1"
1"
2"
2"
2"
1"
2"
2"
2"
1"
2"
2"
2"
2"
1"
2"
2"
2"
2"
1"
2"
2"
2"
2"
1" 1"
2"
1"
2"
2"
1"2"
2"
1"
2"
2"
1"
1"
1"
2"
2"
2"
2"
1"
2"
1" 11 2"
1"
2"
2"
2"
1"
2"
2" 11 2"
2" 2"
2"
2"
2"
1"
2"
2"
2"
2"
1"
2"
2"
1"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
1"
1"
2"
2"
2"11
2"
2"
2"
2"
2"
2"
2"
2"
2" 2"
2"
2"
2"
2"
2"
2"
1"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
1" 1"
1"
2"
2"
2" 11
2"11 2"1"
2"
2"
2" 11
2" 1"
2"
2" 1" 1"
2"
2"
2"
2"
2"
2"
1"
2"
2"
2" 11 2"
2"
2"
2" 11 2"
1"
2"
2"
2"
2"
1"
2"
2"11
2"
2"
2"11 2"11
2"
1"
1"
1"
1"
1"1"
2"
1" 1"
2"
2"
2"
2"
1"
2"
2" 11
2"
1"
2"
2" 1"
1"
2"
1"
2"
2"
2"
1"
1" 1"
2"
2"
2"
2"
1"
1" 1"
1"
1"
2"
2"
2"11
2"
2"
2"
2"
1"
1"
1"
1" 1"
1"
1"
1"
1"
2"1"
2"
1"
1" 1"
1" 1"
1"
2"
2"
2"
2"
1"
1"
2"
1"
2"
2"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1" 11 2"
2"
2"
2"
2"
2"
2"
2"
1"
2"
2"
2"
2"
1"
1"
1"
2"
2"
2"
2"
2"
2"
1"
2"
2"
2"
2"
2"
2"
2"
1"
2"
1"
2"
1" 2"
2"
2"
2"
2-1 39112"
2-2 10.71"
2-3 28.3112"
2-4 34.6112"
2-5 51.5112"
2-6 18.91"
2-7 151"
2-8 36112"
2-9 42112"
2-10 26.5112"
2-11 31.4112"
2-12 36.6112"
2-13 36112"
2-14 30112"
2-15 36112"
2-16 28.5112"
2-17 31.5112"
2-18 42112"
2-19 36112" 2-20
36112"
2-21 36112"
2-22 28112"
2-24 27.4112"
2-25 38.0112"
2-26 34.4112"
2-27 11.51"
2-28 45.2112"
2-29 27.5112"
2-30 37.1112"
2-31 30112"
2-36 42112"
2-37 34.5112"
2-38 48112"
2-39 48112"
2-40 42112"
2-41 42112"
2-42 42112"
2-43 24.01"
2-44 42112"
2-45 30112"
2-46 36112"
2-47 42112"
2-48 10.51"
2-49 42112"
2-50 44.5112"
2-51 42112"
2-52 36112"
2-53 42112"
2-23 28.0112"
2-54 29.8112" 2-55
38.8112"
C-2
POC-2
BFPP2
Wx
B
A
736 735
734734
733 732
733734
8 73
PR
O G R
ESS PAR
KW
AY (TW
O W
AY)
PARK
SIDE
DRIV
E (TW
O WAY)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
3.0
3.0
3.0
3.0
3.0
3.0
1.5
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0 6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0
6.0
3.0
3.0
3.0
2.5
1.5
1.5
3.0
3.0
3.0
3.0
3.0
1.5
1.5 3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.5
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
6.0
6.0
6.0
6.06.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5 1.5
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
3.0
3.0
3.0
3.0 3.0
2.0
1.5
2.0
3.0
3.0
3.0 3.0
3.0 3.0
3.0
3.0
3.0
4.0
1.5
1.5
6.0 3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
3.0
3.0
3.0
1.5
1.5
3.0
3.0
2.5
1.5
2.0
3.0
3.0
3.0
3.0
3.0 3.0
3.0
3.0
2.0
1.5
K
K
B
B
B
B
B
B
B
B
B
B
B
B
R
R
1.5
3.0
3.0
3.0
3.0
2.0
3.0
3.0
1.53.03.03.03.03.01.5
1.5
1.5
3.0 3.0
3.0
3.0
6.0
3"sl
01 21
01 01
8 8
8 8
21 21
21 21
01 01
E
E
3"sl
6"/2"sl
51 51
51 51
51 51
51 51
5151 51
8 8
8 8
8 8
8 8
8 8
8 8
8 8 8
8 8
51 51
8 8
8 8
51 51
51 51
51 51
51 51
5151 51
51 51
51 51
51 51
3"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
3"sl
6"/2"sl
6" /2
"s l
6"/2"sl
3"sl
6"/2"sl
3"sl
4"sl
3"sl 3"sl
6"/2"sl
3" sl
3"sl
8" /2
"s l
8"/2"sl
4" sl
3" sl
6" /2
"s l
3"sl
4"sl
4"sl
3"sl 3"sl
4"sl
4"sl
3"sl
6"/2"sl
6"/2"sl
6"/2"sl
3"/1"sl
4"sl 4"sl
2000 30002000
POC-1
POC-2
1-X
2-X
Wx
LEGEND
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
5' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
8' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
10' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
12' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
15' Series
HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD
Full/Part Circle Nozzles, Noted
HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD
with HUNTER MP ROTATOR NOZZLE - AS NOTED
HUNTER I-20-PRB 6" ROTOR
Full/Part Circle - Nozzles As Noted
RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan
BUCKNER 34" QUICK COUPLER VALVE
Provide Owner with Valve Keys and Hose Swivels
(2) Keys; (2) Hose Swivels
ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe
Class 200 PVC Mainline Pipe - Size per Plan
HDPE DR 15 Lateral Pipe - Size per Plan
SLEEVE - (BORING REQUIRED) - Size per plan
SLEEVE - Size per Plan
POINT OF CONNECTION - 2"
Labeled as POC-1.
Design Pressure - 55 psig prior to RPZ.
POINT OF CONNECTION - 3"
Labeled as POC-2.
Design Pressure -55 psig prior to RPZ.
IRRIGATION CONTROLLER
Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-PLUS-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.
Install Bird Spikes on upper edge of gauge (4"Ø)
BASELINE SOIL MOISTURE SENSOR
IRRIGATION CONTROLLER - SUBSTATION
Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL
CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-SUBSTN-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
2" WINTERIZATION PORT on pump station discharge pipe.
IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)
PUMP 1 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64
205V 3 PHASE 60HZ - 18 FULL LOAD AMPS
50 GPM @ 25 PSI BOOST - See Pump Details
PUMP 2 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60
208V 3 PHASE 60HZ - 21 FULL LOAD AMPS
100 GPM @ 25 PSI BOOST - See Pump Details
4" / 2"sl Sleeve / Bore
Wire Sleeve Size Pipe Sleeve Size
Station Number Controller Number
351" 1-24
Zone GPM Valve Size
P2
P1
ES CS SSRCSLCS
Q H F
FHTQ
FHTQ
ES CS SSRCSLCS
E L R C S
4 6 8 01 21 51 71
1.5 2.0 2.5
3.0 4.0 5.0 6.0
BFP
Q T H TT TQ F
Q T H TT TQ F
K BR
SMS
LI-400
IRRIGATION PLAN
ENLARGEMENT A
SEE ENLARGEMENT - SHEET LI-410
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park
Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
IRRIGATION PLAN ENLARGEMENT A
1" = 30'-0"1
M
AT
C H L
IN
E
LI
-4
M
AT
C H L
IN
E
LI
-4
0 30 60'10 20 40 50
3"
3"
3"
2"
2"
2"
2"
2"
3"
3"
STUB MAINLINE FOR FUTURE
IRRIGATION SYSTEM EXPANSION
WITH DECODER WIRE. SEE
TWO-WIRE PLANS.
1"
1"
2"
2"
1"
1"
2"
2"
1"
1"
2"
2"
1"
2"
1"
1"
1"
1"
1"1"
2"
1"
2"
2"
2"
2"
2"
1"
2"
2"
2"
2"
2"11
2"
2"
1"
1"
2"
2"
2"
2"
2"
2" 11
2"
1"1"
1" 1"
2"
1"1"
2"
2"
1"11 2"
2"
1"
2"
1"
1"
2"
2"
2"
1"
2"
2"
2"
2"
1"
1"
2"
2"
2"
2"11
2"
2" 1"
2"
1"
2"
2"
2"
2" 1"
1"
1"
1"
2"
2"
2"
2"
2"2"
2"
1"1"
2"
2"
2"
1"11 2"
1"1"
1"
2" 2"
1" 1"
2"
1"
2"
2"
2"
2"
2"
2"
2"
2"
1-4 26.5112"
1-3 31.5112"
1-1 7.021"
1-10 40112"
1-11 30112"
1-13 24112"
1-12 36112"
1-9 33112"
1-8 42112"
1-2 42112"
1-5 32112"
1-6 30112"
1-14 36112"
1-7 29.5112"
2-32 36112"
2-33 30.5112"
2-34 42112"2-35
25.9112"
2-36
2-56 38.8112"
2-57 38.8112"
POC-1
C-1
BFPP1
Wx
732 732
PAR
KSID
E DR
IVE (
TWO W
AY)
LANDM
ARK DRIVE (TW
O W
AY)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
1.5
2.0
2.03.0 3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
1.5
1.5 3.0
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0
1.5
3.0
2.0
6.0
6.0 6.0 6.0 6.0
6.06.06.06.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5 1.5
2.0 2.0
3.0
3.0
1.5 3.0
3.0
2.0
3.0 3.0
3.0
3.03.0 3.0
3.0
3.0 3.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
3.0
3.0
3.0
3.0
3.0
2.0
1.5
2.0
3.0
3.0
3.0
2.0
1.5
3.0
1.5
2.0
3.0
3.0
3.0
3.0
3.0
6.0
6.0
6.0
6.0 6.0
6.0
6.0
6.0
6.0
6.0 6.0
5.0 2.5
51 51
515 51
51 51
51 51
5151 51
5151 51 51
51 51
51 51
4"sl
3"sl
3"sl
4"sl
4"sl
3"sl
4" /2
"s l
3"sl
4"sl
3"sl
6" /2
"s l
3"sl
3"sl
4"/4"sl
2000 30002000
POC-1
POC-2
1-X
2-X
Wx
LEGEND
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
5' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
8' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
10' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
12' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
15' Series
HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD
Full/Part Circle Nozzles, Noted
HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD
with HUNTER MP ROTATOR NOZZLE - AS NOTED
HUNTER I-20-PRB 6" ROTOR
Full/Part Circle - Nozzles As Noted
RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan
BUCKNER 34" QUICK COUPLER VALVE
Provide Owner with Valve Keys and Hose Swivels
(2) Keys; (2) Hose Swivels
ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe
Class 200 PVC Mainline Pipe - Size per Plan
HDPE DR 15 Lateral Pipe - Size per Plan
SLEEVE - (BORING REQUIRED) - Size per plan
SLEEVE - Size per Plan
POINT OF CONNECTION - 2"
Labeled as POC-1.
Design Pressure - 55 psig prior to RPZ.
POINT OF CONNECTION - 3"
Labeled as POC-2.
Design Pressure -55 psig prior to RPZ.
IRRIGATION CONTROLLER
Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-PLUS-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.
Install Bird Spikes on upper edge of gauge (4"Ø)
BASELINE SOIL MOISTURE SENSOR
IRRIGATION CONTROLLER - SUBSTATION
Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL
CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-SUBSTN-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
2" WINTERIZATION PORT on pump station discharge pipe.
IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)
PUMP 1 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64
205V 3 PHASE 60HZ - 18 FULL LOAD AMPS
50 GPM @ 25 PSI BOOST - See Pump Details
PUMP 2 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60
208V 3 PHASE 60HZ - 21 FULL LOAD AMPS
100 GPM @ 25 PSI BOOST - See Pump Details
4" / 2"sl Sleeve / Bore
Wire Sleeve Size Pipe Sleeve Size
Station Number Controller Number
351" 1-24
Zone GPM Valve Size
P2
P1
ES CS SSRCSLCS
Q H F
FHTQ
FHTQ
ES CS SSRCSLCS
E L R C S
4 6 8 01 21 51 71
1.5 2.0 2.5
3.0 4.0 5.0 6.0
BFP
Q T H TT TQ F
Q T H TT TQ F
K BR
SMS
LI-401
IRRIGATION PLAN
ENLARGEMENT B
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park
Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
IRRIGATION PLAN ENLARGEMENT B
1" = 30'-0"1
0 30 60'10 20 40 50
M
AT
C H L
IN
E
LI
-4
M
AT
C H L
IN
E
LI
-4
M
AT
C H L
IN
E
LI
-4
M
AT
C H L
IN
E
LI
-4
2"
2"
2"
2"
2"
2"
1"
1"
2"
2"
2"
2"
2"
1"
2"
1"
2"
1"
2"
2"
2"
2" 11
2" 1"11 2"
1"
2" 11 2"
1"
1"
2"
2"
2"
1-16 31.5112"
1-15 31.5112"
1-17 39.5112"
1-18 33112"
1-19 151"
1-20 24.51"
729 728
AR
BO
R D R
IVE (TW
O W
AY)
PARKSIDE DRIVE (TWO WAY)
3.0 3.0
3.0 3.0 3.0 3.0 3.0 1.5
3.0
3.0
1.51.5
4.0
3.0 1.5
3.0
1.5
1.5
3.0
3.0
3.0
3.0
3.0
3.0 3.0
2.0 2.0
3.0
2.0
3.0
3.0
3.0
2.5
3.0 3.0 3.0 3.0 3.0
3.0 2.0
2.0
1.5
2.0
3.0 3.0
3.0
3.0
3.0
1.5
3.0
6.0 4.0
2.0
3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 1.5
1.5
2.0 2.0
2.02.02.03.03.0 3.0 3.0 3.0 3.03.0
3" sl
3" sl
4" /2
"s l
3" sl
2000 30002000
POC-1
POC-2
1-X
2-X
Wx
LEGEND
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
5' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
8' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
10' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
12' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
15' Series
HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD
Full/Part Circle Nozzles, Noted
HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD
with HUNTER MP ROTATOR NOZZLE - AS NOTED
HUNTER I-20-PRB 6" ROTOR
Full/Part Circle - Nozzles As Noted
RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan
BUCKNER 34" QUICK COUPLER VALVE
Provide Owner with Valve Keys and Hose Swivels
(2) Keys; (2) Hose Swivels
ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe
Class 200 PVC Mainline Pipe - Size per Plan
HDPE DR 15 Lateral Pipe - Size per Plan
SLEEVE - (BORING REQUIRED) - Size per plan
SLEEVE - Size per Plan
POINT OF CONNECTION - 2"
Labeled as POC-1.
Design Pressure - 55 psig prior to RPZ.
POINT OF CONNECTION - 3"
Labeled as POC-2.
Design Pressure -55 psig prior to RPZ.
IRRIGATION CONTROLLER
Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-PLUS-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.
Install Bird Spikes on upper edge of gauge (4"Ø)
BASELINE SOIL MOISTURE SENSOR
IRRIGATION CONTROLLER - SUBSTATION
Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL
CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-SUBSTN-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
2" WINTERIZATION PORT on pump station discharge pipe.
IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)
PUMP 1 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64
205V 3 PHASE 60HZ - 18 FULL LOAD AMPS
50 GPM @ 25 PSI BOOST - See Pump Details
PUMP 2 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60
208V 3 PHASE 60HZ - 21 FULL LOAD AMPS
100 GPM @ 25 PSI BOOST - See Pump Details
4" / 2"sl Sleeve / Bore
Wire Sleeve Size Pipe Sleeve Size
Station Number Controller Number
351" 1-24
Zone GPM Valve Size
P2
P1
ES CS SSRCSLCS
Q H F
FHTQ
FHTQ
ES CS SSRCSLCS
E L R C S
4 6 8 01 21 51 71
1.5 2.0 2.5
3.0 4.0 5.0 6.0
BFP
Q T H TT TQ F
Q T H TT TQ F
K BR
SMS
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
M
AT
C H L
IN
E
LI
-4
M
AT
C H L
IN
E
LI
-4
LI-402
IRRIGATION PLAN
ENLARGEMENT C
IRRIGATION PLAN ENLARGEMENT C
1" = 30'-0"1
2"
2"
2"
2"
2"
2"
2"11
2"
2"
2" 2" 2"2"
2"11 2"
2"
2"
2" 11
2" 1"
2"
2" 1" 1"
2"
111 " 1" 1"
2" 11
2"
1"
2"
2" 1"
1"
2"
1"
2"
2"
2"
1"
1" 1"
2"
2"
2"
2"
1"
1" 1"
1"
1"
1"
1"
1" 11 2"
2"
2"
2"
1"
2"
2"
2"
2"
2"
1"
2"
2-16 28.5112"
2-17 31.5112"
2-18 42112"
2-19 36112" 2-20
36112"
2-21 36112"
2-22 28112"
2-54 29.8112" 2-55
38.8112"
2-56
6.0
6.0 6.0
6.0
3.0
1.5 1.5
3.0
3.0 3.0
3.0 3.0
3.0
1.5
1.5
6.0 3.0
3"sl
01 01
8 8
8 8
21 21
21 21
01 01
3"sl
6"/2"sl
51 51
51 51
51 51
51 51
5151 51
8 8
8 8
8 8
8 8
8 8
8 8
8 8 8
8 8
51 51
8 8
8 8
51 51
51 51
51 51
51 51
5151 51
51 51
51 51
51 51
3"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
3"sl
6"/2"sl
6" /2
"s l
6"/2"sl
3"sl
6"/2"sl
3"sl
4"sl
3"sl 3"sl
6"/2"sl
4"sl
2000 30002000
POC-1
POC-2
1-X
2-X
Wx
LEGEND
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
5' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
8' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
10' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
12' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
15' Series
HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD
Full/Part Circle Nozzles, Noted
HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD
with HUNTER MP ROTATOR NOZZLE - AS NOTED
HUNTER I-20-PRB 6" ROTOR
Full/Part Circle - Nozzles As Noted
RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan
BUCKNER 34" QUICK COUPLER VALVE
Provide Owner with Valve Keys and Hose Swivels
(2) Keys; (2) Hose Swivels
ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe
Class 200 PVC Mainline Pipe - Size per Plan
HDPE DR 15 Lateral Pipe - Size per Plan
SLEEVE - (BORING REQUIRED) - Size per plan
SLEEVE - Size per Plan
POINT OF CONNECTION - 2"
Labeled as POC-1.
Design Pressure - 55 psig prior to RPZ.
POINT OF CONNECTION - 3"
Labeled as POC-2.
Design Pressure -55 psig prior to RPZ.
IRRIGATION CONTROLLER
Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-PLUS-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.
Install Bird Spikes on upper edge of gauge (4"Ø)
BASELINE SOIL MOISTURE SENSOR
IRRIGATION CONTROLLER - SUBSTATION
Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL
CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-SUBSTN-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
2" WINTERIZATION PORT on pump station discharge pipe.
IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)
PUMP 1 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64
205V 3 PHASE 60HZ - 18 FULL LOAD AMPS
50 GPM @ 25 PSI BOOST - See Pump Details
PUMP 2 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60
208V 3 PHASE 60HZ - 21 FULL LOAD AMPS
100 GPM @ 25 PSI BOOST - See Pump Details
4" / 2"sl Sleeve / Bore
Wire Sleeve Size Pipe Sleeve Size
Station Number Controller Number
351" 1-24
Zone GPM Valve Size
P2
P1
ES CS SSRCSLCS
Q H F
FHTQ
FHTQ
ES CS SSRCSLCS
E L R C S
4 6 8 01 21 51 71
1.5 2.0 2.5
3.0 4.0 5.0 6.0
BFP
Q T H TT TQ F
Q T H TT TQ F
K BR
2"
2"2"
2"
1"1"
2"
2"
2"
1"11 2"
1"1"
1"
2" 2"
1" 1"
2"
2"
2"
2"
2"
2-56 38.8112"
2-57 38.8112"
51 51
51 51
51 51
5151 51
5151 51 51
51 51
51 51
4"sl
3"sl
3"sl
4"sl
4"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
4"sl
3"sl
3"sl
4"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
3"sl
6"/2"sl
6" /2
"s l
6"/2"sl
3"sl
6"/2"sl
3"sl
4"sl
4"sl
3"sl 3"sl
6"/2"sl
4"sl
G
S2 G
G
SMS
Wx
LEGEND
TWO-WIRE PATH ROUTE
WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow
TWO-WIRE PATH ROUTE
WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red
SLEEVE - (BORING REQUIRED) - Size per Plan
SLEEVE - Size per Plan
PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE
PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE
MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN
OPEN SKY ON THE PUMP ENCLOSURE.
INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)
BASELINE SOIL MOISTURE SENSOR
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
LI-403
SHARED STREET IRRIGATION
IRRIGATION PLAN ENLARGEMENT SHARED STREET
1" = 30'-0"1
0 30 60'10 20 40 50
M
AT
C H L
IN
E
SE
E
BE
LO
W
M
AT
C H L
IN
E
SE
E
AB
O
VE
TWO-WIRE SCHEMATIC PLAN SHARED STREET
1" = 50'-0"1
0 50 100'
3"
3"
2"
2"
2"
2"
1"
2"
1"
2"
1"
1"
11 "
1"
2"
1"
1"
1"
2"
2"
1"
1"
1"
2"
2"
2"
2"
1"
2"
2"
2"11
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2" 11
2" 1"
2"
2" 1" 1"
2"
2"
2"
2"
2"
2"
1"
2"
2"
2"11 2"11
2"
1"
1"
1"
1"
1"1"
2"
1" 1"
2"
2"
2"
2"
1"
2"
2" 11
2"
1"
2"
2" 1"
1"
2"
2"
2"
2"
1"
2"
1"
2"
1"
1"
1"
1"
1"
1"
1"
1" 11 2"
2"
2"
2"
2"
2"
2"
2"
2"
1"
2"
1" 2"
2"
2"
2"
2-20 36112"
2-21 36112"
2-22 28112"
2-24 27.4112"
2-25 38.0112"
2-26 34.4112"
2-27 11.51"
2-28 45.2112"
2-29 27.5112"
2-30 37.1112"
2-52 36112"
2-53 42112"
2-23 28.0112"
2-54 29.8112" 2-55
38.8112"
736 735
734734
733 732
733734
8 73
3.0
3.0
3.0
3.0
3.0
3.0
3.0
1.5
3.0
3.0
3.0
3.0
3.0
3.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
3.0 3.0
3.0
3.0
3.0
4.0
1.5
6.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0 3.0
3.0
3.0
2.0
1.5
3"sl
01 21
01 01
8 8
8 8
21 21
21 21
01 01
E
E
3"sl
8 8
8 8
51 51
8 8
51 51
51 51
5151 51
51 51
51 51
51 51
3"sl
3"sl
6"/2"sl
6"/2"sl
3"sl
3"sl
3"sl
6"/2"sl
6" /2
"s l
3"sl
6"/2"sl
3"sl
4"sl
3"sl
6"/2"sl
6" /2
"s l
3"sl
4"sl
4"sl
3"sl 3"sl
6"/2"sl
6"/2"sl
3"/1"sl
2000 30002000
POC-1
POC-2
1-X
2-X
Wx
LEGEND
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
5' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
8' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
10' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
12' Series
HUNTER PROS-04-PRS30-CV 4" SPRAY HEAD
15' Series
HUNTER PROS-12-PRS30-CV 12" SPRAY HEAD
F Strip Series
HUNTER PROS-04-PRS30-CV 12" SPRAY HEAD
Full/Part Circle Nozzles, Noted
HUNTER PROS-04-PRS40-CV 4" SPRAY HEAD
with HUNTER MP ROTATOR NOZZLE - AS NOTED
HUNTER I-20-PRB 6" ROTOR
Full/Part Circle - Nozzles As Noted
RAIN BIRD PEB SERIES ELECTRIC VALVE - Size per Plan
BUCKNER 34" QUICK COUPLER VALVE
Provide Owner with Valve Keys and Hose Swivels
(2) Keys; (2) Hose Swivels
ISOLATION GATE VALVE - Leemco LGV Series -- Size to Pipe
Class 200 PVC Mainline Pipe - Size per Plan
HDPE DR 15 Lateral Pipe - Size per Plan
SLEEVE - (BORING REQUIRED) - Size per plan
SLEEVE - Size per Plan
POINT OF CONNECTION - 2"
Labeled as POC-1.
Design Pressure - 55 psig prior to RPZ.
POINT OF CONNECTION - 3"
Labeled as POC-2.
Design Pressure -55 psig prior to RPZ.
IRRIGATION CONTROLLER
Labeled as C-1 Model BASELINE BL-3200XS LARGE STAINLESS STEEL CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-PLUS-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- Baseline Tipping Bucket Rain Gauge Model #BL-5407-KIT ; Install per manufacturer's directions in open sky on the pump enclosure.
Install Bird Spikes on upper edge of gauge (4"Ø)
BASELINE SOIL MOISTURE SENSOR
IRRIGATION CONTROLLER - SUBSTATION
Labeled as C-2 Model BASELINE BL-SUBSTATION -XS LARGE STAINLESS STEEL
CONTROLLER
W/ CELL MODEM, BASELINE MODEL #BL-CM4G-X-AT/VZ
W/ FIVE YEAR SUBSCRIPTION, BASELINE MODEL
#BL-BMW2-SUBSTN-5YR
Mount per detail. Install and ground per manufacturer's recommendations and details. 120v power to be provided. Irrigation Contractor to make final connections. Install Paige #250090LED Surge Arrester at controller.
2" WINTERIZATION PORT on pump station discharge pipe.
IRRIGATION BACKFLOW (To Be located with Meter in Pump Station Enclosure)
PUMP 1 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-3-208-3-50-64
205V 3 PHASE 60HZ - 18 FULL LOAD AMPS
50 GPM @ 25 PSI BOOST - See Pump Details
PUMP 2 - WATERTRONICS BOOSTER PUMP STATION
WATERMAX 5000 MODEL: WMBV-5000-7A-5-208-3-100-60
208V 3 PHASE 60HZ - 21 FULL LOAD AMPS
100 GPM @ 25 PSI BOOST - See Pump Details
4" / 2"sl Sleeve / Bore
Wire Sleeve Size Pipe Sleeve Size
Station Number Controller Number
351" 1-24
Zone GPM Valve Size
P2
P1
ES CS SSRCSLCS
Q H F
FHTQ
FHTQ
ES CS SSRCSLCS
E L R C S
4 6 8 01 21 51 71
1.5 2.0 2.5
3.0 4.0 5.0 6.0
BFP
Q T H TT TQ F
Q T H TT TQ F
K BR
SMS
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
HAMMOCK GROVE IRRIGATION PLAN ENLARGEMENT
1" = 20'-0"1
0 10 20 30 40' LI-410
HAMMOCK GROVE IRRIGATION
PLAN ENLARGEMENT
LI-500
IRRIGATION DETAILS
ISOLATION VALVE - 2" and 3"
NTS6
PUSH-ON GATE VALVE - 4" and LARGER
NTS7
QUICK COUPLER VALVE
NTS2
12" SPRAY HEAD
NTS
4" SPRAY HEAD
NTS54
WIRE TRENCH
NTS14 ELECTRIC VALVE with biCoder
NTS15ELECTRIC VALVE
NTS13
SLEEVING
NTS3
DECODER CABLE FUSE DEVICE
NTS
GROUNDING SCHEMATIC
NTS11
SOIL SENSOR
NTS1
I-20 4" ROTOR - GENERAL TURF
NTS12
DIAGRAM - THRUST BLOCKS
NTS
DIAGRAM - IRRIGATION CONTROLLER MOUNTING
NTS8
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
FINISH GRADE
GROWING MEDIA
10" ROUND VALVE BOX
8" CORRUGATED PE PIPE
LENGTH AS REQD.
IRRIGATION LINE
UNDISTURBED SOIL
HDPE STIFFENERS and RESTRAINTS
CONTINUOUS TRACER WIRE
LEEMCO LGV-X00BB VALVE
(SIZE TO IRRIGATION PIPE)
MAINLINE TRACER WIRE
LOOP 3-FEET OF WIRE &
LABEL
FINISH GRADE
GROWING MEDIA
10" ROUND VALVE BOX
8" CORRUGATED PE PIPE
LENGTH AS REQD.
UNDISTURBED SOIL
JOINT RESTRAINTS
CONTINUOUS TRACER WIRE
MAINLINE TRACER WIRE
LOOP 3-FEET OF WIRE &
LABEL
CUT TILE TO
CREATE FLAPS
IRRIGATION LINE
LEEMCO LMV-BBHDSS GATE VALVE
WITH RESTRAINTS AND STIFFENERS
(SIZE TO IRRIGATION PIPE)
MAINLINE PIPE
FINISH GRADE OF GROWING MEDIA
10" ROUND VALVE BOX
FILL TOP PORTION OF VALVE BOX
WITH CLEAN 3/8" CHIP GRAVEL
LASCO SNAPLOK with PVC PIPE
EXTEND 18" FROM VALVE
SWING JOINT - MINIMUM 12" LAY LENGTH
LASCO - BRASS MALE 90 ELL OUTLET
COMPACTED
GROWING MEDIA
TRACER WIRE
12" SPRAY HEAD
TOP OF BED
TOP 6" SHALL BE SOIL
SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS
SERVICE TEE / SADDLE
4" / 6" SPRAY HEAD
TOP OF BED
SERVICE TEE / SADDLE
SWING JOINT
MAXIMUM LENGTH
OF FLEX PIPE - 18"
LATERAL LINE
TOP 6" SHALL BE SOIL
SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS
18" MIN
TOP OF PIPE
18" MIN
TOP OF PIPE
SWING JOINT
MAXIMUM LENGTH
OF FLEX PIPE - 18"
LATERAL LINE
MAINLINE PIPE
TWO-WIRE
CONTROL CABLE
METALLIC TRACER TAPE
PLACE IN TOP 6"
TOP 6" SHALL BE GROWING MEDIA
TRACER WIRE
18" MIN
TOP OF PIPE
DECODER - SINGLE STATION
ZIP TIE TO 36" LENGTH OF
1" PVC PIPE
BURY 12" OF PIPE TO SUPPORT
DECODER OR ZIP TIE TO VALVE BOX
DBR/Y-6 WIRE CONNECTOR
TWO-WIRE PATH
DBR/Y-6 WIRE CONNECTOR
TWO-WIRE PATH
FROM CONTROLLER.
ALLOW 5-FEET SLACK
PER DECODER
ELECTRIC VALVE
LATERAL PE PIPING
MALE INSERT FITTING
2 STAINLESS STEEL CLAMPS on 1.5" and LARGER.
1 STAINLESS STEEL HOSE CLAMP ON 1" PIPE.
6" EXTENTION VALVE BOX - IF REQUIRED
12" RECTANGULAR VALVE BOX
S-80 NIPPLE
MAINLINE PIPE
ID TAG
SUBGRADE
BASE COURSE
SUBGRADE
BASE COURSE
PAVEMENT
TYP.
SLEEVE FOR MAINLINE PIPE
SLEEVE FOR IRRIGATION WIRE
SLEEVE FOR LATERAL PIPE
24" MIN
TOP OF PIPE
24" MIN
TOP OF PIPE
SIDEWALK
EXTEND SLEEVES
2' BEYOND PAVEMENT
MAINLINE SLEEVE
CURB LINE
TYP.
EXTEND SLEEVES
2' BEYOND PAVEMENT
LATERAL SLEEVE
PAVEMENT
TYP.
VALVE BOX
DECODER CABLE FUSE DEVICE
(INLINE, TWO-WAY, THREE-WAY)
2" PVC PIPE USED AS RISER
RE-ENTERABLE CONNECTOR
FOR GROUNDING
LEADS FROM GROUND ROD
AND PLATE
TWO-WIRE CABLES OUT
WIRE SPLICES WITH DBR/Y-6 CONNECTORS
INCOMING TWO-WIRE CABLE
TWO-WIRE CABLE MARKING TAG
NOTCH FOR DCFD LEADS
BRING TOP OF DCFD TO JUST BELOW
BOTTOM OF VALVE BOX LID
12" BURY DEPTH MIN.
6" MIN.
3" MIN.
D 8'
10'
10'
30"
10" ROUND VALVE BOX w/ LID
WELDED CONDUCTOR
TO ROD
BARE #6 SOLID COPPER WIRE
FROM GROUND LUG INSIDE
SATELLITE CONTROLLER OR DECODER
MAXIMUM 12' IN LENGTH.
UNDISTURBED EARTH
5/8" x 8' COPPER CLAD GROUND ROD w/ WELDED CONDUCTOR
DO NOT CUT!
GROUND ROD
(SEE DETAIL)
GROUND ENHANCEMENT MATERIAL
50#s ON TOP OF PLATE and 50#s
ON BOTTOM OF PLATECOPPER GROUND PLATE
4" x 36"
10 AWG SOLID BARE
COPPER WIRES
RE-ENTERABLE TERMINAL
STRIP FOR ALL GROUNDING
CONNECTIONS
VALVE BOX PRE-WELDED CONNECTOR
6" MIN.
GROUND ROD
(SEE DETAIL)
COPPER GROUND PLATE
6 AWG SOLID
COPPER WIRES
TOP VIEW
SIDE VIEWNOTE: GROUNDING PLATE AND ALL OTHER
RELATED MATERIALS BY PAIGE ELECTRIC
CO. OR APPROVED EQUAL.NOT TO SCALE
EARTH GROUNDING
IT IS THE RESPONSIBILITY OF THE INSTALLER TO CONNECT
ALL ELECTRONIC IRRIGATION EQUIPMENT FOR WHICH THEY
ARE RESPONSIBLE TO EARTH GROUND. GROUNDING
COMPONENTS WILL INCLUDE THE ITEMS DESCRIBED IN THE
FOLLOWING PARAGRAPH, AT A MINIMUM.
AT THE VERY MINIMUM, THE GROUNDING CIRCUIT WILL
INCLUDE A COPPER CLAD STEEL GROUND ROD, A SOLID
COPPER GROUND PLATE, AND 100 POUNDS OF GEM EARTH
CONTACT MATERIAL AS DEFINED PER THE FOLLOWING DETAIL.
CONTRACTOR TO PROVIDE WRITTEN VERIFICATION FROM THE
PRODUCT DISTRIBUTOR THAT THE GROUND WAS "MEGGED"
AND THE OHMs ARE WITHIN THE ACCEPTABLE LIMITS.
PLANTING MEDIA
SURVEY RED-TOP MARKER
MARKING SENSOR LOCATION
SOIL SENSOR
WIRE RUN FROM SENSOR TO CONTROLLER
LEAD WIRES FROM SOIL SENSOR
1" PVC SLEEVE
3M DBY WIRE CONNECTOR
#14 AWG DIRECT BURY TRACER WIRE, LABEL END IN VALVE BOX
6" ROUND VALVE BOX
BED GRADE
ROTOR
TOP OF BED
SERVICE TEE / SADDLE
SWING JOINT
MAXIMUM LENGTH
OF FLEX PIPE - 18"
LATERAL LINE
TOP 6" SHALL BE SOIL
SPRINKLER SHALL BE BACKFILLED IN 6" LIFTS
18" MIN
TOP OF PIPE
USE NO PIPE DOPE
USE TEFLON TAPE ONLY ON NPT THREADS
DIAGRAM - THRUST BLOCKS
NTS
NOTE:
ALL PIPING IS TO BE INSTALLED AND TESTED ACCORDING TO
THE MANUFACTURER'S INSTALLATION GUIDELINES.
THRUST BLOCK ALL GASKETED FITTINGS WERE CHANGE OF
DIRECTION OR SOILS REQUIRE BLOCKING.
CONCRETE BLOCKS WILL NOT BE ALLOWED.
ALL THRUST BLOCKS ARE TO BE POURED IN PLACE WITH
CONCRETE TO UNDISTURBED SOILS.
NOTE:
ALL PIPING IS TO BE INSTALLED AND TESTED ACCORDING TO
THE MANUFACTURER'S INSTALLATION GUIDELINES.
THRUST BLOCK ALL GASKETED FITTINGS WERE CHANGE OF
DIRECTION OR SOILS REQUIRE BLOCKING.
CONCRETE BLOCKS WILL NOT BE ALLOWED.
ALL THRUST BLOCKS ARE TO BE POURED IN PLACE WITH
CONCRETE TO UNDISTURBED SOILS.
CONCRETE SLAB
LONG SWEEP ELL
GROUND CONTROLLER PER MANUFACTURERS RECOMMENDATIONS
INCOMING SIGNAL WIRES
LOOP AND BUNDLE
FINISH GRADE
12" RECTANGULAR VALVE BOX
PUMP ENCLOSURE
FRONT OF ENCLOSURE
CONTROLLER MOUNT
POWER FROM INSIDE OF ENCLOSURE
ELECTRICAL CONDUIT FOR CONTROL WIRE
24"
BURY
STATION COMPONENTS:
A PUMP AND MOTOR
B CHECK VALVE
C PRESSURE TRANSDUCER WITH GAUGE
D BY-PASS VALVE
E FLOW SENSOR
F TEMP SENSOR
G MARINE GRADE ALUMINUM BASE (UNPAINTED)
H PUMP INTAKE ISOLATION VALVE
I PUMP DISCHARGE ISOLATION VALVE
J NORMALLY OPEN BFV MASTER VALVE
K MARINE GRADE ALUMINUM ENCLOSURE (UNPAINTED)
L STATION FAN HOOD MOUNTED
M RPZ FEBCO 825 - 2"
N 120V OUTLET FOR IRRIGATION CONTROLLER
O 2" BLOWOUT, WITH THREADED PLUG
P DEAD-FRONT DISCONNECT PANEL
Q OVAL FLANGES FOR NEPTUNE T-10 2" METER
R WYE STRAINER (REQUIRED DOWNSTREAM OF METER)
S EXTRA 1/4 " PORT FOR PSI SENSOR (IRR CONTROLLER)
T BASELINE DECODERS IN PANEL (FLOW DECODER, MV DECODER)
U VFD
NEC CLEARANCE
SEE LOCAL CODES
H
D C
J
E
G
L
K
DETAIL A
F
O
A
B
I
J
M
POWER
DISCONNECT
ENCLOSURE
ENCLOSURE FRONT
P,T
DESCRIPTION OF OPERATION
PUMP STATION WILL START ON A PRESSURE DROP SENSED IN
IRRIGATION MAINLINE. PUMP WILL REGULATE A CONSTANT
DISCHARGE PRESSURE AT VARIABLE FLOW RATE. PUMP WILL
RETIRE BASED UPON A SUSTAIN REGULATE PRESSURE OVER
TIME, AND REDUCTION IN FLOW.
IF IRRIGATION CONTROLLER SENSES UN-SCHEDULED FLOW OR
HIGH FLOW, IRRIGATION CONTROLLER WILL SHUT DOWN PUMP,
AND CLOSE MASTER VALVE.
PUMP STATION SHALL HAVE THE FOLLOWING ALARMS
LOW PRESSURE ALARM
HIGH PRESSURE ALARM
HIGH PUMP VOLUTE TEMP
MOTOR OVERLOAD SHUT DOWN
PHASE LOSS (3-PHZ SYSTEMS ONLY)
VFD FAULT SHUT DOWN
PUMP STATION SPECIFICATIONS:
NAME: 90 NORTH PUMP STATION #1
PUMP STATION TO BE MANUFACTURED BY WATERTRONICS,
PRECISION PUMPING, OR APPROVED EQUAL.
BASIS OF DESIGN: WATERTRONICS WATERMAX 5000
CONTACT ERIC PIFER @ 262-224-3263 FOR PRICING
STATION MODEL: WMBV-5000-7A-3-208-3-50-64
STATION TOTAL PERFORMANCE: 50 GPM @ 25 PSI BOOST
STATIC INLET PRESSURE: 55 PSI
DYNAMIC INLET PRESSURE: 39 PSI
DISCHARGE REGULATE PRESSURE: 64 PSI
PUMP NO.1 3HP (3600 RPM)
PUMP STATION INTAKE CONNECTION SIZE: 2"
PUMP STATION DISCHARGE CONNECTION SIZE:2"
POWER REQUIREMENTS
208V - 3PHZ - 60HZ - 18 FULL LOAD AMPS 17" METER
20" min 10" min
48"
SLAB
ENCLOSURE FRONT
17" METER
12" 52" BASE39"6" 6"
115" SLAB
13"
26"
BASE
9"
48"
SLAB
7"
35"
BASE
6"
FLOW
FLOW
2" FLANGE
CONNECTION TO IRRIGATION
2" RPZ DRAIN
TO GROUND SURFACE OR DRAIN
IRRIGATION CONTROLLER
MOUNTED BY CONTRACTOR
N
K
G
Q
R 4938"
U
S
24"
FLOW
CONNECTION BY CIVIL
CONTRACTOR
CONTINUED BY IRRIGATION
CONTRACTOR
24"O
DETAIL "A"
CONCRETE ANCHOR
TYPICAL
POWER
CONDUIT
FROM
UTILITY
REAR of ENCLOSURE
FLOW
IRRIGATION CONTROLLER
1-1/2"
CONDUIT
LI-501
IRRIGATION BOOSTER PUMP
STATION #1
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
K
Q
BC
N
PRESSURE
0 160
VFD
J IJ
A
E
F
E
D
G
R
VFD
RPZ DRAIN LINE TO
GROUND SURFACE OR DRAIN BY OTHERS
3" FLG
STATION COMPONENTS:
A PUMP AND MOTOR
B CHECK VALVE
C RPZ FEBCO MODEL# 880V-3"
D PRESSURE TRANSDUCER WITH GAUGE
E PRESSURE GAUGE LIQUID FILLED
F FLOW SENSOR
G NORMALLY OPEN BFV MASTER VALVE
H MARINE GRADE ALUMINUM BASE (UNPAINTED)
I STATION FAN HOOD MOUNTED
J MARINE GRADE ALUMINUM ENCLOSURE (UNPAINTED)
K DISCHARGE DROP PIPE W/ 3" FLG CONNECTION
L 120V OUTLET FOR IRRIGATION CONTROLLER
M OVAL FLANGES FOR NEPTUNE T-10 2" METER
N BY PASS VALVE
O BLOWOUT WITH PLUG
P DEAD FRONT DISCONNECT BOX
Q PUMP INTAKE ISOLATION VALVE
R PUMP DISCHARGE ISOLATION VALVE
S BASELINE DECODERS IN PANEL (FLOW DECODER, MV DECODER)
T 3" WYE STRAINER (REQUIRED DOWNSTREAM OF METER)
U EXTRA 1/4 " PORT FOR PSI SENSOR (IRR CONTROLLER)
DETAIL A
POWER
DISCONNECT
ENCLOSURE
STATION ENCLOSURE FRONTSTATION ENCLOSURE FRONT
NEC CLEARANCE
SEE LOCAL CODES
HH
P
17" METER
20" min
ENCLOSURE FRONT
26"
BASE
10" min
17" METER
FLOW
49 316"
IRRIGATION CONTROLLER
MOUNTED BY CONTRACTOR
6"52" BASE17"52" BASE12"39" BASE6"
184" SLAB
H
J
L
M
S
T
U
6"
3" FLANGE
CONNECTION TO IRRIGATION
PUMP STATION SPECIFICATIONS:
NAME: 90 NORTH PUMP STATION #2
PUMP STATION TO BE MANUFACTURED BY WATERTRONICS,
PRECISION PUMPING, OR APPROVED EQUAL.
BASIS OF DESIGN: WATERTRONICS WATERMAX 5000
CONTACT ERIC PIFER @ 262-224-3263 FOR PRICING
STATION MODEL: WMBV-5000-7A-5-208-3-100-60
STATION TOTAL PERFORMANCE: 100 GPM @ 25 PSI BOOST
STATIC INLET PRESSURE: 55 PSI
DYNAMIC INLET PRESSURE: 35 PSI
DISCHARGE REGULATE PRESSURE: 60 PSI
PUMP NO.1 5HP (3600 RPM)
PUMP STATION INTAKE CONNECTION SIZE: 2"
PUMP STATION DISCHARGE CONNECTION SIZE:2"
POWER REQUIREMENTS
208V - 3PHZ - 60HZ - 21 FULL LOAD AMPS
48"
SLAB35"
BASE
DESCRIPTION OF OPERATION
PUMP STATION WILL START ON A PRESSURE DROP SENSED IN
IRRIGATION MAINLINE. PUMP WILL REGULATE A CONSTANT
DISCHARGE PRESSURE AT VARIABLE FLOW RATE. PUMP WILL
RETIRE BASED UPON A SUSTAIN REGULATE PRESSURE OVER
TIME, AND REDUCTION IN FLOW.
IF IRRIGATION CONTROLLER SENSES UN-SCHEDULED FLOW OR
HIGH FLOW, IRRIGATION CONTROLLER WILL SHUT DOWN PUMP,
AND CLOSE MASTER VALVE.
PUMP STATION SHALL HAVE THE FOLLOWING ALARMS
LOW PRESSURE ALARM
HIGH PRESSURE ALARM
HIGH PUMP VOLUTE TEMP
MOTOR OVERLOAD SHUT DOWN
PHASE LOSS (3-PHZ SYSTEMS ONLY)
VFD FAULT SHUT DOWN
DETAIL "A"
CONCRETE ANCHOR
TYPICAL
POWER
CONDUIT
FROM
UTILITY
REAR of ENCLOSURE
FLOW
15"
CONNECTION BY CIVIL
CONTRACTOR
CONTINUED BY IRRIGATION
CONTRACTOR
24"24"O
IRRIGATION CONTROLLER
1-1/2"
CONDUIT
LI-502
IRRIGATION BOOSTER PUMP
STATION #2
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park site design group, ltd. Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
ISSUANCES
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
C-2
POC-2
BFPP2
Wx
B
A
736 735
734734
733 732
733734
8 73
PR
O G R
ESS PAR
KW
AY (TW
O W
AY)
PARK
SIDE
DRIV
E (TW
O WAY)
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
6"/2"sl
3"sl
3"sl
3"sl
3"sl
6"/2"sl
6" /2
"s l
6"/2"sl
3"sl
6"/2"sl
3"sl
4"sl
3"sl 3"sl
6"/2"sl
3" sl
3"sl
8" /2
"s l
8"/2"sl
4" sl
3" sl
6" /2
"s l
3"sl
4"sl
4"sl
3"sl 3"sl
4"sl
4"sl
3"sl
6"/2"sl
6"/2"sl
6"/2"sl
3"/1"sl
G
S2
S2
S2
S2
S2
G
G
G
G
G
G
4"sl 4"sl
SMS
SMS
G
Wx
LEGEND
TWO-WIRE PATH ROUTE
WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow
TWO-WIRE PATH ROUTE
WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red
SLEEVE - (BORING REQUIRED) - Size per Plan
SLEEVE - Size per Plan
PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE
PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE
MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN
OPEN SKY ON THE PUMP ENCLOSURE.
INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)
BASELINE SOIL MOISTURE SENSOR
S2
S1
SMS
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park
Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
M
AT
C H L
IN
E
LI
-7
M
AT
C H L
IN
E
LI
-7
LI-700
TWO-WIRE SCHEMATIC
ENLARGEMENT A
TWO-WIRE SCHEMATIC ENLARGEMENT A
POC-1
C-1
BFPP1
Wx
732 732
S2
S2
PAR
KSID
E DR
IVE (
TWO W
AY)
LANDM
ARK DRIVE (TW
O W
AY)
4"sl
3"sl
3"sl
4"sl
4"sl
3"sl
4" /2
"s l
3"sl
4"sl
3"sl
6" /2
"s l
3"sl
3"sl
G
G
G
G
G
INSTALL 2ND TWO-WIRE DECODER
WIRE IN A 10" VALVE BOX FOR
FUTURE USE. PROTECT ENDS.
G
SMS
4"/4"sl
Wx
LEGEND
TWO-WIRE PATH ROUTE
WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow
TWO-WIRE PATH ROUTE
WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red
SLEEVE - (BORING REQUIRED) - Size per Plan
SLEEVE - Size per Plan
PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE
PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE
MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN
OPEN SKY ON THE PUMP ENCLOSURE.
INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)
BASELINE SOIL MOISTURE SENSOR
S2
S1
SMS
LI-701
TWO-WIRE SCHEMATIC
ENLARGEMENT B
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park
Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
M
AT
C H L
IN
E
LI
-7
M
AT
C H L
IN
E
LI
-7
M
AT
C H L
IN
E
LI
-7
M
AT
C H L
IN
E
LI
-7
TWO-WIRE SCHEMATIC ENLARGEMENT B
729 728
S2
AR
BO
R D R
IVE (TW
O W
AY)
PARKSIDE DRIVE (TWO WAY)
3" sl
3" sl
4" /2
"s l
G
G
3" sl
Wx
LEGEND
TWO-WIRE PATH ROUTE
WIRE PATH #1 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Yellow
TWO-WIRE PATH ROUTE
WIRE PATH #2 - #14 AWG Maxi-Wire for Baseline Decoder Systems - Red
SLEEVE - (BORING REQUIRED) - Size per Plan
SLEEVE - Size per Plan
PAIGE DECODER CABLE FUSE DEVICE (DCFD) - INLINE
PAIGE DECODER CABLE FUSE DEVICE (DCFD) TWO-WAY
PRECIPITATION SENSOR --
PRECIPITATION SENSOR -- BASELINE TIPPING BUCKET RAIN GAUGE
MODEL #BL-5407-KIT ; INSTALL PER MANUFACTURER'S DIRECTIONS IN
OPEN SKY ON THE PUMP ENCLOSURE.
INSTALL BIRD SPIKES ON UPPER EDGE OF GAUGE (4"Ø)
BASELINE SOIL MOISTURE SENSOR
S2
S1
SMS
LI-702
TWO-WIRE SCHEMATIC
ENLARGEMENT C
Date Issued
Sheet Title:
Drawing Number:
Progress Parkway, Schaumburg, IL 60173
Schaumburg 90 NDW Urban Park
Landscape Architect 888 South Michigan Avenue #1000, Chicago, IL 60605
p. 312.427.7240 w. www.site-design.com
V3 Companies Engineer 7325 Janes Avenue, Woodridge, IL 60517
p. 630.724.9200 w. www.v3co.com
Rev. #
File :
Approved :
Drawn :
Project No :
Scale : AS NOTEDChecked :
90N Park Irrigation.dwg
08/04/202301 Phase 2 External Irrigation
DF
MZ
DF
Description
M
AT
C H L
IN
E
LI
-7
M
AT
C H L
IN
E
LI
-7
TWO-WIRE SCHEMATIC ENLARGEMENT C
File details come from the government source that posted it. Updated .