IRD26019-EXTSIGN-specsVol2.pdf

PDF 12 MB Posted

Attached to
Sussex Central High School - C-1 Exterior Signage
Solicitation number
IRD26019-EXTSIGN
Issued by
Sussex County, Delaware

About this file

This document is a comprehensive exterior signage and wayfinding bid package for Sussex Central High School, developed by Cloud Gehshan Design and dated October 3, 2025. The project involves designing and fabricating a complete exterior signage system for the school, including 28 total signs across multiple categories such as gateway identification, building identification, vehicular directional signs, and athletic logos. The sign types range from small wall-mounted signs to larger canopy-mounted and gateway signs, with specific design intent focused on creating a cohesive visual communication system throughout the campus.

The bid package includes detailed technical specifications covering materials, colors, typography, fabrication requirements, and installation guidelines. Key specifications include using Source Serif and Source Sans typography, a specific color palette featuring SCHS Blue and Yellow, and materials like precast concrete, brick, and aluminum with specific finish requirements. The document outlines rigorous performance standards, including warranty provisions, surface finish requirements, and precise installation instructions. Fabricators are required to submit detailed shop drawings, samples, and engineering documentation, with an emphasis on durability, vandal resistance, and compliance with ADA and local sign codes. The project requires a high level of precision in design execution, with specific guidelines for message layout, material preparation, and installation techniques.

View the file

Other files

File Type Posted
IRD26019-EXTSIGN-ad1.pdf PDF
IRD26019-EXTSIGN-rfp.pdf PDF
IRD26019-EXTSIGN-wages.pdf PDF
IRD26019-EXTSIGN-specsVol1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exterior Signage and Wayfinding

Bid Document October 03, 2025

Basic Standards Art, color, material and typography specifications

Sign System Overview Placement, design, and scale of signs

Design Intent Sign elevations, graphic layouts and construction details

Sign Location & Message Schedule Explanation of wayfinding strategy and sign placement criteria

Performance Specifications Sign performance, quality assurance and execution requirements

Appendix Appendix

Table of Contents

4.0

5.0

6.0

1.0

2.0

3.0

Section 1 Basic Standards

1.1 Page Number

Client/Project Project No.

Date Revisions Scale

© 2025 Cloud Gehshan Design

Sussex Central High School Exterior Signage and Wayfinding

10.03.25

BSA339001

N/A 1.2 Page Number

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Typography

Basic Standards

F1 – �Source Serif Semibold

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890 &!?,.”

F4 – �Source Sans Semibold (600)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890 &!?,.”

F5 – �Source Sans Bold (700)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890 &!?,.”

F3 – �Source Sans Medium (500)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890 &!?,.”

F2 – �Source Sans Regular (400)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890 &!?,.”

Typographic Standards

Notes No substitute typefaces will be accepted.

Typefaces are available from:

Adobe Systems Inc.

(adobe.com/type) Google Fonts (fonts.google.com)

© 2025 Cloud Gehshan Design

Sussex Central High School Exterior Signage and Wayfinding

10.03.25

BSA339001

N/A 1.3 Page Number

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

SCHS BlueP1

SCHS YellowP2

Commodore

Anchors Aweigh

Goldfinch

P3

P13

P4

Hex #0055B0

Hex #FFD700

SW 6524

SW 9179

SW 6905

Matthews Acrylic Polyurethane Paint, Satin Finish Topcoat with 290 228Sp Super Satin Clear coat

Matthews Acrylic Polyurethane Paint, Satin Finish Topcoat with 290 228Sp Super Satin Clear coat

Sherwin Williams Exterior Acrylic Latex Paint Topcoat with 290 228Sp Super Satin Clear coat (or equivalent)

Sherwin Williams Exterior Acrylic Latex Paint Topcoat with 290 228Sp Super Satin Clear coat (or equivalent)

Sherwin Williams Exterior Acrylic Latex Paint Topcoat with 290 228Sp Super Satin Clear coat (or equivalent)

Sherwin Williams Exterior Acrylic Latex Paint Topcoat with 290 228Sp Super Satin Clear coat (or equivalent)

Sherwin Williams Exterior Acrylic Latex Paint Topcoat with 290 228Sp Super Satin Clear coat (or equivalent)

BiscuitP5 SW 6112

Pewter S11P6 Match to Fabral Pewter S11 Matthews Acrylic Polyurethane Paint, Satin Finish Topcoat with 290 228Sp Super Satin Clear coat

Iron OreP10 SW 7069

Shadow fillP12 Base color: Transparent Gray (LC 4024) Clear coat: Clear (LC 4004)

Lithichrome Stone Paint Clear coat to be re-applied every 4-5 years

Number Color Specification Paint or CoatingPaint Matches

Colors

Basic Standards

Color Standards

Color Schedule Paints

- Matthews paint products are specified for exterior signage and display hardware and related elements.

- Gloss finish of paint specified is to be 60 degrees or 29.8 on a 60 degree glossimeter. Refer to performance requirements of exact specifications.

- All acrylic polyurethane finishes require final clear coat finish.

PPG Architectural Finishes, Inc.

888.774.7732 www.ppghpc.com Matthews Paint Company 800.323.6593 www.matthewspaint.com SprayLat Powder Coatings 940.665.9590 www.spraylat.com Sherwin Williams 888.774.7732 sherwin-williams.com

© 2025 Cloud Gehshan Design

Sussex Central High School Exterior Signage and Wayfinding

10.03.25

BSA339001

N/A 1.4 Page Number

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Precast ConcreteM1

Brick WallM2

AluminumM3

Reading Rock RockCast Masonry Veneer, Charlotte Tan

Continental #416 (Velour) Econo size

Horizontally brushed finish

Match to architectural finish

Match to architectural finish

Topcoat with 290 228Sp Super Satin Clear coat

Number Material Specification Fabrication ProcessCustom Matches

Materials

Basic Standards

Material Standards

Vendor Information

Reading Rock, Inc 800.482.6466 readingrock.com

© 2025 Cloud Gehshan Design

Sussex Central High School Exterior Signage and Wayfinding

10.03.25

BSA339001

N/A 1.5 Page Number

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Artwork

S1 Parking

Symbols

CL

CL

CL

CL

CL

CL

Arrows

S1 Directional Arrow

A1 Golden Knights A2 SC Logo A3 FFA Logo

Symbols

Basic Standards

Graphic Standards

Arrows & Symbols Notes The graphic element(s) shown on this page have been carefully created, sized and spaced.

Artwork for these element(s) will be provided to the fabricator as electronic, digital files.

FABRICATOR MUST USE ARTWORK

SUPPLIED; NO SUBSTITUTE ARTWORK

OR TYPESETTING WILL BE ACCEPTED.

alt:

The type layouts for this project have been carefully created, sized and spaced.

Section 2 Sign System Overview

2.1

Date Scale

10.03.25 2.2 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Sign Type Overview

2'

0'

4'

6'

8'

10'

12'

14'

16'

High �chool�

High �chool�

GW1

Gateway ID

VD2b Vehicular Directional Medium

VD3a Vehicular Directional Small Single Faced

VD3a Vehicular Directional Small Single Faced

VD3b Vehicular Directional Small Double Faced

VD3b Vehicular Directional Small Double Faced

3/8" = 1'

Sign Type Overview

Further detail for individual sign types is included in section 3

10.03.25 2.3 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Sign Type Overview

2'

0'

4'

6'

8'

10'

12'

14'

16'

BID1a Building ID Canopy-mounted

BID1b Building ID Canopy-mounted

� � �� � � � ��� � �� � � � ��� � �� � � � �� � � � � � �� � ���� � � � �� � ���� � � � �� � ��10 1/2"

2'-6"

3/8" = 1'

10.03.25 2.4 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Sign Type Overview

2'

0'

4'

6'

8'

10'

12'

14'

16'

18'

20'

22'

24'

26'

BID3

Building ID Wall-mounted

BID2a Building ID Wall-mounted

BID2b Building ID Wall-mounted

BID2c Building ID Wall-mounted

BID2d Building ID Wall-mounted

2'-8 1/2"

1'-3"

1'-3"10 1/2" 10 1/2"

1'-10"

1'-3 1/2"

3/16" = 1'

10.03.25 2.5 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Sign Type Overview

2'

0'

4'

6'

8'

10'

12'

14'

16'

BID4a Athletics Logo Wall-mounted

BID4b Athletics Logo Wall-mounted

6'-10 3/4"10'-6"

3/8" = 1'

Section 3 Design Intent

3.1

10.03.25 3.2 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – GW1 scale: 1/2" = 1'-0"1 Side View scale: 1/2" = 1'-0"3

Plan scale: 1/2" = 1'-0"2

NOTE:

UPLIGHTING TO BE COORDINATED

WITH ELECTRIC ENGINEER

Rear Elevation scale: 1/2" = 1'-0"4

6'-10"

5'-2"

P12

P12

M1

M2

P12

P10

1'-8"

1'-11 1/4" 9'-6 11/16"

9'-6 11/16"

1'-11 1/4"

GW1 – Gateway ID

Note:

Only the GW1 sign type is to be illuminated, but externally via up-lighting. Light specification and detailing to be coordinated by other project trades, not the sign vendor.

Additional sign location/placement information to be documented on the civil/landscape drawings in order to ensure no conflicts with conduits included in the new project. A utility mark-out will need to be called in by the sign fabricator prior to any digging/excavation on site for purposes of installing footers/ structures.

10.03.25 3.3 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – GW1 scale: 1/2" = 1'-0"1 Side View scale: 1/2" = 1'-0"3

Layout scale: 1/2" = 1'-0"4

Plan scale: 1/2" = 1'-0"2

6'-0"

6'-10"

10"

5'-2"

8'-7 1/2"

F1

F1

F4

F4

1'-8"

8'-7 1/2" 6"

4 1/4"

4"

2 1/4"

5/16"

Precast concrete top. Fabricator to provide concrete color samples for approval to match architectural finish. Sides to inset 1” deep. Carved (or molded) and shadow filled school and entrance name. Cutout letters for address to be flush mounted to the surface.

Brick veneer wall cladding. Fabricator to provide samples to match architectural finish. Brick walls to be glued or clipped to internal structure.

Uplighting to wash sign face at night. To be coordinated with landscape.

Distance from the sign face to be determined to receive lighting evenly.

1/4” thick cutout letters for address to be flush mounted to the surface.4

4"4"

1'-3 1/4"

1'-9 1/4"

1'-11 1/4" 9'-6 11/16"

5 5/8" 5 5/8"

9'-6 11/16"

5 5/8" 5 5/8"

1'-3 1/4"1'-11 1/4"

4"

4"

5 1/4"

6 3/4"

6 3/4"

9 1/4"

10"

9 1/2"

5'-2 1/16"

1"1"

1"

1"1"

1"

1"

GW1 – Gateway ID

Note:

Full-size vector artwork will be issued to the awarded fabricator for production purposes.

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable.

10.03.25 3.4 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Longitudinal Section – GW1 scale: 1/2" = 1'-0"1 Side Section scale: 1/2" = 1'-0"3

Plan Section scale: 1/2" = 1'-0"2

Internal structure option 1 – Ivany Block (or CMU Block)

Side View scale: 1/2" = 1'-0"4

Typical Side Section Detail – Cutout Letters scale: 3" = 1'-0"5

1/4"

5'-2"

1'-8"

Precast concrete top. Fabricator to provide concrete color samples for approval to match architectural finish. Sides to inset 1” deep. Carved (or molded) and shadow filled school and entrance name. Cutout letters for address to be flush mounted to the surface.

Masonry wall with Ivany Block (or CMU Block) concrete core and reinforced steel bar structure, grout solid with concrete, clad with specified brick veneer wall.

Brick veneer wall cladding. Fabricator to provide samples to match architectural finish. Brick walls to be glued or clipped to internal structure.

Fabricator to provide engineer stamped concrete foundation and structure.

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in precast concrete wall, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Water-jet/router cut 1” thick aluminum artwork, with short-grain horizontally brushed finish and super-satin clear coat

1'-3 1/4"

1'-11 1/4"

4"4"

3 5/8" 3 5/8" 8"

8'-7 1/2"EQ EQ

9'-6 11/16"

8"

3 5/8"

3 5/8"

1'-3 1/4"1'-11 1/4"

1"

1"

1"

1"

8'-7 1/2"EQ EQ

9'-6 11/16"

1"

3 5/8" 3 5/8" 8'-11 7/16"

2 3/4"

3 5/8" 3 5/8"

6'-0"

10”

1”

1”

1'-9 1/4"

5'-2"

1'-8"

1'-3 1/4"

1'-11 1/4"

4"4"

3 5/8" 3 5/8" 8"

1'-9 1/4"1'-9 1/4"

GW1 – Gateway ID

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing

10.03.25 3.5 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Longitudinal Section – GW1 scale: 1/2" = 1'-0"1 Side Section scale: 1/2" = 1'-0"3

Plan Section scale: 1/2" = 1'-0"2

Internal structure option 2 – Poured Concrete

Side View scale: 1/2" = 1'-0"4

Typical Side Section Detail – Cutout Letters scale: 3" = 1'-0"5

1/4"

5'-2"

1'-8"

Precast concrete top. Fabricator to provide concrete color samples for approval to match architectural finish. Sides to inset 1” deep. Carved (or molded) and shadow filled school and entrance name. Cutout letters for address to be flush mounted to the surface.

Masonry wall with poured concrete and reinforced steel bar structure, grout solid with concrete, clad with specified brick veneer wall.

Brick veneer wall cladding. Fabricator to provide samples to match architectural finish. Brick walls to be glued or clipped to internal structure.

Fabricator to provide engineer stamped concrete foundation and structure.

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in precast concrete wall, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Water-jet/router cut 1” thick aluminum artwork, with short-grain horizontally brushed finish and super-satin clear coat

1'-3 1/4"

1'-11 1/4"

4"4"

3 5/8" 3 5/8" 8"

8'-7 1/2"EQ EQ

9'-6 11/16"

8"

3 5/8"

3 5/8"

1'-3 1/4"1'-11 1/4"

1"

1"

1"

1"

8'-7 1/2"EQ EQ

9'-6 11/16"

1"

3 5/8" 3 5/8" 8'-11 7/16"

2 3/4"

3 5/8" 3 5/8"

6'-0"

10”

1”

1”

1'-9 1/4"

5'-2"

1'-8"

1'-3 1/4"

1'-11 1/4"

4"4"

3 5/8" 3 5/8" 8"

1'-9 1/4"1'-9 1/4"

GW1 – Gateway ID

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing

10.03.25 3.6 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – VD2b scale: 1/2" = 1'-0"1

Plan scale: 1/2" = 1'-0"2

Rear scale: 1/2" = 1'-0"4Side scale: 1/2" = 1'-0"3

3'-9"

8'-0"

P10

P10

P5

P3

P4

P13

P13

BID4b

7'-0"

8'-0"

2'-0"

2'-7"

6'-0"

5 11/16"

VD2b – Vehicular Directional-Medium

Note:

Layout guidelines for sign type VD2b is shown on page 3.7. The awarded fabricator will be required to produce layout proofs for all sign locations based on the provided guidelines and message schedule included in section 4. Layout proofs will be reviewed by the design team prior to approval for production.

10.03.25 3.7 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Plan scale: 1/2" = 1'-0"2 Section View scale: 1 1/2" = 1'-0"5

Elevation – VD2b scale: 1/2" = 1'-0"1 Rear scale: 1/2" = 1'-0"4Side scale: 1/2" = 1'-0"3

Layout scale: 1/2" = 1'-0"6

3’ 9”

6"

5 1/2" 5"5 1/4"

5"

5 1/2"

5'-5 1/2"

5'-7 1/4"

4 3/4"

3'-4"

3'-9"

2 1/2" 2 1/2"

2'-0"

8'-0"

1'-10 1/2"

3'-0"

7'-0"

8'-0"

3/16” thick painted aluminum panel with direct print message on first surface and graphic on second surface.

Mask and spray background colors.

Aluminum C-channel to be welded to back side of the panel to be attached to posts.

6” x 5 1/2” x 1/4” wall C-channel cu� to cover mounting clip.

Mechanically fastened with fasteners painted to match.

5”x5” painted aluminum extrusion 3

Matchplate footer details to be engineered and provided for approval, sign fabricator to provide engineered foundation details sealed by a certified engineer, verify existing conditions in field and inform designer and client of any issues that will a�ect design intent.

5 1/2” x 5 1/4” x 1/4” wall C-channel welded to message panel.

Mechanically fastened to 5” x 5” tube.

4" 4"

3'-4"

3 1/4" typ.

5" typ.

5" typ.

9 3/4" typ.

7" typ.

5" typ.

1 9/16"

1'-7 3/4"

2'-1 1/2"

5 1/2"

6" 6"

5 11/16"

2'-7"

5 1/4"

5 1/2"

5 11/16"

10 1/2" typ.

7" typ.

7" typ.

5" typ.

3/16"

VD2b – Vehicular Directional-Medium

10.03.25 3.8 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Matchplate Installation Detail - VD2b scale: 3" = 1'-0"1

Plan View scale: n.t.s.2

Axo Exploded View scale: n.t.s.3 varies from 4-6" minimum 3"

15"

15"

Painted extruded aluminum tube upright w/ super satin clear coat.

Stainless steel through bolts.2

Aluminum baseplate welded to upright w/ super satin clear coat.

Fabricator to engineer plate thickness.

Stainless steel leveling washers.4

Aluminum matchplate welded to anchor tube w/ Te�on coating or equivalent to prevent corrosion. Fabricator to engineer plate thickness.

Extruded alum anchor tube w/ Te�on coating or equivalent to prevent corrosion. 6

Poured concrete footer (fabricator to engineer footer size).7

Back�ll to match grade conditions.8

Cut hole in base plate for water drainage.9

VD2b – Vehicular Directional-Medium

10.03.25 3.9 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – VD3a scale: 1/2" = 1'-0"1 Rear scale: 1/2" = 1'-0"4

Plan scale: 1/2" = 1'-0"2

Sussex Central Farm

Side scale: 1/2" = 1'-0"3

2'-7"

P5

P10

P10 2'-2"

2'-0"

4'-2"

3'-4 1/2"

4'-0"4'-2"

P13

5 3/4"

VD3a – Vehicular Directional-Small, Double Faced

Note:

Layout guidelines for sign type VD3a is shown on page 3.10. The awarded fabricator will be required to produce layout proofs for all sign locations based on the provided guidelines and message schedule included in section 4. Layout

10.03.25 3.10 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Side scale: 1/2" = 1'-0"3

Plan scale: 1/2" = 1'-0"2 Section View scale: 1 1/2" = 1'-0"5

2'-7"

Elevation – VD3a scale: 1/2" = 1'-0"1 Rear scale: 1/2" = 1'-0"4

High �chool�

Layouts scale: 1/2" = 1'-0"5

High �chool�

3’ 4 1/2”

5"5 1/4"

5"

5 1/2"

2'-2"

4'-0"4'-2"

5" typ.

3" typ.2'-2"

2'-0"

4'-2"

3'-4 1/2"

3/16” thick painted aluminum panel attached to posts. Message to be direct print.

5”x5” painted aluminum extrusion2

C-channel cu� to be welded to back of message panel. Mount to posts with tamper-proof counter-sunk screws

Matchplate footer details to be engineered and provided for approval, sign fabricator to provide engineered foundation details sealed by a certified engineer, verify existing conditions in field and inform designer and client of any issues that will a�ect design intent.

4 3/4" 5" typ.

9 1/4" typ.

6 3/4" typ.

5" typ.

1'-6"

3/16"

5"

5 1/4"5 7/16"

5 7/16"

VD3a – Vehicular Directional-Small, Double Faced

10.03.25 3.11 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Matchplate Installation Detail - VD2b scale: 3" = 1'-0"1

Plan View scale: n.t.s.2

Axo Exploded View scale: n.t.s.3 varies from 4-6" minimum 3"

15"

15"

Painted extruded aluminum tube upright w/ super satin clear coat.

Stainless steel through bolts.2

Aluminum baseplate welded to upright w/ super satin clear coat.

Fabricator to engineer plate thickness.

Stainless steel leveling washers.4

Aluminum matchplate welded to anchor tube w/ Te�on coating or equivalent to prevent corrosion. Fabricator to engineer plate thickness.

Extruded alum anchor tube w/ Te�on coating or equivalent to prevent corrosion. 6

Poured concrete footer (fabricator to engineer footer size).7

Back�ll to match grade conditions.8

VD3a – Vehicular Directional-Small, Double Faced

10.03.25 3.12 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – VD3b scale: 1/2" = 1'-0"1 Rear scale: 1/2" = 1'-0"4

Plan scale: 1/2" = 1'-0"2

High �chool�

High �chool�

Side scale: 1/2" = 1'-0"3 Alt layout for lots scale: 1/2" = 1'-0"5

Lot 3

2'-7"

P5

P10

P10 2'-2"

2'-0"

4'-2"

3'-4 1/2"

4'-0"4'-2"

P13

5 7/8"

VD3b – Vehicular Directional-Small, Single Faced

Note:

Layout guidelines for sign type VD3b is shown on page 3.13. The awarded fabricator will be required to produce layout proofs for all sign locations based on the provided guidelines and message schedule included in section 4. Layout

10.03.25 3.13 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Elevation – VD3b scale: 1/2" = 1'-0"1 Rear scale: 1/2" = 1'-0"4

High �chool�

High �chool�

Layouts scale: 1/2" = 1'-0"5

Lot 3

High �chool�

Side scale: 1/2" = 1'-0"3

Plan scale: 1/2" = 1'-0"2 Section View scale: 1 1/2" = 1'-0"5

5 1/2"

2'-7"

3’ 4 1/2”

6"

5 1/2"

5"5 1/4"

5"

5 1/2"

5" typ.

3" typ.

2'-2"

2'-0"

4'-2"

3'-4 1/2"

4 3/4" 5" typ.

9 1/4" typ.

5" typ.

5" typ.

4 3/4" 5" typ.

9 1/4" typ.

9 1/4" typ.

6 3/4" typ.

5" typ.

2'-2"

4'-0"4'-2"

5 1/2"

1'-6"

3/16” thick painted aluminum panel attached to posts. Message to be direct print.

5”x5” painted aluminum extrusion2

C-channel cu� to be welded to back of message panel. Mount to posts with tamper-proof counter-sunk screws

Matchplate footer details to be engineered and provided for approval, sign fabricator to provide engineered foundation details sealed by a certified engineer, verify existing conditions in field and inform designer and client of any issues that will a�ect design intent.

5 7/8"

5 7/8"

3/16"

3/16"

5 7/8"

VD3b – Vehicular Directional-Small, Single Faced

10.03.25 3.14 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Matchplate Installation Detail - VD2b scale: 3" = 1'-0"1

Plan View scale: n.t.s.2

Axo Exploded View scale: n.t.s.3 varies from 4-6" minimum 3"

15"

15"

Painted extruded aluminum tube upright w/ super satin clear coat.

Stainless steel through bolts.2

Aluminum baseplate welded to upright w/ super satin clear coat.

Fabricator to engineer plate thickness.

Stainless steel leveling washers.4

Aluminum matchplate welded to anchor tube w/ Te�on coating or equivalent to prevent corrosion. Fabricator to engineer plate thickness.

Extruded alum anchor tube w/ Te�on coating or equivalent to prevent corrosion. 6

Poured concrete footer (fabricator to engineer footer size).7

Back�ll to match grade conditions.8

VD3b – Vehicular Directional-Small, Single Faced

10.03.25 3.15 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

West Elevation – BID1a scale: 1/4" = 1'-0"1 South Elevation – BID1a scale: 1/4" = 1'-0"2

Lockups scale: 1/4" = 1'-0"3

M3 M3 P6P6

10 1/2"

10 1/2" 10 1/2"

10 1/2"

10'-1 3/8" (+/-)

12'-8 1/8" (+/-)

9'-0 3/4" 2"

BID1a – Building ID, Canopy-mounted

Note:

Details for canopy attachment are shown on page 3.16. The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector artwork will be issued to the awarded fabricator for production purposes.

10.03.25 3.16 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat.

3/16” thick aluminum letter back, router cut to shape of artwork2

2“ brake formed tab3

Brake form line4

Countersunk set screws5

2” x 2”, 1/4” thick aluminum square tube6

Canopy Support ‘I’ beam by others7

TYP.

2'-0"

B/ CANOPY

9'-6"

7'- 2 1

/2" 2'-

3 1 /2"

9'- 7 1

/2"

T/ STL BEAM

10'-9 1/2"

1'-4"

1'-8 5/8"

Wall Section - Gymnasium Area E scale: 3/8" = 1'-0"1 Section - Letter Detail at Canopy scale: 1 1/2" = 1'-0"2

8"

MAX 5'-0" PROJECTION

SEE PLAN

Typical – Partial Axo N.T.S.3

2"

2"

10 1/2"

2"

BID1a – Building ID, Canopy-mounted

10.03.25 3.17 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Lockups scale: 1/4" = 1'-0"2

West Elevation – Performing Arts Lobby Area H scale: 1/4" = 1'-0"1

M3 P6

2'-6"

3 1/2"

2'-6"

26'-7 13/16"

2'-6"

16'-7" (+/-)

BID1b – Building ID, Canopy-mounted

Note:

Details for canopy attachment are shown on page 3.18. The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.18 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Armature Sim locations scale: 1/4" = 1'-0"4

Wall Section - Performing Arts Lobby Area H scale: 3/8" = 1'-0"1

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat.

Threaded stud boss2

Aluminum channel letter return3

Butyl sealant4

1” SS fender washer5

Butyl sealant6

Lock nut7

3/8” diameter hole, Typ8

HSS 1 1/2” x 1 1/2” x 1/8”9

HSS 1 1/2” x 1 1/2” x 1/8” horizontal rail10

H10.4

8 1/4"

3"

DIMENSIONAL CHARACTER,

PROFILE VARIES

SIGN ARMATURE SIM

A6/A-312 EXCEPT AS NOTED

'-0

T.O. BLK'G.

B.O. SIGN

T.O. SIGN

H10.4

3'-7 3/4"

3'-2 1/2"

Section - Letter Detail at Canopy scale: 1" = 1'-0"2

Fabricated Channel Letter Detail scale: 1" = 1'-0"3

2'-6"

2'-6"

3 1/2"

7"

BID1b – Building ID, Canopy-mounted

10.03.25 3.19 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

North Elevation – Middle School Entrance - BID2a scale: 1/4" = 1'-0"1

Lockups – BID2a scale: 1/4" = 1'-0"3

1'-10"

1/2"

1/2"

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat

Threaded stud is secured to aluminum backer with nuts2

Tamper-resistant, countersunk fasteners 3

Internal aluminum angle framing stitch-welded to aluminum channel

1/2”thick aluminum spacer5

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in mortar between bricks, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Existing brick masonry wall, fabricator to verify existing conditions prior to final shop drawings

Typical Side Section Detail – BID2a scale: 3" = 1'-0"2

EQ EQ

1'-10"

1'-3 1/2"

20'-0 1/4" (+/-)

1'-10 1/16"

1'-3 1/2" 2'-3 3/8"

1'-3 1/2"

3"

2"

3"

2"

BID2a – Building ID, Wall-mounted

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.20 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

West Elevation – Gym Area D - BID2b scale: 1/4" = 1'-0"1

Lockups – BID2b scale: 1/4" = 1'-0"2

Wall Section - Area D scale: 3/8" = 1'-0"3

LEVEL 1

0' - 0"

TRACK LEVEL

12' - 0"

2'-0"

Typical Side Section Detail – BID2b scale: 3" = 1'-0"4

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat

Threaded stud is secured to aluminum backer with nuts

Tamper-resistant, countersunk fasteners 3

Internal aluminum angle framing stitch-welded to aluminum channel

1/2”thick aluminum spacer5

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in mortar between bricks, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Existing brick masonry wall, fabricator to verify existing conditions prior to final shop drawings

Water-jet/router cut 1” thick aluminum artwork, with short-grain horizontally brushed finish and super-satin clear coat

M3

1'-3"

1/2"

1/2"

2"

1'-3"

10 1/2"

1'-3"

10 1/2" 10 1/2"

10'-3 5/16" (+/-)

2"

1"

1'-11"

1'-6 5/8"

15'-5"

1'-3"

10 1/2"

1"

BID2b – Building ID, Wall-mounted

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.21 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Lockups – BID2c scale: 1/4" = 1'-0"3

West Elevation – Performing Arts Lobby Area H - BID2c scale: 1/4" = 1'-0"1

Typical Side Section Detail – BID2 Alt scale: 3" = 1'-0"2

1/2"

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat

Threaded stud is secured to aluminum backer with nuts2

Tamper-resistant, countersunk fasteners 3

Internal aluminum angle framing stitch-welded to aluminum channel

1/2”thick aluminum spacer5

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in mortar between bricks, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Existing brick masonry wall, fabricator to verify existing conditions prior to final shop drawings

M3

1/2"

1'-3" 1'-3"

1'-3"

2"

EQ EQ

15'-4 3/4" (+/-)

(TBC)

2"

1'-3"

18'-8 3/4"

BID2c – Building ID, Wall-mounted

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.22 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Lockups – BID2d scale: 1/4" = 1'-0"2

Wall Section - Area D scale: 1/4" = 1'-0"3

South Elevation – Gym Area D - BID2d scale: 1/4" = 1'-0"1

LEVEL 1

0' - 0"

LEVEL 2

14' - 0"

GRADE

-2' - 0"

EE

2'-0" TYP.

R1

T.O. MASONRY

20' - 0"

CRICKET,

SEE ROOF PLAN

EW1

Typical Side Section Detail – BID2d scale: 3" = 1'-0"4

10 1/2"

1/2"

1/4"1"

1/2”thick aluminum spacer1

Drill hole and insert threaded stud with appropriate secure anchor, place anchors in mortar between bricks, fabricator to provide details (patch & repair any blemishes from installation to be seamless)

Water-jet/router cut 1” thick aluminum artwork, with short-grain horizontally brushed finish and super-satin clear coat

Existing brick masonry wall, fabricator to verify existing conditions prior to final shop drawings

M3

10 1/2" 10 1/2"

10 1/2" 10 1/2"

1"

1"

1/4"

1/4"

13'-9 1/2" (+/-)

EQ EQ

14'-8"

12'-6 9/16"

2'-6 1/4" 3'-1"

2'-6 1/4"

2'-6 1/4"

BID2d – Building ID, Wall-mounted

Note:

The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.23 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

South Elevation – Gym Area D - BID3 scale: 1/4 " = 1'-0"2

Elevation – BID3 scale: 1/8" = 1'-0"1

2'-8 1/2" 2'-8 1/2"

66'-7 1/2" 3 1/2"

P6 Px

NOTE:

RAIL TO BE PAINTED TO MATCH MULLIONS

BID3 – Building ID, Wall-mounted

Note:

Details for attachment are shown on page

3.24. The provision of additional detailing and

construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.24 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

Side Section Detail – BID3 scale: 3" = 1'-0"2Wall Section - Area D scale: 3/8 " = 1'-0"1

SLOPE FOR PROPER

WATER DRAINAGE

4" 7 1/2"

FASTENER METAL

PANEL VERTICAL

GIRTS

7/8" HAT CHANNEL

0"OC

3 1/2"

2"

2"

Fabricated .080 aluminum channel artwork, horizontally brushed grain with super-satin clear coat

Threaded stud is secured to aluminum angle with nuts2

Neoprene washer3

2” X 2” aluminum angle to attache channel letter with tube rail4

2” x 2” aluminum tube rail to mechanically fastened to girts, fabricator to verify existing conditions prior to final shop drawings

BID3 – Building ID, Wall-mounted

10.03.25 3.25 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential issues or obstructions that will affect the design intent prior to installation.

- Obtaining any necessary engineering seals or permits.

- Verifying compliance with ADA and local sign codes with the appropriate groups for final approval prior to fabrication.

Page Number

Design Intent

As Noted

West Elevation – BID4 scale: 1/4" = 1'-0"2

Lockup BID4a scale: 1/4" = 1'-0"3 Lockup BID4b scale: 1/4" = 1'-0"4

South Elevation – BID4 scale: 1/4" = 1'-0"1

5'-6 5/16"

10'-6"

3'-9 3/16" (+/-)

6'-10 3/4"

5'-3 7/8" (+/-)

3'-6"

3'-6"

7'-0"

EQ EQ

EQ EQ

2'-6"

4'-0"

8'-4 13/16"

8'-10 5/16"

10'-6"

4'-0"

Material yield seams

BID4a, BID4b – Athletics Logo on Gymnasium, Wall-mounted

Note:

Design intent for fabrication and attachment details for sign types BID4a & BID4b are shown on pages 3.26. The provision of additional detailing and construction documentation will need to be included in the awarded fabricator’s scope and will be reviewed by the design team after issued in the form of a shop drawing deliverable. Additionally full-size, vector

10.03.25 3.26 © 2025 Cloud Gehshan Design

Client/Project

Sussex Central High School Exterior Signage and Wayfinding

This drawing represents design intent only. All measurements and installation guidelines are approximate. Sign Fabricator will be responsible for:

- Verifying all dimensions, structures, and existing conditions in the field prior to execution of shop drawings.

- Notifying and coordinating the appropriate groups of any potential…

This is the start of the file's text. The full file is on GovTribe.