Interlude_Arch_and_Bench_Drawing.pdf

PDF 597 KB Posted

Attached to
FURNISH AND INSTALL TRANSIT SHELTERS
Solicitation number
25/26-5
Issued by
Hartford County, Connecticut

About this file

This document is a detailed technical engineering drawing from Brasco International, Inc. for a transit shelter project for the Town of Manchester, specifically an Interlude Transit Shelter design. The technical specification describes two shelters with powder-coated aluminum structures in RAL 9006 white aluminum, featuring 3/8" clear tempered safety glass with stainless steel glass clamps, an arched roof with clear structured polycarbonate glazing, and a solar lighting package. Each shelter includes a solar panel, battery box, motion sensor, and two 3.5' Interlude benches with perforated aluminum bench seats and one seat divider.

The technical drawing provides comprehensive dimensional details, including specific measurements for various shelter components like the battery box, solar panel locations, and bench configurations. The shelters are designed with precise engineering specifications, including a light fixture inside the rafter, a motion sensor to be located in the purlin, and precise reference measurements for structural integrity. The document is marked as confidential and intended solely for Brasco International's customers, with contact information provided at 32400 Industrial Drive in Madison Heights, Michigan.

View the file

Other files

File Type Posted
FURNISH_AND_INSTALL_TRANSIT_SHELTERS.pdf PDF
FURNISH_AND_INSTALL_TRANSIT_SHELTERS.pdf PDF
LIVING_WAGE_CERTIFICATION.pdf PDF
LIVING_WAGE_CERTIFICATION.pdf PDF
Location_Map.pdf PDF
Location_Map.pdf PDF
Interlude_Arch_and_Bench_Drawing.pdf PDF
Finish_Options.pdf PDF
Interlude_Bench_Drawing.pdf PDF
Light_Fixture_Cut_Sheet.pdf PDF
Light_Fixture_Cut_Sheet.pdf PDF
Solar_PLS_Module_Sales_Sheet.pdf PDF
Finish_Options.pdf PDF
Interlude_Arch_Shelter_Cut_Sheet.pdf PDF
Interlude_Bench_Cut_Sheet.pdf PDF
Interlude_Bench_Drawing.pdf PDF
Interlude_Arch_Shelter_Cut_Sheet.pdf PDF
Interlude_Bench_Cut_Sheet.pdf PDF
Manufacturer's_Installation_Instructions.pdf PDF
Solar_PLS_Module_Sales_Sheet.pdf PDF
Manufacturer's_Installation_Instructions.pdf PDF
Town_of_Manchester_Performance_Bond.pdf PDF
Town_of_Manchester_2025_Holiday_Calendar.pdf PDF
Town_of_Manchester_Performance_Bond.pdf PDF
Town_of_Manchester_Contract_(Blank).pdf PDF
Town_of_Manchester_Labor_and_Materials_Payment_Bond.pdf PDF
Town_of_Manchester_2025_Holiday_Calendar.pdf PDF
Town_of_Manchester_Contract_(Blank).pdf PDF
Town_of_Manchester_Labor_and_Materials_Payment_Bond.pdf PDF
Required_Provisions_-_FHWA_funded_projects.pdf PDF
CTDOT_Pre-Award_DBE_Approval_Request_Form.pdf PDF
DWSRF_1445_Labor_Standards_Interview_Form.pdf PDF
Special_Provisions_-_DBE_Requirements_for_Federal_Funded_Projects.pdf PDF
CDBG_Requirements.pdf PDF
Contract_langauge_-_municipal_projects-_CHRO.pdf PDF
DWSRF_1445_Labor_Standards_Interview_Form.pdf PDF
CDBG_Requirements.pdf PDF
Contract_langauge_-_municipal_projects-_CHRO.pdf PDF
Required_Provisions_-_FHWA_funded_projects.pdf PDF
CTDOT_Pre-Award_DBE_Approval_Request_Form.pdf PDF
Special_Provisions_-_DBE_Requirements_for_Federal_Funded_Projects.pdf PDF
Connecticut_Natural_Gas_Requirements.pdf PDF
DWSRF_Contracting_Requirements2.pdf PDF
Prevailing_Wage_Notes_and_Certification_Form_(Attachments_as_of_2023-09-27).pdf PDF
Connecticut_Natural_Gas_Requirements.pdf PDF
DWSRF_Contracting_Requirements2.pdf PDF
Prevailing_Wage_Notes_and_Certification_Form_(Attachments_as_of_2023-09-27).pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION A-A

DETAIL B

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

MODEL: SHEET:JOB #

TOWN OF MANCHESTER CT

INTERLUDE TRANSIT SHELTER

IN-0512-0-0-AR-PT-TG-1-0-S

BMB

7/14/25

A001

CHECKER:

DATE:

REVISION:

A

A A

B

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DRIVE

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

LEAD TIME BEGINS UPON RECEIPT OF SIGNED APPROVAL.

SIGNED:_______________________________ DATE:_____________

LIGHT FIXTURE INSIDE

OF RAFTER

152"

REF.

40"

REF.

40"

REF.

97 11/16"

REF.

60 1/4"

REF.

89 3/8"

REF.

97 9/16"

REF.

102 15/16"

REF.

40.000"

BATTERY BOX

SOLAR PANEL

MOTION SENSOR WILL

BE LOCATED IN PURLIN

QUANTITY ( 2 ) SHELTERS THUS

POWDER COATED ALUMINUM STRUCTURE (RAL 9006 WHITE ALUM.)

REAL WALL ONLY WITH OPEN FRONT AND SIDES

3/8" CLEAR TEMPERED SAFETY GLASS WITH STAINLESS STEEL GLASS CLAMPS

ARCHED ROOF WITH CLEAR STRUCTURED POLYCARBONATE GLAZING

SOLAR LIGHTING PACKAGE WITH SOLAR PANEL, BATTERY AND CONTRLLER IN VENTED ENCLOSURE

PRESSENCE SENSOR SWITCH FOR LED LIGHTING

(2) 3.5' INTERLUDE BENCH WITH PERFORATED ALUMINUM BENCH SEAT AND ONE SEAT DIVIDER

8"

REF.

1 1/2"

REF.

5"

REF.

1 1/2"

REF.

9"

REF.

12"

REF.