Install CCTV Cameras Building 48 Secto KW.pdf

PDF 816 KB Posted

Attached to
CCTV with installation for two Coast Guard units
Solicitation number
70Z028-20-Q-7S1K9100
Issued by

View the file

Other files

File Type Posted
SF_30.pdf PDF
52.212-4.docx DOCX document
Install CCTV Station Islamorada.pdf PDF
52.212-1.docx DOCX document
52.212-5.docx DOCX document
52.212-3.docx DOCX document
Wage Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCOPE OF WORK

FOR

INSTALL ADDITIONAL CAMERAS AND MONITORING STATION IN BUILDING 48

PROJECT #20200420

AT

U.S. COAST GUARD SECTOR KEY WEST

100 TRUMBO RD.

KEY WEST, FL 33040

April 2020

US Coast Guard Sector Key West Project No. 20200420 Install Additional Cameras and Monitoring Station in Building 48

TABLE OF CONTENTS TOC-1 / 1

TABLE OF CONTENTS

DIVISION 1 - GENERAL REQUIREMENTS

011000 SUMMARY OF WORK

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

282300 VIDEO SURVEILLANCE

ENCLOSURES

1. BUILDING 48 – CCTV DRAWING

END OF CONTENTS

SUMMARY 011000 - 1 / 3

SECTION 011000 - SUMMARY

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Project information.

2. Work covered by contract documents.

3. Phased construction.

4. Work by Government.

5. Access to site.

6. Coordination with occupants.

7. Work restrictions.

8. Safety precautions.

9. Site maintenance.

1.2 PROJECT INFORMATION

A. Project Identification: Install Additional Cameras & Monitoring Station in Building 48

– Project #20200420.

1. Project Location: US Coast Guard Sector Key West, 100 Trumbo Road, Key West, Florida 33040.

1.3 SCOPE OF WORK COVERED BY CONTRACT DOCUMENTS

A. The work of project is defined by the contract documents and consists of the following:

1. In general, the project consists of all work, including labor, equipment and materials, necessary to install power over ethernet cameras, door access control, and supporting infrastructure within Building 48. New equipment will be connected to Sector Key West’s existing closed circuit television system and access control system.

SUMMARY 011000 - 2 / 3

WORK SEQUENCE

A. The work shall be conducted by the contractor to provide the least possible interference to the activities of government personnel.

B. Please provide notification to Coast Guard at least one full week prior to starting work.

1.4 WORK BY GOVERNMENT

A. General: Cooperate fully with Government so work may be carried out smoothly, without interfering with or delaying work under this contract or work by Government.

Coordinate the work of this contract with work performed by Government.

1.5 ACCESS TO SITE

A. General: During the construction period the contractor shall have limited use of project site for construction operations as indicated on drawings, as indicated by requirements of this Section, and as specified by the Contracting Officer.

1. Material storage and work areas shall be as designated by the Contracting Officer’s Representative (COR).

B. Pre-Bid Site Visit: Contractors are encouraged but not obligated to visit the site to note existing site conditions. To make arrangements to visit the site, please contact:

1. MLES2 Dale Stauffer

Sector Key West Security Officer Email: Dale.K.Stauffer@uscg.mil Phone: (305) 292-8805

1.6 WORK RESTRICTIONS

A. Work Restrictions, General: Comply with restrictions on construction operations.

1. Comply with limitations on use of public streets and with other requirements of authorities having jurisdiction.

B. On-Site Work Hours: Limit work in the existing building to normal business working hours of 7:00 a.m. to 4:00 p.m., Monday through Friday, unless otherwise indicated.

1. Submit request to the COR at least 72 hours in advance for permission to work outside the normal working hours or on Saturdays, Sundays, or federal holidays.

C. Existing Utility Interruptions: Do not interrupt utilities serving facilities occupied by Government or others unless permitted under the following conditions:

1. Submit request to the COR at least 72 hours in advance of proposed utility interruptions.

SUMMARY 011000 - 3 / 3

2. Obtain COR’s written permission before proceeding with utility interruptions.

D. Take action to prevent the spread of construction dust and debris.

1.7 SITE MAINTENANCE

A. The contractor shall perform daily clean-up of work site, dumpsters and storage area.

All dumpsters shall be covered and watertight should a contractor choose to utilize one.

PART 2 - PRODUCTS (Not Used)

PART 3 - EXECUTION (Not Used)

END OF SECTION 011000

VIDEO SURVEILLANCE 282300 - 1/4

SECTION 282300 - VIDEO SURVEILLANCE

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes a video surveillance system consisting of cameras, digital video recorder, data transmission wiring, fluid mesh transmission points, and other associated equipment.

B. New video surveillance equipment shall be integrated into Coast Guard Sector Key West’s existing system.

C. Contractor shall provide and install all labor equipment, and materials explicitly listed below as well as any necessary ancillary products required to provide a fully functional turn key product.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product indicated. Include dimensions and data on features, performance, electrical characteristics, ratings, and finishes. Please note on any products where the Coast Guard must make a selection (example: color choices). Submit cut sheets on each item for Coast Guard approval prior to installation.

1.3 CLOSEOUT SUBMITTALS

A. At the completion of installation, contractor shall provide manufacturers Operation and maintenance data on all pieces of equipment.

1.4 QUALITY ASSURANCE

A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

B. Comply with NECA 1.

C. Comply with NFPA 70 "National Electrical Code."

1.5 PROJECT CONDITIONS

A. Environmental Conditions: Capable of withstanding the following environmental conditions without mechanical or electrical damage or degradation of operating capability:

1. Interior, Controlled Environment: System components, installed in air-conditioned interior environments shall be rated for continuous operation in ambient temperatures of 36 to 80 deg and 20 to 80 percent relative humidity, noncondensing. Use NEMA 250, Type 1 enclosures.

VIDEO SURVEILLANCE 282300 - 2/4

2. Security Environment: Ensure Camera housing and other infrastructure components for surveillance equipment is installed in a manner, which makes it less susceptible to physical striking and sabotages.

1.6 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of cameras, equipment related to camera operation, and control-station equipment that fail in materials or workmanship within specified warranty period.

1. Warranty Period: 1 year from date of Substantial Completion on all equipment.

PART 2 - PRODUCTS

2.1 Surge Protection: Protect components from voltage surges entering through power, communication, signal, control, or sensing leads. Include surge protection for external wiring of each conductor's entry connection to components.

2.2 STANDARD CAMERAS

A. Manufacturers: Subject to compliance with requirements, provide products by the following manufacturer or an approved equal with the same minimum salient characteristics.

B. Exterior Grade Camera Model - Basis of Design Information:

1. Manufacturer: 3xLogic

2. Model: VISIX V-Series 4MP Outdoor Mini Dome IP Camera

3. Model Number: VX-4V28-MD-IAW

4. Quantity: 6 cameras.

5. Salient Characteristics:

a. Exterior Grade

b. Resolution (Megapixels): Minimum 4

6. Notes: Provide all necessary hardware including mounting brackets, junction boxes, and conduit as necessary to install cameras.

2.3 COLOR MONITORS

A. Manufacturers: Subject to compliance with requirements, provide products by the following manufacturers or an approved equal with the same minimum salient characteristics.

B. Color LED Monitor Type 1 – Basis-of-Design Information:

1. Manufacturer: Dell

2. Model: C7016H - 70” Screen LED-Lit Monitor

3. Quantity: 2

4. Salient Characteristics

a. Resolution: 1920 x 1080p

b. Screen Size: 70”

VIDEO SURVEILLANCE 282300 - 3/4

5. Note: Provide mounting bracket and necessary hardware for installation.

a. Mount Manufacturer: Peerless-AV

b. Mount Model: PLCMUNLCP – SmartMount Universal Ceiling mount for 32” to

90” Displays.

c. Mount Quantity: 2

C. Color LED Monitor Type 2 – Basis-of-Design Information:

1. Manufacturer: Northern

2. Model: LED22R – 21.5” Widescreen LED Security Monitor

3. Quantity: 2

4. Salient Characteristics:

a. Resolution: 1920 x 1080p

b. Screen Size: 21.5”

2.4 DESKTOP COMPUTER

A. Manufacturers: Subject to compliance with requirements, provide products by the following manufacturers or an approved equal with the same minimum salient characteristics.

B. Desktop Security Computers

1. Manufacturer: Dell

2. Model: 5FHC3 – Dell OptiPlex 3060

3. Hard Drive: 500 gb

4. Processor: 3 GHz Core i5-8500

5. Memory: 4gb Random Access Memory

6. Quantity: 2

2.5 GENERAL

A. The contractor shall provide and install all of the networking equipment required to support new cameras at the specified locations and new monitoring stations. Monitoring station in the Command Center shall be capable of viewing all existing and new camera feeds by cycling through to desired camera view. Contractor is responsible for ensuring all existing server, software, and recording equipment can properly support additional cameras. Contractor shall provide and install additional software licenses, cabling, conduit, mounting brackets, security panels, server upgrades, etc. necessary to achieve a fully functional system.

PART 3 - EXECUTION

3.1 TIE-IN TO EXISTING SYSTEM

A. All video surveillance components shall tie into existing Stanley Security Systems control panels, software, and networking devices. Contractor shall provide and install any necessary additional hardware to interface new equipment with existing system.

1. Integrate with Existing Software:

a. 3xLogic Vigil Client

VIDEO SURVEILLANCE 282300 - 4/4

3.2 WIRING

A. Wiring Method: Install cables in security type tamper proof raceways or conduit unless otherwise indicated.

1. Except raceways are not required in accessible indoor ceiling spaces and attics.

2. Except raceways are not required in hollow gypsum board partitions.

3. Conceal raceways and wiring except in unfinished spaces.

3.3 VIDEO SURVEILLANCE SYSTEM INSTALLATION

A. Set pan-and-tilt unit stops to suit final camera position and to obtain the field of view required for camera. Connect all controls and alarms, and adjust.

3.4 FIELD QUALITY CONTROL

A. Tests and Inspections:

1. Inspection: Verify that units and controls are properly installed, connected, and labeled, and that interconnecting wires and terminals are identified.

2. Pretesting: Align and adjust system and pretest components, wiring, and functions to verify that they comply with specified requirements. Conduct tests at varying lighting levels, including day and night scenes as applicable. Demonstrate successful operation to the Coast Guard.

B. Video surveillance system will be considered defective if it does not pass tests and inspections.

3.5 TRAINING

A. Provide training to Coast Guard's personnel to adjust, operate, and maintain video-surveillance equipment.

END OF SECTION 282300

LPMcCue Rectangle

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Rectangle

LPMcCue Rectangle

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Rectangle

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Rectangle

LPMcCue Rectangle

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Line

LPMcCue Typewritten Text

EXISTING SECURITY OFFICE AND MONITORING POINT

LPMcCue Typewritten Text

LPMcCue Typewritten Text

LPMcCue Typewritten Text

LPMcCue Typewritten Text

LPMcCue Typewritten Text

LPMcCue Typewritten Text

LPMcCue Typewritten Text

INSTALL 6 NEW CAMERAS

AS SHOWN.

LPMcCue Line

LPMcCue Typewritten Text

INSTALL NEW 70" MONITORS AND

NEW SECURITY MONITORING

COMPUTER STATIONS

File details come from the government source that posted it. Updated .