Index Roof Plan.pdf

PDF 2 MB Posted

Attached to
INDEX ROOF FLUID APPLIED ROOF
Solicitation number
27-350SOS-PHYSE-B-54721
Issued by
Sangamon County, Illinois

About this file

This is an Index Roof Plan document for the Illinois Secretary of State's fluid applied roof system project at the Index Building located at 111 E. Monroe Street, Springfield, Illinois 62701. The project involves the installation of a new fluid applied roof system on the Index Building. The document serves as a technical plan and specification reference for bidders responding to the Invitation for Bid (IFB) for this roofing project. Specific details regarding quantities, project timeline, site visit requirements, bidders' meetings, response deadlines, and contract award dates are referenced in the attached IFB and accompanying drawings, which provide the complete procurement parameters for this state construction project.

The Index Roof Plan document functions as a supporting exhibit to the primary IFB documentation and is essential for bidders to understand the physical scope and technical specifications of the roofing work. Pricing, set-asides, incumbent contractor information, funding sources, and other financial terms are detailed in the main IFB document rather than in this plan drawing. Bidders must consult the complete IFB package, including all drawings and specifications, to develop accurate cost proposals and ensure compliance with all procurement requirements established by the Illinois Secretary of State.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

111' -10

27'-412" 12'-0"

6' -9

27'-412"

'-9

24'-4"

EXISTING METAL WALL

PANEL

METAL CLOSURE TRIM -

PAINT

HEAD FLASHING

BACKER ROD & SEALANT

DOOR AND FRAME - SEE

SCHEDULE

EXIST. METAL WALL PANEL

METAL CLOSURE TRIM

DOOR AND FRAME - SEE

SCHEDULE

BACKER ROD & SEALANT

INSUL. METAL DOOR & FRAME

ALUM. THRESHOLD

2 PIECE COUNTERFLASHING UNDER

THRESHOLD

FLUID APPLIED ROOFING SYSTEM

OVER EXISTING EPDM ROOFING

SCALE: 112" = 1'-0"

DOOR DETAILS3

6"X6"X3/8"

STEEL LINTEL -

8" MIN. BEARING

(EACH SIDE)

SHOP PRIME/

FIELD PAINT

2"

MIN.

2"

MIN.

4"

MIN.

4" MI

N.

METHOD A METHOD B

4" MIN.

COAT PRIMER

(MASTIC) (FABRIC)

COAT PRIMER

NEW APPLIED

COAT MASTIC

REINFORCEMENT FABRIC

EMBEDDED IN COATING

EXISTING FLASHING IS

REFURBISHED WITH TWO LAYERS

OF COATINGS WITH EMBEDDED

REINFORCING FABRIC

COAT MASTIC

3'-0"±

4' -0

1'- 87 16"

A-1

BRH

© Evan Lloyd Associates, Inc.

Date:

Drawn By:

Revised:

Revised:

Project No.

SHEET

OF SHEET.

Date Signed:

Expiration Date:

S ou th Si xth S tre et

Sp rin gfi eld

, Il lin ois

Ph on e

7.7

.70

RO

OF

R

EP

LA

CE

ME

NT

IL

LI

NO

IS

S

EC

RE

TA

RY

O

F

ST

AT

E

PO

LI

CE

B

UI

LD

IN

G

1 E

AS

T

MO

NO

RE

S

TR

EE

T

0 E

AS

T

AD

AM

S

ST

RE

ET

SP

RI

NG

FI

EL

D, IL

LIN

OI

S

OCT. 10, 2024

24050

NOV. 30, 2024

NORTH SCALE: 18" = 1'-0"

ROOF PLAN

GENERAL NOTES:

A. COORDINATE DEMOLITION & PHASING WITH

USING AGENCY. EVERY EFFORT SHALL BE MADE

TO MINIMIZE DISRUPTION OF USING AGENCY'S

OPERATIONS & PROVIDE BUILDING USER'S

SAFETY. EXCESSIVE NOISE OR VIBRATION MUST

BE PRE-APPROVED & COORDINATED WITH

USING AGENCY.

B. COORDINATE DISRUPTION OF UTILITY SERVICES

WITH USING AGENCY & AS SPECIFIED.

C. MAINTAIN A SECURE & WEATHER-TIGHT ENCLOSURE.

D. CONTRACTOR TO FIELD VERIFY EXISTING

CONDITIONING. DIMENSIONS & ELEVATIONS SHOWN

ON PLANS PRIOR TO THE START OF WORK. NOTIFY

ARCHITECT OF ANY DISCREPANCIES FOUND.

E. PROVIDE PROTECTION FOR EXISTING BUILDING

MATERIALS & EQUIPMENT FROM DAMAGE DUE TO

DEMOLITION OR CONSTRUCTION PERFORMED

UNDER THIS CONTRACT.

F. REPAIR OR REPLACE ITEMS DAMAGED AS A

RESULT OF DEMOLITION OR CONSTRUCTION TO

MATCH EXISTING FINISH AND/OR CONDITION.

G. EXISTING MATERIALS SHALL NOT BE REUSED

UNLESS OTHERWISE NOTED. OR AS AUTHORIZED BY

THE USING AGENCY.

H. VERIFY & MAINTAIN LOCATION OF EXISTING POWER,

COMMUNICATION & DATA CABLES TO PREVENT

INTERRUPTION OF SERVICES.

I. REPLACE OR EXTEND EXISTING DOWNSPOUT

ADJACENT TO AREA OF WORK. REPOSITION STRAP

ATTACHING EXISTING DOWNSPOUT ELBOW TO

SPLASH PAN AS REQUIRED. REPORT

INCONSISTENCIES TO ARCHITECT.

J. THE USING AGENCY SHALL RESERVE THE RIGHT TO

SALVAGE ANY MATERIALS.

KEY VALUE

EXISTING ± 3-4" ROOF SYSTEM - EPDM MEMBRANE

1/2" FIBER BOARD. POLYISCO. INSUL. BOARD.

DECK VARIES (CONC. METAL & WOOD). INSTALL

FLUID APPLIED ROOFING (SEE SPEC. SECTION

07 5800).

DOWNSPOUT, BELOW. STRAP AND SPLASH PAN.

CONCRETE COPING

CURB FLASHING AT UNDERSIDE OF CURB

CAP OR HVAC UNIT.

KEYNOTE LEGEND

KEY TEXT

CLOSED-CIRCUIT COOLING TOWER

ABANDONED ERU UNIT

COOLING TOWER & PIPING

ACCU.

INTAKE VENTILATOR

GRAVITY VENT

ELECTRICAL WIRING. PIPING.

AND CONNECTIONS FOR PARAPET FLOOD

LIGHTING AND CAMERA SURVEILLANCE.

WOOD STAIR

ACTIVE ANTENNA

GRAVITY VENT CURB

AT EXISTING ROOF DRAINS: REMOVE STRAINER

AND DRAIN COMPONENTS, DRAIN BODY TO

REMAIN. INSTALL DRAIN PRIOR TO INSTALLATION

OF FLUID APPLIED ROOFING.

AT EXISTING GUY WIRES, INSTALL 2" MIN. DIA. WHITE

PLASTIC SLEEVE EXTENDED 7" ABOVE ROOF

SURFACE TO MEET SECTION 376.4 OF

INTERNATIONAL PIPE CODE FOR VISIBILITY.

SCALE: 112" = 1'-0"

PIPE/TUBING FLASHING DETAIL5

SCALE: 12" = 1'-0"

PARTIAL ELEVATION4

FRAME DOOR

DOOR & FRAME SCHEDULE

TY

PE

TY

PE

MAT'L FIN. W H T

PT.H.M. 3'-0" 4'-0" 1 3/4" PT.H.M.

MAT'L FIN. REMARKS

SEE PARTIAL ELEVATION

DETAIL

3/A-1

H.

W.

SE

TSIZE

DO

OR

N O.

THRESHOLD SET IN CONT.

BEAD OF SEALANT

REMOVE DOOR & FRAME.

INSTALL INSULATED

METAL DOOR & FRAME -

PT.

EXISTING METAL PANEL

A

F 0 2

G

P D

C

C

C

P

P

M

9D

D15

13 C

N

H

N

G

D

PRIOR TO INSTALLATION OF FLUID APPLIED

ROOFING, PROVIDE NEW CRICKET AT THIS LOCATION

TO PROVIDE POSITIVE DRAINAGE AND DIRECT WATER

TO NEAREST ADJACENT DRAIN. MODIFY & EXTEND

PENETRATIONS & CURBS EFFECTED BY CRICKET AS REQ'D

TO MEET ROOFING WARRANTY

B

E

G

G

L

F

F

C

K K

C

REMOVE PAVERS

(TYP.)

C

A

A-1

AT SHADED AREAS PREPARE EXISTING

EPDM ROOF SYSTEM AND INSTALL FLUID

APPLIED RO0FING SYSTEMS PER

MANUFACTURER'S REQUIREMENTS. (SEE

SPECIFICATION FOR ADDITIONAL

SYSTEM INFORMATION.)

REMOVE PAVERS

D TYP.

TYP.

A

DS

DS

EXISTING

MASONRY WALL

EXISTING

MASONRY WALL

EXISTING

MASONRY WALL

EXISTING

CONC. DECK

REMOVE PAVERS

(TYP.)

REMOVE PAVERS

(TYP.)

NOTE:

ALL HARDWARE SHALL BE HEAVY-DUTY

COMMERCIAL GRADE, W/ US26D FINISH

SET NO. 1

S.S. BALL-BEARING BUTT HINGES W/NRP

MORTISE LEVERSET (USING AGENCY TO PROVIDE S.O.T. CORE)

ALUM. THRESHOLD

CA

A

A

F

EXISTING CAPPED

VENTS & ACCU.

CURBS (TYP.)

EXISTING GOOSE

NECK EXHAUST VENT

EXISTING PIPE

PENETRATION

EXISTING PIPE

PENETRATION

EXISTING PIPE

PENETRATION

UP

A A

DS

DS

(2) EXISTING

ABANDONED CABLE

ANCHORS

SLO

PE

SLOPE

SLO

PE

SLOPE

SLOPE

SLO

PE

SLOPE

B

BB

SL

OP

E

SL

OP

E

SLOPE

SLOPE

SLOPE

SLOPE

SLOPE SLOPE

SL

OP

E

SLOPE SLOPE

EXISTING

ROOF SCUPPER

SL

OP

E

SL

OP

E

SLOPE

SLOPE

SLOPE

SLOPE

EXISTING ROOF

SCUPPER

EXISTING ROOF

SCUPPER

INSTALL TAPERED

INSULATION

ALONG ENTIRE

PARAPET (THIS SIDE)

SLOPE

WR

NEW DOOR

T

SILL

JAMB

HEAD

K

I

J

PENETRATION SCHEDULE

PENETRATION

MARK TYPE SIZE HT.

PIPE 3" DIA. 8"

MISC. 8" DIA. 2"

MISC. 8" DIA. 2" ANCHOR

PIPE 3" DIA. 12"

RAIL

RAIL

48"X4"10"-12"(2) TYPICAL

38"X4"10"-12"(2) TYPICAL

CURB30" DIA.18" CAPPED PENETRATION

MISC.

MISC.

48"X48" 8"X8"

10"

7" (3) ANCHOR

EQUIP. PLATFORM

MISC.18"X17-8" 10" EQUIP. PLATFORM

CURB35"X40"11"

MISC. 4"X4" - (3) HOLLOW TUBE STEEL

CURB24"X24" 8"

CURB20"X20" 12"

CURB24"X24" 8"

RAIL 4"X50" 8"-11" (11) TYPICAL

RADIO TOWER ANCHOR

CAPPED PENETRATION

EXHAUST PIPE

EXHAUST PIPE

EXHAUST VENT

EXHAUST VENT

ACCU

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

K

K

NEW PROTECTIVE WALK

MEMBRANE. ADHERE TO ROOF.

AutoCAD SHX Text

HARDWARE SCHEDULE

Sheets and Views
Layout

File details come from the government source that posted it. Updated .