IFB 306852501_Addendum 3.pdf

PDF 12 MB Posted

Attached to
Owens Hall Chick-fil-A Renovations
Solicitation number
85722
Issued by
Middlesex County, Virginia

About this file

This is Addendum 3 to IFB #306852501 issued by Virginia Polytechnic Institute and State University (Virginia Tech) for renovations to the Chick-fil-A location in Owens Hall. The project involves complete demolition of the existing Chick-fil-A venue and construction of a new restaurant with storage area, all within the existing building. Key changes in the addendum include the addition of an additive bid item for additional tile area at the front service counter, requirement for professional cleaning at project end, and extension of the bid due date from February 14, 2025 to February 21, 2025 at 2:00 PM, with bid opening via Zoom on February 24, 2025. The project requires substantial completion by September 1, 2025, with final completion within 30 days thereafter.

The contractor must achieve a 50% small business participation goal for the project. The work requires temporary containment walls with Level 3 finish on the public side during construction since work will occur during fall classes. The scope includes installation of new equipment, fixtures, finishes, mechanical systems, and utilities. The contractor is responsible for installing owner-furnished FF&E/millwork. Detailed equipment schedules, mechanical drawings, and electrical specifications are provided to guide installation requirements for kitchen equipment, utilities, and building systems.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VIRGINIA POLYTECHNIC INSTITUTE AND STATE UNIVERSITY

PROCUREMENT DEPARTMENT

ADDENDUM NO. 3

DATE: February 11, 2025 TO: All Offerors FROM: Ted Alt, Buyer Specialist TOTAL PAGE(S): 2 pages (not including attachments) SOLICITATION TITLE: Owens Hall Chick-fil-A Renovations

SOLICITATION NUMBER: 306852501

I. CLARIFICATIONS AND ADDITIONAL INFORMATION

1. An Additive has been added to the bid form. Please use the updated bid form, attached as Exhibit A, when submitting your bid.

2. See sheet D1 for schematic location of Temporary Wall required during construction.

3. The Contractor shall hire professional cleaning company and end of project for cleaning all areas affected by construction activities.

4. Equipment Schedule can be found on Sheet A3.1 of the Drawings and additional information found on the engineering sheets.

5. The Owner shall furnish FF&E/Millwork. Contractor shall install all FF&E/Millwork.

6. Due date is being moved:

Previous Date: February 14, 2025, at 2:00 PM New Date: February 21, 2025, at 2:00 PM

The bid opening will take place on February 24, 2025, at 2:00 PM via Zoom. Details can be found in the Notice of Advertisement.

Clarifications on Drawings:

1. The revised drawings attached as Exhibit B dated February 3, 2025, replace the previously issued drawings in their entirety.

II. REQUESTS FOR INFORMATION

1. Are there any bidder qualifications we should be aware of?

Virginia Tech Response: See bid documents.

2. Who is responsible for providing sink?

Virginia Tech Response: See Equipment Schedule on Sheet A3.1 and additional information found on the plumbing sheets.

3. Can you provide information on the equipment schedule as to what is owner provided, contractor provided, or franchise provided, and who is to install these items?

Virginia Tech Response: See updated Equipment Schedule on Sheet A3.1

4. Sections 1-12 on page A6 have tags stating that they come from page A1. I have found no designation on page A1 for these sections. Can you provide information on where they came from?

Virginia Tech Response: Tags have been added on Sheet A1

5. Sink S-1 has no tag to link it to the equipment schedule. Can you provide information on the sink and whether it is provided by the owner or not?

Virginia Tech Response: Sink S-1 is specified on Sheet P2. Sink S-1 and associated faucet for sink S-1 are to be provided by the contractor. See specifications on sheet P2 and Equipment Schedule on Sheet A3.1 for information on other required sinks and faucets.

6. There are several pieces of equipment that are not defined in the schedules on

A3.1. for example 702,703S,703L,703M,421,300a, & 300X are all not defined in the equipment schedules. Can we have the information on the remaining equipment tags?

Virginia Tech Response: See updated Equipment Schedule on Sheet A3.1

7. On page P2, there is a note under kitchen equipment that says, “Coordinate with owner kitchen equipment and make water, waste, and vent pipe connections.

Coordinate locations, dimensions, connection sizes and details with equipment installation instructions. See owner equipment drawings for equipment identification and plumbing schedule indicating equipment connections. Plumber shall provide devices such as stops, risers, thermostatic mixing valves, traps, pressure reducing valves, fittings, and other plumbing accessories for a complete installation of kitchen equipment.” When will we have access to these?

Virginia Tech Response: Kitchen equipment requiring plumbing connections is indicated on the plumbing drawings.

8. What is the power source for fryers (electric, natural gas, etc.)?

Virginia Tech Response: See electrical drawings

Exhibit A Updated Bid Form

Standard Bid Form Format

BID FORM

(DGS Rev. 07/22) (VT Rev. 2/24)

DATE:

PROJECT: Owens Hall Chick-fil-A Renovations Blacksburg, VA

IFB #: 306852501

To: Virginia Polytechnic Institute and State University North End Center, Suite 2100

300 Turner Street, NW Blacksburg, VA 24061

In compliance with and subject to your Invitation for Bids and the documents therein specified, all of which are incorporated herein by reference, the undersigned bidder proposes to furnish all labor, equipment, and materials and perform all work necessary for construction of this project, in accordance with the Plans and Specifications dated November 20, 2024, and the Addenda noted below, as prepared by The Architects Alliance Inc. for the consideration of the following amount:

BASE BID (including the following parts but excluding work in Additive Bid Items):

TOTAL BASE BID AMOUNT IS:

_______________________________________________________ DOLLARS ($ )

ADDITIVE BID ITEM 1: Lump sum price for all work to add additional tile area at front service counter, complete, in accordance with the drawings and specifications is

____________________________________________ Dollars ($ )

Contract award will be based on the TOTAL BASE BID AMOUNT shown above (including any properly submitted bid modifications) plus as many Additive Bid Items taken in sequence as the Owner in its discretion decides to award.

The bidder has relied upon the following public historical climatological records:

NOAA for Blacksburg, VA

Code of Virginia, § 2.2-4376.2 shall be applicable to the Work of the Contract.

The undersigned understands that time is of the essence and agrees that the date for Substantial Completion of the entire project shall be on or before September 1, 2025, and Final Completion shall be achieved within 30 consecutive calendar days after the date of Substantial Completion as determined by the A/E.

Acknowledgment is made of receipt of the following Addenda:

If notice of acceptance of this bid is given to the undersigned within 30 days after the date of opening of bids, or any time thereafter before this bid is withdrawn, the undersigned will execute and deliver a contract in the prescribed form (Commonwealth of Virginia Contract Between Owner and Contractor, Form CO-9) within 10 days after the contract has been presented to him for signature. The required payment and performance bonds, on the forms prescribed, shall be delivered to the Owner along with the signed Contract.

Immigration Reform and Control Act of 1986: The undersigned certifies that it does not and shall not during the performance of the Contract for this project violate the provisions of the Federal Immigration Reform and Control Act of 1986, which prohibits employment of illegal aliens, or knowingly employ an unauthorized alien as defined in the Federal Immigration Reform and Control Act of 1986.

DISQUALIFICATION OF CONTRACTORS: By signing this bid or proposal, the undersigned certifies that this Bidder or any officer, director, partner or owner is not currently barred from bidding on contracts by any Agency of the Commonwealth of Virginia, or any public body or agency of another state, or any agency of the federal government, nor is this Bidder a subsidiary or affiliate of any firm/corporation that is currently barred from bidding on contracts by any of the same. We have attached an explanation of any previous disbarment(s) and copies of notice(s) of reinstatement(s).

DISQUALIFICATION FOR WAGE THEFT: By signing this bid or proposal, the undersigned certifies that this Bidder or their proposed subcontractor(s), or any officer, director, partner or owner thereof is not currently in litigation, under investigation, or criminal indictment for wage theft on contracts by any Agency of the Commonwealth of Virginia, or any public body or agency of another state, or any agency of the federal government.

The apparent low bidder shall submit, within two (2) business days of the bid opening, a complete subcontracting plan listing all tiered subcontractors on the DGS-30-360 form, which can be downloaded from: https://dgs.virginia.gov/search/documents-and-forms/. In addition, Bidder shall identify all subcontractors that are Small, Women Owned and Minority Owned firms.

Agency Small Business Participation Goal: % 50

Contractor’s Proposed Small Business Participation: % ___________ (required)

Either the undersigned or one of the following individuals, if any, is authorized to modify this bid prior to the deadline for receipt of bids by writing the modification and signing his name on the face of the bid, on the envelope in which it is enclosed, on a separate document, or on a document which is telefaxed to the Owner:

https://dgs.virginia.gov/search/documents-and-forms/

I certify that the firm name given below is the true and complete name of the bidder and that the bidder is legally qualified and licensed by the Virginia Department of Professional and Occupational Regulation, Board for Contractors, to perform all Work included in the scope of the Contract.

Virginia License No.: ______________ Bidder: ______________________________

(Name of Firm)

Contractor Class: ________________ By:___________________________________ (Signature)

By:____________________________________ (Print Name)

Email: _________________________________ (Print Email Address)

Specialty: _______________________ Valid until: ______________________

FEIN/SSN: _____________________ Title: _______________________________

If General Partnership (List Partners' Names)

Business Address:

Telephone # ________________________

FAX # _______________________________

If Corporation, affix Corporate Seal & list State of Incorporation

State: _____________________________

(Affix Seal)

Virginia State Corporation Commission ID No.: _______________; or

If Contractor is a foreign business entity not required to be authorized to transact business in the Commonwealth under Titles 13.1 or 50 of the Code of Virginia, or as otherwise required by law, please provide an explanation as to why such entity is not required to be so authorized: ____________________

Exhibit B Updated Drawings dated February 3, 2025

LOCATION MAP:

Virginia Polytechnic Institute & State University Commonwealth of Virginia 150 Kent Street, Blacksburg, VA 24061

O W

E N

S H

A

LL

C H

IC

K

-F

IL

-A R

E N

O V

A T

IO

N

S

SOUTHGATE DRIVE

TECH

VIRGINIA

ROAD

M

AIN STREET

AIR

PO

R T

460 BYPASS

U .S. R

O U

TE

TECH

CORPORATE

PRICESFORK

R O

AD

DRIL

L

FIE

LD

AIRPORT

VIRGINIA

RESEARCH

CENTER

W

ASHIN

GTON S

TREET

W

EST CAM

PU

S

D R

IV

E

N O

R T

H D

RAPER RD

ROANOKE ST.

SEAL:

CODE INFORMATION: INDEX OF DRAWINGS:

Inc.

Alliance Architects The

ARCHITECT:

VT Work Order #: 25-688542

APPLICABLE CODES:

USE GROUP:

CONSTRUCTION CLASSIFICATION:

VUSBC OCCUPANCY:

DESIGN LIVE LOADS:

TOTAL BUILDING FLOOR AREA:

TOTAL RENOVATION AREA:

FIRE SUPPRESSION SYSTEM:

FIRE ALARM SYSTEM:

T1 LOCATION MAP, CODE INFORMATION, HAZARDOUS MATERIALS NOTES

LS1 KEY PLANS, CODE ANALYSIS NOTES, SCHEDULES

D1 FLOOR PLAN - EXISTING CONDITIONS & DEMOLITION, DEMOLITION NOTES

D2 REFLECTED CEILING PLAN - EXISTING CONDITIONS & DEMOLITION

A1 PARTIAL FIRST FLOOR DIMENSIONAL PLAN, NOTES

A1.1 WALL TYPE DETAILS, DOOR SCHEDULE & DETAILS, COUNTERTOP PLAN

A2 PARTIAL FIRST FLOOR FINISHES PLAN, NOTES

A2.1 PARTIAL FIRST FLOOR REFLECTED CEILING PLAN

A2.2 FINISH SCHEDULES

A3 PARTIAL FIRST FLOOR KITCHEN EQUIPMENT PLAN

A3.1 KITCHEN EQUIPMENT SCHEDULES

A4 INTERIOR ELEVATIONS

A5 INTERIOR ELEVATIONS

A6 SECTIONS & DETAILS

A7 DETAILS

A8 EQUIPMENT DETAILS

A9 OUTLINE SPECIFICATIONS

A10 OUTLINE SPECIFICATIONS

S1 STRUCTURAL DETAILS, NOTES

MD1 PARTIAL FIRST FLOOR PLAN - MECHANICAL DEMOLITION, NOTES

M1 PARTIAL FIRST FLOOR PLAN - MECHANICAL

M2 MECHANICAL OUTLINE SPECIFICATIONS, LEGENDS

PD1 PARTIAL FIRST FLOOR PLAN - PLUMBING DEMOLITION, DEMOLITION NOTES

P1 PARTIAL FIRST FLOOR PLAN - PLUMBING, NOTES

P2 PLUMBING OUTLINE SPECIFICATIONS, LEGENDS

ED1 ELECTRICAL FLOOR PLAN - EXIST. CONDITIONS/DEMOLITION, NOTES

ED2 ELECTRICAL REFLECTED CEILING PLAN - EXIST. CONDITIONS/DEMOLITION

ED3 EXISTING PANEL SCHEDULES

E1 ELECTRICAL NOTES, ELECTRICAL OUTLINE SPECIFICATIONS

E2.1 PARTIAL FIRST FLOOR POWER, DATA & EQUIPMENT PLAN

E2.2 EQUIPMENT SCHEDULE - ELECTRICAL

E3 PARTIAL FIRST FLOOR REFLECTED CEILING PLAN - ELECTRICAL

E4 MODIFIED PANEL SCHEDULES

LEAD-CONTAINING PAINT NOTES:

ASBESTOS-CONTAINING MATERIALS NOTES:

ASBESTOS-CONTAINING MATERIALS OR PAINTS CONTAINING LEAD SHALL NOT BE USED IN ANY FORM ON STATE PROPERTY (VA TECH).

ALL INFORMATION RELATED TO ASBESTOS-CONTAINING AND LEAD-CONTAINING MATERIALS IS PROVIDED BY VIRGINIA TECH SAFETY COMPLIANCE OFFICER, WHO SHALL BE CONTACTED FOR ALL DETAILS AND PROCEDURES RELATED TO SUCH MATERIALS, AT 540.231.9397.

OWENS HALL CHICK-FIL-A RENOVATIONS

Gibson Engineering, LLC

ELECTRICAL ENGINEER:

Mann & Associates Inc.

MECHANICAL ENGINEER:

VT IFB #: 306852501

AN ASBESTOS INSPECTION WAS PERFORMED AND NO ACM WAS FOUND. THE ASBESTOS INSPECTION REPORT IS INCLUDED IN THE INVITATION FOR BIDS. IF A SUSPECT ASBESTOS-CONTAINING MATERIAL IS ENCOUNTERED IN THE COURSE OF THIS WORK, WORK SHALL STOP IMMEDIATELY AND THE SAFETY COMPLIANCE OFFICER SHALL BE CONTACTED AT 540.231.9397.

A LEAD-CONTAINING PAINT INSPECTION WAS PERFORMED AND NO LEAD CONTAINING PAINT WAS FOUND. THE LEAD-CONTAINING PAINT INSPECTION REPORT IS INCLUDED IN THE INVITATION FOR BIDS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR'S USE AND MAY NOT BE ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY & HEALTH REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. IF A SUSPECT LEAD-CONTAINING MATERIAL IS ENCOUNTERED IN THE COURSE OF THIS WORK, WORK SHALL STOP IMMEDIATELY AND THE SAFETY COMPLIANCE OFFICER SHALL BE CONTACTED AT

540.231.9397. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.

2021 Virginia Uniform Statewide Building Code (VUSBC), Part II, adopted January 18, 2024, also known as the 2021 Virginia Existing Building Code (VEBC - Level 2 Alteration), and incorporating the 2021 International Building Codes with Virginia amendments

Americans with Disabilities Act 2010 ADA Standards for Accessible Design (ADA 2010), published September 15, 2010, and adopted March 1, 2011

Virginia Accessibility Code 2017 Virginia Plumbing Code 2021 Virginia Mechanical Code 2021 Virginia Electrical Code 2020 National Fire Alarm and Signaling Code - NFPA 72, 2019 Edition Standard for Wet Chemical Extinguishing Systems - NFPA 17A, 2021 Edition VT Construction and Professional Services Manual (CPSM), 2020 Edition, adopted January 24, 2020 VT Design and Construction Standards Manual, effective July 1, 2023

B (Business), A2 (Assembly) - Non Separated Mixed Use - Unchanged IIB - Unchanged Unchanged

Not Applicable - No Structural Modifications required for this Project

97,688± GSF

1,200± GSF

Automatic Fire Extinguishing System (at Kitchen Exhaust Hoods) Automatic Fire Alarm System

DATE:

TAA PROJECT NO.: 96554

February, 3, 2025

VT Building #: 0195

UBO NOTATION:

PROJECT

SITE

SHANE LARKIN

Lic. No. 016372

THE CONTRACTOR SHALL COMPLY WITH "VIRGINIA TECH'S SAFETY REQUIREMENTS FOR CONTRACTORS AND SUBCONTRACTORS PROGRAM", WHICH IS INCORPORATED IN THESE DOCUMENTS BY REFERENCE. COPIES OF THIS PROGRAM ARE AVAILABLE FROM THE

OWNER, OR MAY BE DOWNLOADED AT <WWW.EHS.VT.EDU>

Day & Kinder Consulting Engineers PLLC

STRUCTURAL ENGINEER:

02/03/2025

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

K E

Y P

LA

N

S , C

O D

E A

N A

LY

S

IS

N

O T

E S

, S C

H E

D U

LE

S

O W

E N

S H

A L

L C

H

IC

K −F

IL

−A

R E

N O

V A

T

IO

N S

V

IR

G

IN

IA

P

O

LY

T E

C H

N

IC

IN

S

T

IT

U T

E

S T

A T

E U

N

IV

E R

S

IT

Y

SLL

SLL

SLL

96554

2/03/25

LS1

1/16" = 1'-0"

0 2 4 6 10 20 40

KEY PLAN NOTES:

1. KEY PLAN DRAWINGS ARE SCHEMATIC, AND

ARE NOT DRAWN ACCURATELY TO SCALE. SEE

EXISTING CONDITIONS/DEMOLITION FLOOR

PLANS ON SHEETS D1 & D2 FOR MORE DETAILS

OF EXISTING CONDITIONS.

UBO NOTATION:

100D

100J

B25

B1

B5B6

B8

107B

107A

107C

B10

B12

B11

B13

B14

B15

114A

114B

B16

B17

100A 100B

100H

100F

100E

B21

B26

100C

100K

B22

100G

B24

100L

B29

101E 101D 101B

101C

104 102 102

B27B31

L O

A D

IN

G

D O

C K

B23

B20

B19

B18

113A

101F

B32

B20A

B5A

103C 103B

103A

B4

B9

115A

108A

101A

117A

101G

113B

B33

DN

DNUP

DN

UP

UP UP

UP

UP

UP

UP

102104

UP

103B1

103B3

103B2

UP

SCALE: 1/16"=1'-0"

FIRST FLOOR KEY PLANPLAN

NORTH

CODE ANALYSIS NOTES:

1. THE EXISTING BUILDING USE GROUP OF B AND A2 IS NOT CHANGED BY THIS PROJECT.

2. THE EXISTING BUILDING CONSTRUCTION CLASSIFICATION (ASSUMED IIB) IS NOT CHANGED BY

THIS PROJECT.

3. THE EXISTING BUILDING HEIGHT AND AREA ARE NOT CHANGED BY THIS PROJECT.

4. THE EXISTING BUILDING IS NOT SPRINKLERED. THE EXISTING BUILDING HAS AN AUTOMATIC

FIRE ALARM SYSTEM, WHICH WILL BE RE-CONFIGURED WITHIN THE RENOVATION AREAS AS

REQD. FOR COMPLIANCE WITH THE 2021 VCC.

5. THE CORRIDOR WALLS ARE REQD. TO HAVE A 1 HOUR FIRE RATING UNDER CURRENT CODE

(VCC TABLE 1020.1). THE RENOVATION AREA DOES NOT INCLUDE ANY CORRIDORS AND IS NOT

ADJACENT TO ANY CORRIDOR WALLS.

6. FLOOR ASSEMBLIES ARE NOT REQUIRED TO BE FIRE-RATED UNDER TYPE IIB CONSTRUCTION

(VCC TABLE 601). ALL EXIST. AND NEW FLOOR AND CEILING PENETRATIONS LOCATED IN

RENOVATED SPACES OR CHASES OR INSIDE WALLS THAT ARE ACCESSIBLE DURING THE WORK

OF THIS PROJECT WILL BE SEALED AGAINST THE PASSAGE OF FLAME OR SMOKE (VCC 714.6.1).

THROUGH-PENETRATION FIRESTOPPING ASSEMBLIES ARE NOT REQD.

7. THE 2021 VIRGINIA EXISTING BUILDING CODE (VEBC) IS APPLICABLE TO THIS PROJECT. THIS

PROJECT HAS BEEN DESIGNED AS A LEVEL 2 ALTERATION (VEBC 601.2.2). THE FOLLOWING

VEBC SECTIONS ARE PERTINENT TO THIS PROJECT:

A. 302.1: NEW MATERIALS WILL COMPLY WITH THE 2021 VCC.

B. 404.1: RENOVATIONS WILL MAINTAIN OR IMPROVE THE CURRENT LEVEL OF ACCESSIBILITY.

C. 404.3: THE ALTERATIONS INCLUDE AN AREA CONTAINING A "PRIMARY FUNCTION".

IMPROVEMENTS TO THE ACCESSIBLE ROUTE SERVING THE RENOVATION AREAS,

INCLUDING IMPROVEMENTS TO THE EXIST. TOILET FACILITIES AND WATER COOLERS HAVE

BEEN MADE AS A PART OF AN EARLIER RENOVATION.

D. 601.2.2: THIS PROJECT IS A LEVEL 2 ALTERATION, AS DEFINED IN THIS SECTION.

E. 601.4.6.1: ALTERED COMMERCIAL LIGHTING SHALL COMPLY WITH SECTION C405 OF THE

VECC. SEE ELECTRICAL SHEETS.

F. 602.2: EXISTING LEVELS OF FIRE PROTECTION AND MEANS OF EGRESS PROTECTION WILL

BE MAINTAINED.

G. 602.3: NEW BUILDING ELEMENTS, MATERIALS & METHODS WILL COMPLY WITH THE 2021

VCC.

H. 603.3: NEW CONSTRUCTION COMPONENTS, SYSTEMS & SPACES WILL COMPLY WITH THE

2021 VCC.

I. 603.5: MECHANICAL EXHAUST & VENTILATION AIR IS PROVIDED IN COMPLIANCE WITH THE

2021 VMC. SEE MECHANICAL SHEETS.

8. NO CORRIDORS WITH AN OCCUPANT LOAD GREATER THAN 30 ARE LOCATED WITHIN OR

ADJACENT TO THE RENOVATED AREA. FIRE RESISTANCE RATED CORRIDOR WALLS ARE NOT

REEQUIRED (VCC 1020.1 & TABLE 1020.2

9. EXISTING BUILDING OUTSIDE THE WORK AREA IS NOT RENOVATED FOR COMPLIANCE WITH

VIRGINIA ENERGY CONSERVATION CODE.

10. PORTABLE FIRE EXTINGUISHERS ARE NOT INCLUDED IN THIS PROJECT. PORTABLE FIRE

EXTINGUISHERS WILL BE PROVIDED BY THE OWNER.

11. STRUCTURAL AND SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE WORK OF THIS

PROJECT, AS STRUCTURAL MODIFICATIONS REQUIRING INSPECTIONS ARE NOT INCLUDED IN

THE WORK (VCC SECTION 1705).

SEE ENLARGED PLANS ON

ENGINEERING SHEETS

SERVING

103B5

KITCHEN

115B

KITCHEN

KITCHEN

PASSAGE

103B4

43B

7A

8A

A25

18A5A7BA7

A26 A27

A10

41B

41C

41D

8D

9B

A9

RAMP

UP

8F

8E

8B 8C

19A

A7A

A6

9A 9D

16A

41D1

A27B

A26A

8G

41E

UP

UP

UP

DN DN

UP

DN UP

DNDN

8H

A26B

41D2

41CR

SCALE: 1/16"=1'-0"

PARTIAL BASEMENT KEY PLANPLAN

NORTH

Lic. No. 016372

BUSINESS AREAS

PROJECT OCCUPANT SCHEDULE

SERVING

OF SPACE

195 GSF

KITCHEN COMMERCIAL KITCHEN 740 GSF

FUNCTION

NUMBER

SPACE

150 GROSS

PER OCCUPANT

200 GROSS

FLOOR AREA AREA

2 OCCUPANTS

LOAD

OCCUPANT

103B5

115B 4 OCCUPANTS

6 OCCUPANTS2035 SF

FIRE RESISTANCE RATING OF BUILDING ELEMENTS

BUILDING ELEMENT

PRIMARY STRUCTURAL FRAME 0

BEARING WALLS - EXTERIOR

FLOOR CONSTRUCTION

HOURS

NONBEARING WALLS - EXTERIOR

ROOF CONSTRUCTION

NONBEARING WALLS - INTERIOR

BEARING WALLS - INTERIOR

CORRIDOR WALLS - OCCUPANT LOAD GREATER THAN 30 (VCC 1020.1 & TABLE 1020.2) 1

(FROM VCC TABLE 601)

1. PROJECT OCCUPANT SCHEDULE CONTAINS AREA CALCULATIONS IMPACTING OCCUPANCY ONLY; SOME AREAS ARE LISTED AS NET

AREA CALCULATIONS. SEE T1.1 FOR TOTAL PROJECT AREA.

NAME

SPACE

A2

CLASSIFICATION

USE

A2

SEE ENLARGED PLANS ON

SHEETS D1, D2, A1, A2,

A3, & ENGINEERING

SHEETS

CORRIDOR WALLS - OCCUPANT LOAD LESS THAN 30 (VCC 1020.1 & TABLE 1020.2) 0

REMOVE EXIST.

VCT FLOORING

REMOVE EXIST. FLOOR

TILE & TILE BASE

REMOVE EXIST.RESINOUS

FLOOR COATING

SCALE: 1/4"=1'-0"

PARTIAL FIRST FLOOR PLAN - EXISTING CONDITIONS & DEMOLITION

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

D1

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

F

LO

O R

P

LA

N

E X

IS

T

IN

G

C O

N D

IT

IO

N S

D

E M

O

LI

T

IO

N , D

E M

O

LI

T

IO

N N

O T

E S

PLAN

NORTH

DEMOLITION PLAN NOTES:

1. SEE IMPORTANT NOTES ON SHEET T1 REGARDING ASBESTOS-CONTAINING AND

LEAD-CONTAINING MATERIALS.

2. DRAWINGS ARE BASED ON ORIGINAL BUILDING DRAWINGS & APPROXIMATE FIELD

MEASUREMENTS. VERIFY ALL EXISTING CONDITIONS & DIMENSIONS IN THE FIELD,

PRIOR TO SUBMITTING A BID.

3. PROVIDE METAL STUD & GYP. BD. TEMPORARY CONSTRUCTION WALLS DURING THE

ENTIRE PERIOD OF CONSTRUCTION. ERECT WALLS AS EARLY AS POSSIBLE AT THE

ONSET OF DEMOLITION ACTIVITIES. WHERE TEMPORARY WALLS COINCIDE WITH

INTENDED PERMANENT WALL LOCATIONS, AT CONTRACTOR'S DISCRETION, CONSTRUCT

TEMPORARY WALLS CONFORMING TO THE CONSTRUCTION REQUIREMENTS FOR THE

INTENDED PERMANENT CONSTRUCTION.PROVIDE DOORS WITHIN THE TEMPORARY

BARRIERS AS REQUIRED FOR OWNER AND CONTRACTOR ACCESS.

4. WITHIN THE RENOVATION AREAS SHOWN, REMOVE ALL EXIST. CEILINGS, CEILING

BULKHEADS, DOORS & FRAMES AS INDICATED, PARTITIONS AS INDICATED, WALL

FINISHES, FLOOR FINISHES, DUCTWORK, PLUMBING PIPING, FIXTURES, KITCHEN

EQUIPMENT, CASEWORK, & OTHER MISCELLANEOUS CONSTRUCTION. SEE

STRUCTURAL, PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS FOR ADDITIONAL

DEMOLITION WORK.

5. ALL EXIST. PIPING, DUCTWORK & ELECTRICAL IS NOT SHOWN. PROVIDE MISC.

DEMOLITION AS REQD. FOR PROPER INSTALLATION OF THE WORK OF THIS CONTRACT,

INCL. MECHANICAL, ELECTRICAL & PLUMBING WORK. PERFORM ALL CUTTING, DRILLING

& PATCHING REQUIRED FOR INSTALLATION OF PROPOSED SYSTEMS. SEE MECHANICAL,

ELECTRICAL & PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK.

6. REMOVE ALL EXIST. FASTENERS, ANCHORS, HANGERS, CEILING SUPPORTS,

SURFACE-MOUNTED COMPONENTS, ABANDONED WIRING & CONDUITS, ABANDONED

PIPING, ABANDONED DUCTWORK, ABANDONED EQUIPMENT, & ALL OTHER COMPONENTS

NOT REQD. FOR THE PROPOSED CONSTRUCTION. THESE DRAWINGS DO NOT PURPORT

TO SHOW ALL MISC. DEMOLITION. VERIFY THE SCOPE OF MISC. DEMOLITION WORK IN

THE FIELD.

7. AT ALL WALLS & FLOOR SLABS TO REMAIN, COMPLETELY REMOVE EXIST. CERAMIC TILE

AND SETTING MORTAR, & OTHER FINISHES, DOWN TO MTL. STUDS, CONC. MASONRY OR

CONCRETE, SUITABLE FOR PROPER INSTALLATION OF THE NEW WD. SHEATHING,

BACKING BOARDS, WATERPROOFING SYSTEM, & NEW WALL FINISHES. AT ALL CERAMIC

TILE OR RESINOUS FLOORS, COMPLETELY REMOVE ALL EXIST. TILE OR RESINOUS

FINISHES, GROUT AND MORTAR BEDS, LEAVING THE EXIST. CONCRETE SLAB EXPOSED

AND READY TO RECEIVE THE NEW FINISHES.

5. COMPLETELY REMOVE ALL EXIST. WALL COVERINGS, CHAIR RAIL, & CORNER GUARDS IN

ALL SPACES, UNLESS NOTED OTHERWISE. PATCH, REPAIR & PREPARE WALL SURFACES

AS REQUIRED TO RECEIVE THE SPECIFIED FINISHES.

6. USE EXTREME CARE TO PREVENT DAMAGE TO EXIST. MATERIALS SCHEDULED TO

REMAIN. REPAIR OR REPLACE ALL DAMAGED EXIST. MATERIALS.

7. PROVIDE ALL NECESSARY BRACING & SHORING.

8. REMOVE ALL EXIST. EQUIP. NOT SCHEDULED TO BE REINSTALLED IN THE FINISHED

WORK & DELIVER TO OWNER AT A SPECIFIED LOCATION WITHIN FIVE MILES OF THE

PROJECT SITE. SEE EQUIP. SCHEDULES ON SHEET A3.1 FOR INFORMATION ON ITEMS TO

BE REINSTALLED IN THE FINISHED WORK.

9. REMOVE & STORE ALL EXIST. EQUIP. SCHEDULED TO BE REINSTALLED IN THE FINISHED

WORK. SEE EQUIP. SCHEDULES ON SHEET A3.1 FOR INFORMATION ON ITEMS TO BE

REINSTALLED IN THE FINISHED WORK.

10. OPENINGS TO BE DRILLED OR SAW-CUT INTO EXIST. CONC. SLABS OR WALLS SHALL BE

CAREFULLY SAWN OR CORE-DRILLED TO THE MINIMUM SIZE REQD. FOR THE PROPOSED

CONSTRUCTION. DO NOT EXTEND CUTS PAST OPENING AT CORNERS.

JACK-HAMMERING OF EXIST. CONC. SLABS WILL NOT BE PERMITTED. EXIST. EMBEDDED

REINF. BARS & EMBEDDED ELECT. CONDUITS SHALL BE LOCATED PRIOR TO DRILLING

OR CUTTING, & OPENING LOCATIONS SHALL BE ADJUSTED AS REQD. TO AVOID CUTTING

EXIST. REINF. BARS OR ELECT. CONDUITS, SUBJECT TO THE ADVANCE APPROVAL OF

THE A/E. DO NOT CUT OR DRILL EXIST. BEAMS OR COLUMNS. COORDINATE OPENINGS

WITH SLEEVE SIZES AND WITH APPROVED FIRESTOPPING ASSEMBLIES.

11. EXIST. CONC. MASONRY SHALL BE REMOVED IN FULL SIZE UNITS. WHERE EXIST. CONC.

MASONRY WALLS ARE INDICATED TO BE REMOVED, COMPLETELY REMOVE WALL

CONSTRUCTION FROM TOP OF FLOOR SLAB TO TOP OF WALL, INCL. CONCEALED

ANCHORS, REINFORCING, ELECT. CONDUITS, & OTHER CONCEALED CONSTRUCTION.

PROVIDE WIRING AS REQD. TO MAINTAIN POWER TO ALL EXIST. ELECTRICAL DEVICES

SCHEDULED TO REMAIN - SEE ELECT.

EXIST. WALL TO REMAIN

ITEMS TO BE REMOVED SHOWN

DASHED

MTL. STUD PARTITION TO BE

REMOVED

CFA

HG-1

DHG

HG-2

HG-5

TCW TEMPORARY WALL DURING

CONSTRUCTION

REMOVE EXIST. CERAMIC

TILE WALL FINISH &

CEMENT BD. BACKER

REMOVE EXIST. STAINLESS

STL. WALL PANELS

REMOVE EXIST.

SOUND PANELS

UBO NOTATION:

1/2" = 1'-0"

0 2 53 Lic. No. 016372

EXIST. GLASS-FRONT

BEVERAGE REFRIG. TO

REMAIN (TYP. FOR 4)

REMOVE CMU AS REQD.

FOR PROPOSED DUCT

PENETRATION - SEE MECH.

EXIST. ELECT. PANELBOARD

TO REMAIN

REMOVE EXIST.

DOOR FRAME

REMOVE EXIST.

CASEWORK

REMOVE EXIST.

CASEWORK

REMOVE EXIST.

CASEWORK

REMOVE EXIST. CASEWORK

REMOVE EXIST. CERAMIC

TILE WALL FINISH &

CEMENT BD. BACKER

CAREFULLY COORD. EXTEND OF

VCT DEMOLITION W/ PROPOSED

WALL & FLOORING LOCATIONS (TYP.)

REMOVE EXIST. TILE BASE

EXIST. FLOOR DRAIN - SEE

PLUMB.

REMOVE EXIST.

BUILT-IN SEATING

CMU PARTITION TO BE REMOVED

T C

W T

C W

T C

W T

C W

T C

W T

C W

T C

W T

C W

T C

W T

C W

T C

W T

C W

T C

W

TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW

T C

W T

C W

T C

W T

C W

TCW TCW TCW TCW

REMOVE VCT & CARPET TILE &

PREP FLOOR AS REQD. FOR

ADDITIONAL TILE INSTALLATION -

ADDITIVE BID ITEM NO. 1

EXIST. FLOORING TRANSITION -

CARPET TILE TO VCT

REMOVE EXIST.

CMU PARTITION

TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW

000 ROOM NUMBER

107 115

115B

EXISTING CONDITIONS/DEMOLITION PLAN LEGEND

SCALE: 1/2"=1'-0"

REFLECTED CEILING PLAN - EXISTING CONDITIONS & DEMOLITION

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

D2

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

R E

F

LE

C T

E D

C E

IL

IN

G P

LA

N

E

X

IS

T

IN

G C

O N

D

IT

IO

N

S

D E

M O

LI

T

IO

N

PLAN

NORTH

REMOVE EXIST. GYP. BD.BULKHEAD

EXIST. GYP. BD. BULKHEAD

REMOVE EXIST. WALL-MTD.

LIGHT FIXTURE - SEE ELECT.

BULKHEAD @ ±83" AFF

REMOVE EXIST. SUSP. ACOUST. CLG.

REMOVE EXIST. SUSP. ACOUST.

CLG. AS REQD. FOR PROPOSED

CONST. - PRESERVE & STORE

SUFFICIENT QUANTITIES OF TILE,

TRACK & GRID FOR REINST.

REMOVE EXIST. EX.

HOOD - SEE MECH.

1/2" = 1'-0"

0 2 53

UBO NOTATION:

REMOVE SUSP. BULKHEAD

AS REQD. FOR GREASE DUCT

MODIFICATIONS - SEE MECH.

EXIST. GREASE

DUCT - SEE MECH.

REMOVE EXIST.

WALL-MTD. LIGHT

FIXTURE - SEE ELECT.

Lic. No. 016372

REMOVE EXIST. SUSP. ACOUST. CLG.

MECH. REGISTERS

LAY-IN LIGHT FIXTURES

CAN LIGHT FIXTURE

SMOKE DETECTOR

CLG.-MTD. FIRE ALARM STROBE

WALL-MTD. FIRE ALARM STROBE

WALL-MTD. EMERGENCY LIGHT

WALL-MTD. LIGHT FIXTURE

DEMO RCP LEGEND

ITEMS TO BE REMOVED SHOWN

DASHED

PARTIAL FIRST FLOOR DIMENSIONAL PLAN

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A1

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

P A

R T

IA

L

F

IR

S T

F

LO

O R

D

IM

E N

S

IO

N A

L P

LA

N

, N O

T E

S

PLAN

NORTH

Lic. No. 016372

1/2" = 1'-0"

0 2 53

CFA

HG-1

DHG

HG-2

HG-4

ACCESS.

HAND SINK

EXIST. ELECT.

PANELBOARD

UBO NOTATION:

SERVING

103B5

KITCHEN

115B

KITCHEN

KITCHEN

PASSAGE

103B4

EXIST. GLASS DOOR

DISPLAY REFRIGERATOR

TO REMAIN (TYP. FOR 4)

EXIST. ELECT.

PANELBOARD

3 5/8" 3'-9" 3 5/8" 15'-6"± 3 5/8"

'-7

/2

/8

'-6

/4

/8

'-4

/8

/8

'-1

/2

/8

/8

'-0

/2

/8

4'-0"±

29'-1 1/2"± 3 5/8"

1'-5"± 3 5/8"

TOOTH CMU INTO

EXIST. MASONRY

WALL - SEE STRUCT.

PROVIDE STAINLESS

STEEL HOLLOW MTL.

FRAME IN EXIST.

MASONRY OPENING

3 5/8" 3'-3"

/8

/8

/8

/8

ALIGN MTL. STUD

W/ FACE OF EXIST.

MASONRY

ALIGN MTL. STUD

W/ FACE OF EXIST.

MASONRY

INSTALL CURB FLUSH

W/ OUTER FACE OF

WALL SHEATHING

3 5/8" 1'-5"±3 5/8"

CMU & CONC. LINTEL @

PROPOSED ROUND DUCT

PENETRATION - SEE STRUCT.

INFILL W/ CMU WHERE

DUCTWORK IS

REMOVED - SEE MECH.

'-0

'-0

'-0

'-0

'-0

'-0

'-7

/4

'-4

/2

'-4

/4

8'

-4

/2

'-7

'-9

'-1

/4

/2

ALIGN OUTER FACE OF MTL.

STUD FRAMING W/ EDGE OF

EXIST. FRAMING

'-4

/8

'-4

/8

'-5

'-8

ALIGN OUTER FACE OF MTL.

STUD FRAMING W/ EDGE OF

EXIST. FRAMING

1'-9"

2'-6"

EXIST. CMU WALL

EXIST. WALL

FINISH TO REMAIN

P1

P1 P1

P2

P2

P3

P3

P3

P3

P3

P3

P3 P3

P3

P3

P3

P3

P3

P3

P3

P3

P3 P3

P3

P3

P3

P5

P5

P5P5P5 P5 18"

EXTEND STAINLESS

STL. WALL PANELS

18" PAST EDGE OF

EXHAUST HOOD

EXHAUST HOOD

ABOVE (DASHED)

EXTEND STAINLESS STL.

WALL PANELS 18" PAST

EDGE OF EXHAUST HOOD

8"

P4

P4P4P4

P6

P7

P8

P8

P8

P5

P5

PROPOSED METAL STUD WALL

DIMENSIONAL PLAN LEGEND

EXIST. WALL TO REMAIN

000 ROOM NUMBER - SEE FINISH SCHEDULE

CONC. MASONRY WALL REPAIR

ELECT. PANEL - SEE ELECT.

1. VERIFY ALL EXIST. DIMENSIONS IN THE FIELD & VERIFY THE LAYOUT OF THE MTL. STUD PARTITIONS AS INDICATED ON THE DIMENSIONAL PLANS. REPORT ALL DISCREPANCIES FROM DIMENSIONAL PLANS TO THE A/E, PRIOR TO CONSTRUCTION OF MTL. STUD PARTITIONS. DIMENSIONS NOTED TO BE "CLR." ARE TAKEN FROM

FINISHED SURFACE TO FINISHED SURFACE.

2. PLAN DIMENSIONS INDICATED ARE TAKEN TO ONE OF THE FOLLOWING: (1) THE FACE OF THE EXIST.

CONCRETE MASONRY PARTITIONS, (2) THE FACE OF THE NEW MTL. FRAMING, OR (3) THE FACE OF OUTER LAYER OF WALL SHEATHING. PLAN DIMENSIONS ARE NOT TAKEN TO THE FACE OF THE CERAMIC TILE.

3. METAL STUD FRAMING IS 3 5/8" DEEP, UNLESS OTHERWISE DIMENSIONED ON THE PLANS.

4. SEE WALL TYPE DETAILS ON SHEET A1.1 FOR NUMBERS & TYPES OF WALL SHEATHING LAYERS REQUIRED.

DIMENSIONAL PLAN NOTES:

PROPOSED METAL STUD WALL W/ ACOUSTICAL

BATT INSULATION

WALL SHEATHING TYPE - SEE WALL TYPE DETAILSP#

PT WD. CURB

2'-1 1/2"

A A1A4

B A1A4

C A1A4

D A1A4

E A1A4

F A1A5

G A1A5

H A1A5

K A1A5

J A1A5

L A1A5

M A1A5

N A1A5

103B

M

IN

SIM.

SIM.

A1A6

SIM.

3'-3"

CL

SIM.

02/03/2025

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A7

A1A7

A1A7

A1A7

A1A7

WALL TYPE DETAILS

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A1.1

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

W A

LL

T

Y P

E D

E T

A

IL

S

D O

O R

S C

H E

D U

LE

D E

T A

IL

S

, C O

U N

T E

R T

O P

P

LA

N

Lic. No. 016372

1/2" = 1'-0"

0 2 53

UBO NOTATION:

'-0

2" 3'-0" 2"

STAINLESS STEEL

CASED OPENING FRAME

DOOR TYPES

A

STAINLESS STEEL

DOOR LEAF

B

1. DOOR HARDWARE IS NOT SHOWN ON ELEVATIONS.

DOOR SCHEDULE NOTES:

REMARKSELEV. MAT'LNO. SIZE

102 A

DOOR SCHEDULE

3'-0" x 2'-10" P-LAM / WOOD

NONE -3'-4"± x 7'-4"±

NOTE 1

C/A1/A4

FRAME

CASEWORK

CUSTOM CASED OPENING / STAINLESS STL.

101 B STAINLESS STEEL3'-0" x 7'-0" CASED OPENING / STAINLESS STL.

P1

VCT

5/8" FRT PLYWD.

SUSPENDED CEILING OR

GYP. BD. - SEE SCHED.

EXTEND FRT PLYWD. & CEMENT

BACKERBOARD 6" ABOVE

SUSPENDED CEILING

5/8" CEMENT BACKERBOARD

5/8" CEMENT BACKERBOARD

BELOW PLYWD. - EXTEND 18"

ABOVE FLOOR SLAB

8"

P2

VCT

SUSPENDED CEILING OR

GYP. BD. - SEE SCHED.

EXTEND CEMENT

BACKERBOARD 6" ABOVE

SUSPENDED CEILING

5/8" CEMENT BACKERBOARD

WALL TILE - SEE SCHED.

COVE TILE BASE - SEE SCHED. COVE TILE BASE - SEE SCHED.

WALL TILE - SEE SCHED.

P3

FLOOR TILE - SEE SCHED.

5/8" FRT PLYWD.

SUSPENDED CEILING OR

GYP. BD. - SEE SCHED.

EXTEND FRT PLYWD. & FRP 6"

ABOVE SUSPENDED CEILING

5/8" CEMENT BACKERBOARD

BELOW PLYWD. - EXTEND 18"

ABOVE FLOOR SLAB

8"

FRP - SEE SCHED.

COVE TILE BASE - SEE SCHED.

EXTEND WATERPROOFING

MEMBRANE UP WALL 12" MIN.

CONT. WATERPROOFING MEMBRANE

EXTEND FRP 1" BEHIND COVE BASE

P4

EXIST. FLOOR TILE

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

5/8" FRT PLYWD.

FRT PLYWD. & FRP TERMINATE

9'-4" AFF

5/8" CEMENT BACKERBOARD

BELOW PLYWD. - EXTEND 18"

ABOVE FLOOR SLAB

8"

FRP - SEE SCHED.

COVE TILE BASE - SEE SCHED.

EXTEND FRP 1" BEHIND COVE BASE

P5

FLOOR TILE - SEE SCHED.

5/8" CEMENT BACKERBOARD

SUSPENDED CEILING OR

GYP. BD. - SEE SCHED.

EXTEND CEMENT

BACKERBOARD 24" ABOVE

SUSPENDED CEILING

'-6

4"

STAINLESS STL. WALL

PANELS

COVE TILE BASE - SEE SCHED.

EXTEND WATERPROOFING

MEMBRANE UP WALL 12" MIN.

CONT. WATERPROOFING MEMBRANE

PROVIDE CONT. TRIM @

INTERSECTION OF

STAINLESS STL. PANELS

W/ CEILING

PROVIDE CONT. TRIM @

TOP OF PLYWD. & FRT

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

P6

GYP. BD. CEILING - SEE SCHED.

5/8" CEMENT BACKERBOARD

WALL TILE - SEE SCHED.

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

FLOOR TILE - SEE SCHED.

COVE TILE BASE - SEE SCHED.

EXTEND WATERPROOFING

MEMBRANE UP WALL 12" MIN.

CONT. WATERPROOFING MEMBRANE

P7

GYP. BD. CEILING - SEE SCHED.

5/8" CEMENT BACKERBOARD

WALL TILE - SEE SCHED.

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

FLOOR TILE - SEE SCHED.

COVE TILE BASE - SEE SCHED.

EXTEND WATERPROOFING

MEMBRANE UP WALL 12" MIN.

CONT. WATERPROOFING MEMBRANE1

8"

5/8" FRT PLYWD.

5/8" CEMENT BACKERBOARD

BELOW PLYWD. - EXTEND 18"

ABOVE FLOOR SLAB

P8

GYP. BD. CEILING - SEE SCHED.

(2) LAYERS 5/8" CEMENT

BACKERBOARD

WALL TILE - SEE SCHED.

SEE FLOOR PLAN FOR ADDITIONAL

MASONRY & WALL FRAMING

LOCATIONS & REQUIREMENTS

FLOOR TILE - SEE SCHED.

COVE TILE BASE - SEE SCHED.

EXTEND WATERPROOFING

MEMBRANE UP WALL 12" MIN.

CONT. WATERPROOFING MEMBRANE1

8"

5/8" FRT PLYWD.

5/8" CEMENT BACKERBOARD

BELOW PLYWD. - EXTEND 18"

ABOVE FLOOR SLAB

'-4

2" 3'-4"± 2"

A

DOUBLE ACTING HINGES - ELIASON EASY SWING; PULL HANDLES - HAGER, 3E X 32D

DOUBLE ACTING HINGES - BOMMER IND. INC., #7314, SATIN CHROME FINISH

02/03/2025

2'-10"

'-1

0"

'-0

0' -5

2'-6"

3'-0"

2'-6"

'-5

/4

'-1 1"

'-8

/4

'-4

5'-0"

SCALE: 1/2"=1'-0"

COUNTERTOP PLANPLAN

NORTH

1. ALL DIMENSIONS ARE APPRXIMATE. FIELD VERIFY ALL DETAILS & DIMENSIONS W/ ACTUAL

CASEWORK & EQUIPMENT PROVIDED.

2. PROVIDE SIDE & BACKSPLASHES WHERE INDICATED.

3. PROVIDE SEALANTS @ ALL INTERFACES BETWEEN COUNTERTOPS & BUILT-IN

COMPONENTS & ADJACENT CASEWORK & WALL SURFACES.

COUNTERTOP PLAN NOTES

SOLID SURFACE

COUNTERTOP

SOLID SURFACE

COUNTERTOP

INTEGRAL SOLID

SURFACE

SIDE/BACKSPLASH

8" DIAM. CUT-OUT FOR

UNDER-COUNTER TRASH

CAN - W/ STAINLESS STL.

ESCUTCHEON TRIM RING

UNDERMOUNT HAND SINK &

FAUCET - COORD. SIZE &

LOCATION OF CUTOUTS W/

ACTUAL FIXTURES PROVIDED

CUTOUT FOR BEVERAGE

DISPENSER - COORD.

SIZE & LOCATION W/

ACTUAL EQUIPMENT

PROVIDED

#980 MTL. HALF

WALL

INTEGRAL SOLID

SURFACE

SIDE/BACKSPLASH

SOLID SURFACE

COUNTERTOP

STAINLESS STL.

COUNTERTOP

'-5

INTEGRAL STAINLESS

STL. SIDE/BACKSPLASH

2" DIAM. HOLE W/

STAINLESS STL.

GROMMET

2" DIAM. HOLE W/

STAINLESS STL.

GROMMET

CUT-OUT FOR FRY

PACKAGING CHUTE

CUSTOM STAINLESS

STEEL CASED

OPENING FRAME

OVERLAP EXIST.

MASONRY TO MAXIMIZE

CLR. OPENING SIZE

PARTIAL FIRST FLOOR FINISH PLAN

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A2

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

P A

R T

IA

L

F

IR

S T

F

LO

O R

F

IN

IS

H

E S

P

LA

N , N

O T

E S

PLAN

NORTH

Lic. No. 016372

1/2" = 1'-0"

0 2 53

CFA

HG-1

DHG

HG-2

HG-4

ACCESS.

HAND SINK

EXIST. ELECT.

PANELBOARD

UBO NOTATION:

SERVING

103B5

KITCHEN

115B

KITCHEN

KITCHEN

PASSAGE

103B4

EXIST. GLASS DOOR

DISPLAY REFRIGERATOR

TO REMAIN (TYP. FOR 4)

EXIST. ELECT.

PANELBOARD

EXIST. CMU WALL

EXIST. WALL

FINISH TO REMAIN

EXTEND STAINLESS

STL. WALL PANELS

18" PAST EDGE OF

EXHAUST HOOD

EXHAUST HOOD

ABOVE (DASHED)

EXTEND STAINLESS STL.

WALL PANELS 18" PAST

EDGE OF EXHAUST HOOD

1. ALL TRANSITIONS BETWEEN DISSIMILAR FLOOR MATERIALS ARE TO BE FLUSH & LEVEL.

2. WHERE BASE TILE IS UNDER CASEWORK OR HAS TILE INSTALLED ABOVE, REMOVE BULLNOSE SUCH THAT TOP

OF CUT TILE CAN BE INSTALLED AT 5 1/2" ABOVE FINISHED CONCRETE SLAB.

3. COMPLETELY COVER WALL SURFACES BEHIND CASEWORK WITH SCHEDULE WALL TILE.

4. SEE FINISH & SEALANT SCHEDULES ON SHEET A2.2.

FINISH PLAN NOTES:

PT WD. CURB

A A1A4

B A1A4

C A1A4

D A1A4

E A1A4

F A1A5

G A1A5

H A1A5

K A1A5

J A1A5

L A1A5

M A1A5

N A1A5

N A1A5

103B

A

B

C

D

E

FRP-1 WALL FINISH W/ KT-5B BASE

S-1 WALL FINISH W/ KT-5B BASE

CT-57A WALL FINISH W/ CT-71B BASE

CT-71B BASE AT WOOD CURB

PT-31B PAINT FINISH W/ KT-5B BASE

WALL FINISH LEGEND

B B

B B

B B B B B B B B B B B B B B B B A A A A A A A

A A

AAAAAAAAAAAAA

A A

A A

A A

A A

A A

A

AAAAAAA

A A

A

A

A

A A

A

A A A A A A A A A A A

A A

A A

A

A

A

A A A A A A A A A A A

A

A A

A

AAA

C C C C C C C

F F

F F

F F

F F

F F

F F

F

CCC

C C

C C

C C

C C C C C C C C C C C C C C C C C C

C C

C C

C C

C C C C C C

D D

D D

D D

D D

D D

D D

D D

D

D D

D D

D D

D D

D D

D D

D D

D

D D

D

D D

D

D

E E E E E E

E E

E E

E E

SIM.

SIM.

F CT-45 WALL FINISH W/ CT-71B BASE

SIM.

02/03/2025

ADDITIVE BID ITEM NO. 1 -

ADDITIONAL AREA OF

FLOOR TILE CT-71 (DASHED)

12'-4"±

4'

-1 1"

5'-11"±

'-5

CT-71

KT-5

PARTIAL FIRST FLOOR REFLECTED CEILING PLAN

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A2.1

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

P A

R T

IA

L

F

IR

S T

F

LO

O R

R E

F

LE

C T

E D

C E

IL

IN

G P

LA

N

PLAN

NORTH

Lic. No. 016372

1/2" = 1'-0"

0 2 53

260-R

269-R

211B

211B

UBO NOTATION:

SERVING

103B5

KITCHEN

115B

KITCHEN

KITCHEN

PASSAGE

103B4

FAS

SD

FAS

ACOUST. CLG. @

12'-0"± AFF

FAS

REMOVE & REINSTALL SUSP.

BULKHEAD AS REQD. FOR

GREASE DUCT MODIFICATIONS -

SEE MECH.

GYP. BD. CLG. @ 9'-1"±

AFF - COORD. HEIGHT

W/ EXIST. BULKHEADS

POWER DROP -

SEE ELECT.

REINST. EXIST. ACOUST. CLG.

AGAINST PROPOSED WALL

EXIST. GYP. BD.

BULKHEAD. @ 9'-1"± AFF

STAINLESS STEEL CAP

(CG-3B) ACROSS TOP OF

OPENING

A1A6

SIM.

02/03/2025

ALIGN FINISHED FACE OF

BULKHEAD W/ EXIST.

COLUMN FINISH

MATCH HEIGHT & PROFILE OF

EXIST. GYP. BD. BULKHEAD

REPAIR SUSP. CLG. AS REQD.

FOR GREASE DUCT

MODIFICATIONS - SEE MECH.

STAINLESS STEEL CAP

(CG-3B) ACROSS TOP

OF OPENING

ALIGN FINISHED FACE OF

PROPOSED BULKHEAD W/ EXIST.

BULKHEAD FINISH

1. PROVIDE METAL ACCESS DOORS WHERE INDICATED ON THE DRAWINGS & WHEREVER REQD. FOR ACCESS TO

CONCEALED JUNCTION BOXES, VALVES & ALL EQUIPMENT REQUIRING MAINTENANCE

2. HEIGHTS SHOWN AT CEILINGS ARE TO BOTTOM OF FINISH.

3. SEE FINISH & SEALANT SCHEDULES ON SHEET A2.2.

4. CENTER ALL COMPONENTS THAT ARE LESS THAN 24" X 24" IN A CEILING TILE.

5. DO NOT CUT OR DRILL EXISTING BEAMS, COLUMNS, TRUSSES, HEADERS, OR OTHER STRUCTURAL MEMBERS.

6. ELECTRICAL & MECHANICAL DEVICES ARE SHOWN FOR COORDINATION PURPOSES ONLY. SEE ELECTRICAL &

MECHANICAL DRAWINGS FOR ADDITIONAL WORK REQUIRED FOR ELECTRICAL & MECHANICAL COMPONENTS.

REFLECTED CEILING PLAN NOTES:

ACT-1

PT-31A

OS

OS

OS

FASSD

SD SDOS

OS

OS

Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A2.2

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

F

IN

IS

H

S C

H E

D U

LE

S

Lic. No. 016372

1/2" = 1'-0"

0 2 53

UBO NOTATION:

FINISH MATERIAL SCHEDULE

MARK NOTES

PT-31B

FRP-1

S-1

CT-57A

DESCRIPTION

PROVIDE WALL PANELS, ADHESIVE, MATCHING EDGE & INSIDE CORNER TRIMS, &

OTHER ACCESSORIES AS REQD. PROVIDE MARLITE CORNER GUARDS @ ALL

OUTSIDE CORNERS IN KITCHEN 115 & 115B UNLESS NOTED OTHERWISE.

PROVIDE WALL PANELS, ADHESIVE, MATCHING EDGE & INSIDE & OUTSIDE

CORNER TRIMS, & OTHER ACCESSORIES AS REQD.

FURN. BY INST. BY

GC GC

GC GC

GC GC

GC GC

JOINT WIDTH: 1/8 INCH. GROUT: MAPEI, KERACOLOR U W/ GROUT MAXIMIZER

LATEX ADDITIVE, UNSANDED, 09/GRAY.

CG-3A WALL CORNERS: EXTEND FROM TOP OF FLOOR TO 8'-0" ABOVE ADJACENT

BASE.

CASED OPENINGS: EXTEND FROM TOP OF FLOOR TO HEAD OF OPENING.

GCCUSTOM STAINLESS STEEL CORNER GUARD, 2" X 2" LEGS GC

KT-5

CT-71B

KT-5B

ACT-1 GCCERTAINTEED, PERFORMA / VINYLROCK, #142-CRF-1,

WHITE, 24" X 24"

GC

WALL FINISHES

TRIM

FLOOR & BASE TILE

CEILING FINISHES

PT-31A GCPRIMARY CEILING PAINT, SHERWIN WILLIAMS, PRO MAR

200 ZERO VOC PAINT, SW-7011, NATURAL CHOICE

GC

GRID: STANDARD 15/16", SQUARE LAY-IN, WHITE.

QUARRY TILE, CREATIVE MATERIALS CORPORATION,

GRAY 507, 8" X 8"

GCGC

GCGC

GCGC

INSTALL W/ THINSET MORTAR. JOINT WIDTH: 3/8 INCH. GROUT: MAPEI,

KERAPOXY IEG CQ, 47/CHARCOAL.

CT-71 PORCELAIN TILE, CREATIVE MATERIALS CORPORATION,

LAVA, LIGHT GREY,12" X 12"

GCGC INSTALL ON 45 DEGREE ANGLE. JOINT WIDTH: 3/16 INCH. GROUT: MAPEI,

ULTRACOLOR, 47/CHARCOAL.

CEILING

FINISH SCHEDULE

FLOOR BASE WALLS REMARKS

SPACE NAME &

NO.

CEILING

HEIGHT

-DINING 103 EXIST.EXIST. EXIST. -

-VENDING 103B ACOUST.EXIST. VCT TILETILE 12'-0"±

-PASSAGE 103B4 EX. ACOUST.EXIST. EXIST.EXIST. -

1. PROVIDE VCT, BASE, SUSPENDED ACOUSTICAL CEILINGS & PAINT TO MATCH EXISTING AT

ALL WALL & CEILING LOCATIONS ADJACENT TO THE RENOVATED AREA.

FINISH SCHEDULE NOTES:

MATCH HEIGHT OF EXIST. DINING AREA BULKHEADSSERVING 103B5 GYP. BD.TILE TILETILE 9'-1"±

-KITCHEN 107 ACOUST.EXIST. EXIST.EXIST. -

-KITCHEN 115 EXIST.EXIST. TILE -

-KITCHEN 115B ACOUST.TILE FRPTILE 9'-6"

EXIST.

TILE

EXIST.

FRP

FRP

TILE

EXIST.

EXIST.

ST. STL/FRP

GYP. BD.

TILE

EXIST.

TILE

EXIST,

ST. STL/FRP

NORTH EAST SOUTH WEST

EXIST. EXIST. EXIST.

FRP - MARLITE, STANDARD FRP, P-199, BRIGHT WHITE,

.090" THICK X 4 X 10 PANELS

STAINLESS STEEL WALL PANELS, 18 GAUGE, GRADE 430

SUBWAY WALL TILE, DALTILE, BISCUIT, 4 1/4" X 8 1/2"

PRIMARY WALL PAINT, SHERWIN WILLIAMS, PRO MAR

200 ZERO VOC PAINT, SW-7011, NATURAL CHOICE,

PORCELAIN TILE COVE BASE, CREATIVE MATERIALS

CORPORATION, LAVA, LIGHT GREY,6" X 12"

QUARRY TILE COVE BASE, CREATIVE MATERIALS

CORPORATION, GRAY 507, 6" X 8" COVE

REMOVE BULLNOSE WHEN BASE IS UNDER MILLWORK OR BELOW WALL

TILE. JOINT WIDTH: 3/16 INCH. GROUT: MAPEI, ULTRACOLOR, 47/CHARCOAL.

INSTALL W/ THINSET MORTAR. JOINT WIDTH: 3/8 INCH. GROUT: MAPEI,

KERAPOXY IEG CQ, 47/CHARCOAL.

FINISH: FLAT.

FINISH: EGGSHELL.

CG-3B WALL CORNERS: EXTEND FROM TOP OF FLOOR TO 8'-0" ABOVE ADJACENT

BASE.

CASED OPENINGS: EXTEND FROM TOP OF FLOOR TO HEAD OF OPENING.

GCCUSTOM STAINLESS STEEL WALL END CAP, WALL CAP

PLUS 2" LEG @ ADJACENT WALL FACES

GC

MT-1 OWNERMILLWORK FACE PANELS, CFX PRODUCTS, TRI SMOKE,

T1-7060

OWNER

SS-13 OWNERSOLID SURFACE, AVONITE, FOUNDATIONS MATERIALS

COLLECTION, F1-9865, ARTICA

OWNER

MILLWORK

S-2 STAINLESS STEEL COUNTER 16 GAUGE STAINLESS STEEL OVER (2) LAYERS PLYWD., BRUSHED #4 FINISH, ROUGHNESS OF RA 25 MICRO IN. OR LESS.

PL-40 PLASTIC LAMINATE, WILSONART, SHADOW -

PL-51 PLASTIC LAMINATE, NEVAMAR, RAVEN -

OWNEROWNER

OWNEROWNER

OWNEROWNER

CT-45 GC GC GROUT: MAPEI, KERACOLOR U W/ GROUT MAXIMIZER LATEX ADDITIVE,

UNSANDED, 09/GRAY.

STAINLESS STEEL WALL TILE, CREATIVE MATERIALS

GROUP, VOGUE STAINLESS STEEL, 1"X2" BRICK, 12X12

SHEET

02/03/2025

SEALANT COLOR

SEALANT SCHEDULE

TO MATERIAL

FRONT CASEWORK (PL-1) STILES & RAILS COLOR RITE FIL-STICK BB08

SUBWAY WALL TILE MATCH BASE TILE GROUTBASE TILE

SUBWAY WALL TILE MATCH WALL TILE GROUTWALL TILE (INSIDE CORNERS)

WHITE - BONECOUNTER TOPS / CABINETS (VERTICAL)

STAINLESS STEELSTAINLESS STEEL

WHITE

FRONT CASEWORK PANELS (PL-1)

CEILING GRID

MATERIAL

SUBWAY WALL TILE

SUBWAY WALL TILE

SUBWAY WALL TILE

WHITE - BONEADJACENT MATERIALSOLID SURFACE COUNTER TOP

STAINLESS STEELALL MATERIALSSTAINLESS STEEL CORNER / CAPS

WHITEBASE TILEFRP

WHITEPAINTED DOOR FRAMES

WHITECEILING GRID

CLEARSTAINLESS STEEL FRAMES / SPLASHES / HAND SINKS

CLEARESCUTCHEONS

WHITECEILING GRIDSUBWAY WALL TILE

STAINLESS STEELSTAINLESS STEEL WALL PANELSHOODS / SHROUDS

MATCH BASE TILEUNDERSIDE OF CABINETSBASE TILE

FRP

FRP

FRP

FRP

PARTIAL FIRST FLOOR KITCHEN EQUIPMENT PLAN

Blacksburg, Alliance Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A3

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

K

IT

C H

E N

E Q

U

IP

M E

N T

P

LA

N

PLAN

NORTH

Lic. No. 016372

1/2" = 1'-0"

0 2 53

CFA

HG-1

DHG

HG-2

HG-4

200S-R

200S-R

200U-R

187A

182L

310-R

315W

102C

202A

355F

703L

703M

703S

187C

182L

182L

187D

703S

703M

703L

308E

187B

420-R

300A

301C 182L

300B

300DL

300F

300X

300C 500A-R

122A

182L

120A

187F

438L

564A

420L-R

562A-R

580H

105D

563DL

563Da

105A

560A

187E

522L-R

260-R

522L-R

269-R

562AT-R

1242S

580HT

122B

1242AS

121B

564AT

187G

503B 503T

422A 1114 1244S 443GLT

505VLT

505VLT

505VA

266 524-R 523-R 523-R 523-R 523-R581-R 270

1336 1336 1336

444D 444D-R 444SL-R

1374 431

1384 570

1141G

600A

1330 1332

305-R

620L

211B

211B

1141F

1382 1372F

440C 202A

1382 1372F

440C

442WC

359L

360F

ACCESS.

HAND SINK

360F

359L

1141F

631M

1371F

EXIST. ELECT.

PANELBOARD TO

REMAIN

UBO NOTATION:

SERVING

103B5

KITCHEN

115B

KITCHEN

KITCHEN

PASSAGE

103B4

EXIST. GLASS DOOR

DISPLAY REFRIGERATOR

TO REMAIN (TYP. FOR 4)

EXIST. ELECT.

PANELBOARD TO

REMAIN

1. SEE KITCHEN EQUIPMENT SCHEDULE ON SHEET A3.1.

KITCHEN EQUIPMENT PLAN NOTES:

400L

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A6

A1A7

A1A7

A1A7

A1A7

A1A7

171A

952-R

950-R

02/03/2025

ABOVE

ABOVE

Architects

Virginia

DATE:

PROJECT NO:

Inc.

The

CHECKED BY:

DRAWN BY:

DESIGNED BY:

A3.1

96554

2/03/25

SLL

SLL

DAR / SLL

C H

IC

K

−F

IL

−A R

E N

O V

A T

IO

N

S O

W E

N S

H A

L L

V irg in ia

T e ch

B la ck sb u rg

, V irg in ia

E Q

U

IP

M E

N T

S C

H E

D U

LE

S

Lic. No. 016372

1/2" = 1'-0"

0 2 53

UBO NOTATION:

101 1 SERVING COUNTER MILLWORK PROVIDER 101 REFER TO MANUFACTURER SHOP DRAWINGS

106 1 DESSERT COUNTER MILLWORK PROVIDER 106 REFER TO MANUFACTURER SHOP DRAWINGS

110 1 BACK SERVING COUNTER MILLWORK PROVIDER 110 REFER TO MANUFACTURER SHOP DRAWINGS

120 1 PRIMARY BOARDS COUNTER MILLWORK PROVIDER 120 REFER TO MANUFACTURER SHOP DRAWINGS

EQUIPMENT SCHEDULE

102c 1 MODULAR BEVERAGE CADDY KIT 3 MILLWORK PROVIDER 102c KIT INCLUDES (1) BACKPLATE, (4) LID HOLDERS, AND (1) STRAW HOLDER - (1) DRINK CARRIER TO BE PROVIDED PER RESTAURANT (NOT SHOWN ON DRAWINGS)

105 1 SERVING COUNTER FCC MODEL TBD 105 REFER TO MANUFACTURER SHOP DRAWINGS

105a 1 STAINLESS STEEL BIN HOLDER MILLWORK PROVIDER 105a 105d 1 PACKAGE BAG HOLDER MILLWORK PROVIDER 105d

111 1 STAINLESS STEEL UNDER COUNTER MOUNT HAND SINK VOLLRATH 10101-1 111

120a 1 BUILT-IN BREAD RACK SLIDES MILLWORK PROVIDER 120a INCLUDE 2 BRACKETS PER SET - REFER TO MANUFACTURER SHOP DRAWINGS

121B 1 COUNTER TOP HOT ROUND PACKAGING HOLDER FRANKE 121B

EQUIPMENT SCHEDULE (FUTURE ITEMS)

F444S 1 FUTURE SINGLE THAWING CABINET (32") TRAULSEN RET132EWUT-FHS F444S

F503T 1 FUTURE EGG STATION ANTUNES ES-600R 9300657 F503T

F523 1 FUTURE PRESSURE FRYER HENNY PENNY PFE-500 F523

GRUB HUB MASTER EQUIPMENT SCHEDULE

ITEM NO. Q

U

A N

T

IT

Y

DESCRIPTION OF EQUIPMENT

187A 1 GRUB HUB BEVERAGE KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187a 6 GRUB HUB WALL MOUNT KDS ARM USED TO MOUNT ORDER MONITORS - ORDER MODEL #GH7000-1000 W/ WALL FLEXMOUNT & KC3 BRACKET - NOT SHOWN ON DRAWINGS 187B 1 GRUB HUB DESSERT KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187C 1 GRUB HUB EXPO 1 KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C)

187D 1 GRUB HUB EXPO 2 KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187E 1 GRUB HUB FRY KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187F 1 GRUB HUB PRIMARY BOARDS KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187G 1 GRUB HUB SECONDARY BOARDS KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C)

188 1 GRUB HUB POS KIOSK REFER TO MANUFACTURER SHOP DRAWINGS

ITEM NO. DESCRIPTION OF EQUIPMENT APPROVED MANUFACTURER MODEL ITEM NO. REMARKSQ

U

A N

T

IT

Y

ITEM NO. DESCRIPTION OF EQUIPMENT APPROVED MANUFACTURER MODEL ITEM NO. REMARKSQ

U

A N

T

IT

Y

103 4 CUP DISPENSER SAN JAMAR 103C2410CCFA3

563Da 1 DOUBLE TIER SANDWICH SLIDE STAND MILLWORK PROVIDER 563Da REFER TO MANUFACTURER SHOP DRAWINGS

27807097

122A 1 PACKAGING STORAGE SYSTEM FRANKE 122A27801283

122B 1 XL MENU TAB PACKAGING HOLDER FRANKE 122B27807100

300a 1 MILKSHAKE BASE DISPENSER KANPAK 300aCDE211 300b 1 MILKSHAKE BASE DISPENSER SHELF ALL SOUTHERN FABRICATORS 300b 300c 2 SINGLE-SPINDLE MIXER HAMILTON BEACH 300cHMD300M-CFA 300dL 1 TOPPING DISPENSER / HOLDER ALL SOUTHERN FABRICATORS 300dL7201-NCH 300f 1 DOUBLE SLIMLINE COOKIE DISPENSER SERVER 300f88847

300X 1 DOUBLE BARREL ICE CREAM MACHINE TAYLOR 300X079333BWDC (AIR COOLED)

301C 1 CUP DISPENSER AND LID ORGANIZER WIREWORKS 301CC8504WF

360 2 HAND SINK EAGLE 360YCFA-HSAN-0004-00

400L 1 SINGLE UPRIGHT FREEZER (30") TRAULSEN 400LRLT132WUT-FHS

421 1 DOUBLE UNDERCOUNTER REFRIGERATOR (48") TRAULSEN 421UHT48-LR

422AT 1 REFRIGERATED EQUIPMENT STAND (36") TRAULSEN 422ATTE036HT-ZCF01

431 1 DOUBLE WORKTOP REFRIGERATOR (48") TRAULSEN 431UHT48-ZCF-LR

438L 1 COLD RAIL (33") RANDELL 438LCR9039M-CFA

440C 2 ICE BATH BREADING TABLE DUKE 440CBSTA-120-US

442WC 1 SINGLE UPRIGHT REFRIGERATOR (30") TRAULSEN 442WCRH132W-ZCF16

443GLT 1 SINGLE UPRIGHT REFRIGERATOR (24") TRAULSEN 443GLTRHT132DUT-HHG

444D 1 DOUBLE THAWING CABINET (52 1/8") TRAULSEN 444DRE232N-ZCF02

503b 1 EGG TABLE (48") ATLANTA CUSTOM FABRICATORS 503bCFA-ET-503

503T 1 EGG STATION ANTUNES 503TES-600R-9300657

505va 1 VECTOR OVEN STAND ALTO-SHAAM 505Va5034382-0

505VLT 2 VECTOR OVEN ALTO-SHAAM 505VLTVMC-H3H-106226

560 1 FRY HOLDING STATION BKI 560FW-15BB312007F (FW15-00000018)

560a 1 FRY CARTON DISPENSER ASSEMBLY SAN JAMAR 560aWFD210 & WFD230

563DL 1 DOUBLE TIER SANDWICH SLIDE (38") BKI 563DL2TSM-3824L

564A 1 VISUAL HOT HOLDING CABINET (2X2) MERCO 564AMHC22SNT1T

564AT 1 VISUAL HOT HOLDING CABINET (2X2) MERCO 564ATMHC22SNT1T

570 1 COOLING RACK H&K 570CFA104

580H 1 VISUAL HOT HOLDING CABINET (5X2) MERCO 580HMHC52SNT1T

580HT 1

600 1 MIXER HOBART 600HL200-1

600a 1 MIXER TABLE (30"X20") ATLANTA CUSTOM FABRICATORS 600a3ACF498

620L 1 FOOD PREP TABLE (24"X24") EAGLE 620LT2424STE-BS

649 1 MODIFIED DUAL LINE TABLE (72") EAGLE 649YCFA-DL-0040-00

MOUNT ON MILKSHAKE BASE DISPENSER SHELF

LEFT HAND MOUNT - ORDER (1) #3FRA112

WITH SIDE MOUNTING BRACKETS

HINGE LEFT - ORDER WITH FINISHED BACK & 4 5/8" CASTERS

ORDER WITH 4 1/8" CASTERS

ORDER WITH 4" CASTERS

ORDER WITH 6 1/4" CASTERS & BACKSPLASH TOP

COMPRESSOR ON LEFT

LEAF INCLUDED WITH TABLE - INSTALL IF SHOWN ON DRAWINGS

HINGE RIGHT - PROVIDE FINISHED BACK - ORDER WITH 6 1/4" CASTERS

HINGE STANDARD - ORDER WITH 6 1/4" CASTERS

VISUAL HOT HOLDING CABINET (5X2) MERCO 580HTMHC52SNT1T

INCLUDES GASKET FOR STACKING VECTOR OVENS

HINGE LEFT

ORDER MOUNTING RACK AND 4-PIECE CHUTE KIT

CORD EXITS LEFT

ORDER WITH LIDS/TRAY SEALS, AMBER PANS, AND FALSE BOTTOMS

ORDER WITH LIDS/TRAY SEALS, AMBER PANS, AND FALSE BOTTOMS

ORDER WITH LIDS/TRAY SEALS

ORDER WITH LIDS/TRAY SEALS

ORDER WITH (1) #3HOB405, (1) #3HOB061, (2) #3HOB318, (2) #3HOB319, AND (1) #3HOB058

WITH 5" CASTERS

WITH BACKSPLASH AND 1 5/8" DIAMETER LEGS

WITH BREAD RACKS ON RIGHT - NO BRIDGE

660 4

702 8 703L 5

1114 1 1141F 5

1170 1 1242AS 1 CANTILEVERED SHELVING (30"X36" OVERHEAD ADD) 1242AS METROSEAL GRAY - WITH 86" UPRIGHT AND 30"x36" TOP TIER

LOW-PROFILE LEG INTERMETRO 1170SML30-LP REPLACES STANDARD LEG FOR CANTILEVERED SHELVING

METROSEAL GRAY - MOUNT ON 12" CENTERS AT FOOD PREP AREA - NOT SHOWN ON PLAN

VERTICAL SHELF DIVIDER (18"D X 8"H) INTERMETRO 1141FDD18FC FOR SOLID SHELF - MOUNT ON 12" CENTERS AT FOOD PREP AREA - NOT SHOWN ON PLAN CANTILEVERED SHELVING TASK LIGHT BRACKET (48") INTERMETRO 1114DD9528 MOUNT TO UPPER TIER OF SHELVING UNIT FOR TASK LIGHT

LARGE CONDIMENT BIN CARLISLE 703L104976GY

WALL MOUNT SINGLE RAIL ULINE 702H-4681 SUPPORT FOR CONDIMENT BINS

PAPER TOWEL DISPENSER SAN JAMAR 660T1400REBKB RE: ARCHITECTURAL SHEETS FOR DETAILS ON MOUNTING HEIGHTS AND LOCATIONS

703M 5 MEDIUM…