IFB 306852501_Addendum 3.pdf
PDF 12 MB Posted
- Attached to
- Owens Hall Chick-fil-A Renovations
- Solicitation number
- 85722
- Issued by
- Middlesex County, Virginia
About this file
This is Addendum 3 to IFB #306852501 issued by Virginia Polytechnic Institute and State University (Virginia Tech) for renovations to the Chick-fil-A location in Owens Hall. The project involves complete demolition of the existing Chick-fil-A venue and construction of a new restaurant with storage area, all within the existing building. Key changes in the addendum include the addition of an additive bid item for additional tile area at the front service counter, requirement for professional cleaning at project end, and extension of the bid due date from February 14, 2025 to February 21, 2025 at 2:00 PM, with bid opening via Zoom on February 24, 2025. The project requires substantial completion by September 1, 2025, with final completion within 30 days thereafter.
The contractor must achieve a 50% small business participation goal for the project. The work requires temporary containment walls with Level 3 finish on the public side during construction since work will occur during fall classes. The scope includes installation of new equipment, fixtures, finishes, mechanical systems, and utilities. The contractor is responsible for installing owner-furnished FF&E/millwork. Detailed equipment schedules, mechanical drawings, and electrical specifications are provided to guide installation requirements for kitchen equipment, utilities, and building systems.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VIRGINIA POLYTECHNIC INSTITUTE AND STATE UNIVERSITY
PROCUREMENT DEPARTMENT
ADDENDUM NO. 3
DATE: February 11, 2025 TO: All Offerors FROM: Ted Alt, Buyer Specialist TOTAL PAGE(S): 2 pages (not including attachments) SOLICITATION TITLE: Owens Hall Chick-fil-A Renovations
SOLICITATION NUMBER: 306852501
I. CLARIFICATIONS AND ADDITIONAL INFORMATION
1. An Additive has been added to the bid form. Please use the updated bid form, attached as Exhibit A, when submitting your bid.
2. See sheet D1 for schematic location of Temporary Wall required during construction.
3. The Contractor shall hire professional cleaning company and end of project for cleaning all areas affected by construction activities.
4. Equipment Schedule can be found on Sheet A3.1 of the Drawings and additional information found on the engineering sheets.
5. The Owner shall furnish FF&E/Millwork. Contractor shall install all FF&E/Millwork.
6. Due date is being moved:
Previous Date: February 14, 2025, at 2:00 PM New Date: February 21, 2025, at 2:00 PM
The bid opening will take place on February 24, 2025, at 2:00 PM via Zoom. Details can be found in the Notice of Advertisement.
Clarifications on Drawings:
1. The revised drawings attached as Exhibit B dated February 3, 2025, replace the previously issued drawings in their entirety.
II. REQUESTS FOR INFORMATION
1. Are there any bidder qualifications we should be aware of?
Virginia Tech Response: See bid documents.
2. Who is responsible for providing sink?
Virginia Tech Response: See Equipment Schedule on Sheet A3.1 and additional information found on the plumbing sheets.
3. Can you provide information on the equipment schedule as to what is owner provided, contractor provided, or franchise provided, and who is to install these items?
Virginia Tech Response: See updated Equipment Schedule on Sheet A3.1
4. Sections 1-12 on page A6 have tags stating that they come from page A1. I have found no designation on page A1 for these sections. Can you provide information on where they came from?
Virginia Tech Response: Tags have been added on Sheet A1
5. Sink S-1 has no tag to link it to the equipment schedule. Can you provide information on the sink and whether it is provided by the owner or not?
Virginia Tech Response: Sink S-1 is specified on Sheet P2. Sink S-1 and associated faucet for sink S-1 are to be provided by the contractor. See specifications on sheet P2 and Equipment Schedule on Sheet A3.1 for information on other required sinks and faucets.
6. There are several pieces of equipment that are not defined in the schedules on
A3.1. for example 702,703S,703L,703M,421,300a, & 300X are all not defined in the equipment schedules. Can we have the information on the remaining equipment tags?
Virginia Tech Response: See updated Equipment Schedule on Sheet A3.1
7. On page P2, there is a note under kitchen equipment that says, “Coordinate with owner kitchen equipment and make water, waste, and vent pipe connections.
Coordinate locations, dimensions, connection sizes and details with equipment installation instructions. See owner equipment drawings for equipment identification and plumbing schedule indicating equipment connections. Plumber shall provide devices such as stops, risers, thermostatic mixing valves, traps, pressure reducing valves, fittings, and other plumbing accessories for a complete installation of kitchen equipment.” When will we have access to these?
Virginia Tech Response: Kitchen equipment requiring plumbing connections is indicated on the plumbing drawings.
8. What is the power source for fryers (electric, natural gas, etc.)?
Virginia Tech Response: See electrical drawings
Exhibit A Updated Bid Form
Standard Bid Form Format
BID FORM
(DGS Rev. 07/22) (VT Rev. 2/24)
DATE:
PROJECT: Owens Hall Chick-fil-A Renovations Blacksburg, VA
IFB #: 306852501
To: Virginia Polytechnic Institute and State University North End Center, Suite 2100
300 Turner Street, NW Blacksburg, VA 24061
In compliance with and subject to your Invitation for Bids and the documents therein specified, all of which are incorporated herein by reference, the undersigned bidder proposes to furnish all labor, equipment, and materials and perform all work necessary for construction of this project, in accordance with the Plans and Specifications dated November 20, 2024, and the Addenda noted below, as prepared by The Architects Alliance Inc. for the consideration of the following amount:
BASE BID (including the following parts but excluding work in Additive Bid Items):
TOTAL BASE BID AMOUNT IS:
_______________________________________________________ DOLLARS ($ )
ADDITIVE BID ITEM 1: Lump sum price for all work to add additional tile area at front service counter, complete, in accordance with the drawings and specifications is
____________________________________________ Dollars ($ )
Contract award will be based on the TOTAL BASE BID AMOUNT shown above (including any properly submitted bid modifications) plus as many Additive Bid Items taken in sequence as the Owner in its discretion decides to award.
The bidder has relied upon the following public historical climatological records:
NOAA for Blacksburg, VA
Code of Virginia, § 2.2-4376.2 shall be applicable to the Work of the Contract.
The undersigned understands that time is of the essence and agrees that the date for Substantial Completion of the entire project shall be on or before September 1, 2025, and Final Completion shall be achieved within 30 consecutive calendar days after the date of Substantial Completion as determined by the A/E.
Acknowledgment is made of receipt of the following Addenda:
If notice of acceptance of this bid is given to the undersigned within 30 days after the date of opening of bids, or any time thereafter before this bid is withdrawn, the undersigned will execute and deliver a contract in the prescribed form (Commonwealth of Virginia Contract Between Owner and Contractor, Form CO-9) within 10 days after the contract has been presented to him for signature. The required payment and performance bonds, on the forms prescribed, shall be delivered to the Owner along with the signed Contract.
Immigration Reform and Control Act of 1986: The undersigned certifies that it does not and shall not during the performance of the Contract for this project violate the provisions of the Federal Immigration Reform and Control Act of 1986, which prohibits employment of illegal aliens, or knowingly employ an unauthorized alien as defined in the Federal Immigration Reform and Control Act of 1986.
DISQUALIFICATION OF CONTRACTORS: By signing this bid or proposal, the undersigned certifies that this Bidder or any officer, director, partner or owner is not currently barred from bidding on contracts by any Agency of the Commonwealth of Virginia, or any public body or agency of another state, or any agency of the federal government, nor is this Bidder a subsidiary or affiliate of any firm/corporation that is currently barred from bidding on contracts by any of the same. We have attached an explanation of any previous disbarment(s) and copies of notice(s) of reinstatement(s).
DISQUALIFICATION FOR WAGE THEFT: By signing this bid or proposal, the undersigned certifies that this Bidder or their proposed subcontractor(s), or any officer, director, partner or owner thereof is not currently in litigation, under investigation, or criminal indictment for wage theft on contracts by any Agency of the Commonwealth of Virginia, or any public body or agency of another state, or any agency of the federal government.
The apparent low bidder shall submit, within two (2) business days of the bid opening, a complete subcontracting plan listing all tiered subcontractors on the DGS-30-360 form, which can be downloaded from: https://dgs.virginia.gov/search/documents-and-forms/. In addition, Bidder shall identify all subcontractors that are Small, Women Owned and Minority Owned firms.
Agency Small Business Participation Goal: % 50
Contractor’s Proposed Small Business Participation: % ___________ (required)
Either the undersigned or one of the following individuals, if any, is authorized to modify this bid prior to the deadline for receipt of bids by writing the modification and signing his name on the face of the bid, on the envelope in which it is enclosed, on a separate document, or on a document which is telefaxed to the Owner:
https://dgs.virginia.gov/search/documents-and-forms/
I certify that the firm name given below is the true and complete name of the bidder and that the bidder is legally qualified and licensed by the Virginia Department of Professional and Occupational Regulation, Board for Contractors, to perform all Work included in the scope of the Contract.
Virginia License No.: ______________ Bidder: ______________________________
(Name of Firm)
Contractor Class: ________________ By:___________________________________ (Signature)
By:____________________________________ (Print Name)
Email: _________________________________ (Print Email Address)
Specialty: _______________________ Valid until: ______________________
FEIN/SSN: _____________________ Title: _______________________________
If General Partnership (List Partners' Names)
Business Address:
Telephone # ________________________
FAX # _______________________________
If Corporation, affix Corporate Seal & list State of Incorporation
State: _____________________________
(Affix Seal)
Virginia State Corporation Commission ID No.: _______________; or
If Contractor is a foreign business entity not required to be authorized to transact business in the Commonwealth under Titles 13.1 or 50 of the Code of Virginia, or as otherwise required by law, please provide an explanation as to why such entity is not required to be so authorized: ____________________
Exhibit B Updated Drawings dated February 3, 2025
LOCATION MAP:
Virginia Polytechnic Institute & State University Commonwealth of Virginia 150 Kent Street, Blacksburg, VA 24061
O W
E N
S H
A
LL
C H
IC
K
-F
IL
-A R
E N
O V
A T
IO
N
S
SOUTHGATE DRIVE
TECH
VIRGINIA
ROAD
M
AIN STREET
AIR
PO
R T
460 BYPASS
U .S. R
O U
TE
TECH
CORPORATE
PRICESFORK
R O
AD
DRIL
L
FIE
LD
AIRPORT
VIRGINIA
RESEARCH
CENTER
W
ASHIN
GTON S
TREET
W
EST CAM
PU
S
D R
IV
E
N O
R T
H D
RAPER RD
ROANOKE ST.
SEAL:
CODE INFORMATION: INDEX OF DRAWINGS:
Inc.
Alliance Architects The
ARCHITECT:
VT Work Order #: 25-688542
APPLICABLE CODES:
USE GROUP:
CONSTRUCTION CLASSIFICATION:
VUSBC OCCUPANCY:
DESIGN LIVE LOADS:
TOTAL BUILDING FLOOR AREA:
TOTAL RENOVATION AREA:
FIRE SUPPRESSION SYSTEM:
FIRE ALARM SYSTEM:
T1 LOCATION MAP, CODE INFORMATION, HAZARDOUS MATERIALS NOTES
LS1 KEY PLANS, CODE ANALYSIS NOTES, SCHEDULES
D1 FLOOR PLAN - EXISTING CONDITIONS & DEMOLITION, DEMOLITION NOTES
D2 REFLECTED CEILING PLAN - EXISTING CONDITIONS & DEMOLITION
A1 PARTIAL FIRST FLOOR DIMENSIONAL PLAN, NOTES
A1.1 WALL TYPE DETAILS, DOOR SCHEDULE & DETAILS, COUNTERTOP PLAN
A2 PARTIAL FIRST FLOOR FINISHES PLAN, NOTES
A2.1 PARTIAL FIRST FLOOR REFLECTED CEILING PLAN
A2.2 FINISH SCHEDULES
A3 PARTIAL FIRST FLOOR KITCHEN EQUIPMENT PLAN
A3.1 KITCHEN EQUIPMENT SCHEDULES
A4 INTERIOR ELEVATIONS
A5 INTERIOR ELEVATIONS
A6 SECTIONS & DETAILS
A7 DETAILS
A8 EQUIPMENT DETAILS
A9 OUTLINE SPECIFICATIONS
A10 OUTLINE SPECIFICATIONS
S1 STRUCTURAL DETAILS, NOTES
MD1 PARTIAL FIRST FLOOR PLAN - MECHANICAL DEMOLITION, NOTES
M1 PARTIAL FIRST FLOOR PLAN - MECHANICAL
M2 MECHANICAL OUTLINE SPECIFICATIONS, LEGENDS
PD1 PARTIAL FIRST FLOOR PLAN - PLUMBING DEMOLITION, DEMOLITION NOTES
P1 PARTIAL FIRST FLOOR PLAN - PLUMBING, NOTES
P2 PLUMBING OUTLINE SPECIFICATIONS, LEGENDS
ED1 ELECTRICAL FLOOR PLAN - EXIST. CONDITIONS/DEMOLITION, NOTES
ED2 ELECTRICAL REFLECTED CEILING PLAN - EXIST. CONDITIONS/DEMOLITION
ED3 EXISTING PANEL SCHEDULES
E1 ELECTRICAL NOTES, ELECTRICAL OUTLINE SPECIFICATIONS
E2.1 PARTIAL FIRST FLOOR POWER, DATA & EQUIPMENT PLAN
E2.2 EQUIPMENT SCHEDULE - ELECTRICAL
E3 PARTIAL FIRST FLOOR REFLECTED CEILING PLAN - ELECTRICAL
E4 MODIFIED PANEL SCHEDULES
LEAD-CONTAINING PAINT NOTES:
ASBESTOS-CONTAINING MATERIALS NOTES:
ASBESTOS-CONTAINING MATERIALS OR PAINTS CONTAINING LEAD SHALL NOT BE USED IN ANY FORM ON STATE PROPERTY (VA TECH).
ALL INFORMATION RELATED TO ASBESTOS-CONTAINING AND LEAD-CONTAINING MATERIALS IS PROVIDED BY VIRGINIA TECH SAFETY COMPLIANCE OFFICER, WHO SHALL BE CONTACTED FOR ALL DETAILS AND PROCEDURES RELATED TO SUCH MATERIALS, AT 540.231.9397.
OWENS HALL CHICK-FIL-A RENOVATIONS
Gibson Engineering, LLC
ELECTRICAL ENGINEER:
Mann & Associates Inc.
MECHANICAL ENGINEER:
VT IFB #: 306852501
AN ASBESTOS INSPECTION WAS PERFORMED AND NO ACM WAS FOUND. THE ASBESTOS INSPECTION REPORT IS INCLUDED IN THE INVITATION FOR BIDS. IF A SUSPECT ASBESTOS-CONTAINING MATERIAL IS ENCOUNTERED IN THE COURSE OF THIS WORK, WORK SHALL STOP IMMEDIATELY AND THE SAFETY COMPLIANCE OFFICER SHALL BE CONTACTED AT 540.231.9397.
A LEAD-CONTAINING PAINT INSPECTION WAS PERFORMED AND NO LEAD CONTAINING PAINT WAS FOUND. THE LEAD-CONTAINING PAINT INSPECTION REPORT IS INCLUDED IN THE INVITATION FOR BIDS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR'S USE AND MAY NOT BE ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY & HEALTH REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. IF A SUSPECT LEAD-CONTAINING MATERIAL IS ENCOUNTERED IN THE COURSE OF THIS WORK, WORK SHALL STOP IMMEDIATELY AND THE SAFETY COMPLIANCE OFFICER SHALL BE CONTACTED AT
540.231.9397. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
2021 Virginia Uniform Statewide Building Code (VUSBC), Part II, adopted January 18, 2024, also known as the 2021 Virginia Existing Building Code (VEBC - Level 2 Alteration), and incorporating the 2021 International Building Codes with Virginia amendments
Americans with Disabilities Act 2010 ADA Standards for Accessible Design (ADA 2010), published September 15, 2010, and adopted March 1, 2011
Virginia Accessibility Code 2017 Virginia Plumbing Code 2021 Virginia Mechanical Code 2021 Virginia Electrical Code 2020 National Fire Alarm and Signaling Code - NFPA 72, 2019 Edition Standard for Wet Chemical Extinguishing Systems - NFPA 17A, 2021 Edition VT Construction and Professional Services Manual (CPSM), 2020 Edition, adopted January 24, 2020 VT Design and Construction Standards Manual, effective July 1, 2023
B (Business), A2 (Assembly) - Non Separated Mixed Use - Unchanged IIB - Unchanged Unchanged
Not Applicable - No Structural Modifications required for this Project
97,688± GSF
1,200± GSF
Automatic Fire Extinguishing System (at Kitchen Exhaust Hoods) Automatic Fire Alarm System
DATE:
TAA PROJECT NO.: 96554
February, 3, 2025
VT Building #: 0195
UBO NOTATION:
PROJECT
SITE
SHANE LARKIN
Lic. No. 016372
THE CONTRACTOR SHALL COMPLY WITH "VIRGINIA TECH'S SAFETY REQUIREMENTS FOR CONTRACTORS AND SUBCONTRACTORS PROGRAM", WHICH IS INCORPORATED IN THESE DOCUMENTS BY REFERENCE. COPIES OF THIS PROGRAM ARE AVAILABLE FROM THE
OWNER, OR MAY BE DOWNLOADED AT <WWW.EHS.VT.EDU>
Day & Kinder Consulting Engineers PLLC
STRUCTURAL ENGINEER:
02/03/2025
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
K E
Y P
LA
N
S , C
O D
E A
N A
LY
S
IS
N
O T
E S
, S C
H E
D U
LE
S
O W
E N
S H
A L
L C
H
IC
K −F
IL
−A
R E
N O
V A
T
IO
N S
V
IR
G
IN
IA
P
O
LY
T E
C H
N
IC
IN
S
T
IT
U T
E
S T
A T
E U
N
IV
E R
S
IT
Y
SLL
SLL
SLL
96554
2/03/25
LS1
1/16" = 1'-0"
0 2 4 6 10 20 40
KEY PLAN NOTES:
1. KEY PLAN DRAWINGS ARE SCHEMATIC, AND
ARE NOT DRAWN ACCURATELY TO SCALE. SEE
EXISTING CONDITIONS/DEMOLITION FLOOR
PLANS ON SHEETS D1 & D2 FOR MORE DETAILS
OF EXISTING CONDITIONS.
UBO NOTATION:
100D
100J
B25
B1
B5B6
B8
107B
107A
107C
B10
B12
B11
B13
B14
B15
114A
114B
B16
B17
100A 100B
100H
100F
100E
B21
B26
100C
100K
B22
100G
B24
100L
B29
101E 101D 101B
101C
104 102 102
B27B31
L O
A D
IN
G
D O
C K
B23
B20
B19
B18
113A
101F
B32
B20A
B5A
103C 103B
103A
B4
B9
115A
108A
101A
117A
101G
113B
B33
DN
DNUP
DN
UP
UP UP
UP
UP
UP
UP
102104
UP
103B1
103B3
103B2
UP
SCALE: 1/16"=1'-0"
FIRST FLOOR KEY PLANPLAN
NORTH
CODE ANALYSIS NOTES:
1. THE EXISTING BUILDING USE GROUP OF B AND A2 IS NOT CHANGED BY THIS PROJECT.
2. THE EXISTING BUILDING CONSTRUCTION CLASSIFICATION (ASSUMED IIB) IS NOT CHANGED BY
THIS PROJECT.
3. THE EXISTING BUILDING HEIGHT AND AREA ARE NOT CHANGED BY THIS PROJECT.
4. THE EXISTING BUILDING IS NOT SPRINKLERED. THE EXISTING BUILDING HAS AN AUTOMATIC
FIRE ALARM SYSTEM, WHICH WILL BE RE-CONFIGURED WITHIN THE RENOVATION AREAS AS
REQD. FOR COMPLIANCE WITH THE 2021 VCC.
5. THE CORRIDOR WALLS ARE REQD. TO HAVE A 1 HOUR FIRE RATING UNDER CURRENT CODE
(VCC TABLE 1020.1). THE RENOVATION AREA DOES NOT INCLUDE ANY CORRIDORS AND IS NOT
ADJACENT TO ANY CORRIDOR WALLS.
6. FLOOR ASSEMBLIES ARE NOT REQUIRED TO BE FIRE-RATED UNDER TYPE IIB CONSTRUCTION
(VCC TABLE 601). ALL EXIST. AND NEW FLOOR AND CEILING PENETRATIONS LOCATED IN
RENOVATED SPACES OR CHASES OR INSIDE WALLS THAT ARE ACCESSIBLE DURING THE WORK
OF THIS PROJECT WILL BE SEALED AGAINST THE PASSAGE OF FLAME OR SMOKE (VCC 714.6.1).
THROUGH-PENETRATION FIRESTOPPING ASSEMBLIES ARE NOT REQD.
7. THE 2021 VIRGINIA EXISTING BUILDING CODE (VEBC) IS APPLICABLE TO THIS PROJECT. THIS
PROJECT HAS BEEN DESIGNED AS A LEVEL 2 ALTERATION (VEBC 601.2.2). THE FOLLOWING
VEBC SECTIONS ARE PERTINENT TO THIS PROJECT:
A. 302.1: NEW MATERIALS WILL COMPLY WITH THE 2021 VCC.
B. 404.1: RENOVATIONS WILL MAINTAIN OR IMPROVE THE CURRENT LEVEL OF ACCESSIBILITY.
C. 404.3: THE ALTERATIONS INCLUDE AN AREA CONTAINING A "PRIMARY FUNCTION".
IMPROVEMENTS TO THE ACCESSIBLE ROUTE SERVING THE RENOVATION AREAS,
INCLUDING IMPROVEMENTS TO THE EXIST. TOILET FACILITIES AND WATER COOLERS HAVE
BEEN MADE AS A PART OF AN EARLIER RENOVATION.
D. 601.2.2: THIS PROJECT IS A LEVEL 2 ALTERATION, AS DEFINED IN THIS SECTION.
E. 601.4.6.1: ALTERED COMMERCIAL LIGHTING SHALL COMPLY WITH SECTION C405 OF THE
VECC. SEE ELECTRICAL SHEETS.
F. 602.2: EXISTING LEVELS OF FIRE PROTECTION AND MEANS OF EGRESS PROTECTION WILL
BE MAINTAINED.
G. 602.3: NEW BUILDING ELEMENTS, MATERIALS & METHODS WILL COMPLY WITH THE 2021
VCC.
H. 603.3: NEW CONSTRUCTION COMPONENTS, SYSTEMS & SPACES WILL COMPLY WITH THE
2021 VCC.
I. 603.5: MECHANICAL EXHAUST & VENTILATION AIR IS PROVIDED IN COMPLIANCE WITH THE
2021 VMC. SEE MECHANICAL SHEETS.
8. NO CORRIDORS WITH AN OCCUPANT LOAD GREATER THAN 30 ARE LOCATED WITHIN OR
ADJACENT TO THE RENOVATED AREA. FIRE RESISTANCE RATED CORRIDOR WALLS ARE NOT
REEQUIRED (VCC 1020.1 & TABLE 1020.2
9. EXISTING BUILDING OUTSIDE THE WORK AREA IS NOT RENOVATED FOR COMPLIANCE WITH
VIRGINIA ENERGY CONSERVATION CODE.
10. PORTABLE FIRE EXTINGUISHERS ARE NOT INCLUDED IN THIS PROJECT. PORTABLE FIRE
EXTINGUISHERS WILL BE PROVIDED BY THE OWNER.
11. STRUCTURAL AND SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE WORK OF THIS
PROJECT, AS STRUCTURAL MODIFICATIONS REQUIRING INSPECTIONS ARE NOT INCLUDED IN
THE WORK (VCC SECTION 1705).
SEE ENLARGED PLANS ON
ENGINEERING SHEETS
SERVING
103B5
KITCHEN
115B
KITCHEN
KITCHEN
PASSAGE
103B4
43B
7A
8A
A25
18A5A7BA7
A26 A27
A10
41B
41C
41D
8D
9B
A9
RAMP
UP
8F
8E
8B 8C
19A
A7A
A6
9A 9D
16A
41D1
A27B
A26A
8G
41E
UP
UP
UP
DN DN
UP
DN UP
DNDN
8H
A26B
41D2
41CR
SCALE: 1/16"=1'-0"
PARTIAL BASEMENT KEY PLANPLAN
NORTH
Lic. No. 016372
BUSINESS AREAS
PROJECT OCCUPANT SCHEDULE
SERVING
OF SPACE
195 GSF
KITCHEN COMMERCIAL KITCHEN 740 GSF
FUNCTION
NUMBER
SPACE
150 GROSS
PER OCCUPANT
200 GROSS
FLOOR AREA AREA
2 OCCUPANTS
LOAD
OCCUPANT
103B5
115B 4 OCCUPANTS
6 OCCUPANTS2035 SF
FIRE RESISTANCE RATING OF BUILDING ELEMENTS
BUILDING ELEMENT
PRIMARY STRUCTURAL FRAME 0
BEARING WALLS - EXTERIOR
FLOOR CONSTRUCTION
HOURS
NONBEARING WALLS - EXTERIOR
ROOF CONSTRUCTION
NONBEARING WALLS - INTERIOR
BEARING WALLS - INTERIOR
CORRIDOR WALLS - OCCUPANT LOAD GREATER THAN 30 (VCC 1020.1 & TABLE 1020.2) 1
(FROM VCC TABLE 601)
1. PROJECT OCCUPANT SCHEDULE CONTAINS AREA CALCULATIONS IMPACTING OCCUPANCY ONLY; SOME AREAS ARE LISTED AS NET
AREA CALCULATIONS. SEE T1.1 FOR TOTAL PROJECT AREA.
NAME
SPACE
A2
CLASSIFICATION
USE
A2
SEE ENLARGED PLANS ON
SHEETS D1, D2, A1, A2,
A3, & ENGINEERING
SHEETS
CORRIDOR WALLS - OCCUPANT LOAD LESS THAN 30 (VCC 1020.1 & TABLE 1020.2) 0
REMOVE EXIST.
VCT FLOORING
REMOVE EXIST. FLOOR
TILE & TILE BASE
REMOVE EXIST.RESINOUS
FLOOR COATING
SCALE: 1/4"=1'-0"
PARTIAL FIRST FLOOR PLAN - EXISTING CONDITIONS & DEMOLITION
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
D1
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
F
LO
O R
P
LA
N
E X
IS
T
IN
G
C O
N D
IT
IO
N S
D
E M
O
LI
T
IO
N , D
E M
O
LI
T
IO
N N
O T
E S
PLAN
NORTH
DEMOLITION PLAN NOTES:
1. SEE IMPORTANT NOTES ON SHEET T1 REGARDING ASBESTOS-CONTAINING AND
LEAD-CONTAINING MATERIALS.
2. DRAWINGS ARE BASED ON ORIGINAL BUILDING DRAWINGS & APPROXIMATE FIELD
MEASUREMENTS. VERIFY ALL EXISTING CONDITIONS & DIMENSIONS IN THE FIELD,
PRIOR TO SUBMITTING A BID.
3. PROVIDE METAL STUD & GYP. BD. TEMPORARY CONSTRUCTION WALLS DURING THE
ENTIRE PERIOD OF CONSTRUCTION. ERECT WALLS AS EARLY AS POSSIBLE AT THE
ONSET OF DEMOLITION ACTIVITIES. WHERE TEMPORARY WALLS COINCIDE WITH
INTENDED PERMANENT WALL LOCATIONS, AT CONTRACTOR'S DISCRETION, CONSTRUCT
TEMPORARY WALLS CONFORMING TO THE CONSTRUCTION REQUIREMENTS FOR THE
INTENDED PERMANENT CONSTRUCTION.PROVIDE DOORS WITHIN THE TEMPORARY
BARRIERS AS REQUIRED FOR OWNER AND CONTRACTOR ACCESS.
4. WITHIN THE RENOVATION AREAS SHOWN, REMOVE ALL EXIST. CEILINGS, CEILING
BULKHEADS, DOORS & FRAMES AS INDICATED, PARTITIONS AS INDICATED, WALL
FINISHES, FLOOR FINISHES, DUCTWORK, PLUMBING PIPING, FIXTURES, KITCHEN
EQUIPMENT, CASEWORK, & OTHER MISCELLANEOUS CONSTRUCTION. SEE
STRUCTURAL, PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS FOR ADDITIONAL
DEMOLITION WORK.
5. ALL EXIST. PIPING, DUCTWORK & ELECTRICAL IS NOT SHOWN. PROVIDE MISC.
DEMOLITION AS REQD. FOR PROPER INSTALLATION OF THE WORK OF THIS CONTRACT,
INCL. MECHANICAL, ELECTRICAL & PLUMBING WORK. PERFORM ALL CUTTING, DRILLING
& PATCHING REQUIRED FOR INSTALLATION OF PROPOSED SYSTEMS. SEE MECHANICAL,
ELECTRICAL & PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK.
6. REMOVE ALL EXIST. FASTENERS, ANCHORS, HANGERS, CEILING SUPPORTS,
SURFACE-MOUNTED COMPONENTS, ABANDONED WIRING & CONDUITS, ABANDONED
PIPING, ABANDONED DUCTWORK, ABANDONED EQUIPMENT, & ALL OTHER COMPONENTS
NOT REQD. FOR THE PROPOSED CONSTRUCTION. THESE DRAWINGS DO NOT PURPORT
TO SHOW ALL MISC. DEMOLITION. VERIFY THE SCOPE OF MISC. DEMOLITION WORK IN
THE FIELD.
7. AT ALL WALLS & FLOOR SLABS TO REMAIN, COMPLETELY REMOVE EXIST. CERAMIC TILE
AND SETTING MORTAR, & OTHER FINISHES, DOWN TO MTL. STUDS, CONC. MASONRY OR
CONCRETE, SUITABLE FOR PROPER INSTALLATION OF THE NEW WD. SHEATHING,
BACKING BOARDS, WATERPROOFING SYSTEM, & NEW WALL FINISHES. AT ALL CERAMIC
TILE OR RESINOUS FLOORS, COMPLETELY REMOVE ALL EXIST. TILE OR RESINOUS
FINISHES, GROUT AND MORTAR BEDS, LEAVING THE EXIST. CONCRETE SLAB EXPOSED
AND READY TO RECEIVE THE NEW FINISHES.
5. COMPLETELY REMOVE ALL EXIST. WALL COVERINGS, CHAIR RAIL, & CORNER GUARDS IN
ALL SPACES, UNLESS NOTED OTHERWISE. PATCH, REPAIR & PREPARE WALL SURFACES
AS REQUIRED TO RECEIVE THE SPECIFIED FINISHES.
6. USE EXTREME CARE TO PREVENT DAMAGE TO EXIST. MATERIALS SCHEDULED TO
REMAIN. REPAIR OR REPLACE ALL DAMAGED EXIST. MATERIALS.
7. PROVIDE ALL NECESSARY BRACING & SHORING.
8. REMOVE ALL EXIST. EQUIP. NOT SCHEDULED TO BE REINSTALLED IN THE FINISHED
WORK & DELIVER TO OWNER AT A SPECIFIED LOCATION WITHIN FIVE MILES OF THE
PROJECT SITE. SEE EQUIP. SCHEDULES ON SHEET A3.1 FOR INFORMATION ON ITEMS TO
BE REINSTALLED IN THE FINISHED WORK.
9. REMOVE & STORE ALL EXIST. EQUIP. SCHEDULED TO BE REINSTALLED IN THE FINISHED
WORK. SEE EQUIP. SCHEDULES ON SHEET A3.1 FOR INFORMATION ON ITEMS TO BE
REINSTALLED IN THE FINISHED WORK.
10. OPENINGS TO BE DRILLED OR SAW-CUT INTO EXIST. CONC. SLABS OR WALLS SHALL BE
CAREFULLY SAWN OR CORE-DRILLED TO THE MINIMUM SIZE REQD. FOR THE PROPOSED
CONSTRUCTION. DO NOT EXTEND CUTS PAST OPENING AT CORNERS.
JACK-HAMMERING OF EXIST. CONC. SLABS WILL NOT BE PERMITTED. EXIST. EMBEDDED
REINF. BARS & EMBEDDED ELECT. CONDUITS SHALL BE LOCATED PRIOR TO DRILLING
OR CUTTING, & OPENING LOCATIONS SHALL BE ADJUSTED AS REQD. TO AVOID CUTTING
EXIST. REINF. BARS OR ELECT. CONDUITS, SUBJECT TO THE ADVANCE APPROVAL OF
THE A/E. DO NOT CUT OR DRILL EXIST. BEAMS OR COLUMNS. COORDINATE OPENINGS
WITH SLEEVE SIZES AND WITH APPROVED FIRESTOPPING ASSEMBLIES.
11. EXIST. CONC. MASONRY SHALL BE REMOVED IN FULL SIZE UNITS. WHERE EXIST. CONC.
MASONRY WALLS ARE INDICATED TO BE REMOVED, COMPLETELY REMOVE WALL
CONSTRUCTION FROM TOP OF FLOOR SLAB TO TOP OF WALL, INCL. CONCEALED
ANCHORS, REINFORCING, ELECT. CONDUITS, & OTHER CONCEALED CONSTRUCTION.
PROVIDE WIRING AS REQD. TO MAINTAIN POWER TO ALL EXIST. ELECTRICAL DEVICES
SCHEDULED TO REMAIN - SEE ELECT.
EXIST. WALL TO REMAIN
ITEMS TO BE REMOVED SHOWN
DASHED
MTL. STUD PARTITION TO BE
REMOVED
CFA
HG-1
DHG
HG-2
HG-5
TCW TEMPORARY WALL DURING
CONSTRUCTION
REMOVE EXIST. CERAMIC
TILE WALL FINISH &
CEMENT BD. BACKER
REMOVE EXIST. STAINLESS
STL. WALL PANELS
REMOVE EXIST.
SOUND PANELS
UBO NOTATION:
1/2" = 1'-0"
0 2 53 Lic. No. 016372
EXIST. GLASS-FRONT
BEVERAGE REFRIG. TO
REMAIN (TYP. FOR 4)
REMOVE CMU AS REQD.
FOR PROPOSED DUCT
PENETRATION - SEE MECH.
EXIST. ELECT. PANELBOARD
TO REMAIN
REMOVE EXIST.
DOOR FRAME
REMOVE EXIST.
CASEWORK
REMOVE EXIST.
CASEWORK
REMOVE EXIST.
CASEWORK
REMOVE EXIST. CASEWORK
REMOVE EXIST. CERAMIC
TILE WALL FINISH &
CEMENT BD. BACKER
CAREFULLY COORD. EXTEND OF
VCT DEMOLITION W/ PROPOSED
WALL & FLOORING LOCATIONS (TYP.)
REMOVE EXIST. TILE BASE
EXIST. FLOOR DRAIN - SEE
PLUMB.
REMOVE EXIST.
BUILT-IN SEATING
CMU PARTITION TO BE REMOVED
T C
W T
C W
T C
W T
C W
T C
W T
C W
T C
W T
C W
T C
W T
C W
T C
W T
C W
T C
W
TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW
T C
W T
C W
T C
W T
C W
TCW TCW TCW TCW
REMOVE VCT & CARPET TILE &
PREP FLOOR AS REQD. FOR
ADDITIONAL TILE INSTALLATION -
ADDITIVE BID ITEM NO. 1
EXIST. FLOORING TRANSITION -
CARPET TILE TO VCT
REMOVE EXIST.
CMU PARTITION
TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW TCW
000 ROOM NUMBER
107 115
115B
EXISTING CONDITIONS/DEMOLITION PLAN LEGEND
SCALE: 1/2"=1'-0"
REFLECTED CEILING PLAN - EXISTING CONDITIONS & DEMOLITION
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
D2
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
R E
F
LE
C T
E D
C E
IL
IN
G P
LA
N
E
X
IS
T
IN
G C
O N
D
IT
IO
N
S
D E
M O
LI
T
IO
N
PLAN
NORTH
REMOVE EXIST. GYP. BD.BULKHEAD
EXIST. GYP. BD. BULKHEAD
REMOVE EXIST. WALL-MTD.
LIGHT FIXTURE - SEE ELECT.
BULKHEAD @ ±83" AFF
REMOVE EXIST. SUSP. ACOUST. CLG.
REMOVE EXIST. SUSP. ACOUST.
CLG. AS REQD. FOR PROPOSED
CONST. - PRESERVE & STORE
SUFFICIENT QUANTITIES OF TILE,
TRACK & GRID FOR REINST.
REMOVE EXIST. EX.
HOOD - SEE MECH.
1/2" = 1'-0"
0 2 53
UBO NOTATION:
REMOVE SUSP. BULKHEAD
AS REQD. FOR GREASE DUCT
MODIFICATIONS - SEE MECH.
EXIST. GREASE
DUCT - SEE MECH.
REMOVE EXIST.
WALL-MTD. LIGHT
FIXTURE - SEE ELECT.
Lic. No. 016372
REMOVE EXIST. SUSP. ACOUST. CLG.
MECH. REGISTERS
LAY-IN LIGHT FIXTURES
CAN LIGHT FIXTURE
SMOKE DETECTOR
CLG.-MTD. FIRE ALARM STROBE
WALL-MTD. FIRE ALARM STROBE
WALL-MTD. EMERGENCY LIGHT
WALL-MTD. LIGHT FIXTURE
DEMO RCP LEGEND
ITEMS TO BE REMOVED SHOWN
DASHED
PARTIAL FIRST FLOOR DIMENSIONAL PLAN
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A1
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
P A
R T
IA
L
F
IR
S T
F
LO
O R
D
IM
E N
S
IO
N A
L P
LA
N
, N O
T E
S
PLAN
NORTH
Lic. No. 016372
1/2" = 1'-0"
0 2 53
CFA
HG-1
DHG
HG-2
HG-4
ACCESS.
HAND SINK
EXIST. ELECT.
PANELBOARD
UBO NOTATION:
SERVING
103B5
KITCHEN
115B
KITCHEN
KITCHEN
PASSAGE
103B4
EXIST. GLASS DOOR
DISPLAY REFRIGERATOR
TO REMAIN (TYP. FOR 4)
EXIST. ELECT.
PANELBOARD
3 5/8" 3'-9" 3 5/8" 15'-6"± 3 5/8"
'-7
/2
/8
'-6
/4
/8
'-4
/8
/8
'-1
/2
/8
/8
'-0
/2
/8
4'-0"±
29'-1 1/2"± 3 5/8"
1'-5"± 3 5/8"
TOOTH CMU INTO
EXIST. MASONRY
WALL - SEE STRUCT.
PROVIDE STAINLESS
STEEL HOLLOW MTL.
FRAME IN EXIST.
MASONRY OPENING
3 5/8" 3'-3"
/8
/8
/8
/8
ALIGN MTL. STUD
W/ FACE OF EXIST.
MASONRY
ALIGN MTL. STUD
W/ FACE OF EXIST.
MASONRY
INSTALL CURB FLUSH
W/ OUTER FACE OF
WALL SHEATHING
3 5/8" 1'-5"±3 5/8"
CMU & CONC. LINTEL @
PROPOSED ROUND DUCT
PENETRATION - SEE STRUCT.
INFILL W/ CMU WHERE
DUCTWORK IS
REMOVED - SEE MECH.
'-0
'-0
'-0
'-0
'-0
'-0
'-7
/4
'-4
/2
'-4
/4
8'
-4
/2
'-7
'-9
'-1
/4
/2
ALIGN OUTER FACE OF MTL.
STUD FRAMING W/ EDGE OF
EXIST. FRAMING
'-4
/8
'-4
/8
'-5
'-8
ALIGN OUTER FACE OF MTL.
STUD FRAMING W/ EDGE OF
EXIST. FRAMING
1'-9"
2'-6"
EXIST. CMU WALL
EXIST. WALL
FINISH TO REMAIN
P1
P1 P1
P2
P2
P3
P3
P3
P3
P3
P3
P3 P3
P3
P3
P3
P3
P3
P3
P3
P3
P3 P3
P3
P3
P3
P5
P5
P5P5P5 P5 18"
EXTEND STAINLESS
STL. WALL PANELS
18" PAST EDGE OF
EXHAUST HOOD
EXHAUST HOOD
ABOVE (DASHED)
EXTEND STAINLESS STL.
WALL PANELS 18" PAST
EDGE OF EXHAUST HOOD
8"
P4
P4P4P4
P6
P7
P8
P8
P8
P5
P5
PROPOSED METAL STUD WALL
DIMENSIONAL PLAN LEGEND
EXIST. WALL TO REMAIN
000 ROOM NUMBER - SEE FINISH SCHEDULE
CONC. MASONRY WALL REPAIR
ELECT. PANEL - SEE ELECT.
1. VERIFY ALL EXIST. DIMENSIONS IN THE FIELD & VERIFY THE LAYOUT OF THE MTL. STUD PARTITIONS AS INDICATED ON THE DIMENSIONAL PLANS. REPORT ALL DISCREPANCIES FROM DIMENSIONAL PLANS TO THE A/E, PRIOR TO CONSTRUCTION OF MTL. STUD PARTITIONS. DIMENSIONS NOTED TO BE "CLR." ARE TAKEN FROM
FINISHED SURFACE TO FINISHED SURFACE.
2. PLAN DIMENSIONS INDICATED ARE TAKEN TO ONE OF THE FOLLOWING: (1) THE FACE OF THE EXIST.
CONCRETE MASONRY PARTITIONS, (2) THE FACE OF THE NEW MTL. FRAMING, OR (3) THE FACE OF OUTER LAYER OF WALL SHEATHING. PLAN DIMENSIONS ARE NOT TAKEN TO THE FACE OF THE CERAMIC TILE.
3. METAL STUD FRAMING IS 3 5/8" DEEP, UNLESS OTHERWISE DIMENSIONED ON THE PLANS.
4. SEE WALL TYPE DETAILS ON SHEET A1.1 FOR NUMBERS & TYPES OF WALL SHEATHING LAYERS REQUIRED.
DIMENSIONAL PLAN NOTES:
PROPOSED METAL STUD WALL W/ ACOUSTICAL
BATT INSULATION
WALL SHEATHING TYPE - SEE WALL TYPE DETAILSP#
PT WD. CURB
2'-1 1/2"
A A1A4
B A1A4
C A1A4
D A1A4
E A1A4
F A1A5
G A1A5
H A1A5
K A1A5
J A1A5
L A1A5
M A1A5
N A1A5
103B
M
IN
SIM.
SIM.
A1A6
SIM.
3'-3"
CL
SIM.
02/03/2025
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A7
A1A7
A1A7
A1A7
A1A7
WALL TYPE DETAILS
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A1.1
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
W A
LL
T
Y P
E D
E T
A
IL
S
D O
O R
S C
H E
D U
LE
D E
T A
IL
S
, C O
U N
T E
R T
O P
P
LA
N
Lic. No. 016372
1/2" = 1'-0"
0 2 53
UBO NOTATION:
'-0
2" 3'-0" 2"
STAINLESS STEEL
CASED OPENING FRAME
DOOR TYPES
A
STAINLESS STEEL
DOOR LEAF
B
1. DOOR HARDWARE IS NOT SHOWN ON ELEVATIONS.
DOOR SCHEDULE NOTES:
REMARKSELEV. MAT'LNO. SIZE
102 A
DOOR SCHEDULE
3'-0" x 2'-10" P-LAM / WOOD
NONE -3'-4"± x 7'-4"±
NOTE 1
C/A1/A4
FRAME
CASEWORK
CUSTOM CASED OPENING / STAINLESS STL.
101 B STAINLESS STEEL3'-0" x 7'-0" CASED OPENING / STAINLESS STL.
P1
VCT
5/8" FRT PLYWD.
SUSPENDED CEILING OR
GYP. BD. - SEE SCHED.
EXTEND FRT PLYWD. & CEMENT
BACKERBOARD 6" ABOVE
SUSPENDED CEILING
5/8" CEMENT BACKERBOARD
5/8" CEMENT BACKERBOARD
BELOW PLYWD. - EXTEND 18"
ABOVE FLOOR SLAB
8"
P2
VCT
SUSPENDED CEILING OR
GYP. BD. - SEE SCHED.
EXTEND CEMENT
BACKERBOARD 6" ABOVE
SUSPENDED CEILING
5/8" CEMENT BACKERBOARD
WALL TILE - SEE SCHED.
COVE TILE BASE - SEE SCHED. COVE TILE BASE - SEE SCHED.
WALL TILE - SEE SCHED.
P3
FLOOR TILE - SEE SCHED.
5/8" FRT PLYWD.
SUSPENDED CEILING OR
GYP. BD. - SEE SCHED.
EXTEND FRT PLYWD. & FRP 6"
ABOVE SUSPENDED CEILING
5/8" CEMENT BACKERBOARD
BELOW PLYWD. - EXTEND 18"
ABOVE FLOOR SLAB
8"
FRP - SEE SCHED.
COVE TILE BASE - SEE SCHED.
EXTEND WATERPROOFING
MEMBRANE UP WALL 12" MIN.
CONT. WATERPROOFING MEMBRANE
EXTEND FRP 1" BEHIND COVE BASE
P4
EXIST. FLOOR TILE
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
5/8" FRT PLYWD.
FRT PLYWD. & FRP TERMINATE
9'-4" AFF
5/8" CEMENT BACKERBOARD
BELOW PLYWD. - EXTEND 18"
ABOVE FLOOR SLAB
8"
FRP - SEE SCHED.
COVE TILE BASE - SEE SCHED.
EXTEND FRP 1" BEHIND COVE BASE
P5
FLOOR TILE - SEE SCHED.
5/8" CEMENT BACKERBOARD
SUSPENDED CEILING OR
GYP. BD. - SEE SCHED.
EXTEND CEMENT
BACKERBOARD 24" ABOVE
SUSPENDED CEILING
'-6
4"
STAINLESS STL. WALL
PANELS
COVE TILE BASE - SEE SCHED.
EXTEND WATERPROOFING
MEMBRANE UP WALL 12" MIN.
CONT. WATERPROOFING MEMBRANE
PROVIDE CONT. TRIM @
INTERSECTION OF
STAINLESS STL. PANELS
W/ CEILING
PROVIDE CONT. TRIM @
TOP OF PLYWD. & FRT
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
P6
GYP. BD. CEILING - SEE SCHED.
5/8" CEMENT BACKERBOARD
WALL TILE - SEE SCHED.
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
FLOOR TILE - SEE SCHED.
COVE TILE BASE - SEE SCHED.
EXTEND WATERPROOFING
MEMBRANE UP WALL 12" MIN.
CONT. WATERPROOFING MEMBRANE
P7
GYP. BD. CEILING - SEE SCHED.
5/8" CEMENT BACKERBOARD
WALL TILE - SEE SCHED.
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
FLOOR TILE - SEE SCHED.
COVE TILE BASE - SEE SCHED.
EXTEND WATERPROOFING
MEMBRANE UP WALL 12" MIN.
CONT. WATERPROOFING MEMBRANE1
8"
5/8" FRT PLYWD.
5/8" CEMENT BACKERBOARD
BELOW PLYWD. - EXTEND 18"
ABOVE FLOOR SLAB
P8
GYP. BD. CEILING - SEE SCHED.
(2) LAYERS 5/8" CEMENT
BACKERBOARD
WALL TILE - SEE SCHED.
SEE FLOOR PLAN FOR ADDITIONAL
MASONRY & WALL FRAMING
LOCATIONS & REQUIREMENTS
FLOOR TILE - SEE SCHED.
COVE TILE BASE - SEE SCHED.
EXTEND WATERPROOFING
MEMBRANE UP WALL 12" MIN.
CONT. WATERPROOFING MEMBRANE1
8"
5/8" FRT PLYWD.
5/8" CEMENT BACKERBOARD
BELOW PLYWD. - EXTEND 18"
ABOVE FLOOR SLAB
'-4
2" 3'-4"± 2"
A
DOUBLE ACTING HINGES - ELIASON EASY SWING; PULL HANDLES - HAGER, 3E X 32D
DOUBLE ACTING HINGES - BOMMER IND. INC., #7314, SATIN CHROME FINISH
02/03/2025
2'-10"
'-1
0"
'-0
0' -5
2'-6"
3'-0"
2'-6"
'-5
/4
'-1 1"
'-8
/4
'-4
5'-0"
SCALE: 1/2"=1'-0"
COUNTERTOP PLANPLAN
NORTH
1. ALL DIMENSIONS ARE APPRXIMATE. FIELD VERIFY ALL DETAILS & DIMENSIONS W/ ACTUAL
CASEWORK & EQUIPMENT PROVIDED.
2. PROVIDE SIDE & BACKSPLASHES WHERE INDICATED.
3. PROVIDE SEALANTS @ ALL INTERFACES BETWEEN COUNTERTOPS & BUILT-IN
COMPONENTS & ADJACENT CASEWORK & WALL SURFACES.
COUNTERTOP PLAN NOTES
SOLID SURFACE
COUNTERTOP
SOLID SURFACE
COUNTERTOP
INTEGRAL SOLID
SURFACE
SIDE/BACKSPLASH
8" DIAM. CUT-OUT FOR
UNDER-COUNTER TRASH
CAN - W/ STAINLESS STL.
ESCUTCHEON TRIM RING
UNDERMOUNT HAND SINK &
FAUCET - COORD. SIZE &
LOCATION OF CUTOUTS W/
ACTUAL FIXTURES PROVIDED
CUTOUT FOR BEVERAGE
DISPENSER - COORD.
SIZE & LOCATION W/
ACTUAL EQUIPMENT
PROVIDED
#980 MTL. HALF
WALL
INTEGRAL SOLID
SURFACE
SIDE/BACKSPLASH
SOLID SURFACE
COUNTERTOP
STAINLESS STL.
COUNTERTOP
'-5
INTEGRAL STAINLESS
STL. SIDE/BACKSPLASH
2" DIAM. HOLE W/
STAINLESS STL.
GROMMET
2" DIAM. HOLE W/
STAINLESS STL.
GROMMET
CUT-OUT FOR FRY
PACKAGING CHUTE
CUSTOM STAINLESS
STEEL CASED
OPENING FRAME
OVERLAP EXIST.
MASONRY TO MAXIMIZE
CLR. OPENING SIZE
PARTIAL FIRST FLOOR FINISH PLAN
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A2
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
P A
R T
IA
L
F
IR
S T
F
LO
O R
F
IN
IS
H
E S
P
LA
N , N
O T
E S
PLAN
NORTH
Lic. No. 016372
1/2" = 1'-0"
0 2 53
CFA
HG-1
DHG
HG-2
HG-4
ACCESS.
HAND SINK
EXIST. ELECT.
PANELBOARD
UBO NOTATION:
SERVING
103B5
KITCHEN
115B
KITCHEN
KITCHEN
PASSAGE
103B4
EXIST. GLASS DOOR
DISPLAY REFRIGERATOR
TO REMAIN (TYP. FOR 4)
EXIST. ELECT.
PANELBOARD
EXIST. CMU WALL
EXIST. WALL
FINISH TO REMAIN
EXTEND STAINLESS
STL. WALL PANELS
18" PAST EDGE OF
EXHAUST HOOD
EXHAUST HOOD
ABOVE (DASHED)
EXTEND STAINLESS STL.
WALL PANELS 18" PAST
EDGE OF EXHAUST HOOD
1. ALL TRANSITIONS BETWEEN DISSIMILAR FLOOR MATERIALS ARE TO BE FLUSH & LEVEL.
2. WHERE BASE TILE IS UNDER CASEWORK OR HAS TILE INSTALLED ABOVE, REMOVE BULLNOSE SUCH THAT TOP
OF CUT TILE CAN BE INSTALLED AT 5 1/2" ABOVE FINISHED CONCRETE SLAB.
3. COMPLETELY COVER WALL SURFACES BEHIND CASEWORK WITH SCHEDULE WALL TILE.
4. SEE FINISH & SEALANT SCHEDULES ON SHEET A2.2.
FINISH PLAN NOTES:
PT WD. CURB
A A1A4
B A1A4
C A1A4
D A1A4
E A1A4
F A1A5
G A1A5
H A1A5
K A1A5
J A1A5
L A1A5
M A1A5
N A1A5
N A1A5
103B
A
B
C
D
E
FRP-1 WALL FINISH W/ KT-5B BASE
S-1 WALL FINISH W/ KT-5B BASE
CT-57A WALL FINISH W/ CT-71B BASE
CT-71B BASE AT WOOD CURB
PT-31B PAINT FINISH W/ KT-5B BASE
WALL FINISH LEGEND
B B
B B
B B B B B B B B B B B B B B B B A A A A A A A
A A
AAAAAAAAAAAAA
A A
A A
A A
A A
A A
A
AAAAAAA
A A
A
A
A
A A
A
A A A A A A A A A A A
A A
A A
A
A
A
A A A A A A A A A A A
A
A A
A
AAA
C C C C C C C
F F
F F
F F
F F
F F
F F
F
CCC
C C
C C
C C
C C C C C C C C C C C C C C C C C C
C C
C C
C C
C C C C C C
D D
D D
D D
D D
D D
D D
D D
D
D D
D D
D D
D D
D D
D D
D D
D
D D
D
D D
D
D
E E E E E E
E E
E E
E E
SIM.
SIM.
F CT-45 WALL FINISH W/ CT-71B BASE
SIM.
02/03/2025
ADDITIVE BID ITEM NO. 1 -
ADDITIONAL AREA OF
FLOOR TILE CT-71 (DASHED)
12'-4"±
4'
-1 1"
5'-11"±
'-5
CT-71
KT-5
PARTIAL FIRST FLOOR REFLECTED CEILING PLAN
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A2.1
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
P A
R T
IA
L
F
IR
S T
F
LO
O R
R E
F
LE
C T
E D
C E
IL
IN
G P
LA
N
PLAN
NORTH
Lic. No. 016372
1/2" = 1'-0"
0 2 53
260-R
269-R
211B
211B
UBO NOTATION:
SERVING
103B5
KITCHEN
115B
KITCHEN
KITCHEN
PASSAGE
103B4
FAS
SD
FAS
ACOUST. CLG. @
12'-0"± AFF
FAS
REMOVE & REINSTALL SUSP.
BULKHEAD AS REQD. FOR
GREASE DUCT MODIFICATIONS -
SEE MECH.
GYP. BD. CLG. @ 9'-1"±
AFF - COORD. HEIGHT
W/ EXIST. BULKHEADS
POWER DROP -
SEE ELECT.
REINST. EXIST. ACOUST. CLG.
AGAINST PROPOSED WALL
EXIST. GYP. BD.
BULKHEAD. @ 9'-1"± AFF
STAINLESS STEEL CAP
(CG-3B) ACROSS TOP OF
OPENING
A1A6
SIM.
02/03/2025
ALIGN FINISHED FACE OF
BULKHEAD W/ EXIST.
COLUMN FINISH
MATCH HEIGHT & PROFILE OF
EXIST. GYP. BD. BULKHEAD
REPAIR SUSP. CLG. AS REQD.
FOR GREASE DUCT
MODIFICATIONS - SEE MECH.
STAINLESS STEEL CAP
(CG-3B) ACROSS TOP
OF OPENING
ALIGN FINISHED FACE OF
PROPOSED BULKHEAD W/ EXIST.
BULKHEAD FINISH
1. PROVIDE METAL ACCESS DOORS WHERE INDICATED ON THE DRAWINGS & WHEREVER REQD. FOR ACCESS TO
CONCEALED JUNCTION BOXES, VALVES & ALL EQUIPMENT REQUIRING MAINTENANCE
2. HEIGHTS SHOWN AT CEILINGS ARE TO BOTTOM OF FINISH.
3. SEE FINISH & SEALANT SCHEDULES ON SHEET A2.2.
4. CENTER ALL COMPONENTS THAT ARE LESS THAN 24" X 24" IN A CEILING TILE.
5. DO NOT CUT OR DRILL EXISTING BEAMS, COLUMNS, TRUSSES, HEADERS, OR OTHER STRUCTURAL MEMBERS.
6. ELECTRICAL & MECHANICAL DEVICES ARE SHOWN FOR COORDINATION PURPOSES ONLY. SEE ELECTRICAL &
MECHANICAL DRAWINGS FOR ADDITIONAL WORK REQUIRED FOR ELECTRICAL & MECHANICAL COMPONENTS.
REFLECTED CEILING PLAN NOTES:
ACT-1
PT-31A
OS
OS
OS
FASSD
SD SDOS
OS
OS
Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A2.2
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
F
IN
IS
H
S C
H E
D U
LE
S
Lic. No. 016372
1/2" = 1'-0"
0 2 53
UBO NOTATION:
FINISH MATERIAL SCHEDULE
MARK NOTES
PT-31B
FRP-1
S-1
CT-57A
DESCRIPTION
PROVIDE WALL PANELS, ADHESIVE, MATCHING EDGE & INSIDE CORNER TRIMS, &
OTHER ACCESSORIES AS REQD. PROVIDE MARLITE CORNER GUARDS @ ALL
OUTSIDE CORNERS IN KITCHEN 115 & 115B UNLESS NOTED OTHERWISE.
PROVIDE WALL PANELS, ADHESIVE, MATCHING EDGE & INSIDE & OUTSIDE
CORNER TRIMS, & OTHER ACCESSORIES AS REQD.
FURN. BY INST. BY
GC GC
GC GC
GC GC
GC GC
JOINT WIDTH: 1/8 INCH. GROUT: MAPEI, KERACOLOR U W/ GROUT MAXIMIZER
LATEX ADDITIVE, UNSANDED, 09/GRAY.
CG-3A WALL CORNERS: EXTEND FROM TOP OF FLOOR TO 8'-0" ABOVE ADJACENT
BASE.
CASED OPENINGS: EXTEND FROM TOP OF FLOOR TO HEAD OF OPENING.
GCCUSTOM STAINLESS STEEL CORNER GUARD, 2" X 2" LEGS GC
KT-5
CT-71B
KT-5B
ACT-1 GCCERTAINTEED, PERFORMA / VINYLROCK, #142-CRF-1,
WHITE, 24" X 24"
GC
WALL FINISHES
TRIM
FLOOR & BASE TILE
CEILING FINISHES
PT-31A GCPRIMARY CEILING PAINT, SHERWIN WILLIAMS, PRO MAR
200 ZERO VOC PAINT, SW-7011, NATURAL CHOICE
GC
GRID: STANDARD 15/16", SQUARE LAY-IN, WHITE.
QUARRY TILE, CREATIVE MATERIALS CORPORATION,
GRAY 507, 8" X 8"
GCGC
GCGC
GCGC
INSTALL W/ THINSET MORTAR. JOINT WIDTH: 3/8 INCH. GROUT: MAPEI,
KERAPOXY IEG CQ, 47/CHARCOAL.
CT-71 PORCELAIN TILE, CREATIVE MATERIALS CORPORATION,
LAVA, LIGHT GREY,12" X 12"
GCGC INSTALL ON 45 DEGREE ANGLE. JOINT WIDTH: 3/16 INCH. GROUT: MAPEI,
ULTRACOLOR, 47/CHARCOAL.
CEILING
FINISH SCHEDULE
FLOOR BASE WALLS REMARKS
SPACE NAME &
NO.
CEILING
HEIGHT
-DINING 103 EXIST.EXIST. EXIST. -
-VENDING 103B ACOUST.EXIST. VCT TILETILE 12'-0"±
-PASSAGE 103B4 EX. ACOUST.EXIST. EXIST.EXIST. -
1. PROVIDE VCT, BASE, SUSPENDED ACOUSTICAL CEILINGS & PAINT TO MATCH EXISTING AT
ALL WALL & CEILING LOCATIONS ADJACENT TO THE RENOVATED AREA.
FINISH SCHEDULE NOTES:
MATCH HEIGHT OF EXIST. DINING AREA BULKHEADSSERVING 103B5 GYP. BD.TILE TILETILE 9'-1"±
-KITCHEN 107 ACOUST.EXIST. EXIST.EXIST. -
-KITCHEN 115 EXIST.EXIST. TILE -
-KITCHEN 115B ACOUST.TILE FRPTILE 9'-6"
EXIST.
TILE
EXIST.
FRP
FRP
TILE
EXIST.
EXIST.
ST. STL/FRP
GYP. BD.
TILE
EXIST.
TILE
EXIST,
ST. STL/FRP
NORTH EAST SOUTH WEST
EXIST. EXIST. EXIST.
FRP - MARLITE, STANDARD FRP, P-199, BRIGHT WHITE,
.090" THICK X 4 X 10 PANELS
STAINLESS STEEL WALL PANELS, 18 GAUGE, GRADE 430
SUBWAY WALL TILE, DALTILE, BISCUIT, 4 1/4" X 8 1/2"
PRIMARY WALL PAINT, SHERWIN WILLIAMS, PRO MAR
200 ZERO VOC PAINT, SW-7011, NATURAL CHOICE,
PORCELAIN TILE COVE BASE, CREATIVE MATERIALS
CORPORATION, LAVA, LIGHT GREY,6" X 12"
QUARRY TILE COVE BASE, CREATIVE MATERIALS
CORPORATION, GRAY 507, 6" X 8" COVE
REMOVE BULLNOSE WHEN BASE IS UNDER MILLWORK OR BELOW WALL
TILE. JOINT WIDTH: 3/16 INCH. GROUT: MAPEI, ULTRACOLOR, 47/CHARCOAL.
INSTALL W/ THINSET MORTAR. JOINT WIDTH: 3/8 INCH. GROUT: MAPEI,
KERAPOXY IEG CQ, 47/CHARCOAL.
FINISH: FLAT.
FINISH: EGGSHELL.
CG-3B WALL CORNERS: EXTEND FROM TOP OF FLOOR TO 8'-0" ABOVE ADJACENT
BASE.
CASED OPENINGS: EXTEND FROM TOP OF FLOOR TO HEAD OF OPENING.
GCCUSTOM STAINLESS STEEL WALL END CAP, WALL CAP
PLUS 2" LEG @ ADJACENT WALL FACES
GC
MT-1 OWNERMILLWORK FACE PANELS, CFX PRODUCTS, TRI SMOKE,
T1-7060
OWNER
SS-13 OWNERSOLID SURFACE, AVONITE, FOUNDATIONS MATERIALS
COLLECTION, F1-9865, ARTICA
OWNER
MILLWORK
S-2 STAINLESS STEEL COUNTER 16 GAUGE STAINLESS STEEL OVER (2) LAYERS PLYWD., BRUSHED #4 FINISH, ROUGHNESS OF RA 25 MICRO IN. OR LESS.
PL-40 PLASTIC LAMINATE, WILSONART, SHADOW -
PL-51 PLASTIC LAMINATE, NEVAMAR, RAVEN -
OWNEROWNER
OWNEROWNER
OWNEROWNER
CT-45 GC GC GROUT: MAPEI, KERACOLOR U W/ GROUT MAXIMIZER LATEX ADDITIVE,
UNSANDED, 09/GRAY.
STAINLESS STEEL WALL TILE, CREATIVE MATERIALS
GROUP, VOGUE STAINLESS STEEL, 1"X2" BRICK, 12X12
SHEET
02/03/2025
SEALANT COLOR
SEALANT SCHEDULE
TO MATERIAL
FRONT CASEWORK (PL-1) STILES & RAILS COLOR RITE FIL-STICK BB08
SUBWAY WALL TILE MATCH BASE TILE GROUTBASE TILE
SUBWAY WALL TILE MATCH WALL TILE GROUTWALL TILE (INSIDE CORNERS)
WHITE - BONECOUNTER TOPS / CABINETS (VERTICAL)
STAINLESS STEELSTAINLESS STEEL
WHITE
FRONT CASEWORK PANELS (PL-1)
CEILING GRID
MATERIAL
SUBWAY WALL TILE
SUBWAY WALL TILE
SUBWAY WALL TILE
WHITE - BONEADJACENT MATERIALSOLID SURFACE COUNTER TOP
STAINLESS STEELALL MATERIALSSTAINLESS STEEL CORNER / CAPS
WHITEBASE TILEFRP
WHITEPAINTED DOOR FRAMES
WHITECEILING GRID
CLEARSTAINLESS STEEL FRAMES / SPLASHES / HAND SINKS
CLEARESCUTCHEONS
WHITECEILING GRIDSUBWAY WALL TILE
STAINLESS STEELSTAINLESS STEEL WALL PANELSHOODS / SHROUDS
MATCH BASE TILEUNDERSIDE OF CABINETSBASE TILE
FRP
FRP
FRP
FRP
PARTIAL FIRST FLOOR KITCHEN EQUIPMENT PLAN
Blacksburg, Alliance Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A3
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
K
IT
C H
E N
E Q
U
IP
M E
N T
P
LA
N
PLAN
NORTH
Lic. No. 016372
1/2" = 1'-0"
0 2 53
CFA
HG-1
DHG
HG-2
HG-4
200S-R
200S-R
200U-R
187A
182L
310-R
315W
102C
202A
355F
703L
703M
703S
187C
182L
182L
187D
703S
703M
703L
308E
187B
420-R
300A
301C 182L
300B
300DL
300F
300X
300C 500A-R
122A
182L
120A
187F
438L
564A
420L-R
562A-R
580H
105D
563DL
563Da
105A
560A
187E
522L-R
260-R
522L-R
269-R
562AT-R
1242S
580HT
122B
1242AS
121B
564AT
187G
503B 503T
422A 1114 1244S 443GLT
505VLT
505VLT
505VA
266 524-R 523-R 523-R 523-R 523-R581-R 270
1336 1336 1336
444D 444D-R 444SL-R
1374 431
1384 570
1141G
600A
1330 1332
305-R
620L
211B
211B
1141F
1382 1372F
440C 202A
1382 1372F
440C
442WC
359L
360F
ACCESS.
HAND SINK
360F
359L
1141F
631M
1371F
EXIST. ELECT.
PANELBOARD TO
REMAIN
UBO NOTATION:
SERVING
103B5
KITCHEN
115B
KITCHEN
KITCHEN
PASSAGE
103B4
EXIST. GLASS DOOR
DISPLAY REFRIGERATOR
TO REMAIN (TYP. FOR 4)
EXIST. ELECT.
PANELBOARD TO
REMAIN
1. SEE KITCHEN EQUIPMENT SCHEDULE ON SHEET A3.1.
KITCHEN EQUIPMENT PLAN NOTES:
400L
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A6
A1A7
A1A7
A1A7
A1A7
A1A7
171A
952-R
950-R
02/03/2025
ABOVE
ABOVE
Architects
Virginia
DATE:
PROJECT NO:
Inc.
The
CHECKED BY:
DRAWN BY:
DESIGNED BY:
A3.1
96554
2/03/25
SLL
SLL
DAR / SLL
C H
IC
K
−F
IL
−A R
E N
O V
A T
IO
N
S O
W E
N S
H A
L L
V irg in ia
T e ch
B la ck sb u rg
, V irg in ia
E Q
U
IP
M E
N T
S C
H E
D U
LE
S
Lic. No. 016372
1/2" = 1'-0"
0 2 53
UBO NOTATION:
101 1 SERVING COUNTER MILLWORK PROVIDER 101 REFER TO MANUFACTURER SHOP DRAWINGS
106 1 DESSERT COUNTER MILLWORK PROVIDER 106 REFER TO MANUFACTURER SHOP DRAWINGS
110 1 BACK SERVING COUNTER MILLWORK PROVIDER 110 REFER TO MANUFACTURER SHOP DRAWINGS
120 1 PRIMARY BOARDS COUNTER MILLWORK PROVIDER 120 REFER TO MANUFACTURER SHOP DRAWINGS
EQUIPMENT SCHEDULE
102c 1 MODULAR BEVERAGE CADDY KIT 3 MILLWORK PROVIDER 102c KIT INCLUDES (1) BACKPLATE, (4) LID HOLDERS, AND (1) STRAW HOLDER - (1) DRINK CARRIER TO BE PROVIDED PER RESTAURANT (NOT SHOWN ON DRAWINGS)
105 1 SERVING COUNTER FCC MODEL TBD 105 REFER TO MANUFACTURER SHOP DRAWINGS
105a 1 STAINLESS STEEL BIN HOLDER MILLWORK PROVIDER 105a 105d 1 PACKAGE BAG HOLDER MILLWORK PROVIDER 105d
111 1 STAINLESS STEEL UNDER COUNTER MOUNT HAND SINK VOLLRATH 10101-1 111
120a 1 BUILT-IN BREAD RACK SLIDES MILLWORK PROVIDER 120a INCLUDE 2 BRACKETS PER SET - REFER TO MANUFACTURER SHOP DRAWINGS
121B 1 COUNTER TOP HOT ROUND PACKAGING HOLDER FRANKE 121B
EQUIPMENT SCHEDULE (FUTURE ITEMS)
F444S 1 FUTURE SINGLE THAWING CABINET (32") TRAULSEN RET132EWUT-FHS F444S
F503T 1 FUTURE EGG STATION ANTUNES ES-600R 9300657 F503T
F523 1 FUTURE PRESSURE FRYER HENNY PENNY PFE-500 F523
GRUB HUB MASTER EQUIPMENT SCHEDULE
ITEM NO. Q
U
A N
T
IT
Y
DESCRIPTION OF EQUIPMENT
187A 1 GRUB HUB BEVERAGE KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187a 6 GRUB HUB WALL MOUNT KDS ARM USED TO MOUNT ORDER MONITORS - ORDER MODEL #GH7000-1000 W/ WALL FLEXMOUNT & KC3 BRACKET - NOT SHOWN ON DRAWINGS 187B 1 GRUB HUB DESSERT KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187C 1 GRUB HUB EXPO 1 KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C)
187D 1 GRUB HUB EXPO 2 KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187E 1 GRUB HUB FRY KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187F 1 GRUB HUB PRIMARY BOARDS KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C) 187G 1 GRUB HUB SECONDARY BOARDS KDS MONITOR INCLUDES CHROMEBOX (#GRC-0000029), KEYBOARD (#GRC-0000070), & BUMP BAR (#GRC-0000030C)
188 1 GRUB HUB POS KIOSK REFER TO MANUFACTURER SHOP DRAWINGS
ITEM NO. DESCRIPTION OF EQUIPMENT APPROVED MANUFACTURER MODEL ITEM NO. REMARKSQ
U
A N
T
IT
Y
ITEM NO. DESCRIPTION OF EQUIPMENT APPROVED MANUFACTURER MODEL ITEM NO. REMARKSQ
U
A N
T
IT
Y
103 4 CUP DISPENSER SAN JAMAR 103C2410CCFA3
563Da 1 DOUBLE TIER SANDWICH SLIDE STAND MILLWORK PROVIDER 563Da REFER TO MANUFACTURER SHOP DRAWINGS
27807097
122A 1 PACKAGING STORAGE SYSTEM FRANKE 122A27801283
122B 1 XL MENU TAB PACKAGING HOLDER FRANKE 122B27807100
300a 1 MILKSHAKE BASE DISPENSER KANPAK 300aCDE211 300b 1 MILKSHAKE BASE DISPENSER SHELF ALL SOUTHERN FABRICATORS 300b 300c 2 SINGLE-SPINDLE MIXER HAMILTON BEACH 300cHMD300M-CFA 300dL 1 TOPPING DISPENSER / HOLDER ALL SOUTHERN FABRICATORS 300dL7201-NCH 300f 1 DOUBLE SLIMLINE COOKIE DISPENSER SERVER 300f88847
300X 1 DOUBLE BARREL ICE CREAM MACHINE TAYLOR 300X079333BWDC (AIR COOLED)
301C 1 CUP DISPENSER AND LID ORGANIZER WIREWORKS 301CC8504WF
360 2 HAND SINK EAGLE 360YCFA-HSAN-0004-00
400L 1 SINGLE UPRIGHT FREEZER (30") TRAULSEN 400LRLT132WUT-FHS
421 1 DOUBLE UNDERCOUNTER REFRIGERATOR (48") TRAULSEN 421UHT48-LR
422AT 1 REFRIGERATED EQUIPMENT STAND (36") TRAULSEN 422ATTE036HT-ZCF01
431 1 DOUBLE WORKTOP REFRIGERATOR (48") TRAULSEN 431UHT48-ZCF-LR
438L 1 COLD RAIL (33") RANDELL 438LCR9039M-CFA
440C 2 ICE BATH BREADING TABLE DUKE 440CBSTA-120-US
442WC 1 SINGLE UPRIGHT REFRIGERATOR (30") TRAULSEN 442WCRH132W-ZCF16
443GLT 1 SINGLE UPRIGHT REFRIGERATOR (24") TRAULSEN 443GLTRHT132DUT-HHG
444D 1 DOUBLE THAWING CABINET (52 1/8") TRAULSEN 444DRE232N-ZCF02
503b 1 EGG TABLE (48") ATLANTA CUSTOM FABRICATORS 503bCFA-ET-503
503T 1 EGG STATION ANTUNES 503TES-600R-9300657
505va 1 VECTOR OVEN STAND ALTO-SHAAM 505Va5034382-0
505VLT 2 VECTOR OVEN ALTO-SHAAM 505VLTVMC-H3H-106226
560 1 FRY HOLDING STATION BKI 560FW-15BB312007F (FW15-00000018)
560a 1 FRY CARTON DISPENSER ASSEMBLY SAN JAMAR 560aWFD210 & WFD230
563DL 1 DOUBLE TIER SANDWICH SLIDE (38") BKI 563DL2TSM-3824L
564A 1 VISUAL HOT HOLDING CABINET (2X2) MERCO 564AMHC22SNT1T
564AT 1 VISUAL HOT HOLDING CABINET (2X2) MERCO 564ATMHC22SNT1T
570 1 COOLING RACK H&K 570CFA104
580H 1 VISUAL HOT HOLDING CABINET (5X2) MERCO 580HMHC52SNT1T
580HT 1
600 1 MIXER HOBART 600HL200-1
600a 1 MIXER TABLE (30"X20") ATLANTA CUSTOM FABRICATORS 600a3ACF498
620L 1 FOOD PREP TABLE (24"X24") EAGLE 620LT2424STE-BS
649 1 MODIFIED DUAL LINE TABLE (72") EAGLE 649YCFA-DL-0040-00
MOUNT ON MILKSHAKE BASE DISPENSER SHELF
LEFT HAND MOUNT - ORDER (1) #3FRA112
WITH SIDE MOUNTING BRACKETS
HINGE LEFT - ORDER WITH FINISHED BACK & 4 5/8" CASTERS
ORDER WITH 4 1/8" CASTERS
ORDER WITH 4" CASTERS
ORDER WITH 6 1/4" CASTERS & BACKSPLASH TOP
COMPRESSOR ON LEFT
LEAF INCLUDED WITH TABLE - INSTALL IF SHOWN ON DRAWINGS
HINGE RIGHT - PROVIDE FINISHED BACK - ORDER WITH 6 1/4" CASTERS
HINGE STANDARD - ORDER WITH 6 1/4" CASTERS
VISUAL HOT HOLDING CABINET (5X2) MERCO 580HTMHC52SNT1T
INCLUDES GASKET FOR STACKING VECTOR OVENS
HINGE LEFT
ORDER MOUNTING RACK AND 4-PIECE CHUTE KIT
CORD EXITS LEFT
ORDER WITH LIDS/TRAY SEALS, AMBER PANS, AND FALSE BOTTOMS
ORDER WITH LIDS/TRAY SEALS, AMBER PANS, AND FALSE BOTTOMS
ORDER WITH LIDS/TRAY SEALS
ORDER WITH LIDS/TRAY SEALS
ORDER WITH (1) #3HOB405, (1) #3HOB061, (2) #3HOB318, (2) #3HOB319, AND (1) #3HOB058
WITH 5" CASTERS
WITH BACKSPLASH AND 1 5/8" DIAMETER LEGS
WITH BREAD RACKS ON RIGHT - NO BRIDGE
660 4
702 8 703L 5
1114 1 1141F 5
1170 1 1242AS 1 CANTILEVERED SHELVING (30"X36" OVERHEAD ADD) 1242AS METROSEAL GRAY - WITH 86" UPRIGHT AND 30"x36" TOP TIER
LOW-PROFILE LEG INTERMETRO 1170SML30-LP REPLACES STANDARD LEG FOR CANTILEVERED SHELVING
METROSEAL GRAY - MOUNT ON 12" CENTERS AT FOOD PREP AREA - NOT SHOWN ON PLAN
VERTICAL SHELF DIVIDER (18"D X 8"H) INTERMETRO 1141FDD18FC FOR SOLID SHELF - MOUNT ON 12" CENTERS AT FOOD PREP AREA - NOT SHOWN ON PLAN CANTILEVERED SHELVING TASK LIGHT BRACKET (48") INTERMETRO 1114DD9528 MOUNT TO UPPER TIER OF SHELVING UNIT FOR TASK LIGHT
LARGE CONDIMENT BIN CARLISLE 703L104976GY
WALL MOUNT SINGLE RAIL ULINE 702H-4681 SUPPORT FOR CONDIMENT BINS
PAPER TOWEL DISPENSER SAN JAMAR 660T1400REBKB RE: ARCHITECTURAL SHEETS FOR DETAILS ON MOUNTING HEIGHTS AND LOCATIONS
703M 5 MEDIUM…
This is the start of the file's text. The full file is on GovTribe.