This document is a comprehensive set of construction documents for the Fox Valley Technical College Veterinary Technician Classroom Remodel project, involving Eppstein Uhen Architects and located in Appleton, Wisconsin. The project consists of a 566 square foot interior renovation to convert multiple first-floor rooms into one larger classroom space. The construction documents are dated 09/16/2025 and include architectural, mechanical, and electrical plans detailing the scope of work, which encompasses general trades, HVAC modifications, electrical updates, flooring replacement, acoustical ceiling installation, casework modifications, and painting. The project will be awarded to a single general contractor and involves renovations at 2809 N Park Drive Lane in Appleton.

The project documents indicate a comprehensive renovation approach with specific technical requirements, including the replacement of an existing heat pump, reconfiguration of mechanical systems, electrical device relocations, and careful attention to ADA accessibility standards. The estimated occupant load for the renovated space is 112.5 persons, with the primary occupancy classified as Business (B). While specific pricing details are not explicitly outlined in the documents, the project appears to be funded through Fox Valley Technical College's capital improvement budget. The documents provide extensive technical specifications, including detailed mechanical schedules, electrical plans, and architectural finish requirements, suggesting a thoroughly planned and carefully scoped renovation project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NUMBER:09/16/2025

FVTC VETERINARY

TECHNICIAN

CLASSROOM REMODEL

925743

CONSTRUCTION DOCUMENTS

IFB 26021

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

ARCHITECTURAL

EPPSTEIN UHEN ARCHITECTS, INC.

1155 Lombardi Avenue, Suite 200 Green Bay, WI 54304

(920) 336-9929 www.eua.com

DIRECT PHONE:

EMAIL ADDRESS:

PROJECT CONTACT:

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

INDEX

G000

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

Matt Van Lanen

(920) 278-0359 mattv@eua.com

EMAIL ADDRESS:

DIRECT PHONE:

PROJECT CONTACT:

MECHANICAL

EPPSTEIN UHEN ARCHITECTS, INC.

1155 Lombardi Avenue, Suite 200 Green Bay, WI 54304

PHONE: (920) 336-9929

www.eua.com

Alex Tessen

(920) 278-0335 alext@eua.com

EMAIL ADDRESS:

DIRECT PHONE:

PROJECT CONTACT:

ELECTRICAL

MSA PROFESSIONAL SERVICES

116 Fremont Street Kiel, WI 53042

PHONE: (920) 894-7800

www.msa-ps.com

Laura Gilbert

(920) 264-0197 lgilbert@msa-ps.com

Map data ©2025 Google

GENERAL

G000 INDEX

G101 1ST FLR LIFE SAFETY PLAN

ARCHITECTURAL DEMOLITION

AD101 1ST FLR DEMOLITION PLAN

ARCHITECTURAL

A020 ADA REQUIREMENTS

A101 1ST FLR PLAN, CLG PLAN, DOOR SCHEDULE

A121 1ST FLR FINISH PLAN AND MATERIAL SCHEDULE

MECHANICAL

M000 GENERAL MECHANICAL INFORMATION

M101 1ST FLR MECHANICAL PLAN

M600 MECHANICAL SCHEDULES & DETAILS

ELECTRICAL

E000 ELECTRICAL SYMBOLS AND ABBREVIATIONS

ED101 1ST FLR DEMOLITION PLAN - ELECTRICAL

E101 1ST FLR PLANS - ELECTRICAL

SHEET INDEXABBREVIATIONS

SYMBOL LEGEND

VICINITY MAP

TRUE

N

PLAN

N

B

000-00

NAME

TYPE

HEIGHT

XXX

XX

FLOOR

BASE

WALL

REMARKS

PARTITION TYPE

DOOR

KEYNOTE

FURNITURE

EQUIPMENT

WINDOW

XX

CEILING

CASEWORK

FINISH PLAN

A

B

A

ELEVATION

DATUM

VIEW NUMBER

VIEW NAME

VIEW SCALE

DEMOLITION

GRID AND GRID IDENTIFICATION

1 2 1 2

A000

A000

SIM

A000

SIM

BUILDING

SECTIONS

OTHER

SECTIONS

CONSTRUCTION PHASES

ELEVATIONS

ROOM

DETAILS

TITLE

1/2" = 1'-0"

DIMENSION REFERENCES

EXISTING NEW

NEWEXISTING

A1

SIM

TAGSCALLOUTS GRAPHICS

NORTH ARROW

TO OBJECT CENTER TO OBJECT FACE

OR OTHER GEOMETRY

EQ EQ EQ 5'-0" 4'-0"

W" x H" x D"

A000

Level 0'-0"

A000-000A

A2

A

A4

A000A

A2

A

A4

A/C air conditioning

A/E Architect/Engineer

ACT acoustical ceiling tile

ADDL additional

ADDM addendum

ADJ adjustable

AFC above finished counter

AFF above finished floor

AFG above finished grade AFS above finished slab

ALT alternate

ALUM aluminum

APPD approved

APT apartment AP acoustical panel

ASC above suspended ceiling

BB baseboard

BLDG building

BLT borrowed lite

BLW below

BPL base plate BO bottom of

BOS bottom of steel

CB catch basin, construction bulletin

CF/CI contractor furnished, contractor installed

CF/OI contractor furnished, owner installed CF/VI contractor furnished, vendor installed

CG corner guard

CIP cast-in-place

CNTR counter CL centerline

CLG ceiling

A

B

C

CLR clear

CM construction management CM construction manager

CMU concrete masonry unit

CO cleanout

COL column

CONC concrete

CORR corridor CPT carpet

CSWK casework

CT ceramic tile

CW cold water

CTB ceramic tile base

DBL double

DEMO demolition

DEPT department

DF drinking fountain DIA diameter

DP decorative panel

DR door

DR FR door frame

DTL detail

DS downspout DW dishwasher

DWG drawing

E east

EIFS exterior insulation & finish system

EL elevation

EJ expansion joint

ELEC electric

ELEC electrical ELEV elevator

EP epoxy

EPS expanded polystyrene board

EQ equal

ETR existing to remain EXIST existing

EXT exterior

F

G

H

F female

F filler

FA fire alarm FA fluid-applied

FAB fabric

FC file cabinet

FD floor drain

FE fire extinguisher

FEC fire extinguisher cabinet

FHC fire hose cabinet

FIN finish

FLR floor

FM factory mutual FM floor mat

FO finished opening

FP fire protection

FP fireproof

FPL fireplace

FRP fiberglass reinforced plastic

FRT fire retardant treated

FTG footing

GA gauge

GALV galvanized

GB grab bar

GC general contractor

GL glass

GLU LAM glue laminated wood

GR grade, grading

GT grout

GYP BD gypsum

HB hose bibb

HC hollow core

HDWE hardware

HM hollow metal

HORIZ horizontal HSKP housekeeping

HGT height

HR hour

HVAC heating, ventilating

& air conditioning HW hot water

HWY highway

T&M time & materials

TEMP temperature

TEMP temporary TER terrazzo

TERB terrazzo base

TFF top of finished floor

TKBD tackboard

TO top of

TOB top of beam TOC top of concrete

TOJ top of joist

TOPO topography

TOS top of slab

TOS top of steel TRNS transom

TYP typical

UNO unless noted otherwise

VERT vertical

VF/CI vendor furnished, contractor installed

VF/OI vendor furnished, owner installed

VF/VI vendor furnished, vendor installed

VNR veneer

VIF verify in field

W west

W/ with

W/O without WC water closet

WC wall covering

WD wood

WDB wood base

WDV wood veneer

WH water heater WP wall protection

WP work point

WT window treatment

XPS extruded polystyrene board

ID inside diameter

INSUL insulation

INT interior

JS janitor sink

LAM laminate LAV lavatory

LF linear foot

LL live load

MAT material MAX maximum

MC modular carpet tile

MECH mechanical

MFR manufacturer

MICRO microwave MIN minimum

MIN minute

MISC miscellaneous

MJ movement joint

MO masonry opening

MS mop sink MTL metal

N north

NA not applicable NIC not in contract

NO number

NM nominal

NS no scale

NTS not to scale

OA overall

OC on center

OD outside diameter

OF/CI owner furnished, contractor installed

OF/OI owner furnished, owner installed

OF/VI owner furnished, vendor installed

OH DR overhead door OPH opposite hand

OPNG opening

PJ panel joint

PLAM plastic laminate

PLYWD plywood PNL panel

PREFAB prefabricated

PREFIN prefinished

PSI pounds per square inch PT paint

PTN partition

QT quarry tile QTB quarry tile base

QTY quantity

QTZ quartz

RB resilient base RCP reflected ceiling plan

RD roof drain

REBAR reinforcing steel bars

REC recess

REF reference REF refrigerator

RF resilient flooring

REV revision

RFS room finish schedule

RO rough opening

S south

SAN sanitary

SC sealed concrete SC solid core

SCHED schedule

SCHED scheduled

SF square foot

SIM sim SL sidelite

SNGL single

SS solid surface

SST stainless steel

ST stain ST stair

STC sound transmission coefficient

STL steel

STN stone STNB stone base

STRUCT structure

C

D

E

I

M

N

J

L

O

Q

R

S

P T

W

X

U

V

PROJECT TEAM

PROJECT LOCATION

DATE DESCRIPTION

09/16/2025 CONSTRUCTION DOCUMENTS

LIFE SAFETY GENERAL NOTES

MEANS OF EGRESS

1. WHEN A WALL HAS MORE THAN ONE CLASSIFICATION, THE MOST RESTRICTIVE REQUIREMENTS FOR EACH CLASSIFICATION SHALL

APPLY.

2. FOR NEW CONSTRUCTION, PERIMETER SMOKE-SEALS MAY BE REQUIRED AT FIRE-RATED DOORS IN CERTAIN OCCUPANCIES.

LIFE SAFETY DRAWING NOTES APPLICABLE TO EXISTING CONDITIONS

EXISTING CONDITIONS INDICATED BY THESE LIFE SAFETY PLANS ARE BASED ON INFORMATION PROVIDED AND AN ANALYSIS OF APPLICABLE CODES. IF EXISTING FIELD CONDITIONS ARE DISCOVERED TO BE DIFFERENT FROM WHAT IS INDICATED ON THESE PLANS, CONTACT THE

ARCHITECT.

WITHIN LIMITS OF NEW CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FOLLOWING AND PATCH

DEFICIENCIES (IF ANY ARE DISCOVERED) OF EXISTING ASSEMBLIES.

• CONTINUITY OF SPRAYED ON FIRE PROTECTION

• CONTINUITY OF FIRE RATINGS AND SMOKE RESISTIVE REQUIREMENTS OF FLOOR ASSEMBLIES

• WALL FIRE RATINGS AND SMOKE RESISTIVE REQUIREMENTS AS INDICATED BY THESE LIFE SAFETY PLANS

• FIRESTOPPING OF THROUGH PENETRATIONS

• FIRESTOPPING OF PERIMETER JOINTS

BUSINESS (B)

11,253 SF

LEVEL 2

ALTERATION

566 SF

34"

34"

112'-11"

TD = 300'

OCCUPANCY LEGEND

BUSINESS (B)

F.E.C.

F.E.C.

F.E.C.

EXIT LOAD BY CALCULATION

EXIT WIDTH REQUIRED

EXIT WIDTH PROVIDED

EXIT LOAD CAPACITY

HORIZONTAL 2-WAY

X" = CLEAR WIDTH OF OPENING IN INCHES

### = OCCUPANT LOAD

HORIZONTAL 1-WAY

X" = CLEAR WIDTH OF OPENING IN INCHES

### = OCCUPANT LOAD

EXIT DISCHARGE

X" = CLEAR WIDTH OF OPENING IN INCHES

### = OCCUPANT LOAD

FROM ROOM OR LEVEL

X" = CLEAR WIDTH OF OPENING IN INCHES

### = OCCUPANT LOAD

X"###

X"###

HE

X"###

HE

X"######X"

AR

AREA OF RESCUE

ASSISTANCE

EXIT PASSAGEWAY

EXIT PASSAGEWAY (SUITE)

EXIT ACCESS

EXIT DISTANCE

X'-X"

VERTICAL EXIT

STAIRWAY

(NON-REQUIRED

MEANS OF EGRESS)

SUITE DESIGNATIONS

HORIZONTAL

RATED ASSEMBLY

HAZARDOUS AREAS

TD = XX'

TRAVEL LENGTH

MAXIMUM TRAVEL DISTANCE

X OCC

XX"

XX"

X OCC

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR LIFE

SAFETY PLAN

G101

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

DESIGN INTENT IS TO MAINTAIN EXISTING QUANTITIES OF PLUMBING FIXTURES. OCCUPANT LOAD OF ANY GIVEN STORY IS NOT BEING INCREASED BY

MORE THAN 20%

MINIMUM PLUMBING FIXTURE REQUIREMENTS CHAPTER 29 SECTION 2902.1

50 FT MAXIMUM

DEAD-END CORRIDOR CHAPTER 10 SECTION 1020.4

100 FT MAXIMUM

COMMON PATH OF TRAVEL CHAPTER 10 SECTION 1006.2.1

300 FT MAXIMUM

EXIT TRAVEL DISTANCE CHAPTER 10 SECTION 1017.2

SEE SEPARATE SCHEDULE(S) FOR CALCULATIONS

OCCUPANT LOAD CHAPTER 10 SECTION 1004

ROOF CONSTRUCTION & SECONDARY

MEMBERS

0 HOUR 0 HOUR

FLOOR CONSTRUCTION & SECONDARY

MEMBERS

0 HOUR 0 HOUR

BEARING WALLS - INTERIOR 0 HOUR 0 HOUR

BEARING WALLS - EXTERIOR 0 HOUR 0 HOUR

PRIMARY STRUCTURAL FRAME 0 HOUR 0 HOUR

REQUIRED PROVIDED

SEE LIFE SAFETY DRAWINGS FOR ADDITIONAL ELEMENTS

REQUIRING FIRE RESISTIVE RATINGS

FIRE RESISTIVE RATINGS CHAPTER 6 SECTION 601

NFPA STANDARD USED 13 CHAPTER 9 SECTION 903.3.1

MONITORING TYPE CENTRAL STATION CHAPTER 9 SECTION 903.4

FIRE SUPPRESSION COMPLETE CHAPTER 9 SECTION 903.2

FIRE ALARM COMPLETE CHAPTER 9 SECTION 907.2

FIRE PROTECTION

FIRST FLOOR 566 SF LEVEL 2

LOWER LEVEL 0 SF

WORK AREA ALTERATION LEVEL

WORK AREA

S-1 (STORAGE)

A-3 (ASSEMBLY)

ACCESSORY OCCUPANCIES CHAPTER 5 SECTION 508.2

B (BUSINESS)

PRIMARY OCCUPANCY CHAPTER 3 SECTION 302

INTERIOR ALTERATION

PROJECT TYPE

TOTAL BUILDING AREA 29,257 SF

NUMBER OF STORIES 2 INCLUDES STORIES ABOVE AND BELOW GRADE

CONSTRUCTION CLASSIFICATION TYPE VB

GENERAL BUILDING INFORMATION

2009 ICC ANSI A117.1 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

2015 INTERNATIONAL BUILDING CODE (IBC) AS MODIFIED BY WISCONSIN CHAPTERS SPS 361 AND 362

2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) AS MODIFIED BY WISCONSIN CHAPTERS SPS 361 AND 366

APPLICABLE BUILDING CODES

FIRE DEPARTMENT: FIRE CHIEF JEREMY HANSEN, 700 N DREW STREET, APPLETON, WI 54911 (920) 832-5810

ZONING: PLANNING DIRECTOR KARA HOMAN, 100 N. APPLETON STREET, APPLETON, WI 54911 (920) 832-6408

BUILDING REVIEW AGENCY: STATE

APPLICABLE JURISDICTION(S)

STATE: WISCONSIN

COUNTY: OUTAGAMIE

MUNICIPALITY: APPLETON

LOCATION

FOX VALLEY TECHNICAL COLLEGE

OWNER

THE PROJECT CONSISTS OF 566 SF OF INTERIOR RENOVATION. CONVERTING A FEW ROOMS INTO ONE LARGER CLASSROOM.

PROJECT SUMMARY

PROJECT DATA

N 3/32" = 1'-0" | G101A1

1ST FLR LIFE SAFETY PLAN

AREA & OCCUPANCY TABLE

OCCUPANCY CLASSIFICATION

AREA OCCUPANTS

FUNCTION OF SPACE AREA (SF) LOAD FACTOR OCCUPANT LOAD

BUSINESS (B) BUSINESS AREAS 11,253 100 112.5

1ST FLR 11,253 112.5

GRAND TOTAL 11,253 112.5

DEMOLITION NOTES

A. PRIOR TO BEGINNING WORK, NOTIFY ARCHITECT IMMEDIATELY IF DISCREPANCIES

ARE DISCOVERED BETWEEN THE PROPOSED SCOPE OF WORK AND THE EXISTING

CONDITIONS.

B. CONTRACTOR TO COORDINATE DEMOLITION WORK WITH NEW CONSTRUCTION AS

SHOWN ON DRAWINGS. REPORT ANY CONFLICTS TO ARCHITECT BEFORE

DEMOLITION WORK BEGINS.

C. SEE MEP PLANS (IF AVAILABLE) FOR ADDITIONAL DEMOLITION ITEMS AND NOTES.

D. SCOPE OF DEMOLITION AND REMOVAL WORK SHALL NOT BE LIMITED BY THESE

DRAWINGS BUT SHALL INCLUDE ALL WORK NECESSARY TO FACILITATE NEW

CONSTRUCTION.

E. PRIOR TO BIDDING, CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING

CONDITIONS, PRODUCTS TO BE USED, AND QUANTITIES REQUIRED.

F. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN

THIS WORK. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS

ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND

OWNER. OWNER WILL REMOVE HAZARDOUS MATERIALS UNDER A SEPARATE

CONTRACT.

G. REFER TO FINISH PLANS TO IDENTIFY ALL AREAS BEING ALTERED INCLUDING

ROOMS WHERE ALTERATIONS ARE LIMITED TO NEW FINISHES. AT ALL ALTERED

LOCATIONS, REMOVE ALL INTERIOR AND WALL MOUNTED ITEMS. REMOVE ALL

FINISHES AND RESIDUAL GLUE.

H. COORDINATE REMOVAL OF EXISTING CABINETS AND CASEWORK WITH OWNER.

SALVAGE OR REMOVE AS DIRECTED.

I. COORDINATE REMOVAL OF EXISTING DOORS, FRAMES AND HARDWARE WITH

OWNER. SALVAGE OR REMOVE AS DIRECTED.

J. CONTRACTOR TO PROTECT AREAS ADJACENT TO DEMOLITION. ANY

INADVERTENT DAMAGE DONE TO ADJACENT AREAS NOT SPECIFICALLY

SCHEDULED FOR DEMOLITION SHALL BE REPLACED BY THE CONTRACTOR AT NO

CHARGE TO THE OWNER.

K. BUILDING TO REMAIN OPERATIONAL DURING REMODELING/ CONSTRUCTION.

CONTRACTOR TO INSTALL TEMPORARY CONSTRUCTION BARRIERS TO CONTROL

DUST AND PROTECT THE PUBLIC FROM HARM FOR THE DURATION OF ALL

CONSTRUCTION WORK. PROPER EGRESS TO BE MAINTAINED THROUGHOUT

CONSTRUCTION.

N.I.C.

0241-01

0241-01

0241-03

0241-03

0241-10

0241-07

0241-02

0241-05

0241-05

0241-05

0241-04

0241-06

0241-06

0241-06

0241-08 0241-08

0241-11

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR

DEMOLITION PLAN

AD101

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

KEYNOTES PER SHEET

0241-01 REMOVE EXISTING WALL

0241-02 REMOVE EXISTING DOOR, FRAME AND HARDWARE

0241-03 REMOVE EXISTING CASEWORK

0241-04 REMOVE EXISTING WINDOW AND SILL

0241-05 REMOVE EXISTING ACOUSTICAL TILE CEILING AND GRID

0241-06 REMOVE EXISTING CARPET AND WALL BASE

0241-07 REMOVE EXISTING DOOR, FRAME AND HARDWARE. SALVAGE FOR REUSE

0241-08 REMOVE EXISTING MINI-BLINDS

0241-10 REMOVE EXISTING DOOR, FRAME AND HARDWARE. SALVAGE LOCK SET FOR

DOOR 102

0241-11 REMOVE EXISTING LOCK SET. DOOR, FRAME AND OTHER HARDWARE TO REMAIN

N

1/8" = 1'-0" | AD101A1

1ST FLR DEMOLITION PLAN

TYPICAL MOUNTING HEIGHTS AND CLEARANCES

SIDE ELEVATION

WATER CLOSET

ICC A117.1 & ADA STANDARDS

TOILETS & GRAB BARS

FRONT ELEVATION

WATER CLOSET

ICC A117.1 & ADA STANDARDS

URINALS & PARTITIONS

18"

36"

M A

X

TOILETS

SIDE ELEVATION

WATER CLOSET

NON-ACCESSIBLE

M

IN

41"

KNEE & TOE CLEARANCES (NTS)

MINIMUM TOE EXTENSION

UNDER AN ELEMENT

MAXIMUM KNEE AND TOE

EXTENSION UNDER AN

ELEMENT

KNEE CLEARANCE

TOE CLEARANCE

MINIMUM TOE EXTENSION

UNDER AN ELEMENT

(1

1/

2" C

LR

M

IN

M

IN

25" MAX

M

IN

C

LE

A R

17" MIN

9" M

IN

6" MAX 11" MIN

8" MIN

18"

24"

(2

D O

C U

M E

N T

S P

E R

P

LU

M B

IN

G

TOILET PAPER DISPENSERS

NOTES

(1) CLEAR DIMENSION IS FROM BOTTOM OF

GRAB BAR TO ANY PLUMBING COMPONENT

(2) TO TOP OF SEAT

PLAN

WATER CLOSET

ICC A117.1 & ADA STANDARDS

M A

X

TYPICAL@ RECESSED

LAVATORY

12"

24"

18"

M

IN

M

IN

SIDE ELEVATION

FREE-STANDING

ICC A117.1 & ADA STANDARDS

DRINKING FOUNTAINS

M A

X

17"- 19"

SEE KNEE AND TOE

CLEARANCE DIAGRAM

LAVATORIES

SIDE ELEVATION

INSULATED HOT

WATER & DRAIN PIPES

IN SHADED AREA. NO

SHARP OR ABRASIVE

SURFACES.

T O

S P

O U

T

SIDE ELEVATION

FREE-STANDING

NON-ACCESSIBLE

T O

S P

O U

T

PLAN

FREE-STANDING

ICC A117.1 & ADA STANDARDS

MIN TO SPOUT

15"

MIN TO SPOUT

PLAN

RECESSED

ICC A117.1 & ADA STANDARDS

M A

X

30" MIN CLR

M A

X

SEE KNEE AND TOE

CLEARANCE DIAGRAM

RIM OR COUNTER

SURFACE OF LAVATORYMIN

17"

MAXIMUM REACH DEPTH

OF CONTROLS, WATER

FLOW & SOAP DISPENSER

"M

IN

WALL MOUNT

PLAN

18" UNO

PLAN

FRONT ELEVATION

WALL MOUNT

ICC A117.1 & ADA STANDARDS

FRONT ELEVATION

WALL MOUNT

NON-ACCESSIBLE

PLAN

F

LU

S H

C O

N T

R O

L

DIMENSION TO RIM

6"

*18" MIN OR 6" BEYOND LIP

WHICHEVER IS GREATER

M

IN

M A

X

PARTITION

PARTITION

30" MIN

EQ EQ

SIDE ELEVATION

PLAN

M A

X

"17"-19"

AMBULATORY

M

IN

36"

BELOW GRAB BAR

M

IN

ABOVE GRAB BAR

M A

X

C

LE

A R

M

IN

C

LE

A R

1/

2" M

IN

SIDE ELEVATIONS

ICC A117.1 & ADA STANDARDS

24" MIN

42" MAX

24" MIN

36" MAX

GENERAL MOUNTING HEIGHT NOTES

THERMOSTAT (PREFERRED)

SWITCH, LIGHT SENSOR, ETC.

AT DOOR OR CASED OPENING

AUDIBLE AND/OR VISUAL FIRE

ALARM, EMERGENCY AND/OR

SECURITY STROBE LIGHT

1. THE PURPOSE OF THESE DIAGRAMS IS TO

ILLUSTRATE TYPICAL MOUNTING HEIGHTS AND

ASSOCIATED CONFIGURATIONS FOR A

VARIETY OF ITEMS. IT IS THE INTENT OF THE

DESIGN THAT ALL ITEMS SHOWN MOUNTED AT

TYPICAL HEIGHTS BE ACCESSIBLE TO

PERSONS WITH DISABILITIES.

2. THE MOUNTING HEIGHTS, CLEARANCES, AND

CONFIGURATIONS SHOWN ON THIS SHEET

ARE TYPICAL AND SHALL APPLY TO ALL

INSTANCES OF THE ITEM (OR GROUP OF

ITEMS) SHOWN UNLESS SPECIFICALLY NOTED

OR DIMENSIONED OTHERWISE.

3. SEE ADDITIONAL DIAGRAMS FOR ITEMS AND

THEIR ASSOCIATED MOUNTING HEIGHTS.

9"

M

IN

6" M

A X

T O

L E

N S

S U

R F

A C

E M

O U

N T

E D

M A

X F

O R

WALL-MOUNTED EXIT

SIGN AT EXIT DOOR

EXIT

EQ EQ

M O

U N

T O

N S

T R

IK

E

S

ID

E

A

LI

G N

W

IT

H T

O P

O F

A D

JA

C

E N

T F

R A

M E

W H

E N

D

IM

A B

O V

E D

O O

R H

E A

D

2"

IS

2" O

R G

R E

A T

E R

LO

C

A T

E

A

B O

V E

D O

O R

F R

A M

E W

H E

N D

IM

A

B O

V E

D O

O R

H E

A D

9"

" 72

MEDICAL GAS

ZONE VALVE

BOX

MEDICAL GAS

AREA & MASTER

ALARM PANEL

MEDICAL GAS

PANEL

DISCONNECT

SWITCH

ELECTRICAL

PANELBOARD

CLOCK

OR

CLOCK OUTLET

EXIT

SIGNAGE

9"

THERMOSTAT

(ALTERNATE)

POWER RECEPTACLE

CARD READER

OR

DOOR ACTUATOR

LOCAL ALARM

OR

ARMING STATION

FIRE ALARM

PULL STATION

LOCATION

ABOVE

COUNTER

6"

POWER

RECEPTACLE

DATA RECEPTACLE

DATA

RECEPTACLE

WALL

PHONE

GENERAL MOUNTING ALIGNMENT NOTES

1. IN GENERAL, ALL DEVICES SHALL BE ALIGNED

VERTICALLY, AS SHOWN ABOVE.

2. THE PREFERRED THERMOSTAT LOCATION IS

THE LATCH SIDE OF THE DOOR. WHERE THE

LATCH SIDE OF THE DOOR IS LOCATED IN A

CORNER, THE THERMOSTAT SHALL BE

LOCATED ON THE HINGE SIDE.

TYPICAL DEVICE PLACEMENT

SEE ELEVATIONS

FOR LOCATIONS OF

HORIZONTAL

RECEPTACLES

CEILING LINE

O R

L E

S S

O R

G R

E A

T E

R

EXIT

TW00 - TW05

TOWEL BAR

TW10 - TW19

TOWEL SHELF

TW20 - TW29 TW30 - TW39

TOWEL PIN

TW40

TOWEL RING

TW41

FACIAL TISSUE

DISPENSER

MD01 - MD09

SEAT COVER

DISPENSER

MD10 - MD19

SOAP

DISPENSER

MD20 - MD24

CUP

DISPENSER

MD30 - MD39 CH01 - CH19

BABY CHANGING

STATION

CH20 - CH29

CHILD

PROTECTION SEAT

CH30 - CH39

VENDOR

DIAPER PACK

CS00 - CS09

MOP / BROOM HOLDER

CS10 - CS29

UTILITY SHELF

PB00 - PB09

MEDICINE

CABINET

PB10-PB19

TOOTHBRUSH

TUMBLER HOLDER

PB20-PB29

SOAP DISH

(4

8"

4)

M A

X

M A

X

8)

(2

M

IR

R O

R

S H

E

LF

M A

X

WR00 - WR19

M A

X

5)

4" M

IN

TOWEL SHELF

WITH BAR

TOWEL BAR

WITH SOAP DISH

TW TOWEL

CH CHILDCARE

CS CUSTODIAL

(2

(1 0)

MS01

RETRACTABLE

CLOTHESLINE

MS10-11

ROBE HOOK

MS20-21

CLOTHES HOOK

MS05

CLOTHES HOOK

AND BUMPER

(2

(2

MS MISCELLANEOUS

MR01 - MR19

MIRROR

FRAMELESS

MR20 - MR39

MIRROR

FRAME

MS70 - MS79

MIRROR

WITH SHELF

L

A V

M A

X

HAND DRYER

TB00 - TB19

TACKBOARD

VS00 - VS29

COMBINATION VISUAL SURFACES

PAPER TOWEL DISPENSER

(FOLDED)

PD01 - PD03

PAPER TOWEL DISPENSER

(ROLL)

PD10 - PD19

ND01 - ND04

NAPKIN

DISPOSAL

PS00 - PS09

PROJECTION SCREEN

(WALL)

A S

S C

H E

D

AS SCHED

A S

S C

H E

D

AS SCHED

A S

S C

H E

D

AS SCHED

M A

X

6)

(2

M A

X

6)

(2

8"

7)

TP01-02

SINGLE ROLL

DISPENSER

TP10-11

DOUBLE ROLL

DISPENSER

TP20 TP30 TP31TP12

MULTI-ROLL DISP

(SURFACE)

SNGL JUMBO DISP

(SURFACE)

DBL JUMBO DISP

(SURFACE)

DBL ROLL DISP

(PARTITION)

(1

(9

(2

M A

X

T O

M A

X

L A

V

M A

X

PROTRUSION LIMITS

ICC A117.1 & ADA STANDARDS

MAX

4"

7"

(I F

LB

O

R L

E S

S

M A

X

T O

P O

F F

E

T O

F E

H A

N D

LE

M A

X

(8

(3

8"

3)

8"

4)

8"

8)

(1)

(1

(1)

(1

(1)

(1

(9

(1) (1)

(1

(1

TB TACK BOARD

PS PROJ SCREEN

HD HAND DRYER

ND NAPKIN DISP

FE FIRE EXTINGUISHER

(6

(2

M A

X

MD MISCELLANEOUS DISPENSER

MR MIRRORS

PD PAPER TOWEL DISP

T O

M A

X

L A

V

M A

X

R E

F

LE

C T

IV

E

S U

R F

A C

E

R E

F

LE

C T

IV

E

S U

R F

A C

E

PB PRIVATE BATH

DIMENSION NOTES

(1) SEE TP DISPENSER DIAGRAM

FOR ADDITIONAL MOUNTING INFORMATION

(2) NON-ACCESSIBLE

(3) TOP OF SHELF

(4) TOP OF BAR OR PIN

(5) TOP OF WASTE OPENING

(6) TOP OF DISPENSER OPENING

(7) TOP OF HOOK

(8) TOP OF OPERABLE PART

(9) ROLL OUTLET

(10) TOP OF CHANGING BED

(1)

8"

8)

(2

8"

7)

(2

8"

7)

WASTE RECEPTACLE

(TALL & SHORT)

WR WASTE RECEPTACLE

VS VISUAL SURFACE

TP TOILET PAPER DISPENSER

PAPER TOWEL DISPENSERS WITH

WASTE (TALL & SHORT)

M A

X

6)

DR01 - DR19

DR DISPENSER & WASTE

HD01 - HD03

HAND DRYER

(8

HD01 - HD03

SH01

SHOWER

CURTAIN ROD

SHOWER SEAT

(L-SHAPE)

SH11

SHOWER SEAT

(RECTANGLE)

R E

C O

M M

E N

D E

D

9"

9"

SH10

SH SHOWER ACCESSORY

SIDE SIDE

VR01 - VR03 VR04 - VR06

NAPKIN/TAMPON

DISPENSER

NAPKIN/TAMPON DISPENSER

WASTE RECEPTACLE

M A

X

8)

M A

X

8)

VR VENDOR DISPENSER

MARKER BOARDS

ELECTRONIC MARKER BOARDS

A S

S C

H E

D

AS SCHED

MB MARKER BOARD

MB01 - MB59

15"-16"

2 1/2" MAX

22"-23"

1/

2" M

A X

M A

X

D E

P T

H

S T

A

LL

3" M

A X

15"-16"

2 1/2" MAX

1/

2" M

A X

D E

P T

H

S T

A

LL

3" M

A X

PLAN PLAN

CORNER

SHELF

MD40 - MD49

M A

X

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

5)

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

6)

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

6)

D E

E P

P R

O

JE

C T

IO

N

M A

X S

H E

LF

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

0"

-2 5"

D E

E P

P R

O

JE

C T

IO

N

M A

X

6)

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

ADA

REQUIREMENTS

A020

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

FLOOR PLAN NOTES

CEILING PLAN NOTES

CONSTRUCTION NOTES

PARTITION TYPE NOTES

DOOR AND FRAME SCHEDULE

GENERAL NOTES AND REMARKS

A. BEFORE BEGINNING WORK, VERIFY THE EXISTENCE AND LOCATION OF PLUMBING,

MECHANICAL AND ELECTRICAL SYSTEMS AND OTHER CONSTRUCTION AFFECTING

THE WORK. IF DISCREPANCIES ARE DISCOVERED, NOTIFY ARCHITECT PROMPTLY.

B. ALL DIMENSION STRINGS ARE TO FINISH FACE OF WALL, UNLESS NOTED

OTHERWISE

C. REFER TO SHEET A101 FOR REFERENCED PARTITION TYPES AND DETAILS. WALLS

NOT TAGGED ON THESE PLANS SHALL BE PARTITION TYPE S3A-S11.

D. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM BOARD AT THE FOLLOWING

LOCATIONS:

• ENTIRE WALL DIRECTLY BEHIND OR ADJACENT TO ANY PLUMBING

FIXTURE INCLUDING, BUT NOT LIMITED TO, WATER CLOSETS, SHOWERS,

DRINKING FOUNTAINS, SINKS, LAVATORIES AND EYEWASHES.

• ALL WALLS OF AREAS INCLUDING, BUT NOT LIMITED TO, SINGLE

OCCUPANT TOILET ROOMS, JANITOR CLOSETS, SWIMMING POOLS,

THERAPY POOLS, COMMERCIAL KITCHENS, DISHWASHING, ETC.

• WHERE CERAMIC TILE OR SOLID SURFACE WALL CLADDING IS

SCHEDULED, PROVIDE CEMENT BOARD BACKER BOARD IN LIEU OF

GYPSUM BOARD.

E. LOCATE ALL DOOR JAMBS 4" FROM ADJACENT PERPENDICULAR WALL, UNLESS

NOTED OTHERWISE.

F. REPAIR, PATCH AND CLEAN ALL EXISTING SURFACES SCHEDULED TO REMAIN

THAT ARE AFFECTED BY DEMOLITION OR NEW CONSTRUCTION. MAKE APPEAR

NEW, MATCHING ADJACENT CONSTRUCTION. PREPARE ALL SURFACES AS

REQUIRED FOR SCHEDULED FINISHES. SKIM COAT AND PREPARE ALL DAMAGED

OR UNFINISHED SURFACES.

G. PATCH ALL WALL BASE SCARS AT EXISTING WALL SURFACES. PREPARE SMOOTH

TO RECEIVE NEW WALL BASE FOR UNIFORM APPEARANCE.

H. PATCH WALLS TO MATCH ADJACENT SURFACES AT ALL ABANDONED OR REMOVED

OUTLET AND SWITCH LOCATIONS. BLANK COVER PLATES ARE NOT ACCEPTABLE.

I. PREPARE FLOOR LEVEL AND SMOOTH FOR NEW HARD SURFACE FINISHES. PATCH

EXISTING PENETRATIONS AND ABNORMALITIES IN CONCRETE FLOOR.

J. ALL AREAS DISTURBED BY DEMOLITION SHALL BE PATCHED AND PROPERLY

PREPARED FOR NEW FINISH APPLICATIONS. WHERE ADJACENT FINISHES ARE

EXISTING TO REMAIN, PATCH AND MATCH EXISTING FINISHES. CONSULT WITH THE

OWNER TO IDENTIFY ATTIC STOCK AND/OR PREVIOUS MATERIAL SPECIFICATIONS.

K. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR NEW MILLWORK, CASEWORK,

DOOR BUMPERS, ACCESSORIES, EQUIPMENT, FIXTURES, AND OWNER'S WALL-

MOUNTED EQUIPMENT, INCLUDING BUT NOT LIMITED TO, TELEVISIONS/MONITORS,

MARKER BOARDS, TACK BOARDS AND SIGNAGE. OPEN EXISTING WALLS AS

NEEDED TO INSTALL CONCEALED BLOCKING WHERE REQUIRED, AND PATCH

WALLS TO MATCH EXISTING CONSTRUCTION. COORDINATE WITH OWNER ON

LOCATIONS OF WALL-MOUNTED EQUIPMENT.

S11 S3A

CLASSROOM

A101D

ALIGN

N.I.C.

ALIGN

CLASSROOM

ACT-1

8'-2"

5-1/4"

4-7/8"

7-1/4"

(1) LAYER 5/8" TYPE X GYP

BD BOTH SIDES OF SCHED

MTL STUDS, EXTEND TO

UNDERSIDE OF DECK

BOTTOM OF DECK, SEE

STRUCTURAL FOR

SPECIFIC CONDITIONS

1-HR RATED OR

SMOKE TIGHT

WHERE INDICATED ON

LIFE SAFETY SHEETS

FULL HGT & WIDTH

SOUND BATT INSULATION

6" MTL STUDS

4" MTL STUDS

3-5/8" MTL STUDS

S3A - S11

S4A - S11

S6A - S11

PARTITION # DESCRIPTION WIDTH REF TEST STC

SCHEDULED CEILING

(AS OCCURS)

CONTINUOUS SEALANT

@ PERIMETER BOTTOM

& BOTH SIDES ALL

CONDITIONS, TOP @

NON-RATED CONDITIONS

WIDTH

UL U465 45

S2A - S11

UL U465 45

UL U465 45

2-1/2" MTL STUDS 3-3/4"

S1A - S11 1-5/8" MTL STUDS 2-7/8"

S#A

S11

33" x 33 1/2" x 24"

33" x 33 1/2" x 24"

33" x 33 1/2" x 24"

33" x 33 1/2" x 24"

CNTR

25"

PL-2

PULL

PL-1

PL-2

PULL

33" x 24" x 12"

33" x 24" x 12"

33" x 24" x 12"

33" x 24" x 12"

F F

F F

2' -0

2'

-2

/2

2' -9

/2

WIRE PULL - SEE MATERIAL

SCHEDULE

HINGED DOOR

SEE ELEVATIONS

3"

COUNTERTOP. SEE

ELEVATIONS AND MATERIAL

SCHEDULE

BACK/SIDESPLASH WHERE

SHOWN ON ELEVATIONS;

MATCH COUNTERTOP, UNO

1"

ADJUSTABLE SHELF

1 1/2" OC HOLE

FOR SHELF PIN,

TYP

4"

U N

O

S E

E E

LE

V

A T

IO

N

S

SEE ELEVATIONS

S E

E E

LE

V

A T

IO

N

S

(S E

E E

LE

V

A T

IO

N

S

TOE KICK WITH SCHEDULED

BASE, UNO ON ELEVATIONS

WALL TYPE PER PLAN

CONTINUOUS SEALANT

@ PERIMETER TYP

HOLLOW METAL FRAME

DOOR AS SCHEDULED

WALL TYPE PER PLAN

CONTINUOUS SEALANT

@ PERIMETER TYP

HOLLOW METAL FRAME

DOOR AS SCHEDULED

TO NEAREST WALL

4" CLEAR UNO

A. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY MEP CONFLICTS WHICH IMPACT

CEILING CONSTRUCTION PRIOR TO EXECUTING ANY WORK.

B. MINIMUM SIZE FOR PERIMETER CEILING TILES SHALL NOT BE LESS THAN 4" IN ALL

DIRECTIONS.

A. ALL WORK OF THE CONTRACTOR SHALL COMPLY WITH ALL GOVERNING LAWS,

CODES, ORDINANCES, RULES AND REGULATIONS OF THE VILLAGE, COUNTY,

STATE AND GENERAL JURISDICTION.

B. THE DRAWINGS ARE NOT TO BE SCALED.

C. MAINTAIN ACCESS TO ADJACENT PROPERTIES AT ALL TIMES.

D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR

PATCHING THAT MAY BE REQUIRED TO COMPLETE THE WORK.

E. ALL PENETRATIONS THROUGH EXTERIOR WALLS SHALL BE SEALED.

F. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL

BUILDING DIMENSIONS AND SHALL IMMEDIATELY NOTIFY ARCHITECT OF ANY

VARIANCE OR DISCREPANCY AFFECTING CONSTRUCTION.

G. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL PATCHING OF

DISTURBED EXISTING CONDITIONS REQUIRED TO MAINTAIN FIRE RATINGS. FIELD

VERIFICATION OF EXISTING CONDITIONS SHALL BE THE RESPONSIBILITY OF THE

CONTRACTOR. CHANGE ORDERS FOR THIS TYPE OF WORK WILL NOT BE

HONORED.

H. VERIFY ALL ROUGH-IN DIMENSIONS FOR ALL BUILT-IN EQUIPMENT PRIOR TO

PERFORMING WORK.

I. CONTRACTOR SHALL PROVIDE FIRE-TREATED BLOCKING IN WALLS FOR SUPPORT

OF ALL EQUIPMENT, SHELVING, ACCESSORIES AND OTHER DEVICES.

J. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE

FIRESTOPPED USING UL TESTED OR EQUIVALENT TESTING AGENT MATERIALS,

METHODS AND ASSEMBLIES AND MUST PASS LOCAL AUTHORITY INSPECTION.

K. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS

OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS.

L. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED

BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH

INSPECTIONS AND CERTIFICATES OF OCCUPANCY.

A. REFER TO LIFE SAFETY SHEETS (G-SERIES) FOR WALL RATINGS, LOCATIONS AND

REQUIREMENTS.

B. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM BOARD AT THE FOLLOWING

LOCATIONS:

• ENTIRE WALL DIRECTLY BEHIND OR ADJACENT TO ANY PLUMBING

FIXTURE INCLUDING, BUT NOT LIMITED TO, WATER CLOSETS, SHOWERS,

DRINKING FOUNTAINS, SINKS, LAVATORIES AND EYEWASHES.

• ALL WALLS OF AREAS INCLUDING, BUT NOT LIMITED TO, SINGLE

OCCUPANT TOILET ROOMS, JANITOR CLOSETS, SWIMMING POOLS,

THERAPY POOLS, COMMERCIAL KITCHENS, DISHWASHING, ETC.

• WHERE CERAMIC TILE OR SOLID SURFACE WALL CLADDING IS

SCHEDULED, PROVIDE CEMENT BOARD BACKER BOARD IN LIEU OF

GYPSUM BOARD.

C. PROVIDE UL LISTING FIRESTOP ASSEMBLIES AT ALL PENETRATIONS AND

OPENINGS THROUGH RATED WALL ASSEMBLIES TO MATCH FIRE/SMOKE RATING.

D. SEAL ALL PENETRATIONS AND OPENINGS, INCLUDING WALL PERIMETER, AT

SOUND-RATED WALLS.

E. WALL FRAMING AT FIRE/SMOKE DAMPER LOCATIONS SHALL BE COORDINATED

WITH DAMPER MANUFACTURER INSTALLATION REQUIREMENTS.

HINGED DOOR

WIRE PULL - SEE MATERIAL

SCHEDULE

12" CLR MIN

S E

E E

LE

V

A T

IO

N

S

ADJUSTABLE SHELF

1 1/2" OC HOLE FOR SHELF

PIN, TYP

ELEVATIONS

SEE

REMARKS:

1. RELOCATED EXISTING DOOR, FRAME AND HARDWARE

2. EXISTING DOOR AND FRAME WITH SALVAGED LOCKSET

HINGED DOOR

3"

SEE KNEE & TOE CLEARANCE

DIAGRAM SHEET A020

CONTINUOUS SCHEDULED

BASE AND FLOOR

COVERING INSIDE CABINET

WIRE PULL - SEE MATERIAL

SCHEDULE

REMOVABLE PNL

SINK, ACCESSORIES BY

PLUMBING CONTRACTOR,

COORDINATE COUNTERTOP

OPENING, SEE PLUMBING

DOCUMENTS

COUNTERTOP. SEE

ELEVATIONS AND MATERIAL

SCHEDULE

BACK/SIDESPLASH WHERE

SHOWN ON ELEVATIONS;

MATCH COUNTERTOP, UNO

U N

O

S E

E E

LE

V

A T

IO

N

S

1"

SEE ELEVATIONS

S E

E E

LE

V

A T

IO

N

S

SCHEDULED BASE AFFIXED

TO TOE KICK OF OPERABLE

DOOR

ADA TOE KICK BRACKET4"

E E

E

LE

V A

T

IO

N S

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR PLAN, CLG

PLAN, DOOR

SCHEDULE

A101

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

KEYNOTES PER SHEET

0103 INFILL EXISTING WALL; MATCH EXISTING WIDTH, CONSTRUCTION, ACOUSTIC

INSULATION AND ANY SMOKE OR FIRE RATINGS.

0641-24 HINGED DOOR

0641-29 ADJUSTABLE SHELF

0641-32 1 1/2" OC HOLE FOR SHELF PIN

0641-43 REMOVABLE PNL

0641-54 TOE KICK WITH SCHEDULED BASE, UNO ON ELEVATIONS

0641-55 ADA TOE KICK BRACKET

0641-72 WIRE PULL - SEE MATERIAL SCHEDULE

0965-06 CONTINUOUS SCHEDULED BASE AND FLOOR COVERING INSIDE CABINET

0965-07 SCHEDULED BASE AFFIXED TO TOE KICK OF OPERABLE DOOR

1236-01 COUNTERTOP. SEE ELEVATIONS AND MATERIAL SCHEDULE

1236-02 BACK/SIDESPLASH WHERE SHOWN ON ELEVATIONS; MATCH COUNTERTOP, UNO

2242-18 SINK, ACCESSORIES BY PLUMBING CONTRACTOR, COORDINATE COUNTERTOP

OPENING, SEE PLUMBING DOCUMENTS

N 1/8" = 1'-0" | A101A1

1ST FLR PLAN

N 1/8" = 1'-0" | A101A7

1ST FLR CEILING PLAN

3/8" = 1'-0" | A101D1

101 CLASSROOM - NORTH

3/4" = 1'-0" | A101E1

101-102 DOOR

DOOR AND FRAME SCHEDULE

N U

M B

E

R DOOR FRAME

HDWE

TAG

RATING

(MIN) REMARKS N

U M

B E

R

LEAF

QTY

SIZE

TYPE MAT FIN GL TYPE MAT FIN GL

DETAIL

WIDTH HGT HEAD JAMB SILL

1ST FLR

101 1 3'-0" 7'-0" N333 PLAM PT-1 01 HM PT-2 D2/A101 D3/A101 1 101

102 1 3'-0" 7'-0" N333 PLAM -- 01 HM -- -- -- 2 102

3" = 1'-0" | A101D2

HM DOOR HEAD-GYP BD

3" = 1'-0" | A101D3

HM DOOR JAMB-GYP BD

3/4" = 1'-0" | A101E3

301-302 DOOR

3/4" = 1'-0" | A101E2

158 SINK (INTEGRAL BASE) FALSE FRONT

FINISH NOTES

ROOM GENERAL NOTES AND

REMARKS

FINISH PLAN SYMBOLS

REFER TO THIS SHEET A121

FOR ROOM TAG REMARKS

EXISTINGSVF-1

INSTALLATION DIRECTION

FOR FLOORING MATERIAL

EXTENT OF MATERIAL AT

ACCENT WALL

MATERIAL TRANSITION, SEE SHEET

A121 FOR MATERIAL SCHEDULE

FINISH TAG

FLOOR

BASE

WALL

REMARKS

A. REFER TO FINISH PLAN TO IDENTIFY ALL EXISTING AREAS WHERE NEW FINISHES

ARE SCHEDULED. AT SUCH LOCATIONS, REMOVE ALL CURRENT FINISH MATERIALS

AND PREPARE THE SURFACES FOR NEW FINISHES.

B. REPAIR, PATCH AND CLEAN ALL EXISTING SURFACES SCHEDULED TO REMAIN

THAT ARE AFFECTED BY DEMOLITION OR NEW CONSTRUCTION, OR DAMAGED AS

AN EXISTING CONDITION. MAKE APPEAR NEW, MATCHING ADJACENT

CONSTRUCTION. PREPARE ALL SURFACES AS REQUIRED FOR SCHEDULED

FINISHES.

C. PREPARE ALL FLOOR SURFACES SMOOTH AND LEVEL FOR NEW FINISH.

D. PLUG AND PATCH ALL ABANDONED FLOOR PENETRATIONS FLUSH WITH ADJACENT

FLOOR.

E. REPAIR ALL DEMO SCARS SMOOTH FOR NEW FINISHES.

F. PATCH, REPAIR AND SKIM WALL SMOOTH AT LOCATION OF REMOVED WALL BASE.

G. PATCH GYPSUM BOARD AT LOCATIONS WHERE OUTLETS AND THERMOSTATS

HAVE BEEN REMOVED IN EXISTING WALLS TO REMAIN.

H. PATCH ALL WALLS WHERE MILLWORK OR SHELVING HAVE BEEN

REMOVED. PREPARE SMOOTH FOR NEW FINISHES.

I. SKIM COAT SURFACES WHERE WALL COVERING HAS BEEN REMOVED.

J. PREPARE ALL EXISTING WALL SURFACES SMOOTH FOR NEW PAINT.

GENERAL NOTES:

A. SEE CEILING PLAN FOR CEILING FINISH.

B. DOOR TO BE PAINTED PT-1. DOOR FRAME TO BE PAINTED PT-2.

REMARKS:

1. <SAMPLE REMARK>

2. <SAMPLE REMARK>

N.I.C.

CLASSROOM

SVF-1

B-1

PT-1

0965-02

0991-01

0991-01

0965-02 0991-01

SVF-1EXISTING P

T

-3

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR FINISH

PLAN AND

MATERIAL

SCHEDULE

A121

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

KEYNOTES PER SHEET

0965-02 MATCH EXISTING WALL BASE AT AREAS OF NEW CONSTRUCTION

0991-01 PAINT EXISTING WALL AND NEW WALL TO EXTENTS SHOWN WITH PAINT TO

MATCH EXISTING COLOR AND FINISH

N 1/8" = 1'-0" | A121A1

1ST FLR FINISH PLAN

MATERIAL SCHEDULE

FINISH TAG DESCRIPTION MANUFACTURER PRODUCT COLOR FINISH/ INSTALLATION SIZE COMMENT

CEILING

ACT-1 ACOUSTIC CEILING TILE ARMSTRONG 1732 FINE FISSURED ANGLED TEGULAR WITH HUMAGUARD WHITE 15/16" PRELUDE WHITE GRID 2' X 2' X 5/8" THICK CONTACT: BRIAN REICHERT | 815.347.8393 | BMREICHERT@ARMSTRONGCEILINGS.COM

FLOORING

SVF-1 SHEET VINYL FLOOR TBD TBD TBD HEAT WELD SEAMS TBD

MILLWORK

PL-1 PLASTIC LAMINATE WILSONART STANDARD LAMINATE PEWTER MESH 4878 38 FINE VELVET TEXTURE FINISH - COUNTER

PL-2 PLASTIC LAMINATE WILSONART STANDARD LAMINATE STUDIO TEAK 7960 18 LINEARITY FINISH - CABINETS

MISCELLANEOUS

PULL CABINET PULL (TYP.) - U-SHAPED WIRE PULL - SATIN STAINLESS STEEL FINISH 4" O.C., 15/16" DIAMETER FVTC STANDARD

WALL

PT-1 PAINT - WALLS & DOOR SHERWIN WILLIAMS INTERIOR LATEX PAINT SW 1030 SCULPTURE GRAY SEMI-GLOSS FINISH - CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM

PT-2 PAINT - HM DOOR FRAME SHERWIN WILLIAMS INTERIOR LATEX PAINT MATCH BENJAMIN MOORE GALVESTON GRAY AC-27 SEMI-GLOSS FINISH - CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM

PT-3 PAINT - MARKERBOARD SHERWIN WILLIAMS DRY ERASE COATING KB65C2000 WHITE GLOSS FINISH - LEVEL 5 WALL FINISH, MARKERBOARD PAINT TO RUN 3' TO 7' AFF

CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM

WALL BASE

B-1 RESILIENT WALL BASE VPI STANDARD RUBBER WALL BASE, COVED 54 BURNT UMBER ROLL GOODS 4" HIGH, 1/8" THICK FVTC STANDARD

GENERAL NOTES

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

PROVIDE MISCELLANEOUS METALS AND MATERIALS FOR A COMPLETE

INSTALLATION (IE: SUPPORT, BRACING, ETC).

PROVIDE EQUIPMENT SUBMITTAL, FOR REVIEW, IN ACCORDANCE WITH THE

SPECIFICATIONS. DO NOT DELIVER TO THE JOB SITE ANY PRODUCTS WITHOUT

PRIOR REVIEW BY THE ARCHITECT.

PRIOR TO SUBMISSION OF BID, REVIEW A COMPLETE SET OF CONSTRUCTION

DOCUMENTS (INCLUDING ALL OTHER TRADES). INCLUDE ADDITIONAL PIPE OR

DUCT OFF-SETS THAT MAY BE REQUIRED TO CLEAR STRUCTURE, FINISHES OR

WORK OF OTHER TRADES. FIELD VERIFY EXACT LOCATION AND SIZES OF

EXISTING UTILITIES, THE PROPOSED POINT OF CONNECTIONS TO EXISTING

SYSTEMS, AND NEW ROUTINGS. SYSTEM LAYOUTS AS INDICATED ON DRAWINGS

ARE GENERALLY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS

ACTUAL CONSTRUCTION WILL PERMIT.

PROVIDE DUCT ACCESS DOORS FOR EQUIPMENT AND DEVICES REQUIRING

ACCESS OR RESETTING (IE. FIRE AND SMOKE DAMPERS, SMOKE DAMPERS,

SENSORS, ETC) INDICATE SIZE AND LOCATION ON COORDINATED SHOP

DRAWINGS.

PROVIDE MANUAL VOLUME DAMPERS AT EACH GRILLE, REGISTER, AND DIFFUSER.

DO NOT USE VOLUME DAMPERS INTEGRAL WITH GRILLES, DIFFUSERS AND

REGISTERS FOR AIR BALANCING.

INSTALL EQUIPMENT WITH SUFFICIENT ACCESS TO PANELS, ELECTRICAL

CONNECTIONS, CONTROLS, FILTERS, MOTORS, ETC. COORDINATE ACCESS TO ALL

DAMPERS, VALVES, AND OTHER SERVICEABLE EQUIPMENT. REVIEW CEILING

HEIGHTS AND COORDINATE ACCESS PANEL LOCATIONS.

VERIFY DIFFUSERS, GRILLES, AND REGISTER MOUNTING FRAME TYPES WITH

CONSTRUCTION TYPE AND CONFIGURATION.

PAINT ALL VISIBLE INTERIOR PORTIONS OF DUCTWORK FLAT BLACK.

PROTECT AND ISOLATE DUCTS STORED ON CONSTRUCTION SITE FROM DUST

CONTAMINATION.

COORDINATE LOCATION OF SENSORS AND THERMOSTATS WITH ARCHITECT AND

OWNER. COMPLY WITH ADA REQUIREMENTS.

SEE EQUIPMENT SCHEDULES FOR BRANCH PIPE SIZES TO EQUIPMENT, WHERE

PIPE SIZES ARE NOT SHOWN ON PLANS.

COORDINATE WITH DIVISION 26 FOR LOCATION OF POWER AND LOCAL

DISCONNECTS FOR MECHANICAL EQUIPMENT DEVICES. PROVIDE STARTERS FOR

EQUIPMENT WITHOUT VFD ’S, ECM MOTORS, OR EQUIPMENT WITHOUT INTEGRAL

STARTERS.

MAINTAIN MINIMUM ELECTRICAL CODE AND UNIT MANUFACTURER'S CLEARANCES

TO ADJACENT CONSTRUCTION OR EQUIPMENT.GENERAL PIPING SYMBOLS

DIRECTION OF PIPE PITCH (DOWN)

DIRECTION OF FLOW

ANCHOR

REDUCER OR INCREASER

ECCENTRIC REDUCER

TOP CONNECTION, 45° OR 90°

BOTTOM CONNECTION, 45° OR 90°

SIDE CONNECTION

CAPPED OUTLET

RISE OR DROP IN PIPE

UNION

PIPE UP

PIPE DOWN

PIPE GUIDE

INVERTED BUCKET TRAP SET

INCLUDING PIPING ACCESSORIES

SEE DETAIL

FLOAT & THERMOSTATIC TRAP SET

INCLUDING PIPING ACCESSORIES

SEE DETAIL

THERMOSTATIC TRAP SET

INCLUDING PIPING ACCESSORIES

SEE DETAIL

THERMOMETER

PRESSURE GAUGE

FE

BUTTERFLY VALVE

BALL VALVE

MODULATING CONTROL VALVE

TWO POSITION CONTROL VALVE

THREE-WAY MODULATING CONTROL VALVE

THREE-WAY TWO POSITION CONTROL VALVE

PRESSURE REGULATING VALVE

PRESSURE SAFETY VALVE

AUTOMATIC BALANCING CONTROL VALVE

WATER BALANCE DEVICE

CIRCUIT SETTER VALVE

PLUG VALVE

PRESSURE REDUCING VALVE (PRV)

FLOW MEASURING DEVICE

TRIPLE DUTY VALVE

P

FLOW ELEMENT

REFRIGERANT SIGHT GLASS

TEST PLUG (PRESSURE/TEMPERATURE)

AUTOMATIC AIR VENT

MANUAL AIR VENT

STRAINER

ISOLATION VALVE

BALANCING VALVE

GLOBE VALVE

DRAIN VALVE W/ HOSE CONNECTION

CHECK VALVE

WYE STRAINER (WITH VALVE & HOSE

CONNECTION)

WYE STRAINER (WITH VALVE AND QUICK-

COUPLE HOSE CONNECTOR)

FLEXIBLE CONNECTION

ANGLE GLOBE VALVE

FLEX DUCT

BALANCING DAMPER

FIRE DAMPER

ROUND DUCT

DUCT WITH SOUND LINING

ROUND/RADIUS ELBOW

GORED ROUND ELBOW

ROUND TAKEOFF W/

STANDOFF DAMPER

ROUND TAKEOFF - CONICAL

ROUND TEE - CONICAL

VANE ELBOW

RECTANGULAR ELBOW

RECTANGULAR RETURN DUCT

(UP & DOWN)

RECTANGULAR SUPPLY DUCT

(UP & DOWN)

RECTANGULAR EXHAUST DUCT

(UP & DOWN)

ROUND RETURN DUCT

(UP & DOWN)

ROUND SUPPLY DUCT

(UP & DOWN)

ROUND EXHAUST DUCT

(UP & DOWN)

VANE ELBOW & AIR SLIT

TYPE DUCT TAKE-OFF

CONNECT TO EXISTING

LIMIT OF DEMOLITION

COMBINATION FIRE SMOKE DAMPER

MOTORIZED DAMPER

DUCTWORK SYMBOLS PIPING SYMBOLS

14ø

FSD

MOD

FD

BACKDRAFT DAMPER

BDD

EQUIPMENT NOTES

EQUIPMENT TYPE

V-1 EQUIPMENT NUMBER

AIR TERMINAL TYPE & NUMBER

CD-1

(2) 100

NUMBER REQUIRED

AIR TERMINAL CFM

RECTANGULAR DUCT14x14

OVAL DUCT14/14

DUCT WITH LAGGING

GENERAL SYMBOLS

EXISTING

CONDENSATE DRAIND

LOOP WATER RETURN

LOOP WATER SUPPLY

LWR

LWS

DUCT WITH SOUND

LINING AND LAGGING

DEMOLISH

NEW

THERMOSTAT / ROOM SENSOR

HUMIDISTAT

CARBON DIOXIDE MONITOR

POINT OF DEMOLITION

T

H

CO2

F FAN SWITCH/CONTROLLER

TIE IN POINT

CARBON MONOXIDE MONITORCO

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

GENERAL

MECHANICAL

INFORMATION

M000

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

SYMBOL LEGENDABBREVIATIONS

A

B

A/E ARCHITECT / ENGINEER

AAV AUTOMATIC AIR VENT

AD ACCESS DOOR

AF AFTER FILTER

AFF ABOVE FINISHED FLOOR

AFMD AIR FLOW MEASURING DEVICE

AMP AMPERAGE

AP ACCESS PANEL

APD AIR PRESSURE DROP

ASME AMERICAN SOCIETY OF

MECHANICAL ENGINEERS

BDD BACKDRAFT DAMPER

BFP BACKFLOW PREVENTER

BHP BRAKE HORSEPOWER

BOB BOTTOM OF BEAM

BOD BOTTOM OF DUCT

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

CA COMPRESSED AIR

CC COOLING COIL

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CFT CUBIC FEET

CFP CHEMICAL FEED PUMP

CHR CHILLED WATER RETURN

CHS CHILLED WATER SUPPLY

CO CARBON MONOXIDE

COMB COMBUSTION AIR

CO2 CARBON DIOXIDE

COMP COMPRESSOR UNIT

CV CONSTANT VOLUME

CW COLD WATER (POTABLE)

CWP CONDENSER WATER PUMP

CWR CONDENSER WATER RETURN

(TO COOLING TOWER)

CWS CONDENSER WATER SUPPLY

(FROM COOLING TOWER)

dB DECIBELS

DB DRY-BULB TEMPERATURE

DDC DIRECT DIGITAL CONTROLS

DEG DEGREE

DIA DIAMETER

DIW DEIONIZED WATER

DP DEW POINT TEMPERATURE

DPA DIFFERENTIAL PRESSURE ASSEMBLY

DPS DIFFERENTIAL PRESSURE SENSOR

DX DIRECT EXPANSION

F

G

H

C

D

E I

M

N

K

L

O

R

S

P

T

W

U

V

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EER ENERGY EFFICIENCY RATIO

EGS EMERGENCY GAS SHUTOFF

EJ EXPANSION JOINT

EMD END OF MAIN DRIP (STEAM)

ENT ENTERING

ESP EXTERNAL STATIC PRESSURE

EWC EVAPORATIVE WATER COOLER

EWT ENTERING WATER TEMPERATURE

EX EXISTING

F FAHRENHEIT

F&T FLOAT AND THERMOSTATIC TRAP

F/S COMBINATION FIRE SMOKE DAMPER

FA FREE AREA

FC FLEXIBLE CONNECTION

FD FIRE DAMPER

FF FINAL FILTER

FM FLOW METER

FPM FEET PER MINUTE

FPS FEET PER SECOND

FS FLOW SWITCH

FSTAT FREEZESTAT

FT FEET

FV FACE VELOCITY

GA GAUGE

GAL GALLONS

GC GENERAL CONTRACTOR

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GS GALVANIZED STEEL

HD HEAD

HP HORSEPOWER

HPDT HIGH PRESSURE DRIP TRAP

HPR HIGH PRESSURE

RETURN CONDENSATE

HPS HIGH PRESSURE STEAM

HSTAT HUMIDISTAT

HW HEATING WATER

HWR HEATING HOT WATER RETURN

HWS HEATING HOT WATER SUPPLY

I/O INPUT/OUTPUT

ID INSIDE DIAMETER

IN INCH/INCHES

IN HG INCH OF MERCURY

IN WC INCH WATER COLUMN

IN WG INCH WATER GAUGE

kW KILOWATT kWh KILOWATT HOUR

LAT LEAVING AIR TEMPERATURE

LBS/HR POUNDS PER HOUR

LF LINEAR FOOT (FEET)

LH LATENT HEAT

LPG LIQUID PROPANE GAS

LPR LOW PRESSURE

RETURN CONDENSATE

LPS LOW PRESSURE STEAM

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

MA MIXED AIR

MAT MIXED AIR TEMPERATURE

MAV MANUAL AIR VENT

MAX MAXIMUM

MBH 1000 BTUH

MC MECHANICAL CONTRACTOR

MCA MINIMUM BRANCH

CIRCUIT AMPACITY

MERV MINIMUM EFFICIENCY

REPORTING VALUE

MIN MINIMUM

MM MILLIMETER

MOD MOTOR OPERATED DAMPER

MOV MOTOR OPERATED VALVE

MVD MANUAL VOLUME DAMPER

NA NOT APPLICABLE

NC NOISE CRITERIA

NC NORMALLY CLOSED

NG NATURAL GAS

NO NORMALLY OPEN

NOM NOMINAL

NO2 NITROUS DIOXIDE

NTS NOT TO SCALE

OA OUTSIDE AIR

OAI OUTSIDE AIR INTAKE

OD OUTSIDE DIAMETER

PC PLUMBING CONTRACTOR

PCD PUMPED CONDENSATE DISCHARGE

PCF POUNDS PER CUBIC FOOT (FEET)

PD PRESSURE DROP

PF PRE-FILTER

PG PRESSURE GAGE

PPM PARTS PER MILLION

PRV PRESSURE REGULATING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH - ABSOLUTE

PSIG POUNDS PER SQUARE INCH - GAGE

PSV PRESSURE SAFETY VALVE

RA RETURN AIR

RAT RETURN AIR TEMPERATURE

RD REFRIGERANT DISCHARGE

REA RELIEF AIR

RH RELATIVE HUMIDITY

RHG REFRIGERANT HOT GAS

RL REFRIGERANT LIQUID LINE

RLA RUN LOAD AMPERE

RO REVERSE OSMOSIS

RPM REVOLUTIONS PER MINUTE

RS REFRIGERANT SUCTION

RV RELIEF VALVE

SA SUPPLY AIR

SAD SOUND ATTENUATING DEVICE

SAT SUPPLY AIR TEMPERATURE

SC SHADING COEFFICIENT

SCFM STANDARD CUBIC FEET PER MINUTE

SD SMOKE DETECTOR

SD SMOKE DAMPER

SEN SENSIBLE HEAT

SH SENSIBLE HEAT

SI SQUARE INCHES

SP STATIC PRESSURE

SPS STATIC PRESSURE SENSOR

SQ FT SQUARE FOOT (FEET)

SS STAINLESS STEEL

T & P TEMPERATURE AND PRESSURE CONTROL VALVE

TAB TESTING, ADJUSTING, BALANCE

TD TEMPERATURE DIFFERENCE

TOD TOP OF DUCT

TP TRAP

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

UC UNDER CUT

UL UNDERWRITERS LABORATORY

V VALVE

VAV VARIABLE AIR VOLUME

VD VOLUME DAMPER

VFD VARIABLE FREQUENCY DRIVE

W WATTS

WB WET-BULB (TEMPERATURE)

WF WATER FILTER

WFCV WATER FLOW CONTROL VALVE

WFM WATER FLOW METER

WFMD WATER FLOW MEASURING DEVICE

WG WATER GAGE

MECHANICAL SHEET INDEX

M000 GENERAL MECHANICAL INFORMATION

M101 1ST FLR MECHANICAL PLAN

M600 MECHANICAL SCHEDULES & DETAILS

MECHANICAL PLAN NOTES

T

DEMOLITION NOTES

A.

B.

C.

D.

THE MECHANICAL CONTRACTOR SHALL COORDINATE CONSTRUCTION PHASING

WITH THE GENERAL CONTRACTOR AND OWNER. PROVIDE ALL TEMPORARY

PIPING, DUCTWORK , VENTILATION, CONTROLS, ETC. AS REQUIRED TO

ACCOMMODATE CONSTRUCTION PHASE.

REFER TO DUCTWORK PLANS FOR DUCTWORK LINER AND LAGGING.

MECHANICAL CONTRACTOR SHALL VERIFY EQUIPMENT DIMENSIONS PRIOR TO

INSTALLATION AND MAINTAIN ALL MANUFACTURER RECOMMENDED CLEARANCES.

COORDINATE ANY CHANGES IN THE FIELD WITH OTHER TRADES.

CD-2

CD-2

CD-2

CD-2

RG-3

12x12

CLASSROOM

EX 1 1/2" LWS

EX 1 1/2" LWR

EX. 12x10 OA 6ø

HP-7

10x10

22x12 xHP-8

CLASSROOM

xHP-7xHP-8

A.

B.

C.

D.

E.

F.

PRIOR TO CONSTRUCTION, MECHANICAL CONTRACTOR TO PERFORM TEST AND

BALANCE OF EXISTING VENTILATION SYSTEM TO CONFIRM CAPACITY.

VERIFY CONDITION OF EXISTING EQUIPMENT, EXACT SIZES AND LOCATION OF

EXISTING DUCTS AND PIPING, ETC. BEFORE DEMOLITION WORK BEGINS. REPORT

ANY DISCREPANCIES BETWEEN PLANS AND ACTUAL FIELD CONDITIONS TO

ARCHITECT AND ENGINEER PRIOR TO THE COMMENCEMENT OF DEMOLITION

WORK.

REMOVE EXISTING HVAC EQUIPMENT AND ASSOCIATED MATERIALS AS SHOWN

AND TURN OVER TO OWNER OR REMOVE FROM SITE, AS DIRECTED BY OWNER.

COORDINATE CEILING REMOVAL WHICH IS REQUIRED FOR ACCESS TO WORK

THAT IS NOT DESIGNATED FOR REMOVAL. NOTIFY ARCHITECT AND OWNER PRIOR

TO COMMENCING REMOVAL OF EXISTING CEILING WHICH IS DETERMINED TO BE

REQUIRED FOR REMOVAL WORK. REMOVE ONLY THAT PORTION NECESSARY TO

ACCESS AND COMPLETE THE WORK. UPON COMPLETION OF THE ABOVE CEILING

WORK, REPLACE CEILING TO MATCH EXISTING CEILING.

NOTIFY OWNER UPON DISCOVERY OF ANY DUCT DEBRIS, MOLD, ETC. THAT

REQUIRE ADDITIONAL CLEANING PRIOR TO RECONNECTING TO NEW DUCTS.

ANY OPENINGS CREATED IN FLOORS, WALLS, OR ROOFS TO REMAIN ARE TO BE

PATCH AND SEALED TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND

FINISH.

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR

MECHANICAL PLAN

M101

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

KEYNOTES PER SHEET

1 DEMO HEAT PUMP AND ALL ASSOCIATED DUCTWORK, GRILLES, DIFFUSERS, PIPING,

AND CONTROLS.

2 RECONNECT PIPING FROM HEAT PUMP TO MAINS.

3 PROVIDE NEW HEAT PUMP. RECONNECT CONDENSATE TO NEAREST CONDENSATE

PIPING.

4 PROVIDE 6" OUTSIDE AIR INTO RETURN PLENUM ON HEAT PUMP. BALANCE OA TO

130 CFM. REBALANCE SF-1 TO ACHIEVE TO AIRFLOW.

5 DEMO OUTSIDE AIR TO THIS POINT AND PATCH DUCT.

N

1/4" = 1'-0" | M101B4 1ST FLR MECHANICAL PLAN

N

1/4" = 1'-0" | M101B2 1ST FLR DEMOLITION PLAN

1. PROVIDE APPROPRIATE FRAME/BORDER/FLANGE FOR PROPER MOUNTING. REFER TO THE ARCHITECTURAL DRAWINGS FOR SURFACES IN WHICH GRILLES, REGISTERS, AND DIFFUSERS ARE LOCATED.

SUPPLY DUCTWORK

TAKEOFF

WITH VOLUME DAMPER

CEILING

SUPPLY AIR DIFFUSER

PROVIDE HANGER/SUPPORT FOR FLEXIBLE DUCT

AT ELBOW TO PREVENT SAGGING OR KINKS.

FLEXIBLE DUCT

(MAX. LENGTH 5'-0")

R/W = 1.0

LOCKING QUADRANT

VOLUME DAMPER

TYPICAL CONNECTION WHEN BRANCH DUCT DEPTH IS LESS THAN MAIN.

TYPICAL CONNECTION WHEN BRANCH DUCT DEPTH IS THE SAME AS THE MAIN

ROUND BRANCHRECTANGULAR BRANCH

LOCKING QUADRANT

VOLUME DAMPER

CONICAL

FITTING

45.00°

LOCKING QUADRANT

VOLUME DAMPER

AIRFLOW

MANUAL AIR VENT

CONTROL VALVE

BALANCING VALVE

SHUTOFF VALVE (TYP.)

COIL

PIPE CONDENSATE DRAIN

AS SHOWN ON PLANS

NOTE:

LOCATE MANUAL AIR VENT AT HIGH

POINT OF PIPING SERVING UNIT.

P-TRAP

SUPPLY

RETURN

STRAINER

ADAPTER

FLEXIBLE HOSE KIT

TEST PLUG (TYP.)

VIBRATION

ISOLATORS

FLEX CONNECTION

THREADED ROD

ROOF TRUSS

UNISTRUT WASHER & NUT

3H

H

3H

1.

NOTE:

HOLD GYPSUM BOARD BACK 1/4" AND CAULK WALL AIRTIGHT AT INTERSECTION

WITH DUCTWORK.

2. ALL TRANSFER DUCTWORK INTERNALLY LINED WITH 1" DUCT LINER.

ACT

DUCT WITH ACOUSTICAL DUCT

LINER, SEE PLAN FOR SIZE.

MINIMUM 6" OR AS

REQUIRED FOR

LIGHT FIXTURES

PROVIDE SUPPORTS TO

CEILING FRAME OR GRID.

OR STRUCTURE ABOVE

SEE PLAN FOR GRILLE SIZE AND

TYPE, PROVIDE 12" ROUND

ADAPTER. PAINT ALL VISIBLE

PORTIONS FLAT BLACK

BOTTOM OF ROOF TRUSS

12" FLEX DUCT

TAP

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

MECHANICAL

SCHEDULES &

DETAILS

M600

925743

MVL

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

DIFFUSERS, REGISTERS, AND GRILLES

TAG MANUFACTURER MODEL MATERIAL FINISH

GRILLE

FACE

SIZE

GRILLE

NECK

SIZE STYLE

FLOW (CFM)

NC LEVEL AT

MAX FLOW NOTESMIN MAX

CD-2 PRICE SPD STEEL STANDARD WHITE 24X24 8" SQUARE PLAQUE 101 200 1

RG-3 PRICE 80 STEEL STANDARD WHITE 24X24 22X22 1/2" EGGCRATE 501 1200 1

HEAT PUMP SCHEDULE (HP)

UNIT NO.

SUPPLY FAN COOLING DATA

SOURCE

WATER HEATING DATA

COP EER

ELECTRICAL

MANUFACTURER MODEL

WEIGHT

(LBS) NOTES

AIRFLOW

(CFM)

E.S.P.

("WG) HP

TOTAL

MBH

SENSIBLE

MBH

EAT (°F) LAT (°F) EWT

(°F)

LWT

(°F)

FLOW

(GPM)

H2O PD

(FT) MBH

EAT DB

(°F)

LAT DB

(°F)

EWT

(°F)

LWT

(°F) VOLTAGE PHASE MCA MOCPDB WB DB WB

HP-7 580 0.3 0.167 14.8 11.1 80 67 62.8 58.9 95 105 3.75 4 20.2 70 102 70 61 5.4 13 208 1 7.9 15 DAIKIN CCW015 142

1" = 1'-0" | M600A1 DUCT TO CEILING DIFFUSER

1" = 1'-0" | M600A2 TYPICAL BRANCH DUCT TAKE-OFFS

1" = 1'-0" | M600A6 HEAT PUMP COIL PIPING

1" = 1'-0" | M600A4 ACOUSTICAL TRANSFER DUCT

1" = 1'-0" | M600B4 RETURN/TRANSFER DUCT

ENGINEERING DESIGN BY

(800) 362-4505 • www.msa-ps.com

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

ELECTRICAL

SYMBOLS AND

ABBREVIATIONS

E001

925743

LBG

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

ELECTRICAL SHEET LIST

Sheet Number Sheet Name

E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS

ED101 1ST FLR DEMOLITION PLAN - ELECTRICAL

E101 1ST FLR PLANS - ELECTRICAL

ETR

"B"

"A" "J" xHP-7 4 4 xHP-8

ETR

ETR

ETR

ETR

2 3

APPROXIMATELY

1'-0" BELOW CEILING

APPROXIMATELY

2'-0" BELOW CEILING

ETR

ETR

2 2

ETR

APPROXIMATE LOCATION OF

EXISTING DATA RACK SERVING

AREA IN LOWER LEVEL BELOW.

GENERAL NOTES

1. ALL DEVICES AND EQUIPMENT SHOWN DASHED ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED OTHERWISE.

SEE PLAN NOTES FOR SPECIFIC WORK REQUIRED.

2. REMOVE ALL DEVICES AND ASSOCIATED WIRING AND CONDUIT BACK TO PANEL OR HEAD END ON EXISTING WALLS AND CEILINGS SCHEDULED TO BE REMOVED. RE-FEED ANY DEVICES ON SAME CIRCUIT SCHEDULED TO REMAIN.

3. PROVIDE A BLANK STAINLESS STEEL COVER PLATE TO MATCH WIRING DEVICE FACEPLATES ON ALL UNUSED OPENINGS IN WALLS SCHEDULED TO REMAIN. IF OPENING WILL NOT ACCEPT BLANK PLATE, PATCH WALL TO MATCH

EXISTING.

4. DEVICES AND EQUIPMENT SHOWN ON DRAWINGS ARE NOT ALL INCLUSIVE. EVALUATE EXISTING CONDITIONS AND REMOVE ALL ELECTRICAL EQUIPMENT AND DEVICES AS NEEDED TO ACCOMMODATE DEMOLITION OF EXISTING

AREA.

5. VISIT THE PREMISES AND TAKE NOTE OF ALL EXISTING CONDITIONS WHICH MAY AFFECT WORK AND BE RESPONSIBLE FOR KNOWLEDGE OF SAME IN PREPARATION OF BID. LACK OF INFORMATION ON EXISTING

CONDITIONS WILL NOT BE ALLOWED AS A VALID CAUSE FOR ADDITIONAL COMPENSATION.

ENGINEERING DESIGN BY

(800) 362-4505 • www.msa-ps.com

PROJECT MANAGER

PROJECT NUMBER

KEY PLAN

SHEET INFORMATION

PROJECT INFORMATION

ISSUANCE AND REVISIONS

321 654 7

E

D

C

B

A

FVTC VETERINARY

TECHNICIAN

CLASSROOM

REMODEL

1ST FLR

DEMOLITION PLAN -

ELECTRICAL

ED101

925743

LBG

2809 N Park Drive Ln Appleton, WI 54911

© 2025 Eppstein Uhen Architects, Inc.

N

1/8" = 1'-0" | ED101A3

1ST FLR DEMOLITION PLAN - ELECTRICAL

PLAN NOTES

1 DISCONNECT EXISTING MOTOR AND MAINTAIN EXISTING CIRCUIT FROM 15A/2P BREAKER IN PANEL "J" FOR NEW

MOTOR INDICATED ON POWER PLAN.

2 REMOVE ALL EXISTING DEVICES ON EXISTING WALL TO REMAIN UNLESS SPECIFICALLY INDICATED WITH ETR.

3 MAINTAIN EXISTING CIRCUIT FROM PANEL "B" FOR NEW RECEPTACLE INSTALLED IN SAME LOCATION AS INDICATED

ON POWER PLAN.

4 MAINTAIN EXISTING CIRCUIT FROM PANEL "A" SERVING DEMO'D LIGHTING TO SERVE NEW LIGHTING AS SHOWN ON

LIGHTING PLAN.

5 UTILIZE EXISTING DATA JACK AND CABLING FOR NEW DATA JACKS / DEVICE SHOWN ON POWER PLAN. DEMO ANY

UNUSED CABLING BACK TO SOURCE.

X

ETR

C C

C C

P

SP

S D

S D

"B"

"A" "J"

ETR

xHP-8

CLASSROOM

ETR

"B"

"B"

"B"

"B" "B"

CL CL

CL CL

HP-7

"B"

"B"

OS

APPROXIMATE LOCATION OF EXISTING

DATA RACK SERVING AREA IN LOWER

LEVEL BELOW. ANY NEW DATA

CABLING SHALL BE TERMINATED ON

EXISTING FVTC-OWNED PATCH PANEL.

RELOCATE TERMINATION OF EXISTING

DATA CABLING FROM CURRENT PATCH

PANEL TO FVTC-OWNED PATCH PANEL.

P

ETR

APPROXIMATE LOCATION

OF EXISTING FACP IN

LOWER LEVEL BELOW.

C6 C6 C6

C6C6C6

C6 C6 C6

C6C6C6

C6C6

ETR

TO

EXISTING

CKT AND

CONTROL

ETR

ETR

"J"ETR CLASSROOM

GENERAL NOTES - POWER

1. CONFIRM EXACT LOCATION OF ALL OUTLETS WITH OWNER PRIOR TO ROUGH-IN.

2. ALL LOW VOLTAGE CABLING IN AREAS WITH EXPOSED STRUCTURE SHALL BE IN CONDUIT.

2/E101

GENERAL NOTES - LIGHTING

1. ALL TYPE C6 FIXTURES SHALL BE FURNISHED BY OWNER.

2. IN ROOMS WITH OCCUPANCY SENSOR, ALL ILLINATION IN ROOM SHALL BE CONTROLLED BY SENSOR UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR TO DETERMINE BEST LOCATION FOR SENSOR IN FIELD WITH

MANUFACTURER. SEE DETAIL .

3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED LIGHT FIXTURES.

1/E101

SLAVE PAK IF NEEDED

(MORE THAN ONE

CIRCUIT CONTROLLED).

POWER

PAK

NEUTRAL

LIGHTING

CIRCUITHOT

3 CONDUCTOR CABLE.

PROVIDE PLENUM RATED

IN PLENUM SPACES.

MOUNT NEXT TO LIGHTING

FIXTURE OUTLET BOX OR

AT PANELBOARD IF CEILING

SPACE NOT ACCESSIBLE.

3 CONDUCTOR CABLE- PLENUM

RATED IF REQUIRED.

TO ROOM

LIGHTING

FIXTURES.

ROOM LIGHTING SWITCHES

AS SHOWN ON FLOOR PLANS.

MOUNT SENSOR DIRECTLY TO

CEILING OR BOTTOM OF

STRUCTURAL MEMBER

SEE PLANS FOR LOCATION

CEILING

CEILING MOUNTED

MOTION SENSOR

ADDITIONAL SENSORS

IN SAME ROOM IF

SHOWN ON PLANS.

GREEN CAT6 CABLE FROM

IVORY JACK TO PATCH PANEL

IN DATA ROOM

CAT6A

JACK

(BLUE)

A LOW VOLTAGE AT PROJECTOR

B LOW VOLTAGE AT INSTRUCTOR'S STATION

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .