IFB 26021 Drawings.PDF
PDF 10 MB Posted
- Attached to
- Veterinary Technician Classroom Remodel
- Solicitation number
- IFB-26021-0-2025/BJW
- Issued by
- Outagamie County, Wisconsin
About this file
This document is a comprehensive set of construction documents for the Fox Valley Technical College Veterinary Technician Classroom Remodel project, involving Eppstein Uhen Architects and located in Appleton, Wisconsin. The project consists of a 566 square foot interior renovation to convert multiple first-floor rooms into one larger classroom space. The construction documents are dated 09/16/2025 and include architectural, mechanical, and electrical plans detailing the scope of work, which encompasses general trades, HVAC modifications, electrical updates, flooring replacement, acoustical ceiling installation, casework modifications, and painting. The project will be awarded to a single general contractor and involves renovations at 2809 N Park Drive Lane in Appleton.
The project documents indicate a comprehensive renovation approach with specific technical requirements, including the replacement of an existing heat pump, reconfiguration of mechanical systems, electrical device relocations, and careful attention to ADA accessibility standards. The estimated occupant load for the renovated space is 112.5 persons, with the primary occupancy classified as Business (B). While specific pricing details are not explicitly outlined in the documents, the project appears to be funded through Fox Valley Technical College's capital improvement budget. The documents provide extensive technical specifications, including detailed mechanical schedules, electrical plans, and architectural finish requirements, suggesting a thoroughly planned and carefully scoped renovation project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT NUMBER:09/16/2025
FVTC VETERINARY
TECHNICIAN
CLASSROOM REMODEL
925743
CONSTRUCTION DOCUMENTS
IFB 26021
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
ARCHITECTURAL
EPPSTEIN UHEN ARCHITECTS, INC.
1155 Lombardi Avenue, Suite 200 Green Bay, WI 54304
(920) 336-9929 www.eua.com
DIRECT PHONE:
EMAIL ADDRESS:
PROJECT CONTACT:
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
INDEX
G000
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
Matt Van Lanen
(920) 278-0359 mattv@eua.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
MECHANICAL
EPPSTEIN UHEN ARCHITECTS, INC.
1155 Lombardi Avenue, Suite 200 Green Bay, WI 54304
PHONE: (920) 336-9929
www.eua.com
Alex Tessen
(920) 278-0335 alext@eua.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
ELECTRICAL
MSA PROFESSIONAL SERVICES
116 Fremont Street Kiel, WI 53042
PHONE: (920) 894-7800
www.msa-ps.com
Laura Gilbert
(920) 264-0197 lgilbert@msa-ps.com
Map data ©2025 Google
GENERAL
G000 INDEX
G101 1ST FLR LIFE SAFETY PLAN
ARCHITECTURAL DEMOLITION
AD101 1ST FLR DEMOLITION PLAN
ARCHITECTURAL
A020 ADA REQUIREMENTS
A101 1ST FLR PLAN, CLG PLAN, DOOR SCHEDULE
A121 1ST FLR FINISH PLAN AND MATERIAL SCHEDULE
MECHANICAL
M000 GENERAL MECHANICAL INFORMATION
M101 1ST FLR MECHANICAL PLAN
M600 MECHANICAL SCHEDULES & DETAILS
ELECTRICAL
E000 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ED101 1ST FLR DEMOLITION PLAN - ELECTRICAL
E101 1ST FLR PLANS - ELECTRICAL
SHEET INDEXABBREVIATIONS
SYMBOL LEGEND
VICINITY MAP
TRUE
N
PLAN
N
B
000-00
NAME
TYPE
HEIGHT
XXX
XX
FLOOR
BASE
WALL
REMARKS
PARTITION TYPE
DOOR
KEYNOTE
FURNITURE
EQUIPMENT
WINDOW
XX
CEILING
CASEWORK
FINISH PLAN
A
B
A
ELEVATION
DATUM
VIEW NUMBER
VIEW NAME
VIEW SCALE
DEMOLITION
GRID AND GRID IDENTIFICATION
1 2 1 2
A000
A000
SIM
A000
SIM
BUILDING
SECTIONS
OTHER
SECTIONS
CONSTRUCTION PHASES
ELEVATIONS
ROOM
DETAILS
TITLE
1/2" = 1'-0"
DIMENSION REFERENCES
EXISTING NEW
NEWEXISTING
A1
SIM
TAGSCALLOUTS GRAPHICS
NORTH ARROW
TO OBJECT CENTER TO OBJECT FACE
OR OTHER GEOMETRY
EQ EQ EQ 5'-0" 4'-0"
W" x H" x D"
A000
Level 0'-0"
A000-000A
A2
A
A4
A000A
A2
A
A4
A/C air conditioning
A/E Architect/Engineer
ACT acoustical ceiling tile
ADDL additional
ADDM addendum
ADJ adjustable
AFC above finished counter
AFF above finished floor
AFG above finished grade AFS above finished slab
ALT alternate
ALUM aluminum
APPD approved
APT apartment AP acoustical panel
ASC above suspended ceiling
BB baseboard
BLDG building
BLT borrowed lite
BLW below
BPL base plate BO bottom of
BOS bottom of steel
CB catch basin, construction bulletin
CF/CI contractor furnished, contractor installed
CF/OI contractor furnished, owner installed CF/VI contractor furnished, vendor installed
CG corner guard
CIP cast-in-place
CNTR counter CL centerline
CLG ceiling
A
B
C
CLR clear
CM construction management CM construction manager
CMU concrete masonry unit
CO cleanout
COL column
CONC concrete
CORR corridor CPT carpet
CSWK casework
CT ceramic tile
CW cold water
CTB ceramic tile base
DBL double
DEMO demolition
DEPT department
DF drinking fountain DIA diameter
DP decorative panel
DR door
DR FR door frame
DTL detail
DS downspout DW dishwasher
DWG drawing
E east
EIFS exterior insulation & finish system
EL elevation
EJ expansion joint
ELEC electric
ELEC electrical ELEV elevator
EP epoxy
EPS expanded polystyrene board
EQ equal
ETR existing to remain EXIST existing
EXT exterior
F
G
H
F female
F filler
FA fire alarm FA fluid-applied
FAB fabric
FC file cabinet
FD floor drain
FE fire extinguisher
FEC fire extinguisher cabinet
FHC fire hose cabinet
FIN finish
FLR floor
FM factory mutual FM floor mat
FO finished opening
FP fire protection
FP fireproof
FPL fireplace
FRP fiberglass reinforced plastic
FRT fire retardant treated
FTG footing
GA gauge
GALV galvanized
GB grab bar
GC general contractor
GL glass
GLU LAM glue laminated wood
GR grade, grading
GT grout
GYP BD gypsum
HB hose bibb
HC hollow core
HDWE hardware
HM hollow metal
HORIZ horizontal HSKP housekeeping
HGT height
HR hour
HVAC heating, ventilating
& air conditioning HW hot water
HWY highway
T&M time & materials
TEMP temperature
TEMP temporary TER terrazzo
TERB terrazzo base
TFF top of finished floor
TKBD tackboard
TO top of
TOB top of beam TOC top of concrete
TOJ top of joist
TOPO topography
TOS top of slab
TOS top of steel TRNS transom
TYP typical
UNO unless noted otherwise
VERT vertical
VF/CI vendor furnished, contractor installed
VF/OI vendor furnished, owner installed
VF/VI vendor furnished, vendor installed
VNR veneer
VIF verify in field
W west
W/ with
W/O without WC water closet
WC wall covering
WD wood
WDB wood base
WDV wood veneer
WH water heater WP wall protection
WP work point
WT window treatment
XPS extruded polystyrene board
ID inside diameter
INSUL insulation
INT interior
JS janitor sink
LAM laminate LAV lavatory
LF linear foot
LL live load
MAT material MAX maximum
MC modular carpet tile
MECH mechanical
MFR manufacturer
MICRO microwave MIN minimum
MIN minute
MISC miscellaneous
MJ movement joint
MO masonry opening
MS mop sink MTL metal
N north
NA not applicable NIC not in contract
NO number
NM nominal
NS no scale
NTS not to scale
OA overall
OC on center
OD outside diameter
OF/CI owner furnished, contractor installed
OF/OI owner furnished, owner installed
OF/VI owner furnished, vendor installed
OH DR overhead door OPH opposite hand
OPNG opening
PJ panel joint
PLAM plastic laminate
PLYWD plywood PNL panel
PREFAB prefabricated
PREFIN prefinished
PSI pounds per square inch PT paint
PTN partition
QT quarry tile QTB quarry tile base
QTY quantity
QTZ quartz
RB resilient base RCP reflected ceiling plan
RD roof drain
REBAR reinforcing steel bars
REC recess
REF reference REF refrigerator
RF resilient flooring
REV revision
RFS room finish schedule
RO rough opening
S south
SAN sanitary
SC sealed concrete SC solid core
SCHED schedule
SCHED scheduled
SF square foot
SIM sim SL sidelite
SNGL single
SS solid surface
SST stainless steel
ST stain ST stair
STC sound transmission coefficient
STL steel
STN stone STNB stone base
STRUCT structure
C
D
E
I
M
N
J
L
O
Q
R
S
P T
W
X
U
V
PROJECT TEAM
PROJECT LOCATION
DATE DESCRIPTION
09/16/2025 CONSTRUCTION DOCUMENTS
LIFE SAFETY GENERAL NOTES
MEANS OF EGRESS
1. WHEN A WALL HAS MORE THAN ONE CLASSIFICATION, THE MOST RESTRICTIVE REQUIREMENTS FOR EACH CLASSIFICATION SHALL
APPLY.
2. FOR NEW CONSTRUCTION, PERIMETER SMOKE-SEALS MAY BE REQUIRED AT FIRE-RATED DOORS IN CERTAIN OCCUPANCIES.
LIFE SAFETY DRAWING NOTES APPLICABLE TO EXISTING CONDITIONS
EXISTING CONDITIONS INDICATED BY THESE LIFE SAFETY PLANS ARE BASED ON INFORMATION PROVIDED AND AN ANALYSIS OF APPLICABLE CODES. IF EXISTING FIELD CONDITIONS ARE DISCOVERED TO BE DIFFERENT FROM WHAT IS INDICATED ON THESE PLANS, CONTACT THE
ARCHITECT.
WITHIN LIMITS OF NEW CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FOLLOWING AND PATCH
DEFICIENCIES (IF ANY ARE DISCOVERED) OF EXISTING ASSEMBLIES.
• CONTINUITY OF SPRAYED ON FIRE PROTECTION
• CONTINUITY OF FIRE RATINGS AND SMOKE RESISTIVE REQUIREMENTS OF FLOOR ASSEMBLIES
• WALL FIRE RATINGS AND SMOKE RESISTIVE REQUIREMENTS AS INDICATED BY THESE LIFE SAFETY PLANS
• FIRESTOPPING OF THROUGH PENETRATIONS
• FIRESTOPPING OF PERIMETER JOINTS
BUSINESS (B)
11,253 SF
LEVEL 2
ALTERATION
566 SF
34"
34"
112'-11"
TD = 300'
OCCUPANCY LEGEND
BUSINESS (B)
F.E.C.
F.E.C.
F.E.C.
EXIT LOAD BY CALCULATION
EXIT WIDTH REQUIRED
EXIT WIDTH PROVIDED
EXIT LOAD CAPACITY
HORIZONTAL 2-WAY
X" = CLEAR WIDTH OF OPENING IN INCHES
### = OCCUPANT LOAD
HORIZONTAL 1-WAY
X" = CLEAR WIDTH OF OPENING IN INCHES
### = OCCUPANT LOAD
EXIT DISCHARGE
X" = CLEAR WIDTH OF OPENING IN INCHES
### = OCCUPANT LOAD
FROM ROOM OR LEVEL
X" = CLEAR WIDTH OF OPENING IN INCHES
### = OCCUPANT LOAD
X"###
X"###
HE
X"###
HE
X"######X"
AR
AREA OF RESCUE
ASSISTANCE
EXIT PASSAGEWAY
EXIT PASSAGEWAY (SUITE)
EXIT ACCESS
EXIT DISTANCE
X'-X"
VERTICAL EXIT
STAIRWAY
(NON-REQUIRED
MEANS OF EGRESS)
SUITE DESIGNATIONS
HORIZONTAL
RATED ASSEMBLY
HAZARDOUS AREAS
TD = XX'
TRAVEL LENGTH
MAXIMUM TRAVEL DISTANCE
X OCC
XX"
XX"
X OCC
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR LIFE
SAFETY PLAN
G101
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
DESIGN INTENT IS TO MAINTAIN EXISTING QUANTITIES OF PLUMBING FIXTURES. OCCUPANT LOAD OF ANY GIVEN STORY IS NOT BEING INCREASED BY
MORE THAN 20%
MINIMUM PLUMBING FIXTURE REQUIREMENTS CHAPTER 29 SECTION 2902.1
50 FT MAXIMUM
DEAD-END CORRIDOR CHAPTER 10 SECTION 1020.4
100 FT MAXIMUM
COMMON PATH OF TRAVEL CHAPTER 10 SECTION 1006.2.1
300 FT MAXIMUM
EXIT TRAVEL DISTANCE CHAPTER 10 SECTION 1017.2
SEE SEPARATE SCHEDULE(S) FOR CALCULATIONS
OCCUPANT LOAD CHAPTER 10 SECTION 1004
ROOF CONSTRUCTION & SECONDARY
MEMBERS
0 HOUR 0 HOUR
FLOOR CONSTRUCTION & SECONDARY
MEMBERS
0 HOUR 0 HOUR
BEARING WALLS - INTERIOR 0 HOUR 0 HOUR
BEARING WALLS - EXTERIOR 0 HOUR 0 HOUR
PRIMARY STRUCTURAL FRAME 0 HOUR 0 HOUR
REQUIRED PROVIDED
SEE LIFE SAFETY DRAWINGS FOR ADDITIONAL ELEMENTS
REQUIRING FIRE RESISTIVE RATINGS
FIRE RESISTIVE RATINGS CHAPTER 6 SECTION 601
NFPA STANDARD USED 13 CHAPTER 9 SECTION 903.3.1
MONITORING TYPE CENTRAL STATION CHAPTER 9 SECTION 903.4
FIRE SUPPRESSION COMPLETE CHAPTER 9 SECTION 903.2
FIRE ALARM COMPLETE CHAPTER 9 SECTION 907.2
FIRE PROTECTION
FIRST FLOOR 566 SF LEVEL 2
LOWER LEVEL 0 SF
WORK AREA ALTERATION LEVEL
WORK AREA
S-1 (STORAGE)
A-3 (ASSEMBLY)
ACCESSORY OCCUPANCIES CHAPTER 5 SECTION 508.2
B (BUSINESS)
PRIMARY OCCUPANCY CHAPTER 3 SECTION 302
INTERIOR ALTERATION
PROJECT TYPE
TOTAL BUILDING AREA 29,257 SF
NUMBER OF STORIES 2 INCLUDES STORIES ABOVE AND BELOW GRADE
CONSTRUCTION CLASSIFICATION TYPE VB
GENERAL BUILDING INFORMATION
2009 ICC ANSI A117.1 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
2015 INTERNATIONAL BUILDING CODE (IBC) AS MODIFIED BY WISCONSIN CHAPTERS SPS 361 AND 362
2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) AS MODIFIED BY WISCONSIN CHAPTERS SPS 361 AND 366
APPLICABLE BUILDING CODES
FIRE DEPARTMENT: FIRE CHIEF JEREMY HANSEN, 700 N DREW STREET, APPLETON, WI 54911 (920) 832-5810
ZONING: PLANNING DIRECTOR KARA HOMAN, 100 N. APPLETON STREET, APPLETON, WI 54911 (920) 832-6408
BUILDING REVIEW AGENCY: STATE
APPLICABLE JURISDICTION(S)
STATE: WISCONSIN
COUNTY: OUTAGAMIE
MUNICIPALITY: APPLETON
LOCATION
FOX VALLEY TECHNICAL COLLEGE
OWNER
THE PROJECT CONSISTS OF 566 SF OF INTERIOR RENOVATION. CONVERTING A FEW ROOMS INTO ONE LARGER CLASSROOM.
PROJECT SUMMARY
PROJECT DATA
N 3/32" = 1'-0" | G101A1
1ST FLR LIFE SAFETY PLAN
AREA & OCCUPANCY TABLE
OCCUPANCY CLASSIFICATION
AREA OCCUPANTS
FUNCTION OF SPACE AREA (SF) LOAD FACTOR OCCUPANT LOAD
BUSINESS (B) BUSINESS AREAS 11,253 100 112.5
1ST FLR 11,253 112.5
GRAND TOTAL 11,253 112.5
DEMOLITION NOTES
A. PRIOR TO BEGINNING WORK, NOTIFY ARCHITECT IMMEDIATELY IF DISCREPANCIES
ARE DISCOVERED BETWEEN THE PROPOSED SCOPE OF WORK AND THE EXISTING
CONDITIONS.
B. CONTRACTOR TO COORDINATE DEMOLITION WORK WITH NEW CONSTRUCTION AS
SHOWN ON DRAWINGS. REPORT ANY CONFLICTS TO ARCHITECT BEFORE
DEMOLITION WORK BEGINS.
C. SEE MEP PLANS (IF AVAILABLE) FOR ADDITIONAL DEMOLITION ITEMS AND NOTES.
D. SCOPE OF DEMOLITION AND REMOVAL WORK SHALL NOT BE LIMITED BY THESE
DRAWINGS BUT SHALL INCLUDE ALL WORK NECESSARY TO FACILITATE NEW
CONSTRUCTION.
E. PRIOR TO BIDDING, CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING
CONDITIONS, PRODUCTS TO BE USED, AND QUANTITIES REQUIRED.
F. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN
THIS WORK. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS
ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND
OWNER. OWNER WILL REMOVE HAZARDOUS MATERIALS UNDER A SEPARATE
CONTRACT.
G. REFER TO FINISH PLANS TO IDENTIFY ALL AREAS BEING ALTERED INCLUDING
ROOMS WHERE ALTERATIONS ARE LIMITED TO NEW FINISHES. AT ALL ALTERED
LOCATIONS, REMOVE ALL INTERIOR AND WALL MOUNTED ITEMS. REMOVE ALL
FINISHES AND RESIDUAL GLUE.
H. COORDINATE REMOVAL OF EXISTING CABINETS AND CASEWORK WITH OWNER.
SALVAGE OR REMOVE AS DIRECTED.
I. COORDINATE REMOVAL OF EXISTING DOORS, FRAMES AND HARDWARE WITH
OWNER. SALVAGE OR REMOVE AS DIRECTED.
J. CONTRACTOR TO PROTECT AREAS ADJACENT TO DEMOLITION. ANY
INADVERTENT DAMAGE DONE TO ADJACENT AREAS NOT SPECIFICALLY
SCHEDULED FOR DEMOLITION SHALL BE REPLACED BY THE CONTRACTOR AT NO
CHARGE TO THE OWNER.
K. BUILDING TO REMAIN OPERATIONAL DURING REMODELING/ CONSTRUCTION.
CONTRACTOR TO INSTALL TEMPORARY CONSTRUCTION BARRIERS TO CONTROL
DUST AND PROTECT THE PUBLIC FROM HARM FOR THE DURATION OF ALL
CONSTRUCTION WORK. PROPER EGRESS TO BE MAINTAINED THROUGHOUT
CONSTRUCTION.
N.I.C.
0241-01
0241-01
0241-03
0241-03
0241-10
0241-07
0241-02
0241-05
0241-05
0241-05
0241-04
0241-06
0241-06
0241-06
0241-08 0241-08
0241-11
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR
DEMOLITION PLAN
AD101
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
KEYNOTES PER SHEET
0241-01 REMOVE EXISTING WALL
0241-02 REMOVE EXISTING DOOR, FRAME AND HARDWARE
0241-03 REMOVE EXISTING CASEWORK
0241-04 REMOVE EXISTING WINDOW AND SILL
0241-05 REMOVE EXISTING ACOUSTICAL TILE CEILING AND GRID
0241-06 REMOVE EXISTING CARPET AND WALL BASE
0241-07 REMOVE EXISTING DOOR, FRAME AND HARDWARE. SALVAGE FOR REUSE
0241-08 REMOVE EXISTING MINI-BLINDS
0241-10 REMOVE EXISTING DOOR, FRAME AND HARDWARE. SALVAGE LOCK SET FOR
DOOR 102
0241-11 REMOVE EXISTING LOCK SET. DOOR, FRAME AND OTHER HARDWARE TO REMAIN
N
1/8" = 1'-0" | AD101A1
1ST FLR DEMOLITION PLAN
TYPICAL MOUNTING HEIGHTS AND CLEARANCES
SIDE ELEVATION
WATER CLOSET
ICC A117.1 & ADA STANDARDS
TOILETS & GRAB BARS
FRONT ELEVATION
WATER CLOSET
ICC A117.1 & ADA STANDARDS
URINALS & PARTITIONS
18"
36"
M A
X
TOILETS
SIDE ELEVATION
WATER CLOSET
NON-ACCESSIBLE
M
IN
41"
KNEE & TOE CLEARANCES (NTS)
MINIMUM TOE EXTENSION
UNDER AN ELEMENT
MAXIMUM KNEE AND TOE
EXTENSION UNDER AN
ELEMENT
KNEE CLEARANCE
TOE CLEARANCE
MINIMUM TOE EXTENSION
UNDER AN ELEMENT
(1
1/
2" C
LR
M
IN
M
IN
25" MAX
M
IN
C
LE
A R
17" MIN
9" M
IN
6" MAX 11" MIN
8" MIN
18"
24"
(2
D O
C U
M E
N T
S P
E R
P
LU
M B
IN
G
TOILET PAPER DISPENSERS
NOTES
(1) CLEAR DIMENSION IS FROM BOTTOM OF
GRAB BAR TO ANY PLUMBING COMPONENT
(2) TO TOP OF SEAT
PLAN
WATER CLOSET
ICC A117.1 & ADA STANDARDS
M A
X
TYPICAL@ RECESSED
LAVATORY
12"
24"
18"
M
IN
M
IN
SIDE ELEVATION
FREE-STANDING
ICC A117.1 & ADA STANDARDS
DRINKING FOUNTAINS
M A
X
17"- 19"
SEE KNEE AND TOE
CLEARANCE DIAGRAM
LAVATORIES
SIDE ELEVATION
INSULATED HOT
WATER & DRAIN PIPES
IN SHADED AREA. NO
SHARP OR ABRASIVE
SURFACES.
T O
S P
O U
T
SIDE ELEVATION
FREE-STANDING
NON-ACCESSIBLE
T O
S P
O U
T
PLAN
FREE-STANDING
ICC A117.1 & ADA STANDARDS
MIN TO SPOUT
15"
MIN TO SPOUT
PLAN
RECESSED
ICC A117.1 & ADA STANDARDS
M A
X
30" MIN CLR
M A
X
SEE KNEE AND TOE
CLEARANCE DIAGRAM
RIM OR COUNTER
SURFACE OF LAVATORYMIN
17"
MAXIMUM REACH DEPTH
OF CONTROLS, WATER
FLOW & SOAP DISPENSER
"M
IN
WALL MOUNT
PLAN
18" UNO
PLAN
FRONT ELEVATION
WALL MOUNT
ICC A117.1 & ADA STANDARDS
FRONT ELEVATION
WALL MOUNT
NON-ACCESSIBLE
PLAN
F
LU
S H
C O
N T
R O
L
DIMENSION TO RIM
6"
*18" MIN OR 6" BEYOND LIP
WHICHEVER IS GREATER
M
IN
M A
X
PARTITION
PARTITION
30" MIN
EQ EQ
SIDE ELEVATION
PLAN
M A
X
"17"-19"
AMBULATORY
M
IN
36"
BELOW GRAB BAR
M
IN
ABOVE GRAB BAR
M A
X
C
LE
A R
M
IN
C
LE
A R
1/
2" M
IN
SIDE ELEVATIONS
ICC A117.1 & ADA STANDARDS
24" MIN
42" MAX
24" MIN
36" MAX
GENERAL MOUNTING HEIGHT NOTES
THERMOSTAT (PREFERRED)
SWITCH, LIGHT SENSOR, ETC.
AT DOOR OR CASED OPENING
AUDIBLE AND/OR VISUAL FIRE
ALARM, EMERGENCY AND/OR
SECURITY STROBE LIGHT
1. THE PURPOSE OF THESE DIAGRAMS IS TO
ILLUSTRATE TYPICAL MOUNTING HEIGHTS AND
ASSOCIATED CONFIGURATIONS FOR A
VARIETY OF ITEMS. IT IS THE INTENT OF THE
DESIGN THAT ALL ITEMS SHOWN MOUNTED AT
TYPICAL HEIGHTS BE ACCESSIBLE TO
PERSONS WITH DISABILITIES.
2. THE MOUNTING HEIGHTS, CLEARANCES, AND
CONFIGURATIONS SHOWN ON THIS SHEET
ARE TYPICAL AND SHALL APPLY TO ALL
INSTANCES OF THE ITEM (OR GROUP OF
ITEMS) SHOWN UNLESS SPECIFICALLY NOTED
OR DIMENSIONED OTHERWISE.
3. SEE ADDITIONAL DIAGRAMS FOR ITEMS AND
THEIR ASSOCIATED MOUNTING HEIGHTS.
9"
M
IN
6" M
A X
T O
L E
N S
S U
R F
A C
E M
O U
N T
E D
M A
X F
O R
WALL-MOUNTED EXIT
SIGN AT EXIT DOOR
EXIT
EQ EQ
M O
U N
T O
N S
T R
IK
E
S
ID
E
A
LI
G N
W
IT
H T
O P
O F
A D
JA
C
E N
T F
R A
M E
W H
E N
D
IM
A B
O V
E D
O O
R H
E A
D
2"
IS
2" O
R G
R E
A T
E R
LO
C
A T
E
A
B O
V E
D O
O R
F R
A M
E W
H E
N D
IM
A
B O
V E
D O
O R
H E
A D
9"
" 72
MEDICAL GAS
ZONE VALVE
BOX
MEDICAL GAS
AREA & MASTER
ALARM PANEL
MEDICAL GAS
PANEL
DISCONNECT
SWITCH
ELECTRICAL
PANELBOARD
CLOCK
OR
CLOCK OUTLET
EXIT
SIGNAGE
9"
THERMOSTAT
(ALTERNATE)
POWER RECEPTACLE
CARD READER
OR
DOOR ACTUATOR
LOCAL ALARM
OR
ARMING STATION
FIRE ALARM
PULL STATION
LOCATION
ABOVE
COUNTER
6"
POWER
RECEPTACLE
DATA RECEPTACLE
DATA
RECEPTACLE
WALL
PHONE
GENERAL MOUNTING ALIGNMENT NOTES
1. IN GENERAL, ALL DEVICES SHALL BE ALIGNED
VERTICALLY, AS SHOWN ABOVE.
2. THE PREFERRED THERMOSTAT LOCATION IS
THE LATCH SIDE OF THE DOOR. WHERE THE
LATCH SIDE OF THE DOOR IS LOCATED IN A
CORNER, THE THERMOSTAT SHALL BE
LOCATED ON THE HINGE SIDE.
TYPICAL DEVICE PLACEMENT
SEE ELEVATIONS
FOR LOCATIONS OF
HORIZONTAL
RECEPTACLES
CEILING LINE
O R
L E
S S
O R
G R
E A
T E
R
EXIT
TW00 - TW05
TOWEL BAR
TW10 - TW19
TOWEL SHELF
TW20 - TW29 TW30 - TW39
TOWEL PIN
TW40
TOWEL RING
TW41
FACIAL TISSUE
DISPENSER
MD01 - MD09
SEAT COVER
DISPENSER
MD10 - MD19
SOAP
DISPENSER
MD20 - MD24
CUP
DISPENSER
MD30 - MD39 CH01 - CH19
BABY CHANGING
STATION
CH20 - CH29
CHILD
PROTECTION SEAT
CH30 - CH39
VENDOR
DIAPER PACK
CS00 - CS09
MOP / BROOM HOLDER
CS10 - CS29
UTILITY SHELF
PB00 - PB09
MEDICINE
CABINET
PB10-PB19
TOOTHBRUSH
TUMBLER HOLDER
PB20-PB29
SOAP DISH
(4
8"
4)
M A
X
M A
X
8)
(2
M
IR
R O
R
S H
E
LF
M A
X
WR00 - WR19
M A
X
5)
4" M
IN
TOWEL SHELF
WITH BAR
TOWEL BAR
WITH SOAP DISH
TW TOWEL
CH CHILDCARE
CS CUSTODIAL
(2
(1 0)
MS01
RETRACTABLE
CLOTHESLINE
MS10-11
ROBE HOOK
MS20-21
CLOTHES HOOK
MS05
CLOTHES HOOK
AND BUMPER
(2
(2
MS MISCELLANEOUS
MR01 - MR19
MIRROR
FRAMELESS
MR20 - MR39
MIRROR
FRAME
MS70 - MS79
MIRROR
WITH SHELF
L
A V
M A
X
HAND DRYER
TB00 - TB19
TACKBOARD
VS00 - VS29
COMBINATION VISUAL SURFACES
PAPER TOWEL DISPENSER
(FOLDED)
PD01 - PD03
PAPER TOWEL DISPENSER
(ROLL)
PD10 - PD19
ND01 - ND04
NAPKIN
DISPOSAL
PS00 - PS09
PROJECTION SCREEN
(WALL)
A S
S C
H E
D
AS SCHED
A S
S C
H E
D
AS SCHED
A S
S C
H E
D
AS SCHED
M A
X
6)
(2
M A
X
6)
(2
8"
7)
TP01-02
SINGLE ROLL
DISPENSER
TP10-11
DOUBLE ROLL
DISPENSER
TP20 TP30 TP31TP12
MULTI-ROLL DISP
(SURFACE)
SNGL JUMBO DISP
(SURFACE)
DBL JUMBO DISP
(SURFACE)
DBL ROLL DISP
(PARTITION)
(1
(9
(2
M A
X
T O
M A
X
L A
V
M A
X
PROTRUSION LIMITS
ICC A117.1 & ADA STANDARDS
MAX
4"
7"
(I F
LB
O
R L
E S
S
M A
X
T O
P O
F F
E
T O
F E
H A
N D
LE
M A
X
(8
(3
8"
3)
8"
4)
8"
8)
(1)
(1
(1)
(1
(1)
(1
(9
(1) (1)
(1
(1
TB TACK BOARD
PS PROJ SCREEN
HD HAND DRYER
ND NAPKIN DISP
FE FIRE EXTINGUISHER
(6
(2
M A
X
MD MISCELLANEOUS DISPENSER
MR MIRRORS
PD PAPER TOWEL DISP
T O
M A
X
L A
V
M A
X
R E
F
LE
C T
IV
E
S U
R F
A C
E
R E
F
LE
C T
IV
E
S U
R F
A C
E
PB PRIVATE BATH
DIMENSION NOTES
(1) SEE TP DISPENSER DIAGRAM
FOR ADDITIONAL MOUNTING INFORMATION
(2) NON-ACCESSIBLE
(3) TOP OF SHELF
(4) TOP OF BAR OR PIN
(5) TOP OF WASTE OPENING
(6) TOP OF DISPENSER OPENING
(7) TOP OF HOOK
(8) TOP OF OPERABLE PART
(9) ROLL OUTLET
(10) TOP OF CHANGING BED
(1)
8"
8)
(2
8"
7)
(2
8"
7)
WASTE RECEPTACLE
(TALL & SHORT)
WR WASTE RECEPTACLE
VS VISUAL SURFACE
TP TOILET PAPER DISPENSER
PAPER TOWEL DISPENSERS WITH
WASTE (TALL & SHORT)
M A
X
6)
DR01 - DR19
DR DISPENSER & WASTE
HD01 - HD03
HAND DRYER
(8
HD01 - HD03
SH01
SHOWER
CURTAIN ROD
SHOWER SEAT
(L-SHAPE)
SH11
SHOWER SEAT
(RECTANGLE)
R E
C O
M M
E N
D E
D
9"
9"
SH10
SH SHOWER ACCESSORY
SIDE SIDE
VR01 - VR03 VR04 - VR06
NAPKIN/TAMPON
DISPENSER
NAPKIN/TAMPON DISPENSER
WASTE RECEPTACLE
M A
X
8)
M A
X
8)
VR VENDOR DISPENSER
MARKER BOARDS
ELECTRONIC MARKER BOARDS
A S
S C
H E
D
AS SCHED
MB MARKER BOARD
MB01 - MB59
15"-16"
2 1/2" MAX
22"-23"
1/
2" M
A X
M A
X
D E
P T
H
S T
A
LL
3" M
A X
15"-16"
2 1/2" MAX
1/
2" M
A X
D E
P T
H
S T
A
LL
3" M
A X
PLAN PLAN
CORNER
SHELF
MD40 - MD49
M A
X
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
5)
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
6)
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
6)
D E
E P
P R
O
JE
C T
IO
N
M A
X S
H E
LF
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
0"
-2 5"
D E
E P
P R
O
JE
C T
IO
N
M A
X
6)
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
ADA
REQUIREMENTS
A020
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
FLOOR PLAN NOTES
CEILING PLAN NOTES
CONSTRUCTION NOTES
PARTITION TYPE NOTES
DOOR AND FRAME SCHEDULE
GENERAL NOTES AND REMARKS
A. BEFORE BEGINNING WORK, VERIFY THE EXISTENCE AND LOCATION OF PLUMBING,
MECHANICAL AND ELECTRICAL SYSTEMS AND OTHER CONSTRUCTION AFFECTING
THE WORK. IF DISCREPANCIES ARE DISCOVERED, NOTIFY ARCHITECT PROMPTLY.
B. ALL DIMENSION STRINGS ARE TO FINISH FACE OF WALL, UNLESS NOTED
OTHERWISE
C. REFER TO SHEET A101 FOR REFERENCED PARTITION TYPES AND DETAILS. WALLS
NOT TAGGED ON THESE PLANS SHALL BE PARTITION TYPE S3A-S11.
D. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM BOARD AT THE FOLLOWING
LOCATIONS:
• ENTIRE WALL DIRECTLY BEHIND OR ADJACENT TO ANY PLUMBING
FIXTURE INCLUDING, BUT NOT LIMITED TO, WATER CLOSETS, SHOWERS,
DRINKING FOUNTAINS, SINKS, LAVATORIES AND EYEWASHES.
• ALL WALLS OF AREAS INCLUDING, BUT NOT LIMITED TO, SINGLE
OCCUPANT TOILET ROOMS, JANITOR CLOSETS, SWIMMING POOLS,
THERAPY POOLS, COMMERCIAL KITCHENS, DISHWASHING, ETC.
• WHERE CERAMIC TILE OR SOLID SURFACE WALL CLADDING IS
SCHEDULED, PROVIDE CEMENT BOARD BACKER BOARD IN LIEU OF
GYPSUM BOARD.
E. LOCATE ALL DOOR JAMBS 4" FROM ADJACENT PERPENDICULAR WALL, UNLESS
NOTED OTHERWISE.
F. REPAIR, PATCH AND CLEAN ALL EXISTING SURFACES SCHEDULED TO REMAIN
THAT ARE AFFECTED BY DEMOLITION OR NEW CONSTRUCTION. MAKE APPEAR
NEW, MATCHING ADJACENT CONSTRUCTION. PREPARE ALL SURFACES AS
REQUIRED FOR SCHEDULED FINISHES. SKIM COAT AND PREPARE ALL DAMAGED
OR UNFINISHED SURFACES.
G. PATCH ALL WALL BASE SCARS AT EXISTING WALL SURFACES. PREPARE SMOOTH
TO RECEIVE NEW WALL BASE FOR UNIFORM APPEARANCE.
H. PATCH WALLS TO MATCH ADJACENT SURFACES AT ALL ABANDONED OR REMOVED
OUTLET AND SWITCH LOCATIONS. BLANK COVER PLATES ARE NOT ACCEPTABLE.
I. PREPARE FLOOR LEVEL AND SMOOTH FOR NEW HARD SURFACE FINISHES. PATCH
EXISTING PENETRATIONS AND ABNORMALITIES IN CONCRETE FLOOR.
J. ALL AREAS DISTURBED BY DEMOLITION SHALL BE PATCHED AND PROPERLY
PREPARED FOR NEW FINISH APPLICATIONS. WHERE ADJACENT FINISHES ARE
EXISTING TO REMAIN, PATCH AND MATCH EXISTING FINISHES. CONSULT WITH THE
OWNER TO IDENTIFY ATTIC STOCK AND/OR PREVIOUS MATERIAL SPECIFICATIONS.
K. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR NEW MILLWORK, CASEWORK,
DOOR BUMPERS, ACCESSORIES, EQUIPMENT, FIXTURES, AND OWNER'S WALL-
MOUNTED EQUIPMENT, INCLUDING BUT NOT LIMITED TO, TELEVISIONS/MONITORS,
MARKER BOARDS, TACK BOARDS AND SIGNAGE. OPEN EXISTING WALLS AS
NEEDED TO INSTALL CONCEALED BLOCKING WHERE REQUIRED, AND PATCH
WALLS TO MATCH EXISTING CONSTRUCTION. COORDINATE WITH OWNER ON
LOCATIONS OF WALL-MOUNTED EQUIPMENT.
S11 S3A
CLASSROOM
A101D
ALIGN
N.I.C.
ALIGN
CLASSROOM
ACT-1
8'-2"
5-1/4"
4-7/8"
7-1/4"
(1) LAYER 5/8" TYPE X GYP
BD BOTH SIDES OF SCHED
MTL STUDS, EXTEND TO
UNDERSIDE OF DECK
BOTTOM OF DECK, SEE
STRUCTURAL FOR
SPECIFIC CONDITIONS
1-HR RATED OR
SMOKE TIGHT
WHERE INDICATED ON
LIFE SAFETY SHEETS
FULL HGT & WIDTH
SOUND BATT INSULATION
6" MTL STUDS
4" MTL STUDS
3-5/8" MTL STUDS
S3A - S11
S4A - S11
S6A - S11
PARTITION # DESCRIPTION WIDTH REF TEST STC
SCHEDULED CEILING
(AS OCCURS)
CONTINUOUS SEALANT
@ PERIMETER BOTTOM
& BOTH SIDES ALL
CONDITIONS, TOP @
NON-RATED CONDITIONS
WIDTH
UL U465 45
S2A - S11
UL U465 45
UL U465 45
2-1/2" MTL STUDS 3-3/4"
S1A - S11 1-5/8" MTL STUDS 2-7/8"
S#A
S11
33" x 33 1/2" x 24"
33" x 33 1/2" x 24"
33" x 33 1/2" x 24"
33" x 33 1/2" x 24"
CNTR
25"
PL-2
PULL
PL-1
PL-2
PULL
33" x 24" x 12"
33" x 24" x 12"
33" x 24" x 12"
33" x 24" x 12"
F F
F F
2' -0
2'
-2
/2
2' -9
/2
WIRE PULL - SEE MATERIAL
SCHEDULE
HINGED DOOR
SEE ELEVATIONS
3"
COUNTERTOP. SEE
ELEVATIONS AND MATERIAL
SCHEDULE
BACK/SIDESPLASH WHERE
SHOWN ON ELEVATIONS;
MATCH COUNTERTOP, UNO
1"
ADJUSTABLE SHELF
1 1/2" OC HOLE
FOR SHELF PIN,
TYP
4"
U N
O
S E
E E
LE
V
A T
IO
N
S
SEE ELEVATIONS
S E
E E
LE
V
A T
IO
N
S
(S E
E E
LE
V
A T
IO
N
S
TOE KICK WITH SCHEDULED
BASE, UNO ON ELEVATIONS
WALL TYPE PER PLAN
CONTINUOUS SEALANT
@ PERIMETER TYP
HOLLOW METAL FRAME
DOOR AS SCHEDULED
WALL TYPE PER PLAN
CONTINUOUS SEALANT
@ PERIMETER TYP
HOLLOW METAL FRAME
DOOR AS SCHEDULED
TO NEAREST WALL
4" CLEAR UNO
A. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY MEP CONFLICTS WHICH IMPACT
CEILING CONSTRUCTION PRIOR TO EXECUTING ANY WORK.
B. MINIMUM SIZE FOR PERIMETER CEILING TILES SHALL NOT BE LESS THAN 4" IN ALL
DIRECTIONS.
A. ALL WORK OF THE CONTRACTOR SHALL COMPLY WITH ALL GOVERNING LAWS,
CODES, ORDINANCES, RULES AND REGULATIONS OF THE VILLAGE, COUNTY,
STATE AND GENERAL JURISDICTION.
B. THE DRAWINGS ARE NOT TO BE SCALED.
C. MAINTAIN ACCESS TO ADJACENT PROPERTIES AT ALL TIMES.
D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR
PATCHING THAT MAY BE REQUIRED TO COMPLETE THE WORK.
E. ALL PENETRATIONS THROUGH EXTERIOR WALLS SHALL BE SEALED.
F. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL
BUILDING DIMENSIONS AND SHALL IMMEDIATELY NOTIFY ARCHITECT OF ANY
VARIANCE OR DISCREPANCY AFFECTING CONSTRUCTION.
G. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL PATCHING OF
DISTURBED EXISTING CONDITIONS REQUIRED TO MAINTAIN FIRE RATINGS. FIELD
VERIFICATION OF EXISTING CONDITIONS SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. CHANGE ORDERS FOR THIS TYPE OF WORK WILL NOT BE
HONORED.
H. VERIFY ALL ROUGH-IN DIMENSIONS FOR ALL BUILT-IN EQUIPMENT PRIOR TO
PERFORMING WORK.
I. CONTRACTOR SHALL PROVIDE FIRE-TREATED BLOCKING IN WALLS FOR SUPPORT
OF ALL EQUIPMENT, SHELVING, ACCESSORIES AND OTHER DEVICES.
J. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE
FIRESTOPPED USING UL TESTED OR EQUIVALENT TESTING AGENT MATERIALS,
METHODS AND ASSEMBLIES AND MUST PASS LOCAL AUTHORITY INSPECTION.
K. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS
OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS.
L. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED
BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH
INSPECTIONS AND CERTIFICATES OF OCCUPANCY.
A. REFER TO LIFE SAFETY SHEETS (G-SERIES) FOR WALL RATINGS, LOCATIONS AND
REQUIREMENTS.
B. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM BOARD AT THE FOLLOWING
LOCATIONS:
• ENTIRE WALL DIRECTLY BEHIND OR ADJACENT TO ANY PLUMBING
FIXTURE INCLUDING, BUT NOT LIMITED TO, WATER CLOSETS, SHOWERS,
DRINKING FOUNTAINS, SINKS, LAVATORIES AND EYEWASHES.
• ALL WALLS OF AREAS INCLUDING, BUT NOT LIMITED TO, SINGLE
OCCUPANT TOILET ROOMS, JANITOR CLOSETS, SWIMMING POOLS,
THERAPY POOLS, COMMERCIAL KITCHENS, DISHWASHING, ETC.
• WHERE CERAMIC TILE OR SOLID SURFACE WALL CLADDING IS
SCHEDULED, PROVIDE CEMENT BOARD BACKER BOARD IN LIEU OF
GYPSUM BOARD.
C. PROVIDE UL LISTING FIRESTOP ASSEMBLIES AT ALL PENETRATIONS AND
OPENINGS THROUGH RATED WALL ASSEMBLIES TO MATCH FIRE/SMOKE RATING.
D. SEAL ALL PENETRATIONS AND OPENINGS, INCLUDING WALL PERIMETER, AT
SOUND-RATED WALLS.
E. WALL FRAMING AT FIRE/SMOKE DAMPER LOCATIONS SHALL BE COORDINATED
WITH DAMPER MANUFACTURER INSTALLATION REQUIREMENTS.
HINGED DOOR
WIRE PULL - SEE MATERIAL
SCHEDULE
12" CLR MIN
S E
E E
LE
V
A T
IO
N
S
ADJUSTABLE SHELF
1 1/2" OC HOLE FOR SHELF
PIN, TYP
ELEVATIONS
SEE
REMARKS:
1. RELOCATED EXISTING DOOR, FRAME AND HARDWARE
2. EXISTING DOOR AND FRAME WITH SALVAGED LOCKSET
HINGED DOOR
3"
SEE KNEE & TOE CLEARANCE
DIAGRAM SHEET A020
CONTINUOUS SCHEDULED
BASE AND FLOOR
COVERING INSIDE CABINET
WIRE PULL - SEE MATERIAL
SCHEDULE
REMOVABLE PNL
SINK, ACCESSORIES BY
PLUMBING CONTRACTOR,
COORDINATE COUNTERTOP
OPENING, SEE PLUMBING
DOCUMENTS
COUNTERTOP. SEE
ELEVATIONS AND MATERIAL
SCHEDULE
BACK/SIDESPLASH WHERE
SHOWN ON ELEVATIONS;
MATCH COUNTERTOP, UNO
U N
O
S E
E E
LE
V
A T
IO
N
S
1"
SEE ELEVATIONS
S E
E E
LE
V
A T
IO
N
S
SCHEDULED BASE AFFIXED
TO TOE KICK OF OPERABLE
DOOR
ADA TOE KICK BRACKET4"
E E
E
LE
V A
T
IO
N S
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR PLAN, CLG
PLAN, DOOR
SCHEDULE
A101
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
KEYNOTES PER SHEET
0103 INFILL EXISTING WALL; MATCH EXISTING WIDTH, CONSTRUCTION, ACOUSTIC
INSULATION AND ANY SMOKE OR FIRE RATINGS.
0641-24 HINGED DOOR
0641-29 ADJUSTABLE SHELF
0641-32 1 1/2" OC HOLE FOR SHELF PIN
0641-43 REMOVABLE PNL
0641-54 TOE KICK WITH SCHEDULED BASE, UNO ON ELEVATIONS
0641-55 ADA TOE KICK BRACKET
0641-72 WIRE PULL - SEE MATERIAL SCHEDULE
0965-06 CONTINUOUS SCHEDULED BASE AND FLOOR COVERING INSIDE CABINET
0965-07 SCHEDULED BASE AFFIXED TO TOE KICK OF OPERABLE DOOR
1236-01 COUNTERTOP. SEE ELEVATIONS AND MATERIAL SCHEDULE
1236-02 BACK/SIDESPLASH WHERE SHOWN ON ELEVATIONS; MATCH COUNTERTOP, UNO
2242-18 SINK, ACCESSORIES BY PLUMBING CONTRACTOR, COORDINATE COUNTERTOP
OPENING, SEE PLUMBING DOCUMENTS
N 1/8" = 1'-0" | A101A1
1ST FLR PLAN
N 1/8" = 1'-0" | A101A7
1ST FLR CEILING PLAN
3/8" = 1'-0" | A101D1
101 CLASSROOM - NORTH
3/4" = 1'-0" | A101E1
101-102 DOOR
DOOR AND FRAME SCHEDULE
N U
M B
E
R DOOR FRAME
HDWE
TAG
RATING
(MIN) REMARKS N
U M
B E
R
LEAF
QTY
SIZE
TYPE MAT FIN GL TYPE MAT FIN GL
DETAIL
WIDTH HGT HEAD JAMB SILL
1ST FLR
101 1 3'-0" 7'-0" N333 PLAM PT-1 01 HM PT-2 D2/A101 D3/A101 1 101
102 1 3'-0" 7'-0" N333 PLAM -- 01 HM -- -- -- 2 102
3" = 1'-0" | A101D2
HM DOOR HEAD-GYP BD
3" = 1'-0" | A101D3
HM DOOR JAMB-GYP BD
3/4" = 1'-0" | A101E3
301-302 DOOR
3/4" = 1'-0" | A101E2
158 SINK (INTEGRAL BASE) FALSE FRONT
FINISH NOTES
ROOM GENERAL NOTES AND
REMARKS
FINISH PLAN SYMBOLS
REFER TO THIS SHEET A121
FOR ROOM TAG REMARKS
EXISTINGSVF-1
INSTALLATION DIRECTION
FOR FLOORING MATERIAL
EXTENT OF MATERIAL AT
ACCENT WALL
MATERIAL TRANSITION, SEE SHEET
A121 FOR MATERIAL SCHEDULE
FINISH TAG
FLOOR
BASE
WALL
REMARKS
A. REFER TO FINISH PLAN TO IDENTIFY ALL EXISTING AREAS WHERE NEW FINISHES
ARE SCHEDULED. AT SUCH LOCATIONS, REMOVE ALL CURRENT FINISH MATERIALS
AND PREPARE THE SURFACES FOR NEW FINISHES.
B. REPAIR, PATCH AND CLEAN ALL EXISTING SURFACES SCHEDULED TO REMAIN
THAT ARE AFFECTED BY DEMOLITION OR NEW CONSTRUCTION, OR DAMAGED AS
AN EXISTING CONDITION. MAKE APPEAR NEW, MATCHING ADJACENT
CONSTRUCTION. PREPARE ALL SURFACES AS REQUIRED FOR SCHEDULED
FINISHES.
C. PREPARE ALL FLOOR SURFACES SMOOTH AND LEVEL FOR NEW FINISH.
D. PLUG AND PATCH ALL ABANDONED FLOOR PENETRATIONS FLUSH WITH ADJACENT
FLOOR.
E. REPAIR ALL DEMO SCARS SMOOTH FOR NEW FINISHES.
F. PATCH, REPAIR AND SKIM WALL SMOOTH AT LOCATION OF REMOVED WALL BASE.
G. PATCH GYPSUM BOARD AT LOCATIONS WHERE OUTLETS AND THERMOSTATS
HAVE BEEN REMOVED IN EXISTING WALLS TO REMAIN.
H. PATCH ALL WALLS WHERE MILLWORK OR SHELVING HAVE BEEN
REMOVED. PREPARE SMOOTH FOR NEW FINISHES.
I. SKIM COAT SURFACES WHERE WALL COVERING HAS BEEN REMOVED.
J. PREPARE ALL EXISTING WALL SURFACES SMOOTH FOR NEW PAINT.
GENERAL NOTES:
A. SEE CEILING PLAN FOR CEILING FINISH.
B. DOOR TO BE PAINTED PT-1. DOOR FRAME TO BE PAINTED PT-2.
REMARKS:
1. <SAMPLE REMARK>
2. <SAMPLE REMARK>
N.I.C.
CLASSROOM
SVF-1
B-1
PT-1
0965-02
0991-01
0991-01
0965-02 0991-01
SVF-1EXISTING P
T
-3
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR FINISH
PLAN AND
MATERIAL
SCHEDULE
A121
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
KEYNOTES PER SHEET
0965-02 MATCH EXISTING WALL BASE AT AREAS OF NEW CONSTRUCTION
0991-01 PAINT EXISTING WALL AND NEW WALL TO EXTENTS SHOWN WITH PAINT TO
MATCH EXISTING COLOR AND FINISH
N 1/8" = 1'-0" | A121A1
1ST FLR FINISH PLAN
MATERIAL SCHEDULE
FINISH TAG DESCRIPTION MANUFACTURER PRODUCT COLOR FINISH/ INSTALLATION SIZE COMMENT
CEILING
ACT-1 ACOUSTIC CEILING TILE ARMSTRONG 1732 FINE FISSURED ANGLED TEGULAR WITH HUMAGUARD WHITE 15/16" PRELUDE WHITE GRID 2' X 2' X 5/8" THICK CONTACT: BRIAN REICHERT | 815.347.8393 | BMREICHERT@ARMSTRONGCEILINGS.COM
FLOORING
SVF-1 SHEET VINYL FLOOR TBD TBD TBD HEAT WELD SEAMS TBD
MILLWORK
PL-1 PLASTIC LAMINATE WILSONART STANDARD LAMINATE PEWTER MESH 4878 38 FINE VELVET TEXTURE FINISH - COUNTER
PL-2 PLASTIC LAMINATE WILSONART STANDARD LAMINATE STUDIO TEAK 7960 18 LINEARITY FINISH - CABINETS
MISCELLANEOUS
PULL CABINET PULL (TYP.) - U-SHAPED WIRE PULL - SATIN STAINLESS STEEL FINISH 4" O.C., 15/16" DIAMETER FVTC STANDARD
WALL
PT-1 PAINT - WALLS & DOOR SHERWIN WILLIAMS INTERIOR LATEX PAINT SW 1030 SCULPTURE GRAY SEMI-GLOSS FINISH - CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM
PT-2 PAINT - HM DOOR FRAME SHERWIN WILLIAMS INTERIOR LATEX PAINT MATCH BENJAMIN MOORE GALVESTON GRAY AC-27 SEMI-GLOSS FINISH - CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM
PT-3 PAINT - MARKERBOARD SHERWIN WILLIAMS DRY ERASE COATING KB65C2000 WHITE GLOSS FINISH - LEVEL 5 WALL FINISH, MARKERBOARD PAINT TO RUN 3' TO 7' AFF
CONTACT: ANNIE CONWAY | 224.412.1271 | ANNIE.C.CONWAY@SHERWIN.COM
WALL BASE
B-1 RESILIENT WALL BASE VPI STANDARD RUBBER WALL BASE, COVED 54 BURNT UMBER ROLL GOODS 4" HIGH, 1/8" THICK FVTC STANDARD
GENERAL NOTES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
PROVIDE MISCELLANEOUS METALS AND MATERIALS FOR A COMPLETE
INSTALLATION (IE: SUPPORT, BRACING, ETC).
PROVIDE EQUIPMENT SUBMITTAL, FOR REVIEW, IN ACCORDANCE WITH THE
SPECIFICATIONS. DO NOT DELIVER TO THE JOB SITE ANY PRODUCTS WITHOUT
PRIOR REVIEW BY THE ARCHITECT.
PRIOR TO SUBMISSION OF BID, REVIEW A COMPLETE SET OF CONSTRUCTION
DOCUMENTS (INCLUDING ALL OTHER TRADES). INCLUDE ADDITIONAL PIPE OR
DUCT OFF-SETS THAT MAY BE REQUIRED TO CLEAR STRUCTURE, FINISHES OR
WORK OF OTHER TRADES. FIELD VERIFY EXACT LOCATION AND SIZES OF
EXISTING UTILITIES, THE PROPOSED POINT OF CONNECTIONS TO EXISTING
SYSTEMS, AND NEW ROUTINGS. SYSTEM LAYOUTS AS INDICATED ON DRAWINGS
ARE GENERALLY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS
ACTUAL CONSTRUCTION WILL PERMIT.
PROVIDE DUCT ACCESS DOORS FOR EQUIPMENT AND DEVICES REQUIRING
ACCESS OR RESETTING (IE. FIRE AND SMOKE DAMPERS, SMOKE DAMPERS,
SENSORS, ETC) INDICATE SIZE AND LOCATION ON COORDINATED SHOP
DRAWINGS.
PROVIDE MANUAL VOLUME DAMPERS AT EACH GRILLE, REGISTER, AND DIFFUSER.
DO NOT USE VOLUME DAMPERS INTEGRAL WITH GRILLES, DIFFUSERS AND
REGISTERS FOR AIR BALANCING.
INSTALL EQUIPMENT WITH SUFFICIENT ACCESS TO PANELS, ELECTRICAL
CONNECTIONS, CONTROLS, FILTERS, MOTORS, ETC. COORDINATE ACCESS TO ALL
DAMPERS, VALVES, AND OTHER SERVICEABLE EQUIPMENT. REVIEW CEILING
HEIGHTS AND COORDINATE ACCESS PANEL LOCATIONS.
VERIFY DIFFUSERS, GRILLES, AND REGISTER MOUNTING FRAME TYPES WITH
CONSTRUCTION TYPE AND CONFIGURATION.
PAINT ALL VISIBLE INTERIOR PORTIONS OF DUCTWORK FLAT BLACK.
PROTECT AND ISOLATE DUCTS STORED ON CONSTRUCTION SITE FROM DUST
CONTAMINATION.
COORDINATE LOCATION OF SENSORS AND THERMOSTATS WITH ARCHITECT AND
OWNER. COMPLY WITH ADA REQUIREMENTS.
SEE EQUIPMENT SCHEDULES FOR BRANCH PIPE SIZES TO EQUIPMENT, WHERE
PIPE SIZES ARE NOT SHOWN ON PLANS.
COORDINATE WITH DIVISION 26 FOR LOCATION OF POWER AND LOCAL
DISCONNECTS FOR MECHANICAL EQUIPMENT DEVICES. PROVIDE STARTERS FOR
EQUIPMENT WITHOUT VFD ’S, ECM MOTORS, OR EQUIPMENT WITHOUT INTEGRAL
STARTERS.
MAINTAIN MINIMUM ELECTRICAL CODE AND UNIT MANUFACTURER'S CLEARANCES
TO ADJACENT CONSTRUCTION OR EQUIPMENT.GENERAL PIPING SYMBOLS
DIRECTION OF PIPE PITCH (DOWN)
DIRECTION OF FLOW
ANCHOR
REDUCER OR INCREASER
ECCENTRIC REDUCER
TOP CONNECTION, 45° OR 90°
BOTTOM CONNECTION, 45° OR 90°
SIDE CONNECTION
CAPPED OUTLET
RISE OR DROP IN PIPE
UNION
PIPE UP
PIPE DOWN
PIPE GUIDE
INVERTED BUCKET TRAP SET
INCLUDING PIPING ACCESSORIES
SEE DETAIL
FLOAT & THERMOSTATIC TRAP SET
INCLUDING PIPING ACCESSORIES
SEE DETAIL
THERMOSTATIC TRAP SET
INCLUDING PIPING ACCESSORIES
SEE DETAIL
THERMOMETER
PRESSURE GAUGE
FE
BUTTERFLY VALVE
BALL VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
THREE-WAY TWO POSITION CONTROL VALVE
PRESSURE REGULATING VALVE
PRESSURE SAFETY VALVE
AUTOMATIC BALANCING CONTROL VALVE
WATER BALANCE DEVICE
CIRCUIT SETTER VALVE
PLUG VALVE
PRESSURE REDUCING VALVE (PRV)
FLOW MEASURING DEVICE
TRIPLE DUTY VALVE
P
FLOW ELEMENT
REFRIGERANT SIGHT GLASS
TEST PLUG (PRESSURE/TEMPERATURE)
AUTOMATIC AIR VENT
MANUAL AIR VENT
STRAINER
ISOLATION VALVE
BALANCING VALVE
GLOBE VALVE
DRAIN VALVE W/ HOSE CONNECTION
CHECK VALVE
WYE STRAINER (WITH VALVE & HOSE
CONNECTION)
WYE STRAINER (WITH VALVE AND QUICK-
COUPLE HOSE CONNECTOR)
FLEXIBLE CONNECTION
ANGLE GLOBE VALVE
FLEX DUCT
BALANCING DAMPER
FIRE DAMPER
ROUND DUCT
DUCT WITH SOUND LINING
ROUND/RADIUS ELBOW
GORED ROUND ELBOW
ROUND TAKEOFF W/
STANDOFF DAMPER
ROUND TAKEOFF - CONICAL
ROUND TEE - CONICAL
VANE ELBOW
RECTANGULAR ELBOW
RECTANGULAR RETURN DUCT
(UP & DOWN)
RECTANGULAR SUPPLY DUCT
(UP & DOWN)
RECTANGULAR EXHAUST DUCT
(UP & DOWN)
ROUND RETURN DUCT
(UP & DOWN)
ROUND SUPPLY DUCT
(UP & DOWN)
ROUND EXHAUST DUCT
(UP & DOWN)
VANE ELBOW & AIR SLIT
TYPE DUCT TAKE-OFF
CONNECT TO EXISTING
LIMIT OF DEMOLITION
COMBINATION FIRE SMOKE DAMPER
MOTORIZED DAMPER
DUCTWORK SYMBOLS PIPING SYMBOLS
14ø
FSD
MOD
FD
BACKDRAFT DAMPER
BDD
EQUIPMENT NOTES
EQUIPMENT TYPE
V-1 EQUIPMENT NUMBER
AIR TERMINAL TYPE & NUMBER
CD-1
(2) 100
NUMBER REQUIRED
AIR TERMINAL CFM
RECTANGULAR DUCT14x14
OVAL DUCT14/14
DUCT WITH LAGGING
GENERAL SYMBOLS
EXISTING
CONDENSATE DRAIND
LOOP WATER RETURN
LOOP WATER SUPPLY
LWR
LWS
DUCT WITH SOUND
LINING AND LAGGING
DEMOLISH
NEW
THERMOSTAT / ROOM SENSOR
HUMIDISTAT
CARBON DIOXIDE MONITOR
POINT OF DEMOLITION
T
H
CO2
F FAN SWITCH/CONTROLLER
TIE IN POINT
CARBON MONOXIDE MONITORCO
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
GENERAL
MECHANICAL
INFORMATION
M000
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
SYMBOL LEGENDABBREVIATIONS
A
B
A/E ARCHITECT / ENGINEER
AAV AUTOMATIC AIR VENT
AD ACCESS DOOR
AF AFTER FILTER
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AMP AMPERAGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ASME AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BOB BOTTOM OF BEAM
BOD BOTTOM OF DUCT
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CA COMPRESSED AIR
CC COOLING COIL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CO CARBON MONOXIDE
COMB COMBUSTION AIR
CO2 CARBON DIOXIDE
COMP COMPRESSOR UNIT
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN
(TO COOLING TOWER)
CWS CONDENSER WATER SUPPLY
(FROM COOLING TOWER)
dB DECIBELS
DB DRY-BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
F
G
H
C
D
E I
M
N
K
L
O
R
S
P
T
W
U
V
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
EER ENERGY EFFICIENCY RATIO
EGS EMERGENCY GAS SHUTOFF
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC TRAP
F/S COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FD FIRE DAMPER
FF FINAL FILTER
FM FLOW METER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GS GALVANIZED STEEL
HD HEAD
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE
RETURN CONDENSATE
HPS HIGH PRESSURE STEAM
HSTAT HUMIDISTAT
HW HEATING WATER
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
I/O INPUT/OUTPUT
ID INSIDE DIAMETER
IN INCH/INCHES
IN HG INCH OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
kW KILOWATT kWh KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LH LATENT HEAT
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE
RETURN CONDENSATE
LPS LOW PRESSURE STEAM
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH 1000 BTUH
MC MECHANICAL CONTRACTOR
MCA MINIMUM BRANCH
CIRCUIT AMPACITY
MERV MINIMUM EFFICIENCY
REPORTING VALUE
MIN MINIMUM
MM MILLIMETER
MOD MOTOR OPERATED DAMPER
MOV MOTOR OPERATED VALVE
MVD MANUAL VOLUME DAMPER
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NO NORMALLY OPEN
NOM NOMINAL
NO2 NITROUS DIOXIDE
NTS NOT TO SCALE
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
PC PLUMBING CONTRACTOR
PCD PUMPED CONDENSATE DISCHARGE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PF PRE-FILTER
PG PRESSURE GAGE
PPM PARTS PER MILLION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH - ABSOLUTE
PSIG POUNDS PER SQUARE INCH - GAGE
PSV PRESSURE SAFETY VALVE
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RD REFRIGERANT DISCHARGE
REA RELIEF AIR
RH RELATIVE HUMIDITY
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
RV RELIEF VALVE
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SD SMOKE DETECTOR
SD SMOKE DAMPER
SEN SENSIBLE HEAT
SH SENSIBLE HEAT
SI SQUARE INCHES
SP STATIC PRESSURE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SS STAINLESS STEEL
T & P TEMPERATURE AND PRESSURE CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TOD TOP OF DUCT
TP TRAP
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
UC UNDER CUT
UL UNDERWRITERS LABORATORY
V VALVE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
W WATTS
WB WET-BULB (TEMPERATURE)
WF WATER FILTER
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOW METER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
MECHANICAL SHEET INDEX
M000 GENERAL MECHANICAL INFORMATION
M101 1ST FLR MECHANICAL PLAN
M600 MECHANICAL SCHEDULES & DETAILS
MECHANICAL PLAN NOTES
T
DEMOLITION NOTES
A.
B.
C.
D.
THE MECHANICAL CONTRACTOR SHALL COORDINATE CONSTRUCTION PHASING
WITH THE GENERAL CONTRACTOR AND OWNER. PROVIDE ALL TEMPORARY
PIPING, DUCTWORK , VENTILATION, CONTROLS, ETC. AS REQUIRED TO
ACCOMMODATE CONSTRUCTION PHASE.
REFER TO DUCTWORK PLANS FOR DUCTWORK LINER AND LAGGING.
MECHANICAL CONTRACTOR SHALL VERIFY EQUIPMENT DIMENSIONS PRIOR TO
INSTALLATION AND MAINTAIN ALL MANUFACTURER RECOMMENDED CLEARANCES.
COORDINATE ANY CHANGES IN THE FIELD WITH OTHER TRADES.
CD-2
CD-2
CD-2
CD-2
RG-3
12x12
CLASSROOM
EX 1 1/2" LWS
EX 1 1/2" LWR
EX. 12x10 OA 6ø
HP-7
10x10
22x12 xHP-8
CLASSROOM
xHP-7xHP-8
A.
B.
C.
D.
E.
F.
PRIOR TO CONSTRUCTION, MECHANICAL CONTRACTOR TO PERFORM TEST AND
BALANCE OF EXISTING VENTILATION SYSTEM TO CONFIRM CAPACITY.
VERIFY CONDITION OF EXISTING EQUIPMENT, EXACT SIZES AND LOCATION OF
EXISTING DUCTS AND PIPING, ETC. BEFORE DEMOLITION WORK BEGINS. REPORT
ANY DISCREPANCIES BETWEEN PLANS AND ACTUAL FIELD CONDITIONS TO
ARCHITECT AND ENGINEER PRIOR TO THE COMMENCEMENT OF DEMOLITION
WORK.
REMOVE EXISTING HVAC EQUIPMENT AND ASSOCIATED MATERIALS AS SHOWN
AND TURN OVER TO OWNER OR REMOVE FROM SITE, AS DIRECTED BY OWNER.
COORDINATE CEILING REMOVAL WHICH IS REQUIRED FOR ACCESS TO WORK
THAT IS NOT DESIGNATED FOR REMOVAL. NOTIFY ARCHITECT AND OWNER PRIOR
TO COMMENCING REMOVAL OF EXISTING CEILING WHICH IS DETERMINED TO BE
REQUIRED FOR REMOVAL WORK. REMOVE ONLY THAT PORTION NECESSARY TO
ACCESS AND COMPLETE THE WORK. UPON COMPLETION OF THE ABOVE CEILING
WORK, REPLACE CEILING TO MATCH EXISTING CEILING.
NOTIFY OWNER UPON DISCOVERY OF ANY DUCT DEBRIS, MOLD, ETC. THAT
REQUIRE ADDITIONAL CLEANING PRIOR TO RECONNECTING TO NEW DUCTS.
ANY OPENINGS CREATED IN FLOORS, WALLS, OR ROOFS TO REMAIN ARE TO BE
PATCH AND SEALED TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR
MECHANICAL PLAN
M101
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
KEYNOTES PER SHEET
1 DEMO HEAT PUMP AND ALL ASSOCIATED DUCTWORK, GRILLES, DIFFUSERS, PIPING,
AND CONTROLS.
2 RECONNECT PIPING FROM HEAT PUMP TO MAINS.
3 PROVIDE NEW HEAT PUMP. RECONNECT CONDENSATE TO NEAREST CONDENSATE
PIPING.
4 PROVIDE 6" OUTSIDE AIR INTO RETURN PLENUM ON HEAT PUMP. BALANCE OA TO
130 CFM. REBALANCE SF-1 TO ACHIEVE TO AIRFLOW.
5 DEMO OUTSIDE AIR TO THIS POINT AND PATCH DUCT.
N
1/4" = 1'-0" | M101B4 1ST FLR MECHANICAL PLAN
N
1/4" = 1'-0" | M101B2 1ST FLR DEMOLITION PLAN
1. PROVIDE APPROPRIATE FRAME/BORDER/FLANGE FOR PROPER MOUNTING. REFER TO THE ARCHITECTURAL DRAWINGS FOR SURFACES IN WHICH GRILLES, REGISTERS, AND DIFFUSERS ARE LOCATED.
SUPPLY DUCTWORK
TAKEOFF
WITH VOLUME DAMPER
CEILING
SUPPLY AIR DIFFUSER
PROVIDE HANGER/SUPPORT FOR FLEXIBLE DUCT
AT ELBOW TO PREVENT SAGGING OR KINKS.
FLEXIBLE DUCT
(MAX. LENGTH 5'-0")
R/W = 1.0
LOCKING QUADRANT
VOLUME DAMPER
TYPICAL CONNECTION WHEN BRANCH DUCT DEPTH IS LESS THAN MAIN.
TYPICAL CONNECTION WHEN BRANCH DUCT DEPTH IS THE SAME AS THE MAIN
ROUND BRANCHRECTANGULAR BRANCH
LOCKING QUADRANT
VOLUME DAMPER
CONICAL
FITTING
45.00°
LOCKING QUADRANT
VOLUME DAMPER
AIRFLOW
MANUAL AIR VENT
CONTROL VALVE
BALANCING VALVE
SHUTOFF VALVE (TYP.)
COIL
PIPE CONDENSATE DRAIN
AS SHOWN ON PLANS
NOTE:
LOCATE MANUAL AIR VENT AT HIGH
POINT OF PIPING SERVING UNIT.
P-TRAP
SUPPLY
RETURN
STRAINER
ADAPTER
FLEXIBLE HOSE KIT
TEST PLUG (TYP.)
VIBRATION
ISOLATORS
FLEX CONNECTION
THREADED ROD
ROOF TRUSS
UNISTRUT WASHER & NUT
3H
H
3H
1.
NOTE:
HOLD GYPSUM BOARD BACK 1/4" AND CAULK WALL AIRTIGHT AT INTERSECTION
WITH DUCTWORK.
2. ALL TRANSFER DUCTWORK INTERNALLY LINED WITH 1" DUCT LINER.
ACT
DUCT WITH ACOUSTICAL DUCT
LINER, SEE PLAN FOR SIZE.
MINIMUM 6" OR AS
REQUIRED FOR
LIGHT FIXTURES
PROVIDE SUPPORTS TO
CEILING FRAME OR GRID.
OR STRUCTURE ABOVE
SEE PLAN FOR GRILLE SIZE AND
TYPE, PROVIDE 12" ROUND
ADAPTER. PAINT ALL VISIBLE
PORTIONS FLAT BLACK
BOTTOM OF ROOF TRUSS
12" FLEX DUCT
TAP
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
MECHANICAL
SCHEDULES &
DETAILS
M600
925743
MVL
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
DIFFUSERS, REGISTERS, AND GRILLES
TAG MANUFACTURER MODEL MATERIAL FINISH
GRILLE
FACE
SIZE
GRILLE
NECK
SIZE STYLE
FLOW (CFM)
NC LEVEL AT
MAX FLOW NOTESMIN MAX
CD-2 PRICE SPD STEEL STANDARD WHITE 24X24 8" SQUARE PLAQUE 101 200 1
RG-3 PRICE 80 STEEL STANDARD WHITE 24X24 22X22 1/2" EGGCRATE 501 1200 1
HEAT PUMP SCHEDULE (HP)
UNIT NO.
SUPPLY FAN COOLING DATA
SOURCE
WATER HEATING DATA
COP EER
ELECTRICAL
MANUFACTURER MODEL
WEIGHT
(LBS) NOTES
AIRFLOW
(CFM)
E.S.P.
("WG) HP
TOTAL
MBH
SENSIBLE
MBH
EAT (°F) LAT (°F) EWT
(°F)
LWT
(°F)
FLOW
(GPM)
H2O PD
(FT) MBH
EAT DB
(°F)
LAT DB
(°F)
EWT
(°F)
LWT
(°F) VOLTAGE PHASE MCA MOCPDB WB DB WB
HP-7 580 0.3 0.167 14.8 11.1 80 67 62.8 58.9 95 105 3.75 4 20.2 70 102 70 61 5.4 13 208 1 7.9 15 DAIKIN CCW015 142
1" = 1'-0" | M600A1 DUCT TO CEILING DIFFUSER
1" = 1'-0" | M600A2 TYPICAL BRANCH DUCT TAKE-OFFS
1" = 1'-0" | M600A6 HEAT PUMP COIL PIPING
1" = 1'-0" | M600A4 ACOUSTICAL TRANSFER DUCT
1" = 1'-0" | M600B4 RETURN/TRANSFER DUCT
ENGINEERING DESIGN BY
(800) 362-4505 • www.msa-ps.com
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
ELECTRICAL
SYMBOLS AND
ABBREVIATIONS
E001
925743
LBG
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
ELECTRICAL SHEET LIST
Sheet Number Sheet Name
E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ED101 1ST FLR DEMOLITION PLAN - ELECTRICAL
E101 1ST FLR PLANS - ELECTRICAL
ETR
"B"
"A" "J" xHP-7 4 4 xHP-8
ETR
ETR
ETR
ETR
2 3
APPROXIMATELY
1'-0" BELOW CEILING
APPROXIMATELY
2'-0" BELOW CEILING
ETR
ETR
2 2
ETR
APPROXIMATE LOCATION OF
EXISTING DATA RACK SERVING
AREA IN LOWER LEVEL BELOW.
GENERAL NOTES
1. ALL DEVICES AND EQUIPMENT SHOWN DASHED ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED OTHERWISE.
SEE PLAN NOTES FOR SPECIFIC WORK REQUIRED.
2. REMOVE ALL DEVICES AND ASSOCIATED WIRING AND CONDUIT BACK TO PANEL OR HEAD END ON EXISTING WALLS AND CEILINGS SCHEDULED TO BE REMOVED. RE-FEED ANY DEVICES ON SAME CIRCUIT SCHEDULED TO REMAIN.
3. PROVIDE A BLANK STAINLESS STEEL COVER PLATE TO MATCH WIRING DEVICE FACEPLATES ON ALL UNUSED OPENINGS IN WALLS SCHEDULED TO REMAIN. IF OPENING WILL NOT ACCEPT BLANK PLATE, PATCH WALL TO MATCH
EXISTING.
4. DEVICES AND EQUIPMENT SHOWN ON DRAWINGS ARE NOT ALL INCLUSIVE. EVALUATE EXISTING CONDITIONS AND REMOVE ALL ELECTRICAL EQUIPMENT AND DEVICES AS NEEDED TO ACCOMMODATE DEMOLITION OF EXISTING
AREA.
5. VISIT THE PREMISES AND TAKE NOTE OF ALL EXISTING CONDITIONS WHICH MAY AFFECT WORK AND BE RESPONSIBLE FOR KNOWLEDGE OF SAME IN PREPARATION OF BID. LACK OF INFORMATION ON EXISTING
CONDITIONS WILL NOT BE ALLOWED AS A VALID CAUSE FOR ADDITIONAL COMPENSATION.
ENGINEERING DESIGN BY
(800) 362-4505 • www.msa-ps.com
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
321 654 7
E
D
C
B
A
FVTC VETERINARY
TECHNICIAN
CLASSROOM
REMODEL
1ST FLR
DEMOLITION PLAN -
ELECTRICAL
ED101
925743
LBG
2809 N Park Drive Ln Appleton, WI 54911
© 2025 Eppstein Uhen Architects, Inc.
N
1/8" = 1'-0" | ED101A3
1ST FLR DEMOLITION PLAN - ELECTRICAL
PLAN NOTES
1 DISCONNECT EXISTING MOTOR AND MAINTAIN EXISTING CIRCUIT FROM 15A/2P BREAKER IN PANEL "J" FOR NEW
MOTOR INDICATED ON POWER PLAN.
2 REMOVE ALL EXISTING DEVICES ON EXISTING WALL TO REMAIN UNLESS SPECIFICALLY INDICATED WITH ETR.
3 MAINTAIN EXISTING CIRCUIT FROM PANEL "B" FOR NEW RECEPTACLE INSTALLED IN SAME LOCATION AS INDICATED
ON POWER PLAN.
4 MAINTAIN EXISTING CIRCUIT FROM PANEL "A" SERVING DEMO'D LIGHTING TO SERVE NEW LIGHTING AS SHOWN ON
LIGHTING PLAN.
5 UTILIZE EXISTING DATA JACK AND CABLING FOR NEW DATA JACKS / DEVICE SHOWN ON POWER PLAN. DEMO ANY
UNUSED CABLING BACK TO SOURCE.
X
ETR
C C
C C
P
SP
S D
S D
"B"
"A" "J"
ETR
xHP-8
CLASSROOM
ETR
"B"
"B"
"B"
"B" "B"
CL CL
CL CL
HP-7
"B"
"B"
OS
APPROXIMATE LOCATION OF EXISTING
DATA RACK SERVING AREA IN LOWER
LEVEL BELOW. ANY NEW DATA
CABLING SHALL BE TERMINATED ON
EXISTING FVTC-OWNED PATCH PANEL.
RELOCATE TERMINATION OF EXISTING
DATA CABLING FROM CURRENT PATCH
PANEL TO FVTC-OWNED PATCH PANEL.
P
ETR
APPROXIMATE LOCATION
OF EXISTING FACP IN
LOWER LEVEL BELOW.
C6 C6 C6
C6C6C6
C6 C6 C6
C6C6C6
C6C6
ETR
TO
EXISTING
CKT AND
CONTROL
ETR
ETR
"J"ETR CLASSROOM
GENERAL NOTES - POWER
1. CONFIRM EXACT LOCATION OF ALL OUTLETS WITH OWNER PRIOR TO ROUGH-IN.
2. ALL LOW VOLTAGE CABLING IN AREAS WITH EXPOSED STRUCTURE SHALL BE IN CONDUIT.
2/E101
GENERAL NOTES - LIGHTING
1. ALL TYPE C6 FIXTURES SHALL BE FURNISHED BY OWNER.
2. IN ROOMS WITH OCCUPANCY SENSOR, ALL ILLINATION IN ROOM SHALL BE CONTROLLED BY SENSOR UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR TO DETERMINE BEST LOCATION FOR SENSOR IN FIELD WITH
MANUFACTURER. SEE DETAIL .
3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED LIGHT FIXTURES.
1/E101
SLAVE PAK IF NEEDED
(MORE THAN ONE
CIRCUIT CONTROLLED).
POWER
PAK
NEUTRAL
LIGHTING
CIRCUITHOT
3 CONDUCTOR CABLE.
PROVIDE PLENUM RATED
IN PLENUM SPACES.
MOUNT NEXT TO LIGHTING
FIXTURE OUTLET BOX OR
AT PANELBOARD IF CEILING
SPACE NOT ACCESSIBLE.
3 CONDUCTOR CABLE- PLENUM
RATED IF REQUIRED.
TO ROOM
LIGHTING
FIXTURES.
ROOM LIGHTING SWITCHES
AS SHOWN ON FLOOR PLANS.
MOUNT SENSOR DIRECTLY TO
CEILING OR BOTTOM OF
STRUCTURAL MEMBER
SEE PLANS FOR LOCATION
CEILING
CEILING MOUNTED
MOTION SENSOR
ADDITIONAL SENSORS
IN SAME ROOM IF
SHOWN ON PLANS.
GREEN CAT6 CABLE FROM
IVORY JACK TO PATCH PANEL
IN DATA ROOM
CAT6A
JACK
(BLUE)
A LOW VOLTAGE AT PROJECTOR
B LOW VOLTAGE AT INSTRUCTOR'S STATION
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .