IFB_24_25_23_Addedum_2.pdf

PDF 230 KB Posted

Attached to
Groveview Pump Station Improvements State and local contract opportunity
Solicitation number
IFB 24/25-23
Issued by
Seminole County, Florida

About this file

This is Addendum #2 for Invitation for Bid (IFB) 24/25-23 issued by the City of Sanford's Finance Department and Purchasing Division for the Groveview Pump Station #2 Improvements project. The addendum provides clarifications and answers to bidder questions, maintains the original bid response due date of Thursday, June 12, 2025, at 2:00 P.M. Local Time, and addresses several key project details. Significant clarifications include allowing the contractor to use the Tremie/Caisson method for wet well construction, with the contractor responsible for final design and engineering specifications, and guidance on handling a gopher tortoise observed during a site visit.

The estimated project value is $950,000, with bid security requirements ranging from 5-10% of the maximum bid price depending on the total project cost. The addendum provides specific instructions on antenna and tower removal, salvage, and replacement, and introduces a new requirement for a pole and light installation on the northwest corner of the new site. The document emphasizes that all alternative construction methods must be signed and sealed by a Florida-registered Professional Engineer, with specific restrictions on modifying structural dimensions and concrete thicknesses. Contractors are advised to carefully review the detailed technical specifications and follow the precise guidelines for bid submission and project implementation.

View the file

Other files for this state and local contract opportunity

Other files attached to Groveview Pump Station Improvements, newest first.
File Type Posted
800197898_PP_Bond_Form.pdf PDF
IFB_24_25-23_Approved_Agenda.pdf PDF
IFB_24_25-23_Approved_Agenda.pdf PDF
IFB_24_25-23_Grovieview_Pump_Station_Improvement_NOA.pdf PDF
Notice_of_Intent_to_Award.pdf PDF
Notice_of_Intent_to_Award.pdf PDF
Notice_of_Intent_to_Award.pdf PDF
Bid_Tabulation_-_Groveview_Pump_Station_Improvements.pdf PDF
Bid_Tabulation_-_Groveview_Pump_Station_Improvements.pdf PDF
Bid_Tabulation_-_Groveview_Pump_Station_Improvements.pdf PDF
IFB_24_25_23_Bid_Tabulation_UPDATED.pdf PDF
IFB_24_25_23_Bid_Tabulation_UPDATED.pdf PDF
IFB_24_25-23_Tabulation.pdf.pdf PDF
6.12.25_Opening.pdf PDF
6.12.25_Opening.pdf PDF
6.12.25_Opening.pdf PDF
IFB_24_25_23_Adedendum_3.pdf PDF
IFB_24_25_23_Adedendum_3.pdf PDF
IFB_24_25_23_Adedendum_3.pdf PDF
IFB_24_25_23_Adedendum_3.pdf PDF
IFB_24_25_23_Addedum_2.pdf PDF
IFB_24_25_23_Addedum_2.pdf PDF
IFB_24_25_23_Addedum_2.pdf PDF
IFB_24_25_23_Addedum_2.pdf PDF
IFB_24_25_23_Addedum_1.pdf PDF
IFB_24_25_23_Addedum_1.pdf PDF
IFB_24_25_23_Addedum_1.pdf PDF
IFB_24_25_23_Addedum_1.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
Order_ID_7800421.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
Order_ID_7800421.pdf PDF
Order_ID_7800421.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Plans.pdf PDF
IFB_24-25-23_Groveview_Pump_Station_Improvements_-_Project_Manual.pdf PDF
Show all 50

Groveview Pump Station Improvements has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

City of Sanford | Finance Department | Purchasing Division 300 N. Park Avenue Suite 236, Sanford, Florida 32771

Phone: 407-688-5028 or 5030 | Fax: 407-688-5021 | Email: purchasing@sanfordfl.gov ADDENDUM

#2 IFB 24/25-23 GROVEVIEW PUMP STATION

IMPROVEMENTS|

DATE: May 29, 2025

TO: All Bidders/Proposers

FROM: Maria A. Green, Purchasing Coordinator

City of Sanford Purchasing Division

SUBJECT: IFB 24/25-23 GROVEVIEW PUMP STATION IMPROVEMENTS|

ADDENDUM #2

This addendum is issued to provide additional information, clarification, corrections, additions, deletions and/or answers to questions concerning the above referenced solicitation. All information provided in this addendum is incorporated into the solicitation document as set forth therein. All other parts of the solicitation have been maintained as originally distributed. This addendum supersedes any verbal and/or other instructions given to any bidder/proposer qualified to respond pursuant to the requirements set forth in the solicitation document.

I. DUE DATE

This Addendum does not change the solicitation due date. As such, the solicitation response is due no later than Thursday, June 12, 2025, at 2:00 P.M. Local Time.

II. QUESTIONS AND ANSWERS (Q&A)

The City has received the following question(s) concerning the solicitation:

1.) Per Page 14 of the Project Manual see below. Can you advise what the engineer/project estimate is or what percentage the bid bond shall be?

a.) Construction Projects where the Maximum Bid Price is $60,000 or greater:

Bid Security shall be in an amount equal to at least 5% of the Maximum Bid Price (Base Bid Plus Alternates).

b.) Construction Projects where the Maximum Bid Price is less than $60,000:

Bid Security shall be in an amount equal to at least 10% of the Maximum Bid Price (Base Bid Plus Alternates).

Answer: Bid bond to be per project specifications as stated in question. Eng estimates $950,000.

2.) Can the wet well be installed via the tremie method?

Answer: The Contractor may select the Tremie/Caisson method as an alternate to open-cut method for wet well construction. The Contractor is responsible for final design of Tremie/Caisson features to be implemented during construction. The Contractor is also responsible for redesign of features which require modification to facilitate Tremie/Caisson construction. Structural Designs and other engineered items of the Tremie/Caisson including construction specifications shall be mailto:purchasing@sanfordfl.gov

Phone: 407-688-5028 or 5030 | Fax: 407-688-5021 | Email: purchasing@sanfordfl.gov ADDENDUM

#2 IFB 24/25-23 GROVEVIEW PUMP STATION

IMPROVEMENTS|

signed and sealed by a qualified Professional Engineer registered in the State of Florida. The caisson construction alternative applies only to reinforced concrete construction. Revisions to other systems and materials shown in the Contract Documents will not be permitted. Revisions of the structure's internal dimensions will not be permitted. The wall and slab concrete thicknesses shown in the contract documents are minimum and shall not be reduced for alternative designs by the Contractor's Engineer. The Contractor may make increases as required for the Tremie/Caisson construction method. The Tremie/Caisson structure shall be designed to resist buoyancy due to ground water at 100-year flood elevation (EL 45.00). Acceptance of alternative design drawings and specifications is subject to approval by the Owner’s Representative.

3.) During a site visit, a gopher tortoise was observed. Should we include the cost for gopher tortoise relocation in our bid?

Answer: City will review locations of any tortoise burrows and provide direction at time of construction.

4.) Please confirm DUE date, states in bid documents 5/22. (No addendums have been released).

Answer: Due date has been extended to Thursday, June 12, 2025 @ 2pm.

5.) Addendum #1 states the due date is Tuesday, 05/29; however, 05/29 is a Thursday. Would you please clarify this?

Answer: Apologies for the misprint. Due date has been extended to Thursday, June 12, 2025 @ 2pm.

6.) 01270-5 para 2.10 states remove and dispose antenna and tower 01270-8 para 2.22 states new antenna and tower Page E-1 note 4 states remove and coordinate reuse. Are we to provide a new antenna and tower or can we reuse existing?

Answer: Remove and Salvage antenna and tower. Deliver to the City North WRF.

Provide a new antenna and tower per E-2B

7.) 01270-8 para 2.22 states provide and install pole and light, there is no specification for the pole or light, nor is there a proposed location for the light. Page E-3 note states area light not provided due to proximity to residences; is this note being rescinded?

Answer: City would like to include a pole and light on the NW corner of new site powered by manual timer switch. Detail attached.

III. CHANGES, ADDITIONS AND/OR CLARIFICATIONS

Due Date has been changed to Thursday, June 12, 2025, at 2:00 P.M. Local Time.

IV. SIGN-IN SHEET

N/A

Phone: 407-688-5028 or 5030 | Fax: 407-688-5021 | Email: purchasing@sanfordfl.gov ADDENDUM

#2 IFB 24/25-23 GROVEVIEW PUMP STATION

IMPROVEMENTS|

V. ATTACHMENTS

None

Respondents must acknowledge receipt of this Addendum by signing this form below and returning it to the Procurement Division prior to the hour and date specified for receipt of bids/proposals or by including this Addendum with your submittal. Failure to comply may result in disqualification of your response.

Acknowledgment is hereby made of Addendum #2 to IFB 24/25-23 Groveview Pump Station Improvements|

Name of Firm/Company Contact Email

Street Address City, State, Zip Code

Telephone Number Fax Number

Authorized Person Printed Name Authorized Person Title

Authorized Person Signature Date of Signature