i. New RELOC OnePass Splitter Splice – OSS Series (Basis of Design).pdf
PDF 224 KB Posted
- Attached to
- FBI CJIS Division, Lighting Replacement, Bldg 9
- Solicitation number
- 15F06722Q0000043
About this file
This solicitation requests quotes for the replacement of lighting fixtures at the FBI CJIS Division in Clarksburg, West Virginia. The FBI CJIS Division seeks quotes by June 30, 2022 for the purchase of LED lighting fixtures from the attached specifications list or approved equivalents. The replacement fixtures must provide energy efficient lighting and meet the specifications in the attached Excel file. Questions regarding this opportunity are due by June 17, 2022 with quotes due by June 30, 2022 and must be submitted to the specified contracting officer and acquisition support staff. This is an open market solicitation set aside 100% for small business, and the government intends to make a single award based on best value. Delivery is required FOB destination to the FBI CJIS Division facility. Bidders must complete the attached pricing template for evaluation.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OSS_OSU_OST
Catalog Number
Notes Type
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 2017-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/22/19
FEATURES & SPECIFICATIONS
INTENDED USE
The OnePass Splitter Splice (OSS), Switching Tee (OST), and the Selector Unit (OSU) are male/ female devices that can be used in multiple ways for power and lighting applications. The OSS connects to other One Pass system devices and splits the branch circuit wiring into two direc-tions. The OST is located above the primary switch locations and introduces local switching and unswitched power to be used as needed for subsequent fixtures. The OSU provides wiring to fixtures and power devices through a 1/2” trade size knockout.
ELECTRICAL
• Rated for use on 20-amp branch circuits.
• Color-coded labels for quick voltage identification.
• All conductors are 12 AWG copper with -20°C to +90°C thermoplastic insulation rated 600V.
• All components provide a fully rated No. 12 AWG grounding conductor.
• C12S option includes three 12 AWG conductors and 18 AWG shielded pair for controls wir-ing. (-20°C to +90°C)
• Safety-keying prevents accidental mating of components with different voltages.
SYSTEM FEATURES
• EXT option enables OSS’s to be installed in hot and cold applications (-40° to +90°C).
• Type of insulation for EXT option is based on NEC Table 310.104(A).
• Dust Cover available for unused ports: RDC3 METAL DUST COVER CSA/UL J50 (available job pack of 50 only)
• Plenum rated low voltage cable (LVC option).
CONTROLS-ENABLED WIRING OPTIONS
• 0-24V integrated single-circuit or 0-10V low voltage controls applications: select C12S option.
• 0-24V multi-circuit dimming or 0-10V low voltage controls applications: select LVC option.
LISTINGS
• C-UL-US Listed (dry location only).
• C12S option meets NEC requirements for separation of Class 2 and Class 3 circuits from Class 1 circuits by a barrier as defined by Article 725.136(B).
• Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities. (HCF option).
WARRANTY
5-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Actual performance may differ as a result of end-user environment and application.
Specifications subject to change without notice.
OnePass® System Devices
OSS, OSU, OST
OSS
Splitter Splice
OSU
Circuit Selector Unit
OST
Switching Tee
Series Voltage 1 Conductors Controls Wiring Options
OSS 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
12/2G Three 12 AWG conductors, including one 12 AWG ground 2
12/3G Four 12 AWG conductors, including one 12 AWG ground
12/4G Five 12 AWG conductors, including one 12 AWG ground 3
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires 2
LVC 3 position connector system for low voltage wiring 4
2N Two circuit, two neutral 5
EXT Extreme temperature rating conductors 6
IGW Isolated ground wire 7
ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OSS 277 12/4G
Notes
1. 208, 240, 480 voltages not available with 2N option.
2. 12/2G available with C12S only.
3. 12/4G conductors are standard and should be used when options C12S and EXT are not required.
4. See spec sheet LVC for details.
5. 2N only available with 12/4G. Only available with 120, 277, 347 voltages.
6. EXT available with 12/3G only.
7. IGW available with 12/4G conductor and 120V only.
OnePass® System Devices
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 2017-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/22/19
Series Voltage Conductors Controls Wiring Options Connector Type
OSU 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
12/4G Five 12 AWG conductors, including one 12 AWG ground
18/2G Three 18 AWG conductors, including 18 AWG ground 1
18/4G Five 18 AWG conductors, including 18 AWG ground
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires 1
(blank) Not required
2N Two circuit, two neutral 2
IGW Isolated ground wire 3
(blank) Not required
RRL RELOC®-ready luminaires 4
Series Voltage Drop Type Length Controls Wiring Options
OST 120 120V
277 277V
347 347V
1LEVEL Two 12 AWG conductors, plus 12 AWG ground
2LEVEL Four 12 AWG conductors, plus 12 AWG ground
1 ft up to 50 ft (blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires 1
(blank) Not required
N One neutral wire provided in drop
HCF Meets healthcare facility requirements 2
ORDERING INFORMATION For shortest lead times configure product using bolded options.
ORDERING INFORMATION For shortest lead times configure product using bolded options.
Example: OSU 120 12/4G
Example: OST 277 1LEVEL 09
Notes
1. 18/2G available with C12S only.
2. 2N available with 12/4G & 18/4G only.
3. IGW available only with 12/4G conductor and 120V.
4. If RRL selected, fixture must have RRL and wiring instruction. See fixture spec sheet for details. See RRL spec sheet for connector details.
Notes
1. C12S available with 1LEVEL only.
2. HCF available with 2LEVEL drop type only. HCF not available with controls wiring options C12S.
OnePass® System Devices
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 2017-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/22/19
A – 18-gauge galvanized steel cover, zinc alloyed casting
B – Connector body
C – Tin-plated brass contacts
DIMENSIONS
Dimensions are shown in inches (millimeters)
OSS – Splitter Splice
SYSTEM VIEW
System View designs are for illustrative purposes only.
COVER ALL UNUSED “OC2”
PORTS WITH A DUST COVER
“OD” FIXTURE WHIP
ATTACHED TO
LUMINAIRES OR
EMERGENCY UNITS
OC2 OC2
OSS
OCS
OC2 OC
2-1/4 (57.2)
4-9/16 (115.9)
5/8 (15.9)
2-1/4 (57.2)
3-3/8 (85.7)
A
BC
OnePass® System Devices
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 2017-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/22/19
OSU – Selector Unit
DIMENSIONS
Dimensions are shown in inches (millimeters)
A – 18-gauge, zinc-plated, CRS cover B – UL-recognized connector body C – Tin-plated, brass contacts D – .015” spring steel latches E – No. 12 AWG and 18 AWG copper wires with 600V, 90°C thermoplastic insulation
SYSTEM VIEW
System View designs are for illustrative purposes only.
4-5/8 (117.5)
2-3/16 (55.6)
1-7/16 (36.5)
9/16 (14.3)
1-1/16 (27.0)
D
E
A
C
B
OC
OC1
OC1
OSU
OSU
OnePass® System Devices
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 2017-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/22/19
OST
OC1
OC1
OST
OC1
OFC
OFC
SYSTEM VIEW
System View designs are for illustrative purposes only.
DIMENSIONS
Dimensions are shown in inches (millimeters)
A – UL recognized connector body
B – Tin-plated brass contacts
C – No. 12 AWG wire rated at 600V, 90°C
D – Die-cast zinc with zinc-plated CRS cover
E – FMC standard. HCF MC and C12S MC optional
NOTES
• Rated for 20-amp capacity.
4-9/16 (115.9)
2-1/4 (57.2)
2-1/4 (57.2)
3-3/8 (85.7)
5/8 (15.9)
B
C A
D
E
OST – Switching Tee