h. New RELOC OnePass Cables - Fixture Cable – OFC Series (Basis of Design).pdf
PDF 261 KB Posted
- Attached to
- FBI CJIS Division, Lighting Replacement, Bldg 9
- Solicitation number
- 15F06722Q0000043
About this file
This document includes a federal contract opportunity solicitation for lighting replacement and the related product specification sheet. The solicitation requests quotes to purchase LED lighting fixtures from the attached specifications list to replace fixtures at the FBI CJIS Division buildings in Clarksburg, WV. Quotes are due by June 30, 2022 and must include anticipated delivery dates. The set aside is for small businesses only. The specification sheet provides details on various cable products for fixture wiring including OC1, OC2, OC3 cables and fixture cables. It specifies conductor sizes, lengths, voltage ratings, and optional features. Replacement fixtures must meet energy efficiency standards and the specifications in the attached excel sheet.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OFC_OC1_OC2_OC3
Catalog Number
Notes Type
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 1996-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/20/19
FEATURES & SPECIFICATIONS
INTENDED USE
The OnePass Fixture Cable (OFC), Cable 1 port (OC1), Cable 2 port (OC2), and Cable 3 Port (OC3) are male/female cables that provides additional length throughout the RELOC system.
Cables can also provide power to miscellaneous devices such as exits, emergency units, convenience power and access floor systems. The OFC attaches directly into the access plate or through any 1/2” trade-size knockout. The OC2 is a splitter and cable extender in one easy-to-use component. The OC2 All Metal Housings (AMH) provides installers options for how to configure the system based on specification requirements. The OC3 is a splitter and cable extender in one component.
ELECTRICAL
• Rated for use on 20-amp branch circuits.
• Safety-keying prevents accidental mating of components with different voltages.
• C12S option includes three 12 AWG conductors and 18 AWG shielded pair for controls wiring. (-20°C to +90°C).
• The OC2 conductors are 10 AWG or 12 AWG copper conductors with -20°C to +90°C ther-moplastic insulation rated 600V. It includes a fully rated No. 12 AWG & 10 AWG grounding conductor.
• The OC1, OC2 with AMH option, and OC3 are 12 AWG copper with -20°C to +90°C thermo-plastic insulation rated 600V. It includes a fully rated No. 12 AWG grounding conductor.
• The OFC Fixture leads are No. 18 AWG solid copper with prestripped, solid-color leads for easy installation into side, back or push-in-type terminals.
SYSTEM FEATURES
• Pin and socket contacts.
• Color-coded labels for quick voltage identification.
• Available in varying lengths to suit most common fixture spacing requirements.
• Auto-latching springs prevent accidental disengagement.
• Available with green armor standard for easy identification in healthcare facilities (HCF option).
• Dust Cover available for unused ports: RDC3 METAL DUSCT COVER CSA/UL J50 (available job pack of 50 only)
• The OC1, OC2, and OC3 EXT option enables them to be installed in hot and cold applications (-40° to +90°C).
• Type of insulation for EXT option is based on NEC Table 310.104(A).
• Non-plenum rated OC2 plastic housing.
• Plenum rated low voltage cable (LVC option)
OnePass® Cables
OFC, OC1, OC2, OC3
OC1
Cable 1 Port
OC2
Cable 2 Port
OC3
Cable 3 Port
OFC
Fixture Cable
LISTINGS
• C-UL-US Listed (dry location only).
• C12S option meets NEC requirements for separation of Class 2 and Class 3 circuits from Class 1 circuits by a barrier as defined by Article 725.136(B).
• Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities (HCF option).
• Canadian Patent No. 2,845,603 (Class l, Class ll)
WARRANTY
• 5-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Actual performance may differ as a result of end-user environment and application.
Specifications subject to change without notice.
Series Voltage Conductors Length Controls Wiring Options Finish9
OC1 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
12/2G Three 12 AWG conductors, including one 12 AWG ground
12/3G Four 12 AWG conductors, including one 12 AWG ground
12/4G Five 12 AWG conductors, including one 12 AWG ground
1 ft up to 50 ft
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires1
CAT5_ Preterminated and tested CAT5 cable attached, specify length2
LVC 3 position connector system for low voltage wiring3
(blank) Not required
2N Two circuit, two neutral4
EXT Extreme temperature rating conductors5
HCF Meets healthcare facility requirements6
IGW Isolated ground wire7
X Cross Over Cable8
(blank) Not required
RD Red
BK Black
WH White
BE Beige
OJ Orange
ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OC1 277 12/3G 09
6. HCF available with 12/4G conductors only. HCF not available with controls wiring options C12S, CAT5 and LVC.
7. IGW available only with 120V; 12/3G & 12/4G conductor, and up to 35ft length.
8. X option available with 12/3G conductors only. Hot conductors 1 and 2 alternate internally to the cable.
9. Non-plenum rated color cable available up to 35ft.
NOTES
1. C12S must use 12/2G conductors.
2. See spec sheet RCAT5 for details. CAT5 length must be 2FT longer than OC1. When used with OCS, OCU or OD fixture drop, CAT5 length must include the length of the OC1 and the length of drop for the fixture plus 2FT.
3. See spec sheet LVC for details.
4. 2N option available only in 120V, 277V and 347V; 12/4G conductors only
5. EXT option required for EXTREME hot and cold temperature applications (-40° to 90°C). Available with 12/2G and 12/3G conductors.
OnePass® Cables
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 1996-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/20/19
Series Voltage Conductors Length Controls Wiring Options Finish8
OC2 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
10/2G Three 10 AWG conductors, including one 10 AWG ground
10/3G Four 10 AWG conductors, in-cluding one 10 AWG ground
10/4G Five 10 AWG conductors, in-cluding one 10 AWG ground
12/2G Three 12 AWG conductors, including one 12 AWG ground
12/3G Four 12 AWG conductors, including one 12 AWG ground
12/4G Five 12 AWG conductors, including one 12 AWG ground
1 ft up to 50 ft
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires1
CAT5_ Preterminated and tested CAT5 cable attached, specify length2
LVC 3 position connector system for low voltage wiring3
(blank) Not required
2N Two circuit, two neutral4
AMH All metal housings5
EXT Extreme temperature rating conductors6
IGW Isolated ground wire7
(blank) Not required
RD Red
BK Black
WH White
BE Beige
OJ Orange
ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OC2 277 12/4G 25
6. EXT option required for EXTREME hot and cold temperature applications (-40° to 90°C). Available with
10/2G, 10/3G, 12/2G, and 12/3G conductors.
7. IGW available only with 120V; 12/3G & 12/4G conductor, and up to 35ft length.
8. Non-plenum rated color cable available up to 35ft.
NOTES
1. C12S must use 12/2G conductors.
2. See spec sheet RCAT5 for details. When used with OCS, OCU or OD fixture drop, CAT5 length must include the length of the OC2 and the length of drop for the fixture plus 2FT.
3. See spec sheet LVC for details.
4. 2N option available only in 120V, 277V and 347V; 10/4G and 12/4G conductors only.
5. AMH option available with 12/2G, 12/3G, 12/4G conductors.
Series Voltage Conductors Length Controls Wiring Options Finish8
OC3 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
12/2G Three 12 AWG conductors, including one 12 AWG ground
12/3G Four 12 AWG conductors, including one 12 AWG ground
12/4G Five 12 AWG conductors, including one 12 AWG ground
1 ft up to 50 ft
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires1
CAT5_ Preterminated and tested CAT5 cable attached, specify length2
LVC 3 position connector system for low voltage wiring3
(blank) Not required
2N Two circuit, two neutral4
EXT Extreme temperature rating conductors5
HCF Meets healthcare facility requirements6
IGW Isolated ground wire7
(blank) Not required
RD Red
BK Black
WH White
BE Beige
OJ Orange
ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OC3 277 12/3G 15
6. HCF available with 12/4G conductors only. HCF not available with controls wiring options C12S, CAT5 and LVC.
7. IGW available only with 120V; 12/3G & 12/4G conductor, and up to 35ft length.
8. Non-plenum rated color cable available up to 35ft.
NOTES
1. C12S must use 12/2G conductors.
2. See spec sheet RCAT5 for details. When used with OCS, OCU or OD fixture drop, CAT5 length must include the length of the OC3 and the length of drop for the fixture plus 2FT.
3. See spec sheet LVC for details.
4. 2N option available only in 120V, 277V and 347V; 12/4G conductors only
5. EXT option required for EXTREME hot and cold temperature applications (-40° to 90°C). Available with 12/2G, and 12/3G conductors.
OnePass® Cables
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 1996-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/20/19
Series Voltage Conductors Length Controls Wiring Options Connector Type
OFC 120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
12/2G Three 12 AWG conductors, including one 12 AWG ground
12/3G Four 12 AWG conductors, including one 12 AWG ground
12/4G Five 12 AWG conductors, including one 12 AWG ground
1 ft up to 50 ft
(blank) Not required
C12S Integrated CI,CII rated line voltage and signal wires1
CAT5_ Preterminated and tested CAT5 cable attached, specify length2
LVC 3 position connector system for low voltage wiring3
(blank) Not required
G Ground wire4
2N Two circuit, two neutral 5
HCF Meets healthcare facility requirements6
X Cross Over Cable7
(blank) Not required
RRL RELOC®
- ready luminaires8
ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OFC 277 12/3G 11
6. HCF available with 12/4G conductors only. HCF not available with controls wiring options C12S, CAT5 and
LVC. G option required with HCF.
7. X option available with 12/3G conductors only. Hot conductors 1 and 2 alternate internally to the cable.
8. If RRL selected, fixture must have RRL and wiring instruction. See fixture spec sheet for details. See RRL spec sheet for connector details. G option required with RRL.
NOTES
1. C12S must use 12/2G conductors. G option required with C12S.
2. See spec sheet RCAT5 for details. CAT5 length must be 2FT longer than OFC.
3. See spec sheet LVC for details. Mating fixture connection shipped with cable.
4. G option required for use in Canada. Required for C12S, HCF and RRL option.
5. 2N option available only in 120V, 277V and 347V; 12/4G conductors only.
OnePass® Cables
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 1996-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/20/19
DIMENSIONS
Dimensions are shown in inches (millimeters)
A – Die-cast zinc with zinc-plated CRS cover
B – UL recognized connector body
C – Tin-plated brass contacts
D – MC Cable standard. HCF MC, C12S MC optional, IGW option standard with FMC.
2-1/4 (58)
2-3/16 (55.6)
AB
D C
9/16 (14.3)
7/16 (11.1)
3-1/4 (82.6)
3-3/8 (87.5)
3-1/4 (82.6)
4-1/2 (114.3)
1-1/8 (28.6)A
B 7/16 (11.2)
2-1/4 (57.2)
2-1/4 (57.2)
D
C
OC1 - Cable 1 Port
A – Injection-molded, high-impact polymeric compound enclosure
B – Tin-plated, brass contacts
C – MC Cable standard. C12S MC optional, IGW option standard with FMC.
D – 18-gauge galvanized steel cover, zinc alloyed casting
OC2 - Cable 2 Port
2-1/4 (58)
7/16" (11.1)
5/8" (16)
2 1/4 (58)
3 3/8" (87.5)
4 9/16" (116)
A B
C
D
A – Die-cast zinc with zinc-plated CRS cover
B – UL recognized connector body
C – Tin-plated brass contacts
D – MC Cable standard. HCF MC, C12S MC optional, IGW option standard with FMC.
OC3 - Cable 3 Port
OnePass® Cables
One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com
© 1996-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 06/20/19
A – UL-recognized connector body
B – Die-cast zinc with zinc-plated CRS cover
C – Tin-plated, brass contacts
D – Cast snap-in fitting fits 1.2” trade-size K.O. and provides grounding
E – No. 18 AWG solid copper wires rated at 600V, 90°C thermoplastic insulation with stripped leads
F – MC cable standard. HCF MC, C12S MC optional.
NOTES
• One, two or three hot conductors in 120V and 277V as required.
• Rated for 20-amp capacity.
• Prefabricated standard selector cable carrying No. 12 AWG copper conductors. 600V, 90°C thermoplastic insulation and fully rated bare grounding conductor.
• Standard selector cable provides auto-grounding to fixture unless specified otherwise.
B
F
C D
A
2-1/4 (58)
2-3/16 (55.6)
7/16 (11.1)
9/16 (14.3)
1-1/4 (31.8)
3-3/8 (87.5)
3-1/4 (82.6)
E
E
DIMENSIONS
Dimensions are shown in inches (millimeters)
OFC - Fixture Cable
SYSTEM VIEW
System View designs are for illustrative purposes only.
OC1
OFC
OFC
OC
OST
OnePass OFC Wire Color Chart 120V, 277V, 347V Standard Wire Colors
Position 1 2 3 4 5
Conductor Ground Hot #1 Hot #2 Hot #3 Neutral #1
120V & 347V Bare or Green Black Red Blue White
277V Bare or Green Brown Orange Yellow Gray
208V, 240V, 480V Standard Wire Colors
Position 1 2 3 4 5
Conductor Ground Hot #1 Hot #2 Hot #3 Hot #4
208V & 240V Bare or Green Black Red Blue Violet
480V Bare or Green Brown Orange Yellow Violet
120V, 277V, 347V Two Circuit, Two Neutral (2N option)
Position 1 2 3 4 5
Conductor Ground Hot #1 Hot #2 Neutral #2 Neutral #1
120V & 347V Bare or Green Black Red Gray White
277V Bare or Green Brown Orange White Gray
120V, 277V, 347V Class I, Class II (C12S option)
Position 1 2 3 4 5
Conductor Hot #1 Neutral #1 Ground Data #1 Data #2
120V & 347V Black White Bare or Green Violet Gray
277V Brown Gray Bare or Green Violet Gray
208V & 240V Brown Orange Bare or Green Violet Gray
480V Brown Orange Bare or Green Violet Gray
Note: Wire colors are specific for cables with exposed wireleads.
File details come from the government source that posted it. Updated .