HU000126QE041 Bottle Filling Station Questions and Answers.pdf

PDF 122 KB Posted

Attached to
Bottle Filling Station with Acidifier
Solicitation number
HU000126QE041
Issued by

About this file

This is a Questions and Answers document for federal contract opportunity HU000126QE041 issued by the Uniformed Services University.

The procurement is for a brand new bottle filling station with acidifier capability. The system must fill domestic water with 2n Hydrochloric acid at a rate of 24 bottles per minute into two bottle sizes: rat bottles of 300 mls and mouse bottles of 250 mls. No capping or labeling capabilities are required. Delivery must be made to the Uniformed Services University, Logistics Division, 4301 Jones Bridge Road, Bethesda, MD 20814-4712. A significant amendment to the RFQ removed installation services from the scope of work; consequently, questions regarding site visits, existing station removal, plumbing requirements, installation area dimensions, electrical power sources, and site diagrams were all answered with clarification that installation services are no longer being requested and the RFQ has been amended to reflect this change. The procurement focuses solely on the delivery of the bottle filling station equipment itself rather than installation or site preparation activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HU000126QE041 Questions and Answers

1. We would like to know if this is a brand new contract OR if there is (was) an incumbent performing these services. If not brand new, could you please provide the current / previous contract number?

Answer: This will be a brand new contract.

2. Could you please confirm the correct shipping address to be used for this procurement?

Answer: The Uniformed Services University, Logistics Division, 4301 Jones Bridge Road, Bethesda, MD 20814-4712

3. What is the viscosity of the product/fluid to be filled?

Answer: domestic water with 2n Hydrochloric acid

4. What is the required or target filling rate in bottles per minute?

Answer: 24 bottles

5. What bottle volume or range of bottle volumes will the system be required to fill?

Answer: Rat 300 mls and mouse 250 mls

6. Are any capping and/or labeling capabilities required as part of the system?

Answer: No.

7. Will there be a site visit scheduled to view the current location where the bottle filling station will be installed?

Answer: A site visit will not be scheduled. Installation services are no longer being requested. The RFQ has been amended to reflect this change.

8. If no site visit is scheduled, is there an existing bottle filling station in the space where the new system will be installed?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

9. If an existing station is present, will the contractor be responsible for removing it?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

10. Can the plumber utilize the existing water lines/rough-in, or will it require the installation of new plumbing and capping off existing water lines?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

11. What are the dimensions or measurements of the installation area?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

12. Is there currently an active electrical power source at the installation location?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

13. Are there pictures or site diagrams available for review?

Answer: Installation services are no longer being requested. The RFQ has been amended to reflect this change.

14. Could you please confirm the complete physical delivery/shipping address for the required Bottle Filling Station with Acidifier?

Answer: The Uniformed Services University, Logistics Division, 4301 Jones Bridge Road, Bethesda, MD 20814-4712. This is the same answer of question #2.