Report1
| LABORATORY ANALYSIS REPORT | ESIS Environmental Health Laboratory |
| 100 Sebethe Drive, Suite A-5 | |
| Cromwell, CT 06416 | |
| (860) 635-6475 or (800) 243-4903 |
| To: | Bryan Goff | Report #: | C1343931 | |
| US Coast Guard Academy | ||||
| 15 Mohegan Ave | P.O. No.: | |||
| New London, CT 06320 | Base General - Various Roofs | |||
| Date Received: | 5/1/13 | |||
| Date Analyzed: | 5/6/13 | |||
| Date Reported: | 5/6/13 | (Page 1 of 1) |
| Analysis: Asbestos Identification |
| Analytical Method: Polarized Light Microscopy with dispersion staining at 100x Magnification; NIOSH 9002, Issue 2 |
| Sample Number | Color | Analytical Identification | % Detected |
| B-NE-S | *Black/Silver | Chrysotile Asbestos | 5 |
| H-EW | *Black/Silver/Yellow | Chrysotile Asbestos | 15 |
| MAC-SE | *Black/Grey/White | Chrysotile Asbestos | 10 |
| C-WR | *Black/Grey/Brown | Chrysotile Asbestos | 5 |
| B-WW | Black | No Asbestos Detected | <1 |
| W-L | *Black/Grey/Brown | No Asbestos Detected | <1 |
| W-M | *Black/Grey/Tan | No Asbestos Detected | <1 |
| Y-WM | *Black/Yellow | Chrysotile Asbestos | Trace, <1 |
| C-CS | *Black/White/Brown | No Asbestos Detected | <1 |
| WL | *Black/Silver/Tan | No Asbestos Detected | <1 |
| JE | *Black/Yellow | No Asbestos Detected | <1 |
| JW | *Black/Yellow | No Asbestos Detected | <1 |
| MLM | *Black/Silver/Tan | No Asbestos Detected | <1 |
| Mac C | *Black/Brown/Yellow | No Asbestos Detected | <1 |
| Mac NE | *Black/Brown/Yellow | No Asbestos Detected | <1 |
| Mac PL | *Black/Brown | No Asbestos Detected | <1 |
Samples were homogeneous unless indicated otherwise above by an asterisk (* = Non-Homogeneous)
| Fine fibers (<0.1 um in diameter) cannot be resolved by PLM. Samples containing such fibers (eg: paint, vinyl tiles) can produce a false negative result. |
| Confirmation can be accomplished by using TEM or SEM analyses. |
Percentages given are visual estimates based on surface area.
Unless noted, the condition of samples on receipt was acceptable. Results relate only to items tested in the condition received.
Approved By: James Kenny James Kenny CIH, CSP - Laboratory Manager Date: 5/6/13