Text version

Report1

LABORATORY ANALYSIS REPORTESIS Environmental Health Laboratory
100 Sebethe Drive, Suite A-5
Cromwell, CT 06416
(860) 635-6475 or (800) 243-4903
To:Bryan GoffReport #:C1343931
US Coast Guard Academy
15 Mohegan AveP.O. No.:
New London, CT 06320Base General - Various Roofs
Date Received:5/1/13
Date Analyzed:5/6/13
Date Reported:5/6/13(Page 1 of 1)
Analysis: Asbestos Identification
Analytical Method: Polarized Light Microscopy with dispersion staining at 100x Magnification; NIOSH 9002, Issue 2
Sample NumberColorAnalytical Identification% Detected
B-NE-S*Black/SilverChrysotile Asbestos5
H-EW*Black/Silver/YellowChrysotile Asbestos15
MAC-SE*Black/Grey/WhiteChrysotile Asbestos10
C-WR*Black/Grey/BrownChrysotile Asbestos5
B-WWBlackNo Asbestos Detected<1
W-L*Black/Grey/BrownNo Asbestos Detected<1
W-M*Black/Grey/TanNo Asbestos Detected<1
Y-WM*Black/YellowChrysotile AsbestosTrace, <1
C-CS*Black/White/BrownNo Asbestos Detected<1
WL*Black/Silver/TanNo Asbestos Detected<1
JE*Black/YellowNo Asbestos Detected<1
JW*Black/YellowNo Asbestos Detected<1
MLM*Black/Silver/TanNo Asbestos Detected<1
Mac C*Black/Brown/YellowNo Asbestos Detected<1
Mac NE*Black/Brown/YellowNo Asbestos Detected<1
Mac PL*Black/BrownNo Asbestos Detected<1

Samples were homogeneous unless indicated otherwise above by an asterisk (* = Non-Homogeneous)

Fine fibers (<0.1 um in diameter) cannot be resolved by PLM. Samples containing such fibers (eg: paint, vinyl tiles) can produce a false negative result.
Confirmation can be accomplished by using TEM or SEM analyses.

Percentages given are visual estimates based on surface area.

Unless noted, the condition of samples on receipt was acceptable. Results relate only to items tested in the condition received.

Approved By: James Kenny James Kenny CIH, CSP - Laboratory Manager Date: 5/6/13