Attachment_1_Schedule_of_Supplies_and_Services_FIR_DD_08DEC2016.xls

XLS spreadsheet 42 KB Posted

Attached to
USCGC FIR FY2017 DRYDOCK REPAIRS
Solicitation number
HSCG85-17-Q-P45024
Issued by

About this file

Attachment 1- Schedule of Supplies and Services

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOS&S

PRICING SCHEDULE FOR:
USCGC FIR (WLB-225B) DRYDOCK AVAILABILITY FY2017
ITEMDESCRIPTIONUNIT PRICEUNITQTYEXTENDED PRICE
D-001Hull Plating (U/W Body), InspectJOB1
D-002Hull Plating (U/W Body), Ultrasonic TestingJOB1
D-003Appendages (U/W), Leak TestJOB1
D-004Propulsion Shaft Fairwaters and Rope Guards, InspectJOB1
O-005Appendages (U/W) - Internal, PreserveJOB1
O-006Chain Locker(s), Clean and InspectJOB1
D-007Voids (Non-Accessible), Leak TestJOB1
O-008Voids (Non-Accessible), Internal Surfaces, PreserveJOB1
D-009Tanks (Ballast), Clean and InspectJOB1
O-010Propulsion Shaft Seals, Mechanical Overhaul And Inflatable RenewalJOB1
D-011Controllable Pitch Propeller, System MaintenanceJOB1
D-012Controllable Pitch Propeller Hub, General Maintenance, PerformJOB1
O-013Controllable Pitch Propeller Hub, Remove and ReinstallJOB1
D-014Main Diesel Engine (MDE) Exhaust Piping, Commercial CleanJOB1
D-015Ship Service Diesel Generator (SSDG) Exhaust Piping, Commercial CleanJOB1
D-016Circuit Breakers (60 Hz), Inspect and TestJOB1
D-017Fathometer Transducer (Deep Water), General MaintenanceJOB1
D-018Underwater (Speed) Log Transducer(s), RenewJOB1
D-019Vent Ducts (Engine And Motor Room All), Commercial CleaningJOB1
D-020Vent Ducts (Galley and Pantry Room All), Commercial CleaningJOB1
D-021Vent Ducts (Laundry Exhaust), Commercial CleaningJOB1
D-022Vent Ducts (All Other), Commercial CleaningJOB1
D-023Sea Valves and Waster Pieces, Overhaul or RenewJOB1
D-024Sea Strainers - Simplex (All Sizes), Clean and InspectJOB1
D-025Sea Bay, Preserve 100%JOB1
D-026Rudder(s), Preserve (“100%”)JOB1
D-027Rudder and Rudder Stock, Remove and InspectJOB1
D-028Thruster Units (Bow And Stern), OverhaulJOB1
D-029Hull Fittings (Weight Handling Rigging Hardware), Inspect and TestJOB1
D-030Anchor Windlass, Inspect and ServiceJOB1
D-031Towing Bitts, Chocks, and Fairleads, Inspect and TestJOB1
D-032Single Point Davit - RHIB, OverhaulJOB1
D-033Twin Pivot Arm Davit, OverhaulJOB1
D-034Commissary Hoist, Inspect and ServiceJOB1
D-035Grey Water Holding Tank(s), Clean and InspectJOB1
D-036Sewage Holding Tank(s), Clean and InspectJOB1
D-037Grey Water Piping, Clean and FlushJOB1
D-038Sewage Piping, Clean And FlushJOB1
O-039Buoy Cargo Hold Deck, Preserve 100%JOB1
O-040Tanks (Ballast), Preserve “100%”JOB1
O-041Tanks (Ballast), Preserve “Partial”JOB1
D-042Fathometer Transducer (Shallow Water), RenewJOB1
D-043U/W Body, Preserve (100%)JOB1
D-044Superstructure, Preserve “Partial”JOB1
D-045Cathodic Protection / Zinc Anodes, RenewJOB1
D-046Impressed Current Cathodic Protection System, Inspect and MaintainJOB1
O-047Impressed Current Cathodic Protection System Anodes, RenewJOB1
O-048Impressed Current Cathodic Protection System Reference Cells, RenewJOB1
D-049Impressed Current Cathodic Protection System Dielectric Shield (Capastic Fairing), RenewJOB1
D-050DrydockJOB1
D-051Temporary Services, Provide - CutterJOB1
O-052Temporary Messing, ProvideJOB1
O-053Temporary Berthing, ProvideJOB1
D-054Sea Trial Performance, Support, ProvideJOB1
O-055Bilges, PreserveJOB1
O-056SSDG Isolation Mount, RenewJOB1
O-057SSDG Heat Exchanger, ModifyJOB1
O-058Buoy Deck Equipment Emergency Brake Release Hand Pump, ModifyJOB1
O-059Main Diesel Engine, Mount UpgradeJOB1
D-060Sea Strainers - Duplex (All Sizes), OverhaulJOB1
O-061Stern Tube Interior Surfaces, Preserve 100%JOB1
D-062Firemain Valves, Overhaul or RenewJOB1
O-063Deck Covering (Interior Wet/Dry), RenewJOB1
D-064Anchor Windlass Foundation RenewJOB1
D-065Bow Thruster Tunnel, RepairJOB1
O-066Stack Lighting, InstallJOB1
D-067Crane Pedestal Stuffing Tubes, Renew.JOB1
O-068Crane Pedestal Internal, PreserveJOB1
O-069Compartment Insulation (Various Locations), RenewJOB1
D-070Vent Duct Systems, RepairJOB1
O-071Quick-Acting Watertight Doors (QAWTD) Panels, RenewJOB1
D-072Hydraulic Cargo Hold Hatch (1-35-0) and Manual SORS Cargo Hold Hatch (1-41-0), ServiceJOB1
O-073Seawater Heat Exchangers; Clean, Inspect And HydrotestJOB1
D-074Bridge Window Weatherstripping, RenewJOB1
O-075Buoy Padeyes, RenewJOB1
D-076Propulsion Shafting; Remove, Inspect, and ReinstallJOB1
D-077Decks – Exterior (Buoy or Construction Deck), Preserve 100%JOB1
D-078Hull Plating Freeboard (Buoy Port Areas), PreserveJOB1
D-079Hull Plating Freeboard, Preserve “100%”JOB1
D-080Thruster Fairing Covers, RenewJOB1
O-00AComposite Labor RateHour3450
O-00ZLaydaysDay5
Total Price of Definite Items
Total Price of Option Items
Total Price of Definite and Optional Items

&C(9/17/2016) Draft-4 - Page &P of &N