Text version

Questions:

1. Are there any height restrictions for the cabinets?

a. There are no height restrictions.

2. CLIN0004 and 0005 both call for quantity 2, but there is only one location and one frequency for each one. Is the requirement really for 2 identical redundant transmitter configurations for each CLIN?

a. The quantity is correct. There are 2 identical systems that will operate on 2 separate frequencies.

3. Several of the descriptions (e.g. CLIN0006) include both an output power level (e.g. 300W) and an output power range (e.g. 300W-1KW). In these situations, do you want a transmitter that is capable of output power across the whole range, or one capable of at least the specified level?

a. We need transmitters that are capable of output power across the whole range. The output power needs to be linearly adjustable from a minimum power rating of 30% of the maximum to the maximum power rating specified in each CLIN (e.g. 300-100KW).