Questions and Answers
Question #1) All of the specifications call for a remote control unit that is "GSM (cellular) Modem Compatible". - Please provide the make and model of cellular modem, that you have, or the type on interface available on the modems, for the remote to connect to, so that we can confirm compatibility.
Answer: In the case of Europe's remote control system, the GSM Modems are private label devices and were purchased directly from Telecom Italia. They use RS-232 for control. DB9 to DB9. The PC that is used to control uses a PCMCIA card to dial out. All of the current GSM systems there were integrated into the XMTR systems by BE (except Verona) when they were purchased. (BE provided information on how to integrate the BURK system into the XMTR's @ Verona.)
Question #2) Please confirm that all items, and all CLIN are to ship to the Central Receiving Point at Ft Belvoir, VA 22060
Answer: Yes, all items for this project are to be shipped to the Central Receiving Point at Ft. Belvoir, VA 22060
Question #3: In reference to the above solicitation, all of the line items specify rack cabinet(s). How many rack cabinets are specified per system?
Is this at the discretion of the vendor?
Answer: Yes, the vendor may quote as many racks as the vendor determines necessary to rack the Main/Alternate equipment configuration. i.e. if the transmitter takes up more than one rack then they need to quote more than one rack for the transmitter.
Question #4: Can you confirm that the required efficiency of the high power FM transmitters (CLIN0001, CLIN0002, CLIN0003) is 50% but the low power FM transmitters (CLIN0004, CLIN0005, CLIN0006, and CLIN0007) is 60% and that this is not an error?
Answer: This is not an Error, these are the minimum efficiency specifications that must be met or exceeded.
Question #5: Should the transmitters be created for international shipment, or do they just need to ship strapped onto pallets?
Answer: Yes, The transmitters should be crated for international shipment.