ITEM NO

SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK YSN - 5KW, FM

FFP

Two 5KW FM transmitters in Main/Alternate configuration. - See Table 1 CLIN Specifications for detailed requirements.

FOB: Destination

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNE ROTA - 5KW, FM, 102.5MHZ

Two 5KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNE VICENZA - 5KW, FM, 106.0 or 107.0 MHZ

Two 5KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
2
Each

AFNE KATTERBACH - 1KW, FM

Two 1KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
2
Each

AFNK DGU - 1KW, FM, 88.5MHz

Two 1KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFN BORINQUEN - 300W, FM, 90.5MHz

Two 300W - 1KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFN BORINQUEN - 300W, FM, 91.1MHz

Two 300W - 1KW FM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK CSY - 100W, FM, 88.5MHz

Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK CONCORD - 100W, FM, 88.5MHz

Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK OSN - 50W, FM, 88.5MHz

50W - 300W FM Digital transmitters/exciters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK DGU - 5KW, AM, 1080KHz

5KW AM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNE SPG - 1KW, AM, 1143KHz

Two 1KW AM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK CSY - 1KW, AM, 1197KHz

Two 1KW AM transmitters in Main/Alternate configuration - See Table 1 CLIN Specifications for detailed requirements.

ITEM NO
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1
Each

AFNK CSY - 250W, AM, 1161KHz

Two 250W - 1KW AM transmitters in Main/Alternate configuration - Table 1 CLIN Specifications for comple required specifications

SPECIFICATIONS TABLE 1

TABLE 1 CLIN SPECIFICATIONS

All 14 Systems supplied shall be from one manufacturer to ensure continuity in support, training, and maintenance.

CLIN0001 - 5000W FM Transmitter System salient characteristics:

1. Two 5KW FM transmitters in Main/Alternate configuration.

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, and IEC 215 safety requirements

8. Analog, composite, and AES inputs.

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

9. Stereo generator.

10. IP Connectivity

11. Front Panel Control and Metering

12. Automatic transmitter switcher.

13. RF switch.

14. Low Pass Filter

15. Rack cabinets

16. Load resistor

17. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 1 each Frequency: 102.7MHz

CLIN0003 - 5000W FM Transmitter System salient characteristics:

1. Two 5KW FM transmitters in Main/Alternate configuration.

2. AC Input Voltage: 240VAC, 50/60Hz, 3-Phase D

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions.

9. Analog, composite, and AES inputs.

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator.

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher.

14. RF switch.

15. Low Pass Filter

16. Rack cabinets

17. Load resistor

18. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 1 each Frequencies: 106.0 MHz CLIN0002 - 5000W FM Transmitter System salient characteristics:

1. Two 5KW FM transmitters in Main/Alternate configuration.

2. AC Input Voltage: 208VAC, 60Hz, 3-Phase Y.

3. Efficiency: 50% or better.

4. Power Factor: 0.90 or better.

5. Output Impedance: 50 ohms.

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements.

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions.

9. Analog, composite, and AES inputs.

a. AES Impedance: 110 Ohm balanced.

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced.

10. Stereo generator.

11. IP Connectivity

12. Front Panel Control and Metering.

13. Automatic transmitter switcher.

14. RF switch.

15. Low Pass Filter.

16. Rack cabinets.

17. Load resistor.

18. Remote Control Unit that is GSM (cellular) Modem Compatible.

Requirement: 1 each Frequencies: 102.5MHz

CLIN0004 and CLIN0005 - 1000W FM Transmitter System salient characteristics:

1. Two 1KW FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions.

9. Analog, composite, and AES inputs.

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator.

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher.

14. RF switch.

15. Low Pass Filter

16. Rack cabinets

17. Load resistor

18. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 2 each Frequencies: CLIN0005 -107.3MHz CLIN0004 - 88.5MHz

CLINS 0006 and 0007 - 300W FM Transmitter System salient characteristics:

1. Two 300W - 1KW FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Analog, composite, and AES inputs.

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

9. Stereo generator.

10. IP Connectivity

11. Front Panel Control and Metering

12. Automatic transmitter switcher.

13. RF switch.

14. Low Pass Filter

15. Rack cabinets

16. Load resistor

17. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 2 each Frequencies: 90.5MHz CLIN0006 91.1MHz CLIN0007

CLIN0008 and CLIN0009 100W FM Transmitter System salient characteristics:

1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration

2. AC Input Voltage: 110/240VAC, 50/60Hz, Single-Phase

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator.

9. Front Panel Control

10. Automatic transmitter switcher.

11. RF switch.

12. RF output Low Pass Filter

13. Rack cabinets

14. Load resistor

15. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 2 each Frequencies: 88.5MHz CLIN0008 88.5MHz CLIN0009

CLIN0010 - 50W FM Transmitter System salient characteristics:

16. Two 50W - 300W FM Digital transmitters/exciters in Main/Alternate configuration

17. AC Input Voltage: 110/240VAC, 50/60Hz, Single-Phase

18. Power Factor: 0.90 or better

19. Output Impedance: 50 ohms

20. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

21. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

22. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

23. Stereo generator.

24. Front Panel Control

25. Automatic transmitter switcher.

26. RF switch.

27. RF output Low Pass Filter

28. Rack cabinets

29. Load resistor

30. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 1 each Frequency: 88.5MHz CLIN0010

CLIN0011 - 5000W AM Transmitter System salient characteristics:

1. Two 5KW AM transmitters in Main/Alternate configuration

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 75% or better

4. Power Factor: 0.80 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Analog, composite

a. Impedance: 600 Ohm Balanced

10. Automatic transmitter switcher.

11. Front Panel Metering

12. RF switch.

13. Rack cabinets

14. Load resistor

15. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 1 each Frequency: 1080KHz CLIN0011

CLIN0012 and CLIN0013 1000W AM Transmitter System salient characteristics:

1. Two 1KW AM transmitters in Main/Alternate configuration

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions.

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher.

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

15. Load resistor

16. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 2 each Frequencies: 1197KHz CLIN0013 1143KHz CLIN0012

CLIN0014 - 250W AM Transmitter System salient characteristics:

1. Two 250W - 1KW AM transmitters in Main/Alternate configuration

2. AC Input Voltage: 240VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Analog, composite

a. Impedance: 600 Ohm Balanced

10. Automatic transmitter switcher.

11. Front Panel Metering

12. RF switch.

13. Rack cabinets

14. Load resistor

15. Remote Control Unit that is GSM (cellular) Modem Compatible Requirement: 1 each Frequency: 1161KHz CLIN0014

END OF TABLE 1 CLIN SPECIFICATIONS

DELIVERY INFORMATION

CLIN
DELIVERY DATE
QUANTITY
SHIP TO ADDRESS
UIC
0001
120 dys. ADC
1
HQ0516 DEFENSE MEDIA ACTIVITY

AL SOLIS

CENTRAL RECEIVING POINT

5921 16TH STREET BLDG 190

FT BELVOIR VA 22060

301-222-6567

HQ0516