This is a final architectural drawing for the Howlett Building door replacement project prepared by Evan Lloyd Associates, Inc. for the Illinois Secretary of State (ILSOS). The project involves the replacement of two sets of double doors at the Howlett Building's 2nd Street dock entrance located at 501 South 2nd Street, Springfield, Illinois. The scope of work includes removing existing steel doors and frames, installing new 12-gauge welded steel doors with galvanized and field-painted finishes, and installing associated hardware and electronic access control systems. Two door configurations are specified: Set 101 consists of two 3'-8" x 8'-0" x 1¾" steel doors, and Set 102 consists of two 3'-10" x 8'-0" x 1¾" steel doors. Hardware requirements include continuous hinges, exit devices with mortise levers and electronic strikes, weatherstripping, door sweeps, thresholds, closers with hold-open features, kick plates, flush bolts, wall stops, and silencers. Additional work includes salvaging and reinstalling existing louvers, reconnecting a salvaged security camera, removing and reinstalling scramble pads and badge readers, and extending low-voltage control wiring to accommodate the new electronic locking systems.
The drawings specify Grade 1 ASTM A1011/A1011M steel doors with continuous steel truss core design and insulation, with finish requirements of primer, intermediate coat in semi-gloss, and top coat in semi-gloss. Detailed specifications identify approved manufacturers for all hardware components, including Ives hinges and flush bolts, Hagar pulls and kick plates, National Guard Products weatherstripping and sweeps, Sargent exit devices, and Norton door closers and electronic controls. The contract documents indicate that pre-approved equal products will be considered. All seams and joints require sealant application, and touch-up painting of adjoining plaster and finishes is required as needed. Electrical work includes connecting door closers to a new circuit in an existing 120-volt panel and extending low-voltage control wiring below grade with conduit protection. The project drawings bear a date of December 6, 2025, with an expiration date of November 30, 2026, and were drawn by Timothy B. Smith under Project No. 25057.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Howlett Dock Door RFQ - Rebid 26PS749012.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
J
J
8' -0
2"
2'- 2"
7'-11"±
8"
2'- 6"
6"
312"
8' -0
8'-2"±
2'-0"
2'- 6"
11"
3"
2"
4"
3"
2"
2"
4"
312"
2"
A-1
BAB
© Evan Lloyd Associates, Inc.
TC
S
E
CRADE
IO
N
AT
TIMOTHY
B. SMITH
L
SN
E
IC
S
TIH
F
TE
O ILIL
001-017445
Date:
Drawn By:
Revised:
Revised:
Project No.
SHEET
OF SHEET
Date Signed:
Expiration Date:
S ou th Si xth S tre et
Sp rin gfi eld
, Il lin ois
Ph on e
7.7
.70
NE
W
D
OO
RS
HO
W
LE
TT
B
UI
LD
IN
G
1 S
OU
TH
2N
D
ST
RE
ET
SP
RI
NG
FI
LE
D, IL
LIN
OI
S
DEC. 6, 2025
25057
DEC. 6, 2025
NOV. 30, 2026101
101 102
SIZE
DOORDOOR
NO. SET
HRDW.
TYPE
FRAME
DOOR SCHEDULE
MAT'L.TYPE FINISH FINISHMAT'L. JAMBHEAD
101 STEEL PAINTSTEELPAINT(2) 3'-8" x 8'-0" x 1 34"
102 PAINTSTEELBPAINT 2(2) 3'-10" x 8'-0"± x 1 34"
FLUSH 14/A-1 5/A-1
6/A-1 7/A-1
SET NO. 1
CONTINUOUS HINGES
EXIT DEVICE W/ MORTISE LEVERSET
- ENTRANCE FUNCTION & ELECTRONIC STRIKE
WEATHERSTRIPPING
DOOR SWEEPS
THRESHOLD
CLOSERS W/ HOLD-OPEN
KICK PLATES (42"W x 34"H)
FLUSH BOLTS
DUST-PROOF STRIKE
WALL STOPS
SILENCERS
ASTRAGAL PLATE
SET NO. 2
CONTINUOUS HINGES
PUSH PLATE
DOOR PULL
CLOSERS W/ HOLD OPEN
KICK PLATES (42"W x 34"H)
WALL STOPS
SILENCERS
SCALE: 14" = 1'-0"
NEW PARTIAL PLAN1
SCALE: 12" = 1'-0"
FRAME TYPE A2 SCALE: 12" = 1'-0"
FRAME TYPE B3
SCALE: 112" = 1'-0"
HEAD DETAIL4
SCALE: 112" = 1'-0"
HEAD DETAIL6
SCALE: 112" = 1'-0"
JAMB DETAIL7
SCALE: 112" = 1'-0"
JAMB DETAIL5
12 GA WELDED STEEL
DOOR FRAME -
GALV./ FIELD PAINT
SOLID TRANSOM PANEL - PAINT
LIMESTONE STRUCTURE
REINSTALL SALVAGED
LOUVER & PAINT
EXIST. DUCT
12 GA WELDED STEEL
DOOR & FRAME -
GALV./FIELD PAINT
12 GA WELDED STEEL
DOOR & FRAME -
GALV./FIELD PAINT
12 GA WELDED STEEL
DOOR & FRAME - SHOP
PRIME/FIELD PAINT
12 GA WELDED STEEL
DOOR & FRAME - SHOP
PRIME/FIELD PAINT
EXIST. MASONRY
STRUCTURE
EXIST. WOOD BLOCK
EXIST.BRICK
WAINSCOTTING
EXIST. MASONRY
STRUCTURE
EXIST. PLASTER
CAULK
EXISTING LIMESTONE
CUTOUT FOR 12"±X24"± DUCT
EXIST. DUCT TO REMAIN
NOTES:
1. FINISH TO BE PAINT (PRIMER, INTERMEDIATE COAT (SEMI-GLOSS), TOP COAT (SEMI-GLOSS).
2. APPLY SEALANT TO ALL SEAMS AND JOINTS.
3. TOUCH-UP ADJOINING PLASTER AND PAINT AS NEEDED.
4. COORDINATE CONNECTION OF SCRAMBLE PAD WITH SECRETARY OF STATE.
5. DOORS SHALL BE GRADE 1, ASTM A1011/A1011M CS TYPE B, FULLY STIFFENED W/ CONT. STEEL
TRUSS DESIGN CORE MATERIAL & SPACES INSULATED.
6. FULL LENGTH HINGE: IVES 112HD
7. PULLS: HAGAR 35N 4"X16"
8. PUSH PLATES: HAGAR 30S 4"X16"
9. KICK PLATES: HAGAR 037815
10. THRESHOLDS: HEAVY DUTY, 11 GA. STAINLESS STEEL, SADDLE 5” WIDE X 1/2'” TALL X LENGTH
REQUIRED TO FIT OPENING.
11. DOOR BOTTOM SWEEP: NATIONAL GUARD PRODUCTS 320NA
12. HEAVY DUTY FLUSH BOLT: IVES 262
13. WALL STOP: HAGAR 230W
14. EXIT DEVICE: SARGENT 56-8900 SERIES WITH 700 SERIES ET ENTRANCE MORTISE LEVERSET
TO ACCEPT STATE OF ILLINOIS PROVIDED CORE
15. WEATHERSTRIPPING: NATIONAL GUARD PRODUCTS 156VA
16. CLOSERS: NORTON D6021
17. SWITCH POST: NORTON 500
18. FRAME SWITCH: NORTON 503
19. WALL SWITCH: NORTON 502
20. PRE-APPROVED EQUAL PRODUCTS WILL BE CONSIDERED
RE-INSTALL POST MOUNTED SCRAMBLE
PAD & BADGE READER. RECONNECT TO
NEW ELECTRONIC LOCKS.
WITH LITE
HALF
LITE
NO
RT
H
INSULATED STEEL
TRANSOM PANEL
(PAINT)
INSUL.
REMARKS
A-1
A-1
A-1
A-1
CAULK
CAULK
GROUT & BACK-PRIME FRAME. GROUT NOT REQUIRED AT HEAD.
GROUT & BACK-PRIME FRAME. GROUT NOT REQUIRED AT HEAD.
EXIST. PLASTER
EXIST. PLASTER
SCALE: 14" = 1'-0"
DEMOLITION PLAN
NO
RT
H
NORTH
WORK AREA
REMOVE EXISTING STEEL
DOOR AND FRAME
REMOVE EXISTING STEEL DOOR
AND FRAME. SALVAGE CAMERA.
DUCTWORK AT CEILING TO
REMAIN. PROTECT AND
SUPPORT DURING
CONSTRUCTION.
WELDED
A
WELDED
1" INSUL. CLEAR,
TEMPERED GLASS
14" CLEAR,
TEMPERED
GLASS
RE-CONNECT
SALVAGED CAMERA
ON EXTERIOR FACE
SCALE: N.T.S.
KEY PLAN
A-1
A-1
GROUT JAMBS FULL
GROUT JAMBS FULL
STEEL
INSUL.
SWITCH POST
WALL SWITCH
FRAME
SWITCH
FRAME
SWITCH
CONNECT DOOR CLOSERS TO NEW CIRCUIT
IN EXISTING 120V PANEL IN THIS ROOM.
SURFACE MOUNT & PAINT CONDUIT.
REMOVE & SALVAGE SCRAMBLE
PAD AND BADGE READER.
REMOVE PORTION OF CONCRETE PAVING NEW CONCRETE PAVING
24v/120-1∅ TRANSFORMER BY
GENERAL CONTRACTOR
EXTEND & CONNECT TO 1P-20A
BREAKER IN EXISTING PANEL. SEE
KEY PLAN FOR PANEL LOCATION.
48"
LOW VOLTAGE
CONTROL WIRING (TYP)
LOW VOLTAGE CONTROL
WIRING IN CONDUIT
BELOW GRADE
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AHU