HOFU_237580-FINAL CD_ COMBINED DRAWINGS-120919.pdf
PDF 4 MB Posted
- Solicitation number
- 140P4220R0061
About this file
This solicitation is for HVAC replacement, interior and exterior painting, window and door repair, deck repair, and collection storage services at the HOFU site. The National Park Service Northeast Region is seeking these services to upgrade the HVAC system, paint interior display rooms and the exterior, and properly store the museum collection. Offerors should propose pricing to remove the existing HVAC system, install a new high-efficiency system, paint all interior spaces designated for display and the building exterior, repair windows and doors, refurbish exterior decks, and remove and store the collection according to federal standards. The response deadline is not provided. The period of performance and award date are also unspecified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| prebid SV_0001.pdf | ||
| Hopewell Furnace Ironmasters Analysis of Historic Finishes- Final_0001.pdf | ||
| Questions and Answers_0001.pdf | ||
| Ironmasters House Collection Inventory_0001.xls | XLS spreadsheet | |
| Sol_140P4220R0061_Amd_0001.pdf | ||
| Sol_140P4220R0061.pdf | ||
| Bid Guarantee SF24-16d.pdf | ||
| Form B.docx | DOCX document | |
| Project Specifications-SOW Ironmaster HVAC_PAINT_COLLECTION-Rev 7-7-20.pdf | ||
| Wage Determination Chester County PA 10-02-20.pdf | ||
| PERFORMANCE BOND SF25-16d1.pdf | ||
| Form A.docx | DOCX document | |
| References Worksheet.doc | DOC document | |
| PAYMENT BOND SF25A-16d.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/3
/2
:0
:2
A
M P
\1
H
O F
U I ro n m a s te r' s H o u s e H
V A
C \R e v it \I R
O N
M A
S T
E R
'S H
O U
S E
.r v t
Designer
Author
Checker
10/30/2019
G-0.1
DRAWING INDEX
DRAWING INDEX
G - 0.0
G - 0.1
G - 0.2
A - 1.0
A - 1.1
A - 1.2
A - 1.3
A - 2.1
A - 2.2
H - 0.0
H - 1.1
H - 2.1
H - 3.1
H - 3.2
H - 3.3
H - 3.4
H - 5.0
H - 7.0
H - 8.0
E - 0.0
E - 2.1
E - 4.1
E - 4.2
E - 4.4
E - 7.1
COVER SHEET
DRAWING INDEX
SITE PLAN
BASEMENT FLOOR PLAN
FIRST FLOOR PLAN
SECOND FLOOR PLAN
ATTIC PLAN
REFLECTED CEILING PLAN - FIRST FLOOR
REFLECTED CEILING PLAN - SECOND FLOOR
HVAC COVER SHEET
HVAC ZONING PLANS
HVAC DEMOLITION PLANS
HVAC BASEMENT FLOOR NEW WORK PLAN
HVAC FIRST FLOOR NEW WORK PLAN
HVAC SECOND FLOOR NEW WORK PLAN
HVAC ATTIC NEW WORK PLAN
HVAC SECTIONS AND ENLARGED PLANS
HVAC SCHEDULES
HVAC DETAILS
ELECTRICAL COVER SHEET
ELECTRICAL DEMOLITION PLANS
ELEC POWER & SYSTEMS PLAN - BASEMENT
ELEC POWER & SYSTEMS PLAN - 1ST FLOOR
ELEC POWER & SYSTEMS PLAN - ATTIC
ELECTRICAL SCHEDULES
2 25
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/3
/2
:0
:2
A
M P
\1
H
O F
U I ro n m a s te r' s H o u s e H
V A
C \R e v it \I R
O N
M A
S T
E R
'S H
O U
S E
.r v t
Designer
AT
AW
10/30/2019
G-0.2
SITE PLAN
TO
ENTRANCE TO VALLEY
IRONMASTER'S
VISITOR CENTER
TO READING
F R
E N
C H
C R
E E
K
VILLAGE
BARN
APPROPRIATE
STAGING AREA
SITE PLAN
NOT TO SCALE
MAINTENANCE
PARKING
(PAVED)
GRAVEL ROADS,
TYPICAL
VEHICLE ACCESS,
TYPICAL
STORE &
OFFICE
WALKWAY
& STEPS
FURNACE
3 25
DN
UP
UP
MOULDERS
DINING ROOM
KITCHEN
STAGING AREA; PROTECT GROUND
SURFACE& WALLS FROM DAMAGE;
PROTECT OR REPLACE RED SHALE
HVAC UNIT
REMOVE & REINSTALL
EXISTING WOOD FASCIA CONDENSING UNIT AND
CONCRETE PAD
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-1.0
BASEMENT FLOOR PLAN
1/4" = 1'-0"1 BASEMENT FLOOR PLAN
0 4 84
SCALE OF FEET
4 25
DN
UP
DN
UP
DN
NORTHWEST
PARLOR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
STAIR
HVAC UNIT
HVAC PIPING UP & DOWN; PARK TO
PROVIDE FALSE BACK AT FIREBOX
ADJUST LOCATION OF FLOOR GRILLES AS
NECESSARY TO FIT IN FLOOR BOARD AND
AVOID EXISTING FRAMING. TYPICAL FOR ALL.
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-1.1
FIRST FLOOR PLAN
1/4" = 1'-0"1 FIRST FLOOR PLAN
0 4 84
5 25
DNDN
DN
UP
DN
HVAC PIPING UP & DOWN IN FLUE
BATHROOM
BEDROOM
BEDROOM
209STAIR HALL
BEDROOM
CLOSET HALL
BEDROOM
BEDROOM
BEDROOM
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-1.2
SECOND FLOOR PLAN
1/4" = 1'-0"1 SECOND FLOOR PLAN
0 4 84
6 25
HVAC PIPING DOWN
303 304
TRUSS BRACING THIS AREA
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-1.3
ATTIC PLAN
1/4" = 1'-0"1 ATTIC FLOOR PLAN
0 4 84
7 25
104 105
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-2.1
REFLECTED CEILING PLAN -
FIRST FLOOR
1/4" = 1'-0"1 RCP - FIRST FLOOR
0 4 84
8 25
203 202
208 209
ADJUST REGISTER AND GRILLE LOCATIONS TO
AVOID EXISTING FRAMING. TYPICAL FOR ALL
REGISTERS AND GRILLES.
SUPPLY REGISTER
RETURN GRILLE
LEGEND
RETURN AIR GRILLE ABOVE
PAINTING SCOPE
1. TOUCH UP ALL PAINT DAMAGED BY THIS WORK. PAINT
ANY NEW WOOD INSTALLED. COR TO PROVIDE PAINT
COLOR AND TYPE INFORMATION.
2. AT ROOMS 001, 002 & 003, TOUCH UP ANY PAINT AT STEEL
STRUCTURE, DOORS, DOOR FRAMES, OR STAIRS
DAMAGED BY THIS WORK.
3. AT ROOMS 004 AND 005, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
4. AT ROOMS 101, 102, 103, 104 & 105, ALL SURFACES TO BE
PAINTED IN ACCORDANCE WITH THE HISTORIC FINISHES
REPORT.
5. AT ROOM 204, ALL SURFACES TO BE PAINTED IN
ACCORDANCE WITH THE HISTORIC FINISHES REPORT.
6. IN ROOMS WITH NEW CEILING GRILLES, REPAINT
SURROUNDING CEILING SURFACE TO A NATURAL
SURFACE BREAK - TRIM, CHANGE IN PLANE, ETC.
PAINTING IS NOT REQUIRED IF THERE IS NO DAMAGE TO
EXISTING PAINT OR PLASTER
1/4" = 1'-0"1 RCP - SECOND FLOOR
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
REPLACE RADIANT HEATING SYSTEM
AT IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENTS
HOFU 237580
/9
/2
3:
:2
PM
P:
\1
8\
H
O
FU
Ir on m as te r's
H ou se H
VA
C
\R ev it\
IR
O N
M
AS
TE
R
'S H
O U
SE
.rv t
AW
AT
AW
10/30/2019
A-2.2
REFLECTED CEILING PLAN -
SECOND FLOOR
0 4 84
9 25
HVAC ABBREVIATIONS
COMPRESSED AIR PIPING
AUTOMATIC AIR VENT
AIR COMPRESSOR
AIR CONDITIONING FAN (AIR HANDLING UNIT)
DUCT ACCESS DOOR
ABOVE FINISHED FLOOR
ACCESS PANEL
AIR PRESSURE DROP
AIR SEPARATOR
AUTOMATIC TEMPERATURE CONTROLS
BOILER
BRANCH CONTROLLER
BACKDRAFT DAMPER
BOTTOM OF DUCT
BOTTOM OF PIPE
BRITISH THERMAL UNIT
BTU PER HOUR
CONDENSATE
CEILING DIFFUSER
CEILING EXHAUST GRILLE
CEILING EXHAUST REGISTER
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CHILLER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CLEAN OUT
CONDENSATE
CONTINUED
CONDENSATE PUMP
CEILING RETURN GRILLE
CEILING RETURN REGISTER
CEILING SUPPLY GRILL
COOLING TOWER
CONDENSING UNIT
CABINET UNIT HEATER
CONSTANT VOLUME
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
COOLING CONDENSATE DRAIN PIPING
DRY BULB/DECIBEL
A-WEIGHTED DECIBEL
DIRECT DIGITAL CONTROLS
DIAMETER
DOWN
DUCT MOUNTED SUPPLY GRILLE
DIRECT EXPANSION
EXHAUST AIR
ENTERING AIR TEMPERATURE
ELECTRIC BASEBOARD RADIATOR
ELECTRICAL CONTRACTOR
EXHAUST FAN
ENERGY RECOVERY WHEEL
EXTERNAL STATIC PRESSURE
EXPANSION TANK
ENTERING WATER TEMPERATURE
EXISTING
FURNACE/FAHRENHEIT
FORCED CONDENSATE
FLOOR DRAIN
FLEXIBLE
SPRINKLER/FIRE PROTECTION CONTRACTOR
FEET PER MINUTE
FLOOR RETURN GRILL
FLOOR SUPPLY REGISTER
FOOT/FEET
FIN-TUBE CONVECTOR
GAS
GRAVITY CONDENSATE
GROUND COUPLED RETURN
GROUND COUPLED SUPPLY
GALLONS PER MINUTE
A
AAV
AC
AHU
AD
AFF
AP
APD
AS
ATC
B
BC
BDD
BOD
BOP
BTU
BTUH
C
CD
CEG
CER
CFH
CFM
CH
CHWR
CHWS
CO
COND
CONT
CP
CRG
CRR
CSG
CT
CU
CUH
CV
CWR
CWS
D
DB
DBA
DDC
DIA
DN
DSG
DX
EA
EAT
EBR
EC
EF
ERW
ESP
ET
EWT
(E) F
FC
FD
FLEX
FPC
FPM
FRG
FSR
FT
FTC
G
GC
GCR
GCS
GPM
HEAT PUMP/HORSE POWER
HOT WATER
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
HEAT EXCHANGER
LEAVING AIR TEMPERATURE
LINEAR DIFFUSER - RETURN
LINEAR BAR GRILLE
LINEAR DIFFUSER
LOW PRESSURE STEAM SUPPLY
LINEAR SUPPLY REGISTER
LINEAR RETURN GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTUH
MECHANICAL CONTRACTOR
MINIMUM FUSE AMPACITY
MOTORIZED DAMPER
MINIMUM
MAXIMUM OVER-CURRENT PROTECTION SIZE
NEW WORK
NOT APPLICABLE
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OPPOSED BLADE DAMPER
OPEN ENDED DUCT
PUMP
PLUMBING CONTRACTOR/ PUMPED CONDENSATE
PRESSURE REDUCING VALVE
POUNDS PER SQUARE INCH
PACKAGED TERMINAL AIR CONDITIONER
REFRIGERANT GAS RETURN LINE
RETURN AIR
RELATIVE HUMIDITY
REFRIGERANT RETURN
RADIANT PANEL
REVOLUTIONS PER MINUTE
REFRIGERANT SUPPLY
ROOF TOP UNIT
SLOPE
SANITARY/SLOPE
SUPPLY AIR
SECONDARY CHILLED WATER SUPPLY OR RETURN
SQUARE FEET
TESTING, ADJUSTING & BALANCING
TRANSFER AIR GRILLE
TERTIARY CHILLED WATER SUPPLY OR RETURN
TOTAL DEVELOPED HEAD(DYNAMIC)
TEMPERED OUTSIDE AIR
TOP OF DUCT
TRANSITION
TOTAL STATIC PRESSURE
TYPICAL
UNIT HEATER
UNLESS NOTED OTHERWISE
VARIABLE AIR VOLUME
VOLUME DAMPER
VARIABLE FREQUENCY DRIVE
VERIFY IN FIELD
VARIABLE REFRIGERANT FLOW
WET BULB
WALL EXHAUST GRILLE
WALL EXHAUST REGISTER
WATER PRESSURE DROP
WALL RETURN REGISTER
WALL SUPPLY GRILLE
WATER SOURCE HEAT PUMP
WALL SUPPLY REGISTER
WIRE MESH SCREEN
HP
HW
HWS
HWR
HTX
LAT
LDR
LBG
LD
LPS
LSR
LRG
LWT
MAX
MBH
MC
MCA
MD
MIN
MOCP
(N) N/A
NC
NIC
NO
NTS
OA
OBD
OED
P
PC
PRV
PSI
PTAC
R
RA
RH
RL
RP
RPM
RS
RTU
s=02'
S
SA
SCHWS/R
SF
TAB
TAG
TCHWS/R
TDH
TOA
TOD
TR
TSP
TYP
UH
U.N.O.
VAV
VD
VFD
VIF
VRF
WB
WEG
WER
WPD
WRR
WSG
WSHP
WSR
WMS
HVAC PLAN SYMBOLS
AIRFLOW DIRECTION
SYMBOL
UNDERCUT DOOR
EQUIPMENT TAG
SECTION MARKER
DIAMETER
CONNECT NEW TO EXISTING
CUT AND CAP
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO BE RELOCATED
HUMIDITY SENSOR / HUMIDISTAT
TEMPERATURE SENSOR / THERMOSTAT
SMOKE DETECTOR
(E)
(R)
(RL)
H
T
EQUIPMENT
NUMBER
EQUIPMENT TYPE
DESIGNATOR
SHEET NUMBER
SECTION NUMBER
X
XX
S
CARBON DIOXIDE SENSORCO2
PIPE ANCHOR
PIPE GUIDE
PIPE CAP
EXISTING TO REMAIN
EXISTING TO BE REMOVED
(DEMO PLANS)
NEW WORK
PIPE UP
PIPE DOWN
PIPE DROP
PIPE UNION
PIPE TAKE-OFF UP
RETURN PIPING
(NEW WORK
PLANS)
U
LOUVERED DOOR L
XX
XXX
"CRR OR FRG" TYPE RETURN AIR GRILLE
"CD OR FSR" TYPE SUPPLY AIR DIFFUSER
BALL VALVE
HVAC VALVE SYMBOLS HVAC GRILLE SYMBOLS
PLAN
SECTION
DETAILS
VOLUME DAMPER
HVAC DUCT SYMBOLS
RETURN, EXHAUST, MAKEUP,
OR OUTSIDE AIR INTAKE
SUPPLY AIRFLOW
DUCT SIZE - RECTANGULAR
DUCT SIZE - ROUND
DUCT SIZE - FLAT OVAL
## x ##
## Ø
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H0.0
HVAC COVER SHEET
EXAMINE JOB SITE AND VERIFY ALL SITE
CONDITIONS PRIOR TO SIGNING CONTRACT. BRING
ANY DISCREPANCY BETWEEN THE CONTRACT
DOCUMENTS AND THE ACTUAL FIELD CONDITIONS
TO THE ATTENTION OF THE CONTRACTOR OF
RECORD.
THE DRAWINGS ARE DIAGRAMMATIC. COORDINATE
IN THE FIELD, WITH THE CONTRACTOR OF RECORD
AND WITH ALL TRADES, THE EXACT LOCATION OF
EQUIPMENT, DUCTWORK, AND PIPING.
PERFORM WORK IN ACCORDANCE WITH RULES,
REGULATIONS, STANDARDS, CODES, ORDINANCES,
AND LAWS OF LOCAL, STATE, AND FEDERAL
GOVERNMENTS, AND OTHER AUTHORITIES HAVING
JURISDICTION AND BE RESPONSIBLE FOR
COMPLIANCE THEREWITH.
OBTAIN ALL NECESSARY APPROVALS, PERMITS AND
INSPECTIONS. PAY ALL ASSOCIATED FEES.
CONTRACTOR’S SHALL MAINTAIN A NOTATED SET OF
“AS-BUILT” DRAWINGS ONSITE SHOWING ALL
DEVIATIONS FROM THE CONTRACT DRAWINGS AND
SHALL TURN THEM OVER TO THE CONTRACTOR OF
RECORD UPON SUBSTANTIAL COMPLETION.
ALL MATERIALS SHALL BE NEW AND OF
COMMERCIAL GRADE AND BEAR THE
UNDERWRITER'S LABEL WHERE APPLICABLE.
OBTAIN APPROVAL FROM THE PARK SERVICE
REPRESENTATIVE PRIOR TO ANY INTERRUPTION OF
BUILDING SYSTEMS. COORDINATE ACCEPTABLE
WORKING HOURS WITH SAME.
1.
2.
3.
4.
5.
6.
7.
HVAC GENERAL NOTES:
HVAC DRAWING SCHEDULE
SHEET
NUMBER SHEET NAME
100% CD
10/30/19
H0.0 HVAC COVER SHEET ●
H1.1 HVAC ZONING PLANS ●
H2.1 HVAC DEMOLITION PLANS ●
H3.1 HVAC BASEMENT FLOOR NEW WORK PLAN ●
H3.2 HVAC FIRST FLOOR NEW WORK PLAN ●
H3.3 HVAC SECOND FLOOR NEW WORK PLAN ●
H3.4 HVAC ATTIC NEW WORK PLAN ●
H5.0 HVAC SECTIONS AND ENLARGED PLANS ●
H7.0 HVAC SCHEDULES ●
H8.0 HVAC DETAILS ●
UP
UP
DN
UP
DN
UP
DNDN
UP
DN
MOULDERS
DINING RM.
KITCHEN
VRF 0-3
VRF 0-4
NORTHWEST
PARLOR
STAIR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
VRF 0-5
VRF 0-2
VRF 0-1
VRF 0-6 VRF 1-1
BEDROOM
BEDROOM
STAIR HALL
CLOSET HALL
BEDROOM
BEDROOM
BEDROOM
BEDROOM
VRF 2-1 VRF 2-2
VRF 2-3 VRF 2-4
VRF 2-6
VRF 2-5
VRF 0-2
NO CONDITIONING PROVIDED
303 304
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H1.1
HVAC ZONING PLANS
1/8" = 1'-0"H1.1
1 HVAC BASEMENT ZONING PLAN
1/8" = 1'-0"H1.1
2 HVAC FIRST FLOOR ZONING PLAN
1/8" = 1'-0"H1.1
3 HVAC SECOND FLOOR ZONING PLAN
1/8" = 1'-0"H1.1
4 HVAC ATTIC ZONING PLAN
0 4 84
UP
UP
DN
UP
DN
UP
DNDN
UP
DN
MOULDERS
DINING RM.
KITCHEN
(E) 14"
OPENING
(R) CABINET
UNIT HEATER(S)
(E) DEHUMIDIFIER
TO REMAIN
(E) UH TO
REMAIN
(E) UH TO
REMAIN
(E) UH TO
REMAIN
(E) WOODEN REVEAL
NORTHWEST
PARLOR
STAIR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
NOTES:
IN FLOOR ELECTRIC RADIANT HEAT TO BE ABANDONED IN
PLACE WHERE NO PLASTER, PATCH.
(E) FLOOR
GRILLE TO
REMAIN
(E) FLOOR
GRILLE TO
REMAIN
BEDROOM
BEDROOM
STAIR HALL
CLOSET HALL
BEDROOM
BEDROOM
BEDROOM
BEDROOM
NOTES:
NO DEMOLITION SCOPE ON THIS FLOOR.
FLOOR SHOWN FOR REFERENCE ONLY.
303 304
NOTES:
NO DEMOLITION SCOPE ON THIS FLOOR.
FLOOR SHOWN FOR REFERENCE ONLY.
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H2.1
HVAC DEMOLITION PLANS
1/8" = 1'-0"H2.1
1 HVAC BASEMENT DEMOLITION PLAN
1/8" = 1'-0"H2.1
2 HVAC FIRST FLOOR DEMOLITION PLAN
1/8" = 1'-0"H2.1
3 HVAC SECOND FLOOR DEMOLITION PLAN
1/8" = 1'-0"H2.1
4 HVAC ATTIC DEMOLITION PLAN
UP
UP
MOULDERS
DINING RM.
KITCHEN
(E) DEHUMIDIFIER
TO REMAIN
(E) UH TO
REMAIN
(E) UH TO
REMAIN
(E) UH TO
REMAIN
(E) WOODEN
REVEAL
BC
VRF
0-5
12"ø RA UP
8ø SA UP
VRF
0-1
COND UP
14ø SA UP
8ø SA UP
8"ø SA UP
8ø SA UP
VRF
0-2
VRF
0-4
VRF
0-6
16ø RA UP
20x10 RA x
R
A
EACH LINE REPRESENTS 2 SETS
OF REFRIGERANT LINES (RS/RL)
BETWEEN BC AND VRF UNITS
CU
REFRIGERANT MAIN
DROP TO 24" AFF
SOUND ATTENUATORS
LINE OF
STRUCTURE
ABOVE
H5.0
DRIP LINE OF ROOF ABOVE
COND SPILL TO GRADE
RS/RL UP
CONDENSATE UP
REFRIGERANT SUCTION,
GAS, MIXTURE UP TO BC-2
14ø RA20x10 SA
10ø SA
10ø SA
H5.0
H5.0
10ø SA 10ø SA
18x16 SA
10x10 RA
VRF
0-3
T
T
VRF
0-6
VRF
0-3
CORE
THROUGH WALL
42"x110" CONCRETE PAD
CO
RACK PIPES ON
STONE WALL
H5.0
Sim
1 1/4" GC
1 1/4" GC
26x8 SA
SG
410 CFM
12x12
WSR9
H5.0
RG ABOVE
PROVIDE 10 GPH CONDENSATE PUMP WITH 20FT
OF HEAD. BASIS OF DESIGN IS LITTLE GIANT
VCMX-2OULS. PROVIDE PUMP WITH CORD AND
PLUG.
TEMPERATURE SENSOR/ THERMOSTAT
LOCATIONS SHALL BE COORDINATED WITH COR.
(TYP. FOR ALL).
HVAC NEW WORK KEYED NOTES:
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H3.1
HVAC BASEMENT FLOOR
NEW WORK PLAN
1/4" = 1'-0"H3.1
1 HVAC BASEMENT NEW WORK AND PIPING PLAN
NOTES:
1. ALL PIPING, EQUIPMENT AND DUCTWORK SHALL BE LOCATED TIGHT TO OVERHEAD STRUCTURE.
UP
DN
UP
NORTHWEST
PARLOR
STAIR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
(E) 12" ø VENT (RA)
360 CFM
VRF
1-1
(E) 14" ø VENT (RA)
860 CFM
REFRIGERANT SUCTION,
LIQUID, MIX UP/DN TO BC 1
COND UP/DN
RS/RL DN
CONDENSATE DN.
T
T
T
VRF
0-5
VRF
0-2
VRF
0-1
T
T
VRF
0-6
VRF
1-1
HVAC CONTROL PANEL
1 1
H5.0
FRR
410 CFM
(12"Ø)
FSR
410 CFM
(12"Ø)
FSR
180 CFM
(8"Ø) TYP. FOR TWO
FSR
500 CFM
(12"Ø)
FSR
180 CFM
(8"Ø)
FSR
180 CFM
(8"Ø)
COORDINATE NEW DIFFUSER LOCATIONS WITH
BEAMS AND JOISTS.
TEMPERATURE SENSOR/ THERMOSTAT
LOCATIONS SHALL BE COORDINATED WITH COR.
(TYP. FOR ALL).
HVAC NEW WORK KEYED NOTES:
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H3.2
HVAC FIRST FLOOR NEW
WORK PLAN
1/4" = 1'-0"H3.2
1 HVAC FIRST FLOOR NEW WORK PLAN
DNDN
BEDROOM
BEDROOM
STAIR HALL
CLOSET HALL
BEDROOM
BEDROOM
BEDROOM
BEDROOM
CSG
350 CFM
CSG
350 CFM
14x6 CRG
350 CFM
CSG
125 CFM
CRG
700 CFM
CSG
350 CFM
1-1/4" COND
UP/DN
CSG
350 CFM
CRG
700 CFM
CRG
700 CFM
CSG
225 CFM
CSG
350 CFM
CSG
350 CFM
CSG
350 CFM
CRG
350 CFM
CRG
350 CFM
14x6 CSG
350 CFM
REFRIGERANT SUCTION,
LIQUID, MIX DN TO BC 1
SA UP (TYP.)
RA UP (TYP.)
TT
VRF
2-4
VRF
2-3
T
VRF
2-6
T
VRF
2-5
T
VRF
2-2
T
VRF
2-1
H5.0
1 1 1 1
COORDINATE NEW DIFFUSER LOCATIONS WITH
BEAMS AND JOISTS.
TEMPERATURE SENSOR/ THERMOSTAT
LOCATIONS SHALL BE COORDINATED WITH COR.
(TYP. FOR ALL).
HVAC NEW WORK KEYED NOTES:
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :0
P
M
SAW
DAI
CSA
10/30/19
H3.3
HVAC SECOND FLOOR NEW
WORK PLAN
1/4" = 1'-0"H3.3
1 HVAC SECOND FLOOR NEW WORK PLAN
VRF
2-1
VRF
2-6
VRF
2-3
VRF
2-4
H5.0
VRF
2-2
VRF
2-5
BC
REFRIGERANT SUCTION,
LIQUID, MIX DN TO BC 1
CO
EACH LINE REPRESENTS 2 REFRIGERANT LINES
(RS/RL) TO EACH INDOOR UNIT (TYP.) BETWEEN
BC AND VRF UNITS
1 1/4" GC
1 1/4" GC
1 1/4" GC
1 1/4" GC
1 1/4" GC
1 1/4" GC
1-1/4" CONDENSATE DN.
CO
12ø SA DN (TYP.)
12ø RA DN. (TYP.)
10ø SA DN TO GRILLE 10ø SA DN TO GRILLE
H5.0
H5.0
16x12 RA DN TO GRILLE.
10" ø SA DN TO GRILLE. (TYP)
12ø RA
10ø SA
12" ø SA DN TO GRILLE. (TYP)
20x10 SA
12ø SA
12ø SA
14ø SA
12ø SA
12ø SA
14ø SA
12ø SA
BELOW
12ø SA
12ø SA
12ø RA
12ø RA
10ø RA DN TO GRILLE
12ø SA10ø SA
10ø SA DN TO GRILLE
12ø SA 10ø SA DN TO GRILLE
10ø RA DN TO GRILLE
12ø SA
16x12 RA DN
TO GRILLE.
COORDINATE NEW DIFFUSER LOCATIONS WITH
BEAMS AND JOISTS.
TEMPERATURE SENSOR/ THERMOSTAT
LOCATIONS SHALL BE COORDINATED WITH COR.
(TYP. FOR ALL).
HVAC NEW WORK KEYED NOTES:
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :1
P
M
SAW
DAI
CSA
10/30/19
H3.4
HVAC ATTIC NEW WORK
PLAN
1/4" = 1'-0"H3.4
1 HVAC ATTIC NEW WORK PLAN
NOTES:
1. ALL PIPING, EQUIPMENT AND DUCTWORK SHALL BE LOCATED TIGHT TO OVERHEAD STRUCTURE.
BASEMENT
-8' - 6"
FIRST FLOOR
0' - 0"
2' - 0"
CU
UNIT DISCHARGE
SOUND ATTENUATOR
RACK REF
PIPING ON WALL
H8.0
UNIT SOUND
ATTENUATOR PANELS
BASEMENT
-8' - 6"
FIRST FLOOR
0' - 0"
VRF
0-6
VRF
1-1
3/4" GC
3/4" REF
3/4" REF
3/4" REF
3/4" REF
3/4" REF
FSR
VRF
0-3
CONDESATE
PUMP
18x18 RA700 CFM 14x14
SG
410 CFM
12x12
WSR
BASEMENT
-8' - 6"
FIRST FLOOR
0' - 0"
VRF
0-2
10x10 RA
16x18 SA
14ø SA
FSR
500 CFM
12" ø
H5.0
VRF
0-4
VRF
0-6
VRF
0-3
CP
ATTIC FLOOR
18' - 10"
ROOF PLAN
27' - 9"
VRF
2-1 VRF
2-2
10ø SA
12ø SA
ATTIC FLOOR
18' - 10"
ROOF PLAN
27' - 9"
VRF
2-3
12ø SA
12ø SA
12x16 RA
ATTIC FLOOR
18' - 10"
ROOF PLAN
27' - 9"
VRF
2-5
12ø SA
10ø SA
10ø RA
10ø SA
CSG
350 CFM
14x6
CRG
700 CFM
14x6
CRG
350 CFM
14x6
VRF
0-6
VRF
0-4
18x18 RA
10x12 SA
SG
410 CFM
12x12
OPEN ENDED
DUCT W/ WMS
410 CFM
14x14
FSR
410 CFM
(12"Ø)
BASEMENT
-8' - 6"
FIRST FLOOR
0' - 0"
STAIR
NORTHWEST
PARLOR
(E)14" VENT
14ø RA
20x10 RA
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :1
P
M
SAW
DAI
CSA
10/30/19
H5.0
HVAC SECTIONS AND
ENLARGED PLANS
3/8" = 1'-0"H5.0
2 HVAC SECTION AT CU-1
1/4" = 1'-0"H5.0
3 HVAC SECTION AT VRF 0-6
3/8" = 1'-0"H5.0
1 HVAC SECTION AT VRF 0-2
3/8" = 1'-0"H5.0
4 HVAC BASEMENT NEW WORK AND PIPING PLAN
3/8" = 1'-0"H5.0
5 HVAC SECTION AT VRF 2-1 & 2-2
3/8" = 1'-0"H5.0
6 HVAC SECTION AT VRF 2-3
3/8" = 1'-0"H5.0
7 HVAC SECTION AT VRF 2-5
H5.0
8 ISOMETRIC VIEW OF VRF 0-4 & 0-6
1/4" = 1'-0"H5.0
9 SECTION 102
AIR DEVICE SCHEDULE
FINISHMATERIALDESIGNATION
FACE/
SLOTS/
SPACING
REMARKS
CSG
BORDER BASIS
FRG
NOTES:
1. REFER TO FLOOR PLANS FOR BALANCING CFM AND THE TAKE-OFF SCHEDULE FOR THE NECK SIZE OF EACH DEVICE.
2. CONTRACTOR TO COORDINATE AIR DEVICE BORDER TYPE WITH STRUCTURE. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.
FSR CUSTOM GRILLE PROVIDE VOLUME DAMPER IN DUCT SERVING GRILLEBLACK INTEGRAL
VINTAGE
HARDWARE
ZM-IR
CAST IRON
CRG
VINTAGE
HARDWARE
ZM-IR
REGGIO
REGISTERS
CAST IRON
CAST IRON
CAST IRON
BLACK
WHITE
WHITE
CUSTOM GRILLE
CUSTOM GRILLE
"SCROLL"
CUSTOM GRILLE
"SCROLL"
INTEGRAL
INTEGRAL
INTEGRAL
PROVIDE VOLUME DAMPER IN DUCT SERVING GRILLE
PROVIDE VOLUME DAMPER IN DUCT SERVING GRILLE
PROVIDE VOLUME DAMPER IN DUCT SERVING GRILLE
REGGIO
REGISTERS
SG STEEL WHITE 3/4" DOUBLE DEFLECTION 1-1/4" PROVIDE WITH FOAM GASKETTITUS 300 RL
MINIMUM INSERTION LOSS FOR DUCT
SILENCER FOR CONDENSING UNIT SCHEDULE
OCTAVE BAND CENTER FREQUENCY (HZ)
PATHSILENCER
NOTES: COORDINATE PRESSURE DROP WITH MANUFACTURER REQUIREMENTS
DS-1
CU-1
DISCHARGE
1K
2K
4K
8K
MANUFACTURER SOUND PRESSURE LEVELS
FOR MECHANICAL UNITS SCHEDULE
SOUND PRESSURE LEVELS (DB RE. 20 µPA)
MODEL
NOTES:
PEFY-P12NMAU-E
63 HZ
125 HZ
250 HZ
500 HZ
1 KHZ
2 KHZ
4 KHZ
8 KHZ
PEFY-P30NMAU-E 43 42 39 37 34 29 22 24
PVFY-P18NAMU-E 44 43 41 39 35 31 28 24
PFFY-P12NMAU-E 40 43 41 42 34 29 20 17
CU-1 71 68 64 57.5 54 46.5 48.5 45
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :1
P
M
SAW
DAI
CSA
10/30/19
H7.0
HVAC SCHEDULES
BRANCH CONTROLLER SCHEDULE
SYMBOL
LOCATION
INDOOR UNITS SERVED
(VRF-#)
CONNECTED
CONDENSING
UNIT
NUMBER OF
PORTS
PHYSICAL CHARACTERISTICS ELECTRICAL BASIS OF DESIGN
REMARKS
TAG NO.
LENGTH
(IN.)
WIDTH
(IN.)
HEIGHT
(IN.)
WEIGHT
(LBS.)
V/PH/HZ MCA MOCP MANUFACTURER MODEL NO
BC 1 RM 001 0-1, 0-2, 0-3, 0-4, 0-5, 0-6, 1-1 CU-1 8 43-3/4 20-1/2 11-7/16 124 230/1/60 1.45 15 MITSUBISHI ELECTRIC CMB-P108NU-HA1 SEE NOTES BELOW
BC 2 ATTIC 301 2-1, 2-2, 2-3, 2-4, 2-5, 2-6 CU-1 8 23-1/2 15-11/16 9-7/8 69 230/1/60 0.87 15 MITSUBISHI ELECTRIC CMB-P108NU-KB1 SEE NOTES BELOW
VARIABLE REFRIGERANT FLOW INDOOR UNIT SCHEDULE
SYMBOL
LOCATION TYPE
CAPACITY MBH ELECTRICAL FAN ELECTRICAL DIMENSIONS
OPER
WEIGHT
BASIS OF DESIGN
REMARKSTAG NO COOLING HEATING V/PH/HZ CFM
POWER
(WATTS) MCA MOCP L W H MANUFACTURER MODEL NO
VRF 0-1 RM 003 DUCTED HORIZONTAL 12 13.5 230/1/60 211-282-370 96 1.2 15 27-9/16" 31-1/8" 7-7/8" 46 MITSUBISHI ELECTRIC PEFY-P12NMAU SEE NOTES BELOW
VRF 0-2 RM 002 DUCTED VERTICAL 18 20 230/1/60 410-497-585 110 3 15 17" 21-5/8" 50-1/4" 113 MITSUBISHI ELECTRIC PVFY-P18NAMU SEE NOTES BELOW
VRF 0-3 RM 004 FLOOR STANDING 12 13.5 230/1/60 247-317 90 0.38 15 46-3/32" 8-11/16" 24-13/16" 50 MITSUBISHI ELECTRIC PFFY-P12NEMU SEE NOTES BELOW
VRF 0-4 KITCHEN 005 DUCTED VERTICAL 18 20 230/1/60 410-497-585 110 3 15 17" 21-5/8" 50-1/4" 113 MITSUBISHI ELECTRIC PVFY-P18NAMU SEE NOTES BELOW
VRF 0-5 RM 001 DUCTED HORIZONTAL 12 13.5 230/1/60 211-282-370 96 1.2 15 27-9/16" 31-1/8" 7-7/8" 46 MITSUBISHI ELECTRIC PEFY-P12NMAU SEE NOTES BELOW
VRF 0-6 KITCHEN 005 DUCTED VERTICAL 18 20 230/1/60 410-497-585 110 3 15 17" 21-5/8" 50-1/4" 113 MITSUBISHI ELECTRIC PVFY-P18NAMU SEE NOTES BELOW
VRF 1-1 KITCHEN 105 FLOOR STANDING 12 13.5 230/1/60 247-317 90 0.38 15 46-3/32" 8-11/16" 24-13/16" 50 MITSUBISHI ELECTRIC PFFY-P12NEMU SEE NOTES BELOW
VRF 2-1 ATTIC 302 DUCTED HORIZONTAL 12 13.5 230/1/60 211-282-370 96 1.2 15 27-9/16" 31-1/8" 7-7/8" 46 MITSUBISHI ELECTRIC PEFY-P12NMAU SEE NOTES BELOW
VRF 2-2 ATTIC 302 DUCTED HORIZONTAL 12 13.5 230/1/60 211-282-370 96 1.2 15 27-9/16" 31-1/8" 7-7/8" 46 MITSUBISHI ELECTRIC PEFY-P12NMAU SEE NOTES BELOW
VRF 2-3 ATTIC 303 DUCTED HORIZONTAL 30 34 230/1/60 512-636-742 140 2.50 15 28-7/8" 43-5/16" 9-13/16" 71 MITSUBISHI ELECTRIC PEFY-P30NMAU SEE NOTES BELOW
VRF 2-4 ATTIC 304 DUCTED HORIZONTAL 30 34 230/1/60 512-636-742 140 2.50 15 28-7/8" 43-5/16" 9-13/16" 71 MITSUBISHI ELECTRIC PEFY-P30NMAU SEE NOTES BELOW
VRF 2-5 ATTIC 301 DUCTED HORIZONTAL 12 13.5 230/1/60 211-282-370 96 1.2 15 27-9/16" 31-1/8" 7-7/8" 46 MITSUBISHI ELECTRIC PEFY-P12NMAU SEE NOTES BELOW
VRF 2-6 ATTIC 301 DUCTED HORIZONTAL 30 34 230/1/60 512-636-742 140 2.50 15 28-7/8" 43-5/16" 9-13/16" 71 MITSUBISHI ELECTRIC PEFY-P30NMAU SEE NOTES BELOW
AIR COOLED HEAT PUMP CONDENSING UNIT SCHEDULE
SYMBOL
LOCATION SERVICE TYPE EER IEER
NOM
CAPACITY
(MBH)
MIN
AMBIENT
TEMP
FAN ELECTRICAL
OPERATING
WEIGHT
BASIS MANUFACTURER
REMARKSTAG NO. QTY V/PH/HZ MCA MOCP NAME MODEL NO
CU 1 GRADE ALL VRF UNITS HEAT RECOVERY 12.1 23.9 192 23 2 230/3/60 (2)33 (2)45 1100 MITSUBISHI PURY-192TSLNU SEE NOTES BELOW
NOTES:
PROVIDE PAINTED INLET AND DISCHARGE SOUND ATTENUATORS, COORDINATE COLOR WITH COR.
ELECTRICAL TRADES CONTRACTOR SHALL PROVIDE DISCONNECTS MATCHED TO THE EQUIPMENT.
NOMINAL COOLING AND HEATING CAPACITIES ARE BASED ON INDOOR AIR COIL EAT OF 80/67 °F (DB/WB), OUTDOOR OF 95°F.
NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 54°F (DB), OUTDOOR OF 5°F(DB).
EFFICIENCY VALUES FOR EER, IEER, COP ARE BASED ON AHRI 1230 TEST METHOD FOR MIXTURE OF DUCTED & NON-DUCTED INDOOR UNITS. FOR SYSTEMS WITH MULTIPLE MODULES, REFRIGERANT PIPE DIMENSIONS INDICATE TOTAL SYSTEM
COMBINED PIPING DOWNSTREAM OF MODULE TWINNING.
ADDED REFRIGERANT FIELD CHARGE IS IN ADDITION TO FACTORY CHARGE, THIS MUST BE UPDATED BASED UPON FINAL AS-BUILT PIPING LAYOUT.
PROVIDE WITH CENTRAL CONTROLLER (AE-200), SEE DWGS.
UNIT IS DESIGNED TO PROVIDE NOMINAL HEATING TO MAINTAIN SPACE AT 55°F DURING WINTER DESIGN CONDITIONS.
NOTES:
ELECTRICAL TRADES CONTRACTOR SHALL PROVIDE NON-FUSED DISCONNECTS MATCHED TO THE EQUIPMENT.
NOMINAL COOLING AND HEATING CAPACITIES ARE BASED ON INDOOR AIR COIL EAT OF 80/67 °F (DB/WB), OUTDOOR OF 95 °F.
NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 70°F (DB), OUTDOOR OF 43°F(DB).
SEE OUTDOOR UNIT SCHEDULE FOR OUTDOOR AMBIENT CONDITIONS, CONNECTED CAPACITY, AND OTHER FACTORS ASSOCIATED WITH CORRECTED UNIT CAPACITIES.
SEE SCHEMATIC PIPING/ CONTROL DIAGRAM FOR INDICATION OF REQUIRED INDOOR UNIT REMOTE CONTROLLERS, SYSTEM CONTROLLERS, AND INTEGRATION DEVICES.
CONTROLS FOR EACH AC UNIT BY UNIT MANUFACTURER.
UNIT SHALL BE CONTROLLED BY WALL MOUNTED WIRELESS CONTROLLER
PROVIDE HORIZONTAL UNITS WITH INTEGRAL CONDENSATE LIFT DEVICES
PROVIDE HORIZONTAL DUCTED UNITS WITH FILTER BOXES TO ACCOMODATE A 2" FILTER
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
3.
4.
5.
6.
7.
8.
NOTES:
ELECTRICAL TRADES CONTRACTOR SHALL PROVIDE ALL DISCONNECTS MATCHED TO THE EQUIPMENT.
PROVIDE REFRIGERANT ISOLATION BALL VALVES FOR ALL REFRIGERANT LIQUID AND SUCTION PIPING. SPARE PORTS TO BE PROVIDED WITH VALVES AND SEALED PER
MANUFACTURER'S RECOMMENDATIONS.
1.
2.
NOTE:
VRF SYSTEM IMAGE IS DIAGRAMMATIC IN NATURE AND IS REPRESENTATIVE ONLY OF THE OVERALL SYSTEM DESIGN INTENT. ALL DETAILS, INCLUDING BUT NOT LIMITED TO REFRIGERANT PIPING LENGTHS AND REFRIGERANT CHARGE VOLUMES, ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO DETERMINE IN ACCORDANCE
WITH MANUFACTURER'S INSTALLATION REQUIREMENTS.
SA (SIZE VARIES)
UNIT
ISOLATOR
(TYP OF (4))
CLIP ANGLE
(TYP)
CINCH BOLT
(TYP)
FLEXIBLE CONNECTION
FLEXIBLE
CONNECTION
ROD
PLASTIC
SECONDARY
DRAIN PAN
TO CONDENSATE DRAIN
CONDENSATE DRAIN CONNECTION
BELOW CONNECTION TO DRAIN PAN.
MUST BE A MINIMUM OF ONE INCH
1.
NOTES:
1/2" PUMPED
CONDENSATE
(REFER TO PLANS
FOR ROUTING)
BALL VALVE
CHECK VALVE
CONDENSATE
RECEIVER
& PUMP
M
IN
UNIT WITH
COOLING COIL
1.
NOTES:
REFER TO PLANS FOR QUANTITY OF PIPING RUNOUTS TO HEAT PUMP UNITS.
R S
R L
R S
R L
R S
R L
RS
RL
GAS PIPE PORT TO
INDOOR UNITS
(TYP)LIQUID PIPE PORT
TO INDOOR UNITS
(TYP)REFRIGERANT LINE
INSULATION (TYP)
SUSPENSION
BRACKET (TYP)
BRANCH SELECTOR/HEAT
RECOVERY BOX
CONTROL BOX
12" MINIMUM SERVICE
CLEARANCE
MINIMUM 18"x18"
SERVICE ACCESS
PLAN VIEW
SHUTOFF VALVE
(TYP)
LIQUID PORT
SUCTION GAS PORT
REFRIGERANT
BALL VALVE
CONDENSATE
DRAINAGE
VRF CONDENSING
UNIT
NOTES:
STAND SHALL MEET ASCE 7 REQUIREMENTS
FOR OVER TURNING.
45°
CHAMFER
GRADE
STEEL STAND
FEET
HEAVY GAUGE
STEEL SUPPORT
STAND
CONCRETE EQUIPMENT
PAD. SEE ARCH DWGS.
1.
24"
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/6
/2
:5 :1
P
M
SAW
DAI
CSA
10/30/19
H8.0
HVAC DETAILS
N.T.S.H8.0
1 SUSPENDED EQUIPMENT DETAIL
N.T.S.H8.0
2 CONDENSATE PUMP DETAIL
N.T.S.H8.0
4 BRANCH SELECTOR BOX PLAN VIEW
N.T.S.H8.0
3 VRF CONDENSING UNIT SUPPORT STAND DETAIL
NIC - DEVICES, WIRING, AND RACEWAY SHALL BE
EXISTING TO REMAIN, UNLESS NOTED OTHERWISE
WORKING CLEARANCE FOR
ELECTRICAL EQUIPMENT
1P 2P 3P 4P A
AB
AC
AFCI
AFF
AIC
AFG
ARCH
ATS
ATC
AV
BAS
BLDG
BDF
C
CATV
CB
CD
CKT
CMT
CP
C.T.
DISC
DO
DWG
(E)
EBB
EC
ELI
(ER)
EWC
FA
FAAP
FACP
FBO
FLA
FT
FTL
GC
GFCI
GND
HP
HV
Hz
IDF
IG
JB
KCMIL
KVA
KW
LED
ONE POLE
TWO POLE
THREE POLE
FOUR POLE
AMPERE
ABOVE CEILING
ABOVE COUNTER
ARC FAULT CURRENT INTERRUPTER
ABOVE FINISHED FLOOR
AMPS INTERRUPTING CURRENT
ABOVE FINISHED GRADE
ARCHITECT
AUTOMATIC TRANSFER SWITCH
AUTOMATIC TEMPERATURE CONTROL SYSTEM
AUDIO VISUAL
BUILDING AUTOMATION SYSTEM
BUILDING
BUILDING DISTRIBUTION FRAME (IT)
CONDUIT
CABLE TELEVISION
CIRCUIT BREAKER
CANDELA
CIRCUIT
EMPTY CONDUIT, WITH PULL STRING
CORD AND PLUG
CURRENT TRANSFORMER
DISCONNECT
DRAWOUT TYPE
DRAWING
EXISTING TO REMAIN
ELECTRIC BASE BOARD HEATER
ELECTRICAL CONTRACTOR
EMERGENCY LIGHTING INTERFACE
EXISTING TO BE RELOCATED
ELECTRIC WATER COOLER
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FURNISHED BY OWNER
FULL LOAD AMPS
FIXED TEMPERATURE
FEED THROUGH LUGS
GENERAL CONTRACTOR
GROUND FAULT CIRCUIT INTERRUPTER
GROUNDED
HORSEPOWER
HIGH VOLTAGE
HERTZ (CYCLE) PER SECOND
INTERMEDIATE DISTRIBUTION FRAME (IT)
ISOLATED GROUND
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILOVOLT AMPERE
KILOWATT
LIGHT EMITTING DIODE
LP
LTG
MCB
MCC
MDP
MDF
(ME)
MISC
MLO
MOA
MOD
MTD
MTG
MTS
(N) N/A
NAC
NEC
N/E
NIC
NL
NTS
OCPD
P
PB
PH
PNL
PVC
PWR
(R)
(RE)
REC
ROR
SCP
SFL
SLC
SWBD
SYS
TC
TEL/DATA
TEL
TTB
TVSS
TYP
UON
UL
V W
WP
WR
XFMR
#1/E5.1
LIGHTING PANEL
LIGHTING
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN DISTRIBUTION PANEL
MAIN DISTRIBUTION FRAME (IT)
MODIFY EXISTING
MISCELLANEOUS
MAIN LUGS ONLY
MULTI-OUTLET ASSEMBLY
MOTOR OPERATED DISCONNECT SWITCH
MOUNTED
MOUNTING
MANUAL TRANSFER SWITCH
NEW
NOT APPLICABLE
NOTIFICATION APPLIANCE CIRCUIT (FAS)
NATIONAL ELECTRICAL CODE
NORMAL/EMERGENCY
NOT IN CONTRACT
NIGHT LIGHT
NUMBER
NOT TO SCALE
OVERCURRENT PROTECTIVE DEVICE
POLE
PULL BOX
PHASE
PANEL
POLYVINYL CHLORIDE CONDUIT
POWER
REMOVE EXISTING
RELOCATE EXISTING
RECESSED
RATE OF RISE
SECURITY CONTROL PANEL
SUB FEED LUGS
SIGNALING LINE CIRCUIT (FAS)
SWITCHBOARD
CONNECTION TO SYSTEMS FURNITURE
TIME CLOCK
TELEPHONE/DATA
TELEPHONE
TELEPHONE TERMINAL BOARD
TRANSIENT VOLTAGE SURGE SUPPRESSION
TYPICAL
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORY
VOLT
WATT
WEATHERPROOF
WEATHER RESISTANT
TRANSFORMER
INDICATES MOUNTED ABOVE CENTER
OR AS NOTED ON DWG.
DETAIL NUMBER/DRAWING NUMBER
ABBREVIATIONS
POWER
ELECTRICAL SYMBOL LIST
BRANCH CIRCUIT WIRING (WHERE SHOWN)
BRANCH CIRCUIT WIRING AND/OR CONDUIT WITH WIRE, CONCEALED IN FLOOR
OR BELOW GRADE.
BRANCH CIRCUIT WIRING AND/OR CONDUIT WITH WIRE, CONCEALED IN CEILING
OR WALL.
BRANCH CIRCUIT WIRING AND/OR CONDUIT WITH WIRE, EXPOSED
BRANCH CIRCUIT WIRING TO PANEL
DENOTES CIRCUIT NUMBER AT PANELBOARD
5RP
DENOTES PANELBOARD IDENTITY (NAME)
OBSERVER
BRANCH CIRCUIT WIRE AND/OR CONDUIT WITH WIRE, TURNING UP TOWARD
OBSERVER
BRANCH CIRCUIT WIRE AND/OR CONDUIT WITH WIRE, TURNING AWAY FROM
NEW WORK
EXISTING TO REMAIN
DEMOLITION
ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (N.E.C.), NATIONAL FIRE
PROTECTION ASSOCIATION (N.F.P.A.), AND APPLICABLE LOCAL CODES.
REFER TO MECHANICAL DRAWINGS TO COORDINATE WITH ALL AREAS OF DEMOLITION & NEW WORK.
VERIFY ALL FIELD CONDITIONS AND LOCATIONS OF EQUIPMENT, LIGHTING, DEVICES, CIRCUITING & FEEDERS, INCLUDING WITH OTHER
TRADES, PRIOR TO ANY ELECTRICAL WORK. DO NOT SCALE DRAWINGS.
CONTRACTOR TO TRACE OUT ALL WIRING, CABLES, CIRCUITING, FEEDERS, & CONTROL WIRING PRIOR TO ANY REMOVAL, RELOCATION, &
MODIFICATIONS. CONTRACTOR TO TAG WITH IDENTIFICATION & MAINTAIN WRITTEN RECORD.
THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AS NECESSARY FOR THE ENTIRETY OF DEMOLITION & CONSTRUCTION PHASES, AND COMPLY WITH UTILITY, STATE, LOCAL, AND REGULATING AUTHORITIES.
REMOVE ALL AFFECTED ELECTRICAL EQUIPMENT, DEVICES, LIGHTING, WIRING & CONDUIT, ETC. TO COORDINATE WITH THE NEW RENOVATIONS & WORK UNLESS OTHERWISE NOTED. WHERE THE DEMOLITION & REMOVAL OR RELOCATION OF SUCH EQUIPMENT AFFECTS THE CONTINUITY OF CIRCUIT(S) WHICH SERVE OTHER ITEMS DOWNSTREAM NOT TO BE REMOVED OR RELOCATED, THE CONTRACTOR SHALL REMOVE THE CIRCUIT WIRING BACK TO THE SOURCE (PANEL, BREAKER, SWITCH, ETC.). PROVIDE NEW WIRING AND RACEWAY, &
CONNECT TO THE UNAFFECTED DOWNSTREAM DEVICE TO MAINTAIN CONTINUITY.
COORDINATE WITH MECHANICAL CONTRACTOR FOR THE REMOVAL OR MODIFICATION OF THEIR EQUIPMENT, DISCONNECT, RECONNECT OR MODIFY CIRCUITING, INTERLOCKING, SWITCHING, ETC. TO COORDINATE WITH THE NEW WORK & ALTERATIONS FOR THE NEXT PHASE.
THE ELECTRICAL CONTRACTOR SHALL, AS PART OF THEIR WORK, PERFORM ALL RELATED DEMOLITION (TO CLEAR THE AREA OF THIS CONTRACT OF EXISTING SYSTEMS OR PARTS THEREOF), MODIFICATIONS, RELOCATION OF SERVICES AND RELATED WORK, INCLUDING NEW
WORK NECESSARY TO COMPLETE THE PROJECT.
ITEMS REMOVED SHALL BE OFFERED TO THE OWNER FOR THEIR USE. IF NOT ACCEPTED BY THE OWNER, DISPOSE OF THE MATERIAL FROM
THE SITE.
EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION AND MODIFICATIONS OF SERVICES, EQUIPMENT AND MATERIALS
RELATING TO EACH TRADE RESPECTIVELY.
ELECTRICAL GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
MISCELLANEOUS
JUNCTION BOX (FLOOR, CEILING, WALL)
PULL BOX
MOTOR
T TRANSFORMER
J J J
PB
CIRCUIT PROTECTION
DISCONNECT SWITCH, UNFUSED TYPE
DISCONNECT SWITCH, FUSED TYPE
PANELBOARDS
SURFACE MOUNTED ELECTRICAL PANELBOARD
RECESSED MOUNTED ELECTRICAL PANELBOARD
SYSTEMS PANEL OR TERMINAL CABINET (AS INDICATED ON DRAWING)
MANUAL MOTOR STARTERS
COMBINATION MOTOR STARTER
M
ENCLOSED CIRCUIT BREAKERCB
TAG
EQUIPMENT CONNECTION
GROUND ROD
XX/##
CIRCUIT NUMBER
CIRCUIT DESIGNATION
PANEL NAME
DUPLEX RECEPTACLE
QUADRAPLEX RECEPTACLE
DUPLEX GROUND FAULT RECEPTACLE
OR AS INDICATED ON DRAWINGS
DUPLEX RECEPTACLE - MOUNTED ABOVE COUNTER HEIGHT, BACKSPLASH,
BACKSPLASH, OR AS INDICATED ON DRAWINGS
DUPLEX GROUND FAULT RECEPTACLE - MOUNTED ABOVE COUNTER HEIGHT,
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :0
P
M
KL
PLB
JH
10/30/19
E0.0
ELECTRICAL COVER SHEET
ELECTRICAL DRAWING SCHEDULE
SHEET
NUMBER SHEET NAME
100% CD
10/30/19
E0.0 ELECTRICAL COVER SHEET ●
E2.1 ELECTRICAL DEMOLITION PLANS ●
E4.1 ELEC POWER & SYSTEMS PLAN - BASEMENT ●
E4.2 ELEC POWER & SYSTEMS PLAN - 1ST FLOOR ●
E4.4 ELECTRICAL POWER & SYSTEMS PLAN - ATTIC ●
E7.1 ELECTRICAL SCHEDULES ●
UP
UP
DN
UP
DN
UP
MOULDERS
DINING RM.
(R) CABINET
UNIT HEATER
(E) WOODEN REVEAL PATHWAY
KITCHEN
(E) DEHUMIDIFIER
(E) UH
(E) UH
(E) UH
(E)PANEL PP
(E)FACP
(E)
PANEL HP
EXISTING CEILING
PATH UP
(E) UNDERGROUND 200A, 240V,
3 PHASE, 3W FROM VISITOR
CENTER BUILDING
(E) 200A/200A/3P
240V SWITCH
NORTHWEST
PARLOR
STAIR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
PANEL CH (E)
WIRE TROUGH
(E)
REMOVE EXISTING
STARTERS & WIRING
FROM TROUGH
ASSOCIATED WITH
MECHANICAL
EQUIPMENT BEING
DEMOLISHED BY
MECHANICAL
CONTRACTOR
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :0
P
M
KL
PLB
JH
10/30/19
E2.1
ELECTRICAL DEMOLITION
PLANS
1/8" = 1'-0"E2.1
1 ELECTRICAL DEMOLITION PLAN - BASEMENT
1/8" = 1'-0"E2.1
2 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR
GENERAL NOTES:
ALL LIGHTING, POWER, EQUIPMENT, SYSTEMS, DEVICES, ETC. ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.
VERIFY ALL FIELD CONDITIONS, LOCATIONS, WIRING, LIGHTING, EQUIPMENT AND DEVICES WITH OTHER TRADES PRIOR TO INSTALLATION OF
ELECTRICAL WORK. DO NOT SCALE DRAWINGS.
CONTRACTOR TO TRACE OUT ALL WIRING, CIRCUITING, FEEDERS & CONTROL WIRING PRIOR TO ANY REMOVAL, RELOCATION &
MODIFICATIONS. CONTRACTOR TO TAG WITH IDENTIFICATION & MAINTAIN WRITTEN RECORD.
REFER TO MECHANICAL DRAWINGS FOR ALL AREAS OF DEMOLITION & NEW WORK.
REMOVE, RELOCATE OR MODIFY ELECTRICAL WORK TO COORDINATE WITH ALTERATIONS AND NEW WORK. WHERE THE REMOVAL OF SUCH EQUIPMENT AFFECTS THE CONTINUITY OF CIRCUIT(S) WHICH SERVE OTHER ITEMS DOWNSTREAM NOT TO BE REMOVED, THE CONTRACTOR SHALL REMOVE THE CIRCUIT WIRING BACK TO THE UPSTREAM DEVICE CLOSEST TO THE SOURCE, OR IF REQUIRED, BACK TO THE SOURCE (PANEL, BREAKER, SWITCH, ETC.). PROVIDE NEW WIRING AND RACEWAY, CONNECT TO THE UNAFFECTED DOWNSTREAM
DEVICE TO MAINTAIN CONTINUITY.
UNLESS OTHERWISE NOTED, UTILIZE EXISTING 240V & 120/240V ELECTRICAL PANELS FOR CIRCUITING EXISTING & NEW ELECTRIC, SYSTEMS
& MECHANICAL. REFER TO NEW WORK PLANS.
WHERE EXISTING ELECTRICAL FEEDERS, WIRING, CONDUIT, LIGHTING FIXTURES, SYSTEM DEVICES OR EQUIPMENT INTERFERES WITH THE REMOVAL OF EXISTING, AND INSTALLATION OF NEW CONSTRUCTION OF ANY TRADE, THE CONTRACTOR SHALL RE-ROUTE THE EXISTING ELECTRICAL FEEDER, WIRING, CONDUIT OR RELOCATE THE EQUIPMENT IN AN APPROVED INSTALLATION OF THE NEW CONSTRUCTION. THE CONTRACTOR SHALL WORK WITH THE BUILDING MAINTENANCE ENGINEER TO IDENTIFY CABLES OR SYSTEMS TO BE RELOCATED.
WHERE THE EXISTING CEILING AND FINISHES ARE BEING REMOVED TO INSTALL NEW FINISHES, THE ELECTRICAL CONTRACTOR SHALL TEMPORARILY REMOVE ANY EXISTING ELECTRIC TO COORDINATE WITH THE RENOVATION AND MODIFICATIONS. REINSTALL ANY EXISTING
ELECTRIC TO REMAIN AT THE NEW FINISH SURFACE AS REQUIRED.
COORDINATE WITH MECHANICAL CONTRACTOR FOR THE REMOVAL OR MODIFICATION OF THEIR EQUIPMENT. DISCONNECT, RECONNECT OR MODIFY CIRCUITING, INTERLOCKING, SWITCHING, ETC. TO COORDINATE WITH NEW WORK & ALTERATIONS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
UP
UP
S
MOULDERS
DINING RM.
KITCHEN
(E) DEHUMIDIFIER
(E) UH
(E) UH
(E) UH
(E)PANEL PP
(E)FACP
(E)
PANEL HP
(E) WOODEN REVEAL
PATHWAY
EXISTING CEILING
PATH UP
(E) UNDERGROUND 200A, 240V,
3 PHASE, 3W FROM VISITOR
CENTER BUILDING
(E) 200A/200A/3P
240V SWITCH
VRF
0-1 BC
VRF
0-2
VRF
0-5
CU
VRF
0-3
VRF
0-4
CP
PP/17
WP WR
PROVIDE WEATHERPROOF HUBBELL
LIGHT, SWITCH & WEATHER
RESISTANT DUPLEX GFCI
RECEPTACLE WITH "WHILE IN USE"
COVER MOUNTED ON UNISTRUT
RACK. CIRCUIT TO EXISTING PANEL
PP-16.
MOD 1 MOD 2
VRF
0-6
COORDINATE LOCATION OF SURFACE
MOUNTED RACEWAY AND BOX WITH COR.
CORE, SLEEVE & SEAL
VERTICAL RACK ON WALL
FOR HVAC & ELECTRIC
SHARED PATHWAY UP
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :1
P
M
KL
PLB
JH
10/30/19
E4.1
ELEC POWER & SYSTEMS
PLAN - BASEMENT
1/4" = 1'-0"E4.1
1 ELECTRICAL POWER & SYSTEMS PLAN - BASEMENT
GENERAL NOTES:
ALL EQUIPMENT & DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED.
VERIFY ALL FIELD CONDITIONS AND LOCATIONS OF EQUIPMENT, DEVICES & WIRING WITH COR, INCLUDING OTHER TRADES PRIOR TO INSTALLATION OF ELECTRICAL WORK. DO NOT SCALE
DRAWINGS.
COORDINATE WITH MECHANICAL CONTRACTOR FOR ALL MECHANICAL WORK, EQUIPMENT,
CHARACTERISTICS, LOCATIONS & QUANTITIES PRIOR TO ANY ROUGH-INS. REFER TO MECHANICAL
DRAWINGS FOR FURTHER INFORMATION.
ELECTRICAL CONTRACTOR TO VERIFY IN FIELD WITH MECHANICAL CONTRACTOR FOR ANY
CONTROLS, SWITCHING & INTERFACING PRIOR TO ANY ROUGH-IN. PROVIDE EMPTY BOXES &
RACEWAYS. POWER CIRCUITS & CONTROL RACEWAYS SHALL FOLLOW MECHANICAL.
WIRE TROUGH, PULL & JUNCTION BOXES ARE SIZED BY THE ELECTRICAL CONTRACTOR TO MEET
FIELD CONDITIONS & CODE REQUIREMENTS.
REFER TO ELECTRICAL CONNECTION SCHEDULE ON DRAWING E7.1 FOR MECHANICAL EQUIPMENT &
CIRCUITING. REFER MECHANICAL DRAWINGS & SCHEDULES FIR EQUIPMENT QUANTITIES &
LOCATIONS.
ELECTRICAL CONTRACTOR SHALL SLEEVE & SEAL ALL CONDUITS AT ALL POINTS OF PENETRATION INTO EARTH, MASONRY, OR STRUCTURE IN BUILDING. PROVIDE FIRE RATED THRU-WALL, CEILING &
FLOOR SEALS TO ASSURE LEAK FREE INSTALLATION AND PREVENTION OF GAS OR OTHER FUME
SEEPAGE INTO BUILDING.
1.
2.
3.
4.
5.
6.
7.
DN
UP
NORTHWEST
PARLOR
STAIR
SOUTHWEST
PARLOR
DINING ROOM
KITCHEN
PANEL CH
(E)
WIRE TROUGH
(E)
VRF
1-1
SHARED PATHWAY UP
J
120V CKT FOR
TOUCH SCREEN
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :1
P
M
KL
PLB
JH
10/30/19
E4.2
ELEC POWER & SYSTEMS
PLAN - 1ST FLOOR
1/4" = 1'-0"E4.2
1 ELECTRICAL POWER & SYSTEMS PLAN - FIRST FLOOR
GENERAL NOTES:
ALL EQUIPMENT & DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED.
VERIFY ALL FIELD CONDITIONS AND LOCATIONS OF EQUIPMENT, DEVICES & WIRING WITH COR, INCLUDING OTHER TRADES PRIOR TO INSTALLATION OF ELECTRICAL WORK. DO NOT SCALE
DRAWINGS.
COORDINATE WITH MECHANICAL CONTRACTOR FOR ALL MECHANICAL WORK, EQUIPMENT,
CHARACTERISTICS, LOCATIONS & QUANTITIES PRIOR TO ANY ROUGH-INS. REFER TO MECHANICAL
DRAWINGS FOR FURTHER INFORMATION.
ELECTRICAL CONTRACTOR TO VERIFY IN FIELD WITH MECHANICAL CONTRACTOR FOR ANY
CONTROLS, SWITCHING & INTERFACING PRIOR TO ANY ROUGH-IN. PROVIDE EMPTY BOXES &
RACEWAYS. POWER CIRCUITS & CONTROL RACEWAYS SHALL FOLLOW MECHANICAL.
WIRE TROUGH, PULL & JUNCTION BOXES ARE SIZED BY THE ELECTRICAL CONTRACTOR TO MEET
FIELD CONDITIONS & CODE REQUIREMENTS.
REFER TO ELECTRICAL CONNECTION SCHEDULE ON DRAWING E7.1 FOR MECHANICAL EQUIPMENT &
CIRCUITING. REFER MECHANICAL DRAWINGS & SCHEDULES FIR EQUIPMENT QUANTITIES &
LOCATIONS.
ELECTRICAL CONTRACTOR SHALL SLEEVE & SEAL ALL CONDUITS AT ALL POINTS OF PENETRATION INTO EARTH, MASONRY, OR STRUCTURE IN BUILDING. PROVIDE FIRE RATED THRU-WALL, CEILING &
FLOOR SEALS TO ASSURE LEAK FREE INSTALLATION AND PREVENTION OF GAS OR OTHER FUME
SEEPAGE INTO BUILDING.
1.
2.
3.
4.
5.
6.
7.
303 304BC
VRF
2-6
VRF
2-5
VRF
2-1
VRF
2-2
VRF
2-3
VRF
2-4
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :1
P
M
KL
PLB
JH
10/30/19
E4.4
ELECTRICAL POWER &
SYSTEMS PLAN - ATTIC
1/4" = 1'-0"E4.4
1 ELECTRICAL POWER & SYSTEMS PLAN - ATTIC
GENERAL NOTES:
ALL EQUIPMENT & DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED.
VERIFY ALL FIELD CONDITIONS AND LOCATIONS OF EQUIPMENT, DEVICES & WIRING WITH
ARCHITECT, INCLUDING OTHER TRADES PRIOR TO INSTALLATION OF ELECTRICAL WORK. DO NOT
SCALE DRAWINGS.
COORDINATE WITH MECHANICAL CONTRACTOR FOR ALL MECHANICAL WORK, EQUIPMENT,
CHARACTERISTICS, LOCATIONS & QUANTITIES PRIOR TO ANY ROUGH-INS. REFER TO MECHANICAL
DRAWINGS FOR FURTHER INFORMATION.
ELECTRICAL CONTRACTOR TO VERIFY IN FIELD WITH MECHANICAL CONTRACTOR FOR ANY
CONTROLS, SWITCHING & INTERFACING PRIOR TO ANY ROUGH-IN. PROVIDE EMPTY BOXES &
RACEWAYS.
WIRE TROUGH, PULL & JUNCTION BOXES ARE SIZED BY THE ELECTRICAL CONTRACTOR TO MEET
FIELD CONDITIONS & CODE REQUIREMENTS.
REFER TO ELECTRICAL CONNECTION SCHEDULE ON DRAWING E7.1 FOR MECHANICAL EQUIPMENT &
CIRCUITING. REFER MECHANICAL DRAWINGS & SCHEDULES FIR EQUIPMENT QUANTITIES &
LOCATIONS.
ELECTRICAL CONTRACTOR SHALL SLEEVE & SEAL ALL CONDUITS AT ALL POINTS OF PENETRATION INTO EARTH, MASONRY, OR STRUCTURE IN BUILDING. PROVIDE FIRE RATED THRU-WALL, CEILING &
FLOOR SEALS TO ASSURE LEAK FREE INSTALLATION AND PREVENTION OF GAS OR OTHER FUME
SEEPAGE INTO BUILDING.
1.
2.
3.
4.
5.
6.
7.
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF 25
REPLACE RADIANT HEATING SYSTEM AT
IRONMASTER'S MANSION
100% CONSTRUCTION DOCUMENT DRAWINGS
HOFU 237580
/3
/2
:4 :1
P
M
KL
PLB
JH
10/30/19
E7.1
ELECTRICAL SCHEDULES
ELECTRICAL CONNECTION SCHEDULE- MECHANICAL EQUIPMENT
TAG NUMBER
ELECTRICAL CHARACTERISTICS LOCAL DISCONNECT DEVICE STARTER WIRING
REMARKS V/PH/HZ MCA MOCP KW HP
NONFUSED
SWITCH
FUSIBLE
SWITCH
MAN MOTOR SWITCH
DIV TYPE SIZE
COMBINATION TYPE ACCESSORIES
DIV WIRE PANEL
CIRCUIT
NUMBERW/O OL W/ OL SWITCH MCP HOA PILOT
BC 1 240/1/60 .47 15A X 26 2 #12, 1 #12 GND. - 3/4"C. HP 10,12
BC 2 240/1/60 .47 15A X 26 2 #12, 1 #12 GND. - 3/4"C. HP 14,16
CP 1 CORD & PLUG 120/1/60 FRACTIONAL 26 2 #12, 1 #12 GND. - 3/4"C. PP 17
CU 1 MODULE 1 240/3/60 33 45A 60/40/3 26 3 #6, 1 #10 GND. - 1"C. CH 1,3,5
CU 1 MODULE 2 240/3/60 33 45A 60/40/3 26 3 #6, 1 #10 GND. - 1"C. CH 7,9,11
VRF 0-1 240/1/60 1.2 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 13,15
VRF 0-2 240/1/60 3 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 13,15
VRF 0-3 240/1/60 .38 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 17,19
VRF 0-4 240/1/60 3 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 21,23
VRF 0-5 240/1/60 1.2 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 25,27
VRF 0-6 240/1/60 3 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 21,23
VRF 1-1 240/1/60 .38 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 6,8
VRF 2-1 240/1/60 1.2 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 10,12
VRF 2-2 240/1/60 1.2 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 14,16
VRF 2-3 240/1/60 2.5 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 18,20
VRF 2-4 240/1/60 2.5 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 22,24
VRF 2-5 240/1/60 1.2 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 26,28
VRF 2-6 240/1/60 2.5 15A X 26 2 #12, 1 #12 GND. - 3/4"C. CH 2,4
SCHEDULE NOTES:
TOTAL KVA B: 3.68 TOTAL CONNECTED AMPS: 38.15 A
TOTAL KVA A: 4.44 TOTAL CONNECTED KVA: 8.12 KVA
17 20 A 1 (N) RCPTL - CP-1 & TOUCH SCREEN 0.06 0.00 SPACE WITH BUS -- -- 18
15 20 A 1 (E) RCPTL - RM 002 0.36 0.20 (N) LTG & GFCI OUTDOOR 1 20 A 16
13 20 A 1 (E) FIRE ALARM & SECURITY 0.30 0.54 (E) RCPTL - RM 004, 005 1 20 A 14
11 20 A 1 (E) RCPTL - RM 003 0.36 0.72 (E) RCPTL - RM 208, 209, 304 1 20 A 12
9 20 A 1 (E) LTG & RCPTLS 0.50 0.54 (E) RCPTL - RM 201, 204 1 20 A 10
7 20 A 1 (E) RCPTL & LTG - BASEMENT 0.50 0.54 (E) RCPTLS - 101-103 1 20 A 8
5 20 A 1 (E) LTG - BASEMENT 0.50 1.00 (E) RCPTL - DEDICATED RM 204 1 20 A 6
3 20 A 1 (E) BARN & STORE 1.00 0.00 -- -- -- 4
1 20 A 1 (E) BARN & STORE 1.00 0.00 MAIN CIRCUIT BREAKER 2 100 A 2
CKT TR P DESCRIPTION A B A B DESCRIPTION P TR CKT
LOCATION: 003
ISOL. GRD. BUS:
GRD. BUS: X
10 KAIC NEUT. BUS X
MAINS: 2P/100A
208/120V 1 PHASE 3 WIRE MAIN BUS RATING: 100 A
ELECTRICAL PANEL SCHEDULE (E) PANEL PP
SCHEDULE NOTES:
TOTAL KVA C: 7.85
TOTAL KVA B: 7.89 TOTAL CONNECTED AMPS: 63.17 A
TOTAL KVA A: 10.45 TOTAL CONNECTED KVA: 26.18 KVA
17 -- -- -- 0.00 0.00 SPACE WITH BUS -- -- 18
15 -- -- -- 0.00 0.05 -- -- -- 16
13 100 A 3 MAIN CIRCUIT BREAKER 0.00 0.05 (N) BC-2 2 15 A 14
11 -- -- -- 2.60 0.05 -- -- -- 12
9 30 A 2 (E) UH - RM 005 2.60 0.05 (N) BC-1 2 15 A 10
7 -- -- -- 2.60 2.60 -- -- -- 8
5 30 A 2 (E) UH - RM 003 2.60 2.60 (E) UH - RM 004 2 30 A 6
3 -- -- -- 2.60 2.60 -- -- -- 4
1 30 A 2 (E) UH - RM 001 2.60 2.60 (E) UH - RM 002 2 30 A 2
CKT TR P DESCRIPTION A B C A B C DESCRIPTION P TR CKT
LOCATION: 003
ISOL. GRD. BUS:
GRD. BUS: X
10 KAIC NEUT. BUS X
MAINS: 3P/100A
240V 3 PHASE 3 WIRE MAIN BUS RATING: 100 A
ELECTRICAL PANEL SCHEDULE (E) PANEL HP
SCHEDULE NOTES:
TOTAL KVA C: 7.92
TOTAL KVA B: 8.66 TOTAL CONNECTED AMPS: 59.27 A
TOTAL KVA A: 7.97 TOTAL CONNECTED KVA: 24.55... KVA
29 -- -- SPACE WITH BUS 0.00 0.00 SPACE WITH BUS -- -- 30
27 -- -- -- 0.12 0.12 -- -- -- 28
25 15 A 2 VRF-0-5 0.12 0.12 VRF-2-5 2 15 A 26
23 -- -- -- 0.65 0.24 -- -- -- 24
21 15 A 2 VRF-0-4 & VRF-0-6 0.65 0.24 VRF-2-4 2 15 A 22
19 -- -- -- 0.04 0.24 -- -- -- 20
17 15 A 2 VRF-0-3 0.04 0.24 VRF-2-3 2 15 A 18
15 -- -- -- 0.48 0.12 -- -- -- 16
13 15 A 2 VRF-0-1 & VRF-0-2 0.48 0.12 VRF-2-2 2 15 A 14
11 -- -- -- 3.30 0.12 -- -- -- 12
9 -- -- -- 3.30 0.12 VRF-2-1 2 15 A 10
7 50 A 3 CU-1 (MODULE 2) 3.30 0.04 -- -- -- 8
5 -- -- -- 3.30 0.04 VRF-1-1 2 15 A 6
3 -- -- -- 3.30 0.24 -- -- -- 4
1 50 A 3 CU-1 (MODULE 1) 3.30 0.24 VRF-2-6 2 15 A 2
CKT TR P DESCRIPTION A B C A B C DESCRIPTION P TR CKT
LOCATION: KITCHEN 105
ISOL. GRD. BUS:
GRD. BUS: X
10 KAIC NEUT. BUS X
MAINS: 3P/200A
240V 3 PHASE 3 WIRE MAIN BUS RATING: 200 A
ELECTRICAL PANEL SCHEDULE (E) PANEL CH
GENERAL NOTES:
FACTORY SUPPLIED EQUIPMENT CONTROL PANEL WITH CONTROL
TRANSFORMERS, ETC. U.O.N.
PROVIDE HACR CIRCUIT BREAKERS FOR HEATING, AIR CONDITIONING &
REFRIGERATION EQUIPMENT UNLESS OTHERWISE RECOMMENDED BY
THE EQUIPMENT MANUFACTURER. PROVIDE STANDARD CIRCUIT
BREAKER IN PANEL FOR UNIT EQUIPMENT WITH FUSE DISCONNECT
SWITCH.
REFER MECHANICAL & PLUMBING DRAWINGS FOR ACTUAL PHYSICAL
LOCATION & QUANTITIES OF EQUIPMENT LISTED IN SCHEDULE.
COORDINATE ELECTRICAL WORK WITH MECHANICAL, PLUMBING, FIRE
PROTECTION AND CONTROLS CONTRACTORS FOR ALL EQUIPMENT
CHARACTERISTICS, CONTROL/INTERLOCKING CONDUIT ROUTING AND
LOCATIONS PRIOR TO ANY ROUGH-INS. CONTROL AND INTERLOCKING
WIRING (INCLUDING TERMINATIONS), AND CONTROL TRANSFORMERS
ARE BY MECHANICAL, PLUMBING OR CONTROLS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .