ADDITIONAL REQUIREMENTS FOR HC101320QA116

REMARKS:

1. VENDOR MUST MEET SVC DATE.

2. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: SINGLE-MODE

INTERFACE REQUIREMENT/INTERFACE DATA RATE:

LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR,

2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991

(R2003). ALL OPTIONS DEFINED SC CONNECTOR,

SINGLE-MODE FIBER PER ANSI T1.105.06-2002

(SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).

(B) LINE MUST REMAIN FULLY OPERATIONAL AND

AVAILABLE

TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT

LEAST 99.5% OR BETTER.

(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR

TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.

(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO

BE ENGINEERED INTO CIRCUIT.

(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS

(F) NO NETWORK INTERFACE UNIT.

(G) DEDICATED PATH.

(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO

ASSIST IN ANY CIRCUIT OUTAGES.

(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY

END TO END TEST ON THE 2.5 WAVE SERVICE IAW ITU

STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST

SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST

RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE

ACCEPTING AUTHORITY FOR REVIEW.

(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL

CENTER OF THIS 2.5GB WAVE SERVICE.

(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED

ON

BEHALF OF THE GOVERNMENT BY THE CONUS GNOSC:

PRI POC: CONTACT: MIKE REEVES

(C) 618-220-8973 (D) 770-8973

ALT POC: CONTACT: DAMION SCANDRICK

(C) 618-220-9634 (D) 770-9634

ALT POC: CONTACT: AARON SMITH

(C) 618-220-9820 (D) 770-9820

ALT POC: CONTACT: BOB RISKY

(C) 618-220-8632 (D) 770-8632

ALT POC: ORGANIZATIONAL NUMBER

(C) 618-220-8691 (D) 770-8691

(L) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT

NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE

ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT

ACCEPTING SERVICE. INSIDE WIRING MUST BE

COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR

TO TURNUP TO THE GOVERNMENT.

3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND

MAINTENANCE OF 2.5GB WAVE SERVICE IAW UNIQUE

INSTALLATION FACTORS.

4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE

INSTALLATION FACTORS.

5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS

IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT

BOTH USER LOCATIONS. IF UNABLE TO REACH SITE POC'S

CONTACT KEN DIEF OR RAY BURKE FOR ASSISTANCE AT:(301)

225-2416/2550.

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS:

LINE RATE: 2.5GB.

LINE CODE: NRZ

FRAME FORMAT: SCRAMBLED IAW

ANSI T1.104-1991 (R2003)

1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE CIRCUITS

SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK

TEST BY THE CONUS GNOSC AT SCOTT AFB, IL.

PRIMARY: (C) 618-220-8691 (D) 770-8691

2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED

SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS

ON A MONTHLY BASIS.

PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:

NON-DIVERSE/NON-PROTECTED

AVAILABILITY: GREATER THAN OR EQUAL TO 99.5% OR BETTER.

MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):

LESS THAN OR EQUAL TO 9

% ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005

% SEVERELY ERRORED SECONDS (SES): LESS THAN OR

EQUAL TO 0.00035

BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN

OR EQUAL TO 5 X 10-6

BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP):

LESS THAN OR EQUAL TO 1 PER 72 HOURS

JITTER SEE NOTE 1 (JITTER)

BER: LESS THAN OR EQUAL TO 1X10-12

DELAY (ONE WAY): * LESSER OF 10 MSEC OR

(0.01 X D MSEC) * WHERE "D" IS THE SDP TO SDP

TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT

CIRCLE, IN KILOMETERS.

3. ROUND TRIP DELAY (RTD) SHALL BE LESS THAN OR EQUAL

TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION.

THE GOVERNMENT ACCEPTING

AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP

AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE

CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO

IMMEDIATELY IN WRITING.

THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED

TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE

DELIVERY POINTS (SDP'S) FROM TSR SF02FEB185936;

MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE

INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE

LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A

MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM

TSR SG02FEB185936.

6. TELECOMM PROVIDER MUST PROVIDE DISA COLOR POWERPOINT

DRAWINGS FORTECHNICAL REVIEW SHOWING THE ROUTES FROM

THE COMMERCIAL DEMARCS TO THE SUPPORING CENTRAL

OFFICES AND OR WIRING CENTERS ENSURING THE PHYSICAL

END TO END DIVERSITY REQUIREMENTS ARE BEING MET.

L. COMPLETION REPORT: STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO

WILL SUBMIT COMPLETION REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3

FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED TO ORIGINATOR

AND ALL ADDRESSEES OF THIS TSO.

M. DRAWINGS ALSO TO INCLUDE SEPARATION DISTANCES,

TOTAL

FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY

MUST PROVIDE COLOR CODED MAPS AND MUST BE RED LINED

SHOWING HOW THE CIRCIT WILL BE ROUTED END TO END FROM

THE CUSTOMER A LOCATON TO THE CUSTOMER Z LOCATION.

7. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.

8. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.

9. 2.5GB WAVE SERVICE MUST BE ENGINEERED/PROVISIONED IN

SUCH A WAY THAT THE GOVERNMENT CAN CHANGE/REVISE

CHANNELIZATION WITHOUT TELECOMM PROVIDER INTERVENTION.

A. NOTE 1 (JITTER).: IN A STEADY-STATE CONDITION,

THE PATTERN OF SYNCHRONOUS TRANSPORT SIGNAL (STS)

POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH

THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO

MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH

THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI

T1.105.03-1994) THAN THE POINTER ADJUSTMENT

SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING

TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2

TIMES PER DAY), THE PATTERN OF STS POINTER

ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE

SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR

OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME

INTERVAL ERROR (MTIE) OVER A PERIOD OF S SECONDS,

OR WANDER, SHALL NOT EXCEED (.01S + 10000)

NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.

B. WAVELENGTH TRANSMISSION SERVICES:

WAVELENGTH TRANSMISSION SERVICES FOR RATES

OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T

RECOMMENDATIONS G.709(03/2003), G.707(12/03),

G.957(03/06), G.692(10/98) & TELCORDIA GR253-NS6.

THE PROVIDED WAVELENGTH TRANSMISSION SERVICE

SHALL NOT INHIBIT GOVERNMENT OPERATION OF

UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS

SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP,

ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE

WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL

PASS ALL PAYLOAD, PATH AND LINE OVERHEAD BYTES

TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT

MONITORING SDP TO SDP. THERE SHALL NOT BE ANY

LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP

AND SDP.

C. 2.5GB WAVE SERVICE MUST BE TERMINATED TO THE LINE

SIDE OF THE FIBER TERMINATING PATCH PANEL

INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE AT

EBBING ANGB, AND THE FIBER TERMINATING PATCH PANEL

INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE

INSTALLED AT TINKER AFB.

D. TELECOMM PROVIDER MUST CONTACT DISA CONUS TIER-II

ODXC ENGINEERING UPON RECEIPT OF A VALID TSO TO

ESTABLISH THE COORDINATION AND ACTIVATION PROCESS.

10. ONCE TELECOMM PROVIDER HAS COMPLETED INSIDE

WIRING FROM THE DWDM EQUIPMENT SUITE TO THE

GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH

LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS

(DB LOSS) ARE ADJUSTED TO READ -5 TO -13 LOSS.

ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE

NOTICE OF COMPLETION (NOC) SENT TO DITCO.

***THE VENDOR MUST TERMINATE 2.5GB WAVE SERVICE AT

BOTH LOCATIONS IAW UNIQUE INSTALLATION FACTORS.***

11. THE 2.5GB WAVE SERVICE MUST PASS A DOCUMENTED

SATISFACTORY 72 HOUR END TO END TEST IAW ITU

STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.

12. CROSS REFERENCE CCSD IS "XXXX6NG3".