IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 6/26/2018
SUBJECT: HC101318QA812-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: THE PURPOSE OF THIS AMENDMENT IS TO CORRECT THE SERVICE
DELIVERY POINT (SDP) ADDRESSES FOR LOCATION A AND LOCATION Z, AS STATED IN THE
LOCATIONS SECTION OF THE SOLICITATION. WHILE THE ORIGINAL SOLICITATION DATED
6/5/18 CORRECTLY LISTED THE LOC A DEMARK AND LOC Z DEMARK, IT INCORRECTLY
LISTED THE SDP ADDRESSES FOR THE A LOC AND Z LOC.
1. A LOC SDP ADDRESS IS HEREBY CHANGED TO READ AS BLDG 941, C-WING, 170 W.
SELFRIDGE STREET, MAXWELL AFB, AL 36112.
2. Z LOC SDP ADDRESS IS HEREBY CHANGED TO READ AS BLDG 857, ROOM 123, 401 E.
MOORE AVENUE, MAXWELL AFB, AL 36114.
RECAP:
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN THE NEW START OF A 10GB
ETHERNET IP BACKBONE CIRCUIT BETWEEN THE J-PE ROUTER (UJEWMAX030) IN BLDG
941, C-WING, 170 W. SELFRIDGE ST, MAXWELL AFB, AL AND J-PE ROUTER (UJEWGUN030)
IN BLDG 857, RM 123, 401 EAST MOORE AVENUE, MAXWELL AFB GUNTER ANNEX, AL. **SEE
UNIQUE INSTALL FACTORS.**
A. ESTABLISH TSP.
B. IN SUPPORT OF MPLS IMPLEMENTATION (D300).
C. CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS.
2. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
3. THE SERVICE DATE TO BE MET IS: 02 OCT 18 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
4. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04. QUOTES
SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
HC101318QA812-0001
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS
UNAVAILABLE OR QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING
MAILBOX:
DISA.SCOTT.DITCO.MBX.VENDOR-QUOTES@MAIL.MIL
QUOTES MUST BE UPLOADED TO IDEAS. IN THE EVENT IDEAS IS UNAVAILABLE OR
QUOTES FAIL TO UPLOAD, QUOTES MAY BE SENT TO THE FOLLOWING MAILBOX:
disa.scott.ditco.mbx.pl8211@mail.mil
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QB024/ TSR# RU03OCT175637 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR# RU03OCT175637; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR# RU03OCT175637.
6. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
7. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) WITH LOCAL
POCS AT EACH GOVERNMENT SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM,
CONTRACTORS CONDUCT PHONE SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF
THE WORK TO BE PERFORMED IN DETERMINING THEIR PRICE STRATEGY.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU27SEP175587A
4. CCSD: XXXXBBZ8
Z. DITCO CONTACT:
Christopher OConnor
618-229-9712 christopher.t.oconnor2.civ@mail.mil
Paul A. Heard
DITCO Contracting Officer
Add the following:
LOCATION OF TERMINATION A:
ADDRESS: BLDG 941
170 W. SELFRIDGE STREET
MAXWELL AFB, AL 36112
ROOM: C-WING; (FL) 1
LOCATION: CCC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: ELECTRICAL: 10GBASE-LR; PHYSICAL: SC; 10GBASE-LR
DEMARK: BLDG 942, ROOM 115, OPEN BAY FRAME ROOM
101 WEST KIRKPATRICK AVENUE
MAXWELL AFB, AL 36112-6610
PRI: GLEN ARMAND, D493-2704/2707, C334-953-2704/2707
EMAIL: GLEN.ARMAND.CTR@US.AF.MIL
NPA/NXX: 334/953
UNIQUE INSTALLATION FACTORS: (1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE) COMMERCIAL CARRIER SYSTEM (LOCAL
EXCHANGE CARRIER) PORT: BY LOCAL CARRIER
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE JUNIPER MX-240 ROUTER SUITE
(UJEWMAX030) BLDG 941, ROOM C-WING TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE
FIBER DISTRIBUTION PANEL BLDG 942, ROOM 115 USING SINGLE MODE FIBER. COORDINATE TYPE CONNECTORS
TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER SUITE BLDG 941, ROOM C-WING TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG
942, ROOM 115.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
JUNIPER MX-240 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: (PRI) MR. GLEN ARMAND;
(EMAIL) GLEN.ARMAND@US.AF.MIL; (C) 334-953-2704; (D) 493-2704
(ALT) MR. THOMAS LOCKE;
(EMAIL) THOMAS.LOCKE.CTR@US.AF.MIL; (C) 334-953-2032; (D) 493-2032
Add the following:
LOCATION OF TERMINATION B:
ADDRESS: BLDG 857
401 EAST MOORE AVE
MAXWELL AFB GUNTER ANNEX, AL 36114
ROOM: 123
LOCATION: CCC
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: ELECTRICAL: 10GBASE-LR; PHYSICAL: SC; 10GBASE-LR
DEMARK: BLDG 859, DIAL CENTRAL OFFICE (DCO)
325 EAST MOORE DRIVE
GUNTER ANNEX, AL 36114-3001
PRI: MYRON MILLER, D322-819-3286, C334-819-3286
EMAIL: MYRON.L.MILLER4.CIV@MAIL.MIL
NPA/NXX: 334/416
UNIQUE INSTALLATION FACTORS: (1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE,
SINGLE-MODE, 1310NM, TELCO
(2) TELCO MULTIPLEX (COMMERCIAL FIBER POINT OF PRESENCE)
COMMERCIAL CARRIER SYSTEM (LOCAL EXCHANGE CARRIER) PORT: BY LOCAL CARRIER
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF THE SERVICE FROM THE LINE SIDE OF
THE DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE CISCO ASR-9010 ROUTER SUITE
(UJEWGUN030) BLDG 857, RM 123 TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF PRESENCE FIBER
DISTRIBUTION PANEL BLDG 859, RM DCO USING SINGLE MODE
FIBER. COORDINATE TYPE CONNECTORS TO BE USED FOR TERMINATION TO THE DISA PROVIDED PATCH PANEL.
B. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEYS FOR EXACT CABLE FT. FROM THE DISA PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER SUITE BLDG 857, RM 123 TO THE COMMERCIAL FIBER POINT OF PRESENCE BLDG 859, RM
DCO.
C. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL INSTALLED IN THE
CISCO ASR-9010 ROUTER TO THE COMMERCIAL DEMARC LOCATION WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE
AND MUST BE CONTINUOUS.
D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR
TO SITE SURVEYS OR INSTALLATIONS.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: (PRI) MR. MYRON L MILLER; (C) 334-416-6178; (D) 596-6178
(EMAIL) DISA.MONTGOMERY.ESD.LIST.MON-NODE-SITE-COORDINATOR@MAIL.MIL;
(EMAIL) MYRON.L.MILLER4.CIV@MAIL.MIL
ALT: CALEB GUIN; D322-819-3189; C334-819-3189
EMAIL: CALEB.S.GUIN.CTR@MAIL.MIL
ALT: HELP DESK 24 HOUR CONTACT
D850-0032; C844-347-2457
ORG EMAIL: DISA.MAXWELL.OPM.LIST.OPM41-NODE-SITE-COORDINATOR@MAIL.MIL
File details come from the government source that posted it.