CIRCUIT PARAMETERS FOR SOLICITATION HC101318QA812
CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL
HANDOFF-10GB ETHERNET-LAN-PHY-SINGLE MODE FIBER), 802.3AE,
1310NM. "SC" CONNECTORS.
(B) COMMITTED INFORMATION RATE (CIR) - 10GB.
(C) 10GB ETHERNET - LAN-PHY INTERFACE REQUIRED AT COMMERCIAL
DEMARC AT THE A AND Z LOCATIONS.
(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM
TRANSMISSION UNIT (MTU) OF 9192 OCTETS (BYTES).
(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH
(F) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT.
(G) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24
HOURS IAW ITU-T.Y.1564 BENCH MARKING CONFIGURATION AND
PERFORMANCE OF ETHERNET SERVICE. NOTE-ETHERNET FRAME SIZE
DESIGNATOR 'H' (MTU) IS EQUAL TO 9192 BYTES.
(H) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS
24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR
BETTER.
(I) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT
OF TROUBLE.
(J) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN
ANY CIRCUIT OUTAGES.
(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(L) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE
AND ADMINISTRATION MONITORING OF ETHERNET CIRCUIT IAW
ITU-T-Y.1731.
(M) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE
GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND
IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-220-8627 (D)
770-8627.
(N) VENDOR MUST PROVIDE:
1. THE LONG-HAUL CIRCUIT NO. AND LEC CKT ID'S AS APPLICABLE
TO THE DISA IE161 PROGRAM OFFICE PRIOR TO TURN UP TO THE
GOVERNMENT. PRIMARY: KEN DIEFFENDERFER (301) 225-2416
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF 10GBE SERVICE IAW THE UNIQUE INSTALLATION
FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION
FACTORS.
4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN
ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER
LOCATIONS.
5. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY
PHONE TO THE DISA GOC IP BACKBONE ENGINEERING AND
IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C)
618-220-9950, (D)770-9950 TOLL FREE: 855-868-9950
6. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW
DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON
SUBMISSION IS AVAILABLE AT