Testing Requirements for Solicitation HC101317QA905

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.488GB/ 20 PPM. LINE

CODE: OPTIC FRAME FORMAT: SONET/STS-48C

1. TEST AND ACCEPTANCE:

FIBER OPTIC OC-48C CIRCUITS SHALL PASS A FULLY DOCUMENTED

SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL.

PRIMARY: (C) 618-229-8691 (D) 779-8691

2. TESTING PARAMETERS AND THRESHOLDS:

THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST

AND ACCEPTANCE TESTING. ERROR PERFORMANCE (AVAILABILITY, SES, DM,

EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED AND

RECORDED OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING

INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU

RECOMMENDATION G.826 AND M.2100.

3. ERROR PERFORMANCE:

ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER

THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN

99.5% OR BETTER SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN

0.02% DEGRADED MINUTES (DM) SHALL BE LESS THAN 0.2% ERROR FREE

SECONDS (EFS) SHALL BE GREATER THAN 99%

4. LOSS OF BIT COUNT INTEGRITY (LBCI):

LOSS OF BIT COUNT INTEGRITY SHALL BE MONITORED ONLY BY THE

FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN DETECT AND

MEASURE THE OCCURRENCE OF THE INSERTION OR DELETION OF ONE OR

MORE BITS INTO THE DIGITAL BIT STREAM, ON MANY MANUFACTURERS BERT

TEST EQUIPMENT THIS IS MONITORED USING THE "PATTERN SLIP"

PARAMETER WHERE EVERY OCCURRENCE OF A PATTERN SLIP "EVENT" MARKS

THE OCCURRENCE OF A LBCI (RATHER THAN THE RAW TOTAL NUMBER OF

PATTERN SLIPS ACCUMULATED OVER A TESTING INTERVAL)

5. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE

GREATER THAN 24 HOURS.

6. ROUND TRIP DELAY (RTD):

THE ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL BE

MEASURED IN MILLISECONDS FROM THE CUSTOMERS SERVICE DELIVERY

POINT (SDP) SITE-A TO THE CUSTOMERS SERVICE DELIVERY POINT

(SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10

MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE

GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD ONLY IF

SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE TWO END

LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE RIGHT TO

REJECT A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT WRITTEN

JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE

FIBER MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED

INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL

LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE

RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN

WITH THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO

IMMEDIATELY IN WRITING.

7. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED

COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE

SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1

BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE

ON SUBMISSION IS AVAILABLE AT

HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON

"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

8. COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.

GOVERNMENT BYDISA GOC IP B/D312-770-8627,C001-618-220-86 WHO

WILL SUBMIT A COMPLETION REPORT IAW DISAC 310-130-1, CHAP 2 OF

DISAC 310-70-1, CHAP 8. REPORT WILL BE ADDRESSED TO THE

ORIGINATOR AND ALL ADDRESSEES OF THIS TSO.

9. TEST & ACCEPTANCE INSTRUCTIONS: ALL EQUIPMENT AND CIRCUIT

PROBLEMS WILL BE REPORTED BY PHONE TO DISA GOC IP BACKBONE

ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C)

618-220-9950(D) 770-9950; TOLL FREE: 855-868-9950

10. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO

350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS

AVAILABLE AT. CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE

COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."

File details come from the government source that posted it.