Testing Requirements for Solicitation HC101317QA905
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.488GB/ 20 PPM. LINE
CODE: OPTIC FRAME FORMAT: SONET/STS-48C
1. TEST AND ACCEPTANCE:
FIBER OPTIC OC-48C CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL.
PRIMARY: (C) 618-229-8691 (D) 779-8691
2. TESTING PARAMETERS AND THRESHOLDS:
THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST
AND ACCEPTANCE TESTING. ERROR PERFORMANCE (AVAILABILITY, SES, DM,
EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED AND
RECORDED OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING
INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU
RECOMMENDATION G.826 AND M.2100.
3. ERROR PERFORMANCE:
ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER
THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN
99.5% OR BETTER SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN
0.02% DEGRADED MINUTES (DM) SHALL BE LESS THAN 0.2% ERROR FREE
SECONDS (EFS) SHALL BE GREATER THAN 99%
4. LOSS OF BIT COUNT INTEGRITY (LBCI):
LOSS OF BIT COUNT INTEGRITY SHALL BE MONITORED ONLY BY THE
FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN DETECT AND
MEASURE THE OCCURRENCE OF THE INSERTION OR DELETION OF ONE OR
MORE BITS INTO THE DIGITAL BIT STREAM, ON MANY MANUFACTURERS BERT
TEST EQUIPMENT THIS IS MONITORED USING THE "PATTERN SLIP"
PARAMETER WHERE EVERY OCCURRENCE OF A PATTERN SLIP "EVENT" MARKS
THE OCCURRENCE OF A LBCI (RATHER THAN THE RAW TOTAL NUMBER OF
PATTERN SLIPS ACCUMULATED OVER A TESTING INTERVAL)
5. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE
GREATER THAN 24 HOURS.
6. ROUND TRIP DELAY (RTD):
THE ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL BE
MEASURED IN MILLISECONDS FROM THE CUSTOMERS SERVICE DELIVERY
POINT (SDP) SITE-A TO THE CUSTOMERS SERVICE DELIVERY POINT
(SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10
MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE
GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD ONLY IF
SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE TWO END
LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE RIGHT TO
REJECT A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT WRITTEN
JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE
FIBER MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED
INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL
LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE
RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN
WITH THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING.
7. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
8. COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.
GOVERNMENT BYDISA GOC IP B/D312-770-8627,C001-618-220-86 WHO
WILL SUBMIT A COMPLETION REPORT IAW DISAC 310-130-1, CHAP 2 OF
DISAC 310-70-1, CHAP 8. REPORT WILL BE ADDRESSED TO THE
ORIGINATOR AND ALL ADDRESSEES OF THIS TSO.
9. TEST & ACCEPTANCE INSTRUCTIONS: ALL EQUIPMENT AND CIRCUIT
PROBLEMS WILL BE REPORTED BY PHONE TO DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C)
618-220-9950(D) 770-9950; TOLL FREE: 855-868-9950
10. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO
350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS
AVAILABLE AT. CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE
COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."