Attachment-Circuit_Parameters_for_Solicitation_QA905_4-30-18.docx
DOCX document 13 KB Posted
- Solicitation number
- HC101317QA905
- Issued by
-
Defense Information Systems Agency
About this file
Circuit parameters
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sample_Vendor_Block_Diagram_and_Circuit_Path_Maps_Version2.pdf | ||
| Attachment-Testing_Requirements_for_Solicitation_QA905_4-30-18.docx | DOCX document | |
| HC101317QA905-0005.v0__5-1-18.pdf | ||
| HC101317QA905.v1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIRCUIT PARAMETERS FOR SOLICITATION HC101317QA905
CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: STS-48C, 1310NM RATE: PLUS
OR MINUS 20 PPM USER PROVIDED STS-48C FRAMING FROM GOVT CISCO
SWITCH
(B) NO CHANNELIZATION REQUIRED.
(C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24
HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(D) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED.
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT.
(F) SINGLE MODE FIBER TERMINATIONS SC/SC CONNECTORS
(G) NO NETWORK INTERFACE UNIT.
(H) DEDICATED PATH.
(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
(J) VENDOR MUST TEST CIRCUIT END TO END FOR 24 HOURS UTILIZING A
2E23 TEST PATTERN.
(K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(L) COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE
GOVERNMENT BY DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION
GROUP, SCOTT AFB, IL. (C) 618-220-8627 (D) 770-8627
(M) VENDOR MUST PROVIDE:
1. LONG HAUL CIRCUIT NO. AND LEC CKT ID. PRIOR TO TURN UP TO THE GOVERNMENT.
2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF OC-48C SERVICE IAW UNIQUE INSTALLATION FACTORS.
3. INSIDE WIRING IS AUTHORIZED IAW UNIQUE INSTALLATION FACTORS.
4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN
ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER
LOCATIONS. IF UNABLE TO REACH SITE POC'S CONTACT KEN DIEF OR RAY
BURKE IMMEDIATELY FOR ASSISTANCE AT: (301) 225-2416/2550