The file's text, extracted by GovTribe without its formatting.
Attachment 7 – Facilities Listing H92240-14-Q-9021
Contractor-provided training site for CQC shall meet the following specifications for shooting ranges, tactical shoot houses and support facilities:
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.1.
Reactive fixed steel plate ranges
| 4.1.1.1 |
| 4 firing lanes with 8 reactive 8 inch steel head plates |
| 4.1.1.2 |
| 9 stationary steel targets each measuring one square foot |
| 4.1.1.3 |
| 3 stationary steel targets each measuring 2 feet by 3 feet |
| 4.1.1.4 |
| 8 portable steel silhouette targets |
| 4.1.1.5 |
| Shooting positions at distance from 3 to 25 yards |
| 4.1.1.6 |
| Shall simultaneously support 30 shooters |
| 4.1.1.7 |
| Shall support M4 SOPMOD (5.56mm) and Sig Sauer P226 pistol (9mm) |
| 4.1.1.8 |
| Shall support shooting and moving drills |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.2.
Competition (Person vs. Person) reactive steel ranges
| 4.1.2.1 |
| 10 ranges that shall be able to be used simultaneously |
| 4.1.2.2 |
| Shooting positions from 7 to 12 yards |
| 4.1.2.3 |
| Shall support shooting and moving drills |
| 4.1.2.4 |
| Shall support M4 SOPMOD (5.56mm) and Sig Sauer P226 pistol (9mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.3.
Lateral Moving Steel Range (Side to Side)
| 4.1.3.1 |
| Steel plate rifle and pistol mover with left to right and right to left movement |
| 4.1.3.2 |
| Shall support M4 SOPMOD (5.56mm) and Sig Sauer P226 pistol (9mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.4.
Reactive steel 5.56mm capable with automatic target reset capabilities (Pneumatic)
| 4.1.4.1 |
| Shall be able to support shooting at distances from 10 to 200 yards |
| 4.1.4.2 |
| Shall have a minimum of 60 steel reactive targets |
| 4.1.4.3 |
| Shall support M4 SOPMOD (5.56mm) and Sig Sauer P226 pistol (9mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.5.
Static Rifle, Pistol and Shotgun ranges
| 4.1.5.1 |
| Shall be able to support firing lines from 7-25 yards |
| 4.1.5.2 |
| Shall be able to support 50 firing positions |
| 4.1.5.3 |
| Shall be able to support various paper target systems |
| 4.1.5.5 |
| Small, medium, large dots |
| 4.1.5.7 |
| Shall be able to support barricade shooting positions |
| 4.1.5.8 |
| Shall support M4 SOPMOD (5.56mm), Sig Sauer P226 pistol (9mm) and M870 Shotgun |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.6.
Urban Mock-up (Street Scene Façade) Range
| 4.1.6.1 |
| Targets shall be engaged from cover at a distance of 60 yards |
| 4.1.6.2 |
| Firing positions shall represent various urban settings |
| 4.1.6.7 |
| Shall support movement from shooting position to shooting position through rooms, doorways, vehicles and other obstacles |
| 4.1.6.8 |
| Shall have reactive steel targets that have automatic reset capability |
| 4.1.6.9 |
| Shall support M4 SOPMOD (5.56mm), and Sig Sauer P226 pistol (9mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.7.
Computerized Reactionary Steel Range
| 4.1.7.1 |
| Shall have at a minimum 4 firing lanes with 5 targets minimum per firing station |
| 4.1.7.2 |
| Targets shall be programmable for exposure for at least 1-3 seconds and shall reset automatically if not shot |
| 4.1.7.3 |
| Shall support Sig Sauer P226 pistol (9mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.8.
Shotgun Range
| 4.1.8.1 |
| Shall have at a minimum 5 skeet and trap launchers for clay targets |
| 4.1.8.2 |
| Shall have remote control from the left side, and right side, and with the shooter |
| 4.1.8.3 |
| Shall support M870 shotgun ammunition |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.9.
Sniper Range
| 4.1.9.1 |
| Shall have a 300 yard sniper range |
| 4.1.9.2 |
| Shall have at a minimum 6 shooting positions |
| 4.1.9.3 |
| Shall support 7.62mm, .300 Winchester magnum, and 5.56mm ammunition |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.10.
Shooting Tower
| 4.1.10.1 |
| Shall have a 25 foot minimum shooting tower |
| 4.1.10.2 |
| Shall support target engagement at distances from 45 yards to 200 yards |
| 4.1.10.3 |
| Shall support M4 SOPMOD (5.56mm) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.11.
Tactical Shoot House
| 4.1.11.1 |
| Shall have 2 tactical shoot houses |
| 4.1.11.2 |
| Each tactical shoot house shall be 10,000 square feet at a minimum |
| 4.1.11.3 |
| Each tactical shoot house shall have “cat walks” that provide visual observation of the entire floor plan |
| 4.1.11.4 |
| Tactical shoot houses shall be located within 100 yards of each other |
| 4.1.11.5 |
| Each tactical shoot house shall be sited for a maximum credible event of 1 pound Net Explosive Weight (NEW) C/D 1.1 explosives |
| 4.1.11.6 |
| Each tactical shoot house shall have the capability of being used simultaneously |
| 4.1.11.7 |
| Each shoot house shall support the following scenarios: |
| 4.1.11.7.1 |
| Center fed room |
| 4.1.11.7.2 |
| Corner fed room |
| 4.1.11.7.4 |
| Narrow hallway |
| 4.1.11.7.9 |
| Multiple connecting rooms |
| 4.1.11.7.10 |
| Multiple entry locations |
| 4.1.11.7.11 |
| Multiple simultaneous entries |
| 4.1.11.8 |
| All tactical shoot houses shall be evaluated by a Naval Special Warfare Command evaluation assessment team and be deemed suitable for Naval Special Warfare training as set forth in COMNAVSPECWARCOMNOTE 3550, 04 April 2008 before the facility will be deemed suitable for use. |
| 4.1.11.9 |
| Tactical shoot houses shall have had an Air Sampling evaluation for lead contamination and been found below the exposure limits set by Navy Occupational Safety and Health. Contractor shall maintain acceptable air quality standards set by Navy Occupational Safety and Health for the duration of the contract. |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.12.
Student Classroom
| 4.1.12.1 |
| Shall have an indoor classroom that will support up to 75 students |
| 4.1.12.2 |
| Shall have power |
| 4.1.12.3 |
| Shall have visual aid panels (VAP) |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.13.
Student Housing
| 4.1.13.1 |
| Shall have the capacity to house 75 students |
| 4.1.13.2 |
| Housing shall be within 300 yards of Range training area |
| 4.1.13.3 |
| Housing shall have the ability to support up to 75 students |
| 4.1.13.6 |
| Washer and Dryer |
| 4.1.13.7 |
| Kitchen with cooking and eating utensils |
| 4.1.13.8 |
| Refrigeration for perishable food items for up to 75 students |
| 4.1.13.9 |
| Linen shall be provided for up to 75 students |
| 4.1.13.10 |
| Shall have at least one large screen TV with audio jacks, video jacks and DVD players to support training de-briefs |
| 4.1.13.11 |
| Student housing will be paid for by each individual service members using their Government Travel Credit Card and WILL NOT be included in the pricing for facility use. The Government will only pay for exact number of students. |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.14.
Armory
| 4.1.14.1 |
| Shall support the safe storage of: |
| 4.1.14.5 |
| 50 sniper weapons systems |
| 4.1.14.6 |
| All armories shall be secured with a monitored alarm system |
| 4.1.14.7 |
| Ammunition and Demolition Storage Magazines |
| 4.1.14.8 |
| Ammunition and Demolition Storage Magazines shall have been properly cited by the Department of Defense Explosives Safety Review Board |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.15.
Weapons Cleaning
| 4.1.15.1 |
| Shall provide a weapons cleaning area for 75 students |
| 4.1.15.2 |
| Cleaning area shall have compressed air, adequate lighting, and sufficient tables |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.16.
Drop Zone for Airborne Operations
| 4.1.16.1 |
| Shall have a Drop Zone (DZ) certified by the United States Air Force within the last 2 years and maintain currency of certification throughout the life of the contract. DZ shall support: |
| 4.1.16.1.1 |
| Military and civilian rotary wing aircraft for day and night takeoff and landing operations |
| 4.1.16.1.2 |
| Personnel on-load and off-load operations for day and night rotary wing aircraft operations |
| 4.1.16.1.3 |
| Military Free-fall for day and night operations |
| 4.1.16.2 |
| Drop Zone shall be AMC approved (listed on the AMC Zone Availability |
Report - ZAR). Drop zone elevation not to exceed 2,000 feet MSL. Airspace compatible with HALO drops from 13,000 MSL. Drop zone shall be at a minimum:
| 4.1.16.2.1 |
| Length 1600 meters for static line drops |
| 4.1.16.2.2 |
| Width 700 meters for static line drops |
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.17.
Range Facilities shall be within a 100 mile radius of a Department of Defense Installation with an armory.
| PWS Section |
| Sub-section |
| Description |
| Yes |
| No |
4.1.18.
Contractor facilities shall be sufficiently secure, such as perimeter fencing, to discourage if not to prevent trespassing by unauthorized personnel. No contracted personnel other than those required to perform the tasks stated herein shall be allowed in the training area without approval of Naval Special Warfare. No photographs or video will be allowed of Naval Special Warfare personnel or of training being conducted without prior approval by Naval Special Warfare.