This is a Construction Bid Addendum No. 1 issued by the Michigan Department of Technology, Management and Budget (DTMB), State Facilities Administration, Design & Construction Division for the Gus Harrison Correctional Facility Smoke Purge System Repair/Replace project (File Number 472/25081.GSA). The addendum, dated July 20, 2026, was issued by Matrix Consulting Engineers with Project Director David Lenz and Professional Troy Thelen. The addendum includes three primary items: the pre-bid meeting attendance sign-in sheet, re-issued electrical sheets E-506, E-600, and E-601 with clarifications regarding Base Bid, Alternate #1, and Alternate #2 work specifications, and a revised bid due date extended from July 29, 2026 to August 5, 2026. The addendum must be acknowledged by bidders in the bid summary and bid form, as failure to acknowledge may result in bid rejection.

The addendum provides detailed electrical specifications for Building 500 (Warehouse) work at the correctional facility, including the installation of new 250-ampere, 3-phase circuit breakers in the existing SSBPB switchboard for Housing Units 4 and 5, disconnection and reconnection of existing electrical conduit and wire, splicing of conductors in new NEMA 4 pullboxes, and installation of new underground conduits with 4-inch concrete encasement using hydrovac trenching methods. Additional responsibilities assigned to the contractor include performing an arc flash study, breaker settings calculations, fuse size determinations, trip settings, and preventative maintenance on all medium voltage switchgear and cables. The project involves coordination with existing electrical infrastructure including a 1000-kilowatt/1250-kilovolt-ampere emergency generator and temporary generator connection provisions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0414 (Rev 6/25)

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND

BUDGET

State Facilities Administration Design & Construction Division

CONSTRUCTION BID ADDENDUM NO. 1

This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.

TO:

ALL BIDDERS

DATE ISSUED 7/29/2026

PROJECT NAME

Gus Harrison Correctional Facility – Smoke Purge System Repair/ Replace

FILE NUMBER

472/25081.GSA

PROFESSIONAL

Matrix Consulting Engineers

PROJECT DIRECTOR

David Lenz

BID OPENING DATE:

7/29/2026

ADDENDUM ITEMS:

1. Attached is the pre-bid meeting attendance sign-in sheet.

2. Re-Issued Sheets E-506, E-600, and E-601 (Attached). Updated to include clarifications between

Base Bid, Alternate #1, and Alternate #2 work.

3. Revised bid due date from 7/29/26 to 8/5/26

ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.

PROFESSIONAL: Troy Thelen, Matrix DATE: 7/20/2026

APPROVED BY:

PROJECT DIRECTOR: David Lenz DATE: 7/20/2026

8/5/26

David Lenz Line

ELECTRICAL DEMOLITION NOTES

T 15 KVA

T 30 KVA

TS TS

EXIST PANEL "RP-J"

EXIST. 1600A SWITCHBOARD

"SSBPB"

EXIST 800A AUTO TRANS.

SWITCH "ATS-SEMPB"

EXIST 30 KVA TRANS

EXIST DIS. PANEL "DDP"

EXIST. PANEL "RP-X"

EXIST 15 KVA TRANS.

EXIST PANEL "LP-XX"

EXIST DIS. PANEL "MPB"

SECTION A

EXIST DIS. PANEL "MPB"

SECTION B

EXIST 1600A AUTO TRANS.

SWITCH "ATS-SSBPB"

EXIST DIS. PANEL "SEMPB"

EXIST 1600A ENCLOSED

CIRCUIT BREAKER

EXIST UNDERGROUND ELECTRICAL VAULT

EXIST TEMP GENERATOR

CONNECT CABINET

EXIST L5-15R RECEPT FOR

TEMP GEN. START SIGNAL

EXIST L14-30R RECEPT FOR

TEMP GEN. TRAILER

EXIST NEMA 4 JUNCTION BOX

EXIST BLDG 500 SUB #501

1. SEAL ALL PENETRATIONS WITH LIKE MATERIAL TO MAINTAIN ORIGINAL

RATING. FIRE CAULK ALL FIRE RATED WALLS TO MAINTAIN ORIGINAL FIRE

RATING.

GENERAL ELECTRICAL NOTES

ELECTRICAL KEY NOTES

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

INSTALL (1) NEW 250A/3P CIRCUIT BREAKER IN EXISTING PANEL 'SSBPB' FOR

HU4.

INSTALL (1) NEW 250A/3P CIRCUIT BREAKER IN EXISTING PANEL 'SSBPB' FOR

HU5.

NEW NEMA 4 JUNCTION BOX

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

DISCONNECT & PULL EXISTING CONDUIT & WIRE BACK TO EXISTING

ELECTRICAL VAULT FOR HU4. EXISTING WIRE TO BE RE-USED FOR FEED TO

NEW PULLBOX.

DISCONNECT & PULL EXISTING CONDUIT & WIRE BACK TO EXISTING

ELECTRICAL VAULT FOR HU5. EXISTING WIRE TO BE RE-USED FOR FEED TO

NEW PULLBOX.

ALTERNATE #1

ALTERNATE #2

21ALTERNATE #1

ALTERNATE #2

ALTERNATE #1

ALTERNATE #2

ALTERNATE #2

ALTERNATE #1 A1

A1

A1

A1

E-506

TRB

JFS

BLDG 500-WAREHOUSE-

ELECTRICAL PLAN

file no.

checked by drawn by consultant issue date contract order no.

consultant job no.

24239.00

M a t r ix

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

F A

C

IL

IT

IE

S A

N D

B U

S

IN

E S

S S

E R

V

IC

E S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

472/24055.DPL

funding code sheet description

HOUSING UNIT 4

KEY PLAN

HOUSING UNIT 5

SUPPORT

SERVICES

7/8/2026 CD SET

BUILDING

7/20/2026 ADDENDUM #1

N BLDG 500-WAREHOUSE-ELECTRICAL PLAN

SCALE: 1/8" = 1'-0"

0 1 5 10 20

G 800A 3P

1600A 3P

NEUTRAL BAR

GROUND BAR

BONDING JUMPER

REBAR IN CONCRETE

EQUIPMENT PAD

EXIST CONCRETE ENCASED ELECTRODE

UFER GROUND

#1/0 BARE CU

EXIST

#6 BARE CU

EXIST

3/4" X 10'-0" DRIVEN

GROUND RODS AT

EACH CORNER OF

EQUIPMENT PAD.

K K

KIRK-KEY INTERLOCK BETWEEN

BREAKER AND CAM-LOCK

CONNECTION ACCESS DOOR

CAM-LOCK CONNECTORS FOR MDOC

TEMP GENERATOR TRAILER FOR WHEN

EMERGENCY GENERATOR IS OFF LINE

FOR MAINTENANCE.

EXIST

TEMP GENERATOR CONNECTION CABINET

PER ASCO 300 DUAL PURPOSE QUICK

CONNECT PANEL W/ BREAKERS

800A, 480Y/277V, 3Ø, 4W

EXIST

ATS-SSBPB

1600A, 480Y/277V, 3Ø, 4W

4 POLE

EXIST BLDG 100 & 200

CONDUCTORS THROUGH

4" UNDERGROUND CNDS

TO BLDG 100 TO BLDG 200

EXIST JUNCTION BOX ON BLDG EXTERIOR

NEMA 4 ENCLOSURE

EXIST UNDERGROUND

ELECTRICAL

VAULT

800A 3P

30A 3P

60A 3P

60A 3P

100A 3P

60A 3P

150A 3P

70A 3P

400A 3P

20A 3P

15A 3P

60A 3P

800A 3P

1600A 3P

600A 3P

3000A 3P

800A 3P

EXIST MEDIUM VOLTAGE

SWITCHGEAR EXIST

NORTH CAMPUS SUBSTATION

1500/2000KVA AA/FA, 12470V:480Y277V

1600A 3P

EXIST

1600 ENCLOSED

CIRCUIT BREAKER

EXIST 1600A TAP

LENGTH OF TAP CONDUCTORS

MAY NOT EXCEED 25'

30A 3P

600A 3P

PANEL

DISTRIBUTION

"DPP"

100A 3P

PANEL

"RP-J"

NORMAL POWER

FEED TO BUILDING

500 ATS

WAS REMOVED

NO LONGER IN USE

1600A 3P

J

PANEL

BUILDING 500

"LP-XX"

PANEL

BUILDING 500

"RP-X"

30 KVA

TRANSFORMER

BUILDING 500

15 KVA

TRANSFORMER

SALLY PORT

GUARD TOWER

EXERCISE YARD

GUARD TOWER

HOUSING

UNIT 4

HOUSING

UNIT 5

BUILDING

PANEL

EMERGENCY

EMPB

BUILDING

PANEL

EMERGENCY

BUILDING 500

45 KVA

TRANSFORMER

LP/GAS VAPORIZER 9 KVA

TRANSFORMER

SPARE

30A 3P

30A 3P

40A 3P

40A 3P

40A 3P

50A 3P

BUILDING

PANEL

EMERGENCY

HOUSING

UNIT 2

PANEL

EMERGENCY

HOUSING

UNIT 1

PANEL

EMERGENCY

HOUSING

UNIT 3

PANEL

EMERGENCY

BUILDING

PANEL

EMERGENCY

HOUSING

UNIT 6

PANEL

EMERGENCY

EXIST BUILDING 500 PANEL "MPB"

600A, 480Y/277V. 3Ø. 4W

DISTRIBUTION PANEL "SEMPB" SECTION A

800A, 480Y/277V, 3Ø,4W

DISTRIBUTION PANEL "SEMPB" SECTION B

800A, 480Y/277V, 3Ø,4W

EXIST

ATS-SEMPB

800A, 480Y/277, 3Ø, 4W

4 POLE

EXIST

SWITCHBOARD "SSBPB"

1600A, 480Y/277V. 3Ø, 4W

EXIST EMERGENCY GENERATOR

1000KW/1250KVA, 480Y/277V, 3Ø. 4W

DISCONNECT & PULL EXISTING CONDUIT & WIRE BACK TO EXISTING

ELECTRICAL VAULT. EXISTING WIRE TO BE RE-USED FOR FEED TO NEW

PULLBOX.

EXISTING EQUIPMENT TO REMAIN.

EXISTING CONDUIT & WIRE TO REMAIN.

PANEL

EXISTING

'EMPB'

480/277V 3Ø, 4W

100A MCB

PANEL

EXISTING

'EMPB'

480/277 3Ø, 4W

60A MCB

RISER DIAGRAM

DEMOLITION NOTES

250A 3P

PANEL

EXISTING

MPB

HU4

250A 3P

PANEL

EXISTING

MPB

HU5

EXIST UNDERGROUND

ELECTRICAL

VAULT

1 1

EXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXIST

EXIST

EXIST

EXIST EXIST

EXIST EXIST EXIST

EXIST

EXIST

EXIST EXIST EXIST

EXISTEXIST

ALTERNATE #1ALTERNATE #2

A1

A1

A1 file no.

checked by drawn by consultant issue date contract order no.

consultant job no.

24239.00

M a t r ix

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

F A

C

IL

IT

IE

S A

N D

B U

S

IN

E S

S S

E R

V

IC

E S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

472/24055.DPL

funding code sheet description

7/8/2026 CD SET

7/20/2026 ADDENDUM #1

BUILDING 500 RISER-DEMO

SCALE: NTS

EXISTING ELECTRICAL

RISER DIAGRAM

1. CONTRACTOR IS RESPONSIBLE FOR ARC FLASH STUDY, BREAKER SETTINGS, FUSE

SIZES, AND TRIP SETTINGS.

2. PREVENTATIVE MAINTENANCE IS TO BE PERFORMED ON ALL MEDIUM VOLTAGE

SWITCHGEAR AND CABLES.

GENERAL ELECTRICAL NOTES

ELECTRICAL KEY NOTES

INSTALL NEW 250A/3P CIRCUIT BREAKER IN EXISTING PANEL 'SSBPB'.

RUN EXISTING (6) #250 KCMIL, (1) #1/0 GND. IN NEW 4" CND TO NEW NEMA 4

PULLBOX.

SPLICE EXISTING (6) #250 KCMIL, (1) #1/0 GND. TO NEW (6) #250 KCMIL, (1)

#1/0 GND.IN NEW 4" CND IN NEW NEMA 4 PULLBOX.

HU4 HU5

EXISTING HU4 CONDUCTORS

THROUGH NEW 4"

UNDERGROUND CNDS WITH 4"

CONCRETE ENCASEMENT TO

EXISTING UNDERGROUND

ELECTRICAL VAULT. ALL

TRENCHING SHALL BE

PERFORMED USING HYDROVAC.

NEW JUNCTION BOX ON BLDG EXTERIOR

NEMA 4 ENCLOSURE

NEW

250A 3P

NEW

250A 3P

NEW

(6) #250 KCMIL,

(1) #1/0 GND.,

(1) 4" CND.3

G 800A 3P

1600A 3P

NEUTRAL BAR

GROUND BAR

BONDING JUMPER

REBAR IN CONCRETE

EQUIPMENT PAD

EXIST CONCRETE ENCASED ELECTRODE

UFER GROUND

#1/0 BARE CU

EXIST

#6 BARE CU

EXIST

3/4" X 10'-0" DRIVEN

GROUND RODS AT

EACH CORNER OF

EQUIPMENT PAD.

K K

KIRK-KEY INTERLOCK BETWEEN

BREAKER AND CAM-LOCK

CONNECTION ACCESS DOOR

CAM-LOCK CONNECTORS FOR MDOC

TEMP GENERATOR TRAILER FOR WHEN

EMERGENCY GENERATOR IS OFF LINE

FOR MAINTENANCE.

EXIST

TEMP GENERATOR CONNECTION CABINET

PER ASCO 300 DUAL PURPOSE QUICK

CONNECT PANEL W/ BREAKERS

800A, 480Y/277V, 3Ø, 4W

EXIST

ATS-SSBPB

1600A, 480Y/277V, 3Ø, 4W

4 POLE

EXIST BLDG 100 & 200

CONDUCTORS THROUGH

4" UNDERGROUND CNDS

TO BLDG 100 TO BLDG 200

EXIST JUNCTION BOX ON BLDG EXTERIOR

NEMA 4 ENCLOSURE

EXIST UNDERGROUND

ELECTRICAL

VAULT

800A 3P

30A 3P

60A 3P

60A 3P

100A 3P

60A 3P

150A 3P

70A 3P

400A 3P

20A 3P

15A 3P

60A 3P

800A 3P

1600A 3P

600A 3P

3000A 3P

800A 3P

EXIST MEDIUM VOLTAGE

SWITCHGEAR EXIST

NORTH CAMPUS SUBSTATION

1500/2000KVA AA/FA, 12470V:480Y277V

1600A 3P

EXIST

1600 ENCLOSED

CIRCUIT BREAKER

EXIST 1600A TAP

LENGTH OF TAP CONDUCTORS

MAY NOT EXCEED 25'

30A 3P

600A 3P

PANEL

DISTRIBUTION

"DPP"

100A 3P

PANEL

"RP-J"

NORMAL POWER

FEED TO BUILDING

500 ATS

WAS REMOVED

NO LONGER IN USE

1600A 3P

J

PANEL

BUILDING 500

"LP-XX"

PANEL

BUILDING 500

"RP-X"

30 KVA

TRANSFORMER

BUILDING 500

15 KVA

TRANSFORMER

SALLY PORT

GUARD TOWER

EXERCISE YARD

GUARD TOWER

HOUSING

UNIT 4

HOUSING

UNIT 5

BUILDING

PANEL

EMERGENCY

EMPB

BUILDING

PANEL

EMERGENCY

BUILDING 500

45 KVA

TRANSFORMER

LP/GAS VAPORIZER 9 KVA

TRANSFORMER

SPARE

30A 3P

30A 3P

40A 3P

40A 3P

40A 3P

50A 3P

BUILDING

PANEL

EMERGENCY

HOUSING

UNIT 2

PANEL

EMERGENCY

HOUSING

UNIT 1

PANEL

EMERGENCY

HOUSING

UNIT 3

PANEL

EMERGENCY

BUILDING

PANEL

EMERGENCY

HOUSING

UNIT 6

PANEL

EMERGENCY

EXIST BUILDING 500 PANEL "MPB"

600A, 480Y/277V. 3Ø. 4W

DISTRIBUTION PANEL "SEMPB" SECTION A

800A, 480Y/277V, 3Ø,4W

DISTRIBUTION PANEL "SEMPB" SECTION B

800A, 480Y/277V, 3Ø,4W

EXIST

ATS-SEMPB

800A, 480Y/277, 3Ø, 4W

4 POLE

EXIST

SWITCHBOARD "SSBPB"

1600A, 480Y/277V. 3Ø, 4W

EXIST EMERGENCY GENERATOR

1000KW/1250KVA, 480Y/277V, 3Ø. 4W

PANEL

EXISTING

'EMPB'

480/277V 3Ø, 4W

100A MCB

PANEL

EXISTING

'EMPB'

480/277 3Ø, 4W

60A MCB

250A 3P

PANEL

EXISTING

MPB

250A 3P

PANEL

EXISTING

MPB

EXIST UNDERGROUND

ELECTRICAL

VAULT

EXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXISTEXIST

EXIST

EXISTEXIST

EXIST

EXIST

EXIST

EXIST

EXIST

EXIST EXIST

EXIST EXIST EXIST

EXIST

EXIST

EXIST EXIST EXIST

EXISTEXIST

NO LONGER IN USE

EXISTING HU5 CONDUCTORS THROUGH NEW 4"

UNDERGROUND CNDS WITH 4" CONCRETE

ENCASEMENT TO EXISTING UNDERGROUND

ELECTRICAL VAULT. ALL TRENCHING SHALL BE

PERFORMED USING HYDROVAC.

NEW

(6) #250 KCMIL,

(1) #1/0 GND.,

(1) 4" CND. 3

ALTERNATE #1ALTERNATE #2

A1

A1

A1

REVISED ELECTRICAL

RISER DIAGRAM

file no.

checked by drawn by consultant issue date contract order no.

consultant job no.

24239.00

M a t r ix

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

F A

C

IL

IT

IE

S A

N D

B U

S

IN

E S

S S

E R

V

IC

E S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

472/24055.DPL

funding code sheet description

7/8/2026 CD SET

7/20/2026 ADDENDUM #1

BUILDING 500 RISER-NEW

SCALE: NTS

DTMB-0414 (Construction Addendum)
Sign In Sheet
E506-2423900-24x36
E600-2423900-30x42
E601-2423900-30x42

File details come from the government source that posted it. Updated .