GS-07P-14-HH-D-0006.pdf

PDF 612 KB Posted

Attached to
IDIQ General Construction, Repair & Alteration Services for the Houston Zone
Solicitation number
GS-07P-14-HH-D-0006
Issued by

About this file

Solicitation GS-07P-14-HH-D-0006

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA Solicitation No. GS-07P-14-HH-D-0006

THE GENERAL SERVICES ADMINISTRATION (GSA) IS SETTING ASIDE THIS CONTRACT UNDER THE FOLLOWING CLAUSE

FOUND IN THE AGREEMENT: FAR 52.219-6

General Services Administration Public Buildings Service

Region 7

Solici tation GS-07P-14-HH-D-0006 IDIQ Construction for Federally-Owned & Leased

Federal Facil i t ies in the Houston Zone

SOLICITATION NUMBER: GS-07P-14-HH-D-0006

SERVICE: Multiple Award, Indefinite Delivery/Indefinite

Quantity (IDIQ) Contract for Construction, Repair &

Alteration Services for GSA-Owned and –Leased

Facilities in the Houston Zone

LOCATION(S): Multiple

PERIOD OF PERFORMANCE: One (1) Base and Four (4) One-Year Options

SOLICITATION ISSUE DATE: April 24, 2014

PRE-PROPOSAL MEETING: May 8, 2014, 8:30 AM, CST Pre-Proposal Conference at:

GT Leland Federal Building 1919 Smith Street, Room 16100 Houston, TX 77002

OR at the Lanham Federal Building, 819 Taylor St., Room 12A01, Fort Worth, TX 76102

OR via teleconference: Call in number 1866-564-9718 Participant pass code 1817722

PRE-REGISTRATION REQUIRED

QUESTIONS: The final submission date for questions is May 15, 2014. Questions must be sent via email to Carolina McGillick at Carolina.mcgillick@gsa.gov

OFFER RECEIPT DATE/TIME: June 4, 2014, 2:00 PM, Central Standard Time

THIS PROCUREMENT IS 100% TOTAL SMALL BUSINESS SET-ASIDE

THE GENERAL SERVICES ADMINISTRATION (GSA) IS SETTING ASIDE THIS CONTRACT UNDER THE

FOLLOWING CLAUSE FOUND IN THE AGREEMENT: FAR 52.219-6 (“NOTICE OF TOTAL SMALL BUSINESS SET ASIDE”).

PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR

DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO

UNAUTHORIZED USERS IS PROHIBITED

Do not remove this notice

Properly destroy documents when no longer needed

ATTENTION OFFERORS

SPECIAL INSTRUCTIONS FOR LINE ITEM PRICING

SUBMITTAL

Use the attached spreadsheet titled: “GSA REGION 7

CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

HOUSTON ZONE” for submitting your line item prices. Please include your spreadsheet in Excel format in the USB Flash Drive containing proposal.

NOTE: BOTH THE TECHNICAL PROPOSAL AND THE PRICING

PROPOSAL MUST BE SUBMITTED IN ELECTRONIC FORMAT.

THE TECHNICAL PROPOSAL MUST BE IN A PDF FORMAT FILE

CLEARLY LABELED. THE PRICING PROPOSAL MUST BE IN A

PDF FORMAT FILE CLEARLY LABELED, AND THE PRICING OF

LINE ITEMS MUST BE IN EXCEL FORMAT USING ATTACHED

SPREADSHEET. FILES MUST BE SAVED ONTO AN USB FLASH

DRIVE AND MAILED TO THE ADDRESS LISTED ON THE

SOLICITATION. NO PAPER COPIES ARE REQUIRED.

Line Item

Number

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

1.00 DIV 1 - GENERAL CONDITIONS

1.01 Project Manager MH

1.02 Laborer MH

1.03 Carpenter MH

1.04 Painter MH

1.05 Paper Hanger MH

1.06 Plaster MH

1.07 Ceramic tile installer MH

1.08 Carpet Installer MH

1.09 Plumber/Pipe Fitter MH

1.10 A/C Mechanic MH

1.11 Electrician MH

2.00 DIV 2 - EXISTING CONDITIONS - DEMOLITION

2.01 Demo partition, complete, metal or wood stud and gypsum, or demountable partitions, includes one electrical or mechanical device and 10' conduit per 100 SF

SF

2.02 Demo partition, add to partition demo, expanded metal fastened to metal studs SF

2.03 Demo partition, Terracotta/Brick/Block, 4-12" thick, with or without plaster finish CF

2.04 Demo plaster, on wall or ceiling, includes wood or metal lath SF

2.05 Demo wall covering, vinyl or fabric, including cleaning of the wall surface SF

2.10 Demo door and frame, from drywall or demountable partition, single, includes hardware removal EA

2.11 Demo door, wood or metal, single EA

2.12 Demo frame, wood or metal, single or double EA

2.13 Demo door, add for hardware removal and storage, includes lockset, closures, hinges EA

2.14 Demo window, frame and glazing, to 25 SF EA

2.20 Demo flooring, carpet, bonded, releasable adhesive, broadloom or tile, includes surface scraping SF

2.21 Demo flooring, carpet, bonded, permanent adhesive, broadloom or tile, includes surface scraping SF

2.22 Demo flooring, carpet, tacked down, includes pad and tack strip per SOW SF

2.23 Demo flooring, add for double stick removal, includes surface scraping SF

2.24 Demo flooring, VCT, includes surface scraping and cleaning SF

2.25 Demo flooring, and re-install access floor panels for work below, standard 2' x 2' EA

2.26 Demo wall base, vinyl, rubber, or wood. LF

2.27 Demo door stop, floor or wall mounted EA

2.30 Demo casework, remove cabinets, complete, wall or base, includes doors, drawers, top LF

2.31 Demo countertops, any material LF

2.40 Demo ceiling, mineral fiber tiles, on suspension system SF

2.41 Demo ceiling, suspension system, includes hangers SF

2.50 Demo chair rail, any material LF

2.51 Demo or dismantling of bookcases, price shall be determined by the square feet face or front view of bookcase.

SF

3.00 DIV 3 - CONCRETE

3.01 Concrete core drilling, add per inch of depth over 6" slab EA

3.02 Concrete core drilling, core, reinforced concrete slab, 1" diameter, up to 6" thick slab, includes bit, layout and set up

EA

3.03 Concrete core drilling, core, reinforced concrete slab, up to 6" diameter, up to 6" thick slab, includes bit, layout and set up

EA

3.04 Repair sub-floor, masonry, where damaged from wall or object removal up to 1/4" thick SF

6.00 DIV 6 - WOOD, PLASTICS, AND COMPOSITES

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

6.20 Moldings, base, oak equivalent, nominal 3/4" x 3" LF

6.21 Moldings, base, oak equivalent, nominal 3/4" x 6" LF

6.22 Moldings, base, shoe, oak equivalent, 1/2" x 3/4" LF

6.23 Moldings, trim, chair rail, oak equivalent, 5/8" x 2-1/2" LF

6.24 Moldings, trim, crown, stock oak, 4-5/8" LF

6.25 Moldings, casings, stock profiles, oak equivalent, 3/4" x 2-3/4" LF

7.00 DIV 7 - THERMAL AND MOISTURE PROTECTION

7.01 Insulation, recycled blue cotton fiber, unfaced batts, R13 in walls SF

7.02 Insulation, sound attenuation blanket 3" thick, mineral wool fiber for ceiling SF

7.03 Insulation, sound attenuation blanket, 3-1/2" thick, fiberglass for ceiling SF

7.04 Insulation, sound attenuation system, mineral fiberboard panel, fabric covered, concealed spline, wall mounted

SF

8.00 DIV 8 - OPENINGS

8.01

Door assembly, wood doors and hollow metal frames, solid particle core, nominal 3'-0" x 7'-0" x 1-

3/4",oak equivalent factory finished, 16 gauge hollow metal frame, prime and two coats paint on frame. Includes hinges, door stop, door silencers, excludes lockset

EA

8.02 Door, wood, flush, solid particle core, 1-3/4" thick, nominal 3' x 7', oak equivalent, excludes lockset EA

8.03 Door, wood fire door, "B" label 1 hour, solid particle core, flush, 1-3/4" thick, nominal 3' x 7', oak equivalent, excludes lockset

EA

8.04 Door, wood fire door, "B" label 90 minute, solid wood core, flush, 1-3/4" thick, nominal 3' x 7', oak equivalent, excludes lockset

EA

8.05 Door, hollow metal core, 20 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset EA

8.06 Door, metal fire door, "B" label 90 minute, 20 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset EA

8.07 Door, metal fire door, "A" 3 hour, egress core, 18 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset

EA

8.08

Door, add for vision lite, into any door with safety glass tempered or fire rated wired, lite tinted or clear glass and wood or metal frame. Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame.

EA

8.14 Door frame, standard hollow metal 16 gauge, single nominal 3' x 7', upto 5-3/4" jamb depth EA

8.15 Door frame, standard hollow metal 16 gauge, double nominal 6' x 7', upto 5-3/4" jamb depth EA

8.16 Door frame, add for welded frame EA

8.30 Access panel, latch-locking metal access panel, up to 22" x 22" in size EA

8.31 Louver in any door, wood or metal frame (24" x 24" max). Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame.

SF

8.40 Door frame, aluminum, single door, clear or bronze per SOW 3'x7' EA

8.41 Door frame, aluminum, double door, 6 ft wide, clear or bronze per SOW EA

8.42 Door, aluminum entrance, narrow stile clear or bronze per SOW, includes hinges, push/pull, deadlock, cylinder, threshold, and 1/4" tempered glazing 3'x7'

EA

8.50 Window, in partition, safety glass, not to exceed 36 SF per unit, 16 gauge hollow metal frame, 3/8" glazing, cutting opening into standard partition, prime and two coats paint on frame.

SF

8.70 Door hardware, lockset, commercial, mortise, keyed, single cylinder EA

8.71 Door hardware, lockset, standard duty, cylindrical lockset, non-keyed EA

8.72 Door hardware, lockset, keyless pushbutton, Trilogy T2 style or approved equal EA

8.73 Door hardware, lockset, deadbolt, cylindrical or double cylindrical EA

8.74 Door hardware, add for electronic door release, includes transformer, electric strike, and push button EA

8.75 Door hardware, panic device, for rim device, outside key and pull EA

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

8.76 Door hardware, panic device, bar and vertical rod, outside key and pull EA

8.77 Door hardware, door closer onto any door, LCN model #4041 style or approved equal. EA

8.78 Door hardware, door closer with hold open, Norton model #1605 style or approved equal. EA

8.79 Door hardware, door stop or bumper, floor or wall mounted. EA

8.80 Door hardware, lockset, commercial, mortise, re-core cylinder EA

8.81 Door hardware, hinges, full mortise, average frequency, steel base, US26D or US10A, 4-1/2" x 4-

1/2"

PR

8.90 Trim door bottom, metal or wood door, up to 40" wide. Includes remove and reinstall. EA

9.00 DIV 9 - FINISHES

9.20 Partition, 3-5/8" 25 ga metal stud, 16" O.C., 5/8" type X gypsum on both sides, including tape and finish (level 4), primer and two finish coats paint

SF

9.21 Partition, add for additional lay of 5/8" gypsum wall board, no finish SF

9.22 Partition, storefront system, aluminum frame, commercial grade, 3/8" clear plate glass, 3' x 7' door with standard hardware

SF

9.23 Partition, 7/8" metal furring channel or 1-5/8" metal stud, 24" o.c., 5/8" gypsum one side, including tape and finish (level 4), primer, two finish coats of paint, and install 4" base.

SF

9.24 Partition, add for texture SF

9.25 Partition, add for 3/4" thick fire retardant plywood required for equipment - no finish SF

9.26 Partition, add for 9 gauge expanded metal, mechanically fastened, includes cutouts. SF

9.27 Partition, skim coat on existing wall or ceiling surface (drywall, CMU, etc.). SF

9.50 Ceiling, suspended ceiling tile, in existing suspended grid system, 5/8" lay-in mineral fiber SF

9.51 Ceiling, suspended ceiling tile, in existing suspended grid system, 3/4" lay-in mineral fiber SF

9.52 Ceiling, add for tegular tiles EA

9.53 Ceiling, class A suspension systems, 15/16" T bar, standard grid sizes SF

9.54 Ceiling, class A suspension systems, add for 9/16" grid SF

9.55 Ceiling, gypsum, 3-5/8" 20 ga metal stud, 16" O.C., 5/8" type X gypsum, including tape and finish

(level 4), primer and two finish coats paint

SF

9.60 Flooring, carpet tile, cushion back, tufted, to 20 oz. SY

9.61 Flooring, carpet tile, cushion back, tufted, to 26 oz. SY

9.62 Flooring, carpet tile, hard back, tufted, 26 oz. SY

9.63 Flooring, sheet carpet, medium traffic, plush, 30 oz. SY

9.64 Flooring, sheet carpet, medium traffic, plush, 36 oz. SY

9.65 Flooring, sheet carpet, medium traffic, plush, 42 oz. SY

9.66 Flooring, carpet, add for commercial grade pad, sponge rubber, felt, or bonded urethane. SY

9.67 Flooring, carpet, add for carpet binder bar beveled vinyl or beveled metal per LF

9.68 Flooring, patch carpet from partition removal (up to 6" wide). Government furnish carpet LF

9.69 Flooring, floor leveling, feathered to 1/2" thick, polymer-modified blend SF

9.70 Flooring, add for moving furniture and equipment, standard office furniture, not systems furniture SY

9.71 Flooring, add to raise and lower system furniture for removal and the installation of carpet. Cost is based per square yard covered by system furniture partition.

SY

9.75 Wall coverings, vinyl fabric backed, lightweight type 1, 12-15 oz per SY, including wall preparation, sizing, primer, sanding, etc.

SF

9.76 Wall coverings, vinyl fabric backed, mediumweight type 2, 20-24 oz per SY, including wall preparation, sizing, primer, sanding, etc.

SF

9.77 Wall coverings, vinyl fabric backed, heavyweight type 2, 28 oz per SY, including wall preparation, sizing, primer, sanding, etc.

SF

9.80 Base, cove or straight, rubber, 1/8" thick, 4" high, rubber, standard colors LF

9.81 Base, cove or straight, rubber, 1/8" thick, 6" high, rubber, standard colors LF

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

9.82 Flooring, resilient, vinyl composition tile, 1/8" thick, solid, 12" x 12" tile, conductive, includes glue SF

9.83 Flooring, resilient, rubber tile, 1/8" thick SF

9.84 Flooring, resilient, vinyl composition tile, 1/8" thick, solid, tile or plank, includes glue SF

9.90 Paint, walls complete, Includes surface preparation, primer, and two finish coats with roller SF

9.91 Paint, existing walls and ceilings, concrete, drywall or plaster, latex, primer, or seal coat, one coat with roller

SF

9.92 Paint, existing walls and ceilings, concrete, drywall or plaster, latex, two coats with roller SF

9.94 Paint, door and frame complete, paint jamb 2 coats enamel, paint door 2 coats latex, or polyurethane finish 2 coats. Finish per SOW

EA

9.95 Paint, door or frame, 3 ft x 7 ft nominal size, 1 side, 2 coats EA

9.96 Paint, door or frame, 3 ft x 7 ft nominal size, 2 sides, 2coats EA

9.97 Paint, base, wood, vinyl or metal. Up to 6" high, enamel, primer and 1 coat. LF

9.99 Paint, handrails (per rail), wood or metal, brushwork, Including wire brushing and/or sanding. LF

12.00 DIV 12 FURNISHINGS

12.30 Casework, manufactured, non-custom base cabinets, maximum, hardwood, pre-finished, door and drawers ordered per manufacturer options, min quantity two

LF

12.31 Casework, manufactured, non-custom wall cabinets, maximum, hardwood, pre-finished, door and drawers ordered per manufacturer options, min quantity two

LF

12.32 Casework, manufacturered, non-custom base cabinets, minimum, stock, plastic laminate door and drawers ordered per manufacturer options, min quantity two

LF

12.33 Casework, manufacturered, non-custom wall cabinets, minimum, stock, plastic laminate door and drawers ordered per manufacturer options, min quantity two

LF

12.34 Casework, counter-top, 25" deep with back and side splash, plastic laminate LF

12.35 Casework, counter-top, 25" deep with back and side splash, natural stone or quartz color group C LF

12.36 Casework, counter-top, 25" deep with back and side splash, solid surface LF

12.37 Casework, counter-top, add for cutout EA

21.00 DIV 21- FIRE SUPPRESSION (DIV 15)

21.01 Demo sprinkler head and all associated piping to the branch line and cap. Coordinate system shut-down with GSA and building maintenance.

EA

21.02 Demo sprinkler piping, up to 2" including all hangers, connectors, couplings, insulation. LF

21.03 Relocate existing sprinkler head, include up to 10 LF of new pipe, including all necessary piping required for relocation. Includes replacement of ceiling tile if necessary.

EA

21.10 Install new sprinkler head, concealed or standard spray , including fittings and escutcheons and up to

10 LF of new pipe.

EA

21.11 Drain and fill sprinkler system EA

21.20 Detection systems, horn and strobe EA

22.00 DIV 22 - PLUMBING (DIV 15)

22.01 Demo fixture, sink, including 10' piping EA

22.02 Demo fixture, urinal, wall mounted, including 10' piping EA

22.03 Demo fixture, water closet, wall or floor mounted, including 10' piping EA

22.04 Demo fixture, add for carrier supports removal EA

22.05 Demo piping, metal, up thru 1-1/2" diameter LF

22.06 Demo piping, metal, 2" - 3-1/2" diameter LF

22.07 Demo piping, metal, 4" - 6" diameter LF

22.08 Demo tank, water heaters, and liquid containers, to 45 gallon EA

22.09 Demo valves, metal valves, strainers and similar, up to 1-1/2" EA

22.10 Demo valves, metal valves, strainers and similar, 2" - 3" EA

22.15 Cleanouts, floor or wall type, 3" - 4" EA

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

22.16 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1/2" LF

22.17 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1" LF

22.18 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1-1/2" LF

22.19 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 2" LF

22.20 Piping, cast iron, waste line up to 4"; including all necessary hangers, supports, anchors, fittings, etc. LF

22.21 Piping, steel, schedule 40 or 80, includes couplings, hangers, and one fitting per 20', 2" LF

22.22 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1/2" EA

22.23 Piping, steel, schedule 40 or 80, includes couplings, hangers, and one fitting per 20', 3" LF

22.24 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1/2" - 1" EA

22.25 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1" - 2" EA

22.26 Pipe, insulation, 1/2" wall, closed cell foam rubber, up to 1" LF

22.27 Pipe, insulation, 1" wall, fiberglass with all service jacket, or foam, 1-1/2" - 2" LF

22.30 Electric water heater, instantaneous, 2.5 gal single element EA

22.41 Fixtures, urinal, wall hung, vitreous china, with hanger, 0.5 GPF EA

22.42 Fixtures, water closet, wall hung, vitreous china, 1.6 GPF unless otherwise specified EA

22.43 Fixtures, water closet, add for wall mounted rough in for carrier if req per fixture EA

22.44 Fixtures, water closet, floor mounted, vitreous china, 1.28 GPF unless otherwise specified, ADA EA

22.45 Fixtures, water closet, add for floor mounted rough in for supply, waste, vent, per fixture EA

22.46 Fixtures, sink, lavatory, wall mounted, vitreous china, no faucet EA

22.47 Fixtures, sink, kitchen style, stainless steel, single bowl EA

22.48 Fixtures, sink, kitchen style, stainless steel, double bowl EA

22.49 Fixtures, sink, bathroom style, stainless steel or porcelain enamel, single bowl EA

22.50 Fixtures, sink, add for sink rough in for supply, waste, vent, carrier if req, per fixture EA

22.51 Fixtures, faucet, bath, diverter spout combination EA

22.52 Fixtures, faucet, kitchen, single control lever with pull out spray EA

23.00 DIV 23 - HEATING VENTILATION AIR CONDITIONING (DIV 15)

23.01 Demo HVAC diffuser, registers, or grills, up to 24" EA

23.02 Demo flexible duct, prefabricated LF

23.03 Relocate existing thermostat electric or pneumatic, including all necessary wiring and piping. EA

23.04 Relocate existing diffuser, register, or grill, existing flexible duct EA

23.30 Diffuser, ceiling, T bar mounting, 24" x 24" lay-in frame, 8" - 12" diameter neck, spin-in collar, nylon ties, and connection into existing air supply duct.

EA

23.31 Diffuser, add for opposed blade damper or butterfly damper per SOW EA

23.32 Grill, ceiling, T bar mounting, 24" x 24" lay-in frame, plenum air return grille, eggcrate 1/2" x 1/2" x

1/2"

EA

23.41 Flexible duct, insulated 1" thick, 8" diameter LF

23.42 Flexible duct, insulated 1" thick, 10" diameter LF

23.42 Flexible duct, add for duct extension, existing damper and diffuser, collar adapter, up to 10' EA

26.00 DIV 26 ELECTRICAL (DIV 16)

26.01 Electrical demolition, remove electrical wall device, complete, switch, duplex, quadraplex, 120v, provide cover when needed, demo to nearest junction box

EA

26.02 Electrical demolition, electrical floor receptacle, tombstone, flush, or pedestal and provide cap and plug assemble. Provide cover when needed, demo to nearest junction box.

EA

26.03 Electrical demolition, conduit, EMT, to 15' high, 1/2" to 1", includes fitting and hangers LF

26.04 Electrical demolition, wire removed from in place conduit, to 15' high, #12 CLF

26.05 Electrical demolition, wire removed from in place conduit, to 15' high, #10 CLF

26.06 Electrical demolition, junction boxes 4" x 8" EA

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

26.07 Electrical demolition, device boxes to 4" square or octagon EA

26.08 Electrical demolition, interior fluorescent fixtures 4' long, including supports & whips, to 15' high EA

26.09 Electrical demolition, exit light EA

26.10 Electrical demolition, lamps, fluorescent EA

26.11 Electrical demolition, power pole any type and replace ceiling tile, demo to nearest junction box EA

26.12 Electrical demolition, emergency battery pack light unit EA

26.13 Electrical demolition, telephone, data, comm outlet and provide cover when needed EA

26.15 Electrical demolition, armored cable, #12, 3 wire LF

26.16 Electrical demolition, wire mold, 500, 700, 1500, 3000 or 4000, conduit up to 1-1/2", including conductors fittings and hangers, demo to nearest junction box.

LF

26.20 Conductors, branch line assembly, 3/4" EMT, #10 3 wire solid, includes couplings and hangers LF

26.21 Conductors, single wire, THWN or THHN, solid, #12 CLF

26.22 Conductors, single wire, THWN or THHN, solid, #10 CLF

26.23 Armored MC Cable, #12, 3 conductor, solid CLF

26.24 Armored MC Cable, #12, 4 conductor, solid CLF

26.25 Armored MC Cable, #10, 3 conductor, solid CLF

26.26 Armored MC Cable, #10, 4 conductor, solid CLF

26.27 Unshielded twisted pair (UTP) cable, solid, PVC jacket, #24 4 pair, Cat 5e unless otherwise specified CLF

26.28 Unshielded twisted pair (UTP) cable, solid, plenum, #24 4 pair, Cat 5e unless otherwise specified CLF

26.30 Conduit, EMT, 1/2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF

26.31 Conduit, EMT, 3/4", no wire, to 15' high with hangers, incl hanger, couplings, bends LF

26.32 Conduit, EMT, 1", no wire, to 15' high with hangers, incl hanger, couplings, bends LF

26.33 Conduit, EMT, 1-1/2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF

26.34 Conduit, EMT, 2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF

26.35 Conduit, sealtite, 3/4" LF

26.36 Device box, 4" square EA

26.37 Device plaster ring, 4" square EA

26.40 Receptacle, complete assembly, includes 1/2" conduit (10'), 4" square device boxes (2), plaster ring

4" square, #12 wire (3), receptacle duplex 120V grounded, 15A

EA

26.41 Receptacle, complete assembly in existing wall, includes MC Cable #12 (3) wire (15'), 2" square device box, plaster ring 2" square, receptacle duplex 120V grounded, 15A

EA

26.42 Receptacle, duplex, 120V, grounded, 15A EA

26.43 Receptacle, duplex, 120V, grounded, 20A EA

26.44 Receptacle, duplex, 120V, grounded, ground fault interrupting (GFI) 20A EA

26.45 Receptacle, duplex, 120V, isolated ground, 20A EA

26.46 Receptacle, duplex, 125V or 250V, corrosion resistant, NEMA L5 or L6 twistloc EA

26.47 Unshielded twisted pair (UTP) jack, RJ-45, #24, 4 pair, up to Category 6 EA

26.50 Switch, quiet type, single pole, 20A EA

26.51 Switch, quiet type, 3-way, 20A EA

26.52 Switch, single pole, dimmer, fluorescent up to 1000w, 20A EA

26.53 Switch, single pole, lock handle, 20A EA

26.54 Wall plates, stainless, metal, or wood, 1 gang EA

26.55 Wall plates, stainless, metal, or wood, 2 gang EA

26.56 Wall plates, stainless, metal, or wood, 3 gang EA

26.57 Wall plates, stainless, metal, or wood, 4 gang EA

26.58 Wall plates, plastic, 1 gang EA

Div.Sec

DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4

GSA REGION 7 CONSTRUCTION LINE ITEMS 2013 (PRICING FORM)

26.59 Wall plates, plastic, 2 gang EA

26.60 Wall plates, plastic, 3 gang EA

26.61 Wall plates, plastic, 4 gang EA

26.70 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 1' x 4' two 32w T8 unless specified

EA

26.71 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 2' two U 32w T8 unless specified

EA

26.72 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' two 32w T8 unless specified

EA

26.73 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' three 32w T8 unless specified

EA

26.74 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' four 32w T8 unless specified

EA

26.75 Lighting fixtures, add for air handling troffer EA

26.76 Lighting fixtures, add for parabolic lens in new fixture EA

26.77 Lighting fixtures, add for dimmable electronic ballast, up to 40w fluorescent, to 15' high EA

26.78 Lighting fixtures, down light , fluorescent, with lamps and acrylic lens, 4 pin tubes EA

26.79 Lighting fixtures, down light , add for wall wash trim EA

26.80 Lighting fixtures, replace acrylic lens with parabolic lens in existing fixture EA

26.81 Lighting fixtures, electronic ballast replacement, up to 40w fluorescent, to 15' high EA

26.82 Lighting fixtures, electronic ballast replacement, dimmable up to 40w fluorescent, to 15' high EA

26.83 Lighting fixtures, emergency lights, self contained fluorescent lamp pack EA

26.84 Lighting fixtures, exit lights, LED standard, single face EA

26.85 Lighting fixtures, exit lights, LED standard, double face EA

26.90 Circuit breaker, 120v, 1 pole, 15 to 50 amp EA

26.91 Circuit breaker, 240v, 2 pole, 15 to 50 amp EA

26.95 Disconnect electrical power service from system furniture, price per circuit removed to nearest junction box

EA

50.00 DIV 50 - INSTALL GOVERNMENT FURNISHED MATERIAL

50.01 Partition, demountable type, gypsum or metal LF

50.02 Door Frame, hollow metal or aluminum, excludes cutting opening EA

50.03 Door, wood or metal, in existing frame EA

50.04 Door hardware, lockset, cylindrical, in existing door, excludes door preparation EA

50.05 Door hardware, lockset, full mortise, in existing door, excludes door preparation EA

50.06 Door hardware, panic device, in existing door, excludes door preparation EA

50.07 Ceiling, acoustical tiles, in existing suspension system SF

50.08 Flooring, carpet, sheet goods, direct glue or stretched, contractor to supply all necessary items including adhesive, tack strip, any preparation of the floor surface

SY

50.09 Flooring, carpet, tile, contractor to supply all necessary items including adhesive, any preparation of the floor surface

SY

50.10 Flooring, resilient VCT, tile or plank, contractor to supply all necessary items including adhesive and preparation of the floor surface.

SF

50.11 Light fixture, fluorescent, lay in, any size, existing grid system, includes armored cable and connection to 15'

EA

50.12 Factor in percentage (+/- %) to be applied to Line Items for Other Than Normal Working Hours

(OTNWH)

Document C201-SB/Apr2014 R1 Page 1 of 29 (The Solicitation)

Indefinite Delivery Indefinite Quantity (IDIQ) General Construction, Repair and Alteration Contract for the Houston Zone

The Solicitation

Notice to Offerors of Total Small Business Set-Aside

The General Services Administration (GSA) is setting aside the contract under the following clause found in the Agreement:

52.219-6, Notice of Total Small Business Set Aside

Notice of Commercial Package Carriers

Because of increased security standards, commercial package carriers may experience delays in making deliveries to the address designated for receipt of offers. Offerors should take these facts into consideration when determining how and when to transmit offers to the office designated for receipt.

Table of Contents

I. General Information A. The Solicitation and Contract B. List of Solicitation Documents C. Authorized Representatives D. Pre-Proposal Conference E. Estimated Price Range F. FAR 52.228-1 Bid Guarantee G. FAR 52.236-27 Site Visit – Construction H. Receipt of Offers

II. Proposals A. Proposal Contents B. Proposal Format C. Price Proposal D. Technical Proposal E. Other Information to be Submitted with Proposal F. Requirements for Joint Venture Offerors

III. General Provisions A. Availability of Funds B. Requests for Clarification or Interpretation C. Notice to Small Business Firms D. Information Concerning the Disclosure of Solicitation Results E. Affirmative Procurement Program F. Notice Concerning Preparation of Proposals G. Bond Requirements H. Contractor Performance Information I. Safeguarding Documents Designated as Sensitive But Unclassified J. Future Indefinite Delivery Indefinite Quantity Contracts

IV. FAR/GSAR Solicitation Provisions

Document C201-SB/Apr2014 R1 Page 2 of 29 (The Solicitation)

A. FAR 52.215-1 Instructions to Offerors—Competitive Acquisition B. FAR 52.216-1 Type of Contract C. FAR 52.222-5 Davis-Bacon Act—Secondary Site of the Work D. FAR 52.222-23 Notice of Requirement for Affirmative Action to Ensure

Equal Employment Opportunity for Construction E. FAR 52.233-2 Service of Protest F. Buy American Act G. Buy American Act Exceptions H. FAR 52.252-1 Solicitation Provisions Incorporated by Reference

V. Additional Solicitation Provisions and Instructions A. Options B. Special Provisions for IDIQ Contracts C. FAR Provisions Incorporated by Reference D. FAR Provisions Full Text

VI. Method of Award A. Evaluation of Offers B. Determination of Responsibility C. Price Reasonableness D. Unbalanced Prices E. Total Evaluated Price F. Non-Price Factors G. Evaluation of Joint Venture Offerors

Document C201-SB/Apr2014 R1 Page 3 of 29 (The Solicitation)

I. General Information

I.A. The Solicitation and Contract

(1) This Solicitation is set-aside for Small Business Concerns, in accordance with FAR

19. This Solicitation sets forth requirements for proposals for a multiple award Indefinite Delivery Indefinite Quantity (IDIQ) Contract to provide for various construction, repairs, alterations and renovations to federally owned and leased facilities serviced by the Greater Southwest Region 7 of the General Services Administration (GSA) and located throughout the Houston Zone. Proposals conforming to the Solicitation requirements will be evaluated in accordance with the Method of Award set forth herein. The Government will award the Contract to the selected Offeror(s), subject to the conditions set forth herein.

The resultant contract(s) will have a Maximum Ordering Limitation (MOL) of $3,000,000 per contract per year. This represents the ordering capacity, but in no way obligates the Government to issue orders to that magnitude. The minimum guarantee is $2,000 per contract for the base year ONLY. The Government anticipates making up to five (5) awards under this single solicitation to Offerors who submit proposals which will provide the best value to the Government in terms of technical qualifications and price. The Government reserves the right to award a number of contracts outside this range.

The primary performance area is the Houston Zone. Included in this zone are the following counties: Angelina County, Aransas County, Austin County, Brazoria County, Brazos County, Calhoun County, Chambers County, Colorado County, Fayette County, Fort Bend County, Galveston County, Grimes County, Hardin County, Harris County, Houston County, Jackson County, Jasper County, Jefferson County, Lavaca County, Liberty County, Madison County, Matagorda County, Montgomery County, Nacogdoches County, Newton County, Orange County, Polk County, Refugio County, Sabine County, San Augustine County, San Jacinto County, Shelby County, Trinity County, Tyler County, Victoria County, Waller County, Walker County, Washington County, Wharton County.

The secondary performance area is the remainder of the contiguous United States. See section V.B.5. for complete a description of the primary and secondary performance areas and ordering procedures.

(2) Neither the Solicitation nor any part of an Offeror's proposal shall be part of the Contract except to the extent expressly incorporated therein by the Contracting Officer.

(3) The Offeror's proposal submitted in response to this Solicitation shall constitute a firm offer. No contract shall be formed unless and until the Contracting Officer has countersigned the SF 1442 submitted by an Offeror, and delivered to the Contractor a copy of the SF 1442 with original signatures together with the Agreement reflecting the Offeror's proposed prices.

I.B. List of Solicitation Documents

The Solicitation Documents are comprised of:

(1) The Solicitation

(2) Offeror Representations and Certifications Form

(3) Standard Form (SF) 1442 – Solicitation Offer and Award

Document C201-SB/Apr2014 R1 Page 4 of 29 (The Solicitation)

(4) The Agreement and Attachments to the Agreement No. GS-07P-14-HH-D-

(5) Hypothetical Statement of Work with Bid summary and drawings

(6) Region 7 Technical Specifications, titled “REGION 7 SPECS revised 10-28- 13”

(7) GSA Region 7 Construction Line Items 2013 (Pricing Form)

(8) List of Counties and Wage Determination numbers in the Houston Zone

(9) Map Showing Historical Spending Trends in the Houston Zone (for Information purposes ONLY)

I.C. Authorized Representatives

The following individuals are designated as the authorized GSA representatives under this Solicitation:

(1) Contracting Officer

Name: Becky Clark Address: 819 Taylor Street, Room 12B-395

Fort Worth, TX 76102 Telephone: (817) 978-7103

Email: Becky.clark@gsa.gov

(2) Alternate Point of Contact

Name: Carolina McGillick Address: 819 Taylor Street, Room 12B-394

Fort Worth, TX 76102 Telephone: (817) 850-5579

Email: Carolina.mcgillick@gsa.gov

I.D. Pre-Proposal Conference

A pre-proposal conference regarding this Solicitation is scheduled as follows:

Date: May 8, 2014 Time: 8:30 AM, CST

Location: GT Leland Federal Building 1919 Smith St., Room 16100 Houston, TX 77002 OR at the

Lanham Federal Building 819 Taylor St., Room 12A01 Fort Worth, TX 76102

NOTE: Offerors may attend at any of the 2 above locations.

Document C201-SB/Apr2014 R1 Page 5 of 29 (The Solicitation)

(1) Interested parties must notify the Alternate Point of Contact for further information about attendance and to confirm location, time, and date. Only those parties who have notified the Contracting Officer and provided necessary information in advance of the meeting will be allowed to attend in person. To request a reasonable accommodation due to a disability, contact the Contracting Officer. If unable to attend in person, contact the Alternate Point of Contact (#2 above) for teleconference information.

(2) Questions regarding this RFP will be addressed at a pre-proposal conference. All prospective Offerors shall submit in advance and in writing any questions they may have to Carolina McGillick at Carolina.mcgillick@gsa.gov. The submission of written questions will not preclude anyone from posing questions during the pre-proposal conference.

(3) Failure of a prospective Offeror to attend the pre-proposal conference will be construed to mean that the Offeror fully understands all requirements of the solicitation.

Prospective Offerors are advised that the pre-proposal conference will be held solely for the purpose of explaining the concepts involved in the hypothetical project, specifications, terms, and conditions of this solicitation.

(4) All prospective Offerors are advised that this solicitation will remain unchanged unless it is amended in writing. All amendments will be published on FedBizOpps.

I.E. Estimated Price Range

The individual task order(s) placed against the resulting IDIQ contract(s) will list the estimated price range when appropriate.

I.F. FAR 52.228-1 Bid Guarantee (SEP 96)

Bid Guarantee will be required at the Task Order level only. Only task orders over $150,000 will require a bid guarantee at the time of initial proposal.

(a) Failure to furnish a bid guarantee in the proper form and amount, by the time set for receipt of proposals, may be cause for rejection of the proposal.

(b) The Offeror shall furnish a bid guarantee in the form of a firm commitment, e.g., bid bond supported by good and sufficient surety or sureties acceptable to the Government, postal money order, certified check, cashier’s check, irrevocable letter of credit, or, under Treasury Department regulations, certain bonds or notes of the United States. The Ordering Contracting Officer will return bid guarantees, other than bid bonds—

(1) To unsuccessful offerors as soon as practicable after the receipt of proposals; and

(2) To the successful offeror upon execution of contractual documents and bonds (including any necessary coinsurance or reinsurance agreements), as required by the RFP as accepted.

(c) The amount of the bid guarantee shall be 20 percent of the proposal price or $3,000,000, whichever is less.

(d) If the successful offeror, upon acceptance of its proposal by the Government within the period specified for acceptance, fails to execute all contractual documents or furnish executed bond(s) within 10 days after receipt of the forms by the offeror, the Ordering Contracting Officer may terminate the contract for default.

Document C201-SB/Apr2014 R1 Page 6 of 29 (The Solicitation)

(e) In the event the contract is terminated for default, the Offeror is liable for any cost of acquiring the work that exceeds the amount of its proposal, and the bid guarantee is available to offset the difference.

I.G. FAR 52.236-27 Site Visit - Construction (FEB 95)

(1) The clauses at FAR 52.236-2, Differing Site Conditions, and FAR 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation and are in the attached Agreement. Accordingly, Offerors are urged and expected to inspect the site where the work will be performed prior to the issuance of a Task Order.

I.H. Receipt of Offers

(1) In order to be considered for award, offers conforming to the requirements of the Solicitation must be received at the following office no later than 2:00 pm Central Standard Time on the following date and at the following address:

Date: June 4, 2014 Address: General Services Administration

ATTN: Carolina McGillick (7PQA) 819 Taylor Street, Room 12B-394 Fort Worth, TX 76102

(2) Offers sent by commercial package delivery and hand delivery shall be deemed received as of the date and time of delivery to the office designated for receipt of offers.

(3) Offers sent by United States Mail shall be deemed timely if delivered to the address of the government installation designated for receipt of offers on or before the date established for receipt of offers.

(4) Any questions regarding this solicitation must be submitted in writing to Carolina McGillick at Carolina.mcgillick@gsa.gov no later than May 15, 2014.

II. Proposals

II.A. Proposal Contents Proposals shall consist of the following documents, completed and executed in accordance with this Solicitation:

1) Price Proposal

a) Standard Form (SF) 1442 signed by authorized representative, with Amendments (if applicable) acknowledged, signed, and dated.

b) GSA Region 7 Construction Line Items 2013 (Pricing Form), including options and factors to be applied to line items for “Other than Normal Working Hours” (OTNWH). Please include a PDF file containing your line item prices as well as the Excel spreadsheet in the flash drive.

c) Pricing for the Hypothetical SOW using Bid Summary sheet. It may be a PDF file.

2) Other Requirements

Document C201-SB/Apr2014 R1 Page 7 of 29 (The Solicitation)

a) Offeror Representations and Certifications Form (C301)

b) Signed executed Joint Venture or partnership agreement (with original signatures), if applicable.

3) Technical Proposal (see Section II.D. below for complete description).

II.B. Proposal Format

To aid in evaluation of proposals, each proposal shall be clearly and concisely prepared in writing: include all information required by the solicitation, with pages numbered and logically assembled. Each proposal shall identify name of Offeror, date of submission, and solicitation number.

Each proposal shall consist of three separate electronic files; each individually titled (i.e., Pricing Proposal, Offeror Representations and Certifications and Technical Proposal).

The proposal package shall fit paper size 8-1/2” x 11” when printed; in a font not less than 10-point in size. Font style is optional. The Technical Proposal shall be no more than 100 pages long.

II.C. Price Proposal & Other Requirements

(1) Contents

The Price Proposal shall consist of the signed SF 1442 and the Agreement, with prices for each line item for the base year and each of the option years. A factor to be applied to line items for other than normal working hours (OTNWH) for the base year as well as the option years shall be included in the spaces indicated on the GSA Region 7 Construction Line Items 2013 (Pricing Form). And a copy of the pricing for the Hypothetical SOW (Bid Summary).

The offeror’s proposal must demonstrate an effective and efficient cost approach for accomplishing the stated requirements. The line item prices on each proposal for the base and all option years will be totaled to come up with a total overall price for evaluation purposes. Price proposals will be evaluated to avoid “unbalanced pricing” as per FAR 15.404-1. All offers will be analyzed to determine if the prices are unbalanced. An offer may be rejected if the Government determines that the lack of balance poses an unacceptable risk to the Government.

The factor to be applied to line items for Other Than Normal Working Hours (OTNWH) will also be considered and evaluated as part of the price analysis. The hypothetical project pricing will also be considered and price analysis performed.

If the Offeror is proposing a Contractor Team Arrangement in accordance with FAR Subpart 9.601(1), either as a Joint Venture or Partnership:

All offers submitted must include a copy of an executed joint venture or partnership agreement (with original signatures) which fully discloses the legal identity of each member, the relationship

Document C201-SB/Apr2014 R1 Page 8 of 29 (The Solicitation) between the members, the form of ownership of each member, and any limitations on liability or authority for each member.

An authorized representative of each member of the joint venture or partnership must sign the SF1442 accompanying an offer regardless of any agency relationship between the members.

(2) Qualifications, Exclusions and Conditions

If the Offeror communicates in its proposal any qualifications, exclusions, or conditions to the proposed prices not provided for in the Contract Documents, the Contracting Officer may reject the proposal and exclude the Offeror from further discussions.

II.D. Technical Proposal

The Technical Proposal shall include the information requested below for the non-price factors described below. These factors are listed in order of importance.

(1) Management Plan

This factor is comprised of the offeror's management capability and ability for planning, organizing and controlling the execution of construction and repair and alteration projects simultaneously, including scheduling work, coordination of subcontractors, trades and suppliers, minimization of delays and compliance with tenants’ needs. It includes: the coordination to assure compliance with contract requirements; a safety plan, technique for dealing with issues, problems, questions, emergencies and other areas of concern.

Submittal Requirement: The Offeror shall submit a narrative describing their:

Plan for organizing and controlling projects.

Plan to manage sub-contractors.

Safety and Health Plan.

Sustainability and Waste Management Plan.

Quality Control Plan.

The offeror shall also submit a list of proposed sub-contractors, and length of partnership.

(2)Experience

This factor considers the quality of the offeror's experience in carrying out work of a similar nature, in the same geographic location, with respect to construction and repair/alterations. Considerations will be given to success in areas of technical quality, delivery, timeliness and completion within budget.

Submittal Requirement: Provide samples of five (5) projects successfully completed in the past five (5) years from the date of issuance of this solicitation, and within this zone, or within a 50- mile radius of this zone. Three (3) of the five projects submitted should meet the definition of similar. The definition of "similar” for evaluation purposes is a task order/project involving successful repair and alteration valued at a minimum of $15,000 in a fully occupied building with executive space build-out. At least one (but as many as possible) should be examples of managing high end wood work, or Intrusion Detention and Prevention (IDP) projects, or cabling projects, or projects involving detention or law

Document C201-SB/Apr2014 R1 Page 9 of 29 (The Solicitation) enforcement work.

(3)Past Performance

Information to be evaluated includes timeliness of delivery/performance, including adherence to contract schedules and timely submission or performance of required tests and submittals. Resolution of disputes and delays, number of contract extensions, conformance to contract requirements, including quality of workmanship, ability to correct deficiencies in a timely manner, number and extent of warranty problems. The offeror's history for reasonable and cooperative behavior and commitment to customer satisfaction;

and generally, the offeror's business-like concern for the interest of the customer.

Submittal Requirement: List five (5) construction projects that your firm has successfully completed over the last 5 years from the date of issuance of this solicitation, and within this zone, or within a 50-mile radius of this zone. All 5 projects must, at a minimum, contain the following:

- Project title and contract number

- Offeror’s role in the contract (prime or subcontractor); if subcontractor, list name, address, and phone number of prime contractor

- Name of person representing the customer who is familiar with the project and their current phone number and email address

- Project description and place of performance

- Contract period

- Project size in square footage for construction services

- Description of work done directly by offeror

- Description of work done by subcontractor(s), if applicable

- Original construction award amount

- Actual completion amount

- Number of customer initiated change orders and number of contractor initiated change orders

- Planned completion date and actual completion date

- Amount of liquidated damages assessed

- Name of offeror’s project manager for the project

At least 3 of the above projects shall demonstrate the offeror's past performance with projects of similar scope/type of work items. (“Similar” is defined above in II.D.(2)).

NOTE: According to FAR 15.305(a)(2)(iv); Offerors will not be rated favorably or unfavorably for having no relevant past performance. A rating of Neutral will be given for this evaluation factor if the offeror has no relevant past performance.

(4) Quality and Accuracy of Hypothetical Proposal

This factor is comprised of the offeror's understanding and response to the hypothetical proposal and the price reasonableness of their hypothetical bid. This factor will be evaluated to determine the offeror’s understanding of the Hypothetical requirement, their plan to successfully complete the SOW, and their thoroughness in responding to the requirements.

Submittal Requirement:

Document C201-SB/Apr2014 R1 Page 10 of 29 (The Solicitation)

- Hypothetical price proposal (Include a copy in both Price Proposal and Technical Proposal)

- Narrative explaining methodology or approach to hypothetical performance

- Submittal log as defined in the hypothetical bid proposal

(5) Qualifications and Experience of Key Personnel

This factor considers the education, knowledge, experience, and expertise of the offeror’s key personnel proposed to be assigned directly to the contract. Key personnel include, Project Manager or Coordinator, On-Site Superintendent, Construction Supervisor, and Inspection and Testing Agent(s).

Submittal Requirement: Offerors are required to show a staffing plan that indicates responsibilities of key personnel and how they interface with major subcontractors.

- Offerors are required to provide the information listed below for all key personnel:

Names of key personnel and title Training, Certificates/Licenses, Trade associations belonging to and/or involved with Experience and duties

Amount of time individual will dedicate to projects arising from this contract State this person's signature authority for the contractor and restrictions, if any

- List 3 similar projects on which key personnel have successfully completed in the last 5 years from the date of issuance of this solicitation. All 3 projects must be submitted in the format listed below (each key personnel member must be listed on at least 3 projects, one project can reference multiple members of the key personnel):

Project title and contract number Key personnel who performed on this contract, and what role they played Contract period and project size in square footage for construction services

Name and current phone number of customer representative most familiar with the project Project description Completed construction amount and amount of liquidated damage assessed, if any

If experience of key personnel was obtained while in the employment of another firm, identify the firm and a representative of that firm by name, address, and current phone number.

“Similar” is defined above in II.D.(2).

(6) Evidence of Local Office

Each offeror will be evaluated based on the location of its operations (i.e. buildings, offices, and key personnel). For the purpose of this solicitation, an office based out of a private residence or out of office space assigned under a separate contract (i.e.

Government furnished office space) is not considered to be a bona fide office.

Evidence of a bona fide place of business, within the zone (or within a 50-mile radius of this zone) is required for a satisfactory or higher rating in this factor.

Document C201-SB/Apr2014 R1 Page 11 of 29 (The Solicitation)

II.E. Other Information to be Submitted with Proposal

(1) Representations and Certifications

Offerors submitting a proposal in response to this Solicitation shall complete electronic Annual…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .