Text version
FUTURE
TENANT PROJECT
SCOPE
E
LEVATO
R S
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
PROJECT
SCOPE
N O
R T
H
Roof Key Plan - Stokes Roof Plan not to scale
ARCHITECTURAL
INTERIOR DESIGN
GENERAL
A0-00 Reference Information
A0-01 Partition Types
A1-01 Partial 13th Floor Demolition Plan
A2-01 Partial 13th Flr. Plan
A2-02 Enlarged Plans
A3-01 Partial 13th Flr. Reflected Ceiling Plan
A3-02 Ceiling Details
A3-03 Ceiling Details
A4-01 Interior Elevations
A4-02 Interior Elevations
A5-01 Interior Sections & Details
A5-02 Interior Sections & Details
A5-03 Interior Sections & Details
A6-01 Door Schedule, Types & Details
A8-01 Partial Roof Plan
ID-01 Finish Plan, Legend & Schedule
TS-1 Title Sheet
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
PREPARED BY:
ARCHITECT
p:
f:
contact:
MEP ENGINEER
p:
contact:
GENERAL SERVICES ADMINISTRATION
GREAT LAKES REGION
REGION 5
280 SOUTH DEARBORN STREET
CHICAGO, ILLINOIS 60604
PREPARED FOR:
LOCATION PLAN:DRAWINGS:
GENERAL NOTES:
contact:
GSA Project Manager, PM:
John Bolovan
GSA Contracting Officer, CO :
Marilyn Roldan
GSA Contracting Officer Representative, COR:
Elbert R. Regacho
GSA Facility Manager, FM:
Karen Weaver
NWS Contact Persons:
Benjamin Dunford Gary Garnet
GOVERNMENT TEAM MEMBERS
STRUCTURAL ENGINEER
Barber & Hoffman 2217 E 9th Suite 350
Cleveland, OH 44115 p: 216- 875-0100 contact: Brad Boomer
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT.
COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT
TO UNAUTHORIZED PERSONS IS PROHIBITED.
Do not remove this notice.
Properly destroy or return documents when no longer needed.
Carl B. Stokes US Court House
801 West Superior Avenue
TS-1
EV
Title Sheet
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St
Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
NOAA Office Relocation, 13th Floor Carl B. Stokes US Court House 801 West Superior Avenue Cleveland OH 44113
Final Design Submittal
Perspectus Architecture
13212 Shaker Square, Suite 204
216.752.3833
Tim Huffman
Cleveland, Ohio 44120
Fredrick, Fredrick & Heller Engineers
672 E Royalton Rd
440.546.9696
Mech/Plumb: Brian Widowski
Broadview Heights, Ohio 44147
216.752.1800
Elec: Todd Gienger
1. All Dimensions and Quantities shall be verified at the job by the contractor and each subcontractor.
All contractors shall notify Contracting Officer Representative (COR) and Architect of discrepencies before proceeding with the work.
LS-01 13th Floor Life Safety Plan
FIRE PROTECTION
FP1-00 Partial 13th Floor Fire Protection Demolition Plan FP1-01 Partial 13th Floor Fire Protection Plan
PLUMBING
P1-00 Plumbing Legend P1-01 Partial 12th Floor Plumbing Demolition Plan P1-02 Partial 12th Floor Plumbing Plan P1-03 Partial 13th Floor Plumbing Demolition Plan P1-04 Partial 13th Floor Plumbing Plan P1-05 Partial Lower Level Three Plumbing Plan
ELECTRICAL
E0-01 Electrical and Technology Legend E0-02 Lighting Fixture Schedule E1-01 Site Electrical Plan E1-02 Partial Lower Level Three Technology Key Plan E1-03 Partial Lower Level Three Electrical and Technology Key Plan E1-04 Partial 13th Floor Electrical and Technology Key Plan E1-05 Partial 21st Floor Electrical and Technology Key Plan E2-01 Partial 13th Floor Electrical Demolition Plan E3-01 Partial 13th Floor Lighting Plan E4-01 Partial 13th Floor Power Plan E4-02 Partial 13th Floor Power Plan E5-01 Partial 13th Floor Communication Plan E6-01 Partial 13th Floor Fire Alarm and Security Plan E7-01 Partial 13th Floor Mechanical Connections Plan E8-01 Partial 22nd Floor Electrical and Technology Plan E8-02 Partial 22nd Floor Lightning Protection System Plan E9-01 N.O.A.A. One-Line Diagram E9-02 Panel Board Schedules E9-03 Panel Board Schedules E10-01 Fire Alarm Riser Diagram E10-02 Access Control Typical Wiring Diagrams E10-03 Access Control Typical Wiring Diagrams E11-01 Grounding Details E11-02 Generator and ATS Remote Annunciator Wiring Diagram E11-03 UPS Remote Annunciator Wiring Diagram E11-04 Electrical and Technology Details E11-05 Electrical and Technology Details
NORTH
HEATING, VENTILATING AND AIR CONDITIONING
M1-00 Mechanical Legend M1-01 Mechanical Schedule M1-02 Mechanical Schedule M1-03 Mechanical Details M1-04 Mechanical Details M1-05 Mechanical Controls M2-00 Partial 13th Floor HVAC Demolition Plan M2-01 Partial 13th Floor HVAC Plan M2-02 13th Floor Equipment Room HVAC Plan M2-03 Mechanical Room HVAC Piping Plans M2-04 Partial 22nd Floor Two Mechanical Plan
STRUCTURAL
S1-00 Structural General Notes S8-01 Rooftop Antenna Support Framing Plan
R E G I S
T E
RED ARCH
I T E C T
WILLIAM
C.
AYARS
S T
A
TE
OF OH
I O
William C. Ayars, License #7259 Expiration Date 12/31/2015
Arch Job No. 15-002
E F G H
J
K
G.1
ZZ
YY
H.5
3.5
WW
XX
WW.3
AA
BB
CC
DD
EE
FF
GG
HH
JJ
LL
KK
154 SF
MIC
Office 13-12
124 SF
WCM
Office 13-13
121 SF
SOO
Office 13-14
119 SF
ESA
Office 13-15
439 SF
Elec./ Tech.
13-16A
123 SF
RMS
Office 13-17
770 SF
Equip.
13-07
116 SF
Elec.
13-08
124 SF
Multipurpose Rm.
13-02
2257 SF
Future Tenant 1300X
134 SF
Training 13-09
171 SF
Collaboration Area 13-11
134 SF
Ready Rm
13-06
147 SF
Copy/ Stor.
13-03
213 SF
Reception 13-01
382 SF
Conference Rm.
13-05
141 SF
Vest.
13-00
S torage &
Lg. Lockers
E
E
Common Path of Travel = 92'
Total Travel D istance = 177' to
Exit
Common Path of Travel = 87'
PROJECT LIMIT LINE'
PROJE
CT L
IM
IT
L
IN
E'
215 SF
Bldg.
Corr 13-18
540 SF
Elec./ Tech.
13-16B
340 SF
Hall 13-10
527 SF
Hall 13-04
PROJECT LIMIT
DN
139 SF
Storage 13-19
Life Safety Legend
E
EXISTING 2 HR FIRE BARRIER
NEW 1 HR FIRE PARTITION
FIRE EXTINGUISHER
EXIT
EXIT SIGN
EGRESS PATH OF TRAVEL
PROJECT LIMIT LINE
Illuminated face
Directional arrow
Refer to engineering drawings for mounting type
FUTURE
TENANT PROJECT
SCOPE
ELEVATORS
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
R E G
I STERED ARCH
I T E C T
WILLIAM
C.
AYARS
ST
AT
E OF OHIO
William C. Ayars, License #7259 Expiration Date 12/31/2015
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Carl B. Stokes US Court House
801 West Superior Avenue
LS-01
Author
13th Floor Life Safety Plan
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
Scale
4' 8' 16'
1/8" = 1'-0"
Partial 13th Floor Life Safety Plan
Existing Building Code Data Occupancy Classification
B - Business Type of Construction
1-B Modified (LSC Type 1 - 332) Sprinkler System
Fully Sprinklered Fire Ratings
Exterior Load Bearing Walls- 3 hrs Exterior Non-load Bearing Walls - 1 hr Interior Load Bearing Walls, Partitions, Columns, Girders, Trusses and Framing supporting more than one floor - 3 hrs supporting one floor or roof only - 2 hrs Fire Walls and Party Walls - 3 hrs Floor Construction (UL D925) - 2 hrs Roof Construction (UL P719)
15' or less in height - 1.5 hrs more than 15' to less than 20' - 1 hr 20' or more in height - 0 hrs
Fire Separation Assemblies Exit Enclosures - 2 hrs Shafts - 2 hrs Mixed Use and Fire Areas - 3 hrs Others - 1 hr
Fire Partitions Exit Access Corridors - 0 hrs Tenant Space Separations - 1 hr
Smoke Barriers - 1 hr Other Non-load Bearing Partitions - 0 hrs
NOAA Tenant Code Data Project Description
6735 sf interior renovation Applicable Codes
2015 NFPA Life Safety Code 2012 International Building Code 2015 ABA Accessibility Standards
Occupancy Classification B - Business (LSC 6.1.11.1)
Sprinkler System Fully Sprinklered
Occupant Load (LSC 7.3.1.2) 6735 gsf / 100 gsf = 68 occupants
Number of Means of Egress:
2 (LSC 7.4.1.1)
Egress Capacity (Corridors) .02" x 68 = 13.6" (LSC 7.3.3.1)
Minimum Corridor/Passageway (Hall) Width -
44" (LSC 38.2.3.2)
Maximum Length of Dead End Corridor -
50' (LSC 38.2.5.2.1)
Maximum Common Path of Travel -
100' (LSC 38.2.5.3.1)
Maximum Travel Distance to Exit -
300' (LSC 38.2.6.3)
Emergency Lighting -required (LSC 38.2.9.1)
Fire Alarm System -required (LSC 38.3.4.1)
Portable Fire Extinguishers -required (LSC 38.3.5)
Subdivision of Building Spaces:
No special requirements (LSC 38.3.7)
Horizontal Sliding Doors permitted for less than 10 occupants (LSC 7.2.1.4.1(4)(d))
Future Tenant Code Data Project Description
2257 sf Future Interior Renovation Applicable Codes
2015 NFPA Life Safety Code 2012 International Building Code 2015 ABA Accessibility Standards
Occupancy Classification B - Business (LSC 6.1.11.1)
Sprinkler System Fully Sprinklered
Occupant Load (LSC 7.3.1.2) 2257 gsf / 100 gsf = 20 occupants
Number of Means of Egress: 1 (LSC 38.2.4.2))
Egress Capacity .02" x 20 = 4" (LSC 7.3.3.1)
Maximum Common Path of Travel - 100' (LSC 38.2.5.3.1) Maximum Travel Distance to Exit - 300' (LSC 38.2.6.3)
N O
R T
H
GENERAL NOTES
1. See drawing A2-01 for fire rated partition types and drawing A0-01 for partition construction.
2. See drawing A2-01/ A2-02 for fire extinguisher and cabinet locations.
3. See drawing E3-01 for exit sign types, mounting types, and locations.
4. See drawing A3-01 for dimensional locations of ceiling mounted exit signs.
5. See architectural elevations A4-01 and A4-02 for dimensional locations of wall mounted exit signs.
5/8" Type X GYP BD
MTL studs
Control joint, both sides
MAX
1/2"
5/8" Type X GYP BD
TYP of all control joints located in rated wall assemblies.
MAX
1/2"
MAX
1/2"
1 7/8"
Note: Acoustical insulation may occur, see partition types
Joint REINF
ACOUS INSUL
Back to back boxes NOT permitted Stagger Boxes
UNO
6"
Partition assembly
Door frame
TYP of all frames that occur at room corner locations, UNO
Joint compound and tape
5/8" GYP BD
MTL studs
Control joint
Note: Acoustical insulation may occur, see partition types
TYP of all control joints located in non-rated wall assemblies.
A
See specifications for sealant type.
All joints 1" wide or more are to be laid up in beads and tooled to profile indicated.
All joints are to be primed before bond breaker rod is installed.
Install bond breaker rod with roller to proper depth. No sharp tools permitted.
1.
2.
3.
4.
Notes:
B C
Wall material varies
07 92 00 - Bond breaker rod
07 92 00 - Sealant
Joint Schedule Dimensions
A B C
3/8" 1/8" 1/4"
1/2" 1/8" 3/8"
5/8" 1/8"
3/4" 1/8"
7/8" 1/8"
1" 1/8"
3/8"
3/8"
3/8"
3/8" anchor bolt above air conditioning acoustic(al) acoustical ceiling tile adjacent above finish floor alternate aluminum anodized approximate architect(ural) automatic
AB
ABV
A/C
ACOUS
ACT
ADJ
AFF
ALT
ALUM
ANOD
APPROX
ARCH
AUTO
board between building block(ing) bulkhead beam bottom bridging bearing brick basement built-up roofing
BD
BETW
BLDG
BLK
BLKHD
BM
BOT
BRDG
BRG
BRK
BSMT
BUR
CFM
CG
CI
CJ
CLG
CL
CLR
CLL
CNTR
CMU
CO
COL
CONC
CONN
CONST
CONT
COORD
CORR
CS
CTR
CL
cubic feet per minute corner guard cast iron control joint ceiling closet clear contract limit line counter concrete masonry unit cased opening/clean out column concrete connection construction continuous coordinate corridor course center
D
DBL
DEG
DEMO
DIA
DIM
DISP
DN
DR
DS
DET
DWG
DWR
depth double degrees demolition diameter dimension dispenser down door down spout detail drawing drawer each electrical contractor exterior insulation and finish system expansion joint electric elevator/elevation emergency equal equipment exposed structure existing to remain each way electric water cooler exhaust existing expansion exposed exterior
EA
EC
EIFS
EJ
ELEC
ELEV
EMERG
EQ
EQUIP
ES
ETR
EW
EWC
EXH
EXIST
EXP
EXP'D
EXT
fire alarm face brick fan coil unit face to face floor drain foundation fire extinguisher fire extinguisher cabinet fire hose cabinet finish floor fluorescent fire resistant
FA
FB
FCU
F/F
FD
FDN
FE
FEC
FHC
FIN
FLR
FLUOR
FR
GA
GALV
GC
GL
GR
GWB
gauge galvanized general contractor glass grade gypsum board
HB
HC
HDBD
HDCPD
HDWR
HDWD
HM
HORIZ
HPDL
HR
HT
HTG
HTR
HVAC
HW
HWH
hose bibb hollow core hardboard handicapped hardware hardwood hollow metal horizontal high pressure decorative laminate hour height heating heater heating, ventilation air conditioning hot water hot water heater
ID
IN
INCL
INSUL
INT
inside diameter inch include (inclusive) insulation interior janitor joist
JAN
JST
knock down knock out
KD
KO
L
LAM
LAV
LB
LF
LIM
LT
LTG
LVR
length (long) laminate(d) lavatory pound linear feet (foot) limited light lighting louver
MARB
MAS
MAT
MAX
MECH
MEMB
MFR
MH
MIN
marble masonry material maximum mechanical membrane manufacturer manhole minimum not applicable not in contract number nominal not to scale
N/A
NIC
NO
NOM
NTS
overall on center on center above finish floor outside diameter overhead door opposite hand overflow roof drain out to out opening opposite optional
OA
OC
OCAFF
OD
OHDR
OPH
OVRD
O/O
OP'G
OPP
OPT
PLBG
PMLD
PNL
PLYWD
POL
PP
PR
PREFIN
PREFAB
PROJ
PSC
PSF
PSI
PT
PTD
PTN
PVC
PVMT
plumbing premoulded panel plywood polished push plate pair prefinished prefabricated projection pre-stress concrete pounds per square foot pounds per square inch point painted partition polyvinylchloride pavement
QTY quantity
R
RA
RAD
RAG
RD
REC
REF
REG
REINF
riser return air radius return air grille roof drain receptacle refrigerator register reinforcement solid core schedule smoke detector saddle section sheet similar stand pipe specifications speaker sprinkler single ply roofing square square inch square yard stainless steel/ slop sink standard steel storage structure(al) suspended systems
SC
SCHED
SD
SDL
SECT
SHT
SIM
SP
SPEC
SPKR
SPKLR
SPR
SQ
SQ IN
SY
SS
STD
STL
STOR
STRUC
SUCP
SYS
T T/G or T&G
TD
TEL
TEMP
TEMP'D
THK
THLD
TOC
TOS
TOD
TOM
TOJ
TOP
TOW
TYP
thread tongue and groove trench drain telephose temporary tempered thick threshold top of concrete (top of curb) top of steel top of deck top of masonry top of joist top of parapet top of wall typical undercut underground unfinished unlimited unless noted otherwise urinal
UC
UG
UNFIN
UNLIM
UNO
UR
VERT
VEST
VIF
vertical vestibule verify in field
W W/ W/O W/W
WC
WD
WH
WIN
WG
WT
WWF
width with without wall to wall water closet wood water heater window wire glass weight welded wire fabric
YD yard
ABBREVIATIONS
C/C
CAB'T
CAD
CB
CEM
CL or center to center cabinet cadmium catch basin cement center line fire-retardant treated fire-retardant treated wood feet footing furring fire valve cabinet
FRT
FRTWD
FT
FTG
FURR
FVC
MISC
MO
MTD
MTG
MTL
MULL
miscellaneous masonry opening mounted mounting metal mullion
PBD
PCF
PERIM
PG BD
PL
PLAS
particle board pounds per cubic foot perimeter peg board plate plastic
REINF
REQ'D
RES
RET
REV
RM
RO
RVS
reinforcement (reinforcing) required resilient return revised (revision) room rough opening reverse
I. GENERAL NOTES
1. Do not scale drawings. Contractor(s) are to verify site dimensions and conditions prior to work.
2. Construction shall be in accordance with the requirements of the applicable codes including accessibility standards and the requirements of “Architectural Barriers Act.”
3. Contractor(s) shall visit the site and correlate the requirements of the documents with the existing conditions.
4. Drawings are diagrammatic and since existing conditions, including areas above accessible ceilings may affect new work, the contractor shall coordinate and alter new work to properly fit the existing conditions. The work shall be performed at no extra cost. The contractor shall verify all conditions and dimensions at the job site prior to the start of construction. If discrepancies are found, the architect shall be notified for clarification before commencing with the work.
5. Details not shown are similar in character to those shown.
When specific dimensions, details, or design intent cannot be determined, consult the architect before proceeding with the work.
6. Some masonry and lumber dimensions shown on the drawings are nominal dimensions. Contractor(s) shall coordinate actual dimensions with the job conditions. Report all discrepancies to the architect.
7. Existing conditions shown on this drawing are not guaranteed to be complete. The contractor(s) shall field verify all existing conditions, dimensions, and materials required for the contracted work. Report all discrepancies to the architect prior to fabrication and erection.
8. The term ‘patch to match’ or ‘cutting and patching’ denotes that repair work is necessary to construct a floor, base, wainscot, wall or ceiling to match its adjacent surface, texture, material, finish and color of adjacent existing surfaces.
9. If materials suspected of containing hazardous materials are encountered, DO NOT DISTURB; immediately notify the architect and owner.
10. Where existing partitions or services have been removed, or new services penetrate existing surfaces, the openings shall be patched to match the existing surface finish, texture, and sheen.
11. Where new openings occur in structural bearing wall, contractor is responsible for temporary supports and/or shoring as required for installation of lintels.
12. Where existing doorways are to be filled in, contractor is responsible for field verifying wall widths.
13. The General Contractor is responsible for installation of all access doors, access panels and frames, including, but not limited to those specific in the construction documents and furnished by other contractors. All access doors and panel locations to be coordinated and approved by the architect prior to installation. The general contractor is responsible for painting all access panels and access doors. General contractor is responsible for coordinating all paint colors with the architect prior to commencing with the work.
II. FIRE RESISTANCE RATING
1. Fire rating indicated on a wall shall mean the entire length and height of wall to be fire rated.
2. All piping, ducts, cabinets, etc. that penetrate walls shall be installed in a manner that wil preserve the fire resistance rating of that wall.
3. Preserve all fire resistant ratings of existing wall unless otherwise noted.
III. DIMENSIONING
1. Interior partitions are dimensioned to face of gypsum board exclusive of finish material, such as ceramic tile or wood paneling. The contractor shall coordinate finish dimensions with finish schedule when critical to the installation of millwork or equipment.
CONT stud track
CONT stud track
Channel stud REINF as required at wall mounted devices
Midpoint at door opening
CONT channel REINF
Double studs at jamb opening 20 GA MIN, 18 GA at openings over 3'-0"
Door Opening
Door Opening
EXIST STRUC above
GYP BD control joint
Hollow MTL frame
MTL studs coped to fit
TYP MTL studs
Ceiling may occur
STANDARD SYMBOLS
Building, wall and detail section mark
Interior/exterior elevation reference
Enlarged plan or detail reference
Column reference grids
Revision reference number
Partition type
Window type
New level line, control point, or datum
New door
Indicates drawing sheet on which plan/detail is shown.
Indicates detail number
Indicates drawing sheet on which elevation is shown
Indicates elevation number
Indicates drawing sheet on which section is shown
Indicates section number Door number
XX
A
A2-11
A2-1
A2-1
A
FUTURE
TENANT PROJECT
SCOPE
ELEVATORS
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
4' -0
1' -6
" Receptacle
087200 Push plate
150000 Thermostat
150000 Humidistat
8" 8" 8"
4' -0
167200 Phone jack
160000 Light switch
4' -0
PTD-1
4' -6
RH-1
4' -0
SD-1
4' -6
Fire extinguisher
105220 - Cabinet may occur
STANDARD MOUNTING HEIGHTS
5' -6
1' -0
R E G
I STERED ARCH
I T E C T
WILLIAM
C.
AYARS
ST
AT
E OF OHIO
William C. Ayars, License #7259 Expiration Date 12/31/2015
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Carl B. Stokes US Court House
801 West Superior Avenue
A0-00
Author
Reference Information
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
Scale
4" 8" 16"
1 1/2" = 1'-0"
Fire Resistant Control Joint A2
Scale
4" 8" 16"
1 1/2" = 1'-0"
TYP Acoustical Part. Intersection B3
Scale
4" 8" 16"
1 1/2" = 1'-0"
TYP Electrical / Junction Box B2
Scale
4" 8" 16"
1 1/2" = 1'-0"
TYP Frame Location C2
Scale
4" 8" 16"
1 1/2" = 1'-0"
TYP GWB BD Control Joint A3
Scale
6" 1' 2'
12" = 1'-0"
TYP Sealant Detail B1
Scale
2' 4' 8'
1/4" = 1'-0"
TYP GWB Detail C1
TOILET ACCESSORY SCHEDULE
Rm. No. Rm. Name Code Description Comments
13-02 Multipurpose Rm. SD-1 Soap Dispenser - Surface mounted Contractor Furnished Contractor Installed 13-02 Multipurpose Rm. PTD-1 Paper Towel Dispenser - Surface mounted Contractor Furnished Contractor Installed 13-02 Multipurpose Rm. HD-1 Automatic Hand Dryer - Surface mounted Owner Furnished Contractor Installed.
Coordinate with Engineering drawings.
13-02 Multipurpose Rm. FM-1 Framed Mirror Contractor Furnished Contractor Installed 13-06 Ready Rm SD-1 Soap Dispenser - Surface mounted Contractor Furnished Contractor Installed 13-06 Ready Rm PTD-1 Paper Towel Dispenser - Surface mounted Contractor Furnished Contractor Installed
Provide and install (Qty. 2) Robe hooks RH-1 at the following Offices: 13-12, 12-13, 13-14, 13-15, 13-17 Locate centered on wall behind door in open position. One at 4'-6"H, One at 5'-6"H.
Scale
16" 32" 64"
1 1/2" = 1'-0"
Typ. Acoustic Sealant B4
6"
GWB AS SCHEDULED
SUBSTRATE
FLEXIBLE FIBER BOARD
INSULATION WHERE SCHEDULED,
NOM. THICKNESS TO MATCH
FRAMING DEPTH
FLOOR OR ROOF
STRUCTURE ABOVE
2 1/8"
VARIES, REFER TO SCHEDULE
LINE OF FINISHED CEILING,
HEIGHT VARIES, REFER TO RCP
TOP T1
METAL FRAMING AS SCHEDULED,
CLIPPED BACK TO FACE OF
SUBSTRATE
6"
GWB AS SCHEDULED, INSTALL
ON ROOM SIDE OF STUDS
METAL STUDS AS
SCHEDULED
FLOOR OR ROOF
STRUCTURE ABOVE
VARIES, REFER TO SCHEDULE
SOUND ATTENUATION
INSULATION WHERE SCHEDULED,
NOM. THICKNESS TO MATCH
FRAMING DEPTH
METAL STUD RUNNER
4 1/4"
LINE OF FINISHED CEILING,
HEIGHT VARIES, REFER TO RCP
TOP T2
NOTE: REFER TO PARTITION SCHEDULE FOR TOP TERMINATION OF
INSULATION. IF NOT NOTED TO STRUCTURE TERMINATE MATERIAL MIN. 6"
ABOVE HIGHEST ADJACENT CEILING.
TOP T3
GWB BOTH SIDES AS SCHEDULED
METAL STUDS AS SCHEDULED
FLOOR OR ROOF
STRUCTURE ABOVE
VARIES, REFER TO SCHEDULE
SOUND ATTENUATION
INSULATION WHERE SCHEDULED,
NOM. THICKNESS TO MATCH
FRAMING DEPTH
METAL STUD RUNNER
4 7/8"
ACOUSTIC JOINT BOTH SIDES
NOTE: REFER TO PARTITION SCHEDULE FOR TOP TERMINATIONS OF GWB
AND INSULATION. IF NOT NOTED TO STRUCTURE TERMINATE MATERIAL
MIN. 6" ABOVE HIGHEST ADJACENT CEILING.
LINE OF FINISHED CEILING
HEIGHT VARIES, REFER TO RCP
BASE B1
GWB AS SCHEDULED
METAL FRAMING AS SCHEDULED,
CLIPPED BACK TO FACE OF
SUBSTRATE
SUBSTRATE
FLEXIBLE FIBER BOARD INSULATION
WHERE SCHEDULED, NOM. THICKNESS
TO MATCH FRAMING DEPTH
FLOOR STRUCTURE
2 1/8"
VARIES, REFER TO SCHEDULE
BASE B2
GWB AS SCHEDULED, INSTALL
ON ROOM SIDE OF STUDS
METAL STUDS AS
SCHEDULED
VARIES, REFER TO SCHEDULE
SOUND ATTENUATION
INSULATION WHERE
SCHEDULED, NOM. THICKNESS
TO MATCH FRAMING DEPTH
METAL STUD RUNNER
4 1/4"
FLOOR STRUCTURE
BASE B3
GWB BOTH SIDES AS SCHEDULED
METAL STUDS AS
SCHEDULED
SOUND ATTENUATION
INSULATION WHERE SCHEDULED,
NOM. THICKNESS TO MATCH
FRAMING DEPTH
METAL STUD RUNNER
ACOUSTIC JOINT BOTH SIDES
FLOOR STRUCTURE
VARIES, REFER TO SCHEDULE
4 7/8"
ZZ
7"
EQ.
EQ.
5/8" GWB on metal stud framing, hold tight to steel. Finished GWB at column face to align with perimeter GWB soffit above, typ.
all perimeter columns.
Existing exterior claddingExisting spray on thermal insulation
5/8" GWB on 3 5/8" metal stud framing.
V .I.F
1'-6" +/-
Existing aluminum window system
Edge of concrete slab
SSM-1 sill
Interior partition may occur, see overall plan
Edge of concrete slab
5/8" GWB on 3 5/8" metal stud framing.
V aries
Existing curtainwall framing
1'-10 1/2" +/-
Equal, unless indicated on overall plan
This dimension dependant on consistant ability to hold GWB to face of steel (with fireproofing), all perimeter columns, typ.
Should be minimum 1'-8"
M in.
Line of GWB soffit above
Electrical outlet may occur.
See Electrical drawings.
5/8" GWB on 2 1/2" metal stud framing.
Level 13 220'-5 5/8"
Level 14 239'-1 5/8"
7"
1/2"
Scheduled finish flooring material to extend onto and conceal steel plate.
Provide feathered out leveling compound as req. for smooth transition.
Raised access flooring may occur
Scheduled base
5/8" GWB on 3 5/8" metal stud framing
Brace metal framing to steel curtainwall framing
SSM-1 sill on wood blocking. Sit 1" below line of existing window frame.
Overhang 1/2" at GWB below
Clear silicone sealant
Face of GWB at column end beyond
Face of GWB between windows
Perimeter soffit @ 13'-8"H Typ.
5/8" GWB on metal framing
Scheduled ACT
Linear diffuser, see mechanical drawings
Aluminum window system
Existing spray on thermal insulation
Existing curtainwall framing
Repair safing where dislodged
Existing exterior cladding system
ZZ
1"
1/
2"
Continuous steel plate, 10" wide x 1/4" thick, to follow curve along exterior wall.
3/16" dia. (5mm) HILTI KWIK-CON II (or eq.) anchors @ 18" O.C with 1 3/4" (44mm) embedment.
Anchor to be min. 2" from edge of concrete slab.
10"
Existing concrete slab
Scribe GWB edge to existing building window frame. Finish with clear sealant.
1'-10 1/2"
Window treatment by Owner
R E G
I STERED ARCH
I T E C T
WILLIAM
C.
AYARS
ST
AT
E OF OHIO
William C. Ayars, License #7259 Expiration Date 12/31/2015
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Carl B. Stokes US Court House
801 West Superior Avenue
A0-01
DAS
Partition Types
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
PARTITION SCHEDULE - NON-STRUCTURAL METAL FRAMING GROUPS A - L
TYPE
CONSTRUCTION DATA
TOP
TERMINATION
NOTESOV
ER
AL
L P
AR
TI
TI
ON
D
EP
TH
GW
B
TH
IC
KN
ES
S
FR
AM
IN
G
SI
ZE
DE
TA
IL
AT
T
OP
DE
TA
IL
AT
B
AS
E
ST
UD
S
TO
S
TR
UC
TU
RE
GW
B
TO
S
TR
UC
TU
RE
IN
SU
LA
TI
ON
T
O
ST
RU
CT
UR
E
Group A - Material, Furring, Substrate A03 2 1/8" 5/8" 1 1/2" T1 B1 - - - A07 3 1/8" 5/8" 2 1/2" T1 B1 - - - Group B - Material, Stud B03 3 1/8" 5/8" 2 1/2" T2 B2 ● - - B05 4 1/4" 5/8" 3 5/8" T2 B2 ● - - B06 4 1/4" 5/8" 3 5/8" T2 B2 ● - ● Group C - Material, Stud, Material C01 4 7/8" 5/8" 3 5/8" T3 B3 ● - - C02 4 7/8" 5/8" 3 5/8" T3 B3 ● ● ● Typ. Partition, U.N.O. See plans.
C11 7 1/4" 5/8" 6" T3 B3 - - -
General Partition Notes:
1. Not all partition groups or types within groups have been utilized - resulting type numbers may not be sequential. Refer to partition schedules for types utilized in this project.
2. For all partition systems that are indicated to extend from floor slab to underside of structure or floor slab above, including all Fire Rated partitions and all partitions indicated to have a Sound Transmission Class (STC), provide assembly at head of partition that will accommodate a minimum deflection of the structure above the partition, but not less than L/360 (where L= the span of the structure) without transferring loads resultant from that deflection to the partition assembly.
3. Provide assembly that will transfer lateral loads applied normal to the face of the partition system into the structure or floor slab above. Where Fire-Rated partitions occur , provide a UL-listed and approved head assembly for that partition that has been tested and determined to provide a Fire Rating equivalent to that of the Fire Rated Partition. Where partitions indicated to have a Sound Transmission Class occurs, provide a head assembly for that partition that has been tested and determined to provide a Sound Transmission Class equivalent to that of the Sound Rated Partition. All head assemblies shall be installed in strict conformance to manufacturers recommendations.
4. All GWB to be type "X" U.N.O.
5. Provide tile backer boards on all walls scheduled to receive wall tile.
6. Provide moisture resistant GWB at all plumbing fixtures, moisture resistant GWB to extend minimum 24" beyond edge of plumbing fixture.
7. All penetrations in rated partitions to be firestopped. See Life Safety Plan for locations of fire and smoke rated partitions.
8. Contractor to patch and repair any existing sprayed-on steel fireproofing that may be disturbed by new construction. See specification 078100.
Comply with requirements indicated on drawing LS-01.
9. All assemblies with sound attenuation insulation are considered acoustical partitions. Provide acoustical sealant at all penetrations. See typical Acoustical Penetration Detail, located sheet A0-00
NOTE: REFER TO FLOOR PLAN DRAWINGS FOR SPECIFIC PARTITION TYPE LOCATIONS
Scale
16" 32" 64"
3/4" = 1'-0"
Exterior Wall Plan Section at Column, Typ.
D20
Scale
16" 32" 64"
3/4" = 1'-0"
Exterior Wall Section, Typ.
D1
DEMOLITION PLAN LEGEND
Existing construction to remain
Construction to be demolished
# Number represents coded demolition note
E F G H
J
K
L
G.1
ZZ
YY
H.5
WW
XX
WW.3
AA
BB
CC
DD
EE
FF
GG
HH
JJ
LL
KK
P R
O
JE
C T
LIM
IT
PROJE
CT L
IM
IT
Contractor access w/ temporary door
M
in. 3'-8"
PROJECT LIMIT
Temporary partitio n
DEMOLITION PLAN CODED NOTES
1 Remove interior partition from floor to underside of structure above. Prepare all adjacent surfaces to receive new construction and scheduled finish. Existing walls shown to be removed shall be demolished complete. This includes the removal of reinforcement, soffits, doors, windows, frames and overhead bracing. COORD with MECH and ELEC for disconnection and removal of EXIST utilities and devices located within areas scheduled to be demolished.
2 Temporary partition and emergency door to be located inside of new partition location. Door intended for emergency egress only as to not interfere with other building tenants operations. NOTE: Contractor may opt to build permanant wall structure (w/ door) in planned final location in lieu of temporary. Provide sheathing only Corridor side with GWB until construction phase.
3 Remove existing door, frame, anchors, thresholds, and hardware as indicated within limits of construction. Patch and repair wall and floor to match existing.
Owner shall have the right to salvage any and all doors and hardware.
Contractor shall verify doors for salvage or relocation prior to commencing demolition.
4 Remove existing plumbing chase. Refer to engineering drawings for relocation of plumbling.
5 Contractor to maintain building access between elevator and adjacent tenant.
TEMPORARY PARTITIONS NOTES
1. Contractor shall at all times provide and/or maintain separation between Owner occupied areas and areas under construction or partially constructed.
2. Contractor shall construct and maintain at all times temporary partitions. Temporary partitions shall be located to separate Owner occupied areas from construction areas.
Temporary partitions shall not interfere with Owner's operation of facility.
3. Temporary partitions are to be constructed prior to any demolition work.
4. Additional or modifications to the temporary partitions may be required due to sequencing of work. Contractor to determine location and quantity of all temporary partitions prior to submittal of bid. Removal of temporary partitions to coincide with completion of enclosed space. U.N.O.
5. After removal of temporary partitions, the contractor shall restore all adjacent finishes disturbed by temporary partitions to their condition prior to erection of the temporary partitions.
6 Remove existing flooring and wall base. Prepare existing surface to receive new scheduled finishes.
FUTURE
TENANT PROJECT
SCOPE
ELEVATORS
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
R E G
I STERED ARCH
I T E C T
WILLIAM
C.
AYARS
ST
AT
E OF OHIO
William C. Ayars, License #7259 Expiration Date 12/31/2015
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Carl B. Stokes US Court House
801 West Superior Avenue
A1-01
Author
Partial 13th Floor Demolition Plan
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
GENERAL DEMOLITION NOTES
A Refer to specifications section 017320 - Selective Demolition for additional requirements and information.
B Project Limit line is indicated for general intent only. Additional demolition will be REQ'D outside of this line. Architectural demolition drawings are for schematic purposes. Contractor shall COORD all demolition with the entire set of contract documents for full scope of demolition work REQ'D for the project.
C EXIST conditions shown on these drawings are not guaranteed to be complete. The contractor shall verify all EXIST conditions, dimensions, and materials REQ'D for the contracted work. Report all discrepencies to architect prior to fabrication, erection, and/or installation.
D COORD all new penetrations and/or openings with other associated trades.
E The Owner may select and tag items for demolition to be salvaged. The contractor shall remove selected items from the scope of work and deliver to the Owner's requested location within the EXIST facility.
F Contractor shall provide HEPA filtered negative air machine(s) to maintain negative pressure to scope of work area ensuring no dust will be transfered to occupied areas. Provide visual pressure monitoring device at dust proof barricade to confirm pressure.
G The Facility's EXIST smoke and fire suppression system shall remain in operation during the entire construction phase.
H All demolition work being done outside of temporary partitions is to be appropriately sealed off to prevent the transmission of dust and debris and minimize disruption to visitors, residents, and staff. COORD location of barriers with Owner.
J Provide dust removing walk off mat (tacky mat) at constrution entry points.
K Some items may be indicated in the demolition drawings and demolition notes which are not necessarily demolition work but are included to describe the overall scope of the project and to aid in the demolition COORD. The contractor is responsible for all work required to complete the intended work of the overall project.
L Remove existing floor finishes, grouts, mastics, and setting beds complete to EXIST CONC floor slab or other substrate ready for new floor finishes. Floor preparation shall be by the installing contractor.
M Remove existing light fixtures within limits of demolition. COORD with Owner any items to be salvaged.
N Debris removal shall not interfere with facilities operations. Coordinate with Owner.
O Plug abandoned floor openings with new CONC. Plug shall match EXIST slab depth and be structurally sound to carry floor load of 100 LBS/ SQ FT unless noted otherwise.
P All fire rated assemblies (columns, shafts, walls, etc.) shall be maintained/patched. Match EXIST fire rating unless noted otherwise.
Q See mechanical and electrical drawings for additional demolition work.
R Remove partitions indicated to the underside of the structure above.
S All noise generating operations which interfere with a tenant's "quiet enjoyment" of their space are to occur after hours. Coordinate with Owner.
Scale
4' 8' 16'
1/8" = 1'-0"
Partial 13th Floor Demolition Plan
N O
R T
H
WALL LEGEND
Existing construction to remain
New construction
# Partition Type, Refer to A0-01
MIC Office 13-12
WCM
Office 13-13
SOO Office 13-14
ESA Office 13-15
Elec./ Tech.
13-16A
RMS Office 13-17
Equip.
13-07
Elec.
13-08
Multipurpose Rm.
13-02
Future Tenant 1300X
Training 13-09
Collaboration Area 13-11
Ready Rm 13-06
Copy/ Stor.
13-03
Reception 13-01
S torage &
Lg. Lockers
Conference Rm.
13-05
A2-02
A4-02 B3
Vest.
13-00
E F G H
J
K
G.1
ZZ
YY
H.5
3.5
WW XXWW.3
AA
BB
CC
DD
EE
FF
GG
HH
JJ
LL
KK
Hall 13-10
Bldg. Corr 13-18
Storage 13-19
07B 18
07A
00C
P R
O
JE
C T
LIM
IT
PROJE
CT L
IM
IT
PROJECT LIMIT
Elec./ Tech.
13-16B
Typ. @ all exterior windows this room
Typ. @ all exterior windows this room
Diagonal hatch indicates intended scope of access flooring (ASF-1) under scheduled carpet
A4-02 C2
00B
00A
05A
05B
Hall 13-04
16B
16A
3 10'-3 1/2" 5'-9"
B05
8a
DN
A3-03
D2
E4 A2-01
E3 A2-01
F E
C
A03
A03
D2 A0-01
1'-2 1/2"
B05 B05 B05
B05 B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05
B05 Typ. @ perimeter column conditions
FEC
F E
C
FEC
FEC
FEC
A0-01
D1
90°98
3'-0"
20'-0"
20'-0" 20'-0"
20'-0"
5'-7"
2'-4" +/-
8'-5 1/2" +/-
1'-2 1/2"
1'-2 3/4"
M
in. 5'-0"
WORKLINE #1
WORKLINE #1
WORKLINE #2
WORKLINE #2
WORKLINE #1
WORKLINE #2
WORKLINE #3
WORKLINE #4
WORKLINE #5
WORKLINE #3
WORKLINE #4
WORKLINE #5
WORKLINE #3
WORKLINE #4
WORKLINE #5
P
LA
N R
E F
E R
E N
C E
LIN
E
- A
P
LA
N R
E F
E R
E N
C E
LIN
E
- A
P
LA
N R
E F
E R
E N
C E
LIN
E
- A
P
LA
N R
E F
E R
E N
C E
LIN
E
- B
18'-0"
WORKLINE #3
WORKLINE #2
18'-0"
8b
18'-9"
18'-9"
8b
16'-1"
8b
P
LA
N R
E F
E R
E N
C E
LIN
E
- B
WORKLINE #1A at C
OLUMN LINE YY
1. All dimensions are to finish face of wall unless noted/shown otherwise.
Angular dimensions shown for general design intent reference only.
Questions or discrepiencies shall be directed to Architect.
2. Refer to Life Safety Plans for rated wall locations.
3. Dashed furniture and equipment items shown for reference only and is not part of the General Contract. These items will be provided and installed by Owner. Contractor may need to coordinate specific fixture and equipment requirements if noted.
4. Contractor to verify all dimensions and conditions in the field prior to commencement of work. If drawings conflict with actual field conditions, contact Architect before proceeding with work.
5. All partitions to be Type ‘C02’ unless noted otherwise. Refer to all floor plan drawings for specific partition type locations. See A0-01 for partition types.
6. Provide concealed in-wall reinforcing/blocking for secure attachment of all millwork, casework, and/or accessories as required.
7. Refer to elevations for dimensions and locations of glass storefront windows and partitions.
8. Contractor to provide $2500.00 project allowance for signage material.
Units to be to be coordinated and selected by Owner, installed by contractor.
Base bid shall include labor for installation.
FLOOR PLAN GENERAL NOTES
1 Raised access flooring (ASF-1) to be provided this area. Manufacturer to provide shop drawings and further coordination, see spec. section 09 69 33.
2 Provide glass film at windows located this area. (GF-3) See specification section 088000
3 Align new partition with edge of existing window.
4 New partition to align and extend straight from existing wall condition.
5 Access panel source location for cable tray feed from Equip. Rm to Ops.
Stations through steel cable tray as indicated on RCP. See details sheet A5-02.
See elevation sheet A402 for height and location information.
6 New pipe chase. Hold tight as possible to relocated utilities
7 Conceal existing elevator door opening, call button, and hall lantern in new type A03 partition to min. 6" above top of elevator door opening. Do not attach new partition to existing door framing, call button or hall lantern.
8a Maintain 5'-3"W hallway extending from outside suite and following curve of building exterior. All offices should be approx. same depth dimension.
9 Intent to hold GWB enclosure tight to steel structure. Refer to elevations for angled conditions in Recept. and Collaboration Area.
10 Ramp at entry into Ops. Stations to be 1:20 slope, starting at door threshold. All trim units to be provided and coordinated by access flooring manufacturer as necessary to comply with ADA guidelines. Shop drawings to be reviewed by Architect prior to installation.
11 Segmented glass storefront system intended to follow radius of Hall. GWB dividing walls @ offices to extend approx. 4 1/2" from face of glass, see E6/A2-01. Provide GWB corner reinforcement @ all outside corners of projected dividing walls between offices. (Certainteed Aquabead, or eq. )
12 Contractor to maintain access for building occupants between elevator and adjacent tenent. Work this area to occur after hours.
FLOOR PLAN CODED NOTES -
Coded Notes combined for A2-01 and A2-02, some not used this sheet
13 See section D1/A5-02 for access to conduit tray cavity at Equip. Rm side.
14 Built out GWB wall portion to accomodate recessed fire extinguisher cabinet.
15 Provide bracket mounted fire extinguisher
16 Patch and repair existing concrete floor as required to receive scheduled flooring.
17 All existing exposed studs this area to receive 5/8" GWB sheathing, full height.
Workline references. Provided for consistant 90 degree reference points.
X '-X
Workline and Plan Reference line locator dimensions shown underlined
PLAN DIMENSIONS
8b Design intent is for radiused wall at corridor to be continuously inset 18'-9" from existing exterior wall.
18 See RCP for angle this area. Intent to align wall with ceiling plane
FUTURE
TENANT PROJECT
SCOPE
ELEVATORS
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
ZZ
H.5
Existing building perimeter wall
Existing window
Existing window
EQ
EQ
B05 B05
New sill condition
New sill condition
B05
B05
C02
YY
H.5 FF
A03
A03
1'-8" +/-
A03
FEC
C02
1'-2 3/4"
7 7/8" +
Hold GWB tight as possible to steel these faces
YY
CC
A07
B05
A03 Hold GWB tight as possible to steel this face
See RCP for angle this area
1'-8"
WORKLINE #1
elevation V aries, see
G.1
YY
11 Typ.
WORKLINE #1
5'-0"
P
LA
N R
E F
E R
E N
C E
LIN
E
- B
Squared millwork build out for proper operation of interior drawers
Hardwood edge condition, WD-2
Fryreglet (or eq.)
1/2" metal "F" reveal
1 1/2"
5 1/2" 2'-10 1/8"
R adiused w all. Inset
18'- 9" from existing exterior surface.
3"
4 1/2"
WORKLINE #1A at COLUMN LINE YY
Typical inset of office divider walls of column line YY
R E G
I STERED ARCH
I T E C T
WILLIAM
C.
AYARS
ST
AT
E OF OHIO
William C. Ayars, License #7259 Expiration Date 12/31/2015
SHEET OF
DISCIPLINE
DRAWING NO.
DRAWN BY
DATE
PCN NO.
GSA PM
PROJ. DESC.
BLDG NO.
CITY/ST./ZIP
STREET
BLDG NAME
MARK
FLOOR NO.
DATE
DESCRIPTION
REVISION
TITLE
GENERAL SERVICES ADMINISTRATION
SHEET DESIGNATOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice
Properly destroy or return documents when no longer needed
SHEET SIZE
SUB A/E
PRIME A/E
CONS. CONTR.
A/E CON. NO.
C O
N T
R A
C T
O R
S
CONSTR. CON.
A/E TASK NO.
CONS. WORK
CONTRACTOR INFO
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Carl B. Stokes US Court House
801 West Superior Avenue
A2-01
Author
Partial 13th Flr. Plan
Cleveland
11/18/2015Final Design Submittal
GS-05P-11-SLD-0057
5PSCE-15-0038a
1503A
Fredrick, Fredrick & Heller Engineers
230 South Dearborn St Chicago, Illinois 60604
OH 44113
NOAA Office Renovation
John Bolovan 24x36
11/18/2015
13 ROH00736
OH0301ZZ
Perspectus Architecture
Scale
4' 8' 16'
1/8" = 1'-0"
Partial 13th Floor Plan 1 N
O R
T H
Scale
16" 32" 64"
1/2" = 1'-0"
Plan Detail 1 E3
Scale
16" 32" 64"
1/2" = 1'-0"
Plan Detail 2 E4
Scale
16" 32" 64"
1/2" = 1'-0"
Plan Detail 3 E5
Scale
16" 32" 64"
1/2" = 1'-0"
Plan Detail 4 E6
Flat portion over Conf. Rm. @ 11'-2"
5/8" GWB on standard metal framing. Contractor to provide kickers and support to building steel as required for stability.
Contractor may propose suspending GWB from cable and runner connections provided that stability is not compromised.
All GWB visible from below to be painted PT-2, typ.
Angle dimensions are approximate. See Conference Rm- North elevation, sheet A4-01 for reference start point of continuous slope.
Line of SC-1 @ 13'-8"
Angle dimensions are approximate. See conference room elevations for continuous slope determined by structure.
Inset wood perimeter trim to hold MSC-1. Continued at all perimeter edges of SC-1 where SC-1 drops below GWB.
1'-6"
Angled finished GWB to extend min 18" past edge of SC-1
Perforated metal screening (MSC-1) at perimeter edge of SC-1 to conceal visible gap wherever SC-1 drops below GWB mass.
155.00°
1/
2"
Perforated metal screening (MSC-1) at perimeter edge of SC-1 to conceal visible gap wherever SC-1 drops below GWB mass.
Inset wood perimeter trim to hold MSC-1. Continued at all edges of SC-1 where SC-1 drops below GWB.
Line of SC-1, @ 13'-8"
Steel bracing @ Max. 8'-0" O.C., typ.
MSC-1 side profile
MSC-1 screening in front of GWB mass, wherever SC-1 drops below GWB.
Acoustical batting
Line of SC-1 in front of GWB mass
10"
Extend MSC-1 10" (min.) past junction where GWB drops below SC-1
10"
Extend MSC-1 10" (min.) past junction where GWB drops below SC-1
1'-6"
Angled finished GWB to extend min 18" past edge of SC-1
Line of SC-1 in front of GWB mass
D1 A3-03
Open to Hall
GWB 13'-9"
Curved GWB soffit above storefront system.
5/8" GWB on standard metal framing or suspended onto main runners. Contractor to provide kickers and support to building steel @ 8'-0" O.C. (max.)
Angle aligned w/ wall start, and determined by slope of GWB soffit above wood lockers. See elevations.
1/
2"
Scheduled ACT ceilingSee RCP
1'-5"
Wood paneling above wood lockers
Segmented storefront system at Offices
YY
3"
Line of GWB office divider partition
A lig n
W O
R K
LI
N
E
1A at
C O
LU
M
N Y
Y
"Lightning Bolt" steel cable tray feature.
See addtl. details on sheet A3-02.
Hanger support straps at knuckle
Intermediate support
D4
A3-03
SC-1
GWB ceiling massGWB soffit above lockers
7' -1
0"Wood lockers
Ready Rm. bar counter
C4
A3-03
Termination into soffit above Ready Rm cabinets
M in
. 8
9' -0
98° +/-
Intermediate support
Painted steel cable tray.
Steel gauge: 11 (Min.)
Steel substrate to be smooth, suitable for primed and painted finish Paint: PT-4, gloss finish
Width varies, refer to RCP
D3 A3-03
Continuous reinforcement edge bracket with exposed steel fasteners.
1/
4"
Exposed steel fasteners to be painted PT-5, located min. (1) per every 16" of length.
All steel edges to be smooth, deburred. All welded corners/edges to be smooth, consistant appearance, typ.
Continuous reinforcement edge bracket with exposed steel fasteners.
See detail C4 this sheet for hanger support
1' -0
4"
Inset .89"W x .36"D continuous LED strip light, run full length of steel. Contractor to assure steel substrate is prepared and suitable for adhesion provided by light manufactuer. Coordinate w/ electrical plans.
1/
8"
7/8"
Steel fasteners to be painted PT-5, located min. (1) per every 16" of length.
Continuous reinforcement edge bracket/ channel with exposed steel fasteners.
7/8"
1/
4"
3/ 8"
3.5"W Stainless steel hangar support strap forms continuous loop around cable tray and attaches to scheduled ceiling with exposed, stainless steel bolt fasteners and washers.
Steel gauge: 11 (Min.)
No. 4 finish All corners welded with smooth even appearance
Provide 3" x 3" x 1/4" steel angle braced to structure above, concealed above ceiling as required for suspension of "Lightning Bolt" cable tray
Stainless steel hangar support strap continued from ceiling loop, fully around cable tray. Attach with exposed, unpainted bolt fasteners. See elevation this sheet for height, see also RCP.
Provide steel fillers beneath support strap as required to acheve stable, flush condition.
Continuous LED strip
Custom cable tray, see detail D4 this sheet to D
2/ A
3-
V ar ie s, R ef er
Continuous reinforcement edge bracket
Varies, see RCP
1 1/2" 1 1/2"Eq. spacing - 6" Max
See additional details this sheet
Small tray extends and overlaps into larger tray. See width dimensions on RCP.
Line of sloped GWB soffit above lockers
Stainless steel continuous hanger strap support w/ exposed, unpainted bolt fasteners.
Painted steel cable tray
Channel for inset continuous LED strip
Align
1'-9"
1'-11"
3 1/2"
7" 7"
Face of existing building exterior
GWB pocket and vertical transition at window perimeter, see RCP.
Acoustical ceiling manuf's "F" vertical transition moulding
Scheduled ACT ceiling lower than GWB soffit, see RCP.
Metal framing as required
Face of GWB at column end beyond
Perimeter soffit @ 13'-8"H Typ.
5/8" GWB on metal framing
Linear diffuser, see mechanical drawings
Scribe GWB edge to existing building window frame. Finish with clear sealant.
1'-10 1/2"
Face of existing building exterior
SC-1, See RCP for height. Hold offset continuous 1 1/2", all edges of SC-1 to be finished. All runners and hanging devices to be held back min. 1", sheilded from view below.
Black acoustical material between runners
1 1/2"
1"
1/
2"
Edge of of GWB partition at MIC Office
Dropped GWB soffit above storefront system
Storefront metal framing
A lig n
Start of GWB ceiling at Hall
1"
Line of SC-1 @ 13'-8"
Inset wood perimeter trim to hold MSC-1, finish exposed faces to match SC-1.
Acoustical batting
Profile of MSC-1 wrapped and attached to wood perimeter trim with concealed fasteners.
This edge detail to continue at perimeter edges of SC-1 where SC-1 drops below GWB, to screen HVAC and suspension framing/wires from view below.
1 1/4"5/8"
1/
2"
Hold consistant offset from GWB mass above.
FUTURE
TENANT PROJECT
SCOPE
ELEVATORS
N O
R T
H
Building Key Plan - Stokes 13th Floor not to scale
2'-0"
1'-1"
1'-8"
7" 7"
3 1/2"
Stainless steel continuous hanger strap w/ exposed unpainted bolt fasteners
Painted steel cable tray
Wall between Ops Stations and Collaboration Area
See section detail A5-02
R E G
I STERED ARCH
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .