Federal_Building_US_Courthouse_Ft_Myers_FL0009ZZ.xls
XLS spreadsheet 133 KB Posted
- Solicitation number
- GS-04P-14-EW-D-0135
About this file
Equipment List Ft. Myers
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Revised_Solicitation_GS_04P_14_EW_D_0135__29MAY2015.pdf | ||
| GS-04P-14-EW-D-0135_SF30_AMENDMENT_006__29MAY.pdf | ||
| SOLICITATION_GS04P14EWD0135__AMENDMENT_005__15MAY2015.pdf | ||
| Amendment_004.pdf | ||
| Amendment_003.pdf | ||
| Attachment_1_-_Amendment_002.pdf | ||
| Amendment_002.pdf | ||
| Amendment_001.pdf | ||
| Preventive_Maintenance_Schedule.doc | DOC document | |
| Timberlake_Jr_Federal_Building_Tampa_FL0064AE.xls | XLS spreadsheet | |
| George_C_Young_Orlando_FL0082ZZ.xls | XLS spreadsheet | |
| Timberlake_Federal_Building_Annex__Tampa_FL0002AE.xls | XLS spreadsheet | |
| Golden_Collum_Federal_Building_Ocala_FL0057ZZ.xls | XLS spreadsheet | |
| Sam_M_Gibbons_U_S_Courthouse_Tampa_FL0012ZZ.xlsx | XLSX spreadsheet | |
| U_S_Courthouse_Orlando_FL0025ZZ.xls | XLS spreadsheet | |
| Charles_E_Bennett_Federal_Building_Jacksonville_FL0067ZZ.xls | XLS spreadsheet | |
| O M_Site_Visit_Schedule_(5).pdf | ||
| Bryan_Simpson_US_Courthouse_Jacksonville_FL0017ZZ.xls | XLS spreadsheet | |
| GS-04P-14-EW-D-0135_12-30-2014_(1).pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Equipment - Equipment List by B
| Equipment List by Building and Equipment ID - Detail | ||||||||||||||
| Total Record Counts: | 120 | |||||||||||||
| FL0009ZZ | ||||||||||||||
| Building: | ||||||||||||||
| Equipment ID | Equipment Description | Equipment Type | Floor | Room | Location | Manufacturer | Model No. | Serial No. | ||||||
| FL0009ZZ-000000035 | Condenser, Air-Cooled | ACC | Ground Floor Parking Lot Next to Sally Port Door | Liebert | DMC-027 | |||||||||
| FL0009ZZ-000000036 | Condenser, Air-Cooled | ACC | Roof Roof / Roof Installed Item Units are numbered | Liebert | DMC-02A | |||||||||
| FL0009ZZ-000000037 | Condenser, Air-Cooled | ACC | Roof Roof / Roof Installed Item Units are numbered | Liebert | DMC-02A | |||||||||
| FL0009ZZ-000000038 | Condenser, Air-Cooled | ACC | Roof Roof / Roof Installed Item Units are numbered | Liebert | PFC-020A | D043393 | ||||||||
| FL0009ZZ-000000039 | Condenser, Air-Cooled | ACC | Roof Roof / Roof Installed Item Units are numbered | Liebert | PFC-020A | |||||||||
| FL0009ZZ-000000040 | Condenser, Air-Cooled | ACC | Roof Roof / Roof Installed Item Units are numbered | Liebert | PFC-020A | |||||||||
| FL0009ZZ-000000073 | Air Conditioner Package | ACU | Penthouse Elevator / Mechanical Penthouse Access is outside on rooftop | 42WA-B | ||||||||||
| FL0009ZZ-000000074 | Air Conditioner Package | ACU | Penthouse Elevator / Mechanical Penthouse Access is outside on rooftop | 49WA-B | ||||||||||
| FL0009ZZ-000000001 | AIR HANDLING UNIT | AHU-01 | 01 | 1-130 | Floor 01 Mechanical Equipment Room Room # 1-130 | TRANE | MCCA014BBG0CAEA00000000 | K97A12050 | ||||||
| FL0009ZZ-000000002 | AIR HANDLING UNIT | AHU-01 | 01 | 1-130 | Floor 01 Mechanical Equipment Room Room # 1-130 | TRANE | MCCA008GAN0ABC000D0ECA00CAA000BA00C00F300A0 | K97A03293 | ||||||
| FL0009ZZ-000000003 | AIR HANDLING UNIT | AHU-01 | 02 | 2-130 | Floor 02 Mechanical Equipment Room Room # 2-130 | TRANE | MCCA035GAN0ABC000J0ECA00CAA0000AD000C00FB00A0 | K97A05911 | ||||||
| FL0009ZZ-000000004 | AIR HANDLING UNIT | AHU-01 | 02 | 2-130 | Floor 02 Mechanical Equipment Room Room # 2-130 | TRANE | MCCA021GANDABC000G0ECA00CAA0000BC000C00FB00A0 | K97A11696 | ||||||
| FL0009ZZ-000000005 | AIR HANDLING UNIT | AHU-01 | 03 | 3-129 | Floor 03 Mechanical Equipment Room Room # 3-129 | TRANE | MCCA021GAN0ABC000H0ECA00CAA0000BC000C00FB00A0 | K97A11738 | ||||||
| FL0009ZZ-000000006 | AIR HANDLING UNIT | AHU-01 | 03 | 3-129 | Floor 03 Mechanical Equipment Room Room # 3-129 | TRANE | MCCA017GAN0ABC000G00ECA00CAA0000AC000C00FB00A0 | K97A11754 | ||||||
| FL0009ZZ-000000007 | AIR HANDLING UNIT | AHU-01 | 04 | 4-140 | Floor 04 Mechanical Equipment Room Room # 4-140 | TRANE | MCCA031GAN0ABC000H0ECA00CAA0000BC000C00FB00A0 | K97A11747 | ||||||
| FL0009ZZ-000000008 | AIR HANDLING UNIT | AHU-01 | 04 | 4-140 | Floor 04 Mechanical Equipment Room Room # 4-140 | TRANE | MCCA021GAN0ABC000G0ECA00CAA0000AC000C00FB00A0 | K97A11645 | ||||||
| FL0009ZZ-000000009 | AIR HANDLING UNIT | AHU-01 | 05 | 5-151 | Floor 05 Mechanical Equipment Room Room # 5-151 | TRANE | MCCA021GAN0ABC000H0ECA00CAA0000BC000C00FB00A0 | K97A12059 | ||||||
| FL0009ZZ-000000010 | AIR HANDLING UNIT | AHU-01 | 05 | 5-151 | Floor 05 Mechanical Equipment Room Room # 5-151 | TRANE | MCCA021GAN0ABC000G0ECA00CAA0000AC000C00FB00A0 | K97A12153 | ||||||
| FL0009ZZ-000000011 | AIR HANDLING UNIT | AHU-01 | 06 | 6-148 | Floor 06 Mechanical Equipment Room Room # 6-148 | TRANE | MCCA025GAN0AB000H0ECA00CAA0000BC000C00FB00A0 | K97A12099 | ||||||
| FL0009ZZ-000000012 | AIR HANDLING UNIT | AHU-01 | 06 | 6-148 | Floor 06 Mechanical Equipment Room Room # 6-148 | TRANE | MCCA021GAN0ABC000H0ECA00CAA0000AC000C00FB00A0 | K97A12166 | ||||||
| FL0009ZZ-000000015 | AIR HANDLING UNIT | AHU-01 | CH | Penthouse Chiller Mechanical Room Outside Air Unit | TRANE | MCCA066GAPOAP00BAL0ECA00CAA0000ADA00D00AA00A0 | K97K16732A | |||||||
| FL0009ZZ-000000029 | Air Handling Unit, Computer Room | AHU-04 | PR | Ground Floor General Building South PBX Telephone Room | Liebert | MME-024A | 94245 | |||||||
| FL0009ZZ-000000030 | Air Handling Unit, Computer Room | AHU-04 | 04 | 4-110 | Floor 04 Warehouse / Storage Room 4-110 | Liebert | MME-018E | 94243 | ||||||
| FL0009ZZ-000000031 | Air Handling Unit, Computer Room | AHU-04 | 04 | 4-150 | Floor 04 General Building Room 4-150 | Liebert | MME-018E | 94244 | ||||||
| FL0009ZZ-000000032 | Air Handling Unit, Computer Room | AHU-04 | 03 | 3-112 | Floor 03 General Building Room 3-112 | Liebert | MME-018E | 99279 | ||||||
| FL0009ZZ-000000033 | Air Handling Unit, Computer Room | AHU-04 | 03 | 3-155 | Floor 03 Warehouse / Storage Room 3-155 | Liebert | MME-018E | 99278 | ||||||
| FL0009ZZ-000000034 | Air Handling Unit, Computer Room | AHU-04 | 05 | 5-158 | Floor 05 General Building Room 5-158 | Liebert | MME-018E | 103419 | ||||||
| FL0009ZZ-000000096 | Fire Detection and Alarm System | ALM | 01 | 1-114 | Floor 01 Control Center FACP 1st fl. North Room 1-114 | CERBERUS | MPS-RK | |||||||
| FL0009ZZ-000000097 | Fire Detection and Alarm System | ALM | 01 | 1-114 | Floor 01 Control Center FACP 1st fl. North Room 1-114 | CERBERUS | MPS-RK | |||||||
| FL0009ZZ-000000098 | Fire Detection and Alarm System | ALM | 01 | 1-114 | Floor 01 Control Center FACP 1st fl. North Room 1-114 | CERBERUS | MKB-3 | |||||||
| FL0009ZZ-000000099 | Fire Detection and Alarm System | ALM | Stairwells and Landings ON STANDPIPE RISER'S | Manufacturers | VSR-F | |||||||||
| FL0009ZZ-000000102 | Fire Detection and Alarm System | ALM | SW | Stairwells and Landings Also in Fire Pump Room | CERBERUS | |||||||||
| FL0009ZZ-000000105 | Fire Detection and Alarm System | ALM | CD | Throughout Entire Building Corridors/Elev. Lobby's/Suites etc. | CERBERUS | |||||||||
| FL0009ZZ-000000044 | Switch, Automatic Transfer | ATS | EG | Ground Floor Emergency Generator Room Next to Judges Garages | KOHLER | LR 58301 | K73912 | |||||||
| FL0009ZZ-000000050 | Building Automation System, DDC | BAS-01 | 1-135 | Ground Floor Office Room 1-135 | JOHNSON CONT | METASYS | ||||||||
| FL0009ZZ-000000090 | Backflow Prevention Device | BFP | NE | Ground Floor Outside Northeast corner of property | WATTS | 4060CE3 | N9353 | |||||||
| FL0009ZZ-000000091 | Backflow Prevention Device | BFP | NE | Ground Floor Outside Northeast corner of property | WATTS | Conb-4020A03 | NF138 | |||||||
| FL0009ZZ-000000092 | Backflow Prevention Device | BFP | CT | Roof Roof / Roof Installed Item Cooling Tower area on rooftop | WATTS | 975XL | 2883208 | |||||||
| FL0009ZZ-000000093 | Backflow Prevention Device | BFP | CH | Penthouse Chiller Mechanical Room Behind Chiller #1 | WATTS | 909QT | 613307 | |||||||
| FL0009ZZ-000000016 | Chiller, Centrifugal, water cooled, over 100 tons | CHL-CW2 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | TRANE | CHVE320 | L97B01160 | |||||||
| FL0009ZZ-000000017 | Chiller, Centrifugal, water cooled, over 100 tons | CHL-CW2 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | TRANE | CVHE320 | L97B01135 | |||||||
| FL0009ZZ-000000018 | Chiller, Centrifugal, water cooled, over 100 tons | CHL-CW2 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | McQUAY | WMC145SBS-ER10 | STNU110200107 | |||||||
| FL0009ZZ-000000019 | Cooling Tower | CTR | OT | Roof Outside Go Through Chiller Room to Roof | MARLEY | MC8405NAN1SGF | 10033931B1 | |||||||
| FL0009ZZ-000000020 | Cooling Tower | CTR | OT | Roof Outside Go Through Chiller Room to Roof | MARLEY | NC8405NAN1 | 10033931A1 | |||||||
| FL0009ZZ-000000041 | Davits/Roof Anchors/Fall Protection | DAV | Roof Roof / Roof Installed Item Throughout Roof Top | |||||||||||
| FL0009ZZ-000000103 | Fire Detection and Alarm System | ELT | CD | Throughout Entire Building Corridors/Elev. Lobby's/Suites etc. | CERBERUS | |||||||||
| FL0009ZZ-000000043 | Emergency Diesel Generator | EMG-01 | EG | Ground Floor Emergency Generator Room Next to Judges Garages | KOHLER | 450R0ZD71 | 385532 | |||||||
| FL0009ZZ-000000109 | Drinking Fountain, Packaged | EWC | 01 | CD | Floor 01 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724367 | ||||||
| FL0009ZZ-000000110 | Drinking Fountain, Packaged | EWC | 01 | CD | Floor 01 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724371 | ||||||
| FL0009ZZ-000000111 | Drinking Fountain, Packaged | EWC | 02 | CD | Floor 02 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724370 | ||||||
| FL0009ZZ-000000112 | Drinking Fountain, Packaged | EWC | 02 | CD | Floor 02 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724374 | ||||||
| FL0009ZZ-000000113 | Drinking Fountain, Packaged | EWC | 03 | CD | Floor 03 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724379 | ||||||
| FL0009ZZ-000000114 | Drinking Fountain, Packaged | EWC | 04 | CD | Floor 04 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724375 | ||||||
| FL0009ZZ-000000115 | Drinking Fountain, Packaged | EWC | 04 | CD | Floor 04 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724368 | ||||||
| FL0009ZZ-000000116 | Drinking Fountain, Packaged | EWC | 05 | CD | Floor 05 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724365 | ||||||
| FL0009ZZ-000000117 | Drinking Fountain, Packaged | EWC | 05 | CD | Floor 05 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724372 | ||||||
| FL0009ZZ-000000118 | Drinking Fountain, Packaged | EWC | 06 | CD | Floor 06 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724366 | ||||||
| FL0009ZZ-000000119 | Drinking Fountain, Packaged | EWC | 06 | CD | Floor 06 General Building CORRIDORS | HALSLEY TAYL | HAZ8FSQ-1B | 970724369 | ||||||
| FL0009ZZ-000000075 | Expansion Tank | EXT | Roof Outside Next to Cooling Towers | TACO | CA 140 | |||||||||
| FL0009ZZ-000000070 | Fan, Axial | FAN-01 | SW | Penthouse Stairwell #1 Rooftop | LORAN COOK | 24ED412D17U | ||||||||
| FL0009ZZ-000000071 | Fan, Axial | FAN-01 | SW | Penthouse Stairwell #2 Rooftop | LORAN COOK | 24ED412D17U | ||||||||
| FL0009ZZ-000000057 | Fan, Centrifugal | FAN-02 | NE | Roof Roof / Roof Installed Item Northeast Rooftop | LORAN COOK | 150ASPT | ||||||||
| FL0009ZZ-000000059 | Fan, Centrifugal | FAN-02 | NW | Roof Roof / Roof Installed Item Northwest Rooftop | LORAN COOK | 100ASPT | ||||||||
| FL0009ZZ-000000060 | Fan, Centrifugal | FAN-02 | SW | Roof Roof / Roof Installed Item Southwest Rooftop | LORAN COOK | 100ASPT | ||||||||
| FL0009ZZ-000000061 | Fan, Centrifugal | FAN-02 | CH | Roof Roof / Roof Installed Item In Chiller Mech. Room | LORAN COOK | 180C7B | ||||||||
| FL0009ZZ-000000062 | Fan, Centrifugal | FAN-02 | NW | Roof Roof / Roof Installed Item Northwest Rooftop | LORAN COOK | 135C3B | ||||||||
| FL0009ZZ-000000063 | Fan, Centrifugal | FAN-02 | NW | Roof Roof / Roof Installed Item Northwest Rooftop | LORAN COOK | 120C2B | ||||||||
| FL0009ZZ-000000064 | Fan, Centrifugal | FAN-02 | NW | Roof Roof / Roof Installed Item Northwest Rooftop | LORAN COOK | 330C11B | ||||||||
| FL0009ZZ-000000065 | Fan, Centrifugal | FAN-02 | SW | Roof Roof / Roof Installed Item Southwest Rooftop | LORAN COOK | 330C11B | ||||||||
| FL0009ZZ-000000066 | Fan, Centrifugal | FAN-02 | SW | Roof Roof / Roof Installed Item Southwest Rooftop | LORAN COOK | 100C2B | ||||||||
| FL0009ZZ-000000067 | Fan, Centrifugal | FAN-02 | SW | Roof Roof / Roof Installed Item Southwest Rooftop | LORAN COOK | 120C2B | ||||||||
| FL0009ZZ-000000013 | Fan Coil Unit | FCU | CH | Penthouse Chiller Mechanical Room Mounted on ceiling | TRANE | 10/CV | K97A05046 | |||||||
| FL0009ZZ-000000014 | Fan Coil Unit | FCU | CH | Penthouse Chiller Mechanical Room Mounted on ceiling | TRANE | 10/CV | K97A05031 | |||||||
| FL0009ZZ-000000051 | Fire Extinguishers | FEX | Throughout Entire Building | Manufacturers | Badger-B10M | |||||||||
| FL0009ZZ-000000046 | Fire Pump, Electric-Drive | FPM-01 | MC | Ground Floor Mechanical Equipment Room Southwest corner of Bldg. | ITTAC PUMP | 6X6X9F | 97-228565-01-01 | |||||||
| FL0009ZZ-000000107 | Fire and Smoke Dampers | FSD | Throughout Entire Building | |||||||||||
| FL0009ZZ-000000104 | Fire Detection and Alarm System | FSP-01 | CE | Throughout Entire Building Ceilings Throughout | ||||||||||
| FL0009ZZ-000000052 | Fire Hose / Hose Connections | HSE | Throughout Entire Building | Manufacturers | POWHATAN | |||||||||
| FL0009ZZ-000000083 | Motor Control Center | MCC | CH | Penthouse Chiller Mechanical Room Opposite Chiller #2 | GENERAL ELEC | Class 8000 SC/MC | ||||||||
| FL0009ZZ-000000084 | Motor Control Center | MCC | CH | Penthouse Chiller Mechanical Room Opposite Chiller #3 (Pony) | GENERAL ELEC | Class 8000 SC/MC | ||||||||
| FL0009ZZ-000000089 | Motor | MOT | Ground Floor Outside Parking Lot Area | RITE HITE | 45220 | |||||||||
| FL0009ZZ-000000053 | Motor, Fan | MOT-01 | EG | Ground Floor Emergency Generator Room Next to Judges Garages | LORAN COOK | 135SQIB | ||||||||
| FL0009ZZ-000000054 | Motor, Fan | MOT-01 | MC | Ground Floor Mechanical Equipment Room Fire Domestic Water Pump Rm. | LORAN COOK | 135SQIB | ||||||||
| FL0009ZZ-000000055 | Motor, Fan | MOT-01 | SP | Ground Floor Sally Port Southeast corner of Bldg. | LORAN COOK | 180SQIB | ||||||||
| FL0009ZZ-000000056 | Motor, Fan | MOT-01 | EE | Ground Floor Electrical Power Distribution Center (Primary Switchgear) | LORAN COOK | 165SQIB | ||||||||
| FL0009ZZ-000000058 | Motor, Fan | MOT-01 | EV | Roof Roof / Roof Installed Item Freight Elev. Shaft on Roof | LORAN COOK | 16A17DBS | ||||||||
| FL0009ZZ-000000068 | Motor, Fan | MOT-01 | JC | Ground Floor Parking Judge's Garage Covered Parking | LORAN COOK | 180SQIB | ||||||||
| FL0009ZZ-000000069 | Motor, Fan | MOT-01 | TR | Ground Floor General Building Trash/Recycling Room | LORAN COOK | 80SQD | ||||||||
| FL0009ZZ-000000072 | Motor, Fan | MOT-01 | 01 | 1-111 | Floor 01 General Building Fitness Ctr. Room 1-111 | LORAN COOK | GN820 | |||||||
| FL0009ZZ-000000045 | Motor, Pump | MOT-02 | MC | Ground Floor Mechanical Equipment Room Southwest corner of Bldg. | U.S. ELECTRI | FR - 364T5 | ||||||||
| FL0009ZZ-000000047 | Motor, Pump | MOT-02 | MC | Ground Floor Mechanical Equipment Room Southwest corner of Bldg. | BALDOR | 84-Z00011 | 35N156-0186C1 | |||||||
| FL0009ZZ-000000048 | Motor, Pump | MOT-02 | MC | Ground Floor Mechanical Equipment Room Southwest corner of Bldg. | GRUNDFOS | Ml132AB-2-213TC-C2 | 85900714 | |||||||
| FL0009ZZ-000000049 | Motor, Pump | MOT-02 | MC | Ground Floor Mechanical Equipment Room Southwest corner of Bldg. | BALDOR | SFA21-20/10 | 36H976-0194F5 | |||||||
| FL0009ZZ-000000085 | Powered Doors | PDR | EN | Ground Floor Parking Lot Parking Entry Door | Manufacturers | 80229 | ||||||||
| FL0009ZZ-000000086 | Powered Doors | PDR | PK | Ground Floor Parking Lot Parking Exit Door | Manufacturers | 80230 | ||||||||
| FL0009ZZ-000000087 | Powered Doors | PDR | SP | Ground Floor Parking Lot Sally Port Door | Manufacturers | 80238 | ||||||||
| FL0009ZZ-000000021 | Pump, Chilled Water | PMP-02 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 72928 | |||||||
| FL0009ZZ-000000022 | Pump, Chilled Water | PMP-02 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | MX4X10 4030 | 72930 | |||||||
| FL0009ZZ-000000023 | Pump, Chilled Water | PMP-02 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 72929 | |||||||
| FL0009ZZ-000000027 | Pump, Chilled Water | PMP-02 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 84170 | |||||||
| FL0009ZZ-000000028 | Pump, Chilled Water | PMP-02 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | Series4030-8x6x10 | ||||||||
| FL0009ZZ-000000024 | Pump, Condenser | PMP-06 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 73267 | |||||||
| FL0009ZZ-000000025 | Pump, Condenser | PMP-06 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 73268 | |||||||
| FL0009ZZ-000000026 | Pump, Condenser | PMP-06 | CH | Penthouse Chiller Mechanical Room Take Freight Elevator to Fl. #7 | Armstrong | 5X4X10 4030 | 73269 | |||||||
| FL0009ZZ-000000042 | Roof System and Drains | RFS | Roof Roof / Roof Installed Item Throughout Roof Top | |||||||||||
| FL0009ZZ-000000100 | Fire Detection and Alarm System | SDS | CD | Throughout Entire Building Corridors/Elev. Lobby's/Suites etc. | CERBERUS | ION | ||||||||
| FL0009ZZ-000000101 | Fire Detection and Alarm System | SDS | AH | Throughout Entire Building AHU Rooms Supply Duct | CERBERUS | ION | ||||||||
| FL0009ZZ-000000106 | Fire Detection and Alarm System | SDS | Throughout Entire Building | CERBERUS | ||||||||||
| FL0009ZZ-000000094 | Switchboard, Electrical | SWB | EE | Ground Floor Electrical Power Distribution Center (Primary Switchgear) | GENERAL ELEC | |||||||||
| FL0009ZZ-TNK-00001 | Tank, Size=500, Contents: Diesel, Used for: | TNK-01 | ||||||||||||
| FL0009ZZ-000000108 | Valves | VLV | SW | Stairwells and Landings Also in Fire Pump Room | ||||||||||
| FL0009ZZ-000000076 | Water Heater, Electric | WHT-01 | 01 | 1-133 | Floor 01 Warehouse / Storage Engineering Storage Room 1-133 | A.O. SMITH | DRE 120 917 | MH97-0673279-917 | ||||||
| FL0009ZZ-000000077 | Water Heater, Electric | WHT-01 | 01 | RRM | Floor 01 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0072823-917 | ||||||
| FL0009ZZ-000000078 | Water Heater, Electric | WHT-01 | 02 | RRM | Floor 02 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0072810-917 | ||||||
| FL0009ZZ-000000079 | Water Heater, Electric | WHT-01 | 03 | RRM | Floor 03 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0072811-917 | ||||||
| FL0009ZZ-000000080 | Water Heater, Electric | WHT-01 | 04 | RRM | Floor 04 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0085793-917 | ||||||
| FL0009ZZ-000000081 | Water Heater, Electric | WHT-01 | 05 | RRM | Floor 05 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0072821-917 | ||||||
| FL0009ZZ-000000082 | Water Heater, Electric | WHT-01 | 06 | RRM | Floor 06 Restroom Men's Rest Room | A.O. SMITH | ELJF -15 -J261161000 | MH97-0072822-917 | ||||||
| FL0009ZZ-000000095 | Water Softener | WSF | SP | Ground Floor Sally Port Inside Sally Port Garage | MVP CONTROL | 01017474 | V05135202 | |||||||
| FL0009ZZ-000000088 | Water Treatment (Chemical) | WTM | CH | PENTHOUSE Chiller Mechanical Room Next to Condenser Pumps | WTS, INC. | |||||||||