| GENERAL SERVICES ADMINISTRATION | DATE: | 5/20/16 |
| Bid Sheet |
| Building: | J.F. Weis Jr. Courthouse (PA0158) |
| Address: | 700 Grant Street |
| Pittsburgh, PA 15219 | |
| Project Name: | Construct Offices, US Attorneys |
| ITEM | DESCRIPTION OF WORK | QTY | UNIT | RATE | TOTAL |
| 001 | Scope clarification and assistance | MH | |||
| 002 | Laborer | MH | |||
| 003 | Electrician | MH | |||
| 005 | Carpenter | MH | |||
| 006 | Painter | MH | |||
| 010 | A/C Mechanic | MH | |||
| 011 | Carpet Installer | MH | |||
| 022 | Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface and remove from the Government property. | SY | |||
| 023 | Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface. | SY | |||
| 024 | Remove cove base molding or carpet base and remove from the Government property. | LF | |||
| 028 | Remove ceiling tile and/or suspension system, any type, and remove from the Government property. | SF | |||
| 032 | Remove telephone wall, data, or communication outlet and provide cover when needed. | EA | |||
| 046 | Disconnect electrical power, telephone, data, and CAT-5 cable from system furniture cubicle including 75'-0" of cable. | EA | |||
| 048 | Take back and recycling of old carpet products including freight to recycling facility | SY | |||
| 050 | F&I partition or ceiling 3-5/8", 25 gage metal stud 16" O.C., 5/8" drywall on both sides, including tape and spackle of drywall with primer or sealer coat of paint and 2 finish coats of paint. F&I 4" cove base. Price determined by SF of 1 side. | SF | |||
| 057 | Cut and patch opening into existing drywall or plaster, patching of the surface shall include all necessary work for a flush smooth surface to match the existing finish. | SF | |||
| 069 | Furnish and install mineral fiber sound insulation 3½" thick for walls or ceiling R13. | SF | |||
| 072 | F&I into any partition or masonry a door, solid wood core birch 3'-0" x 7'-0" x 1¾" with factory finished door and 16 gage hollow metal frame including painting the frame with two coats. F&I hardware to match building standard. | EA | |||
| 085 | Furnish and install building standard lockset and supply two keys. | EA | |||
| 089 | Furnish and install door stop or bumper, floor or wall mounted. | EA | |||
| 099 | Install Government furnished broadloom carpet per the manufactures instructions, contractor to supply all other items including adhesive, any preparation of the floor surface, etc., including removing and reinstalling all floor outlet covers. | SY | |||
| 105 | Furnish and install vinyl cove base ⅛" x 4" or 6" with molded corners. Contractor to supply samples or Government will provide selection of a manufacture and color. | LF | |||
| 108 | Furnish and install carpet binder bar beveled vinyl or beveled metal. Contractor to supply samples. | LF | |||
| 113 | Furnish and install suspended ceiling tile only into existing grid system 1'-0" x 4'-0" x ⅝", 2'-0" x 2'-0" x ⅝" or 2'-0" x 4'-0" x ⅝" lay-in type mineral fiber, fire rated ceiling tiles | SF | |||
| 114 | Furnish and Install ceiling, tile only, 2'x4', lay-in acrylic egg crate, 1/2" x 1/2" cubes, in existing grid system. | SF | |||
| 117 | Paint existing floors, ceiling, walls, or partitions, 1 finish coat, per side | SF | |||
| 118 | Paint or varnish door, two coats, per side, finish to be determined per each order | SF | |||
| 119 | Paint door frame, one side, 2 coats. The cost shall be per side | EA | |||
| 129 | Skim coating of existing wall or ceiling surface (drywall, CMU, etc.). | SF | |||
| 134 | Relocate Flex-duct extension, tap in collar, damper and register (all existing), collar adapter up to 14" x 16" max. Relocate up to 16'. | EA | |||
| 135 | Relocate Register/Damper and reroute flex duct. Relocate up to 16'. | EA | |||
| 136 | Relocate existing thermostat electric or pneumatic, including all necessary wiring and piping. | EA | |||
| 139 | Furnish and Install Flex Duct, insulated, up to 8" diameter. | LF | |||
| 140 | Furnish and Install Flex-Duct extension, tap in collar damper and register, to match existing, up to 10" diameter. | EA | |||
| 148 | Furnish and install piping insulation (1" wall fiberglass with all service jacket or ½" wall flexible closed cell foam rubber) for up to 2" piping as per the order. | LF | |||
| 149 | Furnish and install 24" x 24" lay-in type ceiling grid mounted grid mounted diffuser (Tbar, Round, or Perforated) with 8"-12" diameter neck & round butterfly damper, including up to 15' insulated flex duct, spin in collar, nylon ties, and connection into existing air supply duct. Grille to match or equal to existing building standard. | EA | |||
| 150 | Furnish and install 24" x 24" lay-in type ceiling grid mounted plenum air return grille (T Bar, Round, Eggcrate or Perforated type). Grille to match or equal to existing building standard. | EA | |||
| 152 | Rezone existing light fixture, light to be put on another circuit. Cost determined as one rezone per four fixtures. Rezoning light includes disconnecting and reconnecting of wiring and conduit. | EA | |||
| 153 | Relocate existing electrical wall outlet, switch, and power pole, including all necessary wiring and conduit. Also including patching and painting of existing location, or furnish and install blank cover as indicated on the order. | EA | |||
| 162 | Furnish and Install Switch, wall, dimmer, 120/277 V, 20 Amp (minimum), fluorescent. | EA | |||
| 165 | Furnish and install electrical duplex wall outlet 20 or 30 amp, 120, 208, or 220 volts. Connect to power source as directed using MC Cable up to 50'-0" of wiring. All circuits shall be labeled on the panel board, outlet, and print. | EA | |||
| 166 | Furnish and Install Receptacle, Dedicated duplex, wall 120/208/220 V, 20 Amp. | EA | |||
| 168 | Furnish and Install Receptacle, Dedicated Quadraplex, wall 120/208/220 V, 20 Amp (minimum). | EA | |||
| 174 | Furnish and Install Blank Cover, only, for telephone or electrical outlet, wall. | EA | |||
| 187 | Furnish and Install raceways and conductors, conduit (EMT ½" or ¾"), and wire. | LF | |||
| 195 | Furnish and install telephone or data wall outlet box with ½" grommet hole blank plate in the wall and extend ¾" EMT conduit or greenfield per the order to an accessible ceiling location and provide pull string. | EA | |||
| 209 | Furnish and Install Armored MC Cable, 4 wire, #12 AWG. | LF | |||
| Custom | Asbestos pre-alteration assessment | EA | |||
| Custom | Bonding | Job |
| LINE ITEM TOTAL: | $0.00 |
| ADMINISTRATIVE: | $0.00 |
| OVERHEAD & PROFIT: | $0.00 |
GRAND TOTAL: $0.00