Sheet1

GENERAL SERVICES ADMINISTRATIONDATE:5/20/16
Bid Sheet
Building:J.F. Weis Jr. Courthouse (PA0158)
Address:700 Grant Street
Pittsburgh, PA 15219
Project Name:Construct Offices, US Attorneys
ITEMDESCRIPTION OF WORKQTYUNITRATETOTAL
001Scope clarification and assistanceMH
002LaborerMH
003ElectricianMH
005CarpenterMH
006PainterMH
010A/C MechanicMH
011Carpet InstallerMH
022Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface and remove from the Government property.SY
023Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.SY
024Remove cove base molding or carpet base and remove from the Government property.LF
028Remove ceiling tile and/or suspension system, any type, and remove from the Government property.SF
032Remove telephone wall, data, or communication outlet and provide cover when needed.EA
046Disconnect electrical power, telephone, data, and CAT-5 cable from system furniture cubicle including 75'-0" of cable.EA
048Take back and recycling of old carpet products including freight to recycling facilitySY
050F&I partition or ceiling 3-5/8", 25 gage metal stud 16" O.C., 5/8" drywall on both sides, including tape and spackle of drywall with primer or sealer coat of paint and 2 finish coats of paint. F&I 4" cove base. Price determined by SF of 1 side.SF
057Cut and patch opening into existing drywall or plaster, patching of the surface shall include all necessary work for a flush smooth surface to match the existing finish.SF
069Furnish and install mineral fiber sound insulation 3½" thick for walls or ceiling R13.SF
072F&I into any partition or masonry a door, solid wood core birch 3'-0" x 7'-0" x 1¾" with factory finished door and 16 gage hollow metal frame including painting the frame with two coats. F&I hardware to match building standard.EA
085Furnish and install building standard lockset and supply two keys.EA
089Furnish and install door stop or bumper, floor or wall mounted.EA
099Install Government furnished broadloom carpet per the manufactures instructions, contractor to supply all other items including adhesive, any preparation of the floor surface, etc., including removing and reinstalling all floor outlet covers.SY
105Furnish and install vinyl cove base ⅛" x 4" or 6" with molded corners. Contractor to supply samples or Government will provide selection of a manufacture and color.LF
108Furnish and install carpet binder bar beveled vinyl or beveled metal. Contractor to supply samples.LF
113Furnish and install suspended ceiling tile only into existing grid system 1'-0" x 4'-0" x ⅝", 2'-0" x 2'-0" x ⅝" or 2'-0" x 4'-0" x ⅝" lay-in type mineral fiber, fire rated ceiling tilesSF
114Furnish and Install ceiling, tile only, 2'x4', lay-in acrylic egg crate, 1/2" x 1/2" cubes, in existing grid system.SF
117Paint existing floors, ceiling, walls, or partitions, 1 finish coat, per sideSF
118Paint or varnish door, two coats, per side, finish to be determined per each orderSF
119Paint door frame, one side, 2 coats. The cost shall be per sideEA
129Skim coating of existing wall or ceiling surface (drywall, CMU, etc.).SF
134Relocate Flex-duct extension, tap in collar, damper and register (all existing), collar adapter up to 14" x 16" max. Relocate up to 16'.EA
135Relocate Register/Damper and reroute flex duct. Relocate up to 16'.EA
136Relocate existing thermostat electric or pneumatic, including all necessary wiring and piping.EA
139Furnish and Install Flex Duct, insulated, up to 8" diameter.LF
140Furnish and Install Flex-Duct extension, tap in collar damper and register, to match existing, up to 10" diameter.EA
148Furnish and install piping insulation (1" wall fiberglass with all service jacket or ½" wall flexible closed cell foam rubber) for up to 2" piping as per the order.LF
149Furnish and install 24" x 24" lay-in type ceiling grid mounted grid mounted diffuser (Tbar, Round, or Perforated) with 8"-12" diameter neck & round butterfly damper, including up to 15' insulated flex duct, spin in collar, nylon ties, and connection into existing air supply duct. Grille to match or equal to existing building standard.EA
150Furnish and install 24" x 24" lay-in type ceiling grid mounted plenum air return grille (T Bar, Round, Eggcrate or Perforated type). Grille to match or equal to existing building standard.EA
152Rezone existing light fixture, light to be put on another circuit. Cost determined as one rezone per four fixtures. Rezoning light includes disconnecting and reconnecting of wiring and conduit.EA
153Relocate existing electrical wall outlet, switch, and power pole, including all necessary wiring and conduit. Also including patching and painting of existing location, or furnish and install blank cover as indicated on the order.EA
162Furnish and Install Switch, wall, dimmer, 120/277 V, 20 Amp (minimum), fluorescent.EA
165Furnish and install electrical duplex wall outlet 20 or 30 amp, 120, 208, or 220 volts. Connect to power source as directed using MC Cable up to 50'-0" of wiring. All circuits shall be labeled on the panel board, outlet, and print.EA
166Furnish and Install Receptacle, Dedicated duplex, wall 120/208/220 V, 20 Amp.EA
168Furnish and Install Receptacle, Dedicated Quadraplex, wall 120/208/220 V, 20 Amp (minimum).EA
174Furnish and Install Blank Cover, only, for telephone or electrical outlet, wall.EA
187Furnish and Install raceways and conductors, conduit (EMT ½" or ¾"), and wire.LF
195Furnish and install telephone or data wall outlet box with ½" grommet hole blank plate in the wall and extend ¾" EMT conduit or greenfield per the order to an accessible ceiling location and provide pull string.EA
209Furnish and Install Armored MC Cable, 4 wire, #12 AWG.LF
CustomAsbestos pre-alteration assessmentEA
CustomBondingJob
LINE ITEM TOTAL:$0.00