GRU_Mobile_and_Transformer_Asbestos,_Bulk_Sample_Analytical_Results.pdf

PDF 2 MB Posted

Attached to
Demolition, Asbestos Abatement, Lead Paint & Hazardous Materials Removal
Solicitation number
2026-063
Issued by
Alachua County, Graceville City, Florida

About this file

This is an analytical results report from EMSL Analytical, Inc., a laboratory in Kernersville, North Carolina, documenting asbestos and bulk sample testing conducted for GLE Associates on behalf of GRU Mobile and Transformer materials. The samples were collected on November 21, 2025, and received by the laboratory on November 24, 2025, with analytical results reported on November 26, 2025. The analysis examined chip matrix samples from a client identified as L-01, with lead content being one of the analytes tested. The results documentation includes standard laboratory reference identifiers, chain of custody information, and analytical methodology employed by EMSL Analytical technicians.

The report contains limited pricing or contractual terms within the document itself, as it serves primarily as a technical analytical deliverable rather than a procurement or bidding document. The sample analysis was commissioned by GLE Associates, located in Gainesville, Florida, and appears connected to a larger environmental assessment or remediation project. The analytical work was completed within a two-day turnaround from sample receipt, indicating expedited laboratory processing. No set-asides, incumbent information, or funding source details are specified within the analytical results document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Name:

Customer PO:

EMSL Sales Rep:

Reported:

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC, 27284

Telephone: (336)-992-1025 Fax:(336)-992-4175 www.emsl.com

Attention:

Received: 11/24/2025 08:30

11/26/2025 17:27

Jason McDonald

EMSL Order ID: 022550770

LIMS Reference ID: KD50770

EMSL Customer ID: GLEA51B

25000-32247 GRU Mobile/TransMike Harrell

GLE Associates [GLEA51B]

2610 NW 43rd Street, Suite 2A

Gainesville, FL 32606

(352) 335-6648 mharrell@gleassociates.com

Analytical Results

Analyte Results RL Q DF Analysis Date

& AnalystWeight(g)

Prep Date

& Tech

Analytical

MethodPrep Method

Client Sample ID: L-01 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-01

1Lead 11/26/25 JC 11/26/25 JC<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2873

Sample Comments:

Client Sample ID: L-02 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-02

1Lead 11/26/25 JC 11/26/25 JC<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2915

Sample Comments:

Client Sample ID: L-03 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-03

1Lead 11/26/25 JC 11/26/25 JC0.0098 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.3204

Sample Comments:

Client Sample ID: L-04 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-04

1Lead 11/26/25 JC 11/26/25 JC<0.0380 % wt 0.0380 % wt SW-846 3050B SW 846-7000B0.0421

Sample Comments:

Client Sample ID: L-05 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-05

1Lead 11/26/25 JC 11/26/25 JC0.0344 % wt 0.0083 % wt SW-846 3050B SW 846-7000B0.1924

Sample Comments:

Client Sample ID: L-06 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-06

1Lead 11/26/25 JC 11/26/25 JC<0.0124 % wt 0.0124 % wt SW-846 3050B SW 846-7000B0.1291

Sample Comments:

Client Sample ID: L-07 Date Sampled: 11/21/25

Matrix: Chips LIMS Reference ID: KD50770-07

1Lead 11/26/25 JC 11/26/25 JC0.0574 % wt 0.0159 % wt SW-846 3050B SW 846-7000B0.1007

Sample Comments:

[TOC_1]Sample Results[TOC]

EMSL Sales Rep:

Reported:

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC, 27284

Telephone: (336)-992-1025 Fax:(336)-992-4175 www.emsl.com

Attention:

Received: 11/24/2025 08:30

11/26/2025 17:27

Jason McDonald

EMSL Order ID: 022550770

LIMS Reference ID: KD50770

EMSL Customer ID: GLEA51B

25000-32247 GRU Mobile/TransMike Harrell

GLE Associates [GLEA51B]

2610 NW 43rd Street, Suite 2A

Gainesville, FL 32606

(352) 335-6648 mharrell@gleassociates.com

CertificationsAnalyte

Certified Analyses included in this Report

SW 846-7000B in Chips

02-AIHA ELLAPLead

[TOC_1]Certified

Analyses[TOC]

List of Certifications

Code Description Number Expires

02-AIHA ELLAP 102564American Industrial Hygiene Association (AIHA LAP, LLC) - ELLAP 06/01/2026

02-AIHA EMLAP 102564American Industrial Hygiene Association (AIHA LAP, LLC) - EMLAP 06/01/2026

Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.

[TOC_1]Certifications[TOC]

Notes and Definitions

Item Definition

(Dig) For metals analysis, sample was digested.

[2C] Reported from the second channel in dual column analysis.

DA Direct Analysis

DF Dilution Factor

MDL Method Detection Limit.

ND Analyte was NOT DETECTED at or above the detection limit.

NR Spike/Surrogate showed no recovery.

Q Qualifier

RCS Respirable Crystalline Silica

RL Reporting Limit

Wet Sample is not dry weight corrected.

Measurement of uncertainty and any applicable definitions of method modifications are available upon request. Per EPA NLLAP policy, sample results are not blank corrected.

[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]

EMSL Sales Rep:

Reported:

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC, 27284

Telephone: (336)-992-1025 Fax:(336)-992-4175 www.emsl.com

Attention:

Received: 11/24/2025 08:30

11/26/2025 17:27

Jason McDonald

EMSL Order ID: 022550770

LIMS Reference ID: KD50770

EMSL Customer ID: GLEA51B

25000-32247 GRU Mobile/TransMike Harrell

GLE Associates [GLEA51B]

2610 NW 43rd Street, Suite 2A

Gainesville, FL 32606

(352) 335-6648 mharrell@gleassociates.com

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. QC sample results are within quality control criteria and met method specifications unless otherwise noted. All results for soil samples are reported on a dry weight basis, unless otherwise noted.

James Cole Laboratory Manager or other approved signatory

Analysis following EMSL SOP for the Determination of Environmental Lead by FLAA. The laboratory has a reporting limit of 0.0064% by wt., based upon a minimum sample weight of

0.25g submitted to the lab, and is not responsible for any result or reporting limit provided in mg/cm2 since it is dependent upon an area value provided by non-lab personnel. A "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty and definitions of modifications are available upon request. Results in this report are not blank corrected unless specified.

Sample Results
Certified Analyses
Certifications
Qualifiers, Definitions and Disclaimer
Chain of Custody PDF

File details come from the government source that posted it. Updated .