This is an Assessment Summary Report prepared for the State of Rhode Island's Department of Behavioral Healthcare, Developmental Disabilities and Hospitals (BHDDH) regarding the demolition project of a former group home located at 22 Tartaglia Street in Johnston, Rhode Island. The project scope requires the selected contractor to demolish the entire structure to slab level, fill and stabilize the site with temporary vegetation, and manage all associated permitting requirements. A pre-bid site visit and information meeting is scheduled for October 16, 2026, at 12:00 PM EST at the project location (22 Tartaglia Street, Johnston, RI 02919).
The assessment report provides technical and environmental documentation to support the bidding process, including structural conditions and site analysis necessary for contractors to develop accurate demolition proposals. The report serves as a foundational reference document enabling qualified firms to understand project requirements, assess site conditions, and submit competitive bids. No specific pricing terms, contract award date, or contract term duration is detailed within this assessment document, as it functions as a pre-bid informational resource rather than a final procurement notice.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS DETERMINATION SURVEY
Conducted At:
Group Residential Building
22 Tartaglia Street
Johnston, RI 02919
Prepared For:
GMIarchitects – Bristol Studio
412A Thames Street
Briston, RI 02809
Attention: Damara Toohey
Prepared By:
Brendon Cooney – MA AI900689
MAC Services
21 Mill Pond Drive
Rochester, MA 02770
Reviewed By:
Joseph Cooney – RI AI00829
April 6, 2026
Asbestos Determination Survey
Table of Contents:
Page
Project Summary 3
Section I
A. Scope of Work 3-4
B. Description of Survey 4-5
Section II
Bulk Sample Analytical Summary 5
Tables
List of Tables: 5
Table 1: Suspect Building Materials 6-8
BULK Asbestos Sample Analytical Data 9-29
PROJECT SUMMARY
On March 23rd, 2026, MAC Services (MAC) conducted a limited asbestos determination survey for all accessible materials from the group residential building located at 22 Tartaglia Street in Johnston, RI.
The intent of the inspection was to conduct a NESHAP demolition inspection.
The survey focused on all suspected homogenous building materials. In total, there were fifty-two, (52), samples obtained representing twenty-six, (26), suspect building materials. All suspect building material samples collected were determined to be NON-asbestos containing. All sampled materials suspected of containing asbestos are listed in Table 1.
If during the renovation process any suspect looking materials not listed in this report are uncovered from layers below the surface of floors, walls and ceilings by demolition personnel, they must stop all activity around the uncovered material until it is determined if that suspect material is asbestos. MAC
Services is not responsible for any hidden or concealed items or building materials.
SECTION I
Section one of this report details the survey methodology and scope of investigation.
A. SCOPE OF WORK
The space specified for Asbestos Containing Building Material (ACBM) determination was inspected by
Massachusetts Licensed Inspector, Joseph Cooney, (AI000187), collected bulk samples, assessed the physical condition of the materials suspected of being asbestos containing, and completed the field survey forms. The inspector is experienced and has conducted previous asbestos surveys, specifications, asbestos air sample analysis, and monitoring as well as reporting of asbestos repair and removal projects.
Standardized forms were used to gather data, including chain of custody records to accompany samples to the laboratory.
Samples were collected adhering to AHERA regulations and guidelines which dictates that multiple samples per suspect material must be obtained depending on the material type and existing homogenous quantity, with each separate homogenous area of material sampled. Materials are broken down into three separate categories described as follows:
Surfacing Material (SM): is defined as material that is sprayed on, troweled on, or otherwise permanently applied to surfaces, such as acoustical plaster on ceilings, and fireproofing materials on structural members, or other materials on surfaces for acoustical, fireproofing, or other purposes.
Thermal System Insulation (TSI): are materials applied to pipes, fittings, boilers, breaching, tanks, ducts, or interior structural components to prevent heat loss or water condensation, or for other purposes.
Miscellaneous Material (MM): are interior and exterior building material on structural components, structural members or fixtures, such as floor and ceiling tiles, and vinyl sheeting and does not include surfacing material or thermal systems insulation.
Some definitions of terms are as follows:
A homogeneous material is a surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture.
A friable material is one which, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable materials typically contain bonding agents (e.g., cement, plastics, asphalt, and glue) that lock the asbestos fibers into the product. The inspector identified all visible flooring material that could potentially contain asbestos.
ACBM is an Asbestos Containing Building Material
AHERA stands for Asbestos Hazard Emergency Response Act
B. SAMPLING SURVEY
MAC has developed standard procedures to be used in order to randomly sample each material suspected of being asbestos containing. In order to classify any homogeneous material as a non-asbestos containing building material, a sufficient number of samples are collected and analyzed. All samples analyzed must show the lack of asbestos content (less than one percent asbestos) in order to be considered non-asbestos containing. If a material has trace amounts of asbestos (less than 1%) the material is not considered
‘Asbestos Containing’ and therefore, doesn’t have to be removed as asbestos containing, however, it must still be disposed of as asbestos containing.
Samples were taken and logged in on a chain of custody form and delivered to Asbestos Identification
Laboratory of Woburn, MA for analysis. The bulk samples were analyzed by polarized light microscopy
(PLM) (EPA Interim Method: Appendix A of Subpart F-40 CFR Part 763 and/or EPA 600/R-93/116).
Asbestos Identification Lab is licensed by the Commonwealth of Massachusetts (#AA 000208) for bulk asbestos analysis and is a NVLAP accredited laboratory.
CLASSIFICATION OF MATERIAL CONDITION
Where applicable, all identified asbestos containing material is classified as to physical condition as follows:
GOOD (G):
Asbestos containing building material in good condition at the time of the survey was whole and complete and typical of newer installation.
DAMAGED (D):
Asbestos containing building material in damaged condition at the time of the survey was generally complete but showed some signs of damage or deterioration. Material is classified as damaged when the damage or deterioration covers less than one tenth of the material's surface and is evenly distributed, or when it covers less than one quarter of the material's surface and is localized. This material typically needs attention but does not constitute emergency removal.
SIGNIFICANTLY DAMAGED (SD):
Asbestos containing building material is determined to be significantly damaged when at the time of the survey, the material was damaged or deteriorated, often with pieces missing. A material is classified as significantly damaged when the damage/deterioration covers more than one tenth of the material's surface and is evenly distributed, or when it covers more than one quarter of the material’s surface and is localized.
SECTION II
ANALYTICAL DATA
Fifty-two, (52), samples of materials suspected to be asbestos containing were collected and analyzed.
Analytical Data is presented on the following pages. All sampled materials suspected of containing asbestos are identified in Table 1. Twenty-six, (26), materials, represented by fifty-two, (52), samples obtained were determined to be non-asbestos containing. Multiple samples of each suspect material are required per the AHERA regulations.
Table 1:
"Suspect Homogeneous Building Materials", lists all building materials related to the planned renovations/demolition, suspected of containing asbestos. Asbestos containing materials are divided into the three categories established by the U.S. Environmental Protection Agency under the Asbestos Hazard
Emergency Response Act (AHERA): Thermal Systems Insulation (TSI) Surfacing Material (SM), and
Miscellaneous Material (MM). Each material is identified by the appropriate two-letter prefix.
TABLE 1
SUSPECT ASBESTOS CONTAINING BUILDING MATERIALS SAMPLED
Sample Field
ID
Description Location Color Material
Type
01A Textured Plaster Dining Area Ceiling White SM
01B Textured Plaster Basement Main Area Ceiling White SM
02A Gypsum Board Dining Area Ceiling Off White M
02B Gypsum Board Basement Storage Room Wall Off White MM
03A White Skim Coat
Plaster
Dining Area Wall White SM
03B White Skim Coat
Plaster
Basement Storage Room Wall White SM
04A Tan Stone Pattern
Linoleum
Kitchen Multi MM
04B Tan Stone Pattern
Linoleum
Hall at Exit Multi MM
05A Glue with 04A Kitchen Tan MM
05B Glue with 04B Hall at Exit Tan MM
06A 12”x12” Brown
Speck Pattern Floor
Tile
Bedroom next to Stairwell Light
Brown
MM
06B 12”x12” Brown
Speck Pattern Floor
Tile
Bedroom next to Stairwell Light
Brown
MM
07A Mastic with 06A Bedroom next to Stairwell Tan MM
07B Mastic with 06B Bedroom next to Stairwell Tan MM
08A 4” Brown Cove Base Bathroom near Stairwell Light
Brown
MM
08B 4” Brown Cove Base Bathroom near Stairwell Light
Brown
MM
09A Mastic with 08A Bathroom near Stairwell Tan MM
09B Mastic with 08B Bathroom near Stairwell Tan MM
10A 6”x6” Ceramic Tile
Grout
Bathroom next to Kitchen White MM
10B 6”x6” Ceramic Tile
Grout
Bathroom next to Kitchen White MM
11A 6”x6” Ceramic Tile
Glue
Bathroom next to Kitchen Off White MM
Description Location Color Material
Type
11B 6”x6” Ceramic Tile
Glue
Bathroom next to Kitchen Off White MM
12A 2”x6” White Ceramic
Tile Grout
Kitchen White MM
12B 2”x6” White Ceramic
Tile Grout
Kitchen White MM
13A 2”x6” White Ceramic
Tile Glue
Kitchen Off White MM
13B 2”x6” White Ceramic
Tile Glue
Kitchen Off White MM
14A Light Tan Stone
Pattern Linoleum
Corner Bedroom near Kitchen Multi MM
14B Light Tan Stone
Pattern Linoleum
Corner Bedroom near Kitchen Multi MM
15A Glue with 14A Corner Bedroom near Kitchen Grey MM
15B Glue with 14B Corner Bedroom near Kitchen MM
16A Brown Speck Pattern
Linoleum
Bedroom Across from (2) Bathrooms Multi MM
16B Brown Speck Pattern
Linoleum
Bedroom Across from (2) Bathrooms Multi MM
17A Glue with 16A Bedroom Across from (2) Bathrooms Tan MM
17B Glue with 16B Bedroom Across from (2) Bathrooms Tan MM
18A 4”x4” Ceramic Tile
Grout
Bathroom near Driveway Side Exit White MM
18B 4”x4” Ceramic Tile
Grout
Bathroom near Driveway Side Exit White MM
19A 4”x4” Ceramic Tile
Glue
Bathroom near Driveway Side Exit Tan MM
19B 4”x4” Ceramic Tile
Glue
Bathroom near Driveway Side Exit Tan MM
20A 1”x1” Ceramic Tile
Grout
Bathroom near Driveway Side Exit Grey MM
20B 1”x1” Ceramic Tile
Grout
Bathroom near Driveway Side Exit Grey MM
21A 1”x1” Ceramic Tile
Glue
Bathroom near Driveway Side Exit Grey MM
Description Location Color Material
Type
21B 1”x1” Ceramic Tile
Glue
Bathroom near Driveway Side Exit Grey MM
22A Carpet Glue Hall near Kitchen Tan MM
22B Carpet Glue Hall near Kitchen Tan MM
23A Epoxy Flooring Bathroom near Stairwell Multi MM
23B Epoxy Flooring Bathroom near Kitchen Multi MM
24A Grey Asphalt Roof
Shingle
Exterior – Roof at Front Black MM
24B Grey Asphalt Roof
Shingle
Exterior – Roof at Front Black MM
25A Black Tar Paper Exterior – Roof at Front Black MM
25B Black Tar Paper Exterior – Roof at Front Black MM
26A Black Vapor Barrier
Sheeting
Exterior – Behind Vinyl Siding at Rear
Corner
Black MM
26B Black Vapor Barrier
Sheeting
Exterior – Behind Vinyl Siding at Rear
Corner
Black MM
BULK ASBESTOS SAMPLE ANALYTICAL DATA