About this file

This is an Assessment Summary Report prepared for the State of Rhode Island's Department of Behavioral Healthcare, Developmental Disabilities and Hospitals (BHDDH) regarding the demolition project of a former group home located at 22 Tartaglia Street in Johnston, Rhode Island. The project scope requires the selected contractor to demolish the entire structure to slab level, fill and stabilize the site with temporary vegetation, and manage all associated permitting requirements. A pre-bid site visit and information meeting is scheduled for October 16, 2026, at 12:00 PM EST at the project location (22 Tartaglia Street, Johnston, RI 02919).

The assessment report provides technical and environmental documentation to support the bidding process, including structural conditions and site analysis necessary for contractors to develop accurate demolition proposals. The report serves as a foundational reference document enabling qualified firms to understand project requirements, assess site conditions, and submit competitive bids. No specific pricing terms, contract award date, or contract term duration is detailed within this assessment document, as it functions as a pre-bid informational resource rather than a final procurement notice.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS DETERMINATION SURVEY

Conducted At:

Group Residential Building

22 Tartaglia Street

Johnston, RI 02919

Prepared For:

GMIarchitects – Bristol Studio

412A Thames Street

Briston, RI 02809

Attention: Damara Toohey

Prepared By:

Brendon Cooney – MA AI900689

MAC Services

21 Mill Pond Drive

Rochester, MA 02770

Reviewed By:

Joseph Cooney – RI AI00829

April 6, 2026

Asbestos Determination Survey

Table of Contents:

Page

Project Summary 3

Section I

A. Scope of Work 3-4

B. Description of Survey 4-5

Section II

Bulk Sample Analytical Summary 5

Tables

List of Tables: 5

Table 1: Suspect Building Materials 6-8

BULK Asbestos Sample Analytical Data 9-29

PROJECT SUMMARY

On March 23rd, 2026, MAC Services (MAC) conducted a limited asbestos determination survey for all accessible materials from the group residential building located at 22 Tartaglia Street in Johnston, RI.

The intent of the inspection was to conduct a NESHAP demolition inspection.

The survey focused on all suspected homogenous building materials. In total, there were fifty-two, (52), samples obtained representing twenty-six, (26), suspect building materials. All suspect building material samples collected were determined to be NON-asbestos containing. All sampled materials suspected of containing asbestos are listed in Table 1.

If during the renovation process any suspect looking materials not listed in this report are uncovered from layers below the surface of floors, walls and ceilings by demolition personnel, they must stop all activity around the uncovered material until it is determined if that suspect material is asbestos. MAC

Services is not responsible for any hidden or concealed items or building materials.

SECTION I

Section one of this report details the survey methodology and scope of investigation.

A. SCOPE OF WORK

The space specified for Asbestos Containing Building Material (ACBM) determination was inspected by

Massachusetts Licensed Inspector, Joseph Cooney, (AI000187), collected bulk samples, assessed the physical condition of the materials suspected of being asbestos containing, and completed the field survey forms. The inspector is experienced and has conducted previous asbestos surveys, specifications, asbestos air sample analysis, and monitoring as well as reporting of asbestos repair and removal projects.

Standardized forms were used to gather data, including chain of custody records to accompany samples to the laboratory.

Samples were collected adhering to AHERA regulations and guidelines which dictates that multiple samples per suspect material must be obtained depending on the material type and existing homogenous quantity, with each separate homogenous area of material sampled. Materials are broken down into three separate categories described as follows:

Surfacing Material (SM): is defined as material that is sprayed on, troweled on, or otherwise permanently applied to surfaces, such as acoustical plaster on ceilings, and fireproofing materials on structural members, or other materials on surfaces for acoustical, fireproofing, or other purposes.

Thermal System Insulation (TSI): are materials applied to pipes, fittings, boilers, breaching, tanks, ducts, or interior structural components to prevent heat loss or water condensation, or for other purposes.

Miscellaneous Material (MM): are interior and exterior building material on structural components, structural members or fixtures, such as floor and ceiling tiles, and vinyl sheeting and does not include surfacing material or thermal systems insulation.

Some definitions of terms are as follows:

A homogeneous material is a surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture.

A friable material is one which, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable materials typically contain bonding agents (e.g., cement, plastics, asphalt, and glue) that lock the asbestos fibers into the product. The inspector identified all visible flooring material that could potentially contain asbestos.

ACBM is an Asbestos Containing Building Material

AHERA stands for Asbestos Hazard Emergency Response Act

B. SAMPLING SURVEY

MAC has developed standard procedures to be used in order to randomly sample each material suspected of being asbestos containing. In order to classify any homogeneous material as a non-asbestos containing building material, a sufficient number of samples are collected and analyzed. All samples analyzed must show the lack of asbestos content (less than one percent asbestos) in order to be considered non-asbestos containing. If a material has trace amounts of asbestos (less than 1%) the material is not considered

‘Asbestos Containing’ and therefore, doesn’t have to be removed as asbestos containing, however, it must still be disposed of as asbestos containing.

Samples were taken and logged in on a chain of custody form and delivered to Asbestos Identification

Laboratory of Woburn, MA for analysis. The bulk samples were analyzed by polarized light microscopy

(PLM) (EPA Interim Method: Appendix A of Subpart F-40 CFR Part 763 and/or EPA 600/R-93/116).

Asbestos Identification Lab is licensed by the Commonwealth of Massachusetts (#AA 000208) for bulk asbestos analysis and is a NVLAP accredited laboratory.

CLASSIFICATION OF MATERIAL CONDITION

Where applicable, all identified asbestos containing material is classified as to physical condition as follows:

GOOD (G):

Asbestos containing building material in good condition at the time of the survey was whole and complete and typical of newer installation.

DAMAGED (D):

Asbestos containing building material in damaged condition at the time of the survey was generally complete but showed some signs of damage or deterioration. Material is classified as damaged when the damage or deterioration covers less than one tenth of the material's surface and is evenly distributed, or when it covers less than one quarter of the material's surface and is localized. This material typically needs attention but does not constitute emergency removal.

SIGNIFICANTLY DAMAGED (SD):

Asbestos containing building material is determined to be significantly damaged when at the time of the survey, the material was damaged or deteriorated, often with pieces missing. A material is classified as significantly damaged when the damage/deterioration covers more than one tenth of the material's surface and is evenly distributed, or when it covers more than one quarter of the material’s surface and is localized.

SECTION II

ANALYTICAL DATA

Fifty-two, (52), samples of materials suspected to be asbestos containing were collected and analyzed.

Analytical Data is presented on the following pages. All sampled materials suspected of containing asbestos are identified in Table 1. Twenty-six, (26), materials, represented by fifty-two, (52), samples obtained were determined to be non-asbestos containing. Multiple samples of each suspect material are required per the AHERA regulations.

Table 1:

"Suspect Homogeneous Building Materials", lists all building materials related to the planned renovations/demolition, suspected of containing asbestos. Asbestos containing materials are divided into the three categories established by the U.S. Environmental Protection Agency under the Asbestos Hazard

Emergency Response Act (AHERA): Thermal Systems Insulation (TSI) Surfacing Material (SM), and

Miscellaneous Material (MM). Each material is identified by the appropriate two-letter prefix.

TABLE 1

SUSPECT ASBESTOS CONTAINING BUILDING MATERIALS SAMPLED

Sample Field

ID

Description Location Color Material

Type

01A Textured Plaster Dining Area Ceiling White SM

01B Textured Plaster Basement Main Area Ceiling White SM

02A Gypsum Board Dining Area Ceiling Off White M

02B Gypsum Board Basement Storage Room Wall Off White MM

03A White Skim Coat

Plaster

Dining Area Wall White SM

03B White Skim Coat

Plaster

Basement Storage Room Wall White SM

04A Tan Stone Pattern

Linoleum

Kitchen Multi MM

04B Tan Stone Pattern

Linoleum

Hall at Exit Multi MM

05A Glue with 04A Kitchen Tan MM

05B Glue with 04B Hall at Exit Tan MM

06A 12”x12” Brown

Speck Pattern Floor

Tile

Bedroom next to Stairwell Light

Brown

MM

06B 12”x12” Brown

Speck Pattern Floor

Tile

Bedroom next to Stairwell Light

Brown

MM

07A Mastic with 06A Bedroom next to Stairwell Tan MM

07B Mastic with 06B Bedroom next to Stairwell Tan MM

08A 4” Brown Cove Base Bathroom near Stairwell Light

Brown

MM

08B 4” Brown Cove Base Bathroom near Stairwell Light

Brown

MM

09A Mastic with 08A Bathroom near Stairwell Tan MM

09B Mastic with 08B Bathroom near Stairwell Tan MM

10A 6”x6” Ceramic Tile

Grout

Bathroom next to Kitchen White MM

10B 6”x6” Ceramic Tile

Grout

Bathroom next to Kitchen White MM

11A 6”x6” Ceramic Tile

Glue

Bathroom next to Kitchen Off White MM

Description Location Color Material

Type

11B 6”x6” Ceramic Tile

Glue

Bathroom next to Kitchen Off White MM

12A 2”x6” White Ceramic

Tile Grout

Kitchen White MM

12B 2”x6” White Ceramic

Tile Grout

Kitchen White MM

13A 2”x6” White Ceramic

Tile Glue

Kitchen Off White MM

13B 2”x6” White Ceramic

Tile Glue

Kitchen Off White MM

14A Light Tan Stone

Pattern Linoleum

Corner Bedroom near Kitchen Multi MM

14B Light Tan Stone

Pattern Linoleum

Corner Bedroom near Kitchen Multi MM

15A Glue with 14A Corner Bedroom near Kitchen Grey MM

15B Glue with 14B Corner Bedroom near Kitchen MM

16A Brown Speck Pattern

Linoleum

Bedroom Across from (2) Bathrooms Multi MM

16B Brown Speck Pattern

Linoleum

Bedroom Across from (2) Bathrooms Multi MM

17A Glue with 16A Bedroom Across from (2) Bathrooms Tan MM

17B Glue with 16B Bedroom Across from (2) Bathrooms Tan MM

18A 4”x4” Ceramic Tile

Grout

Bathroom near Driveway Side Exit White MM

18B 4”x4” Ceramic Tile

Grout

Bathroom near Driveway Side Exit White MM

19A 4”x4” Ceramic Tile

Glue

Bathroom near Driveway Side Exit Tan MM

19B 4”x4” Ceramic Tile

Glue

Bathroom near Driveway Side Exit Tan MM

20A 1”x1” Ceramic Tile

Grout

Bathroom near Driveway Side Exit Grey MM

20B 1”x1” Ceramic Tile

Grout

Bathroom near Driveway Side Exit Grey MM

21A 1”x1” Ceramic Tile

Glue

Bathroom near Driveway Side Exit Grey MM

Description Location Color Material

Type

21B 1”x1” Ceramic Tile

Glue

Bathroom near Driveway Side Exit Grey MM

22A Carpet Glue Hall near Kitchen Tan MM

22B Carpet Glue Hall near Kitchen Tan MM

23A Epoxy Flooring Bathroom near Stairwell Multi MM

23B Epoxy Flooring Bathroom near Kitchen Multi MM

24A Grey Asphalt Roof

Shingle

Exterior – Roof at Front Black MM

24B Grey Asphalt Roof

Shingle

Exterior – Roof at Front Black MM

25A Black Tar Paper Exterior – Roof at Front Black MM

25B Black Tar Paper Exterior – Roof at Front Black MM

26A Black Vapor Barrier

Sheeting

Exterior – Behind Vinyl Siding at Rear

Corner

Black MM

26B Black Vapor Barrier

Sheeting

Exterior – Behind Vinyl Siding at Rear

Corner

Black MM

BULK ASBESTOS SAMPLE ANALYTICAL DATA