GGG Final Drawings.pdf
PDF 11 MB Posted
- Solicitation number
- 697DCK-21-R-00163
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
g g -1
-g
.d g n
/1
/2
:5
:0
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
DP.1
T
EM
EX
SPD
GND
RGS
EES
EMT
FT
J-BOX
MTS
NO.
COMM
RF
PVC
LOC
SER
SPD
C
GFCI
E/G
BFL
GFE
SCH
TYP
ATCT
ELECTRICAL CONDUIT AND WIRING
WITH 2 NO.12 WIRES PLUS 1 NO.12 GROUND
BRANCH CIRCUIT, SURFACE MOUNTED 3/4"C,
WHEN MORE THAN 3 IN 3/4" CONDUIT
CROSS MARKS DENOTE NUMBER OF NO.12 WIRES
SAME AS BRANCH CIRCUIT - BUT CONCEALED
SOLID WHETHER CONCEALED OR EXPOSED
HOME RUN TO PANEL DP CIRCUIT 1, SHOWN
CONDUIT, CAPPED
CONDUIT, FLEXIBLE
CONDUIT DOWN
CONDUIT UP
TRANSFORMER
EXOTHERMIC WELD
FUSE, 15A
WITH EXOTHERMIC WELD
GROUND ROD 3/4"x 10’-0"
GROUND WELL
ABOVE GROUND JUNCTION BOX
UNDERGROUND HANDHOLE
EMERGENCY BACK-UP LIGHT
EXIT SIGN WITH EMERGENCY LIGHT
SURGE PROTECTIVE DEVICE
FUSIBLE DISCONNECT
AIRCRAFT RATED HANDHOLE
AIR TRAFFIC CONTROL CENTER
BELOW FROST LINE
BARE STRANDED COPPER
CONDUIT
COMMUNICATION
EARTH ELECTRODE SYSTEM
EMERGENCY GENERATOR
ELECTRICAL METALLIC TUBING
FRAMEWORK
FEET
GOVERNMENT FURNISHED EQUIPMENT
GROUND FAULT CIRCUIT INTERRUPTER
GROUND CONDUCTOR
JUNCTION BOX
LOCALIZER
MAIN GROUND PLATE SUPPLEMENTAL
MAIN GROUND PLATE
MULTI-POINT GROUND PLATE
MANUAL TRANSFER SWITCH
NUMBER
POLYVINYL CHLORIDE
RADIO FREQUENCY
RIGID GALVANIZED STEEL CONDUIT
SCHEDULE
SERVICE ENTRANCE RATED
SURGE PROTECTIVE DEVICE
TYPICAL
AC HH
AWG
BSC
FRWK
MGP SUPP
MPG
MPGP
OR
15A
B120
REVISION
DEMOLITION
ROOM/AREA NUMBER
NORTH ARROW
ELEVATION REFERENCE
DETAIL TITLE REFERENCE
SECTION TITLE REFERENCE
CLOUD TO ENCOMPASS REVISED AREA
A012
A
E003
C
M023
B
M023
B
M023
D
S006
N
SECTION CUT
EXTENDED SECTION CUT
CIRCUIT BREAKER
GFCI RECEPTACLE
WP
FMC FLEXIBLE METALLIC CONDUIT
LFMC LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT
GGG-1400340-E008
GGG-1400340-E007
GGG-1400340-E006
GGG-1400340-E005
GGG-1400340-E004
GGG-1400340-E003
GGG-1400340-E002
GGG-1400340-E001
GGG-1400340-M024
GGG-1400340-M023
GGG-1400340-M022
GGG-1400340-M021
GGG-1400340-M020
GGG-1400340-M019
GGG-1400340-M018
GGG-1400340-M017
GGG-1400340-S008
GGG-1400340-S007
GGG-1400340-S006
GGG-1400340-A012
GGG-1400340-D012
GGG-1400340-D011
GGG-1400340-D010
GGG-1400340-D009
GGG-1400340-C002
GGG-1400340-G011
GGG-1400340-G010
GGG-1400340-G009
EAST WALL ELEVATION - ELECTRICAL
NEW PANELBOARD MDPN-1 AND MDPE-1 SCHEDULES
PARTIAL ELECTRICAL RISER DIAGRAM FOR HVAC EQUIPMENT 2
PARTIAL ELECTRICAL RISER DIAGRAM FOR HVAC EQUIPMENT 1 AND SCHEDULES
ENLARGED OUTDOOR ELECTRICAL PLAN CONDENSING UNITS
4TH AND 5TH FLOOR PLANS NEW WORK - ELECTRICAL
1ST, 2ND AND 3RD FLOOR PLANS NEW WORK - ELECTRICAL
GENERAL ELECTRICAL NOTES
EAST WALL ELEVATION - MECHANICAL
DETAILS - MECHANICAL
REFRIGERANT RISER DIAGRAM - MECHANICAL
SCHEDULES - MECHANICAL
ELEVATIONS PLANS NEW WORK - MECHANICAL
4TH, 5TH AND CAB FLOOR PLANS NEW WORK - MECHANICAL
1ST, 2ND AND 3RD FLOOR PLANS NEW WORK - MECHANICAL
GENERAL MECHANICAL NOTES
AHU HOUSEKEEPING PAD AND OUTDOOR CONDENSING UNIT PAD (CU)
3RD FLOOR AHU-3A OVERHEAD SUPPORT
GENERAL STRUCTURAL NOTES
ARCHITECTURAL NOTES AND DETAILS
DEMOLITION-ELECTRICAL ONE-LINE DIAGRAM
DEMOLITION-ELECTRICAL NOTES AND DEMOLITION ELECTRICAL SCHEDULE
DEMOLITION-MECHANICAL 4TH, 5TH AND CAB FLOOR PLANS
DEMOLITION-MECHANICAL 1ST, 2ND AND 3RD FLOOR PLANS
SITE LAYOUT PLAN
SYMBOLS AND ABBREVIATIONS - MECHANICAL
INDEX OF DRAWINGS, LEGEND, SYMBOLS AND ABBREVIATIONS - ELECTRICAL
COVER SHEET AND VICINITY MAP
INDEX OF DRAWINGS LEGEND
ELECTRICAL:
SYMBOLS ABBREVIATION
DRAWING TITLEDRAWING NO.
AMERICAN WIRE GAUGE
WEATHERPROOF
NOT ALL SYMBOLS AND ABBREVIATIONS MAY BE USED ON THIS PROJECT
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O R
TX
1400340
GGG-1400340-G010
ENGINEERING SERVICES
TERMINAL
ATCT
EAST TEXAS REGIONAL AIRPORTLONGVIEW
PROJECT ENGINEER MGR: ENGINEERING - FORT WORTH
THIS DRAWING PRODUCED ON ASW REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA
g -1
-g
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
2C11C TERMINAL DESIGN SUPPORT HVAC REPL
SYMBOLS AND ABBREVIATIONS ELECTRICAL
INDEX OF DRAWINGS, LEGEND,
FC
RDS
SR
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A C
T g -1
-d
.d g n
/1
/2
:1
:3
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
DEMOLITION NOTES - ELECTRICAL
EQUIPMENT ELECTRICAL SCHEDULE
EXISTING EQUIPMENT DEMOLITION
REFER TO DEMOLITION DRAWINGS D009, D010 AND MECHANICAL DRAWING M017.16.
REMOVE BRANCH CIRCUIT FOR OUTDOOR RECEPTACLE FED FROM PANEL NLP1, CIRCUIT NLP1-19.15.
- CONTROL WIRING DEMOLITION BY MECHANICAL CONTRACTOR.
MECHANICAL CONTRACTORS.
- DISCONNECT DUCT HEATERS ON BOTH ENDS, IN ELECTRICAL PANEL AND AT DUCT HEATER. DUCT HEATERS SHALL BE REMOVED BY
- REMOVE WIRING FROM PANEL TO INDOOR HVAC EQUIPMENT PER FAA DIRECTION. TYPICAL FOR ALL INDOOR HVAC UNITS.
TO CONDENSING UNIT.
- DISCONNECTS AND ASSOCIATED WIRING FOR CONDENSING UNITS (OUTDOOR) SHALL BE COMPLETELY REMOVED FROM DISCONNECT
EQUIPMENT DEMOLITION PER EXISTING EQUIPMENT DEMOLITION SCHEDULE.
DISCONNECT HVAC EQUIPMENT PER RESIDENT ENGINEER DIRECTION AND LOCK ASSOCIATED CIRCUIT BREAKER IN OFF POSITION.14.
CLEAN AND REPAIR EXISTING MATERIALS AND EQUIPMENT WHICH REMAIN OR ARE TO BE REUSED.13.
SHALL NOT BE REUSED UNLESS AUTHORIZED BY THE RESIDENT ENGINEER IN WRITING.
EQUIPMENT SPECIFIED OR INDICATED TO BE DEMOLISHED MUST BE REMOVED FROM THE PROJECT SITE AND12.
PANEL AS APPROPRIATE.
MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS11.
REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK.10.
DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT ARE REMOVED.9.
REMOVE EXPOSED ABANDONED CONDUIT.8.
NOTED ON CONTRACT DRAWINGS.
REMOVE ALL ABANDONED WIRING TO SOURCE OF SUPPLY. NO WIRING MAY BE ABANDONED IN-PLACE UNLESS OTHERWISE 7.
REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION.6.
AND CONFIRMATION 48 HOURS PRIOR TO DE-ENERGIZING THE PANEL.
WORK ON ENERGIZED CIRCUITS IS NOT ALLOWED. SCHEDULE AN OUTAGE AT LEAST 2 WEEKS BEFORE WORK IS REQUIRED5.
REQUIRED.
PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION, AS 4.
COORDINATE SERVICE OUTAGES WITH FAA THROUGH THE RESIDENT ENGINEER.3.
TO THE RESIDENT ENGINEER BEFORE DISTURBING THE EXISTING INSTALLATION.
DEMOLITION IS BASED ON LIMITED FIELD OBSERVATION AND DEMOLITION DOCUMENTS. SUBMIT DRAWINGS DISCREPANCIES 2.
VERIFY THAT FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS ARE AS SHOWN ON DRAWINGS.1.
UNIT PANEL CIRCUIT NUMBER CIRCUIT BREAKER/FUSE UNIT LOCATION
CU-3
CU-2
CU-1
MDPE
MDPE
ELP-3-2-B
1/3/5
14/16/18
5/7/9
OUTDOOR
OUTDOOR
OUTDOOR
100/3
100/3
15/3
AHU-7
AHU-6
AHU-5
AHU-4
AHU-3
AHU-2
CRU-1
AHU-1
ELPT
ELPT
NLPT
NLP5-4
ELP-3-2-B
ELP-3-2-B
TELCO
MDPN
21/23/25
14/16/18
14/16/18
9/11/13
24/26/28
23/25/27
8/10/12
1/3/5
70/3
70/3
50/3
50/3
70/3
50/3
40/3
125/3
5TH. FLOOR
5TH. FLOOR
5TH. FLOOR
4TH. FLOOR
3RD. FLOOR
3RD. FLOOR
2ND. FLOOR
2ND. FLOOR
AHU-7 DUCT HEATER
AHU-6 DUCT HEATER
AHU-5 DUCT HEATER
AHU-4 DUCT HEATER
AHU-1 DUCT HEATER
NLPT
NLPT
NLPT
NLP5-4
MDPN
13/15/17
20/22/24
19/21/23
9/11/13
1/3/5
40/3
40/3
40/3
40/3
100/3
5TH. FLOOR
5TH. FLOOR
5TH. FLOOR
4TH. FLOOR
2ND. FLOOR
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
RDS
SR 1400340
GGG-1400340-D011
2C11C TERMINAL DESIGN SUPPORT HVAC REPL
g -1
-d
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
DEMOLITION ELECTRICAL NOTES AND
FC
DEMOLITION EQUIPMENT ELECTRICAL SCHEDULE
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-d
.d g n
/1
/2
:2
:4
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
BATTERY RACK
CHARGER
BATTERY
WITH 3 NO.3/0 AND
1 NO.3 G
WITH 4 NO.3/0 AND 1 NO.3 G
2 SETS OF 2"C EACH
BANK
LOAD
2"C, 4 NO.1/0
AND 1 NO.6 G
12.4KV-120/208V,
3 PHASE, 4 WIRE
4-350 KCMIL AND 1 NO.1/0 G
(2) SETS OF 4"C EACH WITH
4-350 KCMIL AND 1 NO.1/0 G
(2) SETS OF 4"C EACH WITH
4 NO.3/0 AND 1 NO.3G
4 NO.3/0 AND 1 NO.3 G
2 SETS OF 2"C EACH WITH
REMOTE CONTROL
PANEL
ATS/BYPASS SWITCH
400 AMPS, 120/208V, 3-POLE
WITH OVERLAPPING NEUTRAL CIRCUIT BREAKER
E/G OUTPUT
4-WIRE, 60HZ, 0.8PF, DIESEL
100KW PRIME, 120/208V, 3-PHASE,
ENGINE GENERATOR
AND BATTERIES
ENGINE
CONTROL
2 SETS OF 2"C EACH
400A
3P
G
100 KW
PANEL
CONTROL
LOAD BANKNEMA 4
M
REMOTE
RADIATOR
E/G ROOM
PANEL
EGLP
225 KVA TRANSFORMER
WIREWAY
SURGE ARRESTER
MAIN SERVICE SWITCH
NORMAL POWER
600AS/600AF/3P
MDPN, 800A MLO, 120/208V, 3-PHASE, 4-WIRE
32/34/3631/33/3526/28/3025/2720/22/2419/21/2314/16/188/10/12 13/15/177/9/112/4/61/3/5
125A 50A 50A 70A 70A 70A 100A 100A 200A 175A 400A
3P
SPARE
3P 3P
SPARE
3P 3P 3P 3P 3P 2P 3P
SPARE
SPACE
3P
(2) SETS OF 2"C EACH WITH
AHU-6
HEATER
5TH FLOOR
AHU
NO.1
2ND FLOOR
MDPE, 400A MLO, 120/208V, 3-PHASE, 4-WIRE
26/28/3025/27/29
100A
3P3P
100A
19/21/2314/16/1813/15/178/10/12
100A
3P
100A
3P
100A
3P
70A
3P
ELEVATOR
SPARE
2/4/61/3/5
150A
3P
125A
3P
7/9/11
100A
3P
CU-3 CU-2
20/22/24
100A
3P
1 1
CRU-1
FLOOR)
(1 ST
NLP1
PANEL
BLDG
ADMIN
PANEL
FLOOR)
(5 TH
NLPT
PANEL
FLOOR)
(2 ND
2-A
NLPT
PANEL
FLOOR)
(4 TH
NLP5-4
PANEL
FLOOR)
(3 RD
NLP4-3
PANEL
(2) B
ELP-3
PANEL
FLOOR)
(2ND
EP-1
PANEL
FLOOR)
(5 TH
EP-3
PANEL
FLOOR)
(5 TH
ELPT
PANEL
FLOOR)
(3 RD
EP-2
PANEL
NOTES:
FLOOR)
(1 ST
ELP1
PANEL
FLOOR)
(1 ST
TELCO
= DEMOLITION
DEMOLITION ELECTRICAL ONE-LINE DIAGRAM **
NOT TO SCALE
D012
**ONE-LINE DIAGRAM
SEE D011 FOR ADDITIONAL EQUIPMENT DEMOLITION SCHEDULE.
(EXISTING DRAWING NOTES DELETED)
= FAA DRAWING GGG-EGR-E01, DATED 06/09/05
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
1400340
GGG-1400340-D012
DEMOLITION ELECTRICAL
g -1
-d
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
FC
RDS
SR
ONE-LINE DIAGRAM
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-e
.d g n
/1
/2
:3
:0
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
FAA "LOCKOUT/TAGOUT" PROCEDURE FORM
NOT TO SCALE
GENERAL ELECTRICAL NOTES:
MAINTAIN A SET OF DRAWINGS IN THE FIELD WITH AS-BUILT MARKINGS.25.
SUBCONTRACTOR SHALL ALSO REVIEW THE MECHANICAL DRAWINGS FOR NOTES.24.
FOR THIS PROJECT. TEMPORARY INSTALLATION TO COMPLY WITH ART 590 OF THE NEC.
FURNISH AND INSTALL TEMPORARY WIRING FROM EXISTING DISCONNECTS TO TEMPORARY HVAC UNITS AS REQUIRED23.
WITH PAINT OR THE APPROPRIATE COATING TO PREVENT CORROSION.
REMOVE PAINT FROM THE AREA THAT GROUND LUGS ARE TO BE INSTALLED. AFTER INSTALLATION SEAL THE AREA22.
BOND ALL OUTDOOR HVAC EQUIPMENT ENCLOSURES TO EES. UNDERGROUND CONNECTION TO BE EXOTHERMIC WELD.21.
FAA-STD-019 LATEST EDITION.
METAL PARTS, CONDUITS, EQUIPMENT, AND JUNCTION BOXES ARE TO BE GROUNDED IN ACCORDANCE WITH20.
COPPER CONDUCTOR TO THE ENCLOSURE.
ALL RGS CONDUITS ENTERING A J-BOX OR SHELTER SHALL BE BONDED WITH A NO.2 AWG BARE-STRANDED19.
ALL CONNECTIONS TO THE EES SHALL BE EXOTHERMICALLY WELDED PER FAA-STD-019 LATEST EDITION.18.
CONTRACTOR.
CONTROL WIRING CONDUIT, JUNCTION BOXES AND TERMINATIONS FOR MECHANICAL EQUIPMENT, BY MECHANICAL17.
THREADED RGS CONDUITS. CONDUIT ENTRIES SHALL BE WATERTIGHT.
ALL EXTERIOR CONDUIT TERMINATIONS TO ENCLOSURE SHALL USE GASKETED MYERS TYPE HUB ASSEMBLIES FOR16.
TYPED AND INSTALLED INSIDE PANEL.
UPDATE PANEL SCHEDULES TO REFLECT CHANGES UNDER THIS CONTRACT. NEW PANELBOARD SCHEDULE MUST BE15.
"ON" AND "OFF" POSITION.
ALL DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE. DISCONNECT SHALL BE CAPABLE OF BEING LOCKED IN THE14.
AND 5 AM. FOR EXACT TIME COORDINATE WITH FAA.
ALL ELECTRICAL CONNECTION TO THE PANELS OR HVAC EQUIPMENT SHALL BE DONE BETWEEN THE HOUR OF 11 PM13.
ALL NEW CIRCUIT BREAKERS FOR HVAC EQUIPMENT TO BE "HACR" TYPE. SAME MANUFACTURER AS EXISTING.12.
MANUFACTURER OR NOTED ON THE DRAWINGS. SEE FAA "LOCKOUT/TAGOUT" PROCEDURE FORM.
STRANDED. CONTROL WIRE SHALL BE SIZED, AT MINIMUM, NO.14 AWG UNLESS OTHERWISE REQUIRED BY
SIZED NO.12 AWG AND SMALLER, FOR GENERAL USE, SHALL BE SOLID. CONDUCTORS NO.10 AWG AND LARGER MAY BE
ALL CONDUCTORS SHALL BE COPPER. MINIMUM BRANCH CIRCUIT CONDUCTOR SIZE SHALL BE NO.12 AWG. CONDUCTORS11.
A MINIMUM OF 72 HOURS ADVANCE NOTICE. SEE FAA LOTO FORM.
PROCEDURES PRIOR TO EACH ELECTRICAL OUTAGE. OUTAGES SHALL BE COORDINATED WITH FAA AND REQUIRE
LOCKOUT/TAG OUT PROCEDURES SHALL BE STRICTLY ENFORCED THROUGHOUT THIS PROJECT. REVIEW THESE10.
NEUTRALS ARE NOT ALLOWED.
EACH CIRCUIT SHALL MAINTAIN AN INDIVIDUAL NEUTRAL AND EQUIPMENT GROUND CONDUCTOR. SHARED9.
AFTER INSTALLATION, CONDUCTORS SHALL BE TESTED IN ACCORDANCE WITH SPECIFICATION SECTION 26 05 19.8.
COMPLETE THE SERVICE FOR EACH PIECE OF EQUIPMENT INSTALLED UNDER THE CONTRACT.
SUBCONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUITS, JUNCTION BOXES, CABLES, TERMINATORS, ETC TO7.
ALL NEW EQUIPMENT MUST BE MARKED WITH THE APPROPRIATE ARC FLASH LABELS PER NFPA 70E LATEST EDITION.6.
REQUIREMENT OF THE NFPA 70 LATEST EDITION.
ALL NEW INSTALLED ELECTRICAL EQUIPMENT SHALL COMPLY WITH THE WORKING SPACE DEPTH AND WIDTH.5.
OTHER PIPING OR DUCTWORK.
ALL CONDUITS SHALL BE SUPPORTED FROM STRUCTURE ONLY. NO CONDUITS SHALL BE SUPPORTED FROM4.
RGS CONDUIT FITTINGS SHALL BE THREADED TYPE ONLY. EMT FITTINGS SHALL BE COMPRESSION TYPE ONLY.
FOR INDOOR APPLICATION AND LIQUID TIGHT FLEXIBLE METAL CONDUIT (LFMC) FOR OUTDOOR APPLICATION.
PERMITTED RACEWAY TYPES ARE EMT, PVC SCH 80, RGSC, PVC COATED RGSC, FLEXIBLE METAL CONDUIT (FMC)3.
EXTERIOR ENCLOSURES, MUST BE NEMA 4X-SS316 RATED. MOUNTING HARDWARE SHALL BE CORROSION RESISTANT. 2.
NFPA 70, LATEST EDITION.
AND DRAWINGS. ALL ELECTRICAL WORK SHALL COMPLY WITH FAA-STD-019, AND FAA-C-1217, FAA-C-1391, AND
ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH DIVISION-26 OF THE CONTRACT SPECIFICATIONS1.
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
FC
RDS
GGG-1400340-E001
GENERAL ELECTRICAL NOTES
g -1
-e
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-e
.d g n
/1
/2
:4
:5
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
ELPT
PANEL
EXIST.
AHU-5B
TO MDPE
AHU-5CAHU-5ANLPT
PANEL
EXIST
5TH FLOOR
TO MDPN
AHU-4NLP-5-4
PANEL
EXIST.
4TH FLOOR
TO MDPN
3RD FLOOR
AHU-3A AHU-3B
TO MDPN
NLP-3-2-A
PANEL
EXIST.
2ND FLOOR
TO MDPN
AHU-2A AHU-2B
TO MDPE
ELP-3-2B
PANEL
EXIST.
TO UTILITY
600A
SWITCH
EXISTING AHU-1
MDPN
EXIST.
ATS
EXIST.
FLOOR
GROUND
MDPE
EXIST.
FOR CONTINUATION
SEE E006
PARTIAL RISER DIAGRAM
NOT TO SCALE
003003
SPD
TYPICAL
SEE NOTE 9,
TO MDPN-1
125KVA
EG
EXIST.
150KVA
007 006
GENERAL NOTES:
NLP-4-3
PANEL
EXIST.
TRANSFORMER
EXIST. UTILITY
INDOOR UNIT
MOCPD
60/3
60/3
60/3
60/3
60/3
60/3
60/3
60/3
60/3
DISCONNECT N1
AHU INDOOR SCHEDULE
UNIT TONAGE CIRCUIT
NLPT, 21/23/25
ELPT, 14/16/18
NLPT, 14/16/18
NLP-5-4, 9/11/13
ELP-3-2-8, 24/26/28
NLP4-3, 26/28/30
ELP-3-2-B, 23/25/27
NLP-3-2-A, 14/16/18
MDPN-1, 19/21/23
TAG
(4) #250KCMIL, #4 GND
4#1/0, #6 GND
4#2, #6 GND
3#6, #10 GND
3#8, #10 GND
3#10, #10 GND
3#12, #12 GND
CONDUCTOR SIZE
2 1/2"
2"
1"
1"
3/4"
3/4"
3/4"
CONDUIT SIZE
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
CONDUIT TYPE
CONDUCTOR* AND CONDUIT SCHEDULE
AHU-5C
AHU-5B
AHU-5A
AHU-4
AHU-3B
AHU-3A
AHU-2B
AHU-2A
AHU-1
34.9
39.6
39.6
34.9
39.6
39.6
34.9
34.9
34.9
MCA
PHONE: (903) 657-4571, FAX: (903) 657-5377
UTILITY COMPANY: RUSK COUNTY ELECTRIC COOPERATIVE16.
- MDPE - CB"A", TQD 150A
- MDPN - 26/28/30, TJK 250A
PROVIDE NEW CIRCUIT BREAKERS FOR PANELS:15.
DESIGN BASE CARRIER EQUIPMENT.14.
PHENOLIC LABELS, SEE DETAIL 1 ON E007.13.
MDPE - 9,417A/3P
MDPN - 13,463A/3P
MAXIMUM FAULT CURRENT:12.
NEW PANELS MDPN-1, AND MDPE-1. SEE SCHEDULE E007.11.
SEE DRAWINGS E002 AND E003 FOR DISCONNECT LOCATIONS.10.
REFER TO HVAC DRAWINGS FOR SEQUENCE OF OPERATION AND OTHER DETAILS.9.
FINAL CONNECTION FOR INDOOR AHU’S, FLEXIBLE METAL CONDUIT.8.
AND NEMA 1 ENCLOSURE.
DISCONNECT ARE WALL MOUNTED. ALL DISCONNECTS ARE HEAVY-DUTY (HD) TYPE7.
CONNECTION.
10 KW HEATERS ARE FACTORY PROVIDED WITHIN AHU’S, AHU’S - SINGLE POINT6.
EXISTING PANEL.
PANELS. NEW CIRCUIT BREAKERS TO BE SAME TYPE AS OTHER BREAKER IN
AS REQUIRED, PROVIDE NEW CIRCUIT BREAKERS AND INSTALL THEM IN EXISTING 5.
OF EQUIPMENT AND FINAL CONNECTION TO THE EQUIPMENT.
PROVIDE NEW CONDUIT AND WIRE FROM EXISTING PANELS TO THE DISCONNECTS 4.
NEW HVAC ELECTRICAL LOAD IS APPROXIMATELY EQUAL TO THE EXISTING HVAC. 3.
3 PHASES.
EXISTING EMERGENCY GENERATOR IS RATED 100 KW 125 KVA AT 208/120V, 2.
EXISTING ELECTRICAL SERVICE IS RATED 600 AMPS AT 208/120V, 3 PHASE.1.
*INDOOR APPLICATION, THHN INSULATION
SEE NOTE 15
NEW CIRCUIT BREAKERS
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
EG
GGG-1400340-E005
g -1
-e
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
HVAC EQUIPMENT 1 AND SCHEDULES
PARTIAL ELECTRICAL RISER DIAGRAM FOR
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-e
.d g n
/1
/2
:5
:1
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
CU-5BCU-3BCU-2B
CU-2A CU-3A CU-1 CU-5C CU-4 CU-5A
SPD
002007 003 002 003002
SPD
002 003 003006
INDOOR OUTDOOR
PARTIAL RISER DIAGRAM - NORMAL POWER FOR HVAC
NOT TO SCALE
PARTIAL RISER DIAGRAM - ESSENTIAL POWER FOR HVAC
NOT TO SCALE
225A
MDPN-1
FINISH GRADE
FINISH GRADE
OUTDOORINDOOR
GROUND FLOOR
GROUND FLOOR
150A
MDPE-1
CONTINUATION
SEE E005 FOR
TO MDPE
DISCONNECT
TO AHU-1
CONTINUATION
SEE E005 FOR
GENERAL NOTES:
OUTDOOR OUTDOOR UNIT
"CU" OUTDOOR SCHEDULE
CU-5C
CU-5B
CU-5A
CU-4
CU-3B
CU-3A
CU-2B
CU-2A
CU-1
UNIT
TONAGE
MCA
MOCPD
TAG
(4) #250KCMIL, #4 GND
4#1/0, #6 GND
4#2, #6 GND
3#6, #10 GND
3#8, #10 GND
3#10, #10 GND
3#12, #12 GND
CONDUCTOR SIZE
2 1/2"
2"
1"
1"
3/4"
3/4"
3/4"
CONDUIT SIZE
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
RGS/LFMC
CONDUIT TYPE
30/3
30/3
30/3
60/3
60/3
30/3
60/3
60/3
30/3
NEMA 4X-SS316
DISCONNECT
CONDUCTOR* AND CONDUIT SCHEDULE
*OUTDOOR APPLICATION, THWN-2 INSULATION
DESIGN BASED ON CARRIER EQUIPMENT.16.
PHENOLIC LABELS, SEE NOTE 1 ON E007.15.
SAFETY DISCONNECT SWITCHES FOR ALL OUTDOOR UNITS SHALL BE TYPE: NEMA4X SS31614.
SEE DRAWING E004 FOR EXACT LOCATION OF CONDENSING UNITS.13.
REFER TO HVAC DRAWINGS FOR SEQUENCE OF OPERATION AND OTHER DETAILS.12.
WITHOUT SHARP BENDS.
SPD SHALL BE INSTALLED WITH MINIMUM LENGTH OF CONDUCTORS AND11.
FOR NEW PANELS.
PROVIDE SURGE PROTECTION DEVICE (SPD) MODEL #120-3Y-M3-4-06-A-H. BY RAYCAP10.
FOR LOCATION OF PANELS MDPN-1 AND MDPE-1, SEE E002.9.
AND NEMA 4X-SS316 ENCLOSURE. FINAL CONNECTION TO CONDENSING UNIT LFMC.
DISCONNECT ARE RACK MOUNTED. ALL DISCONNECTS ARE HEAVY-DUTY (HD) TYPE8.
PROVIDE NEW PANELS MDPE-1, AND MDPN-1 TO FEED CONDENSING UNITS.7.
NOT USED.6.
NOT USED.5.
OF EQUIPMENT AND FINAL CONNECTION TO THE EQUIPMENT.
PROVIDE NEW CONDUIT AND WIRE FROM EXISTING PANELS TO THE DISCONNECTS 4.
NEW HVAC ELECTRICAL LOAD IS APPROXIMATELY EQUAL TO THE EXISTING HVAC. 3.
3 PHASES.
EXISTING EMERGENCY GENERATOR IS RATED 100 KW 125 KVA AT 208/120V, 2.
EXISTING ELECTRICAL SERVICE IS RATED 600 AMPS AT 208/120V, 3 PHASE.1.
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
EG
GGG-1400340-E006
FOR HVAC EQUIPMENT 2
PARTIAL ELECTRICAL RISER DIAGRAM
g -1
-e
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-e
.d g n
/1
/2
:5
:2
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
PHENOLIC LABELS
NOT TO SCALE
E007
FED FROM: MDPN-26/28/30
120/208V, 3PH
250A MCB
MDPN-1
FED FROM: MDPE-CB"A"
120/208V, 3PH
150A MCB
MDPE-1
DESCRIPTION
CU-2A
AHU-1
SPACE
SPACE
PANEL SCHEDULE: MDPN-1 (NEW), 3PH-4W
VOLTAGE: 120/208V
MOUNTING: SURFACE
BUS RATING: 250A
ENCLOSURE: NEMA 1
SCR 18,000 AMPS SYM (MINIMUM)
LOCATION: 1ST. FLOOR MECHANICAL RM.
MAIN CIRC. BKR: 250A*
CU-1
CU-3A
SPACE
BREAKER
AMP POLE
30*
30*
50*
35*
SUBTOTALS
LCL
VOLT AMPS
A B C
VOLT AMPS
CBA
BA C
124681246812468 9200 9200 9200
LCL
BREAKER
POLEAMP
30* 3
350*
330*
100 3
DESCRIPTION
CU-4
CU-5A
CU-5C
SPACE
SPACE
SPACE
SPD (RAYCAP)
TOTAL PHASE B= 21668
TOTAL PHASE C= 21668
TOTAL PHASE A= 21668
3150L. C. L. LOAD X 0.25 *HACR CIRCUIT BREAKER
TOTAL CONN LOAD= 65004
CONNECTED HVAC LOAD 65004
12600L. C. L. LOAD=
68154TOTAL LOAD= 189.32DESIGN AMPS:
NO
CKT
NO
CKT
PANELBOARD SCHEDULE MDPN-1
DESCRIPTION
CU-3B
SPACE
SPACE
PANEL SCHEDULE: MDPE-1 (NEW), 3PH-4W
VOLTAGE: 120/208V
MOUNTING: SURFACE
BUS RATING: 225A
ENCLOSURE: NEMA 1 LOCATION: 1ST. FLOOR MECHANICAL RM.
MAIN CIRC. BKR: 150A*
SPACE
BREAKER
AMP POLE
30*
50*
SUBTOTALS
LCL
VOLT AMPS
A B C
VOLT AMPS
CBA
BA C
4280 4280 4280
LCL
BREAKER
POLEAMP
50* 3
100 3
DESCRIPTION
SPACE
SPACE
SPACE
SPD (RAYCAP)
TOTAL PHASE B= 10940
TOTAL PHASE C= 10940
TOTAL PHASE A= 10940
3150L. C. L. LOAD X 0.25 *HACR CIRCUIT BREAKER
TOTAL CONN LOAD= 32820
CONNECTED HVAC LOAD 32820
12600L. C. L. LOAD=
35970TOTAL LOAD= 99.92DESIGN AMPS:
NO
CKT
NO
CKT
PANELBOARD SCHEDULE MDPE-1
CU-2B
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
6660 6660 6660
CU-5B
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
GENERAL NOTES:
OR RIVETS. SEE DETAIL 1/E007 FOR LABEL WORDING.
LABELS PER SPECIFICATION. FASTEN LABELS WITH STAINLESS MACHINE SCREWS
ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT SHALL INCLUDE PHENOLIC3.
CIRCUIT CURRENT AT THEIR TERMINALS.
INDIVIDUAL INTERRUPTING EQUAL TO OR GREATER THAN AVAILABLE SHORT-
CIRCUIT BREAKERS SHALL BE "FULL RATED". ALL CIRCUIT BREAKERS HAVE AN2.
PANELBOARD SHALL HAVE COPPER BUS.1.
SCR 14,000 AMPS SYM (MINIMUM)
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
E D
M
IS
S
U E
D F
O
EG
GGG-1400340-E007
g -1
-e
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
MDPN-1 AND MDPE-1 SCHEDULES
NEW PANELBOARD
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A g -1
-e
.d g n
/1
/2
:5
:0
A
M E a rl D -C
T R G a rc ia
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
WIREWAY SECTION
NOT TO SCALE
FINISHED FLOOR
FINISHED GRADE
TO DISCONNECTS
CONDUITS
WIREWAY NEMA 4X
8"x8"x2’-0"
WIREWAY NEMA 1
8"x8"x2’-0"
EAST WALL
3/4" RGSC (TYP)
EAST WALL ELEVATION - ELECTRICAL
NOT TO SCALE
TRENCH REQUIREMENTS DETAIL
NOT TO SCALE
E008 (JOINT USE ELECTRICAL AND REFRIGERATION)
FINISH GRADE
1’-0"
CONCRETE
BACKFILL
TAMPERED
CONDUITS
ELECTRICAL
EXISTING WINDOW
CU-1
D
CU-4
CU-5B
FINISHED GRADE
EXISTING LOUVERED PANEL
EXISTING BUILDING EAST WALL
CU-5C
DDD
EXISTING GROUND LOOP
CU-5A
D
CU-3B
D
CU-3A
D
CU-2B
D
CU-2A
D
DISCONNECT (TYP)
RACK MOUNTED NEMA 4X-SS
PVC COATED RGSC 3/4" (TYP)
SEE DETAIL BELOW
NEMA 4X
8"x8"x2’-0" WIREWAY
2-1/2" RGSC
BARE CONDUCTOR (TYP OF 2)
3/4" PVC SCH 80 CONDUIT WITH NO.2 AWG
SEE MECHANICAL DRAWINGS
WALL PENETRATION
(TYP)
LFMC
BEDDING
MECHANICAL PIPING
1-1/2" RGSC
SEE DETAIL BELOW
NEMA 4X
8"x8"x1’-0" WIREWAY
E D
M
IS
S
U E
D
F O
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
SM
GGG-1400340-E008
g -1
-e
.d g n
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
RELEASED FOR:
CONSTRUCTION, OR BIDDING
NOT TO BE USED FOR PERMITTING,
Firm Registration #15376
817.834.2165 (Fax)
817.759.4820
Fort Worth, Tx. 76137
Suite 228
4500 Mercantile Plaza Dr.
PTSI Managed Services Inc.
FOR REVIEW PURPOSES ONLY
FINAL SUBMITTAL 12/21/2020
S A
F E
T Y
Q
U A
L
IT
Y
INTEGRITY
IN
N
O V
A T I
O N
T E
C H
N I C
A
L S
U P
PORT SERVIC
E
S C
O N
T R
A C
T
EAST WALL ELEVATION - ELECTRICAL
| ggg-1400340-g009 |
| ggg-1400340-g010 |
| ggg-1400340-g011 |
| ggg-1400340-c002 |
| ggg-1400340-d009 |
| ggg-1400340-d010 |
| ggg-1400340-d011 |
| ggg-1400340-d012 |
| ARCHITECTURAL DWG_ASW 2791 GGG - CORRECTED_ATCT 100 |
| Sheets and Views |
| Layout1 |
| preview |
| ggg-1400340-s006 |
| ggg-1400340-s007 |
| ggg-1400340-s008 |
| ggg-1400340-m017 |
| ggg-1400340-m018 |
| ggg-1400340-m019 |
| ggg-1400340-m020 |
| ggg-1400340-m021 |
| ggg-1400340-m022 |
| ggg-1400340-m023 |
| ggg-1400340-m024 |
| ggg-1400340-e001 |
| ggg-1400340-e002 |
| ggg-1400340-e003 |
| ggg-1400340-e004 |
| ggg-1400340-e005 |
| ggg-1400340-e006 |
| ggg-1400340-e007 |
| ggg-1400340-e008 |
File details come from the government source that posted it. Updated .