Generator and Building layout Byron.pdf
PDF 229 KB Posted
- Attached to
- EMA - Byron GEMS Backup Generator - ARG
- Solicitation number
- 23-588IEMA-MGMTA-B-32331
- Issued by
- Morgan County, Illinois
About this file
The provided document is a layout plan for a diesel generator and above ground storage tank replacement project at the Byron Generating Station in Illinois. The Illinois Emergency Management Agency (IEMA) is seeking a vendor to remove an old backup generator and replace it with a new backup generator with an integrated above ground storage tank. The project involves extending the existing generator pad and installing new conduits and lines. This contract opportunity covers the state of Illinois, specifically Ogle County.
The document does not include details on pricing terms, set asides, incumbents, funding requirements, or other salient commercial information. It focuses solely on the technical layout and specifications for the generator and storage tank replacement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Prevailing Wage~5.docx | DOCX document | |
| Standard Terms and Conditions v.23.1~3.pdf | ||
| Standard Certifications V.18.1~3.docx | DOCX document | |
| Byron Generator Replacement Scope of Work.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DG Day Tank
Existing Diesel
Generator Cabinet
ABOVE GROUND
STORAGE TANK
Diesel Generator Cabinet
Generator Pad
Extension
Existing Generator
Pad
Existing Diesel Generator
Pad is about 8" thick plus 8" below ground
Division Of Nuclear Safety 1035 Outer Park Drive Springfield, IL 62704
Illinois Emergency Management Agency
AutoCAD SHX Text
IEMA GEMS BUILDING
AutoCAD SHX Text
DAY TANK LINES
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
EXISTING GENERATOR PAD
AutoCAD SHX Text
GEN PAD EXTENSION
AutoCAD SHX Text
UST
AutoCAD SHX Text Conduits
AutoCAD SHX Text
UST VENT
AutoCAD SHX Text
FENCE
AutoCAD SHX Text
GATE
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
CCR #
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CCR #
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CCR #
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TECHNICAL DOCUMENT
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGN BY
AutoCAD SHX Text
NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
GR-BY-01 REV. B
AutoCAD SHX Text
DIESEL GENERATOR WITH AST REPLACEMENT
AutoCAD SHX Text
GASEOUS EFFLUENT MONITORING SYSTEM
AutoCAD SHX Text
BYRON, ILLINOIS
AutoCAD SHX Text T. Hendrickson
AutoCAD SHX Text 7-25-2022
AutoCAD SHX Text A
AutoCAD SHX Text T. Hendrickson
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
| Sheets and Views |
| Generator and Building layout Byron-Layout2 |
File details come from the government source that posted it. Updated .