Generator addendum No.1 attachment.pdf
PDF 727 KB Posted
- Solicitation number
- 20230229
- Issued by
- Berrien County, Sterling Heights City, Michigan
About this file
This document is a construction site plan for the City of South Lyon's Wastewater Treatment Plant New Generator Installation Project, prepared by HRC Engineering. The plan details the site layout for installing a new generator, showing the precise location, concrete foundation, and surrounding infrastructure at the wastewater treatment facility. The site plan includes existing utility lines, green space areas, maintenance buildings, and specifies the new generator's placement relative to current site structures. The drawing provides a comprehensive view of the generator installation, including grading, utility connections, and spatial relationships with existing facilities.
The site plan indicates careful consideration of site conditions, with notes about excavation, concrete work, and utility coordination. The plan includes an existing legend showing current site features like fencing, water lines, electrical lines, and communication infrastructure. The drawing is scaled at 1"=10'-0" and dated July 2024, suggesting an upcoming project implementation. A call-before-you-dig notice is prominently displayed, emphasizing the importance of utility protection during construction. The plan appears to be part of a detailed engineering document set for the generator installation project, providing technical guidance for contractors and project managers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Generator addendum No.1.pdf | ||
| specs for new generator project.pdf | ||
| WWTP new generator project.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPROVED
CHECKED
DRAWN
DESIGNED
DATE
HRC JOB NO.
DATE
SCALE
ADDITIONS AND/OR REVISIONS
SHEET
NO.
OF
555 HULET DRIVE
BLOOMFIELD HILLS, MICH.
P.O. BOX 824
48303 - 0824
PHONE: (248) 454-6300
WEB SITE: www.hrcengr.com
FAX (1st. Floor): (248) 454-6312 FAX (2nd. Floor): (248) 454-6359
CITY OF SOUTH LYON
WASTE WATER
TREATMENT PLANT
NEW GENERATOR
INSTALLATION
PROJECT
72 HOURS
BEFORE YOU DIG
(3 WORKING DAYS)
CALL MISS DIG
1-800-482-7171 (TOLL FREE)CALL811.COM or 811
Know what's below.
Call before you dig.
N
AutoCAD SHX Text
GM
AutoCAD SHX Text T
AutoCAD SHX Text
PRIMARY SWITCH + METER
AutoCAD SHX Text
SA
AutoCAD SHX Text
SA
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
UN
AutoCAD SHX Text 2023 Hubbell, Roth & Clark, Inc. All Rights Reserved
AutoCAD SHX Text C
AutoCAD SHX Text V:\202302\20230229\C\Sheets\C-3.dwg
AutoCAD SHX Text Uhlianuk, Adam
AutoCAD SHX Text
AutoCAD SHX Text
7/30/2024 4:21 PM
AutoCAD SHX Text 20230229
AutoCAD SHX Text July 2024
AutoCAD SHX Text
ORIGINAL PLOT SIZE: ANSI FULL BLEED D (34.00 X 22.00 INCHES)
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
SITE PLAN SHEET
AutoCAD SHX Text 1"=10'-0"
AutoCAD SHX Text C-3
AutoCAD SHX Text A.R.U.
AutoCAD SHX Text A.R.U.
AutoCAD SHX Text M.J.R.
AutoCAD SHX Text R.N.A.
AutoCAD SHX Text 05-24-24
AutoCAD SHX Text
FOR CITY REVIEW
AutoCAD SHX Text 07-12-24
AutoCAD SHX Text
ISSUED FOR BIDS
AutoCAD SHX Text 07-30-24
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text
SCALE: 1" = 10'-0"
AutoCAD SHX Text
AutoCAD SHX Text 2.5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTE: ALL EXISTING UTILITIES SHOWN ON THIS TOPOGRAPHIC SURVEY HAVE BEEN TAKEN FROM VISUAL OBSERVATION AND RECORD MAPPING WHERE AVAILABLE. NO GUARANTEE IS MADE, OR SHOULD BE ASSUMED. AS TO THE COMPLETENESS OR ACCURACY OF THE UTILITIES SHOWN ON THIS DRAWING. PARTIES UTILIZING THIS INFORMATION SHALL FIELD VERIFY. PRIOR TO CONSTRUCTION ALL LOCATIONS AND DEPTHS OR EXISTING UTILITIES (IN CONFLICT WITH PROPOSED IMPROVEMENTS) SHALL BE VERIFIED IN THE FIELD. CALL MISS DIG 3 WORKING DAYS PRIOR TO CONSTRUCTION.
AutoCAD SHX Text
STORAGE BUILDING
AutoCAD SHX Text
ABANDONED PRIMARY TANKS
AutoCAD SHX Text
CONTROL BUILDING
AutoCAD SHX Text
SCREENING ROOM
AutoCAD SHX Text
HYD.
AutoCAD SHX Text
EX. 6" WTR.MAIN
AutoCAD SHX Text
EX. 12" WTR.MAIN
AutoCAD SHX Text
12" WTR.MAIN
AutoCAD SHX Text
EX. 12" WTR.MAIN
AutoCAD SHX Text
EX. 27" SAN.
AutoCAD SHX Text
EX. 30" SAN.
AutoCAD SHX Text
EX. N.G. LINE
AutoCAD SHX Text
GENERATOR STRUCTURAL FOUNDATION PAD
AutoCAD SHX Text
MAINTENANCE STRIP CONCRETE, 6" NON-REINFORCED
AutoCAD SHX Text
EX. CONC. S.W.
AutoCAD SHX Text
EXISTING LEGEND
AutoCAD SHX Text EXISTING FENCE EXISTING SANITARY SEWER LINE EXISTING FIRE MAIN WATER LINE EXISTING STORM SEWER LINE EXISTING STEAM CONDENSATE LINE EXISTING ELECTRICAL SITE POWER EXISTING GAS MAIN LINE EXISTING WATER MAIN LINE EXISTING COLD DOMESTIC WATER EXISTING COMMUNICATIONS LINE EXISTING PIV EXISTING WATER HYDRANT EXISTING LIGHT POLE EXISTING STORM CATCH BASINS EXISTING SANITARY MANHOLE EXISTING GATE VALVE
AutoCAD SHX Text
PIV
AutoCAD SHX Text
SA
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
GARAGE AREA/ STORAGE
AutoCAD SHX Text
NEW HMA PAVEMENT PATCHING
AutoCAD SHX Text
GREEN SPACE RESTORATION AREA
AutoCAD SHX Text NOTE: A. CONTRACTOR MAY DIRECTIONAL BORE CONDUITS TO GREEN CONTRACTOR MAY DIRECTIONAL BORE CONDUITS TO GREEN SPACE AND OMIT HMA PAVING REQUIREMENTS. EXISTING DRIVEWAY IS BLOCK CRACKING WHICH MAY CAUSE EXTENDED REPAIRS IF OPENED FOR TRENCHING. USE OF HAND PATCH SHALL BE USED TO REPAIR SMALL DAMAGED AREAS AS REQUIRED.
AutoCAD SHX Text
1.5% MAX
AutoCAD SHX Text
| Sheets and Views |
| Cover |