Generator addendum No.1 attachment.pdf

PDF 727 KB Posted

Attached to
Wastewater Treatment Plant New Generator Installation
Solicitation number
20230229
Issued by
Berrien County, Sterling Heights City, Michigan

About this file

This document is a construction site plan for the City of South Lyon's Wastewater Treatment Plant New Generator Installation Project, prepared by HRC Engineering. The plan details the site layout for installing a new generator, showing the precise location, concrete foundation, and surrounding infrastructure at the wastewater treatment facility. The site plan includes existing utility lines, green space areas, maintenance buildings, and specifies the new generator's placement relative to current site structures. The drawing provides a comprehensive view of the generator installation, including grading, utility connections, and spatial relationships with existing facilities.

The site plan indicates careful consideration of site conditions, with notes about excavation, concrete work, and utility coordination. The plan includes an existing legend showing current site features like fencing, water lines, electrical lines, and communication infrastructure. The drawing is scaled at 1"=10'-0" and dated July 2024, suggesting an upcoming project implementation. A call-before-you-dig notice is prominently displayed, emphasizing the importance of utility protection during construction. The plan appears to be part of a detailed engineering document set for the generator installation project, providing technical guidance for contractors and project managers.

View the file

Other files

File Type Posted
Generator addendum No.1.pdf PDF
specs for new generator project.pdf PDF
WWTP new generator project.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPROVED

CHECKED

DRAWN

DESIGNED

DATE

HRC JOB NO.

DATE

SCALE

ADDITIONS AND/OR REVISIONS

SHEET

NO.

OF

555 HULET DRIVE

BLOOMFIELD HILLS, MICH.

P.O. BOX 824

48303 - 0824

PHONE: (248) 454-6300

WEB SITE: www.hrcengr.com

FAX (1st. Floor): (248) 454-6312 FAX (2nd. Floor): (248) 454-6359

CITY OF SOUTH LYON

WASTE WATER

TREATMENT PLANT

NEW GENERATOR

INSTALLATION

PROJECT

72 HOURS

BEFORE YOU DIG

(3 WORKING DAYS)

CALL MISS DIG

1-800-482-7171 (TOLL FREE)CALL811.COM or 811

Know what's below.

Call before you dig.

N

AutoCAD SHX Text

GM

AutoCAD SHX Text T

AutoCAD SHX Text

PRIMARY SWITCH + METER

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

UN

AutoCAD SHX Text 2023 Hubbell, Roth & Clark, Inc. All Rights Reserved

AutoCAD SHX Text C

AutoCAD SHX Text V:\202302\20230229\C\Sheets\C-3.dwg

AutoCAD SHX Text Uhlianuk, Adam

AutoCAD SHX Text

AutoCAD SHX Text

7/30/2024 4:21 PM

AutoCAD SHX Text 20230229

AutoCAD SHX Text July 2024

AutoCAD SHX Text

ORIGINAL PLOT SIZE: ANSI FULL BLEED D (34.00 X 22.00 INCHES)

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

SITE PLAN SHEET

AutoCAD SHX Text 1"=10'-0"

AutoCAD SHX Text C-3

AutoCAD SHX Text A.R.U.

AutoCAD SHX Text A.R.U.

AutoCAD SHX Text M.J.R.

AutoCAD SHX Text R.N.A.

AutoCAD SHX Text 05-24-24

AutoCAD SHX Text

FOR CITY REVIEW

AutoCAD SHX Text 07-12-24

AutoCAD SHX Text

ISSUED FOR BIDS

AutoCAD SHX Text 07-30-24

AutoCAD SHX Text

ADDENDUM 1

AutoCAD SHX Text

SCALE: 1" = 10'-0"

AutoCAD SHX Text

AutoCAD SHX Text 2.5

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: ALL EXISTING UTILITIES SHOWN ON THIS TOPOGRAPHIC SURVEY HAVE BEEN TAKEN FROM VISUAL OBSERVATION AND RECORD MAPPING WHERE AVAILABLE. NO GUARANTEE IS MADE, OR SHOULD BE ASSUMED. AS TO THE COMPLETENESS OR ACCURACY OF THE UTILITIES SHOWN ON THIS DRAWING. PARTIES UTILIZING THIS INFORMATION SHALL FIELD VERIFY. PRIOR TO CONSTRUCTION ALL LOCATIONS AND DEPTHS OR EXISTING UTILITIES (IN CONFLICT WITH PROPOSED IMPROVEMENTS) SHALL BE VERIFIED IN THE FIELD. CALL MISS DIG 3 WORKING DAYS PRIOR TO CONSTRUCTION.

AutoCAD SHX Text

STORAGE BUILDING

AutoCAD SHX Text

ABANDONED PRIMARY TANKS

AutoCAD SHX Text

CONTROL BUILDING

AutoCAD SHX Text

SCREENING ROOM

AutoCAD SHX Text

HYD.

AutoCAD SHX Text

EX. 6" WTR.MAIN

AutoCAD SHX Text

EX. 12" WTR.MAIN

AutoCAD SHX Text

12" WTR.MAIN

AutoCAD SHX Text

EX. 12" WTR.MAIN

AutoCAD SHX Text

EX. 27" SAN.

AutoCAD SHX Text

EX. 30" SAN.

AutoCAD SHX Text

EX. N.G. LINE

AutoCAD SHX Text

GENERATOR STRUCTURAL FOUNDATION PAD

AutoCAD SHX Text

MAINTENANCE STRIP CONCRETE, 6" NON-REINFORCED

AutoCAD SHX Text

EX. CONC. S.W.

AutoCAD SHX Text

EXISTING LEGEND

AutoCAD SHX Text EXISTING FENCE EXISTING SANITARY SEWER LINE EXISTING FIRE MAIN WATER LINE EXISTING STORM SEWER LINE EXISTING STEAM CONDENSATE LINE EXISTING ELECTRICAL SITE POWER EXISTING GAS MAIN LINE EXISTING WATER MAIN LINE EXISTING COLD DOMESTIC WATER EXISTING COMMUNICATIONS LINE EXISTING PIV EXISTING WATER HYDRANT EXISTING LIGHT POLE EXISTING STORM CATCH BASINS EXISTING SANITARY MANHOLE EXISTING GATE VALVE

AutoCAD SHX Text

PIV

AutoCAD SHX Text

SA

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

GARAGE AREA/ STORAGE

AutoCAD SHX Text

NEW HMA PAVEMENT PATCHING

AutoCAD SHX Text

GREEN SPACE RESTORATION AREA

AutoCAD SHX Text NOTE: A. CONTRACTOR MAY DIRECTIONAL BORE CONDUITS TO GREEN CONTRACTOR MAY DIRECTIONAL BORE CONDUITS TO GREEN SPACE AND OMIT HMA PAVING REQUIREMENTS. EXISTING DRIVEWAY IS BLOCK CRACKING WHICH MAY CAUSE EXTENDED REPAIRS IF OPENED FOR TRENCHING. USE OF HAND PATCH SHALL BE USED TO REPAIR SMALL DAMAGED AREAS AS REQUIRED.

AutoCAD SHX Text

1.5% MAX

AutoCAD SHX Text

Sheets and Views
Cover

File details come from the government source that posted it. Updated .