GCC-C B2260-047 Project Drawings 2023-07-27.pdf
PDF 17 MB Posted
- Attached to
- Construct Monumental Sign - Daniel Technology Center at New River Community College PC#260-B2260-047
- Solicitation number
- 52912
- Issued by
- Culpeper County, Virginia
About this file
This document appears to be a set of project drawings for a contract opportunity issued by the Government Contracting Center (GCC) under Contract # B2260-047. The project involves the construction or renovation of government facilities and is open to bidders. The drawings provide details on the required work and specifications. No additional information is provided on the full scope of services, response dates, site visits, or contract term.
The document does not contain details on pricing, set asides, incumbents, funding sources, or other salient contract information. Only the project drawings themselves are included, without any supplemental documentation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GERMANNA COMMUNITY COLLEGE
DANIEL TECHNOLOGY CENTER -
MONUMENTAL SIGN
RRMM ARCHITECTS, PC
ARCHITECTURE / PLANNING / INTERIORS
VICINITY MAP CONSULTANTS OWNER LOCATION MAP
NA
CIVIL ENGINEERING
Lynch Mykins
STRUCTURAL ENGINEERING
1519 Summit Avenue, Suite 101 Richmond, VA 23230 804-346-3935
Thompson Consulting Engineers
MEP ENGINEERING
4323 Cox Road Glen Allen, Virginia 23060 804-309-3155
GERMANNA COMMUNITY COLLEGE
18121 Technology Drive Culpeper Virginia, 22701
P: 540-891-3000
SITE
SITE
1317 Executive Boulevard, Suite 200 Chesapeake, VA 23320
(757) 622-2828
28 Church Avenue SW Roanoke, VA 24011
(540) 344-1212
1 Research Court, Suite 450 Rockville, MD 20850
(240) 403-4101
2900 South Quincy Street, Suite 710 Arlington, VA 22206
(703) 998-0101
115 South 15th Street, Suite 202 Richmond, VA 23219
(804) 277-8987
VCCS PROJECT NUMBER:
B2260-047
DEB PN: 260-B2260-047 RRMM PN: 19284-50
BUILDING CODE DESIGN SUPPORTING DATA
PROJECT BASIC DESCRIPTION
THE PROJECT INCLUDES CONSTRUCTION OF A NEW MONUMENTAL SIGN AND POWER
SUPPLY/LIGHTING.
A. APPLICABLE CODES
1. BUILDING CODES:
CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL (CPSM) 2022, REV 1
ISSUED 2/14/23
VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2018
VIRGINIA CONSTRUCTION CODE (VCC) - VUSBC PART I
VIRGINIA ENERGY CONSERVATION CODE (VECC) 2018
VECC COMPLIANCE PATH:
IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE
BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405 AND
C408, AS APPLICABLE.
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE - ACI 318, 2014
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES - ASCE 7, 2016
2. ACCESSIBILITY CODE:
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ASAD) DATED SEPTEMBER 15,
2010 ICC/ANSI 117.1 - 2009
2009 INTERNATIONAL ENERGY CONSERVATION CODE - NEW CONSTRUCTION (TABLE
301.1)_
CULPEPER COUNTY, VIRGINIA. CLIMATE ZONE 4A
STRUCTURAL LOADING INFORMATION
WIND LOADS
ULTIMATE DESIGN WINDOW SPEED (VULT) 112 MPH
EXPOSURE CATEGORY B
COMPONENT AND CLADDING PRESSURES
SOLID SIGN 28.6 PSF
SEISMIC LOADS:
SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY B
IMPORTANCE FACTOR (IF) 1.0
SPECTRAL RESPONSE ACCELERATIONS:
SS......................0.19 S1......................0.05
SMS....................0.304 SM1....................0.12
SDS....................0.203 SD1....................0.08
ASBESTOS DISCLOSURE STATEMENT
FOR NEW CONSTRUCTION:
1. NO ASBESTOS CONTAINING MATERIALS SHALL BE USED ON THIS
PROJECT.
Lic. No. 5269
DAN H. HICKOK JR.
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/1 /2
:0
:1
A
M A u to d e s k D o c s /1
-5
G C
C C u lp e p e r
E x te ri o r
S ig n /1
-5 v
G
C C
C u lp e p e r E x te ri o r S ig n
A R
C H
.r v t
G-001
/2
/2
-5
A R
V
A R
V
T
IT
L E
S H
E E
T
G E
R M
A N
N A
C O
M M
U N
IT
Y
C O
L L E
G E
D A
N
IE
L T
E C
H N
O L
O G
Y C
E N
T E
R
M O
N U
M E
N T
A L
S
IG
N
D E
B P
R O
J E
C T
C O
D E
-B
-0
T e c h n o lo g y D r C u lp e p e r, V A
SHEET INDEX
Sheet Number Sheet Title DISCIPLINE
PROJECT TITLE SHEET
G-001 TITLE SHEET PROJECT TITLE
SHEET
ARCHITECTURAL
A-001 ARCHITECTURAL GENERAL INFORMATION ARCHITECTURAL
A-101 SITE PLAN ARCHITECTURAL
A-102 ELEVATIONS AND SECTIONS ARCHITECTURAL
ELECTRICAL
E-001 ELECTRICAL LEGEND, ABBREVIATIONS, RISER
AND SCHEDULE
ELECTRICAL
E-002 SPECIFICATIONS ELECTRICAL
E-003 SPECIFICATIONS ELECTRICAL
E-101 ELECTRICAL LEGEND, ABBREVIATIONS AND
ELECTRICAL SITE PLAN
ELECTRICAL
GENERAL NOTES
1. ALL WORK SHALL INCLUDE ALL LABOR, ASSEMBLIES AND FINISH WORK, INCLUDING ALL PARTS AND
MATERIALS NECESSARY TO MAKE A COMPLE AND WORKMANLIKE JOB.
2. ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS SHALL BE CLARIFIED WITH TEH OWNER'S REPRESENTATIVE AND ARCHTIECT/ENGINEER BEFORE PROCEEDING WITH THE WORK.
3 THE WORK SHALL BE PERFORMED INSTRICT ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL CODES AN ORDINANCES. REFER ANY QUESTIONS TO THE CLIENT REPRESENTATIVES AND
PROFESSIONAL REPRESENTATIVES FOR RESOLUTION PRIOR TO PROCEEDING
4. THE AGENCY SHALL SECURE AND PAY FOR ALL PERMITS, FEES, LICENSES ADN INSPECTIONS
NECESSARY FOR A PROPER COMPLETION OF ALL WORK REQUIRED BY TEH DOCUMENTS.
5. ALL CONTRACTORS SHALL VISIT THE PORJECT SITE TO FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. BY SUBMITTEING A BID, THE CONTRACTOR AND HIS SUBCONTRACTORS ARE CONFIRMING THAT THEY HAVE VISTIED THE SITE AND HAVE INCLUDE IN THEIR BID ANY ADDITIONAL ITEMS OF CONSTRUCTION THAT MAY BE REQUIRED DUE TO EXISTIN SITE CONDITIONS.
6. GC TO VERIFY EXISTING CONDITIONS AND REPORT DIFFERENCES BETWEEN THESE DOUCMENTS AND
ACTUAL FIELD CONDITIONS TO THE ARCHITECT FOR RESOLUTION.
7. CONTRACTOR SHALL FIELD MEASURE ALL DISTANCES AND CLEARANCES PRIOR TO COMMENCEMENT OF NEW WORK OR ORDERING MATERIALS. ANY DEVIATIONS TO THE CONTRACT DOCUMENTS SHALL BE REPORTED TO OWNER REPRESENTATIVE AND PROFESSIONAL REPRESENTATIVE PRIOR TO PROCEEDING WITH THAT PORTION OF WORK. DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS OR SIZES. VERIFY ALL
DIMENSIONS IN THE FIELD.
8. PRIOR TO PROCEEDING WITH ANY WORK THAT MAY RESULT IN ADDITIONAL COST OR ADDITIONAL TIME TO THE PROJECT THE CONTRACTOR SHALL DETERMINE THE ADDITIONAL COST OR TIME (OR IF EXACT COST OR TIME CANNOT BE DETERMINED, THE CONTRACTOR SHALL MAKE HIS MOST REASONABLE ESTIMATE AND AN ESTIMATE OF THE WORST CASE) AND SUBMIT THE ADDITIONS TO THE CLIENT REPRESENTATIVE FOR APPROVAL, SHOULD THE CONTRACTOR FAIL TO ADVISE THE CLIENT REPRESENTATIVE PRIOR TO
PROCEEDING WITH THE WORK, ADDITIONAL COST OR TIME WILL NOT BE APPROVED.
9. CONTACT THE FACILITY MANAGEMENT PRIOR TO STARTING WORK TO OBTAIN ALL RULES AND REGULATIONS FOR USE OF, AND CONSTRUCTION IN, THE PROPERTY, COORDINATE WITH THE MANAGEMENT THE HOURS OF PROPERTY OPERATION, NOISE RESTRICTIONS, NECESSARY BLOCKAGES AND SAFETY BARRIERS, DUST AND MOISTURE CONTROL, USE OF FACILITY DOCK AND ELEVATORS, USES OF TOILET ROOMS AND UTILITIES, PLACEMENT OF TRASH CONTAINER AND HOURS OF TRANSPORT AND REMOVAL, UTILITY USE AND HOURS UTILITIES MAY BE INTERRUPTED IF NECESSARY AND PRIOR NOTIFICATION REQUIREMENTS, PARKING FOR CONSTRUCTION WORKERS, AND ANY OTHER ITEMS THAT WILL AFFECT THE FUNCTION OF THE PROPERTY OR ITS OCCUPANTS. THE CONTRACTOR SHALL CONFINE HIS APPARATUS, DELIVERY AND STORAGE MATERIALS, AND THE OPERATIONS OF HIS WORKMEN TO LIMITS DEFINED BY
FACILITIES MANAGEMENT.
10. THE CONTRACTOR SHALL SCHEDULE ALL WORK TO AVOID INTERRUPTIONS TO NORMAL OPERATIONS OF OTHER PROPERTY OCCUPANTS. ALL DISRUPTIVE WORK SHALL BE SCHEDULED AND COORDINATED WITH
THE FACILITIES MANAGEMENT.
11. IDENTIFY DELIVERY ITEMS FOR ALL ITEMS AND PLACE THE ORDERS FOR THE LONG LEAD TIME ITEMS SO
AS NOT TO DELAY THE PROJECT.
12. THE CONTRACTOR SHALL USE AND PROTECT THE EXISTING FINISHES SCHEDULED TO REMAIN IN A MANNER WHICH WILL NOT SOIL, DEFACE OR DAMAGE THE EXISTING FACILITIES, FINISHES OR FIXTURES IN ANY FASHION. PROVIDE PROTECTIVE MATERIALS AS NECESSARY. DAMAGE BY THE CONTRACTOR SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR THE TO THE COMPLETE SATISFACTION OF AND AT NO COST
TO THE OWNERS REPRESENTATIVE, OWNER, OR PROFESSIONALS. AFTER ANY WORK HAS BEEN
COMPLETED WITHIN ANY OCCUPIED SPACES, THE CONTRACTOR SHALL CLEAN THE SPACE OF ALL
CONSTRUCTION DUST, TOOLS , STAINS, AND DEBRIS.
13. PROVIDE A SECURE OWNER SPACE DURING NON CONSTRUCTION HOURS.
14. REMOVE ALL CONSTRUCTION DEBRIS AS REQUIRED MAINTAINING A CLEAN ENVIRONMENT.
15. ALL WOOD BLOCKING TO BE FIRE RETARDANT TREATED/ PRESSURE TREATED. ALL FIRE RETARDANT
TREATED WOOD SHALL HAVE A FLAME SPREAD LESS THAN 25 WHEN TESTED PER E 84.
INCLUDING VDOT.
16. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY CODE
17. PROVIDE A FINAL PROFESSIONAL CLEANING OF THE ENTIRE SPACE AFTER
CONSTRUCTION AND PUNCH LIST ITEMS ARE COMPLETED PRIOR TO OWNER POSSESSION
AND OCCUPANCY.
18. PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL ASSEMBLE ORIGINAL COPIES OF ALL
NEW EQUIPMENT AND MATERIALS WARRANTIES AND OPERATIONAL INFORMATION AND
DELIVER TO THE FACILITY MANAGER IN A NEATLY INDEXED AND LABELED 3 RING BINDER.
19. CONTRACTOR SHALL FURNISH ALL ITEMS SHOWN ON THE DOCUMENTS UNLESS
SPECIFICALLY NOTED OTHERWISE.
20. ALL CUTTING AND PATCHING SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE
MANNER. ANY CONCRETE OR ASPHALT DISTURBED WILL BE BROUGHT BACK TO ORIGINAL
CONDITION.
21. COORDINATION WITH ELECTRICAL TRADES WILL FIELD VERIFY ELECTRICAL SERVICE
AVAILABILITY AND DEAL WITH ELECTRICAL SERVICE PROVIDERS AS NECESSARY TO
COMPLETE WORK. CONTRACTOR WILL PROVIDE ANY EQUIPMENT AND ITEMS NOT PROVIDED
BY THE ELECTRICAL SERVICE PROVIDER TO COMPLETE PROJECT
22. CONTRACTOR WILL NOTIFY OWNER REPRESENTATIVE AND PROFESSIONAL
REPRESENTATIVE OF ANY UNFORESEEN CONDITIONS OF SOILS CONDITIONS OR SUBSURFACE
DISCOVERIES IMMEDIATELY BEFORE CONTINUANCE OF THE WORK.
23. THE AGENCY IS RESPONSIBLE FOR ACQUISITION OF ALL APPLICABLE PERMITS INCLUDING
VDOT.
24. DIG NOTICE - CONTACT VIRGINIA 811 AT 811, 1-800-552-7001, OR HTTPS://WWW.VA811.COM
NO LESS THAN 72 HOURS PRIOR TO EXCAVATION AND DO NOT DISTURB THE SOIL UNTIL DIG
TICKET HAS BEEN PROCESSED.”
TOILET ACCESSORIES
DOOR TAG -
BUILDING DIV/DOOR NUMBER
LOCATION SUFFIX (IF REQ'D)
XX WINDOW TYPE
EXTERIOR / INTERIOR / INTERIOR CASEWORK
ELEVATION IDENTIFICATION NUMBER
SF
XX
WINDOW FRAME TYPES
(REF A600 SERIES DRAWINGS)
STOREFRONT
XX
XX
SIGNAGE TYPE
SIGNAGE NUMBER ARCH NUMBER
ROOM NAME
BLDG DIV / CONST NO.
MSR8 PARTITION TYPE (SEE
PARTITION LEGEND)
LOUVER TYPELX
AXXX
X
SHEET NUMBER WHERE ELEVATION
IS LOCATED
CW
XX
HM
XX
X NEW WORK KEY NOTE
HOLLOW METAL FRAME TYPES
(REF A600 SERIES DRAWINGS)
HOLLOW METAL FRAME
CURTAIN WALL TYPES
(REF A600 SERIES DRAWINGS)
CURTAIN WALL
CONTROL JOINT
ELEVATION REFERENCE
ARCHITECTURAL GRAPHIC SYMBOLS
X
ROOM
A101
X
A
A
MATCH LINE
SEE 1 A101
SECTION NUMBER
BUILDING SECTION REFERENCE
DRAWING NUMBER WHERE SECTION IS DRAWN
SECTION NUMBER
SECTION REFERENCE
DRAWING NUMBER WHERE SECTION IS DRAWN
SECTION NUMBER
SECTION REFERENCE
DRAWING NUMBER WHERE SECTION IS DRAWN
SCALE:
TITLE
1/8" = 1'-0"
SCALE:
1 View Name 1/8" = 1'-0"A-1.2A-1.1
DRAWING TITLE
MAIN DRAWING TITLE
DRAWING SCALE
DRAWING TITLE
DRAWING TITLE WITH REFERENCE SYMBOL
DRAWING SCALE1
A-1.1 A-1.3 DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
DRAWING NUMBER DESIGNATION
DRAWING REFERENCE NUMBER
DRAWING REFERENCE NUMBER
DRAWING REFERENCE NUMBER
A-1.2 A-2.1
A-1.2 A-2.1
A-1.2 A-2.1
A-1.2 A-2.1
DEMOLITION KEY NOTE
3D VIEW REFERENCE
1/ A101
DRAWING SHEET
NUMBER
DRAWING
NUMBER
DESIGNATION
CONTINUOUS WOOD BLOCKING
CONCRETE MASONRY UNIT
CAST-IN-PLACE CONCRETE
STEEL
EARTH / COMPACT FILL
BATT INSULATION
POROUS FILL / GRAVEL
RIGID INSULATION
GYPSUM BOARD
RESILIENT FLOORING / PLASTIC LAMINATE
ALUMINUM
FINISHED WOOD
WOOD BLOCKING
BRICK
GLASS
ACOUSTICAL TILE
PLYWOOD
CERAMIC TILE - LARGE SCALE
SAND / MORTAR / PLASTER
GRAVEL
ARCHITECTURAL MATERIAL LEGEND
Lic. No. 5269
DAN H. HICKOK JR.
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/1 /2
:0
:1
A
M A u to d e s k D o c s /1
-5
G C
C C u lp e p e r
E x te ri o r
S ig n /1
-5 v
G
C C
C u lp e p e r E x te ri o r S ig n
A R
C H
.r v t
A-001
/2
/2
-5
D e s ig n e d B y
D ra w n B y
C h e c k e d B y A
R C
H
IT
E C
T U
R A
L G
E N
E R
A L I
N F
O R
M A
T
IO
N
G E
R M
A N
N A
C O
M M
U N
IT
Y
C O
L L E
G E
D A
N
IE
L T
E C
H N
O L
O G
Y C
E N
T E
R
M O
N U
M E
N T
A L
S
IG
N
D E
B P
R O
J E
C T
C O
D E
-B
-0
T e c h n o lo g y D r C u lp e p e r, V A
# NUMBER
&, + AND
+/- PLUS OR MINUS
@ AT
° DEGREES
Ø DIAMETER
Ω ARC LENGTH
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABV ABOVE
ACM ASBESTOS CONTAINING
MATERIAL
ACP ACOUSTIC CEILING PANEL
ACT ACOUSTIC CEILING TILE
ADDN ADDITION
ADH ADHESIVE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP, A AMPERE
ANCH ANCHOR, ANCHORAGE
ANOD ANODIZED
AP ACCESS POINT
APC ARCHITECTURAL PRECAST
CONCRETE
APPROX APPROXIMATE
AR ABUSE RESISTANT
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ATTEN ATTENUATION
AUTO AUTOMATIC
AVG AVERAGE
AWP ACOUSTIC WALL PANEL
BC BOTTOM OF CURB
BD BOARD
BEJ BUILDING EXPANSION JOINT
BETW BETWEEN
BIT BITUMINOUS
BL BLEACHER FINISH
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOT, B BOTTOM
BRG BEARING
BRK BRICK
BS BOTH SIDES
BSMT BASEMENT
BTWN, B/W BETWEEN
BUR BUILT-UP ROOFING
BVL BEVELED
C CARPET
CAB CABINET
CAP CAPACITY
CB CHALKBOARD
ABBREVIATIONS
CC CUBICAL CURTAIN
CCTV CLOSED CIRCUIT TELEVISION
CEM CEMENT
CEM TOP CEMENT TOPPING
CER CERAMIC
CF CUBIC FOOT
CFLSHG COUNTER FLASHING
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CHAM CHAMFER
CI CAST IRON
CIP CAST IN PLACE
CIR CIRCLE
CJ CONTROL JOINT
CK CAULK, CAULKING
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CENTIMETER, CENTIMETERS
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
COMP COMPOSITE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT, CONTRACTOR
CORR CORRUGATED
CPT CARPET
CRS COURSE. COURSES
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CU FT CUBIC FEET
CU YD CUBIC YARD
CUH CABINET UNIT HEATER
CW COLD WATER
CWFP CEMENTITIOUS WOOD FIBER
PANELS
D DEEP, DEPTH, DRAIN
DBL DOUBLE
DEMO DEMOLITION
DET / DTL DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPOSAL
DIV DIVISION
DL DEAD LOAD
DMT DEMOUNTABLE
DN DOWN
DPG DAMPPROOFING
DPR DISPENSER
DR DOOR, DISPLAY RAIL
DS DOWNSPOUT
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EF EXHAUST FAN
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION FINISH
SYSTEM
EJ EXPANSION JOINT
ELAS ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATION, ELEVATOR
EM ENTRANCE MAT
EMER EMERGENCY
ENCL ENCLOSE, ENCLOSURE
EP ELECTRICAL PANELBOARD
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPS EXPANDED POLYSTYRENE
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
EWC ELECTRIC WATER COOLER
EXCA EXCAVATE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED / EXPANSION
EXP C EXPANSION CONSTRUCTION
EXT EXTERIOR
FAB FABRICATE
FAS FASTEN, FASTENER
FB FACE BRICK
FCVD FLASH COVED
FD FLOOR DRAIN, FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FEJ FLOOR EXPANSION JOINT
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FG FIBER REINFORCED GYPSUM
BOARD
FGL FIBERGLASS
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH, FINISHED
FIX FIXTURE
FLEX FLEXIBLE
FLR FLOOR
FLSHG FLASHING
FLUOR FLUORESCENT
FLUR FLUORESCENT
FND FEMININE NAPKIN DISPENSER
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUDS
FP FIREPROOF
FPL FIREPLACE
FR FIRE RATED
FRG (GLASS) FIBER REINFORCED
GYPSUM
FRM FRAME, FRAMED
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRT FIRE RETARDANT TREATED
FT FOOT, FEET
FTG FOOTING
FUM FUME HOOD
FUR FURRED, FURRING
FURN FURNITURE
FURR FURRING
G GAS
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT,
CONTRACTOR
GCMU GLAZED FIBER REINFORCED
CONCRETE
GEN GENERAL
GFRC GLASS FIBER REINFORCED
CONCRETE
GL GLASS, GLAZING
GPM GALLONS PER MINUTE
GR GRADE / GROUT
GSU GLAZED STRUCTURAL UNIT
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H HIGH
H/C HANDICAPPED
HB HOSE BIB
HC HOLLOW CORE
HD HAND
HDBD HARDBOARD
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HTG HEATING
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE, INCLUDED, INCLUDING
INFO INFORMATION
INST INSTALLATION
INSUL INSULATE, INSULATED,
INSULATION
INT INTERIOR
INTRLK INTERLOCK
INV INVERT
JAN JANITOR
JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
KIT KITCHEN
KO KNOCKOUT
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
L LENGTH, LONG, LOW
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LB POUND
LF LINEAR FEET
LG LAMINATED GLASS
LH LEFT HAND
LIN LINEAR
LK LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LTG LIGHTING
LTL LINTEL
LVR LOUVER
LW LIGHTWEIGHT
M METER
M/S MOP SINK
MACH MACHINE
MAINT MAINTENANCE
MANUF MANUFACTURE, MANUFACTURER
MAR MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKERBOARD
MBR MODIFIED BITUMEN ROOF
MECH MECHANIC, MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
MM MILLIMETER
MO MASONRY OPENING
MOD MODIFIED
MOV MOVABLE
MR MAP RAIL
MT MOUNT
MTD MOUNTED, MOUNTING
MTL METAL
MULL MULLION
MWP MEMBRANE WATERPROOFING
N NORTH
N/C NO CHARGE
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED /
CONTRACTOR INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
P PLATE
PAR PARALLEL
PART PARTIAL
PC PRE-CAST, PIECE
PED PEDESTAL
PERF PERFORATE (D)
PERM PERIMETER
PIP POURED IN PLACE
PL PROPERTY LINE / PLASTIC
LAMINATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PLYWD PLYWOOD
PNL PANEL
POLY POLYURETHANE
PORT PORCELAIN TILE
PORTB PORCELAIN TILE BASE
PPT PRESERVATIVE PRESSURE
TREATED
PR PAIR
PREFAB PREFABRICATE, PREFABRICATED
PREFIN PRE-FINISHED
PRJ SC PROJECTION SCREEN
PRT PORCELAIN TILE
PS PENCIL SHARPENER
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHLORIDE / PVC
EDGE BAND
PVMT PAVEMENT
QT QUARRY TILE
QTY QUANTITY
R RISER, RIDGE
R/W RIGHT OF WAY
RA RETURN AIR
RAD RADIUS
RAS RESILIENT ATHLETIC SURFACING
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RECP RECEPTACLE
REF REFERENCE
REFRIG REFRIGERATOR
REINF REINFORCE, REINFORCED,
REINFORCING
REM REMOVE
REQD REQUIRED
REQMT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION, REVISIONS, REVISED
RFG ROOFING
RFL REFLECT, REFLECTED,
REFLECTIVE
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RSHT RESILIENT SHEET
RT RUBBER TILE / RUBBER TREAD
RTU ROOF TOP UNIT
S SOUTH
S/S STAINLESS STEEL, SERVICE SINK
SAB SOUND ATTENUATION BLANKET
SAN SANITARY SEWER
SAPC SUSPENDED ACOUSTIC PANEL
CEILING
SC SOLID CORE, SEALED CONCRETE
SCHED SCHEDULE
SCW SOLID CORE WOOD
SD SOAP DISPENSER, STORM DRAIN
SEC SECTION
SF SQUARE FEET
SFGL SAFETY GLASS
SHLVG SHELVING
SHM SECURITY HOLLOW METAL
SHT SHEET
SHTH SHEATHING
SIM SIMILAR
SLR SEALER
SN STAGE NOSE
SND SANITARY NAPKIN DISPOSER
SOF SPRAY-ON FIREPROOFING
SPEC SPECIFICATION, SPECIFICATIONS
SPK SPEAKER
SQ SQUARE
SS SOLID SURFACE
ST STAIN, STONE
STC SOUND TRANSMISSION CLASS
STD STANDARD
STFT STOREFRONT
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUB SUBSTITUTE
SUSP SUSPENDED
SYM SYMMETRICAL, SYMMETRY
SYN SYNTHETIC
SYS SYSTEM
T TREAD
T&B TOP & BOTTOM
TB TACK BOARD
TEL TELEPHONE
TEMP TEMPORARY, TEMPERED
TERR TERRAZZO
TG TONGUE & GROVE
THK THICK, THICKNESS
THRES THRESHOLD
THRU THROUGH
TO TOP OF
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TPT TEXTURED PAINT
TRTD TREATED
TSC TEACHERS STORAGE CABINET
TTD TOILET TISSUE DISPENSER
TV TELEVISION
TW TEACHERS WARDROBE
TYP TYPICAL
UC UNDERCUT
UG UNDER GROUND
UH UNIT HEATER
UNF UNFINISHED
UON UNLESS OTHERWISE NOTED
V VOLT, VALLEY
VAC VACUUM
VAR VARNISH
VB VENTED BASE
VCT VINYL COMPOSITION TILE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VR VAPOR RETARDER
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST, WIDE, WIDTH
W/ WITH
W/O WITHOUT
WAIN WAINSCOT
WB WOOD BASE
WC WATER CLOSET
WD WOOD / WOOD FLOORING
WDB WOOD BASE
WDW WINDOW
WGL WIRE GLASS
WH WATER HEATER
WI WROUGHT IRON
WMS WIRE MANAGEMENT SLOT
WP WATERPROOFING
WPT WORKING POINT
WR WASTE RECEPTACLE
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
/2
± 278' - 8 1/2"
NEW MONUMENTAL SIGN LOCATION.
FIELD VERIFY EXACT LOCATION AT
TOP OF KNOLL WITH OWNER
CLEARING BY OWNER PRIOR
TO CONSTRUCTION -
APPROXIMATELY 330 FEET
ALL EXISTING SETBACKS TO BE
MAINTAINED
INSTALL SILT FENCING AROUND
LIMITS OF DISTURBANCE FOR THE
DURATION OF CONSTRUCTION
Lic. No. 5269
DAN H. HICKOK JR.
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/1 /2
:0
:1
A
M A u to d e s k D o c s /1
-5
G C
C C u lp e p e r
E x te ri o r
S ig n /1
-5 v
G
C C
C u lp e p e r E x te ri o r S ig n
A R
C H
.r v t
A-101
/2
/2
-5
A R
V
S
IT
E P
L A
N
G E
R M
A N
N A
C O
M M
U N
IT
Y
C O
L L E
G E
D A
N
IE
L T
E C
H N
O L
O G
Y C
E N
T E
R
M O
N U
M E
N T
A L
S
IG
N
D E
B P
R O
J E
C T
C O
D E
-B
-0
T e c h n o lo g y D r C u lp e p e r, V A
SCALE: 1" = 50'-0"A-101
4 PARTIAL SCHEMATIC SITE PLAN
SCALE: 1" = 100'-0"A-101
5 SCHEMATIC SITE PLAN - OVERALL
PROPOSED SIGN
LOCATION
DIMENSIONAL LETTER SIGNAGE
SPECIFICATION:
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Illuminated, molded-plastic dimensional characters.
1.3 DEFINITIONS
A. Illuminated: Illuminated by lighting source integrally constructed as part of the sign unit.
1.4 COORDINATION
A. Furnish templates for placement of electrical service embedded in permanent construction by other installers.
1.5 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For dimensional letter signs.
1. Include fabrication and installation details and attachments to other work.
2. Show sign mounting heights, locations of supplementary supports to be provided by others, and accessories.
3. Show message list, typestyles, graphic elements, and layout for each sign at least half size.
4. Show locations of electrical service connections.
5. Include diagrams for power, signal, and control wiring.
C. Samples for Initial Selection: For each type of sign assembly, exposed component, and exposed finish.
1. Include representative Samples of available typestyles and graphic symbols.
D. Samples for Verification: For each type of sign assembly showing all components and with the required finish(es), in manufacturer's standard size unless otherwise indicated and as follows:
1. Dimensional Characters: Full-size Sample of each type of dimensional character.
2. Exposed Accessories: Full-size Sample of each accessory type.
E. Sign Schedule: Use same designations specified or indicated on Drawings or in a sign schedule.
F. Delegated-Design Submittal: For signs indicated in "Performance Requirements" Article.
1. Include structural analysis calculations for signs indicated to comply with design loads; signed and sealed by the qualified professional engineer responsible for their preparation.
1.6 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer and manufacturer.
B. Sample Warranty: For special warranty.
1.7 CLOSEOUT SUBMITTALS
A. Maintenance Data: For signs to include in maintenance manuals.
1.8 QUALITY ASSURANCE
A. Installer Qualifications: Manufacturer of products or an entity that employs installers and supervisors who are trained and approved by manufacturer.
1.9 FIELD CONDITIONS
A. Field Measurements: Verify locations of electrical service embedded in permanent construction by other installers by field measurements before fabrication, and indicate measurements on Shop Drawings
1.10 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of signs that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Deterioration of finishes beyond normal weathering.
b. Separation or delamination of sheet materials and components.
2. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 DIMENSIONAL LETTER SIGNS, GENERAL
A. Regional Materials: Dimensional letter signs shall be manufactured within 500 miles (800 km) of Project site.
2.2 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer to design sign structure and anchorage to withstand design loads as indicated on Drawings.
B. Thermal Movements: For exterior dimensional characters, allow for thermal movements from ambient and surface temperature changes.
1. Temperature Change: [120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.
C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.
2.3 DIMENSIONAL CHARACTERS
A. Molded-Plastic Characters having uniform faces and profiles, and as follows:
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
a. ACE Sign Systems, Inc.
b. ASI Sign Systems, Inc.
c. Diskey Sign Company.
d. Gemini Incorporated.
e. Metallic Arts.
2. Illuminated Characters: Characters with concealed LED lighting including transformers, insulators, and other accessories; with provision for servicing and concealing connections to building electrical system. Space lamps apart from each other and away from character surfaces as needed to illuminate evenly.
a. Power: As indicated on electrical Drawings.
b. Weeps: Provide weep holes to drain water at lowest part of exterior characters.
3. Color: Manufacturer's standard integral color process, in color as indicated by manufacturer's designation.
4. Typeface: Century Gothic.
2.4 DIMENSIONAL CHARACTER MATERIALS
A. Acrylic Sheet: ASTM D 4802, category as standard with manufacturer for each sign, Type UVF (UV filtering).
B. Paints and Coatings for Sheet Materials: Inks, dyes, and paints that are recommended by manufacturer for optimum adherence to surface and are UV and water resistant for colors and exposure indicated.
2.5 ACCESSORIES
A. Fasteners and Anchors: Manufacturer's standard as required for secure anchorage of signage, noncorrosive and compatible with each material joined.
1. Sign Mounting Fasteners:
a. Concealed Studs: Concealed (blind), threaded studs welded or brazed to back of sign material, screwed into back of sign assembly, or screwed into tapped lugs cast integrally into back of cast sign material, unless otherwise indicated.
b. Through Fasteners: Exposed metal fasteners matching sign finish, with type of head indicated, installed in predrilled holes.
B. Adhesives: As recommended by sign manufacturer.
C. Two-Face Tape: Manufacturer's standard high-bond, foam-core tape, 0.045 inch (1.14 mm) thick, with adhesive on both sides.
D. Bituminous Paint: Cold-applied asphalt emulsion complying with ASTM D 1187.
2.6 FABRICATION
A. General: Provide manufacturer's standard sign assemblies according to requirements indicated.
1. Preassemble signs and assemblies in the shop to greatest extent possible. Disassemble signs and assemblies only as necessary for shipping and handling limitations. Clearly mark units for reassembly and installation; apply markings in locations concealed from view after final assembly.
2. Mill joints to a tight, hairline fit. Form assemblies and joints exposed to weather to resist water penetration and retention.
3. Comply with AWS for recommended practices in welding and brazing. Provide welds and brazes behind finished surfaces without distorting or discoloring exposed side. Clean exposed welded and brazed connections of flux, and dress exposed and contact surfaces.
4. Conceal connections if possible; otherwise, locate connections where they are inconspicuous.
5. Internally brace signs for stability and for securing fasteners.
6. Provide rebates, lugs, and brackets necessary to assemble components and to attach to existing work. Drill and tap for required fasteners. Use concealed fasteners where possible; use exposed fasteners that match sign finish.
7. Castings: Fabricate castings free of warp, cracks, blowholes, pits, scale, sand holes, and other defects that impair appearance or strength. Grind, wire brush, sandblast, and buff castings to remove seams, gate marks, casting flash, and other casting marks before finishing.
B. Brackets: Fabricate brackets, fittings, and hardware for bracket-mounted signs to suit sign construction and mounting conditions indicated. Modify manufacturer's standard brackets as required.
1. Stainless-Steel Brackets: Factory finish brackets to match sign background finish unless otherwise indicated.
2.7 GENERAL FINISH REQUIREMENTS
A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.
C. Directional Finishes: Run grain with long dimension of each piece and perpendicular to long dimension of finished trim or border surface unless otherwise indicated.
D. Organic, Anodic, and Chemically Produced Finishes: Apply to formed metal after fabrication but before applying contrasting polished finishes on raised features unless otherwise indicated.
2.8 STAINLESS-STEEL FINISHES
A. Surface Preparation: Remove tool and die marks and stretch lines, or blend into finish.
B. Polished Finishes: Grind and polish surfaces to produce uniform finish, free of cross scratches.
1. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and leave surfaces chemically clean.
2. Directional Satin Finish: No. 4.
3. Dull Satin Finish: No. 6.
4. Reflective, Directional Polish: No. 7.
5. Mirrorlike Reflective, Nondirectional Polish: No. 8.
2.9 CLEAR ORGANIC COATING FOR COPPER-ALLOY FINISHES
A. Clear Organic Coating: Clear, waterborne, air-drying, acrylic lacquer called "Incralac"; specially developed for coating copper-alloy products; consisting of a solution of methyl methacrylate copolymer with benzotriazole to prevent breakdown of the film in UV light; shop applied in two uniform coats per manufacturer's written instructions, with interim drying between coats and without runs or other surface imperfections, to a total dry film thickness of 1 mil (0.025 mm).
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of signage work.
B. Verify that sign-support surfaces are within tolerances to accommodate signs without gaps or irregularities between backs of signs and support surfaces unless otherwise indicated.
C. Verify that electrical service is correctly sized and located to accommodate signs.
D. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. General: Install signs using mounting methods indicated and according to manufacturer's written instructions.
1. Install signs level, plumb, true to line, and at locations and heights indicated, with sign surfaces free of distortion and other defects in appearance.
2. Before installation, verify that sign surfaces are clean and free of materials or debris that would impair installation.
3. Corrosion Protection: Coat concealed surfaces of exterior aluminum in contact with grout, concrete, masonry, wood, or dissimilar metals, with a heavy coat of bituminous paint.
B. Mounting Methods:
1. Concealed Studs: Using a template, drill holes in substrate aligning with studs on back of sign.
Remove loose debris from hole and substrate surface.
a. Masonry Substrates: Fill holes with adhesive. Leave recess space in hole for displaced adhesive. Place sign in position and push until flush to surface, embedding studs in holes.
Temporarily support sign in position until adhesive fully sets.
b. Thin or Hollow Surfaces: Place sign in position and flush to surface, install washers and nuts on studs projecting through opposite side of surface, and tighten.
2. Projecting Studs: Using a template, drill holes in substrate aligning with studs on back of sign.
Remove loose debris from hole and substrate surface.
a. Masonry Substrates: Fill holes with adhesive. Leave recess space in hole for displaced adhesive. Place spacers on studs, place sign in position, and push until spacers are pinched between sign and substrate, embedding the stud ends in holes. Temporarily support sign in position until adhesive fully sets.
b. Thin or Hollow Surfaces: Place spacers on studs, place sign in position with spacers pinched between sign and substrate, and install washers and nuts on stud ends projecting through opposite side of surface, and tighten.
3. Through Fasteners: Drill holes in substrate using predrilled holes in sign as template.
Countersink holes in sign if required. Place sign in position and flush to surface. Install through fasteners and tighten.
4. Back Bar and Brackets: Remove loose debris from substrate surface and install backbar or bracket supports in position so that signage is correctly located and aligned.
5. Adhesive: Clean bond-breaking materials from substrate surface and remove loose debris.
Apply linear beads or spots of adhesive symmetrically to back of sign and of suitable quantity to support weight of sign after cure without slippage. Keep adhesive away from edges to prevent adhesive extrusion as sign is applied and to prevent visibility of cured adhesive at sign edges.
Place sign in position, and push to engage adhesive. Temporarily support sign in position until adhesive fully sets.
6. Two-Face Tape: Clean bond-breaking materials from substrate surface and remove loose debris. Apply tape strips symmetrically to back of sign and of suitable quantity to support weight of sign without slippage. Keep strips away from edges to prevent visibility at sign edges. Place sign in position, and push to engage tape adhesive.
3.3 ADJUSTING AND CLEANING
A. Remove and replace damaged or deformed characters and signs that do not comply with specified requirements. Replace characters with damaged or deteriorated finishes or components that cannot be successfully repaired by finish touchup or similar minor repair procedures.
B. Remove temporary protective coverings and strippable films as signs are installed.
C. On completion of installation, clean exposed surfaces of signs according to manufacturer's written instructions, and touch up minor nicks and abrasions in finish. Maintain signs in a clean condition during construction and protect from damage until acceptance by Owner.
A-102A-102
10' - 0"
9' - 4"
BRICK VENEER ON 4"
BRICK LEDGE (TYP.)
FOOTING BELOW
CONCRETE
FOUNDATION
2"
CLR. (TYP.)
C L R
(T
Y P
#6 @ 12" O.C.
#3 TIES TYP. REF
SECTION FOR SPACING
GRADE
6" REVEL - BLACK
1" REVEL - BLACK
1" REVEL -
BLACK
METAL SKIN OVER METAL
TUBE STRUCTURE - PMS
RED 201 PAINT COLOR
CONCRETE FOUNDATION
FOOTING
BRICK PEDESTAL - TO MATCH
BUILDING BRICK COLOR & SIZE
INTERNAL STEEL TUBE
FRAMING BY SIGN
MANUFACTURER
SIGN BASE PLATES AND
ANCHOR BOLTS IMBEDDED
IN CONCRETE - BY SIGN
MANUFACTURER
GERMANNA
COMMUNITY
COLLEGE
± 10' - 0"
Joseph R. Daniel Technology Center www.germanna.edu
GRADE
6" REVEL - BLACK
12" ACCENT BAND
± 1' - 0"1" REVEL - BLACK
1" REVEL - BLACK
FUTURE 4'x8'
DIGITAL DISPLAY
LOCATION
12" CLEAR ILLUMINATED
LETTERING ON 1" STANDOFFS
6" WHITE LETTERING
CONCRETE FOUNDATION
FOOTING
BRICK ROWLOCK ON BRICK
RUNNING BOND PEDESTAL.
BRICK TO MATCH SCHOOL
BRICK COLOR AND SIZE
A-102A-102
12" ACCENT
BAND (WHITE)
METAL SIGN SKIN OVER
METAL TUBE SUPPORTS -
PMS RED 201 PAINT
COLOR
MAXIMUM SIGN AND
BASE TOTAL HEIGHT
SHALL BE 15'-0" FROM
AVERAGE GRADE
INTERNAL STEEL TUBE
FRAMING BY SIGN
MANUFACTURER
SIGN BASE PLATES AND
ANCHOR BOLTS
IMBEDDED IN
CONCRETE - PLATE AND
BOLT DESIGN BY SIGN
MANUFACTURER
COMMUNICATION AND
POWER CONDUIT -
REFERENCE ELECTRICAL
DRAWINGS
BRICK VENEER - ATTACHED
TO CONCRETE PIER WITH
DOVETAIL ANCHORS AT 16"
O.C. EACH WAY
#5 @ 10" O.C.
#6 DOWELS WITH
STANDARD 90 DEGREE
HOOKS @ 12" O.C.
(7) #5 CONT.
#5 @ 12" O.C.
6' - 0"
C L R
4"
M
IN
IM
U
M
TYP.
4' - 0"
METAL SIGN ( BY SIGN
MANUFACTURER)
ANCHORL BOLTS (BY SIGN
MANUFACTURER)
(3) #3 TIES @ 3" O.C. AT
EACH SET OF VERTICAL # 6
DOWEL BARS @ ANCHOR
BOLTS
GRADE
1' - 4"
3 13/16"2" CLEAR
3"
CLEAR
C L R
C L R
Lic. No. 5269
DAN H. HICKOK JR.
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/1 /2
:0
:1
A
M A u to d e s k D o c s /1
-5
G C
C C u lp e p e r
E x te ri o r
S ig n /1
-5 v
G
C C
C u lp e p e r E x te ri o r S ig n
A R
C H
.r v t
A-102
/2
/2
-5
E L
E V
A T
IO
N
S A
N D
S E
C T
IO
N
S
G E
R M
A N
N A
C O
M M
U N
IT
Y
C O
L L E
G E
D A
N
IE
L T
E C
H N
O L
O G
Y C
E N
T E
R
M O
N U
M E
N T
A L
S
IG
N
D E
B P
R O
J E
C T
C O
D E
-B
-0
T e c h n o lo g y D r C u lp e p e r, V A
SCALE: 1/2" = 1'-0"
PLAN
SCALE: 1/2" = 1'-0"A-102
2 North & South Elevations
SCALE: 1/2" = 1'-0"A-102
3 East & West Elevations
SCALE: 3/4" = 1'-0"A-102A-102
4 Section 1
FOUNDATIONS:
1. FOUNDATION DESIGN IS BASED ON AN ASSUMBED ALLOWABLE SOIL
BEARING PRESSURE CAPACITY OF 2,000 PSF. CONTRACTOR SHALL
CONFIRM 2,000 PSF MINIMUM SOIL BEARING CAPACITY WITH AN
INDEPENDENT GEOTECHNICAL TESTING FIRM PRIOR TO PLACING
CONCRETE. CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT A
WRITTEN REPORT OF TEST RESULTS FOR THEIR RECORDS.
2. ALL COMPACTED FILL, EXCAVATIONS, SUBGRADES, AND BEARING
SURFACES SHALL BE OBSERVED AND TESTED BY A GEOTECHNICAL
ENGINEER LICENESED IN THE COMMONWEALTH OF VIRGINIA (OR A
QUALIFIED GEOTECHNICAL TECHNICICAN WORKING UNDER TEH DIRECT
SUPERISION OF A REGISTERED ENGINEER) TO VERIFY SPECIFIED
GEOTECHNICAL CONFORMANCE REQUIREMENTS. THE GEOTECHNICAL
INSPECTOR SHALL BE HIRED BY THE OWNER.
3. LOOSE OR SOFT SOILS SHALL BE CLEANED FROM FOUNDATION
EXCAVATION BBOTTOMS PRIOR TO PLACING OF CONCRETE. SUBGRADES
NEEDING UNDERCUTTING SHALL BE BACKFILLED TO THE ORIGINAL
SUBGRADE ELEVATION WITH SUITABLE FILL (LEAN CONCRETE OR A
GRADED WASHED STONE SUCHA ST NO. 57 OR NO. 67 AGGREGATE)
UNLESS DIRECTED OTHERWISE BY GEOTECHNICAL ENGINEER.
4. WHENEVER POSSIBLE, FOUNDATION CONCRETE SHOULD BE PLACED ON
THE SAME DAY THAT EXCAVATIONS ARE MADE. IF TEH BEARING SOILS ARE
SOFTENED BY SURFACE WATER INTRUSION OR EXPOSURE, THEN THE
SOFTENED SOILS MUST BE REMOVED FROM TEH FOUNDATION
EXCAVATION BOTTOM IMMEDIATELY PRIOR TO PLACING OF CONCRETE. IF
THE EXCAVATION MUST REMAIN OPEN OVERNIGHT, OR IF RAINFALL IS
IMMINENT WHILE THE BEARING SOILS ARE EXPOSED, THENA A 1 TO 3 INCH
THICK LAYER OF LEAN CONCRTE (250 PSI MINIMUM STRENGTH) SHALL BE
PALCED ON TEH BEARING SOILS BEFORE THE PLACEMENT OF
REINFORCING STEEL.
REINFORCED CONCRETE:
1. UNLESS NOTED OTHERWISE, ALL CONCRETE WORK, DETAILING,
FABRICATION, AND PLACING OF REINFORCING AND CONCRETE SHALL BE
GOVERENED BY THE LATEST REVISIONS OF:
A. ACI 318-14
B. CRSI RECOMMENDED PRACTICE OF PLACING REINFROCING BARS.
C. ACI 306 AND ACCI 305 FOR COLD AND HOT WEATHER CONCRETING
RESPECTIVELY.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT WITH A MIXIMUM UNIT
WEIGHT OF 150 POUNDS PER CUBIC FOOT AND SHALL HAVE A MINIMUM 28
DAY COMPRESSIVE STRENGTH EQUAL TO 3,500 PSI.
3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615 AND SHALL BE
GRADE 60 U.N.O.
4. REINFORCING BAR LAP SPLICES AND HOOK DIMENSIONS SHALL BE AS
REQUIRED BY ACI 318-14
5. PER ACI318-14, CHAPTER 19 “DESIGN AND DURABILITY REQUIREMENTS”
FOR CONCRETE, THE PEDESTAL CONCRETE WILL BE EXPOSED TO
FREEZING AND THAWING CYCLES AND THEREFORE HAVE AN EXPOSURE
CLASS OF F1. CONCRETE WITH A F1 EXPOSURE CLASS SHALL HAVE A
MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3500 PSI, A MAXIMUM
WATER TO CEMENT RATIO OF 0.55 AND A TARGET AIR CONTENT OF 5%.
FIELD CONDITIONS:
COLD-WEATHER PLACEMENT: COMPLY WITH ACI 301 AND ACI 306.1 AND AS
FOLLOWS.
1. PROTECT CONCRETE WORK FROM PHYSICAL DAMAGE OR REDUCED
STRENGTH THAT COULD BE CAUSED BY FROST, FREEZING ACTIONS, OR
LOW TEMPERATURES.
2. WHEN AVERAGE HIGH AND LOW TEMPERATURE IS EXPECTED TO FALL
BELOW 40 DEG F FOR THREE SUCCESSIVE DAYS, MAINTAIN DELIVERED
CONCRETE MIXTURE TEMPERATURE WITHIN THE TEMPERATURE RANGE
REQUIRED BY ACI 301.
3. DO NOT USE FROZEN MATERIALS OR MATERIALS CONTAINING ICE OR
SNOW.
4. DO NOT PLACE CONCRETE IN CONTACT WITH SURFACES LESS THAN 35
DEG F, OTHER THAN REINFORCING STEEL.
5. DO NOT USE CALCIUM CHLORIDE, SALT, OR OTHER MATERIALS
CONTAINING ANTIFREEZE AGENTS OR CHEMICAL ACCELERATORS UNLESS
OTHERWISE SPECIFIED AND APPROVED IN MIXTURE DESIGNS.
NOTE: CONTRACTOR TO SUBMIT NEW BRICK AND
MORTAR SAMPLES TO ARCHITECT PRIOR TO
ORDERING MATERIALS. MATCH EXISTING CAMPUS
BRICK AND MORTAR
NOTE: CONTRACTOR SHALL SUBMIT MAIN BODY
COLOR - PMS RED 201 SAMPLE OF COLOR AND
PANEL FINISH TO ARCHITECT FOR REVIEW PRIOR
TO ORDERING MATERIALS
COLOR 2 - WHITE. EQUAL TO 0/0/0/0
COLOR 3 - BLACK. EQUAL TO 0/0/0/100
SIGN CABINET NOTES:
1. #3003 H-14 ALUMINUM SIGN PANELS. MIN. 14
GAUGE (.064 INCH)
2. ALL SEAMS TO BE CAULKED.
3. ALL FASTENERS WILL BE GALVANIZED OF NON-
CORROSIVE
4. STRUCTURAL FRAM TO BE PAINTED PRIOR TO
EXTERIOR SKINS BEING ATTACHED (FOR RUST
PREVENTION).
5. SIGN FACES ALLOW ACCESS TO INTERNAL
LIGHTING/REPAIRS WITHOUT NEEDING TO TAKE
APART THE SIGN.
6. PROVIDE DRAINAGE HOLES IN BASE OF METAL
SIGN CABINET
E001
LE
G
EN
D
, A
BB
R
EV
IA
TI
O N
S, R
IS
ER
A N
D S
C H
ED
U
LE
RRMM
ARCHITECTS, PC
DA
TE
DR
AW
N
PR
OJ
EC
T
DE
SI
GN
ED
CH
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M
AR
K
RE
VI
SI
ON
SDA
TE
BY
DE
SC
RI
PT
IO
N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
OJ
EC
T
DR
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
9/ 7/
:1
0:
P M
Au to de sk
D oc s:
//1
-5
G C
C C ul pe pe r E xt er io r S ig n/
4-v
G C
C C ul pe pe r E xt er io r S ig n
- A R
C H
.rv t
7/
/2
4-
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
D
AN
IE
L
TE
CH
NO
LO
GY
C
EN
TE
R
- M
ON
UM
EN
TA
L S
IG
N
D
EB
P R
O
JE
C T
C O
D E
0-
B2
0-
Te ch no log y D r Cu lpe pe r, VA
KG
D
M W
H
KC
THOMPSON
Consulting Engineers
4323 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 21-174
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
ELECTRICAL LEGEND ABBREVIATIONS:
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICK MARKS INDICATES
2 #12 CONDUCTORS & 1 #12 GROUND IN 1/2" CONDUIT U.O.N. TICK MARKS, WHEN
SHOWN, INDICATE NUMBER OF CONDUCTORS IF OTHER THAN THREE: (7)
INDICATES GROUNDING CONDUCTOR.
HOMERUNS TO PANEL. PANEL & CIRCUIT DESIGNATIONS AS INDICATED.
DUPLEX RECEPTACLE, 20A, 120V. "WP" INDICATES WEATHERPROOF WHILE IN
USE. "GFI" INDICATES GROUND FAULT INTERRUPTER.
CONSTRUCTION NOTE INDICATOR.
WALL MOUNTED PHOTOCELL, 2000W. INSTALL AT TOP OF SALT TREATED WOOD
POST. COORDINATE INSTALLATION WITH R.E.C. METERBASE.
PAD MOUNTED TRANSFORMER
POWER RISER DIAGRAM
NOT TO SCALE
METER BASE SUPPLIED BY R.E.C.
INSTALLED BY ELECTRICAL
CONTRACTOR
PANEL "L"
APPROX. 3'
APPROX. 65"
R.E.C. PAD MOUNTED
TRANSFORMER
3/4" X 10' COPPER CLAD
GROUND ROD
PROVIDE A SERVICE ENTRANCE RATED PANELBOARD IN NEMA 3R ENCLOSURE.
APPROX.
B.F.G.
BKR
CKT
GFI
GND
KAIC
M.C.B.
MTD
N.E.C
NEMA
NO.
Ø
PSI
PVC
R.E.C
U.O.N.
V
W
WP
Y
APPROXIMATE
BELOW FINISHED GRADE
BREAKER
CIRCUIT
GROUND FAULT INTERRUPTER
GROUND
KILO-AMPERE INTERRUPTING CAPACITY
MAIN CIRCUIT BREAKER
MOUNTED
NATIONAL ELECTRICAL CODE, 2017
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NUMBER
PHASE
POUNDS PER SQUARE INCH
POLY-VINYL CHLORIDE
RAPPAHANNOCK ELECTRICAL COOPERATIVE
UNLESS OTHERWISE NOTED
VOLT
WIRE
WEATHERPROOF
WYE
T L1-3
POWER RISER DIAGRAM NOTES
PROVIDE A 4" PVC CONDUIT WITH PULLWIRE STUBBED-OUT 5'-0" BEYOND R.E.C.
TRANSFORMER PAD FOR USE BY R.E.C. COORDINATE EXACT LOCTION WITH R.E.C.
PROVIDE A 2", SCHEDULE 80 PVC CONDUIT WITH PULLWIRE FOR USE BY R.E.C.
INSTALL AS DIRECTED BY R.E.C.
PROVIDE 3 #1 COPPER CONDUCTORS IN 1-1/4", SCHEDULE 80 PVC CONDUIT
BETWEEN LOAD SIDE OF THE R.E.C. METER AND PANEL "L". COORDINATE WITH
R.E.C.
PROVIDE A #6 COPPER GROUNDING ELECTRODE CONDUCTOR IN 3/4" CONDUIT
AND CONNECT TO A 3/4" X 10' COPPER CLAD GROUND ROD. INSTALL GROUND
ROD IN ACCORDANCE WITH NEC ARTICLE 250.53(G).
PROVIDE AN 8" X 8" SALT TREATED WOOD POST TO SUPPORT THE R.E.C. METER
BASE, PANLE "L" AND RECEPTACLE. EMBED IN A MINIMUM OF 3' OF 3,000 PSI
CONCRETE.
PROVIDE A GFI RECEPTACLE IN AN EXTRA HEAVY-DUTY WEATHERPROOF OUTLET
BOX WITH AN EXTRA HEAVY-DUTY WEATHERPROOF WHILE IN USE COVER PLATE
SURFACE MOUNTED ON WOOD POST.
PROVIDE ARC-FLASH HAZARD WARNING LABEL IN ACCORDANCE WITH NEC 110.16.
PANELBOARD "L" IS A SERVICE
ENTRANCE RATED 120/240V, 1 PHASE,
3W, 125A MCB. WITH A 10 KAIC
RATING. THE ELECTRICAL DEMAND
FOR THE MARQUEE SIGN IS 0.12 KW.
THE ELECTRICAL DEMAND FOR THE
SERVICE RECEPTACLE IS 0.18 KW.
THE TOTAL ELECTRICAL DEMAND FOR
THIS SERVICE IS 0.3 KW.
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text H
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
KENZIE CAMBAR
AutoCAD SHX Text Lic. No.049752
AutoCAD SHX Text 3-1-2023
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MARQUEE SIGN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PANEL "L" 125 AMP 120/240V, 1%%C, 3W, M.C.B, SURFACE MTD.
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
CKT.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
WIRE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TRIP
AutoCAD SHX Text
CKT.BKR.
AutoCAD SHX Text
KAIC
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CKT.
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
WIRE
AutoCAD SHX Text
CKT.BKR.
AutoCAD SHX Text
TRIP
AutoCAD SHX Text
KAIC
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
WP,GFI
AutoCAD SHX Text
AutoCAD SHX Text
WP,GFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
AutoCAD SHX Text T
E002
SP
EC
IF
IC
AT
IO
N S
RRMM
ARCHITECTS, PC
DA
TE
DR
AW
N
PR
OJ
EC
T
DE
SI
GN
ED
CH
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M
AR
K
RE
VI
SI
ON
SDA
TE
BY
DE
SC
RI
PT
IO
N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
OJ
EC
T
DR
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
9/ 7/
:1
0:
P M
Au to de sk
D oc s:
//1
-5
G C
C C ul pe pe r E xt er io r S ig n/
4-v
G C
C C ul pe pe r E xt er io r S ig n
- A R
C H
.rv t
7/
/2
4-
GE
RM
AN
NA
C
OM
MU
NI
TY
C
OL
LE
GE
D
AN
IE
L
TE
CH
NO
LO
GY
C
EN
TE
R
- M
ON
UM
EN
TA
L S
IG
N
D
EB
P R
O
JE
C T
C O
D E
0-
B2
0-
Te ch no log y D r Cu lpe pe r, VA
KG
D
M W
H
KC
THOMPSON
Consulting Engineers
4323 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 21-174
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
260100 ELECTRICAL GENERAL PROVISIONS SCOPE
THE WORK REQUIRED FOR THIS SECTION INCLUDES LABOR, MATERIALS, EQUIPMENT,
APPURTENANCES, SERVICE AND SUPERVISION TO PROVIDE COMPLETE ELECTRICAL SYSTEMS AS
SHOWN ON THE DRAWINGS.
THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID TO DETERMINE THE EXTENT OF THE WORK.
LACK OF KNOWLEDGE OF EXISTING CONDITIONS WILL NOT BE CONSIDERED A BASIS FOR CHANGE
ORDERS.
SPECIFICATIONS, CODES AND STANDARDS
THE LATEST EFFECTIVE PUBLICATIONS OF THE FOLLOWING STANDARDS, CODES, ETC. FORM A
PART OF THESE SPECIFICATIONS.
ASAD 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
IBC 2018 INTERNATIONAL BUILDING CODE
ICC INTERNATIONAL CODE COUNCIL
ICEA INSULATED CABLE ENGINEERS ASSOCIATION
IECC INTERNATIONAL ENERGY CONSERVATION CODE
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
NEC 2017 NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NESC NATIONAL ELECTRICAL SAFETY CODE
NFPA NATIONAL FIRE PREVENTION ASSOCIATION
NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE 2018 EDITION
OSHA THE OCCUPATIONAL SAFETY AND HEALTH ACT
UL UNDERWRITERS LABORATORIES, INC.
VCC VIRGINIA CONSTRUCTION CODE
DRAWINGS
THE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT OF THE WORK. MINOR VARIATIONS IN
LOCATION OF EQUIPMENT SHALL BE MADE UPON WRITTEN APPROVAL OF THE ENGINEER AT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .