This document is an Addendum for a state and local contract opportunity issued by the Virginia Community College System (VCCS) for the Germanna Community College Daniel Technology Center Monumental Sign project, State Project Code: 260-B2260-047. The addendum modifies the original bid documents dated February 22, 2021, with changes to the lettering type, intent of the internal sign structure, and the inclusion of removable panels for a future digital sign installation. The pre-bid meeting was held on January 4, 2024, and bids are due by 2:00 PM on January 18, 2024, with the bid opening scheduled for January 19, 2024. The contract requires a bid bond, and submissions must acknowledge receipt of this addendum.
The scope of work includes the construction of a monumental sign at the Germanna Community College Daniel Technology Center, consisting of concrete foundations, brick pedestals, aluminum sign panels, and provisions for a future digital display. Pricing is to be inclusive of all work shown in the construction documents. No add alternates are included for the digital display. The contractor shall confirm the soil bearing capacity and comply with all reinforced concrete and cold-weather placement requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Virginia Community College System
300 Arboretum Place
Suite 200
Richmond, VA 23236
Division of Engineering & Buildings (DEB) Project Code: 260-B2260-047
Virginia Community College System - Germanna Community College
18121 Technology Drive
Culpeper, VA 22701
Germanna Community College
Daniel Technology Center -
Monumental Sign
Addendum 1 January 16th, 2024
RRMM ARCHITECTS, PC
115 s. 15th Street, Suite 502
T :804-277-8987
RRMM Project Number: 19284-50
ADDENDUM #1
GERMANNA COMMUNITY COLLEGE, CULPEPER CAMPUS
CONSTRUCT MONUMENTAL SIGN AT DANIEL TECHNOLOGY CENTER
State Project Code: 260-B2260-047
DATE: JANUARY 16th, 2024
This Addendum forms a part of the Construction Documents and modifies the original bidding documents dated February 22, 2021.
The information in this Addendum supersedes any contradictory information or omission set forth in the Contract Documents.
This Addendum consists of five (5) text pages, zero (0) specification section, one (1) drawing sheets, zero (0) sketches, zero (0) pages of substitution request responses, one (1) pages of pre-bid question responses and zero – seven (7) total pages.
THE FOLLOWING CHANGES, ADDITIONS, DELETIONS AND CLARIFICATIONS ARE
HEREBY MADE PART OF THE BIDDING REQUIREMENTS AND CONTRACT
DOCUMENTS FOR THE ABOVE REFERENCED PROJECT AND SHALL BE TAKEN
INTO ACCOUNT IN THE PREPARATION OF ALL BIDS AND THE EXECUTION OF
ALL WORK. BIDDERS SHALL ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN
THE APPROPRIATE SPACE ON THE BID FORM.
PERTAINING TO THE PROJECT MANUAL – TECHNICAL SPECIFICATIONS:
1. NO REVISIONS
PERTAINING TO THE DRAWINGS:
1. REVISED SHEET A102 – Details 2 & 3. Clarifications on the lettering type and intent of internal sign structure.
END OF ADDENDUM 1
PRE-BID QUESTIONS
State Project Code: 260-B2260-047
DATE: JANUARY 16Th, 2024
Question 1: Are you looking for a lump sum bid to include the electrical (meter, panel, post, etc.) as well as the concrete footing and brick work?
Response 1: Confirmed. Bid is to be inclusive of all work shown in the construction documents.
Question 2: The details regarding the lettering at the top of the sign are a bit confusing. Can someone clarify the intention of the finished product? 12" clear letters with 1" standoff doesn't make sense yet. Is the intention push-through acrylic letters with clear edges, or halo lit letters with clear back and 1" standoff?
Response 2: The 12” lettering shall be push-through type internally illuminated. Stand offs are not required.
Reference revised drawing sheet A-102 for additional clarification.
Question 3: What is the intention for the space where the future 4'x8' LED display is to go? A removable 4'x8' panel?
Response 3: Yes, the full 5’x10 central aluminum panel shall be removable on both sides of the sign for future access.
Question 4: Will the LED display be an add alternate? There are a limited number of manufacturers that build displays at those exact measurements that would allow future retrofit to be accomplished effectively without it looking like an afterthought.
Response 4: No, the electronic display will not be an add alternate for this project.
State Project Code: 260-B2260-047
Pre-Bid Meeting Minutes
January 4th, 2024
Bid Due: 2:00pm, January 18, 2024 (per VCCS timepiece)
Bids Received: Sibyl H. Roberts, VCCO
Virginia Community College System
300 Arboretum Place, Suite 200
Richmond Virginia 23236
Telephone: 804-819-4918
Email: sroberts@vccs.edu
Shipping/Mailing – Use Suite 390
Hand-delivery: Use Suite 200
Note: If submitting bid via US Mail, Fedex, et. Submit so as to allow adequate time to confirm receipt in Sibyl’s office
Bid Opening Date: 2:00 PM, January 19, 2024
Modification or Withdrawal of Bid:
Prior to deadline for Receipt of Bids.
Bids may be modified or withdrawn by FAX or Telegram. (Recommend email to Sibyl as well)
Modifications may also be written on the outside of the envelope.
Modification must be signed by individuals signing bid or listed on the Bid
Form
Work Paper: Due by Date & Time set for Opening of Bids – Not mandatory
Bind Bond: Bid Bond is required
Commonwealth of Virginia, Standard Bid Bond Form (CO-10.2)
Note: Fill in all blanks. Do not qualify Bid. Be sure to sign Bid Form. Provide Small
Business Percentage (even if the number is 0)
Discussion Topics:
• Trees along route 15 shall be removed for visibility of the sign under a separate contract.
• Lettering type to be clarified on drawings in Addendum 1
• Removable panels for future installation of a digital sign to be incorporated in Addendum 1.
• Internal structure of the sign shall accommodate the future installation of a 4’x8’ digital sign.
• Standard DGS-30-272 Pre-Bid question form is included in the project manual for submission of questions.
• Pre-Bid Questions are to be received by the architect no later than
1/15/2024.
A-102A-102
10' - 0"
9' - 4"
BRICK VENEER ON 4"
BRICK LEDGE (TYP.)
FOOTING BELOW
CONCRETE
FOUNDATION
2"
CLR. (TYP.)
C L R
(T
Y P
#6 @ 12" O.C.
#3 TIES TYP. REF
SECTION FOR SPACING
GRADE
6" REVEL - BLACK
1" REVEL - BLACK
1" REVEL -
BLACK
080" ALUMINUM SKIN
OVER METAL TUBE
STRUCTURE - PMS RED
201 PAINT COLOR
CONCRETE FOUNDATION
FOOTING
BRICK PEDESTAL - TO MATCH
BUILDING BRICK COLOR & SIZE
INTERNAL FRAMING BY SIGN
MANUFACTURER - PROVIDE
ACCOMODATIONS FOR
FUTURE DIGITAL SIGN
INSTALLATION
SIGN BASE PLATES AND
ANCHOR BOLTS IMBEDDED
IN CONCRETE - BY SIGN
MANUFACTURER
GERMANNA
COMMUNITY
COLLEGE
± 10' - 0"
Joseph R. Daniel Technology Center www.germanna.edu
GRADE
6" REVEL - BLACK
12" ACCENT BAND
± 1' - 0"1" REVEL - BLACK
1" REVEL - BLACK
FUTURE APROXIMATELY 4'x8'
DIGITAL DISPLAY LOCATION -
PROVIDE REMOVABLE ALUMINUM
PANELS BOTH SIDES FOR
FUTURE ACCESS
12" TRANSLUCENT WHITE
ACRYLIC ILLUMINATED PUSH-
THROUGH LETTERING
6" WHITE ACRYLIC LETTERING
CONCRETE FOUNDATION
FOOTING
BRICK ROWLOCK ON BRICK
RUNNING BOND PEDESTAL.
BRICK TO MATCH SCHOOL
BRICK COLOR AND SIZE
A-102A-102
12" ACCENT
BAND (WHITE)
080" ALUMINUM SIGN
SKIN OVER METAL TUBE
SUPPORTS - PMS RED
201 PAINT COLOR
MAXIMUM SIGN AND
BASE TOTAL HEIGHT
SHALL BE 15'-0" FROM
AVERAGE GRADE
INTERNAL FRAMING BY SIGN
MANUFACTURER - PROVIDE
ACCOMODATIONS FOR FUTURE
DIGITAL SIGN INSTALLATION
SIGN BASE PLATES AND
ANCHOR BOLTS
IMBEDDED IN
CONCRETE - PLATE AND
BOLT DESIGN BY SIGN
MANUFACTURER
COMMUNICATION AND
POWER CONDUIT -
REFERENCE ELECTRICAL
DRAWINGS
BRICK VENEER - ATTACHED
TO CONCRETE PIER WITH
DOVETAIL ANCHORS AT 16"
O.C. EACH WAY
#5 @ 10" O.C.
#6 DOWELS WITH
STANDARD 90 DEGREE
HOOKS @ 12" O.C.
(7) #5 CONT.
#5 @ 12" O.C.
6' - 0"
C L R
4"
M
IN
IM
U
M
TYP.
4' - 0"
METAL SIGN ( BY SIGN
MANUFACTURER)
ANCHORL BOLTS (BY SIGN
MANUFACTURER)
(3) #3 TIES @ 3" O.C. AT
EACH SET OF VERTICAL # 6
DOWEL BARS @ ANCHOR
BOLTS
GRADE
1' - 4"
3 13/16"2" CLEAR
3"
CLEAR
C L R
C L R
Lic. No. 5269
DAN H. HICKOK JR.
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
/1
/2
:1
:1
A
M A u to d e s k D o c s /1
-5
G C
C C u lp e p e r
E x te ri o r
S ig n /1
-5 v
G
C C
C u lp e p e r E x te ri o r S ig n
A R
C H
.r v t
A-102
/2
/2
-5
E L
E V
A T
IO
N
S A
N D
S E
C T
IO
N
S
G E
R M
A N
N A
C O
M M
U N
IT
Y
C O
L L E
G E
D A
N
IE
L T
E C
H N
O L
O G
Y C
E N
T E
R
M O
N U
M E
N T
A L
S
IG
N
D E
B P
R O
J E
C T
C O
D E
-B
-0
T e c h n o lo g y D r C u lp e p e r, V A
SCALE: 1/2" = 1'-0"
PLAN
SCALE: 1/2" = 1'-0"A-102
2 North & South Elevations
SCALE: 1/2" = 1'-0"A-102
3 East & West Elevations
SCALE: 3/4" = 1'-0"A-102A-102
4 Section 1
FOUNDATIONS:
1. FOUNDATION DESIGN IS BASED ON AN ASSUMBED ALLOWABLE SOIL
BEARING PRESSURE CAPACITY OF 2,000 PSF. CONTRACTOR SHALL
CONFIRM 2,000 PSF MINIMUM SOIL BEARING CAPACITY WITH AN
INDEPENDENT GEOTECHNICAL TESTING FIRM PRIOR TO PLACING
CONCRETE. CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT A
WRITTEN REPORT OF TEST RESULTS FOR THEIR RECORDS.
2. ALL COMPACTED FILL, EXCAVATIONS, SUBGRADES, AND BEARING
SURFACES SHALL BE OBSERVED AND TESTED BY A GEOTECHNICAL
ENGINEER LICENESED IN THE COMMONWEALTH OF VIRGINIA (OR A
QUALIFIED GEOTECHNICAL TECHNICICAN WORKING UNDER TEH DIRECT
SUPERISION OF A REGISTERED ENGINEER) TO VERIFY SPECIFIED
GEOTECHNICAL CONFORMANCE REQUIREMENTS. THE GEOTECHNICAL
INSPECTOR SHALL BE HIRED BY THE OWNER.
3. LOOSE OR SOFT SOILS SHALL BE CLEANED FROM FOUNDATION
EXCAVATION BBOTTOMS PRIOR TO PLACING OF CONCRETE. SUBGRADES
NEEDING UNDERCUTTING SHALL BE BACKFILLED TO THE ORIGINAL
SUBGRADE ELEVATION WITH SUITABLE FILL (LEAN CONCRETE OR A
GRADED WASHED STONE SUCHA ST NO. 57 OR NO. 67 AGGREGATE)
UNLESS DIRECTED OTHERWISE BY GEOTECHNICAL ENGINEER.
4. WHENEVER POSSIBLE, FOUNDATION CONCRETE SHOULD BE PLACED ON
THE SAME DAY THAT EXCAVATIONS ARE MADE. IF TEH BEARING SOILS ARE
SOFTENED BY SURFACE WATER INTRUSION OR EXPOSURE, THEN THE
SOFTENED SOILS MUST BE REMOVED FROM TEH FOUNDATION
EXCAVATION BOTTOM IMMEDIATELY PRIOR TO PLACING OF CONCRETE. IF
THE EXCAVATION MUST REMAIN OPEN OVERNIGHT, OR IF RAINFALL IS
IMMINENT WHILE THE BEARING SOILS ARE EXPOSED, THENA A 1 TO 3 INCH
THICK LAYER OF LEAN CONCRTE (250 PSI MINIMUM STRENGTH) SHALL BE
PALCED ON TEH BEARING SOILS BEFORE THE PLACEMENT OF
REINFORCING STEEL.
REINFORCED CONCRETE:
1. UNLESS NOTED OTHERWISE, ALL CONCRETE WORK, DETAILING,
FABRICATION, AND PLACING OF REINFORCING AND CONCRETE SHALL BE
GOVERENED BY THE LATEST REVISIONS OF:
A. ACI 318-14
B. CRSI RECOMMENDED PRACTICE OF PLACING REINFROCING BARS.
C. ACI 306 AND ACCI 305 FOR COLD AND HOT WEATHER CONCRETING
RESPECTIVELY.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT WITH A MIXIMUM UNIT
WEIGHT OF 150 POUNDS PER CUBIC FOOT AND SHALL HAVE A MINIMUM 28
DAY COMPRESSIVE STRENGTH EQUAL TO 3,500 PSI.
3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615 AND SHALL BE
GRADE 60 U.N.O.
4. REINFORCING BAR LAP SPLICES AND HOOK DIMENSIONS SHALL BE AS
REQUIRED BY ACI 318-14
5. PER ACI318-14, CHAPTER 19 “DESIGN AND DURABILITY REQUIREMENTS”
FOR CONCRETE, THE PEDESTAL CONCRETE WILL BE EXPOSED TO
FREEZING AND THAWING CYCLES AND THEREFORE HAVE AN EXPOSURE
CLASS OF F1. CONCRETE WITH A F1 EXPOSURE CLASS SHALL HAVE A
MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3500 PSI, A MAXIMUM
WATER TO CEMENT RATIO OF 0.55 AND A TARGET AIR CONTENT OF 5%.
FIELD CONDITIONS:
COLD-WEATHER PLACEMENT: COMPLY WITH ACI 301 AND ACI 306.1 AND AS
FOLLOWS.
1. PROTECT CONCRETE WORK FROM PHYSICAL DAMAGE OR REDUCED
STRENGTH THAT COULD BE CAUSED BY FROST, FREEZING ACTIONS, OR
LOW TEMPERATURES.
2. WHEN AVERAGE HIGH AND LOW TEMPERATURE IS EXPECTED TO FALL
BELOW 40 DEG F FOR THREE SUCCESSIVE DAYS, MAINTAIN DELIVERED
CONCRETE MIXTURE TEMPERATURE WITHIN THE TEMPERATURE RANGE
REQUIRED BY ACI 301.
3. DO NOT USE FROZEN MATERIALS OR MATERIALS CONTAINING ICE OR
SNOW.
4. DO NOT PLACE CONCRETE IN CONTACT WITH SURFACES LESS THAN 35
DEG F, OTHER THAN REINFORCING STEEL.
5. DO NOT USE CALCIUM CHLORIDE, SALT, OR OTHER MATERIALS
CONTAINING ANTIFREEZE AGENTS OR CHEMICAL ACCELERATORS UNLESS
OTHERWISE SPECIFIED AND APPROVED IN MIXTURE DESIGNS.
NOTE: CONTRACTOR TO SUBMIT NEW BRICK AND
MORTAR SAMPLES TO ARCHITECT PRIOR TO
ORDERING MATERIALS. MATCH EXISTING CAMPUS
BRICK AND MORTAR
NOTE: CONTRACTOR SHALL SUBMIT MAIN BODY
COLOR - PMS RED 201 SAMPLE OF COLOR AND
PANEL FINISH TO ARCHITECT FOR REVIEW PRIOR
TO ORDERING MATERIALS
COLOR 2 - WHITE. EQUAL TO 0/0/0/0
COLOR 3 - BLACK. EQUAL TO 0/0/0/100
SIGN CABINET NOTES:
1. #3003 H-14 ALUMINUM SIGN PANELS. MIN. 14
GAUGE (.064 INCH)
2. ALL SEAMS TO BE CAULKED.
3. ALL FASTENERS WILL BE GALVANIZED OF NON-
CORROSIVE
4. STRUCTURAL FRAM TO BE PAINTED PRIOR TO
EXTERIOR SKINS BEING ATTACHED (FOR RUST
PREVENTION).
5. SIGN FACES ALLOW ACCESS TO INTERNAL
LIGHTING/REPAIRS WITHOUT NEEDING TO TAKE
APART THE SIGN.
6. PROVIDE DRAINAGE HOLES IN BASE OF METAL
SIGN CABINET
/1
/2
A d d e n d u m
File details come from the government source that posted it. Updated .